首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Pralidoxime methylsulfate (Contrathion) is widely used to treat organophosphate poisoning. For the first time, we developed a specific assay for urinary pralidoxime using capillary zone electrophoresis (CZE) in the following conditions: fused-silica capillary (length: 47 cm, internal diameter: 75 microm), electrolyte solution: 25 mM sodium borate (pH 9.1), voltage: 15 kV, temperature: 25 degrees C, injection time: 1 or 2s, on-line UV detection: 280 nm. Sample preparation did not require a deproteinization step (1:5 dilution in water). The method was linear between 0.125 and 2 mg mL-1 of pralidoxime (quantification limit: 0.10 mg mL-1). Coefficients of variation for intra- and inter-assay precision were below 10% for all three control levels (0.15-1.15 mg mL-1). This assay was successfully applied to urine specimens from organophosphate poisoned patients treated by Contrathion (n=10). This CZE method allows the measure of pralidoxime in urine within 15 min with excellent precision, selectivity, and sensitivity. It is simple (no pretreatment) and convenient, thus suitable for the monitoring of Contrathion therapy in organophosphate poisoned patients.  相似文献   

2.
A sensitive liquid chromatographic method for the analysis of clarithromycin, a macrolide antibiotic, in human serum using pre-column derivatization with 9-fluorenylmethyl chloroformate (FMOC-Cl) is described. The method involved liquid-liquid extraction of the drug and an internal standard (amantadine) followed by pre-column derivatization of the analytes with FMOC-Cl. A mixture of 0.05 M phosphate buffer containing triethylamine (2 mL L(-1); pH 3.8) and methanol (17:83, v/v) was used as mobile phase and chromatographic separation was achieved on a Shimpack CLC-ODS column. The eluate was monitored by a fluorescence detector with respective excitation and emission wavelengths of 265 and 315 nm. The analytical method was linear over the concentration range of 0.025-10 microg mL(-1) of clarithromycin in human serum with a limit of quantification of 0.025 microg mL(-1). The assay is sensitive enough to measure drug levels obtained in human single dose studies. In the present method, sensitivity and run time of analysis have been improved, and successfully applied in a bioequivalence study of three different clarithromycin preparations in 12 healthy volunteers.  相似文献   

3.
Based on the sensitizing effect of formaldehyde on the chemiluminescence (CL) reaction of propylthiouracil (PTU) and methylthiouracil (MTU) with acidic potassium permanganate and the combination technique of high-performance liquid chromatography (HPLC), a sensitive, selective and simple post-column CL detection method for determining PTU and MTU is described. The optimal conditions for the CL detection and HPLC separation were carried out. The linear ranges were 0.1-20 microg mL(-1) for MTU and 0.1-10 microg mL(-1) for PTU, the detection limits were 0.03 microg mL(-1) for PTU, 0.03 microg mL(-1) for MTU and the quantification limits were 0.1 microg mL(-1) for PTU, 0.1 microg mL(-1) for MTU. The method has been satisfactorily applied for the determination of MTU and PTU in human serum samples.  相似文献   

4.
The aim of this paper is to investigate the characteristics of atractylenolide I (AO-I) in the body by a GC-MS method. All bio-samples were cleared up with a liquid-liquid extraction procedure. The calibration curves were linear within a range of 5-1000 ng/mL for plasma samples, 0.06-16.00 microg/g for cerebellum samples, and 0.03-8.00 microg/g for other tissue samples. The limit of quantification (LOQ) for AO-I was 1.0 ng/mL or 1.0 ng/g (S/N>micro=10) in the bio-samples. In the applications, the main pharmacokinetic parameters were firstly obtained as follows: Tmax=0.37+/-0.19 h, Cmax=0.26+/-0.05 microg/mL, AUC=1.95+/-0.30 microgh/mL and ka=10.08+/-5.60 h(-1). The tissue distribution of AO-I in rats after the oral administration of 50.0mg/kg was from 0.225 to 0.031microg/g with a decreasing tendency in different tissues like liver>kidney>spleen>cerebellum>heart>cerebrum>lung. The protein binding in rat plasma, human plasma and bovine serum albumin was 80.8+/-3.9, 90.6+/-3.1 and 60.9+/-5.1%, respectively.  相似文献   

5.
A resonance light scattering (RLS) detection method for protein was developed, using a flow-injection system based on the enhancement of RLS signals from Biebrich scarlet (BS) by protein. The enhanced RLS intensities at 286.0 nm, in acidic aqueous medium, were proportional to the protein concentration over the range 0.005-18 microg/mL and 0.008-16 microg/mL for human serum albumin (HSA) and bovine serum albumin (BSA), respectively, with corresponding limits of detection (3sigma) of 5.00 ng/mL for HSA, and 7.80 ng/mL for BSA. The method was successfully applied to the quantification of total proteins in human serum samples.  相似文献   

6.
A rapid, selective and sensitive HPLC assay has been developed for the routine analysis of amoxicillin in rat plasma, gastric juice aspirate and gastric tissue which is applicable to low concentrations of amoxicillin (<1 microg mL(-1)) or small sample volumes. Amoxicillin was converted, via an internal rearrangement, to form a fluorescent product which was subsequently recovered using liquid-liquid extraction. A Kromasil ODS 3 microm (150 x 3.2 mm I.D.) column was maintained at 40 degrees C and used with a mobile phase consisting of methanol-water (55:45, v/v). Fluorimetric detection was at an lambda(ex) of 365 nm and an lambda(em) of 445 nm. The limits of quantitation for amoxicillin were 0.1 microg mL(-1) for gastric juice aspirate (500 microL), 0.5 microg mL(-1) for plasma (50 microL) and 0.075 microg g(-1) for gastric tissue (250 mg). The method was linear up to at least 15 microg mL(-1) in gastric juice aspirate, up to 200 microg mL(-1) in plasma and up to 100 microg g(-1) in gastric tissue, with inter- and intra-day RSDs being less than 19%. The assay has been applied to the measurement of amoxicillin in rat plasma, gastric juice aspirate and gastric tissue for pharmacokinetic studies in individual rats.  相似文献   

7.
The glycoprotein UDP-N-acetylglucosamine: beta-D-mannoside-1,4-N-acetylglucosaminyltransferase-III (GnT-III) catalyzes the addition of N-acetylglucosamine via a beta-1, 4-linkage to the beta-linked mannose of the trimannosyl core of N-linked glycans. It has been reported that the expression of GnT-III increases in many oncogenically transformed cells and human hepatocellular carcinoma (HCC) tissues, and GnT-III enzyme activity in serum can be used for the detection and monitoring of primary hepatomas and hepatocellular carcinomas. A solid-phase enzyme-linked immunosorbent sandwich assay in which a polyclonal antibody (PAb) to aglycosylrecombinant GnT-III (AGR-GnT-III) and a monoclonal antibody (mAb) are employed as a capture protein and probe protein, respectively, is described. The sensitivity of the PAb-mAb sandwich assay, as determined by the dose-response effect for AGR-GnT-III, was 10 ng/ml. This assay was specific for GnT-III and did not detect beta-1, 6-N-acetylglucosaminyltrasferase-V (GnT-V). AGR-GnT-III concentrations in 377 serum specimens were determined by the PAb-mAb sandwich assay and the results were analyzed based on the disease category, using 1.99 microg/mL (AGR-GnT-III) as a cut-off value. The AGR-GnT-III level of 61 normal serum samples was 0.57 +/- 0.71 microg/ml (mean +/- SD). The results revealed an elevation in serum AGR-GnT-III levels in 60 of 86 patients (3.03 +/- 2.04 microg/ml) with liver cirrhosis (LC) and 86 of 91 patients (2.73 +/- 0.59 microg/ml) with chronic hepatitis (CH). By contrast, 3 of 61 normal subjects, 9 of 34 patients (1.02 +/- 1.03 microg/ml) with acute hepatitis and 8 of 38 patients (1.79 +/- 0.56 microg/ml) with a variety of non-hepatic diseases exhibited a slight increase above the cut-off value. These results indicate that serum AGR-GnT-III levels are elevated predominantly in LC or CH cases. Serum AGR-GnT-III concentration, as measured by the developed PAb-mAb sandwich assay, may be a useful differential marker as a diagnostic aid for CH and/or LC and warrants further investigations with expanded serum panels.  相似文献   

8.
A rapid, simple, accurate, and precise reverse-phase high-performance liquid chromatography (HPLC) method for measuring sparfloxacin in human serum was improved, validated, and applied to determine the influence of polymorphisms in MDR1 (exons 12, 21, and 26) gene on sparfloxacin pharmacokinetics. Sparfloxacin and an internal standard, ciprofloxacin, were extracted from human serum by protein precipitation with dilution and analyzed on a Luna C(18) 5-microm column in a mobile phase of acetonitrile-0.035 M perchloric acid (28:72, v/v, adjusted to pH 2.0 with 0.015 M triethylamine) and UV detection at 300 nm. This analysis was performed at three different laboratories using the same quality control (QC) samples. The chromatograms showed good resolution, sensitivity, and no interference by human serum. The method showed linear responses over a concentration range of 0.05-2 microg/ml, with correlation coefficients of greater than 0.999 at the three laboratories. Intra- and inter-day assay precision and accuracy fulfilled international requirements. The mean absolute recovery for human serum was 98.8+/-5.7%. Sparfloxacin in human serum was stable during storage and the assay procedure. The lower limit of quantification using 0.2 ml of serum was 0.05 microg/ml, which was sensitive enough for pharmacokinetic studies. This method was used to study the pharmacokinetics of sparfloxacin in human volunteers, following a single oral administration of sparfloxacin (100 mg) two tablets at three different laboratories. MDR1 polymorphisms did not significantly (P < 0.01) affect the pharmacokinetic parameters (AUC and C(max)) of sparfloxacin.  相似文献   

9.
The bioactive constituent, glycyrrhizin or glycyrrhizic acid (GA), was purified from two traditional Chinese medicines (TCM), Shaoyao gancao tang and Dahuang gancao tang, and from crude extracts from licorice roots by means of immunoaffinity chromatography using anti-GA monoclonal antibody (MAb) and was quantified with an enzyme-linked immunosorbent assay (ELISA). Laboratory preparations included the synthesis of conjugate GA-human serum albumin (GA-HSA), the production of anti-GA-MAb, the optimization of the immunoaffinity column packed with the anti-GA-MAb coupled to hydrazide gel and the determination of the GA content in TCM and crude drugs from five different sources by ELISA and high performance liquid chromatography (HPLC). The experimental results reveal that the anti-GA-MAb coupled to Affi-Gel Hz gel results in a coupling efficiency of 95.2%, and the immunoaffinity chromatography gives a mean recovery of 97.6% of GA with a capacity of 33.5+/-2.40 microg/mL of immunoaffinity gel under the given conditions. The GA content of the crude extracts (ranging 74.8-114.6 microg/mg) from different sources by the ELISA method is much greater than that of the TCM (16.4-25.1 microg/mg) which is, in good agreement with the results of the HPLC method. Our report provides a rapid, reliable and sensitive approach for one-step separation and quantification of GA.  相似文献   

10.
The interactions between 1-benzoyl-4-p-chlorphenyl thiosemicarbazide (BCPT) and bovine serum albumin (BSA) or human serum albumin (HSA) have been studied by fluorescence spectroscopy. By the analysis of fluorescence spectrum and fluorescence intensity, it was showed that BCPT has a strong ability to quench the intrinsic fluorescence of both bovine serum albumin and human serum albumin through a static quenching procedure. The binding constants of BCPT with BSA or HSA were determined at different temperatures based on the fluorescence quenching results. The binding sites were obtained and the binding force were suggested to be mainly hydrophobic. The effect of common ions on the binding constants was also investigated. A new fluorescence spectroscopy assay of the proteins is presented. The linear range is 5.36-67.0 microg mL(-1) with recovery of 101.1% for BSA, and the linear range is 8.28-144.9 microg mL(-1) with recovery of 102.6% for HSA. Determination of the proteins in bovine serum or in human serum by this method gives results which are very close to those obtained by using Coomassie Brilliant Blue G-250 colorimetry. A practical method was proposed for the determination of BCPT in human serum samples.  相似文献   

11.
A simple, fast, and sensitive high performance liquid chromatographic (HPLC) assay was developed for quantitation of lamivudine in human serum. Lamivudine is polar compound and its extraction from the human serum in previously published HPLC methods involved either protein precipitation or solid phase extraction techniques. However, existence of endogenous peaks which interfere with the drug or appeared as late eluting peaks and lead to long run time of analysis has been reported. Application of either an ion pairing agent in the mobile phase or time consuming column purge has been used in the published methods. Present paper describes liquid - liquid extraction of lamivudine and internal standard (famotidine) using dichloromethane-isopropyl alcohol (1:1, v/v) as an extracting solvent and salting out approach. The mobile phase was a mixture of phosphate buffer (0.05 M) containing triethylamine (1 mL/L, v/v; pH 3.5) and methanol (91:9, v/v) at a flow rate of 2.2 mL/min. The analysis was performed on a column (150 mm x 6 mm i.d.) which was packed with 5 microm particles of ODS packing material. Under these conditions no interference in the assay from any endogenous substance was observed. The limit of quantification was evaluated to be 5 ng/mL. Accuracy and precision of the method were also studied and the technique was shown to be selective and linear into the concentration range of 5-2500 ng/mL. This method has been used in two randomized crossover bioequivalence studies of 100 and 150 mg lamivudine preparations in 12 and 24 healthy volunteers, respectively.  相似文献   

12.
Compound Danshen Dripping Pill (CDDP) is an important drug widely used for the treatment of cardiovascular diseases. An active component Danshensu (DS) of CDDP was separated by reversed-phase high performance liquid chromatography using column-switching system and analyzed by electrospray mass spectrometry. With this validated assay the pharmacokinetics of CDDP was studied in 10 healthy volunteers after a single oral administration of 250 mg. After trichloroacetic acid precipitation of serum proteins, the analytes were preconcentrated and black-flushed on a reversed-phase column for separation using a switching valve. The analytes were ionized using negative electrospray ionization (ESI) mode. The precursor ion of m/z 196.6 was used to quantify DS in serum. The linear calibration curve ranged from 1.25 to 175 microg/mL. The limit of quantification (LOQ) for DS was 0.15 microg/mL. The intra-day and inter-day precision (R.S.D.) was less than 7.4 and 7.9%, respectively.  相似文献   

13.
As a continuation of the recently communicated discovery of oximinoarylsulfonamides as potent inhibitors of HIV-1 aspartyl protease, compounds bearing pyridylmethyl substituents at P3 were designed and synthesized. Potent analogs in this series provided low single-digit nanomolar EC50 values against both wild-type HIV and resistant mutant virus (A17), attenuated some 3- to 12-fold in the presence of 50% human serum. Pharmacokinetic results for compounds in this series showed good to excellent exposure when co-administered orally with an equal amount of ritonavir (5mg/kg each) in the rat, with average AUC >8 microg h/mL. Similar dosing in dog resulted in significantly lower plasma levels (average AUC <2 microg h/mL). The 3-pyridylmethyl analog 30 gave the best overall exposure (rat AUC=7.1 microg h/mL and dog AUC=4.9 microg h/mL), however, this compound was found to be a potent inhibitor of cytochrome P450 3A (Ki=2.4 nM).  相似文献   

14.
采用ELISA法建立检测恒河猴血清中trastuzumab的酶联免疫竞争法,为研究人体内trastuzumab的药物动力学学和药效学提供依据。方法的测量范围是1~100μg/mL,最低检测限为1.0μg/mL。板内精密度范围91%~107%,相对标准偏差为1.5%~4.9%。板间精密度范围102%~110%,相对标准偏差为2.7%~15.4%。方法中未显示与重组人Ⅱ型肿瘤坏死因子受体-抗体融合蛋白、重组抗CD20单克隆抗体、丙种球蛋白等的交叉反应。此方法的特异性、灵敏度、精密度和准确度均满足恒河猴血清样品的分析,是检测猴和人体内trastuzumab的理想方法。  相似文献   

15.
Sensitive quantification method for fat-soluble vitamins in human breast milk by liquid chromatography-tandem mass spectrometry was developed. Vitamins A, D and E were extracted from 10.0 mL of breast milk after saponifying by basic condition. Vitamin K derivatives were extracted from 3.0 mL of breast milk after lipase treatment. The corresponding stable isotope-labeled compounds were used as internal standards. For the determination of vitamin D compounds, derivatization with a Cookson-type reagent was performed. All fat-soluble vitamins were determined by liquid chromatography-tandem mass spectrometry in the positive ion mode. The detection limits of all analytes were 1-250 pg per 50 microL. The recoveries of fat-soluble vitamins were 91-105%. Inter-assay CV values of each vitamin were 1.9-11.9%. The mean concentrations of retinol, vitamin D3, 25-hydroxyvitamin D3, alpha-tocopherol, phylloquinone and menaquinone-4 were 0.455 microg/mL, 0.088 ng/mL, 0.081 ng/mL, 5.087 microg/mL, 3.771 ng/mL, and 1.795 ng/mL, respectively (n=82). This method makes possible to determine fat-soluble vitamins with a wide range of polarities in human breast milk. The assay may be useful for large-scale studies.  相似文献   

16.
Thalidomide is a racemate with potentially different pharmacokinetics and pharmacodynamics of the component (+)-(R)- and (-)-(S)-thalidomide enantiomers. As part of a project on the adjunctive effects of thalidomide and cytotoxic agents, a method for the chiral separation and quantitation of thalidomide was developed and validated. Thalidomide in relevant serum and tissue homogenate samples was stabilized by buffering with an equal volume of citrate-phosphate buffer (pH 2, 0.2M), and stored at -80 degrees C pending assay. The thalidomide enantiomers, extracted from the samples with diethyl ether, were well separated on a chiral HPLC column of vancomycin stationary phase and a mobile phase of 14% acetonitrile in 20 mM ammonium formate adjusted to pH 5.4; their concentrations were determined with phenacetin as internal standard at 220 nm detection. Over a thalidomide concentration range of 0.1-20 microg/ml, assay precision was 1-5% (CV) for both enantiomers, and calibration curves were linear with all correlation coefficients being >0.99. The estimated limit of quantification for both enantiomers was 0.05 microg/ml with 0.2-0.6 ml serum samples. Thalidomide in rat and human serum, acidified and stored as described above, was found to be chemically and chirally stable over 1 year. The method has been successfully applied to serum samples from human patients undergoing thalidomide treatment for mesothelioma, and to serum, blood and tissue samples from a laboratory rodent model using transplanted 9l gliosarcoma. Enantioselectivity in thalidomide pharmacokinetics has been found, thereby reinforcing the need for considering the relevance of chirality in thalidomide pharmacology.  相似文献   

17.
A sensitive and rapid method is described for determination of clopidogrel carboxylic acid (CCA), the inactive metabolite of anti platelet agent, clopidogrel, in human serum. The analytical procedure involves liquid-liquid extraction of the analyte and an internal standard (phenytoin) with ethyl acetate. A mobile phase consisting of 0.05 M phosphate buffer containing triethylamine (0.5 mL/L; pH 5.7) and acetonitrile (56:44 v/v) was used and chromatographic separation was achieved using C18 analytical column at detector wavelength of 220 nm. The calibration curves were linear over a concentration range of 0.05-10 microg/mL of CCA in human serum. The total run time of analysis was 5.5 min and the lower limits of detection (LOD) and quantification (LOQ) were 0.02 and 0.05 microg/mL, respectively. The method validation was carried out in terms of specificity, sensitivity, linearity, precision, accuracy and stability. The validated method was applied in a randomized cross-over bioequivalence study of two different clopidogrel preparations in 24 healthy volunteers.  相似文献   

18.
A simple rapid piezoelectric immunoagglutination assay (PEIA) technique with antibody-modified liposome has been developed for direct quantitative detection of human immunoglobulin G (hIgG). This technique is based on specific agglutination of antibody-coated liposome particles in the presence of the corresponding antigen, which can be monitored by the frequency shift of a piezoelectric device. Compared with conventional piezoelectric assays, this liposome-based PEIA does not require the immobilization of antigen or antibody on the quartz crystal surface, making the developed technique especially useful for rapid and renewable immunochemical determination. To alleviate non-specific adsorption of serum proteins, modification of the quartz crystal surface by different protocols and the composition of the assay medium have been investigated. The results indicate that the background interference can be substantially minimized through modifying the quartz crystal surface with a bovine serum albumin (BSA) layer and introducing an appropriate amount of BSA in the assay medium. The effects of the liposome composition, the liposome concentration and the concentration of poly(ethylene glycol) (PEG) in the assay medium, have also been investigated. The frequency responses of the liposome-based PEIA are linearly correlated to hIgG concentration in the range of 0.05-6 microg mL(-1) with a detection limit of 50 ng mL(-1).  相似文献   

19.
A rapid, sensitive and specific method was developed for the quantification of valacyclovir and acyclovir in human plasma. Sample preparation was performed by protein precipitation with acetonitrile followed by filtration. Valacyclovir, acyclovir and ganciclovir (internal standard) were separated isocratically on a reversed-phase porous graphitized carbon analytical column (2.1 mm x 125.0 mm i.d., particle size 5 microm), using a mobile phase of acetonitrile/water with 0.05% (v/v) diethylamine (50:50, v/v) at a flow rate of 0.15 mL min(-1) in 4.0 min. Detection was performed by negative electrospray ionization using the selected ion monitoring mode of the deprotonated molecular ions at m/z 323.0 for valacyclovir, 224.0 for acyclovir and 254.0 for ganciclovir. The assay had linear calibration curves over the range 0.020-0.800 microg mL(-1) for valacyclovir and 0.100-20.00 microg mL(-1) for acyclovir. Accuracy and precision were within the acceptance limit of 15%. The method was successfully applied to the analysis of plasma samples obtained from patients after oral administration of valacyclovir.  相似文献   

20.
Iodixanol is a widely used iso-osmolar contrast medium agent. Similar to iohexol, it can also be a good exogenous marker for the measurement of glomerular filtration rate (GFR). This article describes the development and validation of an HPLC-UV method for quantification of iodixanol in human plasma. Internal standard, iohexol (20 microl, 1 mg/ml), and perchloric acid (30 microl, 20%, v/v) were added to plasma samples (300 microl), followed by neutralization with 10 microl potassium carbonate (5M). Samples were centrifuged and 10 microl of the supernatant was injected onto a C(18) EPS analytical column (3 microm particle size, 150 mm x 4.6 mm). The extraction method yielded >95% recovery for both iodixanol and iohexol. The mobile phase consisted of 0.1% (w/v) sodium formate buffer and acetonitrile. Iohexol and iodixanol peaks were eluted at approximately 5 and 9 min, respectively using a fast gradient method. The assay lower limit of detection was 2.0 microg/ml and lower limit of quantification was 10 microg/ml. The calibration curves, assessed in six replicates, were linear over an iodixanol concentration range of 10-750 microg/ml. Intra- and inter-day accuracy was >95% and precision expressed as % coefficient of variation was <10%. This method is simple, accurate, precise and robust and can potentially be used for iodixanol quantification in large-scale clinical studies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号