首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 27 毫秒
1.
We present the results of a collaborative study for the characterization of a preparation of diphtheria toxoid adsorbed, and its calibration in terms of the 3rd International Standard (IS) for Diphtheria Toxoid Adsorbed. Calibration was performed using established World Health Organization (WHO) and European Pharmacopoeia (Ph. Eur.) protection models. Two candidate toxoid preparations were included in the study, one of which was adopted as a replacement Ph. Eur. Biological Reference Preparation (BRP, batch 4) in February 2009. The second candidate preparation was found to have a unitage of 213 IU/ampoule based on the calibration by in vivo bioassay in 19 laboratories in 16 countries, and was established as the 4th IS for Diphtheria Toxoid Adsorbed by the WHO Expert Committee on Biological Standardization (ECBS) in October 2009.The study also assessed performance of the replacement standard in mouse and guinea pig serological assays which are used as alternative procedures for diphtheria potency testing. Participants tested both candidate preparations and potency was expressed in relative terms only. Results suggest that the replacement standard is suitable for use as the reference vaccine in serological assays and that the Vero cell assay may be suitable for calibration of future replacement standards.  相似文献   

2.
Here we report the characterisation of a preparation of tetanus toxoid, adsorbed, and its calibration by 27 laboratories in 19 countries in a joint international collaborative study co-sponsored by World Health Organization (WHO) Expert Committee of Biological Standardization (ECBS) and the European Biological Standardisation Programme of European Directorate for the Quality of Medicines (EDQM), Council of Europe. Calibration was in terms of the Second International Standard (I.S.) for Tetanus Toxoid, Adsorbed, by the established WHO/European Pharmacopoeia (Ph Eur) challenge methods. The replacement standard preparation was found to have a unitage of 469 IU/ampoule on the basis of its calibration in guinea-pigs and 496 IU/ampoule on the basis of its calibration in mice. Assessment, both within the collaborative study and as part of candidate characterisation, indicated satisfactory stability of the candidate preparation. This study also provided some information on the effect of mouse strain on potency testing of tetanus vaccines. A limited assessment of the impact of the replacement standard on testing of current production batches of vaccines was also carried out by four manufacturers. This study did not directly address the serological approaches to potency testing. However, one laboratory offered data from mouse serology assay, which gave comparable estimates to in vivo mouse bioassay.Based on the results of this study and with the agreement of participants, the candidate standard was established as the Third International Standard for Tetanus Toxoid, Adsorbed (coded 98/552) by the WHO Expert Committee of Biological Standardization (ECBS) in November 2000. The same preparation was also established as the second Ph Eur Biological Reference Preparation (Ph Eur BRP, batch no. 2) by the Steering Committee of the Biological Standardisation Programme of the EDQM and approved by the European Pharmacopoeia Commission.  相似文献   

3.
We report here the characterisation of a preparation of diphtheria toxoid, adsorbed, and its calibration by twenty laboratories in fourteen countries in terms of the Second International Standard (I.S.) for Diphtheria Toxoid, Adsorbed, coded sample A (DIXA) using the established World Health Organisation (WHO)/European Pharmacopoeia (Ph Eur) challenge methods. The replacement standard preparation was found to have a unitage of 160 IU/ampoule on the basis of its calibration by in vivo bioassay. Stability was assessed within the collaborative study, and as part of candidate characterisation. Results suggest that the replacement standard will have satisfactory stability. This study also provided an opportunity to investigate serology as alternative to in vivo bioassay for potency testing of diphtheria vaccines. Six laboratories participated by performing serology according to in-house protocol. The calibration of the replacement standard in a mouse Vero cell assay gave a significantly higher results than in the established WHO/Ph Eur methods. Based on the results of this study and with the agreement of participants, the candidate standard was established as the Third International Standard for Diphtheria Toxoid, Adsorbed (coded 98/560) by the WHO Expert Committee of Biological Standardization in October 1999. The same preparation was also established as the second Ph Eur Biological Reference Preparation (Ph Eur BRP, batch no. 3) by the Steering Committee of the Biological Standardisation Programme of the European Directorate for the Quality of Medicines and approved by the European Pharmacopoeia Commission.  相似文献   

4.
The 1st International Reference Reagents (IRR) of Diphtheria and Tetanus Toxoids for Flocculation Test (DIFT and TEFT) were established by the WHO in 1988. These reagents are essential for the standardization of assays used to calculate Lf units of toxoids. Candidate replacement materials were provided by several European vaccine manufacturers and were formulated and freeze-dried at NIBSC. This paper provides a summary of the results of an international collaborative study including 18 laboratories from 16 countries, which examined the candidate replacement materials in a variety of methods. Materials 02/176 and 04/150 were proposed and adopted by the Expert Committee on Biological Standardization of WHO in October 2007 as 2nd WHO International Standards of Diphtheria and Tetanus Toxoid for use in Flocculation Test. The replacement standards were assigned the value of 1100 and 690Lf/ampoule, respectively, based on results of flocculation tests carried out using provided reagents. Material coded 02/176 fully complied with the WHO specifications for stability, residual moisture content, precision of fill and sterility. Stability of material coded 04/150 was slightly lower than expected but predictions were based only on 2-year data and were to be further monitored, post-adoption.  相似文献   

5.
Due to the increase in the number of infliximab products, the need for global harmonization of the bioactivity of this monoclonal antibody was recognized by the World Health Organization (WHO). In response, the National Institute for Biological Standards and Control (NIBSC) developed the first international standard (IS) for infliximab, which targets tumour necrosis factor (TNF). Each ampoule is assigned values of 500 IU of TNF neutralizing activity and 500 IU of binding activity. Two preparations of infliximab were formulated and lyophilized at NIBSC prior to evaluation in a collaborative study for their suitability to serve as an IS for the in vitro biological activity of infliximab. The study involved participants using in vitro cell-based bioassays (TNF neutralization, antibody-dependent cell-mediated cytotoxicity and complement-dependent cytotoxicity) and binding assays. The results of this study showed that the candidate preparation, coded 16/170, is suitable as an IS for infliximab bioactivity. This infliximab IS from NIBSC, is intended to support in vitro bioassay calibration and validation by defining international units of bioactivity. The proposed unitages, however, are not intended to revise product labelling or dosing requirements, as any decisions regarding this relies solely with the regulatory authorities. Furthermore, the infliximab IS is not intended for determining the specific activity of products, nor to serve any regulatory role in defining biosimilarity. We briefly discuss the future use of WHO international standards in supporting the global harmonisation of biosimilar infliximab products.  相似文献   

6.
Tetanus toxoid is a vital primary reference material used for standardization of assays required to establish the antigenic purity of tetanus toxoid for vaccine production. Several formulations were assessed and ampouled fills of each formulation lyophilised. The relative Lf content determined by Ramon flocculation, SRD, and ELISA assays was measured. The stability of the tetanus toxoid activity in each formulation was assessed by accelerated degradation studies. Formulations containing glycine were not suitable in flocculation tests but both sorbitol and trehalose formulations were. The trehalose/sodium chloride formulation had a good appearance, showed good activity in all assays and maintained its activity best under stress conditions. This formulation has been applied to a large scale batch of ampoules prepared as a WHO candidate replacement standard, evaluated in a collaborative study and accepted as a replacement WHO IS for use in flocculation test (WHO ECBS, October 2007, ref no BS/07.2061). The stability of this formulation was also excellent for the large scale batch. The benefits of using thermal analysis and freeze drying microscopy coupled with small scale lyophilisation trials in order to screen formulations for the preparation of batches of biological reference materials are demonstrated.  相似文献   

7.
J Lyng 《Biologicals》1990,18(1):11-17
The Lf-unit, which is used in the control of diphtheria and tetanus toxoid production and in some countries also to follow immunization of horses for production of antitoxins, has hitherto been defined by means of antitoxin preparations. A diphtheria toxoid and a tetanus toxoid preparation, both freeze-dried, were examined in an international collaborative study for their suitability to serve as reference reagents in the flocculation tests and for defining the Lf-units. It was shown that flocculation tests using the reference toxoids are very reproducible and reliable and the WHO Expert Committee on Biological Standardization established: the toxoid called DIFT as the International Reference Reagent of Diphtheria Toxoid for Flocculation Test with a defined content of 900 Lf-units of diphtheria toxoid per ampoule; and the toxoid called TEFT as the International Reference Reagent of Tetanus Toxoid for Flocculation Test with a defined content of 1000 Lf-units of diphtheria toxoid per ampoule.  相似文献   

8.
Whole cell pertussis vaccine is still widely used in many countries. An International Standard is needed for its potency control. The Third International Standard for Pertussis Vaccine was prepared about 40 years ago and its replacement was recommended by the Expert Committee for Biological Standardisation (ECBS) of the WHO. Material in ampoules coded 94/532 was prepared as a candidate replacement and has been evaluated in international collaborative studies which consisted of two parts. The first part, to assess the suitability of the candidate standard by comparing it with the Second International Standard for Pertussis Vaccine (IS2) involved 14 laboratories in 11 countries. The second part to compare the candidate standard with the Third International Standard for Pertussis Vaccine (IS3) involved 16 laboratories in 14 countries. Since 1995 various other studies have included the international standards and the results of these are also considered in assessing likely continuity of the IU for potency of whole cell pertussis vaccine. The preparation in ampoules coded 94/532 was adopted by the WHO ECBS in October 2006 as the 4th International Standard for whole cell pertussis vaccine and assigned an activity of 40 IU per ampoule on the basis of the studies reported here.  相似文献   

9.
Yellow fever vaccines are routinely assayed by plaque assay. However, the results of these assays are then converted into mouse LD(50) using correlations/conversion factors which, in many cases, were established many years ago. The minimum required potency in WHO Recommendations is 10(3) LD(50)/dose. Thirteen participants from 8 countries participated in a collaborative study whose aim was to assess the suitability of two candidate preparations to serve as an International Standard for yellow fever vaccine. In addition, the study investigated the relationship between the mouse LD(50) test and plaque forming units with a view to updating the WHO recommendations. Plaque assays were more reproducible than mouse assays, as expected. Differences in sensitivities of plaque assays were observed between laboratories but these differences appear to be consistent within a laboratory for all samples and the expression of potency relative to the candidate standard vaccine improved the reproducibility of assays between laboratories. However, the use of potencies had little effect on the between laboratory variability in mouse LD(50) assays. There appears to be a consistent relationship between overall mean LD(50) and plaques titre for all study preparations other than sample E. The slope of the correlation curve is >1 and it would appear that 10(3) LD(50) is approximately equivalent to 10(4) plaque forming units (PFU), based on the overall means of all laboratory results. The First International Standard for yellow fever vaccine, NIBSC Code 99/616, has been established as the First International Standard for yellow fever vaccine by the Expert Committee of Biological Standards of the World Health Organisation. The International Standard has been arbitrarily assigned a potency of 10(4.5) International Units (IU) per ampoule. Manufacturers and National Control Laboratories are including the First International Standard for yellow fever vaccine in routine assays so that the minimum potency in IU of vaccines released for use and which meet the current minimum potency of 10(3) LD(50) in mouse assays, can be determined. These data will be analysed before a review of the WHO requirements, including the minimum potency per dose, is undertaken.  相似文献   

10.
A collaborative study was designed to asses two freeze-dried human plasma preparations containing anti-Treponema pallidum antibodies, 05/132 and 05/122, for their suitability as international reference reagents for syphilis serology. Both preparations are intended as replacements of the first international standard (IS) for syphilitic serum antibodies (HS). Samples were tested by eight laboratories using the T. pallidum passive particle agglutination assay (TPPA), the venereal disease research laboratory test (VDRL) and the rapid plasma reagin test (RPR). In addition a range of immunoassays was also used. The outcome of the collaborative study revealed that candidate standard 05/132 contains T. pallidum-specific IgG and IgM and is reactive in VDRL or RPR, and that 05/122 contains T. pallidum-specific IgG but is not reactive in either the VDRL or RPR test. Both 05/132 and 05/122 are reactive in the TPPA. On the basis of these results the Expert Committee on Biological Standardization of the World Health Organization designated 05/132 as the 1st IS for human syphilitic plasma IgG and IgM with a unitage of 3 IU per ampoule relative to HS and 05/122 as the 1st IS for human syphilitic plasma IgG with a unitage of 300 mIU per ampoule relative to 05/132.  相似文献   

11.
A collaborative study was carried out to assess the suitability of a candidate replacement material for the International Standard for hepatitis A immunoglobulin, which was found to be reactive for HCV RNA, and to calibrate it in International Units. The candidate standard, coded 97/646, was derived from a bulk of 16% immunoglobulin supplied by the Central Laboratory of the Netherlands Red Cross, Amsterdam, and diluted 1 in 2 in H2O resulting in a final immunoglobulin concentration of 8%. Sixteen laboratories from 11 countries participated in the study and contributed data from 64 assays performed using six commercial assay kits and four in-house methods. All assays were analysed as parallel line bioassays comparing assay response with log concentration. The overall mean potency of the candidate replacement immunoglobulin standard, 97/646, relative to the International Standard for hepatitis A immunoglobulin, was 98.6 IU/ml. A freeze-dried serum preparation, 97/648, was also calibrated in this study and had a potency of 22.64 IU/ml. The Second International Standard for hepatitis A immunoglobulin, human, was established by the World Health Organisation Expert Committee on Biological Standardisation in 1998 with a potency of 49 IU per ampoule when reconstituted in 0.5 ml.  相似文献   

12.
吸附无细胞百、白、破混合制剂(DTacP)于1995年6月至1997年9月在广东省4个市和陕西省大荔县进行了Ⅲ期临床人体接种反应和血清学效果观察,全程基础免疫婴幼儿64961例,加强注射38860例,总计为103821例,接种反应轻微,未发现有严重异常反应者。DTacP在基免后1年和加强注射前抗PT和抗FHA的抗体水平分别为101EU/ml和513EU/ml;加强注射后1个月,抗PT和抗FHA的抗体水平显著增长,分别为2434EU/ml和3113EU/ml;加强免疫后1年,抗PT和抗FHA的抗体水平均能维持在较高的抗感染水平,分别为201EU/ml和586EU/ml;DTacP抗白喉和抗破伤风的抗体水平,不论是在基免后还是在加强注射后1个月或1年,其≥001HAU/ml的例数均为100%,均显著超过儿童抗白喉和抗破伤风感染要求的保护水平(001HAU/ml)。  相似文献   

13.
The potencies of therapeutic preparations of gonadotrophins of human, urinary origin, which comprise a heterogenous mix of isoforms with follicle-stimulating hormone (FSH) and luteinizing hormone (LH) bioactivities, are standardized by WHO International Standards (IS). We report here, the evaluation, through an international collaborative study, of a candidate preparation, coded 10/286, to replace the 4th IS, 98/704, for human, urinary FSH and LH (Menotrophin) which has been used for many years for the potency assignment of therapeutic preparations using bioassays. The mean FSH and LH bioactivities of 10/286, determined by in vivo bioassays in terms of 98/704, were 183 IU per ampoule (95% confidence limits 165–202) and 177 IU per ampoule (95% confidence limits 159–197), respectively.  相似文献   

14.
The mouse vaccination-challenge test, which is the most widely used method for determining the potency of inactivated rabies vaccines, is imprecise, time-consuming, and causes severe distress to the test animals. An alternative single-dose serological method has been implemented in the European Pharmacopoeia Monograph 0451 to replace the mouse challenge test for batch release. This single-dose limit method provides semi-quantitative results, but is not suitable for quantifying potency. We have now extended this serological method to a multi-dose format which allows a quantification of vaccine potency. In studies including all rabies vaccine strains relevant for Europe, we found dose-dependency for all vaccines and standard preparations. We have demonstrated that the multi-dose serological approach provides reliable quantitative potency results and is more precise than the mouse vaccination-challenge test. We have shown that adjuvanted vaccines can be calibrated against non-adjuvanted material, and that reference material can be calibrated against the International Standard. The method is therefore capable of assigning potency with the additional advantage of requiring fewer animals and reducing distress. Once the applicability of the method has been further verified in a collaborative study, it can complement the single-dose assay and eventually eliminate the need for the mouse challenge test.  相似文献   

15.
The results obtained with four laboratory tests on four candidate formulations of Clostridium welchii type C vaccine for use in man have been compared with clinical responses to the same vaccines. Quantal response assays in mice appeared to reflect the ranking of the four vaccines in human subjects better than did the guinea pig tests. They also enabled the potency of the vaccine preparations to be related to an existing International Reference Preparation. Mouse assays in which the animals received two spaced doses of vaccine prior to challenge yielded marginally more satisfactory results in terms of precision and reflection of human responses than did assays involving a single dose of vaccine.  相似文献   

16.
A collaborative study was carried out to establish a replacement for the International Standard for Rabies Vaccine, the stocks of which are exhausted. Three rabies vaccines for human use derived from different rabies virus strains and prepared on different cell culture substrates were compared with the International Standard for Rabies Vaccine using in vivo and in vitro assay methods in a collaborative study involving 14 participants. The proposed fifth International Standard (PISRAV) which was derived from the same virus strain as the present international standard preparation, the Pitman Moore (PM) strain, was found to be approximately twice as potent relative to the International Standard in immunogenicity assays as in antigenicity assays. On the other hand another vaccine, derived from the LEP strain, was considerably more potent in antigenicity assays than in immunogenicity assays. The glycoprotein of the proposed replacement standard measured in antigenicity assays appeared to be stable at +37 degrees C for 245 days, whereas the immunogenicity of the proposed replacement vaccine was sensitive to this heat treatment and the vaccine lost 66% of its immunogenic potency. The results of this study indicate that the NIH protection test should continue to form the primary basis for potency assay of rabies vaccine as glycoprotein content does not appear to correlate with immunogenic potency for different types of vaccine. The vaccine coded PISRAV has been established as the fifth International Standard for Rabies Vaccine and a potency of 16 International Units of Rabies Vaccine (based on the immunogenicity assays) assigned to the contents of each ampoule. Each ampoule has also been assigned a unitage of 10 IU of PM Rabies Virus Glycoprotein and 135 IU of PM Rabies Virus Ribonucleoprotein.  相似文献   

17.
A collaborative study was organised by the European Directorate For the Quality of Medicines (EDQM) to assess the suitability of a candidate mouse antiserum as a European Pharmacopoeia Biological reference preparation (BRP) for acellular pertussis vaccine potency testing. The candidate antiserum was obtained by immunising mice with a five-component acellular pertussis vaccine: pertussis toxin (PT), filamentous haemagglutinin (FHA), pertactin (PRN) and Fimbrial 2/Fimbrial 3 (Fim 2&3).The study has been divided into two separate phases. Phase I was a pre-qualification study including three laboratories. This phase was aimed at pre-qualifying the candidate BRP (cBRP) and at documenting the impact of differences in the antibody detection methodology enzyme linked immunosorbent assay (ELISA) procedures on results of pertussis antisera calibration versus the currently used standard US standard pertussis antiserum (mouse) Lot 1 (SPAM-1) (United States Food and Drug Administration (USFDA) reference serum) and the cBRP. As no significant difference between the antibody titres determined by using the different ELISA methodologies was found, a large-scale study enrolling 13 laboratories (Phase II) was carried out, each participant performing its in-house methodology. Its aim was to calibrate the cBRP (in terms of the SPAM-1 reference) and to demonstrate its equivalence or superiority to internal references. The study showed that there was no difference in positive sera titres expressed relative to their corresponding internal reference (homologous situation) or the proposed standard (heterologous situation) reference. The cBRP can, therefore, reliably act as replacement for the in-house reference preparations. Further analysis of the outcome of this study enabled to assign to the cBRP a potency of 39, 138, 34 and 56 ELISA unit per millilitre, respectively, to its anti-PT, anti-FHA, anti-PRN and anti-Fim 2&3 antibody contents. The cBRP has been adopted by the European Pharmacopoeia Commission at its June 2000 session as Bordetella pertussis mouse anti-serum Ph Eur. BRP batch 1.  相似文献   

18.
M Huet  E Relyveld  S Camps 《Biologicals》1992,20(1):35-43
The activity of several Tetanus Toxoids, Adsorbed, (commercial vaccines and references) were tested in mice in comparison with a standard, by a simple method, easier than the official challenge test (WHO and European Pharmacopoeia): the Tetanus Antitoxin level was titrated by agglutination of sensitized turkey red blood cells after immunization by the toxoids. Immuno-stimulation by the Pertussis component in associated vaccines was studied and the results with the conventional and the acellular Pertussis preparations were prepared. The method was also found to be suitable for Tetanus Toxoids, Non-Adsorbed, when a booster effect was used, except for the adjuvant-free polymerized antigen (POLAN) which did not require a booster, since it gave almost as good results as conventional adsorbed tetanus vaccines.  相似文献   

19.
To establish an enzyme-linked immunosorbent assay (ELISA) technique for the serological diagnosis of infections caused by Bordetella bronchiseptica (B. bronchiseptica) in guinea pigs, the authors recently assessed the usefulness of three antigen preparations derived from the bacterial cell components: sonication antigen (S-Ag), cell surface antigen (C-Ag) and lipopolysaccharide antigen (L-Ag). The use of S-Ag for ELISA resulted in the most sensitive detection of the antibody to B. bronchiseptica from guinea pig sera immunized with killed bacteria and sera derived from naturally infected guinea pigs. Like C-Ag, S-Ag was highly specific, showing no cross-reactivity with Pasteurella multocida. Assessment of antibody formations in animals with experimentally induced infection using the three antigen preparations revealed that the antibody to S-Ag was formed earlier than antibodies to the other two antigen preparations following growth of the bacterium in the lungs. These results indicate that ELISA with S-Ag as an antigen is a useful tool for the serological diagnosis of infection by B. bronchiseptica.  相似文献   

20.
The 4th International Standard (IS) for Insulin, established in 1958, consists of a mixture of relatively impure bovine and porcine insulins and is not suitable as a standard for the assay of highly purified single-species insulins presently used in the treatment of diabetes. Preparations of human, bovine and porcine crystalline insulins, representative of current highly purified therapeutic insulins, have now been studied in an international collaborative study carried out by twenty-three laboratories in fifteen countries. In the collaborative study described here, each of the three preparations was found to be suitable for use as a standard for insulin for bioassay and each was established by WHO in 1986 as an international standard. The 4th IS of Insulin bovine/porcine (code numbered 58/6) has been discontinued. Insulin preparations should now be calibrated in terms of International Units defined by the standard for the appropriate species: the International Standard for Insulin, Human, the International Standard for Insulin, Bovine, or the International Standard for Insulin, Porcine.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号