首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Ultrasound imaging has recently been used to distinguish the length changes of muscle fascicles from those of the whole muscle tendon complex during real life movements. The complicated three-dimensional architecture of pennate muscles can however cause heterogeneity in the length changes along the length of a muscle. Here we use ultrasonography to examine muscle fascicle length and pennation angle changes at proximal, distal and midbelly sites of the human gastrocnemius medialis (GM) muscle during walking (4.5 km/h) and running (7.5 km/h) on a treadmill. The results of this study have shown that muscle fascicles perform the same actions along the length of the human GM muscle during locomotion. However the distal fascicles tend to shorten more and act at greater pennation angles than the more proximal fascicles. Muscle fascicles acted relatively isometrically during the stance phase during walking, however during running the fascicles shortened throughout the stance phase, which corresponded to an increase in the strain of the series elastic elements (SEEs) (consisting of the Achilles tendon and aponeurosis). Measurement of the fascicle length changes at the midbelly level provided a good approximation of the average fascicle length changes across the length of the muscle. The compliance of the SEE allows the muscle fascicles to shorten at a much slower speed, more concomitant with their optimal speed for maximal power output and efficiency, with high velocity shortening during take off in both walking and running achieved by recoil of the SEE.  相似文献   

2.
The purpose of this study was to investigate the relationship between muscle fascicle length and sprint running performance in 37 male 100-m sprinters. The sample was divided into two performance groups by the personal-best 100-m time: 10.00-10.90 s (S10; n = 22) and 11.00-11.70 s (S11; n = 15). Muscle thickness and fascicle pennation angle of the vastus lateralis and gastrocnemius medialis and lateralis muscles were measured by B-mode ultrasonography, and fascicle length was estimated. Standing height, body weight, and leg length were similar between groups. Muscle thickness was similar between groups for vastus lateralis and gastrocnemius medialis, but S10 had a significantly greater gastrocnemius lateralis muscle thickness. S10 also had a greater muscle thickness in the upper portion of the thigh, which, given similar limb lengths, demonstrates an altered "muscle shape." Pennation angle was always less in S10 than in S11. In all muscles, S10 had significantly greater fascicle length than did S11, which significantly correlated with 100-m best performance (r values from -0.40 to -0.57). It is concluded that longer fascicle length is associated with greater sprinting performance.  相似文献   

3.
The purpose of this study was to quantify the influence of inevitable ankle joint motion during an isometric contraction on the measured change of the gastrocnemius medialis muscle (GM) architecture in vivo during the loading and the unloading phase. Sitting on a dynamometer subjects performed isometric maximal voluntary contractions as well as contractions induced by electrostimulation. Synchronous joint angular motion, plantarflexion moment, foot’s centre of pressure and real-time ultrasonography of muscle architecture changes of the GM were obtained. During the contraction the ankle joint position altered and significantly affected the change in muscle architecture. At maximal tendon force (1094 ± 323 N), the measured fascicle length overestimated the change in fascicle length due to the tendon force by 1.53 cm, while the measured pennation angle overestimated the change in pennation angle due to the tendon force by 5.5°. At the same tendon force the measured fascicle length and pennation angle were significantly different between loading and unloading conditions. After correcting the values for the change in ankle joint angle no differences between the loading and the unloading phase at the same tendon force were found. Concerning the estimation of GM fascicle length–force and pennation angle–force curves during the loading and unloading phase of an isometric contraction, these findings indicate that not accounting for ankle joint motion will produce unreliable results.  相似文献   

4.
A large inter-individual variation is seen in muscle fascicle length of the athletes but the reasons for this phenomenon are unclear. The purpose of this study was to determine whether genetic factors contribute to the variances in muscle architectural characteristics. Nine monozygous twin pairs (3 males and 6 females), mean age 23 years (range 17-40) were studied. Fascicle length, pennation angle, and muscle thickness of the medial (MG) and lateral (LG) gastrocnemius muscles were measured in vivo by B-mode ultrasound. In the LG muscle intrapair resemblance (P < 0.01) for fascicle length (r = 0.98), pennation angle (r = 0.94) and muscle thickness (r = 0.86) were observed. In MG muscle, however, there was no intrapair resemblance for fascicle length (r = 0.66, P > 0.05), although pennation angle (r = 0.73, P < 0.05) and muscle thickness (r = 0.86, P < 0.01) were significant. Mean percent intrapair difference in LG and MG muscles were 1.8% and 5.1% for fascicle length, 11.3% and 12.3% for pennation angle and 12.4% and 9.9% for muscle thickness, respectively. There is intrapair difference between muscle thickness and pennation angle in both MG (r = 0.69, P < 0.05) and LG (r = 0.70, P < 0.05) muscles. However, no significant correlation was observed for intrapair difference between muscle thickness and fascicle length in both muscles (MG, r = 0.46; LG, r = 0.40). It appears that genetic predisposition is the predominant factor for the determination of muscle fascicle length. However, a lack of intrapair resemblance in MG fascicle length raises the possibility that fascicle length may be further influenced by external environmental factors such as physical training.  相似文献   

5.
External forces from our environment impose transverse loads on our muscles. Studies in rats have shown that transverse loads result in a decrease in the longitudinal muscle force. Changes in muscle architecture during contraction may contribute to the observed force decrease. The aim of this study was to quantify changes in pennation angle, fascicle dimensions, and muscle thickness during contraction under external transverse load.Electrical stimuli were elicited to evoke maximal force twitches in the right calf muscles of humans. Trials were conducted with transverse loads of 2, 4.5, and 10 kg. An ultrasound probe was placed on the medial gastrocnemius in line with the transverse load to quantify muscle characteristics during muscle twitches.Maximum twitch force decreased with increased transverse muscle loading. The 2, 4.5, and 10 kg of transverse load showed a 9, 13, and 16% decrease in longitudinal force, respectively. Within the field of view of the ultrasound images, and thus directly beneath the external load, loading of the muscle resulted in a decrease in the muscle thickness and pennation angle, with higher loads causing greater decreases. During twitches the muscle transiently increased in thickness and pennation angle, as did fascicle thickness. Higher transverse loads showed a reduced increase in muscle thickness. Smaller increases in pennation angle and fascicle thickness strain also occurred with higher transverse loads.This study shows that increased transverse loading caused a decrease in ankle moment, muscle thickness, and pennation angle, as well as transverse deformation of the fascicles.  相似文献   

6.
ABSTRACT: BACKGROUND: Muscle fascicle pennation angle (PA) is an important parameter related to musculoskeletal functions, and ultrasound imaging has been widely used for measuring PA, but manually and frame by frame in most cases. We have earlier reported an automatic method to estimate aponeurosis orientation based on Gabor transform and Revoting Hough Transform (RVHT). METHODS: In this paper, we proposed a method to estimate the overall orientation of muscle fascicles in a region of interest, in order to complete computing the orientation of the other side of the pennation angle, but the side found by RVHT. The measurements for orientations of both fascicles and aponeurosis were conducted in each frame of ultrasound images, and then the dynamic change of pennation angle during muscle contraction was obtained automatically. The method for fascicle orientation estimation was evaluated using synthetic images with different noise levels and later on 500 ultrasound images of human gastrocnemius muscles during isometric plantarflexion. RESULTS: The muscle fascicle orientations were also estimated manually by two operators. From the results it's found that the proposed automatic method demonstrated a comparable performance to the manual method. CONCLUSIONS: With the proposed methods, ultrasound measurement for muscle pennation angles can be more widely used for functional assessment of muscles.  相似文献   

7.
The purpose of this study was to investigate the relationship between sprint performance and architectural characteristics of leg muscles in 26 female 100-m sprinters. Pennation angle and muscle thickness of the vastus lateralis (VL) and gastrocnemius medialis (GM) and lateralis (GL) muscles were measured by B-mode ultrasonography, and fascicle length was estimated. Sprinters had a significantly lower VL pennation angle, but GM and GL pennation angle was similar between sprinters and female control subjects (N = 22). There was no significant correlation between pennation angle and 100-m personal best performance. Sprinters had significantly greater absolute fascicle length in VL and GL than controls, which significantly correlated to 100-m best-record (r = -0.51 and r = -0.44, respectively). Relative fascicle length (VL and GL) were also significantly greater in sprinters than controls. However, there were no significant correlation between relative fascicle length and 100-m best-record (r = -0.36 and r = -0.29, respectively). No relationship was found between the sprint performance and fat-free mass (r = -0.26) or body mass index (r = -0.03). However, there was a significant correlation between percent (%) body fat and 100-m best-record (r = 0.62, p < 0.01). Adjusting the confounding effect of % fat, significant correlations were seen between relative fascicle length and 100-m best-record (VL; r = -0.39 and GL; r = -0.40). Absolute and relative fascicle length were similar in elite female sprinters compared with previous reported values for elite male sprinters (Kumagai et al., 2000). It was concluded that longer fascicle length is associated with greater sprinting performance in sprinters, but there is no gender differences in fascicle length for elite sprinters.  相似文献   

8.
The purpose of this study was to provide evidence on the fact that the observed decrease in EMG activity of the gastrocnemius medialis (GM) at pronounced knee flexed positions is not only due to GM insufficiency, by examining muscle fascicle lengths during maximal voluntary contractions at different positions. Twenty-two male long distance runners (body mass: 78.5+/-6.7 kg, height: 183+/-6 cm) participated in the study. The subjects performed isometric maximal voluntary plantar flexion contractions (MVC) of their left leg at six ankle-knee angle combinations. To examine the resultant ankle joint moments the kinematics of the left leg were recorded using a Vicon 624 system with 8 cameras operating at 120 Hz. The EMG activity of GM, gastrocnemius lateralis (GL), soleus (SOL) and tibialis anterior (TA) were measured using surface electromyography. Synchronously, fascicle length and pennation angle values of the GM were obtained at rest and at the plateau of the maximal plantar flexion using ultrasonography. The main findings were: (a) identifiable differences in fascicle length of the GM at rest do not necessarily imply that these differences would also exist during a maximal isometric plantar flexion contraction and (b) the EMG activity of the biarticular GM during the MVC decreased at a pronounced flexed knee-joint position (up to 110 degrees ) despite of no differences in GM fascicle length. It is suggested that the decrease in EMG activity of the GM at pronounced knee flexed positions is due to a critical force-length potential of all three muscles of the triceps surae.  相似文献   

9.
The purposes of this study were: (a) to quantify the influence of passive ankle and knee joint angular displacement on the estimated mechanical and architectural properties of the gastrocnemius medialis (GM) muscle-tendon unit, and (b) to determine the strain distribution of separate structures (tendon, aponeurosis and fascicle) during passive lengthening of the GM muscle-tendon unit at rest. Ten male subjects participated in the study. The passive ankle and knee joint movements were performed on an isokinetic dynamometer. The kinematics of the left leg were recorded using the Vicon 624 system with 8 cameras. Two ultrasound probes were used to examine the elongation of the tendon, the aponeurosis, the fascicles and the angle of pennation of the GM. To calculate the elongation of the GM muscle-tendon unit the Achilles tendon path was reconstructed using a series of small reflective markers. The results show that the passive ankle joint angular displacement has a considerable influence on the elongation of the tendinous and architectural structures of the GM muscle-tendon unit. In contrast, the influence of knee joint angular displacement on the GM fascicle length and pennation angle becomes relevant only at knee angles greater than 144 degrees . The contribution of the tendon to the elongation of the GM muscle-tendon unit at rest is relevant because of its greater resting length in comparison to the resting length of the GM fascicles. The results indicate the existence of slackness in the inactive GM muscle-tendon unit between 121 degrees and 107 degrees ankle angle and between 65 degrees and 144 degrees knee angle.  相似文献   

10.
Fascicle curvature of human medial gastrocnemius muscle (MG) was determined in vivo by ultrasonography during isometric contractions at three (distal, central, and proximal) locations (n = 7) and at three ankle angles (n = 7). The curvature significantly (P < 0.05) increased from rest to maximum voluntary contraction (MVC) (0.4-5.2 m(-1)). In addition, the curvature at MVC became larger in the order dorsiflexed, neutral, plantar flexed (P < 0.05). Thus both contraction levels and muscle length affected the curvature. Intramuscular differences in neither the curvature nor the fascicle length were found. The direction of curving was consistent along the muscle: fascicles were concave in the proximal side. Fascicle length estimated from the pennation angle and muscle thickness, under the assumption that the fascicle was straight, was underestimated by ~6%. In addition, the curvature was significantly correlated to pennation angle and muscle thickness. These findings are particularly important for understanding the mechanical functions of human skeletal muscle in vivo.  相似文献   

11.
Ultrasound shear wave elastography is becoming a valuable tool for measuring mechanical properties of individual muscles. Since ultrasound shear wave elastography measures shear modulus along the principal axis of the probe (i.e., along the transverse axis of the imaging plane), the measured shear modulus most accurately represents the mechanical property of the muscle along the fascicle direction when the probe’s principal axis is parallel to the fascicle direction in the plane of the ultrasound image. However, it is unclear how the measured shear modulus is affected by the probe angle relative to the fascicle direction in the same plane. The purpose of the present study was therefore to examine whether the angle between the principal axis of the probe and the fascicle direction in the same plane affects the measured shear modulus. Shear modulus in seven specially-designed tissue-mimicking phantoms, and in eleven human in-vivo biceps brachii and medial gastrocnemius were determined by using ultrasound shear wave elastography. The probe was positioned parallel or 20° obliquely to the fascicle across the B-mode images. The reproducibility of shear modulus measurements was high for both parallel and oblique conditions. Although there was a significant effect of the probe angle relative to the fascicle on the shear modulus in human experiment, the magnitude was negligibly small. These findings indicate that the ultrasound shear wave elastography is a valid tool for evaluating the mechanical property of pennate muscles along the fascicle direction.  相似文献   

12.
The purpose of this study was to investigate the effect of the differences between the actual fascicle length during a voluntary contraction and the fascicle length at rest of the triceps surae muscle on the determination of the voluntary activation (VA) by using the interpolated twitch technique. Twelve participants performed isometric voluntary maximal (MVC) and submaximal (20%, 40%, 60% and 80% MVC) contractions at two different ankle angles (75 degrees and 90 degrees ) under application of the interpolated twitch technique. Two ultrasound probes were used to determine the fascicle length of soleus, gastrocnemius medialis and gastrocnemius lateralis muscles. Further, the MVCs and the twitches were repeated for six more ankle angles (85 degrees , 95 degrees , 100 degrees , 105 degrees , 110 degrees and 115 degrees ). The VA of the triceps surae muscle were calculated (a) using the rest twitch force (RTF) measured during the same trial as the interpolated twitch force (ITF; traditional method) and (b) using the RTF at an ankle angle where the fascicle length showed similar values between ITF and RTF (fascicle length consideration method). The continuous changes in fascicle length from rest to MVC affect the accuracy of the assessment of the VA. The traditional method overestimates the assessment of the VA on average 4% to 12%, especially at 90 degrees ankle angle (i.e. short muscle length). The reason for this influence is the unequal force-length potential of the muscle at twitch application by the measure of ITF and RTF. These findings provide evidence that the fascicle length consideration method permits a more precise prediction (an improvement of 4-12%) of the voluntary contraction compared to the traditional method.  相似文献   

13.
The purpose of this study was to compare the architectural parameters of the long head of biceps femoris (BFlh) and semitendinosus (ST) muscles by comparing measurements from ultrasound (US) with those obtained from direct dissection. The BFlh and ST architectures were examined bilaterally in 6 legs from 3 male cadavers. The fascicle length, pennation angle, muscle thickness and muscle and tendon length were obtained from direct measurement and US scans along each muscle. Intraclass correlation coefficients between the two methods ranged from 0.905 to 0.913 for the BFlh variables and from 0.774 to 0.974 for the ST parameters. Compared with the direct measurements, the US method showed a mean typical error of 0.09–0.14 cm for muscle thickness, 1.01–1.31° for the pennation angle, 0.92–1.71 cm for fascicle length and muscle–tendon length measurements. The US method is a valid alternative tool for assessing basic architectural parameters of ST and BFlh components of the hamstring muscles.  相似文献   

14.
The estimation of muscle fascicle behaviour is decisive in a Hill-type model as they are related to muscle force by the force–length–velocity relationship and the tendon force–strain relationship. This study was aimed at investigating the influence of subject-specific tendon force–strain relationship and initial fascicle geometry (IFG) on the estimation of muscle forces and fascicle behaviour during isometric contractions. Ultrasonography was used to estimate the in vivo muscle fascicle behaviour and compare the muscle fascicle length and pennation angle estimated from the Hill-type model. The calibration–prediction process of the electromyography-driven model was performed using generic or subject-specific tendon definition with or without IFG as constraint. The combination of subject-specific tendon definition and IFG led to muscle fascicle behaviour closer to ultrasound data and significant lower forces of the ankle dorsiflexor and plantarflexor muscles compared to the other conditions. Thus, subject-specific ultrasound measurements improve the accuracy of Hill-type models on muscle fascicle behaviour.  相似文献   

15.
Although muscle–tendon slack length is a crucial parameter used in muscle models, this is one of the most difficult measures to estimate in vivo. The aim of this study was to determine the onset of the rise in tension (i.e., slack length) during passive stretching in both Achilles tendon and gastrocnemius medialis. Muscle and tendon shear elastic modulus was measured by elastography (supersonic shear imaging) during passive plantarflexion (0° and 90° of knee angle, 0° representing knee fully extended, in a random order) in 9 participants. The within-session repeatability of the determined slack length was good at 90° of knee flexion (SEM=3.3° and 2.2° for Achilles tendon and gastrocnemius medialis, respectively) and very good at 0° of knee flexion (SEM=1.9° and 1.9° for Achilles tendon and gastrocnemius medialis, respectively). The slack length of gastrocnemius medialis was obtained at a significantly lower plantarflexed angle than for Achilles tendon at both 0° (P<0.0001; mean difference=19.4±3.8°) and 90° of knee flexion (P<0.0001; mean difference=25.5±7.6°). In conclusion, this study showed that the joint angle at which the tendon falls slack can be experimentally determined using supersonic shear imaging. The slack length of gastrocnemius medialis and Achilles tendon occurred at different joint angles. Although reporting this result is crucial to a better understanding of muscle–tendon interactions, further experimental investigations are required to explain this result.  相似文献   

16.
PurposeWe assessed fascicle behaviors of the upper extremities during isometric contractions at different joint angles in this study.MethodsThirteen healthy men and women performed isometric elbow extension tasks at 50% and 75% of maximal voluntary contraction (MVC) at 60°, 90°, and 120° of elbow extension (full extension = 180°). Extended field-of-view B-mode ultrasonography was used to obtain sagittal plane panoramic images of the long head (TB-Long) and medial head (TB-Med) of the triceps brachii at rest and during contraction; fascicle length and pennation angle were measured.ResultsIn the TB-Long, significant fascicle shortening from rest was found during 50% and 75%MVC at 60° and during 75%MVC at 90° of extension. There was no significant fascicle shortening in the TB-Med muscle under any conditions. There was no significant pennation angle change from rest in either muscle. The pennation angle of the TB-Long was significantly greater than that of the TB-Med under all conditions.ConclusionsThese results suggest that fascicle shortening in the TB-Long muscle occurs in flexion; however, no change was found in the TB-Med. In the upper extremity muscle–tendon complex, the superficial and deeper muscles may have different force-transmission efficiency at flexed joint angles.  相似文献   

17.
Fukunaga, Tetsuo, Yoshiho Ichinose, Masamitsu Ito, YasuoKawakami, and Senshi Fukashiro. Determination of fascicle lengthand pennation in a contracting human muscle in vivo.J. Appl. Physiol. 82(1): 354-358, 1997.We have developed a technique to determine fascicle length inhuman vastus lateralis muscle in vivo by using ultrasonography. Whenthe subjects had the knee fully extended passively from a position of110° flexion (relaxed condition), the fascicle length decreasedfrom 133 to 97 mm on average. During static contractions at 10% ofmaximal voluntary contraction strength (tensed condition), fascicleshortening was more pronounced (from 126 to 67 mm), especially when theknee was closer to full extension. Similarly, as the knee was extended, the angle of pennation (fascicle angle, defined as the angle between fascicles and aponeurosis) increased (relaxed, from 14 to 18°; tensed, from 14 to 21°), and a greater increase in the pennation angle was observed in the tensed than in the relaxed condition when theknee was close to extension (<40°). We conclude that there aredifferences in fascicle lengths and pennation angles when the muscle isin a relaxed and isometrically tensed conditions and that thedifferences are affected by joint angles, at least at thesubmaximal contraction level.

  相似文献   

18.
While muscle contraction in voluntary efforts has been widely investigated, little is known about contraction during neuromuscular electrical stimulation (NMES). The aim of this study was to quantify in vivo muscle architecture of agonist and antagonist muscles at the ankle joint during NMES. Muscle fascicle lengths and pennation angles of the tibialis anterior (TA) and lateral gastrocnemius muscles were assessed via ultrasonography in 8 healthy young males. Measures were obtained during maximal NMES and torque-matched voluntary dorsiflexion contractions. In the TA, NMES induced a shorter fascicle length (67.2 ± 8.1 mm vs 74.6 ± 11.4 mm; p = 0.04) and a greater pennation angle (11.0 ± 2.4° vs 9.3 ± 2.5°; p = 0.03) compared with voluntary torque-matched dorsiflexion contractions. Architectural responses in the antagonist lateral gastrocnemius muscle did not significantly differ from rest or between voluntary and electrically induced contractions (p > 0.05). Contraction of the antagonist muscle was not a contributing factor to a greater fascicle shortening and increased pennation angle in the TA during NMES. TA architectural response during NMES likely arose from the contribution of muscle synergists during voluntary contractions coupled with a potentially localized contractile activity under the stimulation electrodes during NMES induced contractions.  相似文献   

19.
The aim of this study is to present a detailed continuum mechanics formulation, and the corresponding algorithms, to predict the deformation of skeletal muscle at different structural levels, starting from the muscle fiber level. The model is used to investigate force production and structural changes during isometric and dynamic contractions of the cat medial gastrocnemius. From a comparison with experimental data obtained in our own laboratories, we conclude that the model faithfully predicts all of the observations pertaining to force production, fascicle length and angle of pennation under various test conditions.  相似文献   

20.
For detailed analyses of muscle adaptation mechanisms during growth, ageing or disease, reliable measurements of muscle architecture are required. Diffusion tensor imaging (DTI) and DTI tractography have been used to reconstruct the architecture of human muscles in vivo. However, muscle architecture measurements reconstructed with conventional DTI techniques are often anatomically implausible because the reconstructed fascicles do not terminate on aponeuroses, as real muscle fascicles are known to do. In this study, we tested the reliability of an anatomically constrained DTI-based method for measuring three-dimensional muscle architecture. Anatomical magnetic resonance images and diffusion tensor images were obtained from the left legs of eight healthy participants on two occasions one week apart. Muscle volumes, fascicle lengths, pennation angles and fascicle curvatures were measured in the medial and lateral gastrocnemius, soleus and the tibialis anterior muscles. Averaged across muscles, the intraclass correlation coefficient was 0.99 for muscle volume, 0.81 for fascicle length, 0.73 for pennation angle and 0.76 for fascicle curvature. Measurements of muscle architecture obtained using conventional DTI tractography were highly sensitive to variations in the stopping criteria for DTI tractography. The application of anatomical constraints reduced this sensitivity significantly. This study demonstrates that anatomically constrained DTI tractography can provide reliable and robust three-dimensional measurements of whole-muscle architecture. The algorithms used to constrain tractography have been made publicly available.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号