首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
BackgroundMedicine quality screening devices hold great promise for post-market surveillance (PMS). However, there is little independent evidence on their field utility and usability to inform policy decisions. This pilot study in the Lao PDR tested six devices’ utility and usability in detecting substandard and falsified (SF) medicines.Methodology/principal findingsObservational time and motion studies of the inspections by 16 Lao medicine inspectors of 1) the stock of an Evaluation Pharmacy (EP), constructed to resemble a Lao pharmacy, and 2) a sample set of medicines (SSM); were conducted without and with six devices: four handheld spectrometers (two near infrared: MicroPHAZIR RX, NIR-S-G1 & two Raman: Progeny, Truscan RM); one portable mid-infrared spectrometer (4500a), and single-use paper analytical devices (PAD). User experiences were documented by interviews and focus group discussions.Significantly more samples were wrongly categorised as pass/fail with the PAD compared to the other devices in EP inspections (p<0.05). The numbers of samples wrongly classified in EP inspections were significantly lower than in initial visual inspections without devices for 3/6 devices (NIR-S-G1, MicroPHAZIR RX, 4500a). The NIR-S-G1 had the fastest testing time per sample (median 93.5 sec, p<0.001). The time spent on EP visual inspection was significantly shorter when using a device than for inspections without devices, except with the 4500a, risking missing visual clues of samples being SF. The main user errors were the selection of wrong spectrometer reference libraries and wrong user interpretation of PAD results. Limitations included repeated inspections of the EP by the same inspectors with different devices and the small sample size of SF medicines.Conclusions/significanceThis pilot study suggests policy makers wishing to implement portable screening devices in PMS should be aware that overconfidence in devices may cause harm by reducing inspectors’ investment in visual inspection. It also provides insight into the advantages/limitations of diverse screening devices in the hands of end-users.  相似文献   

2.
Substandard and falsified (SF) antimalarials have devastating consequences including increased morbidity, mortality and economic losses. Portable medicine quality screening devices are increasingly available, but whether their use for the detection of SF antimalarials is cost-effective is not known. We evaluated the cost-effectiveness of introducing such devices in post-market surveillance in pharmacies in Laos, conservatively focusing on their outcome in detecting SF artemisinin-based combination therapies (ACTs). We simulated the deployment of six portable screening devices: two handheld near-infrared [MicroPHAZIR RX, NIR-S-G1], two handheld Raman [Progeny, TruScan RM]; one portable mid-infrared [4500a FTIR] spectrometers, and single-use disposable paper analytical devices [PADs]. We considered two scenarios with high and low levels of SF ACTs. Different sampling strategies in which medicine inspectors would test 1, 2, or 3 sample(s) of each brand of ACT were evaluated. Costs of inspection including device procurement, inspector time, reagents, reference testing, and replacement with genuine ACTs were estimated. Outcomes were measured as disability adjusted life years (DALYs) and incremental cost-effectiveness ratios were estimated for each device compared with a baseline of visual inspections alone. In the scenario with high levels of SF ACTs, all devices were cost-effective with a 1-sample strategy. In the scenario of low levels of SF ACTs, only four devices (MicroPHAZIR RX, 4500a FTIR, NIR-S-G1, and PADs) were cost-effective with a 1-sample strategy. In the multi-way comparative analysis, in both scenarios the NIR-S-G1 testing 2 samples was the most cost-effective option. Routine inspection of ACT quality using portable screening devices is likely to be cost-effective in the Laos context. This work should encourage policy-makers or regulators to further investigate investment in portable screening devices to detect SF medicines and reduce their associated undesired health and economic burdens.  相似文献   

3.
BackgroundArtemisinin-based combination therapies are recommended by the World Health Organisation (WHO) as first-line treatment for Plasmodium falciparum malaria, yet medication must be of good quality for efficacious treatment. A recent meta-analysis reported 35% (796/2,296) of antimalarial drug samples from 21 Sub-Saharan African countries, purchased from outlets predominantly using convenience sampling, failed chemical content analysis. We used three sampling strategies to purchase artemisinin-containing antimalarials (ACAs) in Enugu metropolis, Nigeria, and compared the resulting quality estimates.MethodsACAs were purchased using three sampling approaches - convenience, mystery clients and overt, within a defined area and sampling frame in Enugu metropolis. The active pharmaceutical ingredients were assessed using high-performance liquid chromatography and confirmed by mass spectrometry at three independent laboratories. Results were expressed as percentage of APIs stated on the packaging and used to categorise each sample as acceptable quality, substandard, degraded, or falsified.ResultsContent analysis of 3024 samples purchased from 421 outlets using convenience (n=200), mystery (n=1,919) and overt (n=905) approaches, showed overall 90.8% ACAs to be of acceptable quality, 6.8% substandard, 1.3% degraded and 1.2% falsified. Convenience sampling yielded a significantly higher prevalence of poor quality ACAs, but was not evident by the mystery and overt sampling strategies both of which yielded results that were comparable between each other. Artesunate (n=135; 4 falsified) and dihydroartemisinin (n=14) monotherapy tablets, not recommended by WHO, were also identified.ConclusionRandomised sampling identified fewer falsified ACAs than previously reported by convenience approaches. Our findings emphasise the need for specific consideration to be given to sampling frame and sampling approach if representative information on drug quality is to be obtained.  相似文献   

4.

Background

Poor-quality life-saving medicines are a major public health threat, particularly in settings with a weak regulatory environment. Insufficient amounts of active pharmaceutical ingredients (API) endanger patient safety and may contribute to the development of drug resistance. In the case of malaria, concerns relate to implications for the efficacy of artemisinin-based combination therapies (ACT). In Papua New Guinea (PNG), Plasmodium falciparum and P. vivax are both endemic and health facilities are the main source of treatment. ACT has been introduced as first-line treatment but other drugs, such as primaquine for the treatment of P. vivax hypnozoites, are widely available. This study investigated the quality of antimalarial drugs and selected antibiotics at all levels of the health facility supply chain in PNG.

Methods and Findings

Medicines were obtained from randomly sampled health facilities and selected warehouses and hospitals across PNG and analysed for API content using validated high performance liquid chromatography (HPLC). Of 360 tablet/capsule samples from 60 providers, 9.7% (95% CI 6.9, 13.3) contained less, and 0.6% more, API than pharmacopoeial reference ranges, including 29/37 (78.4%) primaquine, 3/70 (4.3%) amodiaquine, and one sample each of quinine, artemether, sulphadoxine-pyrimethamine and amoxicillin. According to the package label, 86.5% of poor-quality samples originated from India. Poor-quality medicines were found in 48.3% of providers at all levels of the supply chain. Drug quality was unrelated to storage conditions.

Conclusions

This study documents the presence of poor-quality medicines, particularly primaquine, throughout PNG. Primaquine is the only available transmission-blocking antimalarial, likely to become important to prevent the spread of artemisinin-resistant P. falciparum and eliminating P. vivax hypnozoites. The availability of poor-quality medicines reflects the lack of adequate quality control and regulatory mechanisms. Measures to stop the availability of poor-quality medicines should include limiting procurement to WHO prequalified products and implementing routine quality testing.  相似文献   

5.
BackgroundWe aimed to evaluate the utility of the combined use of cardiac 123I-metaiodobenzylguanidine (MIBG) scintigraphy, olfactory testing, and substantia nigra (SN) hyperechogenicity on transcranial sonography (TCS) in differentiating Parkinson’s disease (PD) from atypical parkinsonian syndromes (APSs), such as multiple system atrophy (MSA) and progressive supranuclear palsy (PSP).MethodsCardiac MIBG scintigraphy, card-type odor identification testing (Open Essence (OE), Wako, Japan), and TCS were performed with 101 patients with PD and 38 patients with APSs (MSA and PSP). Receiver operating characteristic (ROC) curve analysis was used to assess the sensitivity and specificity of these batteries for diagnosing PD from APSs. The diagnostic accuracy of the three tests was also assessed among patients at the early disease stage (drug-naïve patients with a disease duration of 3 years or less).ResultsIn differentiating PD from APSs, the area under the ROC curve was 0.74 (95% CI, 0.65–0.83), 0.8 (95% CI, 0.73–0.87), and 0.75 (95% CI, 0.67–0.82) for TCS, cardiac MIBG scintigraphy, and olfactory testing, respectively. The diagnostic sensitivity and specificity were 53.1% and 91.7%, respectively, for TCS, 70.3% and 86.8%, respectively, for cardiac MIBG scintigraphy, 58.4% and 76.3%, respectively, for OE. Among early-stage patients, sensitivity and specificity were 50.0% and 93.8%, respectively, for TCS, 57.1% and 87.5%, respectively, for cardiac MIBG scintigraphy, and 54.8% and 79.2%, respectively, for OE. At least one positive result from 3 tests improved sensitivity (86.1%) but decreased specificity (63.2%). In contrast, at least 2 positive results from 3 tests had good discrimination for both early-stage patients (50.0% sensitivity and 93.8% specificity) and patients overall (57.8% sensitivity and 95.8% specificity). Positive results for all 3 tests yielded 100% specificity but low sensitivity (25%).ConclusionsAt least 2 positive results from among TCS, cardiac MIBG scintigraphy, and olfactory testing can support clinical diagnosis in distinguishing PD from APSs.  相似文献   

6.
BackgroundEven though the international combat against Neglected Tropical Diseases such as schistosomiasis or soil-transmitted helminthiases depends on reliable therapeutics, anthelminthic pharmacovigilance has been neglected on many national African drug markets. Therefore, quality and composition of Albendazole, Mebendazole and Praziquantel locally collected in Burkina Faso, Côte d’Ivoire, Ghana and Tanzania were analysed.MethodsSamples of 88 different batches were obtained from randomly selected facilities. Sampling took place in Northwest Tanzania, Western Burkina Faso, Southeast Côte d’Ivoire and Southwest Ghana. Visual examination of both packaging and samples was performed according to the WHO ‘Be Aware’ tool. Products were then screened with the GPHF Minilab, consisting of tests of mass uniformity, disintegration times and thin-layer chromatography (TLC). Confirmatory tests were performed according to international pharmacopoeiae, applying assays for dissolution profiles and high-performance liquid chromatography (HPLC).FindingsDespite minor irregularities, appearance of the products did not hint at falsified medicines. However, 19.6% of the brands collected in Ghana and Tanzania were not officially licensed for sale. Mass uniformity was confirmed in 53 out of 58 brands of tablets. 41 out of 56 products passed disintegration times; 10 out of the 15 failing products did not disintegrate at all. Evaluating TLC results, only 4 out of 83 batches narrowly missed specification limits, 18 batches slightly exceeded them. Not more than 46.3% (31 / 67) of the tablets assayed passed the respective pharmaceutical criteria for dissolution. HPLC findings confirmed TLC results despite shifted specification limits: 10 out of 83 tested batches contained less than 90%, none exceeded 110%.ConclusionIn the four study countries, no falsified anthelminthic medicine was encountered. The active pharmaceutical ingredient was not found to either exceed or fall below specification limits. Galenic characteristics however, especially dissolution profiles, revealed great deficits.  相似文献   

7.
A prospective study was undertaken to compare flow cytometric (FCM) analysis to conventional cytologic evaluation for the detection of malignant cells in peritoneal fluids (peritoneal lavages and ascitic fluids) from women with gynecologic diseases. The 94 peritoneal fluids analyzed came from 63 cancer patients (with epithelial ovarian carcinomas) and 31 control patients (with benign gynecologic diseases). The FCM DNA histograms were generated using propidium iodide as a DNA fluorochrome. Samples for cytologic analysis were stained with the standard May-Grünwald-Giemsa or Papanicolaou stains. Of the 94 samples, 90 were evaluable cytologically while 70 were suitable for FCM analysis. The sensitivities were 55% for FCM DNA analysis and 80% for cytologic analysis. FCM DNA analysis had a 30% false-positive rate; cytologic analysis produced no false-positive results. These results indicate that there is no advantage in employing FCM analysis instead of conventional cytologic evaluation for the detection of malignant cells in peritoneal fluids from gynecologic cases.  相似文献   

8.
ObjectivesResults of studies on the prevalence of distal diabetic polyneuropathy (DPN) are contradictory. Conventional methods used for the diagnosis of DPN in clinical practice have limited effectiveness. The present study aimed to assess the prevalence of DPN in a population with long-standing diabetes (more than 10 years disease duration) by measuring vibratory, thermal and tactile sensitivities with quantitative sensory devices, as well as their relationship with associated clinical risk factors.Patients and methodsA total of 1011 diabetic patients were evaluated in a multicenter, cross-sectional, observational study. The three sensitivities were assessed by ultrabiothesiometer, aesthesiometer and thermoskin devices, respectively. The prevalence of neuropathic pain was validated by the DN4 questionnaire.ResultsOf the 1011 cases included, 400 (39.6%) met the diagnostic criteria of DPN, while no DPN was found in the remaining 611 (60.4%). Of the 400 patients with DPN, 253 (63.2%) showed clinical manifestations, while 147 (36.8%) were diagnosed as subclinical DPN. The prevalence of DPN increased with disease duration. There was a progressive loss of the three sensitivities with increased disease duration, particularly thermal and vibratory sensitivities. This loss was statistically significant for the latter two sensitivities. Among patients with clinical DPN, 84.2% had painful neuropathic symptoms. The prevalence of DPN was positively related to micro- and macroangiopathic complications and with dyslipidemia.ConclusionThis study reveals a high degree of underdiagnosis of DPN, most likely due to the asymptomatic nature of the disease in a considerable proportion of patients. Our observations provide evidence of the usefulness of specific equipment for quantitative and objective assessment of polyneuropathy.  相似文献   

9.
目的:通过激光共聚焦显微镜对肿瘤生物治疗后患者的外周血淋巴细胞进行亚群计数,为生物治疗后外周血淋巴细胞无法分群的肿瘤患者提供新的监测免疫功能状态的方法。方法:收集35例肿瘤生物治疗后患者的外周血标本,通过激光共聚焦显微镜和流式细胞仪两种方法分别对患者外周血淋巴细胞亚群进行分类计数。结果:流式细胞仪和激光共聚焦显微镜同时分类计数的患者外周血细胞标本30例,两种方法在检测CD3、CD3~+/CD4~+、CD3~+/CD8~+、CD3-/CD16~+56~+、CD3-/CD19~+细胞时均无统计学差异(P值0.05);5例流式细胞仪无法将患者外周血淋巴细胞分群的样本,通过激光共聚焦显微镜可以进行分类计数。结论:激光共聚焦显微镜亦可以用于外周血淋巴细胞的分类计数。  相似文献   

10.
Drug safety has become a very important subject, and more countries have joined in the fight against counterfeit drugs. This study demonstrated a non-invasive Raman spectroscopy method that could be utilized for screening liquid injectable drugs for spurious/falsely-labeled/falsified/counterfeit medical products (SFFCs). Two problems were solved to remove the blocks in identification and quantitation: one problem was the weak API signal extraction from the non-invasive Raman spectra and the other was the problem of Raman absolute measurement. Principal component analysis (PCA) and classical least square (CLS) algorithms were performed to establish the models. Water was chosen as the “internal standard” to normalize the spectra to solve the problem of Raman absolute measurement. The results showed that the 11 positive samples and 66 negative samples were all well identified with a threshold of 0.95. One of the positive samples contained the excipient propylene glycol, which was identified successfully at the same time. The accuracy of quantitative results was approximately 5% for doxofylline liquid injectables and about 10% for the low-concentration and big glass bottle-containers of Levofloxacin Lactate and Sodium Chloride Injections as compared to the results using an HPLC method, this is satisfactory for fast screening of SFFCs. In conclusion, with the development of a database of identification and quantitation models, this method may determine liquid injectable drugs in a fast and non-invasive way and become one of the most powerful weapons against SFFCs.

Graphical Abstract

Open in a separate window

Electronic supplementary material

The online version of this article (doi:10.1208/s12249-015-0286-0) contains supplementary material, which is available to authorized users.KEY WORDS: CLS, liquid injectables, non-invasive Raman fast screening method, PCA, SFFCs (Spurious/falsely-labeled/falsified/counterfeit medical products)  相似文献   

11.
Twenty-five yeast strains isolated from sourdough samples for Panettone, Pandoro and Cornetto brioche manufactured by eight different bakeries in northern Italy were characterised. Classification was performed by the simplified identification method (SIM), Kurtzman and Fell's identification protocol, the API system from bioMérieux (France) and the MicroLog system from Biolog (USA). Genetic diversity was investigated by randomly amplified polymorphic DNA fingerprinting and mitochondrial-DNA restriction enzyme analysis. Sequences of the internal transcribed spacers between 18S and 26S rDNA genes were analysed. Candida humilis was the predominant species (56% of isolates), whereas the remaining strains (44%) were related to the Saccharomyces cerevisiae sensu stricto group. Identification systems based on phenotypic analysis proved to be unreliable to identify yeasts from sourdough. Either RAPD-PCR or mtDNA restriction analysis showed to be suitable for the identification of species, but could not be used to differentiate among the isolates at the strain level. Sequencing of the ITS region permitted a consistent classification of the sourdough yeasts.  相似文献   

12.
Telcagepant (MK-0974) is a novel oral calcitonin gene-related peptide (CGRP) receptor antagonist and is currently under clinical development. Results from phases II and III clinical trials have suggested that telcagepant is effective for migraine treatment. A reliable and high throughput protein precipitation (PPT) method for determination of telcagepant in human plasma using liquid chromatography coupled with atmospheric pressure chemical ionization (APCI) tandem mass spectrometry has been developed. Clinical samples, internal standard (IS) and acetonitrile are transferred into 96-well plates using a robotic liquid handling system. An aliquot of 10 μL supernatant is directly injected into the LC–MS/MS system where separation is performed on a FluoPhase RP (150 × 2.1 mm, 5 μm) column with an isocratic mobile phase (60% acetonitrile with 0.1% formic acid and 40% water with 0.1% formic acid) at 0.2 mL/min. The interfering 3S-diastereomer of telcagepant, which is observed in clinical samples, is chromatographically resolved from telcagepant. The PPT procedure significantly reduces the time required for sample processing and the assay is sufficiently sensitive for detection using both API 4000 and API 3000 mass spectrometers. The linear calibration range is 5–5000 nM using 200 μL of plasma. Assay intraday validation was conducted using six calibration curves derived from six lots of human control plasma. Calibration standard accuracy did not deviate by more than 3% and 6% of nominal values, and precision did not exceed 4% coefficient of variation (CV) and 10% CV, respectively on the API 4000 and API 3000. Several clinical phases IIb and III studies have been successfully supported with this assay.  相似文献   

13.
BackgroundThe association between socioeconomic position and incidence of colorectal cancer is inconsistent and differs by global region. We aimed to clarify this association in the Swedish population.MethodsWe conducted a population-based open cohort study using data from Swedish national registers. We included all individuals, aged ≥30 years, residing in Sweden between 1993 and 2010. Socioeconomic position was indicated by (1) highest educational level (five groups), and (2) disposable income (quintiles). We used Poisson regression to estimate incidence rate ratios (IRR) and 95% confidence intervals (95% CI) of colon and rectal cancer, and colon and rectal dysplasia.ResultsIn total, 97,827,817 person-years were accumulated and 82,686 cases of colorectal cancer were diagnosed. Compared to men with ‘higher secondary’ education, the adjusted IRRs (95% CI) of rectal cancer in men with ‘primary or less’, ‘lower secondary’, ‘lower university’ or ‘higher university’ education were: 1.06 (1.00, 1.11), 1.05 (0.99, 1.10), 0.96 (0.89, 1.03), and 0.92 (0.86, 0.98), respectively. In women, the corresponding figures were: 1.04 (0.95, 1.14), 1.03 (0.94, 1.13), 0.92 (0.82, 1.02) and 0.92 (0.82, 1.02). Disposable income was not associated with rectal cancer incidence. Adjusted IRRs of colon cancer did not differ between levels of education or disposable income overall or for specific colon sub-sites. Neither education nor disposable income was consistently associated with incidence of colon or rectal dysplasia.ConclusionsPrevention strategies for colon cancer should be applicable to individuals regardless of their socioeconomic position. However, factors conferred by education, e.g., health awareness, may be important for approaches aiming to reduce inequalities in incidence of rectal cancer. Further evaluation of cancer prevention and health promotion strategies among less educated groups is warranted.  相似文献   

14.
Nanowires (NWs) are critically important building blocks of nanotechnology for sensing, biosensing and bioelectronics. However, in order to avoid complex and stiff configurations reported, a simpler and disposable approach is needed. Nickel nanowires (NiNWs) are one of the most promising alternatives because they allow magnetic manipulations through the application of an external magnetic field and they remain to be exploited in analytical field for electrochemical biosensing in real samples. In this work, NiNWs were characterized by scanning electronic microscopy (SEM), transmission electronic microscopy (TEM), energy-dispersive X-ray spectrometry (EDS) and X-ray photoelectronic spectroscopy (XPS) and then easily used in the construction of disposable detectors on carbon-screen printed electrodes (CSPEs). Fabricated NiNWs using alumina templates were about 330 nm of diameter and 6 μm lengths. XPS revealed that NiNWs based electrodes contained just a 0.9% of Ni with an enhancement of current density of about 65 times in comparison with Ni-bulk electrode under flow conditions. Electrochemically activated NiNWs (at -1.5 V, 600 s under magnetic field of 2×4200 G) gave the best signal-to-noise performance exhibiting fast response time to representative carbohydrate, very good mechanical stability, no memory effect and an extreme resistance to fouling under hydrodynamics conditions allowing an excellent analytical performance on the board of just one disposable single-electrode (RSDs≤7%, n=50). Analytical performance of NiNWs was also excellent in the analysis of selected samples exhibiting very good reliability, precision (RSDs≤2%) and recovery rates (95-115%). NiNWs are becoming a simple and easy-to-use nanotool for fast, reliable and decentralized sensing of carbohydrates; and as a consequence, "disposable nanoanalytics" is approaching.  相似文献   

15.
BackgroundLeptospirosis is considered an endemic disease among agricultural workers in Okinawa Prefecture, which is the southernmost part of Japan and has a subtropical climate, but data on the current status and trend of this disease are scarce.Methodology/principal findingsWe conducted a retrospective study of clinically suspected leptospirosis patients whose sample and information were sent to the Okinawa Prefectural Institute of Health and Environment from November 2003 to December 2020. Laboratory diagnosis was established using culture, nested polymerase chain reaction (PCR), and/or microscopic agglutination test (MAT) with blood, cerebrospinal fluid, and/or urine samples. Statistical analyses were performed to compare the epidemiological information, clinical features, and sensitivities of diagnostic methods among laboratory-confirmed cases. Serogroups and the species of Leptospira isolates were determined by MAT using 13 antisera and flaB sequencing.A total of 531 clinically suspected patients were recruited, among whom 246 (46.3%) were laboratory confirmed to have leptospirosis. Among the confirmed cases, patients aged 20–29 years (22.4%) and male patients (85.7%) were the most common. The most common estimated sources of infection were recreation (44.5%) and labor (27.8%) in rivers. Approximately half of the isolates were of the L. interrogans serogroup Hebdomadis. The main clinical symptoms were fever (97.1%), myalgia (56.3%), and conjunctival hyperemia (52.2%). Headache occurred significantly more often in patients with Hebdomadis serogroup infections than those with other serogroup infections. The sensitivities of culture and PCR exceeded 65% during the first 6 days, while the sensitivity of MAT surpassed that of culture and PCR in the second week after onset. PCR using blood samples was a preferable method for the early diagnosis of leptospirosis.Conclusions/significanceThe results of this study will support clinicians in the diagnosis and treatment of undifferentiated febrile patients in Okinawa Prefecture as well as patients returning from Okinawa Prefecture.  相似文献   

16.
Flow cytometric analysis and cytopathology of body cavity fluids   总被引:4,自引:0,他引:4  
A total of 75 samples of body cavity fluids from 71 patients were analyzed by both flow cytometry (FCM), to detect cells with an abnormal DNA content (aneuploidy), and by conventional cytopathology. Samples included 27 pleural fluids, 35 peritoneal fluids, 11 peritoneal washings and 2 pericardial fluids. For cytologic examination, the samples were prepared using standard techniques. Samples for FCM analysis were centrifuged and exposed to a hypotonic solution containing detergent and propidium iodide, a DNA intercalating fluorescent stain. Aneuploidy as well as cytologic malignancy were found in 17 samples. Forty-seven samples had normal DNA histograms by FCM and were also cytologically negative. Four samples suspicious by cytology but normal by FCM were from patients with renal-cell carcinoma (two samples from the same patient), endometrial adenocarcinoma without metastasis and chronic lymphocytic leukemia. Three samples abnormal by FCM but negative by cytology were from patients with ovarian cystadenoma, cirrhosis and uterine leiomyoma. FCM showed aneuploidy in four cytologically negative samples from patients with histologically proven malignancy (lymphoma, colonic adenocarcinoma, cervical squamous cell carcinoma, and endometrial adenosquamous carcinoma). Based on these results, FCM analysis combined with conventional cytopathology yielded 100% sensitivity, 100% predictive value of a negative result and 94% specificity. This rapid and quantitative FCM analysis of body cavity fluids can be a very useful adjunct to conventional diagnostic cytopathology.  相似文献   

17.
《Process Biochemistry》2010,45(7):1082-1087
In the present research, the potential use of flexible disposable devices, specifically blood bags, for the fractionation of biological products using Aqueous Two-Phase Systems (ATPS) polymer–salt is studied and demonstrated. Purified human serum albumin (HSA) was used as model protein. Experiments were carried out on ATPS polyethylene glycol (PEG)–potassium phosphate constructed on rigid recipients (conical tubes) and flexible devices (blood bags). The device used for ATPS construction had no significant effect on HSA partition behavior. Protein partition towards the top phase was favored on systems constructed using PEG 1000 g/mol and TLL 45% (w/w), achieving up to 85% recovery. On the other hand a recovery of 92% was achieved at the bottom phase when PEG 3350 g/mol and TLL 25% (w/w) were used. Human serum was used as a complex sample on ATPS experiments. Selective fractionation of human serum proteins on ATPS constructed on flexible devices was achieved. ATPS constructed on blood bags required short equilibrium times (< 6 min), meaning it is feasible to use this approach on mass scale. The potential use of flexible disposable devices, for the fractionation of biological products using ATPS polymer–salt was demonstrated.  相似文献   

18.
More than 50% of spontaneous abortions (SAs) have abnormal chromosomes; the most common abnormalities are trisomy, sex chromosome monosomy, and polyploidy. Conventional cytogenetic analysis of SAs depends on tissue culturing and is associated with a significant tissue culture failure rate and contamination by maternally derived cells. Comparative genomic hybridization (CGH), in combination with flow cytometry (FCM), can detect numerical and unbalanced structural chromosomal abnormalities associated with SAs while avoiding the technical problems associated with tissue culture. Routine cytogenetic and CGH analysis was performed independently on tissue from 301 SAs. Samples shown to be chromosomally balanced by CGH were analyzed by FCM to determine ploidy. Of 253 samples successfully analyzed by both approaches, there was an absolute correlation of results in 235 (92.8%). Of the 18 cases with discrepancies between cytogenetic and CGH/FCM results, an explanation could be found in 17. Twelve samples produced a 46,XX karyotype by cytogenetics, whereas CGH/FCM demonstrated aneuploidy/polyploidy or a male genome, indicating maternal contamination of the tissue cultures. In two cases, where tetraploidy was demonstrated by cytogenetics and diploidy by FCM, tissue culture artifact is implied. In three cases, CGH demonstrated an aneuploidy, and cytogenetics demonstrated hypertriploidy. In one unexplainable case, aneuploidy demonstrated by CGH could not be detected by repeat CGH analysis, conventional cytogenetic, or FISH analysis. These results demonstrate that CGH supplemented with FCM can readily identify chromosomal abnormalities associated with SAs and, by avoiding maternal contamination and tissue culture artifacts, can do so with a lower failure rate and more accuracy than conventional cytogenetic analysis.  相似文献   

19.
OBJECTIVE: To evaluate discrepancies between flow cytometry (FCM) and image cytometry (ICM), ploidy incidence and relation between DNA ploidies and survival in distal bile duct carcinomas (DBDCs). STUDY DESIGN: Forty-four archival tumor samples from patients with DBDC who underwent subtotal pancreatoduodenectomy from 1985 to 1996 were examined for DNA ploidy using FCM and ICM. RESULTS: Overall, 59% (26/44) of the tumors were aneuploid by at least one of the two techniques. We detected more cases of aneuploidy with ICM than FCM in formalin-fixed, paraffin-embedded DBDCs, 62% (21/34) versus 33% (13/40), respectively. When results could be compared, moderate strength of agreement (kappa = .45) was demonstrated. No correlation was found between DNA ploidy by FCM, ICM or combined FCM-ICM and survival time (P = .80, P = .35, and P = .54, respectively). CONCLUSION: Approximately 59% of DNA histograms contained aneuploid cell populations. Although ICM, as compared to FCM, is more sensitive in assessing the ploidy status of DBDC, both methods were complementary. Most discrepancies between FCM and ICM were due to the dilution of aneuploid populations by non-neoplastic diploid cells. DNA ploidy assessment in DBDC did not offer the possibility of improving the ability to predict survival.  相似文献   

20.
BackgroundAdherence to medicines is low for a variety of reasons, including the cost borne by patients. Some jurisdictions publicly fund medicines for the general population, but many jurisdictions do not, and such policies are contentious. To our knowledge, no trials studying free access to a wide range of medicines have been conducted.Methods and findingsWe randomly assigned 786 primary care patients who reported not taking medicines due to cost between June 1, 2016 and April 28, 2017 to either free distribution of essential medicines (n = 395) or to usual medicine access (n = 391). The trial was conducted in Ontario, Canada, where hospital care and physician services are publicly funded for the general population but medicines are not. The trial population was mostly female (56%), younger than 65 years (83%), white (66%), and had a low income from wages as the primary source (56%). The primary outcome was medicine adherence after 2 years. Secondary outcomes included control of diabetes, blood pressure, and low-density lipoprotein (LDL) cholesterol in patients taking relevant treatments and healthcare costs over 2 years. Adherence to all appropriate prescribed medicines was 38.7% in the free distribution group and 28.6% in the usual access group after 2 years (absolute difference 10.1%; 95% confidence interval (CI) 3.3 to 16.9, p = 0.004). There were no statistically significant differences in control of diabetes (hemoglobin A1c 0.27; 95% CI −0.25 to 0.79, p = 0.302), systolic blood pressure (−3.9; 95% CI −9.9 to 2.2, p = 0.210), or LDL cholesterol (0.26; 95% CI −0.08 to 0.60, p = 0.130) based on available data. Total healthcare costs over 2 years were lower with free distribution (difference in median CAN$1,117; 95% CI CAN$445 to CAN$1,778, p = 0.006). In the free distribution group, 51 participants experienced a serious adverse event, while 68 participants in the usual access group experienced a serious adverse event (p = 0.091). Participants were not blinded, and some outcomes depended on participant reports.ConclusionsIn this study, we observed that free distribution of essential medicines to patients with cost-related nonadherence substantially increased adherence, did not affect surrogate health outcomes, and reduced total healthcare costs over 2 years.Trial registrationClinicalTrials.gov NCT02744963.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号