首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A method for the separation of folinic acid diastereomers by capillary electrophoresis in chiral separation media was developed. Aiming to achieve a good separation of the anionic analytes, a newly synthesized cationic β-cyclodextrin derivative, mono-6-deoxy-6-piperdine-β-cyclodextrin, was applied as the chiral selector. The effect of background electrolyte pH, the concentration of the cyclodextrin additive, and organic modifier on the separation was investigated. A good separation of folinic acid diastereomers was obtained with 30 mmol/L phosphate buffer at pH 6.50 containing 6.0 mmol/L of mono-6-deoxy-6-piperdine-β-cyclodextrin in 10% acetonitrile. Based on the capillary electrophoresis data, the binding constants of each diastereomer with mono-6-deoxy-6-piperdine-β-cyclodextrin were determined. Moreover, a computational modeling study, using the semi-empirical PM3 method, was used to discuss the possible mechanism of separation of folinic acid with mono-6-deoxy-6-piperdine-β-cyclodextrin.  相似文献   

2.
The separation of compounds possessing amino groups (peptides, proteins, polyamino compounds) by capillary zone electrophoresis suffers from the interaction (sticking) of these solutes with the capillary wall. This sticking can result in the absence or incomplete separation of compounds or even in their retention in the capillary. Polyamidoamine (PAMAM) dendrimers are a class of spherical polymers with primary amino groups at the surface. These compounds can be separated reasonably well at acidic pH but not at neutral pH. A new method based on the dynamic coating of the capillary was developed for the separation of these compounds at pH 7.4. The method comprises separation in a fused-silica capillary (57 cm total length, 50 cm to the detector, ID 75 microm) and a background electrolyte consisting of a Tris-phosphate buffer (50 mmol/L, pH 7.4) and 0.05% (w/v) polyethyleneimine. This system is suitable for the separation of 7 generations of dendrimers (generations 0-6). The dynamic coating agent (polyethyleneimine) also improves the separation at acid pH.  相似文献   

3.
The article deals with the optimization of conditions for the chemiluminescence determination. The Daphnia habitat was shown to have no spontaneous chemiluminescence. This was revealed using hydrogen peroxide and luminol, the optimal concentrations of which were 23 and 1.6 x 10(-2) mmol/L. p-Iodphenol at low concentrations (4 x 10(-5)-2 x 10(-3) mmol/L) did not render its effect chemiluminescence signal while at high concentrations (4 x 10(-2) mmol/L) an inhibition of chemiluminescence was observed. To obtain the needed intensity of chemiluminescence no more than 5 daphnia persons is required to incubate in volume of 10 mL of sample for analyzing. The intensity of chemiluminescence of daphnia cultivating medium and the sensitivity of this organism to potassium chromate increased at the temperature increasing from 24 to 32 degrees C. Daphnia cultivating medium can be preserved in refrigerator for several hours without lost of chemiluminescence signal.  相似文献   

4.
Anionic sweet potato peroxidase (SPP; Ipomoea batatas) was shown to efficiently catalyse luminol oxidation by hydrogen peroxide, forming a long-term chemiluminescence (CL) signal. Like other anionic plant peroxidases, SPP is able to catalyse this enzymatic reaction efficiently in the absence of any enhancer. Maximum intensity produced in SPP-catalysed oxidation of luminol was detected at pH 7.8-7.9 to be lower than that characteristic of other peroxidases (8.4-8.6). Varying the concentrations of luminol, hydrogen peroxide and Tris buffer in the reaction medium, we determined favourable conditions for SPP catalysis (100 mmol/L Tris-HCl buffer, pH 7.8, containing 5 mmol/L hydrogen peroxide and 8 mmol/L luminol). The SPP detection limit in luminol oxidation was 1.0 x 10(-14) mol/L. High sensitivity in combination with the long-term CL signal and high stability is indicative of good promise for the application of SPP in CL enzyme immunoassay.  相似文献   

5.
Luminol chemiluminescence was used to evaluate the scavenging of superoxide, hydroxyl and alkoxy radicals by four antioxidants: dipyridamole, diethyldithiocarbamic acid, (+)catechin, and ascorbic acid. Different concentrations of these compounds were compared with well-known oxygen radical scavengers in their capacity to inhibit the chemiluminescence produced in the reaction between luminol and specific oxygen radicals. Hydroxyl radicals were generated using the Fenton reaction and these produced chemiluminescence which was inhibited by diethyldithiocarbamate. Alkoxy radicals were generated using the reaction of tert-butyl hydroperoxide and ferrous ion and produced chemiluminescence which was inhibited equally by all of the compounds tested. For the determination of superoxide scavengers we describe a new, simple, economic, and rapid chemiluminescence method consisting of the reaction between luminol and horseradish peroxidase (HRP). With this method it was found that 40 nmol/l dipyridamole, 0.18 μmol/l ascorbic acid, 0.23 μmol/l (+)catechin, and 3 μmol/l diethyldithiocarbamic acid are equivalent to 3.9 ng/ml superoxide dismutase (specific scavenger of superoxide) in causing the same degree of chemiluminescence inhibition. These results not only indicated that the antioxidative properties of these compounds showed different degrees of effectiveness against a particular radical but also that they may exert their action against more than one radical.  相似文献   

6.
The monitoring of uric acid (UA) and p-aminohippuric acid (PAH) levels in biological samples is routinely carried out in clinical laboratories as an indication of renal disease. With the aim of investigation of the correlation between the trace amounts of UA and PAH in human saliva or urine and renal diseases, we carried out the determination of UA and PAH in human saliva and urine by using capillary electrophoresis with electrochemical detection (CE-ED) in this work. Under the optimum conditions, UA, PAH and three coexisting analytes could be well separated within 21 min at the separation voltage of 14 kV in 80 mmol/L borax running buffer (pH 9.2). Good linear relationship was established between peak current and concentration of analytes over two orders of magnitude with detection limits (S/N = 3) ranged from 5.01 x 10(-7) to 2.00 x 10(-6) mol/L for all analytes. The result shows that this proposed method could be successfully applied for the study on the correlation between the levels of UA and PAH in human saliva and urine and renal diseases, and provide an alternative and convenient method for the fast diagnosis of renal disease.  相似文献   

7.
In this paper we propose a new fast free zone capillary electrophoresis method for the simultaneous determination of ascorbic acid (AA) and uric acid (UA) in human plasma. We investigated the effect of analytical parameters, such as concentration and pH of borate running buffer, cartridge temperature, and sample treatment, on resolution, migration times, corrected peak areas, and efficiency. A good separation was achieved using a 60.2-cmx75-microm uncoated silica capillary and 100 mmol/L sodium borate buffer, pH 8, when metaphosphoric acid was employed as protein precipitant, in less than 4 min. These conditions gave a good reproducibility of migration times (CV 0.35 and 0.34%) and peak areas (CV 3.2 and 3.1%) for ascorbate and urate, respectively. The limit of detection was 0.5mg/L for both analytes when the detection was performed at 254 nm for AA and at 292 nm for UA. We compared the present method with a validated capillary electrophoresis assay by measuring plasma urate and ascorbate in 32 normal subjects and the obtained data were analyzed by the Passing and Bablok regression.  相似文献   

8.
A capillary electrophoretic immunoassay with chemiluminescence detection (CEIA-CL) using a non-competitive format for analyzing tumor marker alpha-fetoprotein (AFP) has been developed. In this method, antigen (Ag) AFP reacts with an excess amount of horseradish peroxidase (HRP)-labeled antibody (Ab*). The free Ab* and the bound Ab*-Ag complex produced in the solution are separated by CE in a separation capillary. Then they catalyze the reaction of enzyme substrate luminol and H(2)O(2) in a reaction capillary following the separation capillary. Parameters affecting the CE separation and CL detection were investigated. Under the optimal conditions, the free Ab* and the Ab*-Ag complex were well separated within 4 min, the linear range and the detection limit (S/N=3) for AFP were 5-500 ng/ml and 0.85 ng/ml (1.2 x 10(-11)M), respectively. The proposed method has been applied satisfactorily in the analysis of human sera samples.  相似文献   

9.
Assays of peroxy compounds are commonly performed after chromatographic separation of analysed mixtures. In high‐performance liquid chromatography (HPLC), solvent reservoirs are sparged by helium or inline vacuum‐degassed in order to control the compressibility of the solvents for efficient pumping. In this study, we investigated the influence of degassing the reaction solution on the light output of the hemin‐catalyzed luminol oxidation by various oxidants. We found that, when t‐butyl hydroperoxide, hydrogen peroxide, n‐butyl hydroperoxide, iodosobenzene and iodobenzene diacetate were used as oxidants, the luminol chemiluminescence was lowered by 50–70% compared with an equilibrated and degassed solution. The opposite effect was observed when dibenzoyl peroxide and 3‐chloroperoxybenzoic acid were used as oxidants, as the chemiluminescence increased by approximately 20–30%. The reduced chemiluminescence was explained based on the known role of dioxygen in luminol chemiluminescence. The enhancement of chemiluminescence was rationalized by suggesting an alternative mechanism of luminol oxidation valid for peroxyacids and diacyl peroxides in which the reaction of a peroxyacid anion with the diazaquinone led to light emission with a higher quantum yield than the usual path, which is suppressed by the removal of dioxygen from the reaction solution. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

10.
《Luminescence》2003,18(5):249-253
We established a peroxynitrite–luminol chemiluminescence system for detecting peroxynitrite in cell culture solution exposed to carbon disulphide (CS2). Three factors, including exposure time to ozone (Factor A), volume of peroxynitrite (ONOO?) solution (Factor B) and luminol concentrations (Factor C) at three levels were selected and the combinations were in accordance with orthogonal design L9 (34). Peroxynitrite was generated from the reaction of ozone and 0.01 mol/L sodium azide (NaN3) dissolved in carbonic acid buffer solution (pH 11), and it was reacted with luminol to yield chemiluminescence. The peak value, peak time and kinetic curve of the light emission were observed. The selected combination conditions were 50 s ozone, 800 µL peroxynitrite and 0.001 mol/L luminol solution. Cell culture solution with CS2 enhanced the emission intensity of chemiluminescence (F = 8.38, p = 0.018) and shortened the peak time to chemiluminescence (F = 139.00, p = 0.0001). The data demonstrated that this luminol chemiluminescence system is suitable for detecting peroxynitrite in cell culture solutions for evaluating the effect of CS2 on endothelial cells. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

11.
《Luminescence》2003,18(2):67-71
A flow injection method for the determination of glycerol using a co‐immobilized enzyme reactor containing glycerokinase and glycerol‐3‐phosphate oxidase is described. The hydrogen peroxide produced is monitored by using a luminol chemiluminescence reaction in the presence of catalyst such as Co(II). The detection limit (2.5 × blank noise) for glycerol is 7 × 10?3 mmol/L with a sample throughput of 40/h. The calibration graph is linear over the range studied (0.2–1.0 mmol/L) with relative standard deviation 1.2–2.4%. The method is applied to the determination of glycerol in blood serum produced off‐line from triglycerides using lipase isolated from bovine pancreas. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

12.
A combined system of chemiluminescence detection and high performance liquid chromatography (CL–HPLC) was developed to determine primary peroxidation products in biological tissues, such as phosphatidylcholine hydroperoxide (PCOOH). The CL–HPLC assay consists of separation of lipid classes with HPLC and detection of hydroperoxide-specific chemiluminescence. Hydroperoxides react with heme compounds to produce oxidants as suggested by our early studies on tissue low-level chemiluminescence in which singlet molecular oxygen is generated as one of the excited species in several biological systems involving free radical events. In the CL–HPLC method, a cytochrome c–luminol mixture was used as a hydroperoxide-specific luminescent reagent, and the quantification of hydroperoxide was performed by detecting chemiluminescence due to the luminol oxidation caused by the oxidant produced during the lipid hydroperoxides with heme. The detection limit of PCOOH was 10 pmole hydroperoxide–O2. PCOOH in normal human blood was found to be 10–500 pmol/ml plasma and significantly higher levels of PCOOH were observed in some hospitalized patients.  相似文献   

13.
A new microflow injection analysis (microFIA) system on a chip coupled with chemiluminescence (CL) for the non-enzymatic determination of uric acid is described. The microFIA system produced by using two transparent poly(methylmethacrylate) (PMMA) chips measured 50 x 40 x 5 mm, the microchannels, etched by CO2 laser, were 200 microm wide and 100 microm deep, and the volume of the reaction area (RA) was about 1.2 microL. The injection pump, with accurate time control, monitored all reagents, including the sample. The uric acid was sensed by the chemiluminescence reaction between luminol and ferricyanide. The linear range of the uric acid concentration was 0.8-30 mg/L and the detection limit was 0.5 mg/L (S/N = 3). The relative standard deviation was 4.42% for 5 mg/L uric acid (n = 8). The proposed method has been successfully applied to the non-separation determination of uric acid in human serum and urine.  相似文献   

14.
The oxidation reaction of luminol with AgNO3 can produce chemiluminescence (CL) in the presence of silver nanoparticles (NPs) in alkaline solution. Based on the studies of UV‐vis absorption spectra, photoluminescence (PL) spectra and CL spectra, a CL enhancement mechanism is proposed. The CL emission spectrum of the luminol–AgNO3–Ag NPs system indicated that the luminophore was still 3‐aminophthalate. On injection of silver nanoparticles into the mixture of luminol and AgNO3, they catalysed the reduction of AgNO3 by luminol. The product luminol radicals reacted with the dissolved oxygen, to produce a strong CL emission. As a result, the CL intensity was substantially increased. Moreover, the influences of 18 amino acids, e.g. cystine, tyrosine and asparagine, and 25 organic compounds, including gallic acid, tannic acid and hydroquinone, on the luminol–AgNO3–Ag NPs CL system were studied by a flow‐injection procedure, which led to an effective method for detecting these compounds. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

15.
The antioxidant activity of a representative series of free, glycine- and taurine-conjugated bile acids was evaluated by two different chemiluminescent assays: (a) the enhanced chemiluminescence system based on horseradish peroxidase and luminol/oxidant/enhancer reagent, and (b) the hypoxanthine/xanthine oxidase/Fe2+-EDTA/luminol system. Bile acids were studied at final concentrations ranging from 1 to 28 mmol/L. All of the bile acids studied inhibited the steady-state chemiluminescent reaction and the extent of inhibition depended upon the structure of the bile acids, whereas the duration was related to bile acid concentration. The mechanism of the light inhibition is probably due to trapping of oxygen free radicals generated in the chemiluminescent reactions, within bile acid micelles. The free radicals trapped into micelles reduced the formation of luminol radicals and consequently the light output; when the micelles were saturated, the oxygen free radicals in solution again produced luminol radicals. The micelle interaction with reactive oxygen species could be a physiological mechanism of defence against the toxicity of those species in the intestinal content. On the other hand, alterations in bile acid organ distribution, concentration and composition leads to a membrane damage caused by their detergent-like properties, which could be associated to oxygen free radical production. © 1998 John Wiley & Sons, Ltd.  相似文献   

16.
A flow injection chemiluminometric assay for urea has been developed based on a minicolumn bioreactor packed with immobilized enzyme-bearing glass beads. The reactor contains immobilized urease, L -glutamate dehydrogenase and L -glutamate oxidase, aligned in this order (upstream to the downstream). When the sample is introduced into the bioreactor, urea is first hydrolysed by urease to produce ammonia, which is then converted into L -glutamate by L -glutamate dehydrogenase. L -Glutamate is finally oxidized by L -glutamate oxidase to produce hydrogen peroxide, which is quantified by measuring chemiluminescence emitted upon admixing with luminol and potassium ferricyanide. One assay cycle is completed within 1 minute. The method is sensitive (detection limit 0.5 nmol) and is linear in the range 0–30 mmol/l. It can be readily applied to the determination of urea in human serum, and requires no blank corrections for ammonia and/or L -glutamate present in serum samples.  相似文献   

17.
Heptanesulfonic acid as ion-pairing agent was used for the separation of mixtures of low and high molecular mass peptides/proteins by capillary electrophoresis. The separation conditions used were: capillary 37 cm (30 cm to the detector) x 75 microm i.d., voltage 10 kV, phosphate buffer 50 mmol/l, ion-pairing agent heptanesulfonic acid at three different concentrations, namely, 0, 20 or 100 mmol/l, pH 2.5. The separation reflected the ion-pairing equilibria between the ion-pairing agent and the peptide/protein analytes. The influence of ion-pairing on sample mobility (running time) was more pronounced in case of the higher-molecular peptides as compared to the low molecular ones. This difference offers the possibility to separate low and high molecular peptides/proteins that under the absence of the ion-pairing agent would co-migrate. The principle of this approach was demonstrated on a randomly selected set of peptides/proteins; the practical applicability was demonstrated on a set of CNBr peptides arising from a naturally occurring mixture of collagen types I and III.  相似文献   

18.
We explored the behaviour of a series of phenolic acids used as enhancers or inhibitors of luminol chemiluminescence by three different methods to determine if behaviour was associated with phenolic acid structure and redox character. All the phenolic acids inhibited chemiluminescence when hexacyanoferrate(III) was reacted with the phenolic acids before adding luminol. The redox character of these compounds was clearly related to structure. When hexacyanoferrate(III)-luminol-O2 chemiluminescence was initiated by phenolic acid-luminol mixtures some phenolic acids behaved as enhancers of chemiluminescence, and others as inhibitors. We propose a mechanism to explain these findings. We found direct relationships between the redox character of the phenolic acids and the enhancement or inhibition of the chemiluminescence of the luminol–H2O2–peroxidase system and we propose mechanism to explain these phenomena.  相似文献   

19.
A new method for the detection of β2 adrenergic agonists was developed based on the chemiluminescence (CL) reaction of β2 adrenergic agonist with potassium ferricyanide–luminol CL. The effect of β2 adrenergic agonists including isoprenaline hydrochloride, salbutamol sulfate, terbutaline sulfate and ractopamine on the CL intensity of potassium ferricyanide–luminol was discovered. Detection of the β2 adrenergic agonist was carried out in a flow system. Using uniform design experimentation, the influence factors of CL were optimized. The optimal experimental conditions were 1 mmol/L of potassium ferricyanide, 10 µmol/L of luminol, 1.2 mmol/L of sodium hydroxide, a flow speed of 2.6 mL/min and a distance of 1.2 cm from ‘Y2’ to the flow cell. The linear ranges and limit of detection were 10–100 and 5 ng/mL for isoprenaline hydrochloride, 20–100 and 5 ng/mL for salbutamol sulfate, 8–200 and 1 ng/mL for terbutaline sulfate, 20–100 and 4 ng/mL for ractopamine, respectively. The proposed method allowed 200 injections/h with excellent repeatability and precision. It was successfully applied to the determination of three β2 adrenergic agonists in commercial pharmaceutical formulations with recoveries in the range of 96.8–98.5%. The possible CL reaction mechanism of potassium ferricyanide–luminol–β2 adrenergic agonist was discussed from the UV/vis spectra. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

20.
It was found that isoniazid (ISO) or p‐aminosalicylic acid (PAS) could enhance the chemiluminescence (CL) emission from Cu (II)‐luminol‐hydrogen peroxide system, and the increased chemiluminescence signals were proportional to their concentrations, respectively. Based on this phenomenon, a chemiluminescence method coupled to capillary electrophoresis (CE) was established for simultaneous determination of ISO and PAS. The CE conditions including running buffer and running voltage were investigated in detail. The effects of the pH of H2O2 solution and the concentrations of luminol, H2O2 and Cu (II) on the CL signal were also investigated carefully. Under the optimized conditions, the analysis could be accomplished within 10 min, with the limits of detection of 0.3 µg mL–1 for ISO and 1.1 µg mL–1 for PAS, corresponding to 7.2 and 26.4 pg per injection (24 nL), respectively. Finally, the method was validated by determining the two analytes in pharmaceutical preparation and spiked human serum samples. The results of pharmaceutical tablet analysis were in good agreement with the labeled amounts. The recoveries for ISO and PAS in human serum were in the range of 92–104% and 90–113%, respectively. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏