首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 350 毫秒
1.
2.
3.
High-sensitivity quantitative PCR platform   总被引:1,自引:0,他引:1  
DeGraves FJ  Gao D  Kaltenboeck B 《BioTechniques》2003,34(1):106-10, 112-5
Real-time PCR methods have become widely used within the past few years. However, real-time PCR is rarely used to study chronic diseases with low pathogen loads, presumably because of insufficient sensitivity. In this report, we developed an integrated nucleic acid isolation and real-time PCR platform that vastly improved the sensitivity of the quantitative detection of the intracellular bacterium, Chlamydia spp., by fluorescence resonance energy transfer real-time PCR. Determinants of the overall detection sensitivity were analyzed by extracting nucleic acids from bovine milk specimens spiked with low amounts of chlamydial organisms. Nucleic acids were optimally preserved and recovered by collection in guanidinium stabilization buffer, binding to a matrix of glass fiber fleece, and elution in low volume. Step-down thermal cycling and an excess of hot-start Taq polymerase vastly improved the robustness and sensitivity of the real-time PCR while essentially maintaining 100% specificity. The amplification of Chlamydia 23S rRNA allowed for the differentiation of chlamydial species and was more robust at low target numbers than amplification of the omp1 gene. The best combined method detected single targets per a 100-microL specimen equivalent in a 5-microL real-time PCR input. In an initial application, this high-sensitivity real-time PCR platform demonstrated a high prevalence of chlamydial infection in cattle.  相似文献   

4.
In this article we present validation of a real-time RT-PCR method to quantitate mRNA expression levels of atrial natriuretic peptide and c-fos in an in vitro model of cardiac hypertrophy. This method requires minimal sample and no postreaction manipulation. In real-time RT-PCR a dual-labeled fluorescent probe is degraded concomitant with PCR amplification. Input target mRNA levels are correlated with the time (measured in PCR cycles) at which the reporter fluorescent emission increases beyond a threshold level. The use of an oligo(dt) magnetic bead protocol to harvest poly(A) mRNA from cultured cells in 96-well plates minimized DNA contamination. We show that the GAPDH gene chosen for normalization of the RNA load is truly invariant throughout the biological treatments examined. We discuss two methods of calculating fold increase: a standard curve method and the DeltaDelta Ct method. Real-time quantitative RT-PCR was used to determine the time course of c-fos induction and the effect of varying doses of four known hypertrophy agents on atrial naturitic factor messenger RNA expression in cultured cardiac muscle cells. Our results agree with published data obtained from Northern blot analysis.  相似文献   

5.
Rapid and accurate detection of plant pathogens in the field is crucial to prevent the proliferation of infected crops. Polymerase chain reaction (PCR) process is the most reliable and accepted method for plant pathogen diagnosis, however current conventional PCR machines are not portable and require additional post-processing steps to detect the amplified DNA (amplicon) of pathogens. Real-time PCR can directly quantify the amplicon during the DNA amplification without the need for post processing, thus more suitable for field operations, however still takes time and require large instruments that are costly and not portable. Microchip PCR systems have emerged in the past decade to miniaturize conventional PCR systems and to reduce operation time and cost. Real-time microchip PCR systems have also emerged, but unfortunately all reported portable real-time microchip PCR systems require various auxiliary instruments. Here we present a stand-alone real-time microchip PCR system composed of a PCR reaction chamber microchip with integrated thin-film heater, a compact fluorescence detector to detect amplified DNA, a microcontroller to control the entire thermocycling operation with data acquisition capability, and a battery. The entire system is 25×16×8 cm3 in size and 843 g in weight. The disposable microchip requires only 8-µl sample volume and a single PCR run consumes 110 mAh of power. A DNA extraction protocol, notably without the use of liquid nitrogen, chemicals, and other large lab equipment, was developed for field operations. The developed real-time microchip PCR system and the DNA extraction protocol were used to successfully detect six different fungal and bacterial plant pathogens with 100% success rate to a detection limit of 5 ng/8 µl sample.  相似文献   

6.
Evaluation of uncertainty in quantitative real-time PCR   总被引:4,自引:0,他引:4  
Quantitative real-time PCR is one of the newer methods for measurement of the amount of nucleic material in biological systems. However, reliable measurement requires an appropriate estimation of uncertainty and this paper has developed the uncertainty budget associated with this procedure using as an example, data from a quantitative real-time PCR method for the enumeration of Campylobacter jejuni. This uncertainty is relatively large and for instance, a measured result of 151 units of DNA would have a 95% confidence interval of +/-84 units of DNA with the main sources of uncertainty being the measurement of the threshold cycle (Ct) value, the predicted DNA content of the unknown sample from the calibration line and the molar absorbance value for DNA.  相似文献   

7.
8.
9.
Adenoviruses 40 and 41 have been recognized as important etiological agents of gastroenteritis in children. A real-time PCR method (TaqMan assay) was developed for rapid quantification of adenovirus 40 (Ad40) by amplifying an 88 bp sequence from the hexon gene. To establish a quantification standard curve, a 1090 bp hexon region of Ad40 was amplified and cloned into the pGEM-T Vector. A direct correlation was observed between the fluorescence threshold cycle number (Ct) and the starting quantity of Ad40 hexon gene. The quantification was linear over 6-log units and the amplification efficiency averaged greater than 95%. Seeding studies using various environmental matrices (including sterile water, creek water, brackish estuarine water, ocean water, and secondary sewage effluent) suggest that this method is applicable to environmental samples. However, real-time PCR was sensitive to inhibitors present in the environmental samples. Lower efficiency of PCR amplification was found in secondary sewage effluent and creek waters. Application of the method to fecal contaminated waters successfully quantified the presence of Ad40. The sensitivity of the real-time PCR is comparable to the traditional nested PCR assay for environmental samples. In addition, the real-time PCR assay offers the advantage of speed and insensitivity to contamination during PCR set up. The real-time PCR assay developed in this study is suitable for quantitative determination of Ad40 in environmental samples and represents a considerable advancement in pathogen quantification in aquatic environments.  相似文献   

10.
11.
12.
Real-time quantitative PCR (qPCR) is a powerful tool for quantifying specific DNA target sequences. Although determination of relative quantity is widely accepted as a reliable means of measuring differences between samples, there are advantages to being able to determine the absolute copy numbers of a given target. One approach to absolute quantification relies on construction of an accurate standard curve using appropriate external standards of known concentration. We have validated the use of tissue genomic DNA as a universal external standard to facilitate quantification of any target sequence contained in the genome of a given species, addressing several key technical issues regarding its use. This approach was applied to validate mRNA expression of gene candidates identified from microarray data and to determine gene copies in transgenic mice. A simple method that can assist achieving absolute quantification of gene expression would broadly enhance the uses of real-time qPCR and in particular, augment the evaluation of global gene expression studies.  相似文献   

13.
14.
Real-time PCR is being used increasingly as the method of choice for mRNA quantification, allowing rapid analysis of gene expression from low quantities of starting template. Despite a wide range of approaches, the same principles underlie all data analysis, with standard approaches broadly classified as either absolute or relative. In this study we use a variety of absolute and relative approaches of data analysis to investigate nocturnal c-fos expression in wild-type and retinally degenerate mice. In addition, we apply a simple algorithm to calculate the amplification efficiency of every sample from its amplification profile. We confirm that nocturnal c-fos expression in the rodent eye originates from the photoreceptor layer, with around a 5-fold reduction in nocturnal c-fos expression in mice lacking rods and cones. Furthermore, we illustrate that differences in the results obtained from absolute and relative approaches are underpinned by differences in the calculated PCR efficiency. By calculating the amplification efficiency from the samples under analysis, comparable results may be obtained without the need for standard curves. We have automated this method to provide a means of streamlining the real-time PCR process, enabling analysis of experimental samples based upon their own reaction kinetics rather than those of artificial standards.  相似文献   

15.
In vitro selection of proteins from cDNA libraries using display technologies, such as the in vitro virus method, is a powerful means for the discovery of novel protein interactions. After iterative screening, selected proteins are usually identified and evaluated by cloning and sequencing analysis. Previously we applied real-time PCR for evaluation of the sequences obtained on in vitro virus screening. Here, we have presented additional data regarding monitoring of the process of enrichment of selected clones in each round of selection and elimination of false positives by real-time PCR, and have also discussed the utility of the novel method. This approach should also be applicable to other display technologies.  相似文献   

16.
17.
18.
19.
Quantification of circulating nucleic acids in plasma and serum could be used as a non-invasive diagnostic tool for monitoring a wide variety of diseases and conditions. We describe here a rapid, simple and accurate multiplex real-time PCR method for direct synchronized analysis of circulating cell-free (ccf) mitochondrial (mtDNA) and nuclear (nDNA) DNA in plasma and serum samples. The method is based on one-step multiplex real-time PCR using a FAM-labeled MGB probe and primers to amplify the mtDNA sequence of the ATP 8 gene, and a VIC-labeled MGB probe and primers to amplify the nDNA sequence of the glycerinaldehyde-3-phosphate-dehydrogenase (GAPDH) gene, in plasma and serum samples simultaneously. The efficiencies of the multiplex assays were measured in serial dilutions. Based on the simulation of the PCR reaction kinetics, the relative quantities of ccf mtDNA were calculated using a very simple equation. Using our optimised real-time PCR conditions, close to 100% efficiency was obtained from the two assays. The two assays performed in the dilution series showed very good and reproducible correlation to each other. This optimised multiplex real-time PCR protocol can be widely used for synchronized quantification of mtDNA and nDNA in different samples, with a very high rate of efficiency.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号