首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.

Background

Cholera, an ancient scourge, continues to inflict high rates of mortality today. The rising incidence of epidemics in areas of poor sanitation and crowding highlight the need for better epidemic prevention and early response. Such interventions require the availability of rapid and accurate diagnostic techniques to trigger timely response and mitigate the scale of the outbreak. The current gold standard of bacterial culture is inadequate for rapid diagnosis, highlighting the overarching neglect of field diagnostic needs. This paper was written to support the World Health Organisation''s Global Task Force on Cholera Control mandated Cholera and diarrhoeal disease laboratory Network (CholdiNet) in devising a protocol for the validation of Rapid Diagnostic Tests (RDTs) for Vibrio cholerae. The status of diagnostic tools for Vibrio cholerae is assessed, describing products that have been commercialised over the last two decades and discussing their peer-reviewed evaluation.

Method

Review of post-1990 peer-reviewed and grey literature on rapid diagnostic tests for Vibrio cholerae.

Results

Since 1990, twenty four diagnostic tests have been developed for the detection of Vibrio cholerae in human faecal samples. Fourteen of these have also been described in the literature, with rapid chromatographic-immuno assays (CIA) featuring strongly. Polymerase chain reaction (PCR) assays maintain the ability to detect the lowest amount of bacteria; however CIAs achieve both low detection thresholds and high sensitivity and specificity, making them possible candidates for use in field conditions. Field and laboratory studies were performed in a wide range of settings demonstrating variability in performance, however only a few of these studies were sufficiently stringent, highlighting five RDTs that showed promise in field conditions; COAT, IP cholera dipstick, SMART, IP dipstick and Medicos. In light of non-independent reporting, the authors would like to see these five products undergoing additional studies, with further technical improvements if needed and commercial production. The authors hope that public health use of such a RDT in limited-resource field conditions on stool samples may contribute to effective reduction in cholera epidemic spread.  相似文献   

2.
BackgroundLittle is known about the diagnostic performance of rapid diagnostic tests (RDTs) for passive screening of human African trypanosomiasis (HAT) in Côte d’Ivoire. We determined HAT prevalence among clinical suspects, identified clinical symptoms and signs associated with HAT RDT positivity, and assessed the diagnostic tests’ specificity, positive predictive value and agreement.MethodsClinical suspects were screened with SD Bioline HAT, HAT Sero-K-Set and rHAT Sero-Strip. Seropositives were parasitologically examined, and their dried blood spots tested in trypanolysis, ELISA/Tbg, m18S-qPCR and LAMP. The HAT prevalence in the study population was calculated based on RDT positivity followed by parasitological confirmation. The association between clinical symptoms and signs and RDT positivity was determined using multivariable logistic regression. The tests’ Positive Predictive Value (PPV), specificity and agreement were determined.ResultsOver 29 months, 3433 clinical suspects were tested. The RDT positivity rate was 2.83%, HAT prevalence 0.06%. Individuals with sleep disturbances (p<0.001), motor disorders (p = 0.002), convulsions (p = 0.02), severe weight loss (p = 0.02) or psychiatric problems (p = 0.04) had an increased odds (odds ratios 1.7–4.6) of being HAT RDT seropositive. Specificities ranged between 97.8%-99.6% for individual RDTs, and 93.3–98.9% for subsequent tests on dried blood spots. The PPV of the individual RDTs was below 14.3% (CI 2–43), increased to 33.3% (CI 4–78) for serial RDT combinations, and reached 67% for LAMP and ELISA/Tbg on RDT positives. Agreement between diagnostic tests was poor to moderate (Kappa ≤ 0.60), except for LAMP and ELISA/Tbg (Kappa = 0.66).ConclusionIdentification of five key clinical symptoms and signs may simplify referral for HAT RDT screening. The results confirm the appropriateness of the diagnostic algorithm presently applied, with screening by SD Bioline HAT or HAT Sero-K-Set, supplemented with trypanolysis. ELISA/Tbg could replace trypanolysis and is simpler to perform.Trial registrationClinicalTrials.gov NCT03356665.  相似文献   

3.

Background

Although rapid diagnostic tests (RDTs) have practical advantages over light microscopy (LM) and good sensitivity in severe falciparum malaria in Africa, their utility where severe non-falciparum malaria occurs is unknown. LM, RDTs and polymerase chain reaction (PCR)-based methods have limitations, and thus conventional comparative malaria diagnostic studies employ imperfect gold standards. We assessed whether, using Bayesian latent class models (LCMs) which do not require a reference method, RDTs could safely direct initial anti-infective therapy in severe ill children from an area of hyperendemic transmission of both Plasmodium falciparum and P. vivax.

Methods and Findings

We studied 797 Papua New Guinean children hospitalized with well-characterized severe illness for whom LM, RDT and nested PCR (nPCR) results were available. For any severe malaria, the estimated prevalence was 47.5% with RDTs exhibiting similar sensitivity and negative predictive value (NPV) to nPCR (≥96.0%). LM was the least sensitive test (87.4%) and had the lowest NPV (89.7%), but had the highest specificity (99.1%) and positive predictive value (98.9%). For severe falciparum malaria (prevalence 42.9%), the findings were similar. For non-falciparum severe malaria (prevalence 6.9%), no test had the WHO-recommended sensitivity and specificity of >95% and >90%, respectively. RDTs were the least sensitive (69.6%) and had the lowest NPV (96.7%).

Conclusions

RDTs appear a valuable point-of-care test that is at least equivalent to LM in diagnosing severe falciparum malaria in this epidemiologic situation. None of the tests had the required sensitivity/specificity for severe non-falciparum malaria but the number of false-negative RDTs in this group was small.  相似文献   

4.
Rapid diagnostic tests (RDT) are valuable tools that support prudent and timely use of antimalarial drugs, particularly if reliable microscopy is not available. However, the performance and reliability of these tests vary between and within geographical regions. The present study evaluated the performance of routine malaria RDT in Kenyan febrile patients in Busia County, Kenya. A cross sectional study design was employed to recruit febrile patients attending health facilities between August and November 2016. A total of 192 febrile patients who were slide positive and negative were evaluated for their infection status by nested PCR and RDTs (PfHRP2/pLDH). In addition, P. falciparum diversity of the histidine-rich proteins 2 and 3, that influences the RDT test results were determined. All individuals were P. falciparum positive. Among the investigated 192 febrile patients, 76 (40%) were positive by microscopy, 101 (53%) by RDTs and 80 (42%) were PCR positive. The performance of the CareStart? HRP2/pLDH (pf) RDTs was better than microscopy (Sensitivity 94%; Specificity 75%) and Nucleic acid testing (sensitivity 95%, specificity 77%) with high negative predictive values, indicating the suitability of the RDT in routine practice. Specific pfhrp2/pfhrp3 deletions shown to associate with RDT false negativity was not observed. However, high genetic diversity among pfhrp2 gene was observed. Eleven new PfHRP2 and nine PfHRP3 repeats were observed. False positivity by microscopy and under reporting of infections may thus be a barrier in malaria control and elimination programs. The HRP2/pLDH(Pf) based RDT yet demonstrate to be an effective tool for malaria surveillance program.  相似文献   

5.

Background

In the Peruvian Amazon, Plasmodium falciparum and Plasmodium vivax malaria are endemic in rural areas, where microscopy is not available. Malaria rapid diagnostic tests (RDTs) provide quick and accurate diagnosis. However, pfhrp2 gene deletions may limit the use of histidine-rich protein-2 (PfHRP2) detecting RDTs. Further, cross-reactions of P. falciparum with P. vivax-specific test lines and vice versa may impair diagnostic specificity.

Methods

Thirteen RDT products were evaluated on 179 prospectively collected malaria positive samples. Species diagnosis was performed by microscopy and confirmed by PCR. Pfhrp2 gene deletions were assessed by PCR.

Results

Sensitivity for P. falciparum diagnosis was lower for PfHRP2 compared to P. falciparum-specific Plasmodium lactate dehydrogenase (Pf-pLDH)- detecting RDTs (71.6% vs. 98.7%, p<0.001). Most (19/21) false negative PfHRP2 results were associated with pfhrp2 gene deletions (25.7% of 74 P. falciparum samples). Diagnostic sensitivity for P. vivax (101 samples) was excellent, except for two products. In 10/12 P. vivax-detecting RDT products, cross-reactions with the PfHRP2 or Pf-pLDH line occurred at a median frequency of 2.5% (range 0%–10.9%) of P. vivax samples assessed. In two RDT products, two and one P. falciparum samples respectively cross-reacted with the Pv-pLDH line. Two Pf-pLDH/pan-pLDH-detecting RDTs showed excellent sensitivity with few (1.0%) cross-reactions but showed faint Pf-pLDH lines in 24.7% and 38.9% of P. falciparum samples.

Conclusion

PfHRP2-detecting RDTs are not suitable in the Peruvian Amazon due to pfhrp2 gene deletions. Two Pf-pLDH-detecting RDTs performed excellently and are promising RDTs for this region although faint test lines are of concern.  相似文献   

6.
In recent years, rapid diagnostic tests (RDTs) have been widely used for malaria detection, primarily because of their simple operation, fast results, and straightforward interpretation. The Asan EasyTest™ Malaria Pf/Pan Ag is one of the most commonly used malaria RDTs in several countries, including Korea and India. In this study, we tested the diagnostic performance of this RDT in Uganda to evaluate its usefulness for field diagnosis of malaria in this country. Microscopic and PCR analyses, and the Asan EasyTest™ Malaria Pf/Pan Ag rapid diagnostic test, were performed on blood samples from 185 individuals with suspected malaria in several villages in Uganda. Compared to the microscopic analysis, the sensitivity of the RDT to detect malaria infection was 95.8% and 83.3% for Plasmodium falciparum and non-P. falciparum, respectively. Although the diagnostic sensitivity of the RDT decreased when parasitemia was ≤500 parasites/µl, it showed 96.8% sensitivity (98.4% for P. falciparum and 93.8% for non-P. falciparum) in blood samples with parasitemia ≥100 parasites/µl. The specificity of the RDT was 97.3% for P. falciparum and 97.3% for non-P. falciparum. These results collectively suggest that the accuracy of the Asan EasyTest™ Malaria Pf/Pan Ag makes it an effective point-of-care diagnostic tool for malaria in Uganda.  相似文献   

7.
8.

Background

Accurate parasitological diagnosis of malaria is essential for targeting treatment where more than one species coexist. In this study, three rapid diagnostic tests (RDTs) (AccessBio CareStart (CSPfPan), CareStart PfPv (CSPfPv) and Standard Diagnostics Bioline (SDBPfPv)) were evaluated for their ability to detect natural Plasmodium vivax infections in a basic clinic setting. The potential for locally made evaporative cooling boxes (ECB) to protect the tests from heat damage in high summer temperatures was also investigated.

Methods

Venous blood was drawn from P. vivax positive patients in Jalalabad, Afghanistan and tested against a panel of six RDTs. The panel comprised two of each test type; one group was stored at room temperature and the other in an ECB. RDT results were evaluated against a consensus gold standard based on two double-read reference slides and PCR. The sensitivity, specificity and a measure of global performance for each test were determined and stratified by parasitaemia level and storage condition.

Results

In total, 306 patients were recruited, of which 284 were positive for P. vivax, one for Plasmodium malariae and none for Plasmodium falciparum; 21 were negative. All three RDTs were specific for malaria. The sensitivity and global performance index for each test were as follows: CSPfPan [98.6%, 95.1%], CSPfPv [91.9%, 90.5%] and SDBPfPv [96.5%, 82.9%], respectively. CSPfPv was 16% less sensitive to a parasitaemia below 5,000/μL. Room temperature storage of SDBPfPv led to a high proportion of invalid results (17%), which reduced to 10% in the ECB. Throughout the testing period, the ECB maintained ~8°C reduction over ambient temperatures and never exceeded 30°C.

Conclusions

Of the three RDTs, the CSPfPan test was the most consistent and reliable, rendering it appropriate for this P. vivax predominant region. The CSPfPv test proved unsuitable owing to its reduced sensitivity at a parasitaemia below 5,000/μL (affecting 43% of study samples). Although the SDBPfPv device was more sensitive than the CSPfPv test, its invalid rate was unacceptably high. ECB storage reduced the proportion of invalid results for the SDBPfPv test, but surprisingly had no impact on RDT sensitivity at low parasitaemia.  相似文献   

9.
10.

Background

Malaria presents a diagnostic challenge in areas where both Plasmodium falciparum and P.vivax are co-endemic. Bivalent Rapid Diagnostic tests (RDTs) showed promise as diagnostic tools for P.falciparum and P.vivax. To assist national malaria control programme in the selection of RDTs, commercially available seven malaria RDTs were evaluated in terms of their performance with special reference to heat stability.

Methodology/Principal Findings

This study was undertaken in four forested districts of central India (July, 2011– March, 2012). All RDTs were tested simultaneously in field along with microscopy as gold standard. These RDTs were stored in their original packing at 25°C before transport to the field or they were stored at 35°C and 45°C upto 100 days for testing the performance of RDTs at high temperature. In all 2841 patients with fever were screened for malaria of which 26% were positive for P.falciparum, and 17% for P.vivax. The highest sensitivity of any RDT for P.falciparum was 98% (95% CI; 95.9–98.8) and lowest sensitivity was 76% (95% CI; 71.7–79.6). For P.vivax highest and lowest sensitivity for any RDT was 80% (95% CI; 94.9 - 83.9) and 20% (95% CI; 15.6–24.5) respectively. Heat stability experiments showed that most RDTs for P.falciparum showed high sensitivity at 45°C upto 90 days. While for P.vivax only two RDTs maintained good sensitivity upto day 90 when compared with RDTs kept at room temperature. Agreement between observers was excellent for positive and negative readings for both P.falciparum and P.vivax (Kappa >0.6–0.9).

Conclusion

This is first field evaluation of RDTs regarding their temperature stability. Although RDTs are useful as diagnostic tool for P.falciparum and P.vivax even at high temperature, the quality of RDTs should be regulated and monitored more closely.  相似文献   

11.

Background

In endemic settings, diagnosis of malaria increasingly relies on the use of rapid diagnostic tests (RDTs). False positivity of such RDTs is poorly documented, although it is especially relevant in those infections that resemble malaria, such as human African trypanosomiasis (HAT). We therefore examined specificity of malaria RDT products among patients infected with Trypanosoma brucei gambiense.

Methodology/Principal Findings

Blood samples of 117 HAT patients and 117 matched non-HAT controls were prospectively collected in the Democratic Republic of the Congo. Reference malaria diagnosis was based on real-time PCR. Ten commonly used malaria RDT products were assessed including three two-band and seven three-band products, targeting HRP-2, Pf-pLDH and/or pan-pLDH antigens. Rheumatoid factor was determined in PCR negative subjects. Specificity of the 10 malaria RDT products varied between 79.5 and 100% in HAT-negative controls and between 11.3 and 98.8% in HAT patients. For seven RDT products, specificity was significantly lower in HAT patients compared to controls. False positive reactions in HAT were mainly observed for pan-pLDH test lines (specificities between 13.8 and 97.5%), but also occurred frequently for the HRP-2 test line (specificities between 67.9 and 98.8%). The Pf-pLDH test line was not affected by false-positive lines in HAT patients (specificities between 97.5 and 100%). False positivity was not associated to rheumatoid factor, detected in 7.6% of controls and 1.2% of HAT patients.

Conclusions/Significance

Specificity of some malaria RDT products in HAT was surprisingly low, and constitutes a risk for misdiagnosis of a fatal but treatable infection. Our results show the importance to assess RDT specificity in non-targeted infections when evaluating diagnostic tests.  相似文献   

12.
Background: Leptospirosis is a growing public health concern in many tropical and subtropical countries. However, its diagnosis is difficult because of non-specific symptoms and concurrent other endemic febrile diseases. In many regions, the laboratory diagnosis is not available due to a lack of preparedness and simple diagnostic assay or difficult access to reference laboratories. Yet, an early antibiotic treatment is decisive to the outcome. The need for Rapid Diagnostic Tests (RDTs) for bedside diagnosis of leptospirosis has been recognized. We developed a vertical flow immunochromatography strip RDT detecting anti-Leptospira human IgM and evaluated it in patients from New Caledonia, France, and French West Indies. Methodology/Principal Findings: Whole killed Leptospira fainei cells were used as antigen for the test line and purified human IgM as the control line. The mobile phase was made of gold particles conjugated with goat anti-human IgM. Standards for Reporting of Diagnostic Accuracy criteria were used to assess the performance of this RDT. The Microscopic Agglutination Test (MAT) was used as the gold standard with a cut-off titer of ≥400. The sensitivity was 89.8% and the specificity 93.7%. Positive and negative Likelihood Ratios of 14.18 and 0.108 respectively, and a Diagnostic Odds Ratio of 130.737 confirmed its usefulness. This RDT had satisfactory reproducibility, repeatability, thermal tolerance and shelf-life. The comparison with MAT evidenced the earliness of the RDT to detect seroconversion. When compared with other RDT, the Vertical Flow RDT developed displayed good diagnostic performances.

Conclusions/Significance

This RDT might be used as a point of care diagnostic tool in limited resources countries. An evaluation in field conditions and in other epidemiological contexts should be considered to assess its validity over a wider range of serogroups or when facing different endemic pathogens. It might prove useful in endemic contexts or outbreak situations.  相似文献   

13.

Background

Individual rapid tests for serodiagnosis (RDT) of human African trypanosomiasis (HAT) are particularly suited for passive screening and surveillance. However, so far, no large scale evaluation of RDTs has been performed for diagnosis of Trypanosoma brucei gambiense HAT in West Africa. The objective of this study was to assess the diagnostic accuracy of 2 commercial HAT-RDTs on stored plasma samples from West Africa.

Methodology/Principal findings

SD Bioline HAT and HAT Sero-K-Set were performed on 722 plasma samples originating from Guinea and Côte d’Ivoire, including 231 parasitologically confirmed HAT patients, 257 healthy controls, and 234 unconfirmed individuals whose blood tested antibody positive in the card agglutination test but negative by parasitological tests. Immune trypanolysis was performed as a reference test for trypanosome specific antibody presence. Sensitivities in HAT patients were respectively 99.6% for SD Bioline HAT, and 99.1% for HAT Sero-K-Set, specificities in healthy controls were respectively 87.9% and 88.3%. Considering combined positivity in both RDTs, increased the specificity significantly (p≤0.0003) to 93.4%, while 98.7% sensitivity was maintained. Specificities in controls were 98.7–99.6% for the combination of one or two RDTs with trypanolysis, maintaining a sensitivity of at least 98.1%.

Conclusions/Significance

The observed specificity of the single RDTs was relatively low. Serial application of SD Bioline HAT and HAT Sero-K-Set might offer superior specificity compared to a single RDT, maintaining high sensitivity. The combination of one or two RDTs with trypanolysis seems promising for HAT surveillance.  相似文献   

14.
BackgroundRapid diagnostic tests (RDTs) have become widely used in low-resource settings for leptospirosis diagnostic. This study aims to evaluate the diagnostic performance of the five commercially available RDTs to detect human IgM against Leptospira spp. in Thai population.Methodology/Principal findingsNinety-nine serum samples from Leptospirosis suspicious patients were tested with five RDTs, including Medical Science Public Health, Leptocheck-WB, SD bioline, TRUSTline, and J.Mitra. The case definition was based on MAT, qPCR, and culture results. Diagnostic accuracy was determined based on the first day of enrollment in an overall analysis and stratified according to days post-onset of fever. The five RDTs had overall sensitivity ranging from 1.8% to 75% and specificity ranging from 52.3% to 97.7%. Leptocheck-WB had high sensitivity of 75.0%. The sensitivity of five RDTs increased on days 4–6 post-onset of fever, while the specificity of all tests remained relatively stable at different days post-onset of fever.Conclusions/SignificanceThe tested RDTs showed low sensitivity. Therefore, based on the present study, five commercially available RDTs might not be an appropriate test for acute leptospirosis screening in the Thai population.  相似文献   

15.
Yaws is a non-venereal treponemal infection caused by Treponema pallidum ssp. pertenue. The WHO has launched a worldwide control programme, which aims to eradicate yaws by 2020. The development of a rapid diagnostic test (RDT) for serological diagnosis in the isolated communities affected by yaws is a key requirement for the successful implementation of the WHO strategy. We conducted a study to evaluate the utility of the DPP test in screening for yaws, utilizing samples collected as part of a community prevalence survey conducted in the Solomon Islands. 415 serum samples were tested using both traditional syphilis serology (TPPA and quantitative RPR) and the Chembio DPP Syphilis Screen and Confirm RDT. We calculated the sensitivity and specificity of the RDT as compared to gold standard serology. The sensitivity of the RDT against TPPA was 58.5% and the specificity was 97.6%. The sensitivity of the RDT against RPR was 41.7% and the specificity was 95.2%. The sensitivity of the DPP was strongly related to the RPR titre with a sensitivity of 92.0% for an RPR titre of >1/16. Wider access to DPP testing would improve our understanding of worldwide yaws case reporting and the test may play a key role in assessing patients presenting with yaws like lesions in a post-mass drug administration (MDA) setting.  相似文献   

16.
Microscopy is considered as the gold standard for malaria diagnosis although its wide application is limited by the requirement of highly experienced microscopists. PCR and serological tests provide efficient diagnostic performance and have been applied for malaria diagnosis and research. The aim of this study was to investigate the diagnostic performance of nested PCR and a recently developed an ELISA-based new rapid diagnosis test (RDT), NovaLisa test kit, for diagnosis of malaria infection, using microscopic method as the gold standard. The performance of nested-PCR as a malaria diagnostic tool is excellent with respect to its high accuracy, sensitivity, specificity, and ability to discriminate Plasmodium species. The sensitivity and specificity of nested-PCR compared with the microscopic method for detection of Plasmodium falciparum, Plasmodium vivax, and P. falciparum/P. vivax mixed infection were 71.4 vs 100%, 100 vs 98.7%, and 100 vs 95.0%, respectively. The sensitivity and specificity of the ELISA-based NovaLisa test kit compared with the microscopic method for detection of Plasmodium genus were 89.0 vs 91.6%, respectively. NovaLisa test kit provided comparable diagnostic performance. Its relatively low cost, simplicity, and rapidity enables large scale field application.  相似文献   

17.
Early diagnosis and appropriate treatment are key elements of malaria control programs in endemic areas. A major step forward in recent years has been the production and use of rapid diagnostic tests (RDTs) in settings where microscopy is impracticable. Many current RDTs target the Plasmodium falciparum histidine-rich protein 2 (PfHRP2) released in the plasma of infected individuals. These RDTs have had an indisputably positive effect on malaria management, but still present several limitations, including the poor characterization of the commercial monoclonal antibodies (mAbs) used for PfHRP2 detection, variable sensitivity and specificity and high costs. RDT use is further limited by impaired stability caused by temperature fluctuations during transport and uncontrolled storage in field-based facilities. To circumvent such drawbacks, an alternative could be the development of well-characterized, stabilized recombinant antibodies, with high binding affinity and specificity. Here, we report the characterization of the cDNA sequences encoding the Fab fragment of F1110 and F1546, two novel anti-PfHRP2 mAbs. FabF1546 was produced in the Escherichia coli periplasm. Its properties of binding to the parasite and to a recombinant PfHRP-2 antigen were similar to those of the parental mAb. As the affinity and stability of recombinant antibodies can be improved by protein engineering, our results open a novel approach for the development of an improved RDT for malaria diagnosis.Key words: Plasmodium falciparum, malaria, histidine-rich protein, monoclonal antibodies, recombinant Fab, rapid diagnostic test  相似文献   

18.
BackgroundCharacterising dengue virus (DENV) infection history at the point of care is challenging as it relies on intensive laboratory techniques. We investigated how combining different rapid diagnostic tests (RDTs) can be used to accurately determine the primary and post-primary DENV immune status of reporting patients during diagnosis.Methods and findingsSerum from cross-sectional surveys of acute suspected dengue patients in Indonesia (N:200) and Vietnam (N: 1,217) were assayed using dengue laboratory assays and RDTs. Using logistic regression modelling, we determined the probability of being DENV NS1, IgM and IgG RDT positive according to corresponding laboratory viremia, IgM and IgG ELISA metrics. Laboratory test thresholds for RDT positivity/negativity were calculated using Youden’s J index and were utilized to estimate the RDT outcomes in patients from the Philippines, where only data for viremia, IgM and IgG were available (N:28,326). Lastly, the probabilities of being primary or post-primary according to every outcome using all RDTs, by day of fever, were calculated. Combining NS1, IgM and IgG RDTs captured 94.6% (52/55) and 95.4% (104/109) of laboratory-confirmed primary and post-primary DENV cases, respectively, during the first 5 days of fever. Laboratory test predicted, and actual, RDT outcomes had high agreement (79.5% (159/200)). Among patients from the Philippines, different combinations of estimated RDT outcomes were indicative of post-primary and primary immune status. Overall, IgG RDT positive results were confirmatory of post-primary infections. In contrast, IgG RDT negative results were suggestive of both primary and post-primary infections on days 1–2 of fever, yet were confirmatory of primary infections on days 3–5 of fever.ConclusionWe demonstrate how the primary and post-primary DENV immune status of reporting patients can be estimated at the point of care by combining NS1, IgM and IgG RDTs and considering the days since symptoms onset. This framework has the potential to strengthen surveillance operations and dengue prognosis, particularly in low resource settings.  相似文献   

19.
BackgroundSoil-transmitted helminths (STHs) are parasitic nematodes that inhabit the human intestine. They affect more than 1.5 billion people worldwide, causing physical and cognitive impairment in children. The global strategy to control STH infection includes periodic mass drug administration (MDA) based on the results of diagnostic testing among populations at risk, but the current microscopy method for detecting infection has diminished sensitivity as the intensity of infection decreases. Thus, improved diagnostic tools are needed to support decision-making for STH control programs.MethodologyWe developed a nucleic acid amplification test based on recombinase polymerase amplification (RPA) technology to detect STH in stool. We designed primers and probes for each of the four STH species, optimized the assay, and then verified its performance using clinical stool samples.Principal findingsEach RPA assay was as sensitive as a real-time polymerase chain reaction (PCR) assay in detecting copies of cloned target DNA sequences. The RPA assay amplified the target in DNA extracted from human stool samples that were positive for STH based on the Kato-Katz method, with no cross-reactivity of the non-target genomic DNA. When tested with clinical stool samples from patients with infections of light, moderate, and heavy intensity, the RPA assays demonstrated performance comparable to that of real-time PCR, with better results than Kato-Katz. This new rapid, sensitive and field-deployable method for detecting STH infections can help STH control programs achieve their goals.ConclusionsSemi-quantitation of target by RPA assay is possible and is comparable to real-time PCR. With proper instrumentation, RPA assays can provide robust, semi-quantification of STH DNA targets as an alternative field-deployable indicator to counts of helminth eggs for assessing infection intensity.  相似文献   

20.
Greece, a malaria-free country since 1974, has experienced re-emergence of Plasmodium vivax autochthonous malaria cases in some agriculture areas over the last three years. In early 2012, an integrated control programme (MALWEST Project) was launched in order to prevent re-establishment of the disease. In the context of this project, the rapid diagnostic tests (RDT) of SD Bioline Malaria Ag Pf/Pan that detects hrp-2 and pan-LDH antigens were used. The aim of this study was to assess the field application of the RDT for the P. vivax diagnosis in comparison to light microscopy and polymerase chain reaction (PCR). A total of 955 samples were tested with all three diagnostic tools. Agreement of RDT against microscopy and PCR for the diagnosis of P. vivax was satisfactory (K value: 0.849 and 0.976, respectively). The sensitivity, specificity and positive predictive value of RDT against PCR was 95.6% (95% C.I.: 84.8-99.3), 100% (95% C.I.: 99.6-100.0) and 100% (95% CI: 91.7-100.0) respectively, while the sensitivity, specificity and positive predictive value of RDT against microscopic examination was 97.4% (95% C.I.: 86.1-99.6), 99.4% (95% C.I.: 98.6-99.8) and 86.1% (95% CI: 72.1-94.7), respectively. Our results indicate that RDT performed satisfactory in a non-endemic country and therefore is recommended for malaria diagnosis, especially in areas where health professionals lack experience on light microscopy.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏