首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
The thermodynamic restrictions on the elastic coefficients of linear orthotropic elasticity and linear transversely isotropy elasticity are recorded and it is shown that previously reported data for the elastic orthotropic constants of bone satisfy these thermodynamic restrictions.  相似文献   

2.
Errors induced by off-axis measurement of the elastic properties of bone   总被引:1,自引:0,他引:1  
Misalignment between the axes of measurement and the material symmetry axes of bone causes error in anisotropic elastic property measurements. Measurements of Poisson's ratio were strongly affected by misalignment errors. The mean errors in the measured Young's moduli were 9.5 and 1.3 percent for cancellous and cortical bone, respectively, at a misalignment angle of 10 degrees. Mean errors of 1.1 and 5.0 percent in the measured shear moduli for cancellous and cortical bone, respectively, were found at a misalignment angle of 10 degrees. Although, cancellous bone tissue was assumed to have orthotropic elastic symmetry, the possibility of the greater symmetry of transverse isotropy was investigated. When the nine orthotropic elastic constants were forced to approximate the five transverse isotropic elastic constants, errors of over 60 percent were introduced. Therefore, it was concluded that cancellous bone is truly orthotropic and not transversely isotropic. A similar but less strong result for cortical bone tissue was obtained.  相似文献   

3.
A two-level micromechanical model of cortical bone based on a generalized self-consistent method was developed to take into consideration the transversely isotropic elasticity of many microstructural features in cortical bone, including Haversian canals, resorption cavities, and osteonal and interstitial lamellae. In the first level, a single osteon was modeled as a two-phase composite such that Haversian canals were represented by elongated pores while the surrounding osteonal lamellae were considered as matrix. In the second level, osteons and resorption cavities were modeled as multiple inclusions while interstitial lamellae were regarded as matrix. The predictions of cortical bone elasticity from this two-level micromechanical model were mostly in agreement with experimental data for the dependence of transversely isotropic elasticity of human femoral cortical bone on porosity. However, variation in cortical bone elastic constants was greater in experimental data than in model predictions. This could be attributed to variations in the elastic properties of microstructural features in cortical bone. The present micromechanical model of cortical bone will be useful in understanding the contribution of cortical bone porosity to femoral neck fractures.  相似文献   

4.
It has been proposed that the orthotropic elastic constants of cancellous bone depend upon a tensorial measure of anisotropy called fabric as well as the tissue's structural density. Cowin (1985, Mechanics Mater, 4, 137-147; 1986, J. biomech. Engng 108, 83-88) developed explicit relationships for the elastic constant, structural density and fabric relationship. In this study the orthotropic elastic moduli, structural density, and fabric components were measured for 11 cancellous bone specimens from five bovine femora and for 75 specimens from three human proximal tibiae and fitted to these relationships using a least squares analysis. The relationships explained between 72 and 94% of the variance in the elastic constants. The relationships between the elastic constants and squared or cubed power functions of structural density had better predictive value over the entire distribution of the data than did expressions with linear functions of structural density.  相似文献   

5.
6.
Finite element models have been widely employed in an effort to quantify the stress and strain distribution around implanted prostheses and to explore the influence of these distributions on their long-term stability. In order to provide meaningful predictions, such models must contain an appropriate reflection of mechanical properties. Detailed geometrical and density information is now readily available from CT scanning. However, despite the use of phantoms, a method of determining mechanical properties (or elastic constants) from bone density has yet to be made available in a usable form.In this study, a cadaveric bone was CT scanned and its natural frequencies were measured using modal analysis. Using the geometry obtained from the CT scan data, a finite element mesh was created with the distribution of density established by matching the mass of the FE bone model with the mass of the cadaveric bone. The maximum values of the orthotropic elastic constants were then established by matching the predictions from FE modal analyses to the experimental natural frequencies, giving a maximum error of 7.8% over 4 modes of vibration. Finally, the elastic constants of the bone derived from the analyses were compared with those measured using ultrasound techniques. This produced a difference of <1% for both the maximum density and axial Young's Modulus. This study has thereby produced an orthotropic finite element model of a human femur. More importantly, however, is the implication that it is possible to create a valid FE model by simply comparing the FE results with the measured resonant frequency of the CT scanned bone.  相似文献   

7.
We studied the elastic properties of bone to analyze its mechanical behavior. The basic principles of ultrasonic methods are now well established for varying isotropic media, particularly in the field of biomedical engineering. However, little progress has been made in its application to anisotropic materials. This is largely due to the complex nature of wave propagation in these media. In the present study, the theory of elastic waves is essential because it relates the elastic moduli of a material to the velocity of propagation of these waves along arbitrary directions in a solid. Transducers are generally placed in contact with the samples which are often cubes with parallel faces that are difficult to prepare. The ultrasonic method used here is original, a rough preparation of the bone is sufficient and the sample is rotated. Moreover, to analyze heterogeneity of the structure we measure velocities in different points on the sample. The aim of the present study was to determine in vitro the anisotropic elastic properties of cortical bones. For this purpose, our method allowed measurement of longitudinal and transverse velocities (C(L) and C(T)) in longitudinal (fiber direction) and the radial directions (orthogonal to the fiber direction) of compact bones. Young's modulus E and Poisson's ratio nu, were then deduced from the velocities measured considering the compact bone as transversely isotropic or orthotropic. The results are in line with those of other methods.  相似文献   

8.
A method is presented to find orthotropic elastic symmetries and constants directly from the elastic coefficients in the overall stiffness matrix of trabecular bone test specimens. Contrary to earlier developed techniques, this method does not require pure orthotropic behavior or additional fabric measurements. The method uses high-resolution computer reconstructions of trabecular bone specimens as input for large-scale FE-analyses to determine all the 21 elastic coefficients in the overall stiffness matrix of the specimen, using a direct mechanics approach. An optimization procedure is then used to find the coordinate transformation that yields the best orthotropic representation of this matrix. The method is illustrated here relative to two trabecular bone specimens. The techniques developed here can be used to obtain a complete characterization of the mechanical properties of trabecular architecture. With the development of in vivo reconstruction techniques, even in vivo measurements will be possible.  相似文献   

9.
High-resolution finite element models of trabecular bone can be used to study trabecular structure–function relationships, elasticity, multiaxial strength, and tissue remodelling in more detail than experiments. Beside effects of the model size, scan/analysis resolution, segmentation process, etc., the type of the applied boundary conditions (BCs) have a strong influence on the predicted elastic properties. Appropriate BCs have to be applied on hexahedral digital finite element models in order to obtain effective elastic properties. Homogeneous displacement BCs as proposed by Van Rietbergen et al. (J Biomech 29(12):1653–1657, 1996) lead to “apparent” rather than to “effective” elastic properties. This study provides some answers concerning such differences by comparing various BC types (uniform displacement, mixed BCs, periodic BCs), different volume element definitions (original and mirrored models), and several bone volume fractions (BVTV ranging from 6.5 to 37.6%). First, the mixed BCs formulated by Hazanov (Arch Appl Mech 68(6):385–394, 1998) are theoretically extended to shear loading of a porous media. Second, six human bone samples are analyzed, their orthotropic Young’s moduli, shear moduli, and Poisson’s ratios computed and compared. It is found that the proposed mixed BCs give exactly the same effective elastic properties as periodic BCs if a periodic and orthotropic micro-structured material is used and thus denoted as “periodicity compatible” mixed uniform BCs (PMUBCs). As bone samples were shown to be nearly orthotropic for volume element side lengths ≥5 mm the proposed mixed BCs turn out to be the best choice because they give again essentially the same overall elastic properties as periodic BCs. For bone samples of smaller dimensions ( < 5 mm) with a strong anisotropy (beyond orthotropy) uniform displacement BCs remain applicable but they can significantly overestimate the effective stiffness. In Memoriam, Prof. Christian Huet.  相似文献   

10.
The key parameters determining the elastic properties of an unidirectional mineralized bone fibril-array decomposed in two further hierarchical levels are investigated using mean field methods. Modeling of the elastic properties of mineralized micro- and nanostructures requires accurate information about the underlying topology and the constituents’ material properties. These input data are still afflicted by great uncertainties and their influence on computed elastic constants of a bone fibril-array remains unclear. In this work, mean field methods are applied to model mineralized fibrils, the extra-fibrillar matrix and the resulting fibril-array. The isotropic or transverse isotropic elastic constants of these constituents are computed as a function of degree of mineralization, mineral distribution between fibrils and extra-fibrillar matrix, collagen stiffness and fibril volume fraction. The linear sensitivity of the elastic constants was assessed at a default set of the above parameters. The strain ratios between the constituents as well as the axial and transverse indentation moduli of the fibril-array were calculated for comparison with experiments. Results indicate that the degree of mineralization and the collagen stiffness dominate fibril-array elasticity. Interestingly, the stiffness of the extra-fibrillar matrix has a strong influence on transverse and shear moduli of the fibril-array. The axial strain of the intra-fibrillar mineral platelets is 30–90% of the applied fibril strain, depending on mineralization and collagen stiffness. The fibril-to-fibril-array strain ratio is essentially ~1. This study provides an improved insight in the parameters, which govern the fibril-array stiffness of mineralized tissues such as bone.  相似文献   

11.
The high-frequency elastic properties of rat-tail tendon collagen have been investigated by means of Brillouin (inelastic) light scattering. Longitudinally and transversely polarised elastic waves of frequency about 1010 Hz have been observed propagating at various angles to the fibre axis of stretched, partially dried tendon. Assuming that the elastic properties of tendon are transversely isotropic, these measurements enable the five elastic constants for such a system to be determined. In particular the ratio of the Young's modulus for strain parallel to the axis to that for strain perpendicular to the axis (EE) is found to be 1.43 and the ratio of the shear modulus to E is 0.28. In wet collagen only the longitudinal branch has been observed and in this case the ratio EE increases to 1.82. The absolute value for E in dry collagen is 11.9 GN m?2 reducing to 5.1 GN m?2 in wet collagen. An interpretation of these results in terms of the expected vibrations of the collagen molecular assembly is given. Possible applications to the determination of the mechanical properties of collagen composite materials such as bone are discussed as well as some measurements on silk and α- and β-keratins, which are fibrous proteins of different molecular conformation to collagen.  相似文献   

12.
An alternative concept of the relationship between morphological and elastic properties of trabecular bone is presented and applied to human tissue from several anatomical locations using a digital approach. The three-dimensional morphology of trabecular bone was assessed with a microcomputed tomography system and the method of directed secants as well as the star volume procedure were used to compute mean intercept length (MIL) and average bone length (ABL) of 4 mm cubic specimens. Assuming isotropic elastic properties for the trabecular tissue, the general elastic tensors of the bone specimens were determined using the homogenization method and the closest orthotropic tensors were calculated with an optimization algorithm. The assumption of orthotropy for trabecular bone was found to improve with specimen size and hold within 6.1 percent for a 4 mm cube size. A strong global relationship (r2 = 0.95) was obtained between fabric and the orthotropic elastic tensor with a minimal set of five constants. Mean intercept length and average bone length provided an equivalent power of prediction. These results support the hypothesis that the elastic properties of human trabecular bone from an arbitrary anatomical location can be estimated from an approximation of the anisotropic morphology and a prior knowledge of tissue properties.  相似文献   

13.
Micromechanical estimates of the elastic constants for a single bone osteonal lamella and its substructures are reported. These estimates of elastic constants are accomplished at three distinct and organized hierarchical levels, that of a mineralized collagen fibril, a collagen fiber, and a single lamella. The smallest collagen structure is the collagen fibril whose diameter is the order of 20 nm. The next structural level is the collagen fiber with a diameter of the order of 80 nm. A lamella is a laminate structure, composed of multiple collagen fibers with embedded minerals and consists of several laminates. The thickness of one laminate in the lamella is approximately 130 nm. All collagen fibers in a laminate in the lamella are oriented in one direction. However, the laminates rotate relative to the adjacent laminates. In this work, all collagen fibers in a lamella are assumed to be aligned in the longitudinal direction. This kind of bone with all collagen fibers aligned in one direction is called a parallel fibered bone. The effective elastic constants for a parallel fibered bone are estimated by assuming periodic substructures. These results provide a database for estimating the anisotropic poroelastic constants of an osteon and also provide a database for building mathematical or computational models in bone micromechanics, such as bone damage mechanics and bone poroelasticity.  相似文献   

14.
The macroscopic mechanical properties of trabecular bone can be predicted by its architecture using theoretical relationships between the elastic and architectural properties. Microdamage caused by overloading or fatigue decreases the apparent elastic moduli of trabecular bone requiring these relationships to be modified to predict the damaged elastic properties. In the case of isotropic damage, the apparent level elastic properties could be determined by multiplying all of the elastic constants by a single scalar factor. If the damage is anisotropic, the elastic constants may change by differing factors and the material coordinate system could become misaligned with the fabric coordinate system. High-resolution finite element models were used to simulate damage overloading on seven trabecular bone specimens subjected to pure shear strain in two planes. Comparison of the apparent elastic moduli of the specimens before and after damage showed that the reduction of the elastic moduli was anisotropic. This suggests that the microdamage within the specimens was inhomogeneous. However, after damage the specimens exhibited nearly orthotropic material symmetry as they did before damage. Changes in the orientation of the orthotropic material coordinate system were also small and occurred primarily in the transverse plane. Thus, while damage in trabecular bone is anisotropic, the material coordinate system remains aligned with the fabric tensor.  相似文献   

15.
Yoo A  Jasiuk I 《Journal of biomechanics》2006,39(12):2241-2252
Trabecular bone is modeled as a cellular material with an idealized periodic structure made of open cubic cells, which is effectively orthotropic. We evaluate apparent couple-stress moduli of such a periodic material; apparent moduli refer to the moduli obtained using a domain smaller than a Representative Volume Element and they depend on boundary conditions. We conduct this analysis computationally (using ANSYS) by subjecting a unit cell of this periodic cellular material to either displacement or traction boundary conditions. Cell walls, representing bone tissue, and void space, representing bone marrow, are both modeled and they are assumed to be linear elastic. The applied loadings include a uniaxial extension (or uniaxial stress), a hydrostatic deformation (or hydrostatic stress) and a shear deformation (or shear stress) to evaluate the first stiffness (or compliance) tensor, and an applied curvature (or bending moment), a uniaxial twist (or torsion), and a triaxial twist (or triaxial torsion) to evaluate the second couple-stress stiffness (or compliance) tensor. Apparent couple-stress moduli are computed by equating the total strain energy stored in the unit cell with the energy of an equivalent homogeneous orthotropic couple-stress material for each applied loading. The moduli computed using displacement boundary conditions give upper bound, while those obtained using traction boundary conditions give lower bound on effective couple-stress moduli. These bounds are very wide due to a large mismatch in elastic moduli of bone tissue and bone marrow. These results are in agreement with our studies on composite materials with very stiff or very compliant inclusions.  相似文献   

16.
The technique of resonant ultrasound spectroscopy (RUS) was used to measure the second-order elastic constants of hydrated human dentin. Specimens were placed between two transducers, and the resonant frequencies of vibration were measured between 0.5 and 1.4 MHz. The elastic constants determined from the measured resonant frequencies in hydrated dentin exhibited slight hexagonal anisotropy, with the stiffest direction being perpendicular to the axis of the tubules (E11 = 25.1GPA) This hexagonal anisotropy was small (E33/E11 = 0.92), and almost disappeared when the specimens were dried. In addition, there was a pronounced anisotropy in the Poisson's ratio of wet dentin: v21 = 0.45; v31 = 0.29. With drying in air, this anisotropy vanished: v21 = v31 = 0.29. The isotropic Young's modulus of dried dentin was 28.1 GPa. RUS shows promise for determining the elastic constants in mineralized tissues.  相似文献   

17.
The anisotropic elastic constants of human cortical bone were predicted using a specimen-specific micromechanical model that accounted for structural parameters across multiple length scales. At the nano-scale, the elastic constants of the mineralized collagen fibril were estimated from measured volume fractions of the constituent phases, namely apatite crystals and Type I collagen. The elastic constants of the extracellular matrix (ECM) were predicted using the measured orientation distribution function (ODF) for the apatite crystals to average the contribution of misoriented mineralized collagen fibrils. Finally, the elastic constants of cortical bone tissue were determined by accounting for the measured volume fraction of Haversian porosity within the ECM. Model predictions using the measured apatite crystal ODF were not statistically different from experimental measurements for both the magnitude and anisotropy of elastic constants. In contrast, model predictions using common idealized assumptions of perfectly aligned or randomly oriented apatite crystals were significantly different from the experimental measurements. A sensitivity analysis indicated that the apatite crystal volume fraction and ODF were the most influential structural parameters affecting model predictions of the magnitude and anisotropy, respectively, of elastic constants.  相似文献   

18.
The six non-interacting modes for stress, strain and energy in an orthotropic elastic model of human femoral cortical bone tissue are discussed and illustrated. The stress and strain modes are illustrated using the representation of the stress and strain fields around a circular hole in a flat plate of cortical bone subjected to a uniaxial field of tension as the example. The six modes play a role in the stress analysis of orthotropic elastic materials similar to the roles played by the hydrostatic and deviatoric non-interacting stress, strain and energy modes in isotropic elasticity. The biomechanical significance of the six non-interacting modes for stress, strain and energy in hard tissue is both practical and suggestive. The modes suggest a practical scheme for the representation of stress and strain fields in hard tissue. The existence of the modes suggests physical insights, for example, possible failure mechanisms or adaptation strategies possessed by the hard tissues.  相似文献   

19.
Linear elastic theory has served well in modeling the mechanical properties of numerous materials. In modeling ultrasonic wave propagation in biological soft tissues, an isotropic model has usually been employed. Many tissues, however, possess a lower order of symmetry, and the speed of sound in muscle is known to vary with the direction of propagation. In this study, by applying linear regression to acoustic microscopic data from seven frog sartorius specimens, four observable elastic constants associated with a transversely isotropic model were obtained. The average values of these constants were c11 = 2.64, c13 = 3.39 and c33 = 4.40 Nm-2 for resting muscles and c11 = 2.65, c13 = 3.43 and c33 = 4.57 Nm-2 for muscles undergoing tetanic contraction, where '1' and '3' represent the transverse and longitudinal axes, respectively. In all cases, c44 was 0, indicating a minimal contribution from longitudinal shear. For all seven specimens, the model of transverse isotropy provided a better fit of the data than that of isotropy.  相似文献   

20.
The anisotropic poroelastic constants of an osteon are estimated by micromechanical analysis. Two extreme cases are examined, the drained and the undrained elastic constants. The drained elastic constants are the porous medium’s effective elastic constants when the fluid in the pores easily escapes and the pore fluid can sustain no pore pressure. The undrained elastic constants are the porous medium’s effective elastic constants when the medium is fully saturated with pore fluid and the fluid cannot escape. The drained and undrained elastic constants at the lacunar and canalicular porosity tissue levels are estimated by using an effective moduli model consisting of the periodic distribution of ellipsoidal cavities. These estimated anisotropic poroelastic constants provide a database for the development of an accurate anisotropic poroelastic model of an osteon.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号