首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.

Background

In literature, the effect of the inflow boundary condition was investigated by examining the impact of the waveform and the shape of the spatial profile of the inlet velocity on the cardiac hemodynamics. However, not much work has been reported on comparing the effect of the different combinations of the inlet/outlet boundary conditions on the quantification of the pressure field and flow distribution patterns in stenotic right coronary arteries.

Method

Non-Newtonian models were used to simulate blood flow in a patient-specific stenotic right coronary artery and investigate the influence of different boundary conditions on the phasic variation and the spatial distribution patterns of blood flow. The 3D geometry of a diseased artery segment was reconstructed from a series of IVUS slices. Five different combinations of the inlet and the outlet boundary conditions were tested and compared.

Results

The temporal distribution patterns and the magnitudes of the velocity, the wall shear stress (WSS), the pressure, the pressure drop (PD), and the spatial gradient of wall pressure (WPG) were different when boundary conditions were imposed using different pressure/velocity combinations at inlet/outlet. The maximum velocity magnitude in a cardiac cycle at the center of the inlet from models with imposed inlet pressure conditions was about 29% lower than that from models using fully developed inlet velocity data. Due to the fact that models with imposed pressure conditions led to blunt velocity profile, the maximum wall shear stress at inlet in a cardiac cycle from models with imposed inlet pressure conditions was about 29% higher than that from models with imposed inlet velocity boundary conditions. When the inlet boundary was imposed by a velocity waveform, the models with different outlet boundary conditions resulted in different temporal distribution patterns and magnitudes of the phasic variation of pressure. On the other hand, the type of different boundary conditions imposed at the inlet and the outlet did not have significant effect on the spatial distribution patterns of the PD, the WPG and the WSS on the lumen surface, regarding the locations of the maximum and the minimum of each quantity.

Conclusions

The observations from this study indicated that the ways how pressure and velocity boundary conditions are imposed in computational models have considerable impact on flow velocity and shear stress predictions. Accuracy of in vivo measurements of blood pressure and velocity is of great importance for reliable model predictions.
  相似文献   

2.

Background  

The aortic aneurysm is a dilatation of the aortic wall which occurs in the saccular and fusiform types. The aortic aneurysms can rupture, if left untreated. The renal stenosis occurs when the flow of blood from the arteries leading to the kidneys is constricted by atherosclerotic plaque. This narrowing may lead to the renal failure. Previous works have shown that, modelling is a useful tool for understanding of cardiovascular system functioning and pathophysiology of the system. The present study is concerned with the modelling of aortic aneurysms and renal artery stenosis using the cardiovascular electronic system.  相似文献   

3.

Background

Severe osteoarthritis and thoracic aortic aneurysms have recently been associated with mutations in the SMAD3 gene, but the full clinical spectrum is incompletely defined.

Methods

All SMAD3 gene mutation carriers coming to our centre and their families were investigated prospectively with a structured panel including standardized clinical workup, blood tests, total body computed tomography, joint X-rays. Electroneuromyography was performed in selected cases.

Results

Thirty-four SMAD3 gene mutation carriers coming to our centre were identified and 16 relatives were considered affected because of aortic surgery or sudden death (total 50 subjects). Aortic disease was present in 72%, complicated with aortic dissection, surgery or sudden death in 56% at a mean age of 45 years. Aneurysm or tortuosity of the neck arteries was present in 78%, other arteries were affected in 44%, including dissection of coronary artery. Overall, 95% of mutation carriers displayed either aortic or extra-aortic arterial disease. Acrocyanosis was also present in the majority of patients. Osteoarticular manifestations were recorded in all patients. Joint involvement could be severe requiring surgery in young patients, of unusual localization such as tarsus or shoulder, or mimicking crystalline arthropathy with fibrocartilage calcifications. Sixty eight percent of patients displayed neurological symptoms, and 9 suffered peripheral neuropathy. Electroneuromyography revealed an axonal motor and sensory neuropathy in 3 different families, very evocative of type II Charcot-Marie-Tooth (CMT2) disease, although none had mutations in the known CMT2 genes. Autoimmune features including Sjogren’s disease, rheumatoid arthritis, Hashimoto’s disease, or isolated autoantibodies- were found in 36% of patients.

Interpretation

SMAD3 gene mutations are associated with aortic dilatation and osteoarthritis, but also autoimmunity and peripheral neuropathy which mimics type II Charcot-Marie-Tooth.  相似文献   

4.

Background  

The success of stent implantation in the restoration of blood flow through areas of vascular narrowing is limited by restenosis. Several recent studies have suggested that the local geometric environment created by a deployed stent may influence regional blood flow characteristics and alter distributions of wall shear stress (WSS) after implantation, thereby rendering specific areas of the vessel wall more susceptible to neointimal hyperplasia and restenosis. Stents are most frequently implanted in curved vessels such as the coronary arteries, but most computational studies examining blood flow patterns through stented vessels conducted to date use linear, cylindrical geometric models. It appears highly probable that restenosis occurring after stent implantation in curved arteries also occurs as a consequence of changes in fluid dynamics that are established immediately after stent implantation.  相似文献   

5.

Background/Objectives

To evaluate the predictive value of CT-derived measurements of the aortic annulus for prosthesis sizing in transcatheter aortic valve implantation (TAVI) and to calculate optimal cutoff values for the selection of various prosthesis sizes.

Methods

The local IRB waived approval for this single-center retrospective analysis. Of 441 consecutive TAVI-patients, 90 were excluded (death within 30 days: 13; more than mild aortic regurgitation: 10; other reasons: 67). In the remaining 351 patients, the CoreValve (Medtronic) and the Edwards Sapien XT valve (Edwards Lifesciences) were implanted in 235 and 116 patients. Optimal prosthesis size was determined during TAVI by inflation of a balloon catheter at the aortic annulus. All patients had undergone CT-angiography of the heart or body trunk prior to TAVI. Using these datasets, the diameter of the long and short axis as well as the circumference and the area of the aortic annulus were measured. Multi-Class Receiver-Operator-Curve analyses were used to determine the predictive value of all variables and to define optimal cutoff-values.

Results

Differences between patients who underwent implantation of the small, medium or large prosthesis were significant for all except the large vs. medium CoreValve (all p’s<0.05). Furthermore, mean diameter, annulus area and circumference had equally high predictive value for prosthesis size for both manufacturers (multi-class AUC’s: 0.80, 0.88, 0.91, 0.88, 0.88, 0.89). Using the calculated optimal cutoff-values, prosthesis size is predicted correctly in 85% of cases.

Conclusion

CT-based aortic root measurements permit excellent prediction of the prosthesis size considered optimal during TAVI.  相似文献   

6.
Y Li  Z Shi  Y Cai  Y Feng  G Ma  C Shen  Z Li  N Liu 《PloS one》2012,7(8):e42558

Background

Coronary tortuosity (CT) is a common coronary angiographic finding. Whether CT leads to an apparent reduction in coronary pressure distal to the tortuous segment of the coronary artery is still unknown. The purpose of this study is to determine the impact of CT on coronary pressure distribution by numerical simulation.

Methods

21 idealized models were created to investigate the influence of coronary tortuosity angle (CTA) and coronary tortuosity number (CTN) on coronary pressure distribution. A 2D incompressible Newtonian flow was assumed and the computational simulation was performed using finite volume method. CTA of 30°, 60°, 90°, 120° and CTN of 0, 1, 2, 3, 4, 5 were discussed under both steady and pulsatile conditions, and the changes of outlet pressure and inlet velocity during the cardiac cycle were considered.

Results

Coronary pressure distribution was affected both by CTA and CTN. We found that the pressure drop between the start and the end of the CT segment decreased with CTA, and the length of the CT segment also declined with CTA. An increase in CTN resulted in an increase in the pressure drop.

Conclusions

Compared to no-CT, CT can results in more decrease of coronary blood pressure in dependence on the severity of tortuosity and severe CT may cause myocardial ischemia.  相似文献   

7.

Background

We have developed a rat cell model for studying collagen type I production in coronary artery adventitial fibroblasts. Increased deposition of adventitial collagen type I leads to stiffening of the blood vessel, increased blood pressure, arteriosclerosis and coronary heart disease. Although the source and mechanism of collagen deposition is yet unknown, the adventitia appears to play a significant role. To demonstrate the application of our cell model, cultured adventitial fibroblasts were treated with sex hormones and the effect on collagen production measured.

Methods

Hearts (10–12 weeks) were harvested and the left anterior descending coronary artery (LAD) was isolated and removed. Tissue explants were cultured and cells (passages 2–4) were confirmed as fibroblasts using immunohistochemistry. Optimal conditions were determined for cell tissue harvest, timing, proliferation and culture conditions. Fibroblasts were exposed to 10-7 M testosterone or 10-7 M estrogen for 24 hours and either immunostained for collagen type I or subjected to ELISA.

Results

Results showed increased collagen staining in fibroblasts treated with testosterone compared to control and decreased staining with estrogen. ELISA results showed that testosterone increased collagen I by 20% whereas estrogen decreased collagen I by 15%.

Conclusion

Data demonstrates the usefulness of our cell model in studying the specific role of the adventitia apart from other blood vessel tissue in rat coronary arteries. Results suggest opposite effects of testosterone and estrogen on collagen synthesis in the rat coronary artery adventitial fibroblasts.  相似文献   

8.
This case report describes a useful and unusual route for insertion of an intraaortic balloon in 63-year-old man who was operated upon for calcific aortic stenosis, coronary atherosclerosis involving the left anterior descending and right coronary arteries, and a large abdominal aortic aneurysm. Aortic valve replacement was accomplished with a porcine heterograft prosthesis. Bypasses to the left anterior descending and right coronary arteries were constructed with reversed saphenous vein grafts, and the abdominal aneurysm was resected and repaired with a bifurcated woven Dacron vascular graft. An electively placed intraaortic balloon was inserted through the right limb of the aortic graft prosthesis and used to assist the patient during the immediate postoperative period. Uneventful recovery ensued.  相似文献   

9.

Background

Circulating microparticles (MPs) derived from endothelial cells and blood cells bear procoagulant activity and promote thrombin generation. Thrombin exerts proinflammatory effects mediating the progression of atherosclerosis. Aortic valve stenosis may represent an atherosclerosis-like process involving both the aortic valve and the vascular system. The aim of this study was to investigate whether MP-induced thrombin generation is related to coronary atherosclerosis and aortic valve calcification.

Methods

In a cross-sectional study of 55 patients with severe aortic valve stenosis, we assessed the coronary calcification score (CAC) as indicator of total coronary atherosclerosis burden, and aortic valve calcification (AVC) by computed tomography. Thrombin-antithrombin complex (TATc) levels were measured as a marker for thrombin formation. Circulating MPs were characterized by flow cytometry according to the expression of established surface antigens and by measuring MP-induced thrombin generation.

Results

Patients with CAC score below the median were classified as patients with low CAC, patients with CAC Score above the median as high CAC. In patients with high CAC compared to patients with low CAC we detected higher levels of TATc, platelet-derived MPs (PMPs), endothelial-derived MPs (EMPs) and MP-induced thrombin generation. Increased level of PMPs and MP-induced thrombin generation were independent predictors for the severity of CAC. In contrast, AVC Score did not differ between patients with high and low CAC and did neither correlate with MPs levels nor with MP-induced thrombin generation.

Conclusion

In patients with severe aortic valve stenosis MP-induced thrombin generation was independently associated with the severity of CAC but not AVC indicating different pathomechanisms involved in coronary artery and aortic valve calcification.  相似文献   

10.

Background  

Many cardiovascular diseases, such as aortic dissection, frequently occur on the aortic arch and fluid-structure interactions play an important role in the cardiovascular system. Mechanical stress is crucial in the functioning of the cardiovascular system; therefore, stress analysis is a useful tool for understanding vascular pathophysiology. The present study is concerned with the stress distribution in a layered aortic arch model with interaction between pulsatile flow and the wall of the blood vessel.  相似文献   

11.

Objectives

To determine inter-session and intra/inter-individual variations of the attenuations of aortic blood/myocardium with MDCT in the context of calcium scoring. To evaluate whether these variations are dependent on patients’ characteristics.

Methods

Fifty-four volunteers were evaluated with calcium scoring non-enhanced CT. We measured attenuations (inter-individual variation) and standard deviations (SD, intra-individual variation) of the blood in the ascending aorta and of the myocardium of left ventricle. Every volunteer was examined twice to study the inter-session variation. The fat pad thickness at the sternum and noise (SD of air) were measured too. These values were correlated with the measured aortic/ventricular attenuations and their SDs (Pearson). Historically fixed thresholds (90 and 130 HU) were tested against different models based on attenuations of blood/ventricle.

Results

The mean attenuation was 46HU (range, 17-84HU) with mean SD 23HU for the blood, and 39HU (10-82HU) with mean SD 18 HU for the myocardium. The attenuation/SD of the blood were significantly higher than those of the myocardium (p<0.01). The inter-session variation was not significant. There was a poor correlation between SD of aortic blood/ventricle with fat thickness/noise. Based on existing models, 90 HU threshold offers a confidence interval of approximately 95% and 130 HU more than 99%.

Conclusions

Historical thresholds offer high confidence intervals for exclusion of aortic blood/myocardium and by the way for detecting calcifications. Nevertheless, considering the large variations of blood/myocardium CT values and the influence of patient’s characteristics, a better approach might be an adaptive threshold.  相似文献   

12.

Background  

Cell proliferation and apoptosis are both involved in arterial wall remodeling. Increase in blood flow induces arterial enlargement. The molecular basis of flow-induced remodeling in large elastic arteries is largely unknown.  相似文献   

13.

Background

Coronary blood flow can always be matched to the metabolic demand of the myocardium due to the regulation of vasoactive segments. Myocardial compressive forces play an important role in determining coronary blood flow but its impact on flow regulation is still unknown. The purpose of this study was to develop a coronary specified flow regulation model, which can integrate myocardial compressive forces and other identified regulation factors, to further investigate the coronary blood flow regulation behavior.

Method

A theoretical coronary flow regulation model including the myogenic, shear-dependent and metabolic responses was developed. Myocardial compressive forces were included in the modified wall tension model. Shear-dependent response was estimated by using the experimental data from coronary circulation. Capillary density and basal oxygen consumption were specified to corresponding to those in coronary circulation. Zero flow pressure was also modeled by using a simplified capillary model.

Result

Pressure-flow relations predicted by the proposed model are consistent with previous experimental data. The predicted diameter changes in small arteries are in good agreement with experiment observations in adenosine infusion and inhibition of NO synthesis conditions. Results demonstrate that the myocardial compressive forces acting on the vessel wall would extend the auto-regulatory range by decreasing the myogenic tone at the given perfusion pressure.

Conclusions

Myocardial compressive forces had great impact on coronary auto-regulation effect. The proposed model was proved to be consistent with experiment observations and can be employed to investigate the coronary blood flow regulation effect in physiological and pathophysiological conditions.  相似文献   

14.
Cao L  Zhang Y  Cao YX  Edvinsson L  Xu CB 《PloS one》2012,7(3):e33008

Background

Cigarette smoking is a strong cardiovascular risk factor and endothelin (ET) receptors are related to coronary artery diseases. The present study established an in vivo secondhand smoke (SHS) exposure model and investigated the hypothesis that cigarette smoke induces ET receptor upregulation in rat coronary arteries and its possible underlying mechanisms.

Methodology/Principal Findings

Rats were exposed to SHS for 200 min daily for 8 weeks. The coronary arteries were isolated and examined. The vasoconstriction was studied by a sensitive myograph. The expression of mRNA and protein for receptors was examined by real-time PCR, Western blot and immunofluorescence. Compared to fresh air exposure, SHS increased contractile responses mediated by endothelin type A (ETA) and type B (ETB) receptors in coronary arteries. In parallel, the expression of mRNA and protein for ETA and ETB receptors of smoke exposed rats were higher than that of animals exposed to fresh air, suggesting that SHS upregulates ETA and ETB receptors in coronary arteries in vivo. Immunofluorescence staining showed that the enhanced receptor expression was localized to the smooth muscle cells of coronary arteries. The protein levels of phosphorylated (p)-Raf-1 and p-ERK1/2 in smoke exposed rats were significantly higher than in control rats, demonstrating that SHS induces the activation of the Raf/ERK/MAPK pathway. Treatment with Raf-1 inhibitor GW5074 suppressed SHS-induced enhanced contraction mediated by ETA receptors, and inhibited the elevated mRNA and protein levels of ETA and ETB receptors caused by SHS. The results of correlation and regression analysis showed that phosphorylation of Raf and ERK1/2 were independent determinants to affect protein expression of ETB and ETA receptors.

Conclusions/Significance

Cigarette smoke upregulates ETB and ETA receptors in rat coronary artery, which is associated with the activation of the Raf/ERK/MAPK pathway.  相似文献   

15.

Background  

The first type III repeat of fibronectin is known to be involved in fibronectin matrix assembly, and recombinant proteins from this type III repeat can inhibit cell proliferation, tumor metastasis and angiogenesis. We have analyzed the way rat aortic smooth muscle cells (RASMCs) interact with a recombinant protein encompassing a C-terminal portion of the first type III repeat of fibronectin (protein III1-C).  相似文献   

16.

Background

Improvements in ultrasound technology has enabled direct, transthoracic visualization of long portions of coronary arteries : the left anterior descending (LAD), circumflex (Cx) and right coronary artery (RCA). Transthoracic measurements of coronary flow velocity were proved to be highly reproducible and correlated with invasive measurements. While clinical applications of transthoracic echocardiography (TTE) of principal coronary arteries are still very limited they will likely grow. The echocardiographers may therefore be interested to know the ultrasonic views, technique of examination and be aware where to look for coronary arteries and how to optimize the images.

Methods

A step-by-step approach to direct, transthoracic visualization of the LAD, Cx and RCA is presented. The technique of examination is discussed, correlations with basic coronary angiography views and heart anatomy are shown and extensively illustrated with photographs and movie-pictures. Hints concerning optimization of ultrasound images are presented and artifacts of imaging are discussed.

Conclusions

Direct, transthoracic examination of the LAD, Cx and RCA in adults is possible and may become a useful adjunct to other methods of coronary artery examination but studies are needed to establish its role.  相似文献   

17.

Background

An important number of patients with suspected cardiac chest pain have non-obstructive coronary artery disease. Our purpose was to describe the clinical characteristics of patients with normal or near-normal coronary arteries in routine cardiological practice in a secondary care hospital.

Methods

In 2013, consecutive patients referred for invasive coronary angiography with suspected cardiac chest pain were analysed at a single-centre (Westfriesgasthuis, Hoorn, the Netherlands). Coronary arteries were defined as normal or near-normal if they showed no stenosis or only slight wall irregularities on visual assessment. Patients with a final non-cardiac diagnosis for the chest pain were excluded.

Results

A total of 558 patients were included. Of these, 151 (27%) showed normal or near-normal coronary arteries on visual assessment. This group of patients were significantly more often female (p < 0.001), younger (p < 0.001) and non-diabetic (p = 0.002). Forty percent of hospitalised patients who had normal or near-normal coronary arteries at coronary angiography showed an elevated troponin.

Conclusion

In routine cardiological practice, around 1 out of 4 patients with suspected cardiac chest pain undergoing invasive angiography had normal or near-normal coronary arteries. We suggest that premenopausal women with suspected cardiac chest pain could be considered for non-invasive coronary imaging as a first step in clinical practice.
  相似文献   

18.

Background

In the era of primary percutaneous coronary intervention (PPCI), the incidence of post-cardiac injury syndrome (PCIS) in patients with acute myocardial infarction (AMI) following PPCI has become less common. However, the intrinsic pathogenesis of this medical condition remains largely uncertain. Unlike the prior reports, the present paper provides new mechanistic clues concerning the pathogenesis of PCI-related PCIS.

Case presentation

A 45-year-old male with AMI had developed an early onset of PCIS at 3?h after PPCI. A significantly slower TIMI flow (grade ≤?2) for the culprit arteries was observed through follow-up coronary angiography (CAG); no stent thrombosis or any significant evidence of iatrogenic trauma due the intervention procedures was found. Nevertheless, the the serum level of HsCRP showed similar variation trend as the neutrophil count and troponin T in continuous blood monitoring, which suggested a potential association between PPCI-related coronary microvascular dysfunction (CMD) and pathogenesis of PCIS.

Conclusions

The reported case had excessive inflammatory reaction and CMD resulting from cardiac ischemia-reperfusion injury in an AMI patient with risk factors of endothelial dysfunction. There exists a potential reciprocal causation between PCIS and performance of PPCI in the AMI patient who was susceptible to endothelial damage.
  相似文献   

19.
Ronald J. Baird  Irving H. Lipton 《CMAJ》1965,92(21):1099-1105
The changes and improvements in the surgical treatment of aortic valve disease in 296 patients, who were operated on between 1953 and 1965, are illustrated and discussed in general terms. Several of the early techniques, such as transventricular dilation, insertion of a homograft aortic valve in the descending thoracic aorta, fabric replacement of one cusp or the entire valve, and ice-chip arrest of the heart, are now obsolete. Total replacement with a ball-valve prosthesis or an aortic valve homograft while the coronary arteries are perfused with blood is the currently popular technique. The results of a hemodynamic follow-up study two years after surgery are also included.  相似文献   

20.

Background

Adverse events from Melody valve implantation may be catastrophic. To date a role for three dimensional rotational angiography of the aortic root (3DRAA) during Melody valve implantation has not been established.

Objectives

To describe the role of 3DRAA in the assessment of Melody valve candidacy and to demonstrate that it may improve outcomes.

Methods

All patients who underwent cardiac catheterisation for Melody valve implantation and 3DRAA between August 2013 and February 2015 were reviewed.

Results

31 patients had 3DRAA with balloon sizing. Ten were deemed not Melody candidates (5 coronary compression, 2 aortic root distortion with cusp flattening, 2 RVOT was too large, and 1 had complex branch stenosis and a short landing zone). Of the 21 patients who were Melody candidates, 12 had conduits, 6 prosthetic valves and 3 native RVOTs. In patients with conduits, the technique of stenting the conduit prior to dilation was used after measuring the distance between the conduit and the coronary arteries on 3DRAA. In the Melody patients, we had 100% procedural success and no serious adverse events (coronary compression, tears, stent fracture or endocarditis).

Conclusion

As a tool for case selection, 3DRAA may facilitate higher procedural success and decreased risk of serious adverse events. Furthermore, 3D rotational angiography allows stenting of the conduit prior to dilation, which may prevent tears and possibly endocarditis.
  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号