首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
A selective, rapid and sensitive ultra-performance liquid chromatography/tandem mass spectrometry (UPLC/MS/MS) method was developed for the quantitative determination of mitiglinide in human plasma. With nateglinide as internal standard, sample pretreatment involved a one-step extraction with diethyl ether of 0.2 mL plasma. The separation was performed on an ACQUITY UPLCtrade mark BEH C(18) column (50 mm x 2.1 mm, i.d., 1.7 microm) with the mobile phase consisting of methanol and 10 mmol/L ammonium acetate (65:35, v/v) at a flow rate of 0.25 mL/min. The detection was carried out by means of electrospray ionization mass spectrometry in positive ion mode with multiple reaction monitoring (MRM). Linear calibration curves were obtained in the concentration range of 1.080-5400 ng/mL, with a lower limit of quantification of 1.080 ng/mL. The intra- and inter-day precision (RSD) values were below 15% and accuracy (RE) was from -3.5% to 7.3% at all QC levels. The method was fully validated and successfully applied to a clinical pharmacokinetic study of mitiglinide in 10 healthy volunteers following oral administration.  相似文献   

2.
A sample treatment procedure and high-sensitive liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) method for quantitative determination of fexofenadine in human plasma was developed for a microdose clinical trial with a cold drug, i.e., a non-radioisotope-labeled drug. Fexofenadine and terfenadine, as internal standard, were extracted from plasma samples using a 96-well solid-phase extraction plate (Oasis HLB). Quantitation was performed on an ACQUITY UPLC system and an API 5000 mass spectrometer by multiple reaction monitoring. Chromatographic separation was achieved on an XBridge C18 column (100 mm x 2.1 mm i.d., particle size 3.5 microm) using acetonitrile/2 mM ammonium acetate (91:9, v/v) as the mobile phase at a flow rate of 0.6 ml/min. The analytical method was validated in accordance with the FDA guideline for validation of bioanalytical methods. The calibration curve was linear in the range of 10-1000 pg/ml using 200 microl of plasma. Analytical method validation for the clinical dose, for which the calibration curve was linear in the range of 1-500 ng/ml using 20 microl of plasma, was also conducted. Each method was successfully applied for making determinations in plasma using LC/ESI-MS/MS after administration of a microdose (100 microg solution) and a clinical dose (60 mg dose) in eight healthy volunteers.  相似文献   

3.
Ursolic acid is a hydroxy pentacyclic triterpene, which proved to have sedation, anti-inflammatory, antibacterial, antiulcer and anti-cancer activities. An ultra-performance liquid chromatography/tandem mass spectrometry (UPLC/MS/MS) method with high selectivity, sensitivity and throughput has been established and validated for quantitation of total ursolic acid in human plasma. Plasma samples were pretreated by liquid-liquid extraction with ethyl acetate and were chromatographed by an ACQUITY UPLC BEH C(8) column (100 mm×2.1 mm, I.D., 1.7 μm) using mobile phase consisting of acetonitrile and 10 mM ammonium formate (90:10, v/v) at 0.2 mL/min. The duration of chromatography analysis was 3 min. The multiple reaction monitoring (MRM) was performed at m/z 455.1→455.0 for ursolic acid and m/z 469.3→425.2 for glycyrrhetinic acid (internal standard, IS) in the negative ion mode with electrospray ionization (ESI) source. The assay showed good linearity over the range of 10-5000 ng/mL for ursolic acid in human plasma with a lower limit of quantitation of 10 ng/mL. The mean extraction recovery was 73.2±4.5% and the matrix ion suppression ranged from -11.4% to -5.6%. The intra- and inter-day precisions were less than 7.0% and 7.2%, respectively, and the accuracy was within ±2.0%. Ursolic acid was stable during the analysis and the storage period. The validated method has been successfully applied to a pharmacokinetic study after intravenous infusion of Ursolic Acid Nano-liposomes to healthy volunteers.  相似文献   

4.
A selective, rapid and sensitive ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was developed for the quantitative determination of azithromycin in human plasma and its application in a pharmacokinetic study. With roxithromycin as internal standard, sample pretreatment involved a one-step extraction with diethyl ether of 0.5 mL plasma. The analysis was carried out on an ACQUITY UPLC BEH C(18) column (50 mm x 2.1 mm, i.d., 1.7 microm) with gradient elution at flow rate of 0.35 mL/min. The mobile phase was 50 mM ammonium acetate and acetonitrile. The detection was performed on a triple-quadrupole tandem mass spectrometer by multiple reaction monitoring (MRM) mode via electrospray ionization (ESI). Linear calibration curves were obtained in the concentration range of 1-1000 ng/mL, with a lower limit of quantification of 1 ng/mL. The intra- and inter-day precision (RSD) values were below 15% and accuracy (RE) was -1.3% to 5.7% at all QC levels. The method was applicable to clinical pharmacokinetic study of azithromycin in healthy volunteers following oral administration.  相似文献   

5.
High-performance liquid chromatography, coupled to tandem mass spectrometry (HPLC–MS/MS) has been established as the method of choice for the sensitive and simultaneous determination of different folates in a particular matrix, especially when only minute quantities of material are available. Using a previously developed and validated HPLC–MS/MS method as a starting point, we here report on the development and validation of an ultra-performance liquid chromatography (UPLC–MS/MS) method for analysis of folates in rice, which allows higher throughput and better resolution. UPLC was performed under gradient conditions on an Acquity HSS T3 column, followed by tandem mass spectrometry detection. The method was validated based on linearity, sensitivity, precision, accuracy and matrix effects. The limits of detection and the lower limits of quantification varied between 0.06 and 0.45 μg/100 g and 0.12 and 0.91 μg/100 g, respectively. Two linear calibration curves were established, one for the low and the other for the high concentration range. Analysis of the distribution and levels of folates in wild-type and folate-biofortified rice showed up to 50-fold enrichment in biofortified rice, with total folate levels of up to 900 μg/100 g rice. This is the first successful implementation of a UPLC method for the rapid and sensitive quantitative determination of folates in plant material.  相似文献   

6.
A sensitive liquid chromatography/tandem mass spectrometric (LC-MS/MS) method was developed and validated for the determination of rosuvastatin in human plasma. The plasma samples were prepared using liquid-liquid extraction with ethyl ether. Chromatographic separation was accomplished on a Zorbax XDB-C18 (150 mm x 4.6 mm i.d., 5 microm) column. The mobile phase consisted of methanol-water (75:25, v/v, adjusted to pH 6 by aqueous ammonia). Detection of rosuvastatin and the internal standard (IS) hydrochlorothiazide was achieved by ESI MS/MS in the negative ion mode. The lower limit of quantification was 0.020 ng/ml by using 200 microl aliquots of plasma. The linear range of the method was from 0.020 to 60.0 ng/ml. The intra- and inter-day precisions were lower than 8.5% in terms of relative standard deviation (RSD), and the accuracy was within -0.3 to 1.9% in terms of relative error (RE). Compared with the existing methods, the validated method offered increased sensitivity. The method was successfully applied for the evaluation of pharmacokinetics of rosuvastatin after single oral doses of 5, 10 and 20 mg rosuvastatin to 10 healthy volunteers.  相似文献   

7.
A novel generic ultra performance liquid chromatography-tandem mass spectrometric (UPLC/MS/MS) method for the high throughput quantification of samples generated during permeability assessment (PAMPA) has been developed and validated. The novel UPLC/MS/MS methodology consists of two stages. Firstly, running a 1.5min isocratic method, compound-specific multiple reaction monitoring (MRM) methods were automatically prepared. In a second stage, samples were analyzed by a 1.5min generic gradient UPLC method on a BEH C18 column (50mmx2.1mm). Compounds were detected with a Waters Micromass Quattro Premier mass spectrometer operating in positive electrospray ionization using the compound-specific MRM methods. The linearity for the validation compounds (caffeine, propranolol, ampicillin, atenolol, griseofulvin and carbamazepine) typically ranges from 3.05nM to 12,500nM and the limits of detection for all generically developed methods are in the range between 0.61nM and 12nM in an aqueous buffer. The novel generic methodology was successfully introduced within early Drug Discovery and resulted in a four-fold increase of throughput as well as a significant increase in sensitivity compared to other in-house generic LC/MS methods.  相似文献   

8.
A sensitive and selective high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method was developed for the determination of buagafuran in human plasma. The analyte was extracted from plasma samples with hexane after addition of isotopic internal standard and chromatographed on a RP-C(8) column. The mobile phase consisted of methanol-water (90:10, v/v) and the flow rate was 0.2 mL/min. The detection was performed on a triple quadrupole tandem mass spectrometer in multiple reactions monitoring (MRM) mode using positive electrospray ionization (ESI). The method was validated over the concentration range of 0.5-200 ng/mL. Inter- and intra-day precision (RSD%) were all within 15% and the accuracy (RE%) was equal or lower than 9.5%. The lower limit of quantitation (LLOQ) was 0.5 ng/mL. The extraction recovery was on average 38.1% and the detection was not affected by the matrix. The method was successfully applied to the pharmacokinetic study of buagafuran in healthy Chinese volunteers.  相似文献   

9.
A specific LC-MS/MS assay was developed for the automated determination of talinolol in human plasma, using on-line solid phase extraction system (prospekt 2) combined with atmospheric pressure chemical ionization (APCI) tandem mass spectrometry. The method involved simple precipitation of plasma proteins with perchloric acid (contained propranolol) as the internal standard (IS) and injection of the supernatant onto a C8 End Capped (10 mmx2 mm) cartridge without any evaporation step. Using the back-flush mode, the analytes were transferred onto an analytical column (XTerra C18, 50 mmx4.6 mm) for chromatographic separation and mass spectrometry detection. One of the particularities of the assay is that the SPE cartridge is used as a column switching device and not as an SPE cartridge. Therefore, the same SPE cartridge could be used more than 28 times, significantly reducing the analysis cost. APCI ionization was selected to overcome any potential matrix suppression effects because the analyte and IS co-eluted. The mean precision and accuracy in the concentration range 2.5-200 ng/mL was found to be 103% and 7.4%, respectively. The data was assessed from QC samples during the validation phase of the assay. The lower limit of quantification was 2.5 ng/mL, using a 250 microL plasma aliquot. The LC-MS/MS method provided the requisite selectivity, sensitivity, robustness accuracy and precision to assess pharmacokinetics of the compound in several hundred human plasma samples.  相似文献   

10.
A rapid, sensitive and selective ultra-performance liquid chromatography–tandem mass spectrometry (UPLC–MS/MS) method with hydrophilic interaction chromatography has been developed and validated for the simultaneous determination of didanosine and valdidanosine (L-valine amino acid ester prodrug of didanosine) in rat plasma. Solid-phase extraction (SPE) column was employed to extract the analytes from rat plasma, with high extraction recovery (>85%) for both didanosine and valdidanosine. The analytes were then separated by hydrophilic interaction chromatography (HILIC column) and detected by a triple-quadrupole mass spectrometry equipped with an electrospray ionization (ESI) source. The method was linear over the concentration ranges of 2–20,000 ng/mL for didanosine and 4–300 ng/mL for valdidanosine. The lower limit of quantitation (LLOQ) of didanosine and valdidanosine was 2 and 4 ng/mL, respectively. The intra-day and inter-day relative standard deviation (RSD) were less than 15% and the relative errors (RE) were all within 15%. Finally, the validated UPLC–MS/MS method was successfully applied to the pharmacokinetic study after either didanosine or valdidanosine orally administrated to the Sprague–Dawley rats.  相似文献   

11.
A rapid and specific ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS) method was developed for the qualitative and quantitative determination of UGT2B7 activity using 3'-azido-3'-deoxythymidine (AZT) as probe substrate in human liver microsomes (HLMs). The method was validated for the determination of AZT glucuronidation (AZTG) with respect to specificity, linearity, detection limit, recovery, stability, precision and accuracy. The chromatographic separation was achieved on a UPLC BEH C18 column (50 mm x 2.1mm i.d., 1.7 microm), with phase of acetonitrile-water (ratio 6:94). Selective ion reaction (SIR) monitor was specific for AZT, AZTG and I.S. The method was linear over the concentration range 0.5-500 microM for AZTG in spiked HLMs. Good precision and accuracy were obtained for concentrations over the standard curve range. AZTG was stable at 4 degrees C for at least 72 h in spiked liver microsomes samples. The method was successfully used to determine the kinetics of UGT activities toward AZT in HLMs. In addition, the method could determine the effects of fluconazole, a known UGT2B7 selective inhibitor, on AZTG in HLMs. Therefore, this method is suitable for in vitro studies using AZTG formation as an index reaction for UGT2B7 activity.  相似文献   

12.
The antimalarial drug amodiaquine is extensively metabolized to N-desethylamodiaquine (DEAQ) by cytochrome P450 2C8 (CYP2C8). DEAQ formation is an enzyme specific reaction that is used to quantify in vitro CYP2C8 activity. A rapid and sensitive method for the determination of DEAQ in human liver microsomes was developed using hydrophilic interaction liquid chromatography/tandem mass spectrometry (HILIC-MS/MS). Microsomal incubation samples were processed by protein precipitation with acetonitrile. The analytes were separated on a BETASIL Silica-100 (50mmx2.1mm, 5microm) column by isocratic elution at a flow rate of 220microl/min with a mobile phase consisting of 85% acetonitrile containing 5mM ammonium acetate and 0.1% formic acid. Detection was by positive electrospray ionization on a TSQ Quantum Discovery triple quadrupole mass spectrometer operated in the selective reaction monitoring mode. The precursor-product ion pair was m/z 328-->283 for DEAQ and m/z 331-->283 for DEAQ-d(3). The lower limit of quantification was 10nM for DEAQ and linearity was observed over the concentration range of 10-1500nM. Intra- and inter-day accuracy and precision were within 3.4 and 7.0%, respectively. The method was successfully applied to CYP2C8 drug metabolism studies in pooled human liver microsomes.  相似文献   

13.
A sensitive method for the determination of stavudine in plasma was developed, using high-performance liquid chromatographic separation with tandem mass spectrometric detection. The samples were extracted from plasma with Waters, Sep-Pak Vac, 100 mg, tC(18) solid-phase extraction (SPE) columns. Chromatography was performed on a Supelco Discovery C(18), 5 microm, 150 x 2 mm column with a mobile phase consisting of ammonium acetate (0.01 M)-acetonitrile-methanol (800:100:100, v/v/v) at a flow-rate of 0.3 ml/min. Detection was achieved by an Applied Biosystems API 2000 mass spectrometer (LC-MS-MS) set at unit resolution in the multiple reaction monitoring mode (MRM). Atmospheric pressure chemical ionization (APCI) was used for ion production. The mean recovery for stavudine was 94% with a lower limit of quantification set at 4 ng/ml. This assay method makes use of the increased sensitivity and selectivity of mass spectrometric (MS-MS) detection to allow for a more rapid (extraction and chromatography) and selective method for the determination of stavudine in human plasma than has previously been described.  相似文献   

14.
An analytical method based on liquid chromatography with positive ion electrospray ionization (ESI) coupled to tandem mass spectrometry detection was developed for the determination of lansoprazole in human plasma using omeprazole as the internal standard. The analyte and internal standard were extracted from the plasma samples by liquid-liquid extraction using diethyl-ether-dichloromethane (70:30; v/v) and chromatographed on a C(18) analytical column. The mobile phase consisted of acetonitrile-water (90:10; v/v)+10 mM formic acid. The method has a chromatographic total run time of 5 min and was linear within the range 2.5-2000 ng/ml. Detection was carried out on a Micromass triple quadrupole tandem mass spectrometer by Multiple Reaction Monitoring (MRM). The intra- and inter-run precision, calculated from quality control (QC) samples, was less than 3.4%. The accuracy as determined from QC samples was less than 9%. The method herein described was employed in a bioequivalence study of two capsule formulations of lansoprazole.  相似文献   

15.
Gemcitabine-squalene is a new prodrug that self-organizes in water forming nanoassemblies. It exhibits better anti-cancer properties in vitro and in vivo than gemcitabine. A liquid chromatography/tandem mass spectrometry assay of gemcitabine-squalene and gemcitabine was developed in human plasma in order to quantitate gemcitabine and its squalene conjugate. After protein precipitation with acetonitrile/methanol (90/10, v/v), the compounds were analyzed by reversed-phase high performance liquid chromatography and detected by tandem mass spectrometry using multiple reaction monitoring. The method was linear over the concentration range of 10-10,000 ng/ml of human plasma for both compounds with an accuracy lower than 10.4% and a precision below 14.8%. The method showed a lower limit of quantitation of 10 ng/ml of human plasma for dFdC and dFdC-SQ. A preliminary in vivo study in mice was shown as application of the method as no significant difference between human and mice plasma for the analysis of dFdC and dFdC-SQ was demonstrated.  相似文献   

16.
A rapid, sensitive, and environmental-friendly method has been developed for the simultaneous determination of seven neonicotinoid insecticides residues in bovine muscle and liver. The sample preparation procedure was based on a high automated pressurized solvent extraction (PSE) combined with solid-phase extraction (SPE) clean-up. The target compounds were identified and quantitatively determined by liquid chromatography coupled with electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) operated in multiple reaction monitoring mode. Average recoveries of the seven analytes from fortified samples ranged between 83.2% and 101.9%, with relative standard deviations (RSDs) lower than 10.8%. The limits of detection (LODs) and quantification (LOQs) for neonicotinoids were in the ranges of 0.8-1.5 μgkg?1 and 2.5-5.0 μgkg?1, respectively. This validated method was successively applied to the determination of neonicotinoid insecticides in real samples from markets.  相似文献   

17.
A simple, high throughput, direct-injection high-performance liquid chromatography tandem mass spectrometry method (LC/MS/MS) has been developed and validated for the quantitation of pioglitazone in human serum. After mixing the internal standard with a sample, a 10 microl portion of the mixture was directly injected into a high-flow LC/MS/MS system, which included an extraction column, an analytical column and a six-port switching valve. The on-line extraction was achieved on an Oasis HLB column (1 mm x 50 mm, 30 microm) with a 100% aqueous loading mobile phase containing 5 mM ammonium acetate (pH 4.0) at a flow rate of 4 ml/min. The extracted analyte was eluted by a mobile phase which contained 5 mM ammonium acetate and acetonitrile. The analytical column was a Luna C18 column (4.6 mm x 50 mm, 5 microm). Detection was achieved by positive ion electrospray tandem mass spectrometry. The lower limit of quantitation of the method was 9 ng/ml. The standard curve, which ranged from 9 to 1350 ng/ml, was fitted by a weighted (1/x2) quadratic regression model. The validation results demonstrated that this method had satisfactory precision and accuracy across the calibration range. There was no evidence of instability of the analyte in human serum following three freeze-thaw cycles, and samples could be stored for at least 2 weeks at -30 degrees C. This method was used to analyze pioglitazone concentrations in human serum samples from a bioequivalence study of a blinded Actos formulation (encapsulated 15 mg tablet) and an Actos 15 mg tablet. The blinded formulation was shown to be bioequivalent to an Actos 15 mg tablet.  相似文献   

18.
An analytical method based on liquid chromatography with positive ion electrospray ionization (ESI) coupled to tandem mass spectrometry detection (LC-MS/MS) was developed for the determination of a potent 5-HT(1B/1D) receptor agonist, rizatriptan in human plasma using granisetron as the internal standard. The analyte and internal standard were isolated from 100 microL plasma samples by liquid-liquid extraction (LLE) and chromatographed on a Lichrospher C18 column (4.6mm x 50mm, 5 microm) with a mobile phase consisting of acetonitrile-10mM aqueous ammonium acetate-acetic acid (50:50:0.5, v/v/v) pumped at 1.0 mL/min. The method had a chromatographic total run time of 2 min. A Varian 1200 L electrospray tandem mass spectrometer equipped with an electrospray ionization source was operated in selected reaction monitoring (SRM) mode with the precursor-to-product ion transitions m/z 270-->201 (rizatriptan) and 313.4-->138 (granisetron) used for quantitation. The assay was validated over the concentration range of 0.05-50 ng/mL and was found to have acceptable accuracy, precision, linearity, and selectivity. The mean extraction recovery from spiked plasma samples was above 98%. The intra-day accuracy of the assay was within 12% of nominal and intra-day precision was better than 13% C.V. Following a 10mg dose of the compound administered to human subjects, mean concentrations of rizatriptan ranged from 0.2 to 70.6 ng/mL in plasma samples collected up to 24h after dosing. Inter-day accuracy and precision results for quality control samples run over a 5-day period alongside clinical samples showed mean accuracies of within 12% of nominal and precision better than 9.5% C.V.  相似文献   

19.
A fast, sensitive and selective ultra performance liquid chromatography-tandem mass spectrometric (UPLC-MS/MS) method was developed for the determination of nifedipine in human plasma. Nitrendipine was used as the internal standard. The sample preparation employed liquid-liquid extraction with a mixture of n-hexane-diethyl ether (1:3, v/v). Chromatographic separation was performed on an ACQUITY UPLC? BEH C(18) column. The mobile phase was composed of acetonitrile-10 mmol/L ammonium acetate (75:25, v/v) with a flow rate of 0.20 mL/min. The detection was performed on a triple quadrupole tandem mass spectrometer by multiple reaction monitoring (MRM) mode via electrospray ionization (ESI) source. A high throughput was achieved with a run time of 1.4 min per sample. The linear calibration curves were obtained in the concentration range of 0.104-52.0 ng/mL (r(2)≥ 0.99) with a lower limit of quantification (LLOQ) of 0.104 ng/mL. The intra- and inter-day precision (relative standard deviation, RSD) values were below 15% and the accuracy (relative error, RE) was -4.0% to 6.2% at three quality control levels. The method was fully validated and successfully applied to a clinical pharmacokinetic study of nifedipine sustained-release tablet in healthy male volunteers.  相似文献   

20.
A simple and sensitive analytical method was developed for the simultaneous determination of clenbuterol, chloramphenicol and diethylstilbestrol in bovine milk by isotope dilution ultra performance liquid chromatography tandem mass spectrometry (UPLC–MS/MS). Samples were directly purified through HLB cartridge. The organic phase was dried under nitrogen and residues were redissolved in mobile phase. Samples were analyzed by UPLC–MS/MS on an Acquity UPLC® BEH C18 column with gradient elution. The samples were quantified using clenbuterol-D9, chloramphenicol-D5 and diethylstilbestrol-D8 as internal standards. The proposed method was validated according to the European Union regulation 2002/657/EC determining specificity, decision limit (CCα), detection capability (CCβ), trueness, precision, linearity and stability. The method is demonstrated to be suitable for the determination of clenbuterol, chloramphenicol and diethylstilbestrol in bovine milk. The total time required for the analysis of one sample was about 50 min.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号