首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
2.
3.
4.
In isovolumic blood-perfused dog hearts, left ventricular developed pressure (DP) was recorded while a sudden ventricular dilation was promoted at three heart rate (HR) levels: low (L: 52 +/- 1.7 beats/min), intermediate (M: 82 +/- 2.2 beats/min), and high (H: 117 +/- 3.5 beats/min). DP increased instantaneously with chamber expansion (Delta(1)DP), and another continuous increase occurred for several minutes (Delta(2)DP). HR elevation did not alter Delta(1)DP (32.8 +/- 1.6, 33.6 +/- 1.5, and 34.3 +/- 1.2 mmHg for L, M, and H, respectively), even though it intensified Delta(2)DP (17.3 +/- 0.9, 20.7 +/- 1.0, and 26.8 +/- 1.2 mmHg for L, M, and H, respectively), meaning that the treppe phenomenon enhances the length dependence of the contraction component related to changes in intracellular Ca(2+) concentration. Frequency increments reduced the half time of the slow response (82 +/- 3.6, 67 +/- 2.6, and 53 +/- 2.0 s for L, M, and H, respectively), while the number of beats included in half time increased (72 +/- 2.9, 95 +/- 2.9, and 111 +/- 3.2 beats for L, M, and H, respectively). HR modulation of the slow response suggests that L-type Ca(2+) channel currents and/or the Na(+)/Ca(2+) exchanger plays a relevant role in the stretch-triggered Ca(2+) gain when HR increases in the canine heart.  相似文献   

5.
6.
Developmental changes in left and right ventricular diastolic filling patterns were determined noninvasively in isoflurane-anesthetized outbred ICR mice. Blood velocities in the mitral and tricuspid orifices were recorded in 16 embryos at days 14.5 (E14.5) and 17.5 of gestation (E17.5) using an ultrasound biomicroscope and also serially in three groups of postnatal mice aged 1-7 days (n = 23), 1-4 wk (n = 18), and 4-12 wk (n = 27) using 20-MHz pulsed Doppler. Postnatal body weight increased rapidly to 8 wk. Heart rate increased rapidly from approximately 180 beats/min at E14.5 to approximately 380 beats/min at 1 wk after birth and then more gradually to plateau at approximately 450 beats/min after 4 wk. Ventricular filling was quantified using the ratio of peak velocity of early ventricular filling due to active relaxation (E wave) to that of the late ventricular filling caused by atrial contraction (A wave) (peak E/A ratio) and the ratio of the peak E velocity to total time-velocity integral of E and A waves (peak E/total TVI ratio). Both ventricles had similar diastolic filling patterns in embryos (peak E/A ratio of 0.28 +/- 0.02 for mitral flow and 0.27 +/- 0.02 for tricuspid flow at E14.5). After birth, mitral peak E/A increased to >1 between the third and fifth day, continued to increase to 2.25 +/- 0.25 at approximately 3 wk, and then remained stable. The tricuspid peak E/A ratio increased much less but stabilized at the same age (increased to 0.79 +/- 0.03 at 3 wk). The peak E/total TVI ratio showed similar left-right differences and changes with development. Age-related changes were largely due to increases in peak E velocity. The results suggest that diastolic function matures approximately 3 wk postnatally, presumably in association with maturation of ventricular recoil and relaxation mechanisms.  相似文献   

7.
8.

Background

Percutaneous left atrial appendage (LAA) closure can be an alternative to coumadin treatment in patients with atrial fibrillation (AF) at high risk for thromboembolic events and/or bleeding complications. We report the initial experience with this new technique.

Methods

Patients were eligible if they had AF with a high stroke risk (CHADS2 score >1), and/or contraindication for coumadin therapy. The procedure was performed under general anaesthesia, using biplane fluoroscopy and (3D) transoesophageal echocardiography (TEE) guidance. Patients were discharged on coumadin until a TEE was repeated at 45 days after closure to evaluate LAA occlusion. If LAA occlusion was achieved, oral anticoagulation was discontinued and aspirin started.

Results

Percutaneous LAA closure was performed in 10 patients (50% male, age 61.6 ± 9.6 years). The median CHADS2 score was 3 (range 2–4), median CHA2DS2-VASc score 3.5 (range 2–6) and HAS-BLED score 1.5 (range 1–4). Nine patients had a history of stroke and 2 patients had a history of major bleeding while on coumadin. Concomitant pulmonary vein isolation was performed in 9 patients. The device was successfully placed in all patients within a median of 56 min (38–137 min). Asymptomatic catheter thrombus occurred in one patient. At 45-day follow-up, no thromboembolic events occurred, TEE showed minimal residual flow in the LAA in three patients. In one patient the LAA device was dislocated, requiring successful percutaneous retrieval.

Conclusion

Device closure of the LAA may provide an alternative strategy to chronic coumadin therapy in patients with AF and high risk of stroke and/or bleeding complications using coumadin.  相似文献   

9.
OBJECTIVE: We investigated the effects of acute volume and RV pressure overload on biventricular function and gene expression of BNP, pro-inflammatory cytokines (IL-6 and TNF-alpha), iNOS, growth factors (IGF-1, ppET-1), ACE and Ca2+-handling proteins (SERCA2a, phospholamban and calsequestrin). METHODS: Male Wistar rats (n=45) instrumented with pressure tip micromanometers in right (RV) and left ventricular (LV) cavities were assigned to one of three protocols: i) Acute RV pressure overload induced by pulmonary trunk banding in order to double RV peak systolic pressure, during 120 or 360 min; ii) acute volume overload induced by dextran40 infusion (5 ml/h), during 120 or 360 min; iii) Sham. RV and LV samples were collected for mRNA quantification. RESULTS: BNP upregulation was restricted to the overloaded ventricles. TNF-alpha, IL-6, ppET-1, SERCA2a and phospholamban gene activation was higher in volume than in pressure overload. IGF-1 overexpression was similar in both types of overload, but was limited to the RV. TNF-alpha and CSQ mRNA levels were increased in the non-overloaded LV after pulmonary trunk banding. No significant changes were detected in ACE or iNOS expression. RV end-diastolic pressures positively correlated with local expression of BNP, TNF-alpha, IL-6, IGF-1, ppET-1 and SERCA2a, while RV peak systolic pressures correlated only with local expression of IL-6, IGF-1 and ppET-1. CONCLUSIONS: Acute cardiac overload alters myocardial gene expression profile, distinctly in volume and pressure overload. These changes correlate more closely with diastolic than with systolic load. Nonetheless, gene activation is also present in the non-overloaded LV of selectively RV overloaded hearts.  相似文献   

10.
11.
12.
13.
14.
Arrhythmogenic right ventricular dysplasia (ARVD) is a cardiomyopathy with several time-dependent clinical presentations. The clinical characteristics depend on the penetration grade of the disease. There are two different histological patterns consisting of a lipomatous and a fibrolipomatous form. The presence of arrhythmias in the ARVD syndrome constitutes an important risk factor for sudden cardiac death in athletes. In this article, we describe two professional endurance athletes who died suddenly. One of these athletes had asymptomatic ARVD, the other had symptomatic polymorphic ventricular tachycardias. Both athletes showed fatty penetration of the disease in both the right and left ventricle; one of them also showed fatty involvement at the atrial level and in the other there were signs of myocarditis consistent with ARVD. In the last few years magnetic resonance imaging has become an important diagnostic tool in patients with ARVD.  相似文献   

15.
16.
The purpose of this study was to measure the changes and rates of adaptation of left ventricular volumes at the onset of exercise. Eight asymptomatic subjects, in whom intramyocardial markers had been implanted 3-6 years previously during aortocoronary bypass surgery, exercised in the supine position at a constant workload of 73.6 W for 5 min. Six also exercised first at 16.4 W, and then against a workload which progressively increased by 8.2 W every 15 s. Cardiac volumes were measured by computer assisted analysis of the motion of the implanted markers. In the constant workload test, cardiac output increased rapidly from 5.7 +/- 1 min-1 to 10.3 +/- 1.9 1 min-1 by 2 min and then increased more slowly to 10.8 +/- 2.0 1 min-1 by 5 min. The cardiac output increase was mainly due to an increase in heart rate from 68 +/- 12 beats min-1 to 120 +/- 16 beats min-1 with minimal changes in stroke volume. The time constant for the early increase in cardiac output was 45s and for heart rate, 35s. With progressively increasing workloads, there was an almost linear increase of heart rate and cardiac output, but these increased at a slower rate than during the early phase of the constant load exercise test. In conclusion: rapid changes in cardiac output during supine exercise were produced by changes in heart rate; changes in stroke volume provided minor adjustments to cardiac output; the end-diastolic volume was almost constant.  相似文献   

17.
A 59-year-old asymptomatic male was referred to our hospital for evaluation 44 years after surgical correction of a Fallot’s tetralogy. Transthoracic echocardiography showed a good surgical result with only a mild subvalvular pulmonary stenosis and mild pulmonary regurgitation. However, in the parasternal short axis a diastolic colour Doppler flow was seen in the right ventricular outflow tract with a maximum velocity over 4 m/s (figure 1). Pulmonary regurgitation seemed very unlikely because of the high velocity in the absence of elevated pulmonary artery pressure. Because a fistula was suspected, a multislice computer tomography scan was performed.  相似文献   

18.
To assess the reliability of conductance (G) catheter for evaluating right ventricular (RV) volume changes, a miniature (3.5F) six-electrode catheter was developed and tested in 11 New Zealand rabbit hearts. In five animals the heart was excised; in six it was left in the thorax. RV conductance was recorded while the RV was filled with blood in 0.25-ml steps at different left ventricular (LV) volumes. Linear correlation of measured conductance vs. reference volumes was computed. RV conductance was highly correlated with reference volume [correlation coefficient (r) ranging from 0.991 to 0.999]. Slope of regression lines was not significantly affected by LV volume variations in 1-ml steps or by acute conductance changes of structures surrounding the heart, whereas the intercept was affected only by the 0- to 1-ml LV volume change. In four rabbits, RV conductance changes during a cardiac cycle [stroke volume- (SV) G] were compared in vivo with electromagnetic flow probe-derived estimates of SV (SVem) as stroke volume was varied by graded inferior vena caval occlusion. SV-G correlated well with SVem (r ranging from 0.92 to 0.96). This correlation persisted after the thorax was filled with saline; however, significant differences were found in individual slopes (P < 0.001). These results show that the conductance catheter has a potential to reliably monitor in vivo relative RV volume changes in small-animal hearts.  相似文献   

19.
20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号