首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Tetrahydrocannabinol (THC) is an important psychoactive ingredient in marijuana, which is the most widely used illegal recreational drug in the USA. Since it is generally smoked, the constituents of the plant material, as well as THC may be present in oral fluid specimens collected for the purposes of drug testing. We present an analytical procedure for the simultaneous determination of the pyrolytic precursor Delta(9)-tetrahydrocannabinolic acid A, tetrahydrocannabinol, cannabinol and cannabidiol in human oral fluid specimens using gas chromatography mass spectrometry (GC/MS). Solid phase extraction and GC/MS/EI with selected ion monitoring were used, and the linearity of the method ranged from 0-16 ng/mL of neat oral fluid. The recovery of the cannabinoids from the collection pad into the transportation buffer was greater than 70% for all cannabinoids tested at 4 ng/mL, and the intra- and inter-day precision was less than 10.3 and 15.2% for all analytes. The stability of the drugs in oral fluid and of the extracted derivatives was investigated. The procedure was applied to oral fluid specimens taken from habitual marijuana smokers. We have previously reported the presence of the metabolite 11-nor-Delta(9)-tetra-hydrocannabinol-9-carboxylic acid in oral fluid, but this is the first report of the plant constituent 2-carboxy-THC being detected in saliva.  相似文献   

2.
An analytical procedure for the determination of phencyclidine in oral fluid has been developed and validated using liquid chromatography with tandem mass spectral detection, following initial screening with enzyme linked immunosorbent assay. The oral fluid samples were collected using the Quantisal device, and any drugs present were quantified using mixed mode solid-phase extraction followed by mass spectrometric detection in positive atmospheric pressure chemical ionization mode. For confirmation, two transitions were monitored and one ratio determined, which had to be within 20% of that of the known calibration standard. The monitoring of the qualifying transition and requirement for its presence within a specific ratio to the primary ion has the potential of limiting the sensitivity of the assay, however, the additional confidence in the final result as well as forensic defensibility were considered to be of greater importance. The limit of quantitation was 5ng/mL; the intra-day precision of the assay (n=5) was 3.04%; inter-day precision 3.35% (n=5) at a concentration of 10ng/mL. The accuracy was determined at four concentrations (5, 10, 20 and 40ng/mL) within the linear range of the assay. The percentage recovery of phencyclidine from the oral fluid collection pad was 81.7% (n=6). The methods were applied to both proficiency specimens and to samples obtained during research studies in the USA.  相似文献   

3.
We describe a rapid GC/MS assay for amphetamine-type stimulant drugs (ATSs) and structurally related common medicaments in blood, serum, oral fluid and urine samples. The drugs were extracted from their matrices and derivatized with heptafluorobutyric anhydride (HFBA) in a single step, using the following procedure: 100 microl (oral fluid) or 200 microl (blood, serum, urine) of the sample were mixed with 50 microl of alkaline buffer and 500 microl of extraction-derivatization reagent (toluene + HFBA + internal standard), centrifuged, and injected into a GC/MS apparatus. As revealed by the validation data this procedure, with its limit of quantitation being set at 20 ng/ml for oral fluid, 25 ng/ml for blood or 200 ng/ml for urine, is suitable for screening, identification and quantitative determination of the ATSs and related drugs in all the matrices examined. Thus, time-consuming and expensive multiple analyses are not needed, unless specifically required.  相似文献   

4.
Nicotine is rapidly and extensively metabolized in humans. We present an analytical method to simultaneously quantify nicotine, cotinine, norcotinine, and trans-3'-hydroxycotinine in human oral fluid. Solid phase extraction (SPE) and GC/MS/EI with selected ion monitoring (SIM) were utilized. Linearity ranged from 5 to 1000 ng/mL of oral fluid; correlation coefficients for calibration curves were >0.99. Recoveries were 90-115% nicotine, 76-117% cotinine, 88-101% norcotinine, and 67-77% trans-3'-hydroxycotinine. Intra-assay precision and accuracy ranged from 1.6 to 5.7% and 1.6 to 17.8%, respectively. Inter-assay precision and accuracy ranged from 4.3 to 10.2% and 0 to 12.8%, respectively. Suitable precision and accuracy were achieved for the simultaneous determination of nicotine and three metabolites in the oral fluid of smokers. This assay is applicable to pharmacokinetic studies of nicotine, cotinine, and trans-3'-hydroxycotinine from tobacco smokers and can be utilized for routine monitoring of tobacco smoke exposure. 3-Hydroxycotinine requires additional investigation to determine its usefulness as a biomarker for tobacco smoke exposure.  相似文献   

5.
A method that allows the measurement of plasma and brain levels of the centrally-acting analgesic tramadol and its major metabolite (O-desmethyl tramadol) in mice and rats was developed using gas chromatography equipped with nitrogen–phosphorus detection (GC–NPD). Plasma samples were extracted with methyl tert.-butyl ether (MTBE) and were injected directly into the GC system. Brain tissue homogenates were precipitated with methanol, the resulting supernatant was dried then acidified with hydrochloric acid. The aqueous solution was washed with MTBE twice, alkalinized, and extracted with MTBE. The MTBE layer was dried, reconstituted and injected into the GC system. The GC assay used a DB-1 capillary column with an oven temperature ramp (135 to 179°C at 4°C/min). Dextromethorphan was used as the internal standard. The calibration curves for tramadol and O-desmethyl tramadol in plasma and brain tissue were linear in the range of 10 to 10 000 ng/ml (plasma) and ng/g (brain). Assay accuracy and precision of back calculated standards were within ±15%.  相似文献   

6.
A fully validated gas chromatographic–tandem mass spectrometric (GC–MS–MS) method is described for the accurate determination of acetylsalicylic acid (ASA) in human plasma after a single low-dose oral administration of aspirin or guaimesal, an ASA releasing prodrug. ASA and the newly prepared O-[2H3]-acetylsalicylic acid (d3-ASA) used as internal standard were determined in 100-μl aliquots of plasma by extractive pentafluorobenzyl (PFB) esterification using PFB bromide and tetrabutylammoniumhydrogen sulphate as the esterifying and ion-pairing agent, respectively, and by GC–MS–MS analysis in the negative-ion chemical ionization mode. The overall relative standard deviations were below 8% for ASA levels in the range 0–1 μg/ml plasma. Mean accuracy was 3.8% for ASA levels within the range 0–100 ng/ml. The limit of quantitation of the method was determined as 200 pg/ml ASA at an accuracy of 5.5% and a precision of 15.2%. The limit of detection was determined as 546 amol of ASA at a signal-to-noise ratio of 10:1.  相似文献   

7.
The purpose of this study was to develop a sublingual spray drug delivery formulation of oxycodone and evaluate the effect of formulation pH on sublingual absorption of oxycodone for acute pain management using rabbit as the animal model. Using a new, sensitive, and specific liquid chromatography/mass spectrometry (LC/MS) with electrospray ionization detector assay, the absorption bioavailability of sublingual oxycodone was determined in rabbits by comparing plasma concentration after sublingual spray delivery with equivalent intravenous dose. The effect of formulation pH on sublingual absorption of oxycodone was also tested on rabbits that had received oxycodone sublingually at a dose of 0.1 mg/0.1 mL (pH 4.0 and 9.0). Blood samples were collected at different time points, and plasma oxycodone concentrations were determined by LC/MS. Following administration of a 0.1 mg dose, the average Cmax values were found to be 64.9±12.1 and 95.2±10.1 ng/mL, for pH 4.0 and 9.0, respectively. The area under the curve (AUC) values were found to be 5807.0, and 8965.3 ng.min/mL for formulation pH 4.0 and 9.0, respectively. The mean sublingual bioavailability of oxycodone was 45.4%±20.1% and 70.1%±17.9%, for pH 4.0 and 9.0, respectively. the formulation pH had no significant influence on oxycodone bioavailability (P<.05). A sublingual spray dosage form of oxycodone hydrochloride would be a good alternative for fast onset pain management, especially in children. Published: March 10, 2006  相似文献   

8.
Oral fluid is of increasing interest as an alternative sample matrix in drugs of abuse analysis. Compared to the conventional sample matrix blood, sample volumes of oral fluid are smaller and the concentrations of some drugs can be much lower. This imposes some restrictions on the analysis method, which has to be able to detect and quantify multiple analytes from a small sample volume at low concentrations. A sensitive multi-component method for quantitative determination of 50 drug compounds from oral fluid samples collected with the StatSure SalivaSampler? device was developed. The compounds analysed include cannabis, cocaine, amphetamines, opioids, benzodiazepines and other psychoactive medicines. Both liquid–liquid-extraction (LLE) and solid-phase-extraction (SPE) are employed in the sample pre-treatment and the samples are analysed using gas chromatography–mass spectrometry (GC–MS) with the mass selective detector (MSD) operating in either electron ionization (EI) or negative-ion chemical ionization (NICI) mode. The method was fully validated, and the validated parameters included linearity, selectivity, accuracy, precision, and extraction efficiency. Stability of the collected samples during storage at ?18 °C was also studied, and even after over a year's storage all analyte concentrations were more than 60% of the original concentrations. The described method is suitable for routine analysis of oral fluid samples and it has been applied to analysis of more than 4000 oral fluid samples collected anonymously from volunteer road users in Finland during 2007–2009 as a part of the EU project DRUID (Driving under the Influence of Drugs, Alcohol and Medicines). At the moment the developed method is the most comprehensive validated analysis method for oral fluid samples.  相似文献   

9.
A method was developed for the quantification of matrine in human plasma using a liquid-liquid extraction procedure followed by gas-chromatography-mass spectrometry (GC/MS) analysis. Deuterated matrine, an internal standard of the analysis, was spiked into the plasma samples before extraction. Linear detection responses were obtained for matrine concentrations ranging from 10 to 500 ng/ml. The intra-day and inter-day precision ranged from 0.4 to 4.0% and 1.0-3.5%, respectively. The intra-day accuracy was between -7.3 and 4.5%. The limit of quantification for matrine was 23 ng/ml. The extraction efficiency averaged about 38%. The validated GC/MS method will be used to quantify matrine in human plasma samples collected in a clinical trial study.  相似文献   

10.
Orally administered testosterone undecanoate (TU), an anabolic, androgenic steroid, can potentially be abused by athletes. Indirect evidence for detecting oral TU intake could be deduced from the changes in steroid profile post-administration. Direct evidence could be obtained by detection of unchanged TU in plasma. To this end, both urinary and plasma steroid profiles of six healthy male subjects given a single oral dose of 120 mg of TU were studied by gas chromatography/mass spectrometry (GC/MS) and gas chromatography/tandem mass spectrometry (GC/MS/MS). The increased concentration of glucuronidated testosterone in plasma appears to be the most characteristic sign of oral TU intake. The testosterone glucuronide (TG)/nonconjugated testosterone (T) ratio, TG/17-hydroxyprogesterone (17OHP) ratio, and TG/luteinizing hormone (LH) ratio were observed to be significantly elevated above their basal levels for 10 h, 10 h, and 6 h, respectively. Urinary ratios of TG/epitestosterone glucuronide (EG) were found to be higher than the cut-off value of 6 for the period 4 approximately 8 h post-administration, but only in three subjects. One subject failed to respond with respect to all of the above-mentioned indirect markers, as TG was not significantly increased in either plasma or urine. Unchanged TU was directly detected in plasma of all six subjects from 1 approximately 1.5 h to 4 approximately 6 h after oral TU intake by GC/MS/MS, providing unequivocal proof of exogenous testosterone intake. Distinct and complementary markers for detecting oral TU intake could be obtained from plasma and urine, respectively.  相似文献   

11.
An HPLC system using a simple liquid-liquid extraction and HPLC with UV detection has been validated to determine tramadol concentration in human plasma. The method developed was selective and linear for concentrations ranging from 10 to 2000 ng/ml with average recovery of 98.63%. The limit of quantitation (LOQ) was 10 ng/ml and the percentage recovery of the internal standard phenacetin was 76.51%. The intra-day accuracy ranged from 87.55 to 105.99% and the inter-day accuracy, 93.44 to 98.43% for tramadol. Good precision (5.32 and 6.67% for intra- and inter-day, respectively) was obtained at LOQ. The method has been applied to determine tramadol concentrations in human plasma samples for a pharmacokinetic study.  相似文献   

12.
A method using liquid chromatography coupled to tandem mass spectrometry is described for the determination of drugs of abuse in oral fluid. The method is able to simultaneously quantify amphetamines (amphetamine, methamphetamine, MDA, MDMA and MDEA), opiates (morphine and codeine), cocaine and benzoylecgonine. Only 200 micro of oral fluid is spent for analysis. The sample preparation is easy and consists of mixed mode phase solid-phase extraction. Reversed-phase chromatography is carried out on a narrow bore phenyl type column at a flow-rate of 0.2 ml/min. A gradient is applied ranging from 6 to 67.6% methanol with ammonium formate (10 mM, pH 5.0) added to the mobile phase. The column effluent was directed into a quadrupole-time-of-flight instrument by electrospray ionization, without the use of a splitter. A validation study was carried out. Recovery ranged from 52.3 to 98.8%, within-day and between-day precision expressed by relative standard deviation were less than 11.9 and 16.8%, respectively, and inaccuracy did not exceed 11.6%. The limit of quantification was 2 ng/ml (0.66 x 10(-5)-1.48 x 10(-5) M) for all compounds. Internal standards were used to generate quadratic calibration curves (r(2)>0.999). The method was applied to real samples obtained from suspected drug users. An interference was observed from the device used to sample the oral fluid, consequently this was excluded from the method which was validated on oral fluid obtained by spitting in a test-tube.  相似文献   

13.
A stereospecific method for simultaneous quantitation of the enantiomers of tramadol (T) and its active metabolites O-demethyl tramadol (M1) and O-demethyl-N-demethyl tramadol (M5) in human plasma is reported. After the addition of penbutolol (IS), plasma (0.5 ml) samples were extracted into methyl tert-butyl ether, followed by back extraction into an acidic solution. The separation was achieved using a Chiralpak AD column with a mobile phase of hexanes:ethanol:diethylamine (94:6:0.2) and a flow rate of 1 ml/min. The fluorescence of analytes was then detected at excitation and emission wavelengths of 275 and 300 nm, respectively. All the six enantiomeric peaks of interest plus three unknown metabolite peaks and IS peak (a total of 10 peaks) eluted within 23 min, free from endogenous interference. The assay was validated in the plasma concentration range of 2.5-250 ng/ml, with a lower limit of quantitation of 2.5 ng/ml, for all the six analytes. The extraction efficiency (n=5) was close to 100% for both T and M1 enantiomers and 85% for M5 and IS enantiomers. The application of the assay was demonstrated by simultaneous measurement of plasma concentrations of T, M1, and M5 enantiomers in a healthy volunteer after the administration of 50 mg oral doses of racemic T.  相似文献   

14.
A liquid chromatography tandem mass spectrometry (LC-MS-MS) method for determination of the analgesic aminophenol ketobemidone in human plasma is presented. Two preparation methods for plasma samples containing ketobemidone were compared, liquid-liquid extraction (LLE) and solid-phase extraction (SPE). Both methods showed good precision (n=10), 1.7% and 2.9%, respectively (0.04 micro M) and 1.1% and 2.5%, respectively (0.14 micro M). The accuracy was 98% and 103%, respectively (0.04 micro M) and 105% and 99%, respectively (0.14 micro M). Ketobemidone could be quantified at 0.43 nM, with a relative standard deviation of 17.5% (n=19) using LLE and 18.6% (n=10) using SPE. This level was an order of magnitude lower than earlier reported quantification limits. Quantitative data from plasma samples analyzed with LC-MS-MS were in good agreement with those obtained by gas chromatography with chemical ionization mass spectrometry (GC-CI/MS). This indicates that LC-MS-MS is a good alternative method to GC-MS as it is more sensitive and time-consuming derivatization can be avoided.  相似文献   

15.
The essential oil from fresh leaves of Thuja orientalis L. grown in the north-western Himalaya was isolated by means of hydrodistillation and analyzed by GC and GC/MS. Twenty-two compounds representing 94.0% of the total oil were identified. The leaf oil contained alpha-pinene (29.2%), Delta-3-carene (20.1%), alpha-cedrol (9.8%), caryophyllene (7.5%), alpha-humulene (5.6%), limonene (5.4%), alpha-terpinolene (3.8%) and alpha-terpinyl acetate (3.5%) as major constituents. The essential oil showed antifungal activity against Alternaria alternata in a direct bioautography assay. Two main bioactive compounds named as b1 (Rf = 0.54) and b2 (Rf = 0.80) were observed and tested for antifungal activity; they produced an inhibition zone of 5 and 10 mm in diameter, respectively. The components b1 and b2 were further purified by preparative thin layer chromatography and their antifungal efficacy was re-tested. The minimum inhibitory amount (MIA) of b1 and b2 against A. alternata was determined as 30.5 and 4.5 microg, respectively, using a bioautography assay. The bioactive constituent corresponding to b1 was determined as alpha-cedrol by using GC/MS analysis. The potential of essential oils as a source of natural biocides is discussed.  相似文献   

16.
Tetramethylene disulfotetramine (tetramine) is a rodenticide associated with numerous poisonings was extracted and quantified in human urine using both gas chromatography/mass spectrometry (GC/MS) and GC/tandem mass spectrometry (MS/MS). 1200 μL samples were prepared using a 13C4-labeled internal standard, a 96-well format, and a polydivinyl-benzene solid phase extraction sorbent bed. Relative extraction recovery was greater than 80% at 100 ng/mL. Following extraction, samples were preconcentrated by evaporation at 60 °C, and reconstituted in 50 μL acetonitrile. One-microliter was injected in a splitless mode on both instruments similarly equipped with 30 m × 0.25 mm × 25 μm, 5% phenyl-methylpolysiloxane gas chromatography columns. A quantification ion and a confirmation ion (GC/MS) or analogous selected reaction monitoring transitions (GC/MS/MS) were integrated for all reported results. The method was characterized for precision (5.92–13.4%) and accuracy (96.4–111%) using tetramine-enriched human urine pools between 5 and 250 ng/mL. The method limit of detection was calculated to be 2.34 and 3.87 ng/mL for GC/MS and GC/MS/MS, respectively. A reference range of 100 unexposed human urine samples was analyzed for potential endogenous interferences on both instruments—none were detected. Based on previous literature values for tetramine poisonings, this urinary method should be suitable for measuring low, moderate, and severe tetramine exposures.  相似文献   

17.
Interaction of reactive oxygen species with DNA results in a variety of modifications, including 8-oxo-7,8-dihydro-2'-deoxyguanosine (8-oxodG), which has been extensively studied as a biomarker of oxidative stress. Oxidative stress is implicated in a number of pathophysiological processes relevant to obstetrics and gynecology; however, there is a lack of understanding as to the precise role of oxidative stress in these processes. We aimed to develop a rapid, validated assay for the accurate quantification of 8-oxodG in human urine using solid-phase extraction and ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) and then investigate the levels of 8-oxodG in several fluids of interest to obstetrics and gynecology. Using UHPLC-MS/MS, 8-oxodG eluted after 3.94 min with an RSD for 15 injections of 0.07%. The method was linear between 0.95 and 95 nmol/L with LOD and LOQ of 5 and 25 fmol on-column, respectively. Accuracy and precision were 98.7-101.0 and <10%, respectively, over three concentrations of 8-oxodG. Recovery from urine was 88% with intra- and interday variations of 4.0 and 10.2%, respectively. LOQ from urine was 0.9 pmol/ml. Rank order from the greatest to lowest 8-oxodG concentration was urine>seminal plasma>amniotic fluid>plasma>serum>peritoneal fluid, and it was not detected in saliva. Urine concentrations normalized to creatinine (n=15) ranged between 0.55 and 1.95 pmol/μmol creatinine. We describe, for the first time, 8-oxodG concentrations in human seminal plasma, peritoneal fluid, amniotic fluid, and breast milk, as well as in urine, plasma, and serum, using a rapid UHPLC-MS/MS method that will further facilitate biomonitoring of oxidative stress.  相似文献   

18.
Currently available radioimmunoassay methods for estradiol in serum lack sufficient sensitivity and precision to monitor estradiol levels in patients placed on third generation aromatase inhibitors. We recently validated a gas chromatography/tandem mass spectrometry assay (GC/MS/MS) for estradiol and determined estrogen levels in normal post-menopausal women and in women with breast cancer before and during administration of aromatase inhibitors. Validation of the GC/MS/MS assay in human plasma and human serum included determination of assay sensitivity (<0.63 pg/ml), precision (all CVs less than 17.8%), recovery (98-103%), and linearity of recovery (R=0.998). Levels of estradiol were lower when assayed by GC/MS/MS compared to RIA under all conditions (7.26+/-4.82 pg/ml versus 11.9+12.0 pg/ml in normal post-menopausal women; 5.88+/-3.43 pg/ml versus 13.8+/-7.5 pg/ml in breast cancer patients prior to treatment; and<0.63 pg/ml versus 5.8+/-4.1 pg/ml during aromatase inhibitor therapy). Fifty-five women treated either with atamestane/toremiphene or letrozole/placebo were monitored for estradiol levels at 4, 8 and 12 weeks of therapy. The mean levels of estradiol during aromatase inhibitor therapy was 5.8+/-4.1 pg/ml as measured by RIA and <0.63 pg/ml by GC/MS/MS. The degree of suppression with the aromatase inhibitors as detected by RIA was 58% versus >89% by GC/MS. These results suggest that most RIA methods detect cross-reacting estrogen metabolites and yield higher measured levels than GC/MS/MS. Several pharmacological and clinical considerations suggest that GC/MS/MS should become the preferred method for monitoring aromatase inhibitor therapy.  相似文献   

19.
Cathepsins are involved in a variety of physiological processes including antigen processing and presentation and extracellular matrix degradation. In the present study, we evaluated whether expression levels of cathepsins S and B and their inhibitors cystatins B and C are affected by multiple sclerosis (MS) disease state (relapse and remission) and therapies (interferon-β [IFN-β] and the glucocorticoid [GC] methylprednisolone), and whether they are associated with the IFN-β response phenotype. Real-time PCR was employed to compare RNA expression levels in peripheral blood leucocytes (PBLs) and ELISA to determine serum protein levels of MS patients and matched healthy individuals. Cathepsin S RNA was higher in MS patients in the relapse state compared to controls (by 74%, P = 3 × 10(-5), n = 30 versus n = 18) with a similar increase observed in serum (66%, P = 0.002, n = 18 versus n = 20). GC treatment reduced cathepsin S levels in PBL RNA (by 44%, P = 6 × 10(-6), n = 27) and serum proteins (by 27%, P = 1 × 10(-5), n = 26), reduced the serum protein levels of pro-cathepsin B (by 8%, P = 0.0007, n = 23), and in parallel increased the serum levels of their inhibitor cystatin C (by 82%, P = 8 × 10(-6), n = 26). IFN-β therapy significantly elevated the RNA levels (n = 16) of cathepsin B (by 16%, P = 0.03), cystatin B (44%, P = 0.004) and cystatin C (48%, P = 0.011). In the serum, only cathepsin S levels were reduced by IFN-β (16%, P = 0.006, n = 25). Interestingly, pre-treatment serum cathepsin S/cystatin C ratio was higher in 'good responders' to IFN-β therapy compared to patients without a good response (by 94%, P = 0.003). These results suggest that cathepsin S and cystatin C may contribute to disease activity in MS, specifically in a subgroup of patients that are responsive to IFN-β therapy, and that these proteins should be further evaluated as biomarkers in MS.  相似文献   

20.
A high throughput and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed and validated for the estimation of bisoprolol in human plasma using multiplexing technique (two HPLC units connected to one MS). Bisoprolol was extracted from human plasma using solid-phase extraction technique using metoprolol as internal standard. A Betabasic 8 column provided chromatographic separation of analytes followed by detection with mass spectrometry. The mass transition ion-pair was followed as m/z 326.2-->116.1 for bisoprolol and m/z 268.2-->191.0 for metoprolol. The method involves a simple multiplexing, rapid solid-phase extraction, simple isocratic chromatography conditions and mass spectrometric detection which enable detection at sub-nanogram levels. The proposed method has been validated for a linear range of 0.5-70.0 ng/mL with correlation coefficient > or =0.9991. The precision and accuracy were within 10% for intra-HPLC runs and inter-HPLC runs. The overall recoveries for bisoprolol and metoprolol were 93.89% and 77.65%, respectively. Total MS run time was 0.90 min only. The developed method was applied for the determination of pharmacokinetic parameters of bisoprolol following a single oral administration of a 10mg bisoprolol tablet in 18 healthy male volunteers.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号