首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The purposes of this study were to compare the elasticity of tendon and aponeurosis in human knee extensors and ankle plantar flexors in vivo and to examine whether the maximal strain of tendon was correlated to that of aponeurosis. The elongation of tendon and aponeurosis during isometric knee extension (n = 23) and ankle plantar flexion (n = 22), respectively, were determined using a real-time ultrasonic apparatus, while the participants performed ramp isometric contractions up to voluntary maximum. To calculate the strain values from the measured elongation, we measured the respective length of tendon and aponeurosis. For the knee extensors, the maximal strain of aponeurosis (12.1 +/- 2.8 %) was significantly greater than that of the patella tendon (8.3 +/- 2.4 %), p < 0.001. On the contrary, the maximal strain of Achilles tendon (5.9 +/- 1.4 %) was significantly greater than that of aponeurosis in ankle plantar flexors (2.7 +/- 1.4 %), p < 0.001. Furthermore, for both knee extensors and ankle plantar flexors there was no significant correlation between maximal strain of tendon and aponeurosis. These results would be important for understanding the different roles of tendon and aponeurosis during human movements and for more accurate muscle modeling.  相似文献   

2.
The effect of a lathyritic diet on the sensitivity of tendon to strain rate   总被引:1,自引:0,他引:1  
While the tensile failure properties of rat-tail tendon depend on strain rate, the sensitivity to strain rate decreases with age, especially during sexual maturation. The object of this study was to determine the effect of an experimental model of chronic lathyrism on age-dependent changes in the sensitivity of developing tendon strength to strain rate. Tensile failure experiments were conducted at high and low strain rate on tendons excised from test and control animals aged 1 to 6 mo. The tensile "yield" response of tendon was significantly affected by the diet resulting in a reduced tensile strength and failure strain. While the sensitivity of tendon failure to strain rate was slightly elevated by the experimental diet, age-dependent changes compared with controls. Since the diet supplement is thought to inhibit covalent crosslinking of collagen in the developing tendon, other factors are likely responsible for decrease in the sensitivity of tendon strength to strain rate during maturation.  相似文献   

3.
Regarding the strain and elongation distribution along the tendon and aponeurosis the literature is reporting different findings. Therefore, the purpose of this study was to examine in vivo the elongation and the strain of the human gastrocnemius medialis tendon and aponeurosis simultaneously at the same trial during maximal voluntary plantarflexion efforts. Twelve subjects participated in the study. The subjects performed isometric maximal voluntary contractions of their left leg on a Biodex-dynamometer. The kinematics of the leg were recorded using the Vicon 624 system with 8 cameras operating at 120 Hz. Two ultrasound probes were used to visualise the tendon (myotendinous junction region) and the distal aponeurosis of the gastrocnemius medialis respectively. The main findings were: (a) the absolute elongation of the gastrocnemius medialis tendon was different to that of the aponeurosis, (b) the strain of the gastrocnemius medialis tendon did not differ from the strain of the aponeurosis, (c) during the "isometric" plantarflexion the ankle angle exhibited significant changes, and (d) the non-rigidity of the dynamometer arm-foot system and the coactivity of the tibialis anterior both have a significant influence on the moment exerted at the ankle joint. Thus the strain of the human gastrocnemius medialis tendon and aponeurosis estimated in vivo using two-dimensional ultrasonography is uniform. To calculate the elongation of the whole tendon it is necessary to multiply the strain calculated for the examined part of the tendon by the total length of the tendon.  相似文献   

4.
Those techniques for measuring ligament tension at the knee joint that are most commonly cited and easiest to carry out are discussed. These include four techniques based on the use of strain gauges. Apart from the Omega transducer and the buckle transducer, there is also the tendon force transducer, and the application of strain gauges to the bony ligament insertion sites. Other indirect measuring methods considered are the mercury strain transducer and the Hall effect transducer. The parameter measured with all of these methods is fluctuating current or voltage, which is then correlated with ligament tension. Three direct measurements are also discussed: the separation distances of marked fibres of the ligaments, replacement of fibres by threads, and a load cell/bone plug construction. The measured value is equated with the effective change in ligament length.  相似文献   

5.
Supraspinatus tendon tears are common and often propagate into larger tears that include the infraspinatus tendon, resulting in loss of function and increased pain. Previously, we showed that the supraspinatus and infraspinatus tendons mechanically interact through a range of rotation angles, potentially shielding the torn supraspinatus tendon from further injury while subjecting the infraspinatus tendon to increased risk of injury. Surgical repair of torn supraspinatus tendons is common, yet the effect of the repair on the infraspinatus tendon is unknown. Since we have established a relationship between strain in the supraspinatus and infraspinatus tendons the success of a supraspinatus tendon repair depends on its effect on the loading environment in the infraspinatus tendon. More specifically, the effect of transosseous supraspinatus tendon repair in comparison to one that utilizes suture anchors, as is commonly done with arthroscopic repairs, on this interaction through these joint positions will be evaluated. We hypothesize that at all joint positions evaluated, both repairs will restore the interaction between the two tendons. For both repairs, (1) increasing supraspinatus tendon load will increase infraspinatus tendon strain and (2) altering the rotation angle from internal to external will increase strain in the infraspinatus tendon. Strains were measured in the infraspinatus tendon insertion through a range of joint rotation angles and supraspinatus tendon loads, for the intact, transosseous, and suture anchor repaired supraspinatus tendons. Images corresponding to specific supraspinatus tendon loads were isolated for the infraspinatus tendon insertion for analysis. The effect of supraspinatus tendon repair on infraspinatus tendon strain differed with joint position. Altering the joint rotation did not change strain in the infraspinatus tendon for any supraspinatus tendon condition. Finally, increasing supraspinatus tendon load resulted in an increase in average maximum and decrease in average minimum principal strain in the infraspinatus tendon. There is a significant difference in infraspinatus tendon strain between the intact and arthroscopically (but not transosseous) repaired supraspinatus tendons that increases with greater loads. Results suggest that at low loads neither supraspinatus tendon repair technique subjects the infraspinatus tendon to potentially detrimental loads; however, at high loads, transosseous repairs may be more advantageous over arthroscopic repairs for the health of the infraspinatus tendon. Results emphasize the importance of limiting loading of the repaired supraspinatus tendon and that at low loads, both repair techniques restore the interaction to the intact supraspinatus tendon case.  相似文献   

6.
Mechano-regulation during tendon healing, i.e. the relationship between mechanical stimuli and cellular response, has received more attention recently. However, the basic mechanobiological mechanisms governing tendon healing after a rupture are still not well-understood. Literature has reported spatial and temporal variations in the healing of ruptured tendon tissue. In this study, we explored a computational modeling approach to describe tendon healing. In particular, a novel 3D mechano-regulatory framework was developed to investigate spatio-temporal evolution of collagen content and orientation, and temporal evolution of tendon stiffness during early tendon healing. Based on an extensive literature search, two possible relationships were proposed to connect levels of mechanical stimuli to collagen production. Since literature remains unclear on strain-dependent collagen production at high levels of strain, the two investigated production laws explored the presence or absence of collagen production upon non-physiologically high levels of strain (>15%). Implementation in a finite element framework, pointed to large spatial variations in strain magnitudes within the callus tissue, which resulted in predictions of distinct spatial distributions of collagen over time. The simulations showed that the magnitude of strain was highest in the tendon core along the central axis, and decreased towards the outer periphery. Consequently, decreased levels of collagen production for high levels of tensile strain were shown to accurately predict the experimentally observed delayed collagen production in the tendon core. In addition, our healing framework predicted evolution of collagen orientation towards alignment with the tendon axis and the overall predicted tendon stiffness agreed well with experimental data. In this study, we explored the capability of a numerical model to describe spatial and temporal variations in tendon healing and we identified that understanding mechano-regulated collagen production can play a key role in explaining heterogeneities observed during tendon healing.  相似文献   

7.
Tendon stiffness is calculated by dividing changes in tendon force by tendon elongation. For this purpose, participants are commonly asked to perform a maximal muscle contraction (“active” method). Alternatively tendon elongation can be achieved by means of a passive joint rotation (“passive” method). The purpose of this study was to compare Achilles tendon stiffness obtained from both methods across different tendon strain rates. Twenty adults performed a series of ramped maximum isometric plantarflexions of different durations. Passive ankle rotations of different angular velocities were also performed. Achilles tendon stiffness was obtained from a combination of motion analysis, isokinetic dynamometry and ultrasonography and compared across methods at three strain rates. At all strain rates, tendon stiffness obtained from the active method was 6% greater compared to the passive method. In spite of this systematic bias, there was good agreement between the methods. Intraclass correlation coefficients were greater than 0.98, and more than 95% of data points fell into the 95% confidence intervals. This agreement will be acceptable in many research contexts. We also found a linear increase in tendon stiffness with increasing strain rate, which must be taken into consideration when interpreting or reporting tendon stiffness.  相似文献   

8.
Rotator cuff tears are a common tendon injury often requiring surgical treatment. Understanding the relationships between tear size, tendon loading, and tendon strain adjacent to a rotator cuff tear can provide important insights into predicting the likelihood of propagation to larger tears which would influence clinical treatment. Previous studies assume that an increase in strain correlates with an increase in risk of tear propagation. However, these studies did not explicitly investigate these important relationships. Therefore, the objective of this study was to quantify two-dimensional strain fields adjacent to a rotator cuff tendon tear under loading to failure and to assess the relationship between tendon strain and tear size. Sheep infraspinatus tendons were used to evaluate the effect of tear size on principal strains in the region adjacent to the tear. The relationship between strain, tear propagation, and the direction of tear propagation was quantified. Results showed that principal strains linearly correlated with tear propagation and that tear propagation began at strains as low as 1.7%. In addition, tears propagated in the direction of highest maximum and lowest minimum principal strain. Finally, maximum and minimum principal strains were higher and lower, respectively, adjacent to larger tears compared to smaller tears. Findings from this study validate the use of local strain adjacent to a rotator cuff tear as an indicator of the risk and direction of tear propagation.  相似文献   

9.
A precise analysis of the mechanical response of collagen fibrils in tendon tissue is critical to understanding the ultrastructural mechanisms that underlie collagen fibril interactions (load transfer), and ultimately tendon structure–function. This study reports a novel experimental approach combining macroscopic mechanical loading of tendon with a morphometric ultrascale assessment of longitudinal and cross-sectional collagen fibril deformations. An atomic force microscope was used to characterize diameters and periodic banding (D-period) of individual type-I collagen fibrils within murine Achilles tendons that were loaded to 0%, 5%, or 10% macroscopic nominal strain, respectively. D-period banding of the collagen fibrils increased with increasing tendon strain (2.1% increase at 10% applied tendon strain, p < 0.05), while fibril diameter decreased (8% reduction, p < 0.05). No statistically significant differences between 0% and 5% applied strain were observed, indicating that the onset of fibril (D-period) straining lagged macroscopically applied tendon strains by at least 5%. This confirms previous reports of delayed onset of collagen fibril stretching and the role of collagen fibril kinematics in supporting physiological tendon loads. Fibril strains within the tissue were relatively tightly distributed in unloaded and highly strained tendons, but were more broadly distributed at 5% applied strain, indicating progressive recruitment of collagen fibrils. Using these techniques we also confirmed that collagen fibrils thin appreciably at higher levels of macroscopic tendon strain. Finally, in contrast to prevalent tendon structure–function concepts data revealed that loading of the collagen network is fairly homogenous, with no apparent predisposition for loading of collagen fibrils according to their diameter.  相似文献   

10.
Analysis of cumulative strain in tendons and tendon sheaths   总被引:4,自引:1,他引:3  
Twenty-five fresh frozen flexor digitorum profundus tendons stratified by sex were subjected to uniaxial step stress and cyclic loads in twelve intact human cadaver hands. By attaching specially designed clip strain gage transducers on tendons just proximal and distal to an undisrupted carpal tunnel, the interactions of the tendons, tendon sheath and retinacula were measured. The elastic and viscous response of the tendon composites to step stresses were found to fit fractional power functions of stress and time respectively. A significant and quantifiable decrease in strain from the proximal to the distal tendon segment was found to be a function of wrist deviation. The results indicate that an accumulation of strain does occur in tendinous tissues during physiologic loading.  相似文献   

11.
Stress wave velocities in bovine patellar tendon.   总被引:1,自引:0,他引:1  
The velocity of longitudinal stress waves in an elastic body is given by the square root of the ratio of its elastic modulus to its density. In tendinous and ligamentous tissue, the elastic modulus increases with strain and with strain rate. Therefore, it was postulated that stress wave velocity would also increase with increasing strain and strain rate. The purpose of this study was to determine the velocity of stress waves in tendinous tissue as a function of strain and to compare these values to those predicted using the elastic modulus derived from quasi-static testing. Five bovine patellar tendons were harvested and potted as bone-tendon-bone specimens. Quasi-static mechanical properties were determined in tension at a deformation rate of 100 mm/s. Impact loading was employed to determine wave velocity at various strain levels, achieved by preloading the tendon. Following impact, there was a measurable delay in force transmission across the specimen and this delay decreased with increasing tendon strain. The wave velocities at tendon strains of 0.0075, 0.015, and 0.0225 were determined to be 260 +/- 52 m/s, 360 +/- 71 m/s, and 461 +/- 94 m/s, respectively. These velocities were significantly (p < 0.01) faster than those predicted using elastic moduli derived from the quasi-static tests by 52, 45, and 41 percent, respectively. This study has documented that stress wave velocity in patellar tendon increases with increasing strain and is underestimated with a modulus estimated from quasi-static testing.  相似文献   

12.
Achilles tendon material properties and geometry are altered in Achilles tendinopathy. The purpose of this study was to determine the relative contributions of altered material properties and geometry to free Achilles tendon stress distribution during a sub-maximal contraction in tendinopathic relative to healthy tendons. Tendinopathic (n = 8) and healthy tendons (n = 8) were imaged at rest and during a sub-maximal voluntary isometric contraction using three-dimensional freehand ultrasound. Images were manually segmented and used to create subject-specific finite element models. The resting cross-sectional area of the free tendon was on average 31% greater for the tendinopathic compared to healthy tendons. Material properties for each tendon were determined using a numerical parameter optimisation approach that minimised the difference in experimentally measured longitudinal strain and the strain predicted by the finite element model under submaximal loading conditions for each tendon. The mean Young’s modulus for tendinopathic tendons was 53% lower than the corresponding control value. Finite element analyses revealed that tendinopathic tendons experience 24% less stress under the same submaximal external loading conditions compared to healthy tendons. The lower tendon stress in tendinopathy was due to a greater influence of tendon cross-sectional area, which alone reduced tendon stress by 30%, compared to a lower Young’s modulus, which alone increased tendon stress by 8%. These findings suggest that the greater tendon cross-sectional area observed in tendinopathy compensates for the substantially lower Young’s modulus, thereby protecting pathological tendon against excessive stress.  相似文献   

13.
The ultrasonography contributes to investigate in vivo tendon force-strain relationship during isometric contraction. In previous studies, different methods are available to estimate the tendon strain, using different loading rates and models to fit the tendon force-strain relationship. This study was aimed to propose a standard method to characterize the in vivo tendon force-strain relationship. We investigated the influence on the force-strain relationship for medialis gastrocnemius (MG) of (1) one method which takes into account probe and joint movements to estimate the instantaneous tendon length, (2) models used to fit the force-strain relationship for uniaxial test (polynomial vs. Ogden), and (3) the loading rate on tendon strain. Subjects performed ramp-up contraction during isometric contractions at two different target speeds: 1.5s and minimal time with ultrasound probe fixed over the muscle-tendon junction of the MG muscle. The used method requires three markers on ultrasound probe and a marker on calcaneum to take into account all movements, and was compared to the strain estimated using ultrasound images only. The method using ultrasound image only overestimated the tendon strain from 40% of maximal force. The polynomial model showed similar fitting results than the Ogden model (R2=0.98). A loading rate effect was found on tendon strain, showing a higher strain when loading rate decreases. The characterization of tendon force-strain relationship needs to be standardized by taking into account all movements to estimate tendon strain and controlling the loading rate. The polynomial model appears to be appropriate to represent the tendon force-strain relationship.  相似文献   

14.
The goal of the current study was to investigate the fidelity of a 2D ultrasound elastography method for the measurement of tendon motion and strain. Ultrasound phantoms and ex vivo porcine flexor tendons were cyclically stretched to 4% strain while cine ultrasound radiofrequency (RF) data and video data were simultaneously collected. 2D ultrasound elastography was used to estimate tissue motion and strain from RF data, and surface tissue motion and strain were separately estimated using digital image correlation (DIC). There were strong correlations (R2>0.97) between DIC and RF measurements of phantom displacement and strain, and good agreement in estimates of peak phantom strain (DIC: 3.5±0.2%; RF: 3.7±0.1%). For tendon, elastographic estimates of displacement profiles also correlated well with DIC measurements (R2>0.92), and exhibited similar estimated peak tendon strain (DIC: 2.6±1.4%; RF: 2.2±1.3%). Elastographic tracking with B-Mode images tended to under-predict peak strain for both the phantom and tendon. This study demonstrates the capacity to use quantitative elastographic techniques to measure tendon displacement and strain within an ultrasound image window. The approach may be extendible to in vivo use on humans, which would allow for the non-invasive analysis of tendon deformation in both normal and pathological states.  相似文献   

15.
Muscles attach to bones via tendons that stretch and recoil, affecting muscle force generation and metabolic energy consumption. In this study, we investigated the effect of tendon compliance on the metabolic cost of running using a full-body musculoskeletal model with a detailed model of muscle energetics. We performed muscle-driven simulations of running at 2–5 m/s with tendon force–strain curves that produced between 1 and 10% strain when the muscles were developing maximum isometric force. We computed the average metabolic power consumed by each muscle when running at each speed and with each tendon compliance. Average whole-body metabolic power consumption increased as running speed increased, regardless of tendon compliance, and was lowest at each speed when tendon strain reached 2–3% as muscles were developing maximum isometric force. When running at 2 m/s, the soleus muscle consumed less metabolic power at high tendon compliance because the strain of the tendon allowed the muscle fibers to operate nearly isometrically during stance. In contrast, the medial and lateral gastrocnemii consumed less metabolic power at low tendon compliance because less compliant tendons allowed the muscle fibers to operate closer to their optimal lengths during stance. The software and simulations used in this study are freely available at simtk.org and enable examination of muscle energetics with unprecedented detail.  相似文献   

16.
The purpose of the present study was to investigate whether the mechanical properties (i.e. force strain relationship) of the triceps surae tendon and aponeurosis relate to the performed sport activity in an intensity-dependent manner. This was done by comparing sprinters with endurance runners and subjects not active in sports. Sixty-six young male subjects (26+/-5 yr; 183+/-6 cm; 77.6+/-6.7 kg) participated in the study. Ten of these subjects were adults not active in sports, 28 were endurance runners and 28 sprinters. All subjects performed isometric maximal voluntary plantar flexion contractions (MVC) on a dynamometer. The distal aponeuroses of the gastrocnemius medialis (GM) was visualised by ultrasound during the MVC. The results showed that only the sprinters had higher normalised stiffness (relationship between tendon force and tendon strain) of the triceps surae tendon and aponeurosis and maximal calculated tendon forces than the endurance runners and the subjects not active in sports. Furthermore, including the data of all 66 examined participants tendon stiffness correlated significantly (r=0.817, P<0.001) with the maximal tendon force achieved during the MVC. It has been concluded that the mechanical properties of the triceps surae tendon and aponeurosis do not show a graded response to the intensity of the performed sport activity but rather remain at control level in a wide range of applied strains and that strain amplitude and/or frequency should exceed a given threshold in order to trigger additional adaptation effects. The results further indicate that subjects with higher muscle strength possibly increase the margin of tolerated mechanical loading of the tendon due to the greater stiffness of their triceps surae tendon and aponeurosis.  相似文献   

17.
《Journal of biomechanics》2014,47(16):3794-3798
Tendons are able to transmit high loads efficiently due to their finely optimized hierarchical collagen structure. Two mechanisms by which tendons respond to load are collagen fibril sliding and deformation (stretch). Although many studies have demonstrated that regional variations in tendon structure, composition, and organization contribute to the full tendon׳s mechanical response, the location-dependent response to loading at the fibril level has not been investigated. In addition, the instantaneous response of fibrils to loading, which is clinically relevant for repetitive stretch or fatigue injuries, has also not been studied. Therefore, the purpose of this study was to quantify the instantaneous response of collagen fibrils throughout a mechanical loading protocol, both in the insertion site and in the midsubstance of the mouse supraspinatus tendon. Utilizing a novel atomic force microscopy-based imaging technique, tendons at various strain levels were directly visualized and analyzed for changes in fibril d-period with increasing tendon strain. At the insertion site, d-period significantly increased from 0% to 1% tendon strain, increased again from 3% to 5% strain, and decreased after 5% strain. At the midsubstance, d-period increased from 0% to 1% strain and then decreased after 7% strain. In addition, fibril d-period heterogeneity (fibril sliding) was present, primarily at 3% strain with a large majority occurring in the tendon midsubstance. This study builds upon previous work by adding information on the instantaneous and regional-dependent fibrillar response to mechanical loading and presents data proposing that collagen fibril sliding and stretch are directly related to tissue organization and function.  相似文献   

18.
The purpose of the current study in combination with our previous published data (Arampatzis et al., 2007) was to examine the effects of a controlled modulation of strain magnitude and strain frequency applied to the Achilles tendon on the plasticity of tendon mechanical and morphological properties. Eleven male adults (23.9±2.2 yr) participated in the study. The participants exercised one leg at low magnitude tendon strain (2.97±0.47%), and the other leg at high tendon strain magnitude (4.72±1.08%) of similar frequency (0.5 Hz, 1 s loading, 1 s relaxation) and exercise volume (integral of the plantar flexion moment over time) for 14 weeks, 4 days per week, 5 sets per session. The exercise volume was similar to the intervention of our earlier study (0.17 Hz frequency; 3 s loading, 3 s relaxation) allowing a direct comparison of the results. Before and after the intervention ankle joint moment has been measured by a dynamometer, tendon–aponeurosis elongation by ultrasound and cross-sectional area of the Achilles tendon by magnet resonance images (MRI). We found a decrease in strain at a given tendon force, an increase in tendon–aponeurosis stiffness and tendon elastic modulus of the Achilles tendon only in the leg exercised at high strain magnitude. The cross-sectional area (CSA) of the Achilles tendon did not show any statistically significant (P>0.05) differences to the pre-exercise values in both legs. The results indicate a superior improvement in tendon properties (stiffness, elastic modulus and CSA) at the low frequency (0.17 Hz) compared to the high strain frequency (0.5 Hz) protocol. These findings provide evidence that the strain magnitude applied to the Achilles tendon should exceed the value, which occurs during habitual activities to trigger adaptational effects and that higher tendon strain duration per contraction leads to superior tendon adaptational responses.  相似文献   

19.
The importance of fluid-flow-induced shear stress and matrix-induced cell deformation in transmitting the global tendon load into a cellular mechanotransduction response is yet to be determined. A multiscale computational tendon model composed of both matrix and fluid phases was created to examine how global tendon loading may affect fluid-flow-induced shear stresses and membrane strains at the cellular level. The model was then used to develop a quantitative experiment to help understand the roles of membrane strains and fluid-induced shear stresses on the biological response of individual cells. The model was able to predict the global response of tendon to applied strain (stress, fluid exudation), as well as the associated cellular response of increased fluid-flow-induced shear stress with strain rate and matrix-induced cell deformation with strain amplitude. The model analysis, combined with the experimental results, demonstrated that both strain rate and strain amplitude are able to independently alter rat interstitial collagenase gene expression through increases in fluid-flow-induced shear stress and matrix-induced cell deformation, respectively.  相似文献   

20.
Denervation or inactivity is known to decrease the mass and alter the phenotype of muscle. The mechanical response of tendon to inactivity that has been determined experimentally differs from what is reported by patients. We investigated the hypothesis that this difference was the result of artifacts of the testing process and did not represent what occurred in vivo. To test this hypothesis, a novel approach was used to determine the mechanical properties of the tibialis anterior (TA) tendon by optically measuring the end-to-end mechanical strains as well as the local strains at specific regions of excised TA tendon units. When the end-to-end strain of normal TA tendon is determined, stress-strain response curves show considerably more extensibility than when strain is measured across only the midsection of the tendon (mid-tendon). The strain experienced by the region close to the muscle (muscle tendon) is five times greater than the strain in either the mid-tendon or near the bone (bone-tendon). Five weeks of denervation decreased muscle mass by 67%; increased tendon mass by 10%; and changed the entire shape of the nonlinear response curve, including a loss in regional variation in strain, a 3.9-fold increase in end-to-end tangent modulus, and a 70% reduction in the toe region, as a result of a drastic reduction of the extensibility in the muscle-tendon region. The stress-strain response in the mid-tendon region of a normal TA tendon is therefore not indicative of its overall ability to deform in vivo as it transmits forces from muscle to bone.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号