首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Active mobilization of repaired flexor tendons requires sufficient suture strength. This study was designed to investigate the suitability of four newly developed and comparatively strong tendon sutures for flexor tendon repair with active digital mobilization. Fifty fresh flexor digitorum profundus tendons were randomly assigned to five groups and repaired using the Tang, cruciate, Robertson, Silfverskiold, and modified Kessler suture methods. The repaired tendons were subjected to mechanical testing in an Instron tensile machine to determine the 2-mm gap formation force, ultimate strength, elastic modulus, and energy to failure of the sutures. The 2-mm gap formation forces of the sutures were 43.0 N for the Tang, 37.4 N for the cruciate, 25.0 N for the Robertson, 32.3 N for the Silfverskiold, and 21.2 N for the modified Kessler methods. The ultimate strength of the sutures was 53.6 N for the Tang, 46.3 N for the cruciate, 41.6 N for the Robertson, 41.0 N for the Silfverskiold, and 24.7 N for the modified Kessler methods. Statistically, the gap formation force and ultimate strength were the highest in the Tang, higher in the cruciate, and the lowest for the Robertson and the modified Kessler methods. The elastic modulus of the repaired tendons, as represented by the linear slope of the force-displacement curve, was also statistically the largest in the Tang, larger in the cruciate, and lowest for the Robertson and modified Kessler methods. Energy to failure was statistically the largest in the Tang, higher in the cruciate, lower in the Silfverskiold and the Robertson, and the lowest for the modified Kessler methods. It was concluded that significant differences exist in mechanical properties of the newly developed tendon suture methods. Among the methods for tendon repair that were tested, the Tang and the cruciate sutures were the best candidates for flexor tendon repair in the hand with postoperative active mobilization because of their superior tensile strength, elastic properties, energy to failure, and reasonable operation time.  相似文献   

2.
The mechanical properties of turkey and heron leg tendons have been investigated in dynamic tensile tests. Heron tendons have properties similar to those found for various mammalian tendons. The Young's modulus and the density of turkey tendons increase with increasing calcification. Ultimate tensile stresses are similar to those found for uncalcified tendon, but Young's modulus may reach about 16 GPa, a value normally associated with bone. Calcification lowers the amount of strain energy that can be stored temporarily in the tendons of the legs. The contribution made by elastic strain energy storage to lowering the cost of running is reduced.  相似文献   

3.
The purpose of this study was to evaluate maximal torque of the knee flexors and extensors, flexor/extensor ratios, and maximal torque differences between the 2 lower extremities in young track and field athletes. Forty male track and field athletes 13-17 years old and 20 male nonathletes of the same age participated in the study. Athletes were divided into 4 groups according to their age and event (12 runners and 10 jumpers 13-15 years old, 12 runners and 6 jumpers 16-17 years old) and nonathletes into 2 groups of the same age. Maximal torque evaluation of knee flexors and extensors was performed on an isokinetic dynamometer at 60°·s(-1). At the age of 16-17 years, jumpers exhibited higher strength values at extension than did runners and nonathletes, whereas at the age of 13-15 years, no significant differences were found between events. Younger athletes were weaker than older athletes at flexion. Runners and jumpers were stronger than nonathletes in all relative peak torque parameters. Nonathletes exhibited a higher flexor/extensor ratio compared with runners and jumpers. Strength imbalance in athletes was found between the 2 lower extremities in knee flexors and extensors and also at flexor/extensor ratio of the same extremity. Young track and field athletes exhibit strength imbalances that could reduce their athletic performance, and specific strength training for the weak extremity may be needed.  相似文献   

4.
Mammalian terrestrial locomotion has many unifying principles. However, the Macropodoidea are a particularly interesting group that exhibit a number of significant deviations from the principles that seem to apply to other mammals. While the properties of materials that comprise the musculoskeletal system of mammals are similar, evidence suggests that tendon properties in macropodoid marsupials may be size or function dependent, in contrast to the situation in placental mammals. Postural differences related to hopping versus running have a dramatic effect on the scaling of the pelvic limb musculoskeletal system. Ratios of muscle fibre to tendon cross-sectional areas for ankle extensors and digital flexors scale with positive allometry in all mammals, but exponents are significantly higher in macropods. Tendon safety factors decline with increasing body mass in mammals, with eutherians at risk of ankle extensor tendon rupture at a body mass of about 150 kg, whereas kangaroos encounter similar problems at a body mass of approximately 35 kg. Tendon strength appears to limit locomotor performance in these animals. Elastic strain energy storage in tendons is mass dependent in all mammals, but exponents are significantly larger in macropodid. Tibial stresses may scale with positive allometry in kangaroos, which result in lower bone safety factors in macropods compared to eutherian mammals.  相似文献   

5.
6.
ABSTRACT: Bryanton, MA, Kennedy, MD, Carey, JP, and Chiu, LZF. Effect of squat depth and barbell load on relative muscular effort in squatting. J Strength Cond Res 26(10): 2820-2828, 2012-Resistance training is used to develop muscular strength and hypertrophy. Large muscle forces, in relation to the muscle's maximum force-generating ability, are required to elicit these adaptations. Previous biomechanical analyses of multi-joint resistance exercises provide estimates of muscle force but not relative muscular effort (RME). The purpose of this investigation was to determine the RME during the squat exercise. Specifically, the effects of barbell load and squat depth on hip extensor, knee extensor, and ankle plantar flexor RME were examined. Ten strength-trained women performed squats (50-90% 1 repetition maximum) in a motion analysis laboratory to determine hip extensor, knee extensor, and ankle plantar flexor net joint moment (NJM). Maximum isometric strength in relation to joint angle for these muscle groups was also determined. Relative muscular effect was determined as the ratio of NJM to maximum voluntary torque matched for joint angle. Barbell load and squat depth had significant interaction effects on hip extensor, knee extensor, and ankle plantar flexor RME (p < 0.05). Knee extensor RME increased with greater squat depth but not barbell load, whereas the opposite was found for the ankle plantar flexors. Both greater squat depth and barbell load increased hip extensor RME. These data suggest that training for the knee extensors can be performed with low relative intensities but require a deep squat depth. Heavier barbell loads are required to train the hip extensors and ankle plantar flexors. In designing resistance training programs with multi-joint exercises, how external factors influence RME of different muscle groups should be considered to meet training objectives.  相似文献   

7.
Tendons in different locations function in unique, and at times complex, invivo loading environments. Specifically, some tendons are subjected to compression, shear and/or torsion in addition to tensile loading, which play an important role in regulating tendon properties. To date, there have been few studies evaluating tendon mechanics when loaded in compression and shear, which are particularly relevant for understanding tendon regions that experience such non-tensile loading during normal physiologic function. The objective of this study was to evaluate mechanical responses of different regions of bovine deep digital flexor tendons (DDFT) under compressive and shear loading, and correlate structural characteristics to functional mechanical properties. Distal and proximal regions of DDFT were evaluated in a custom-made loading system via three-step incremental stress-relaxation tests. A two-relaxation-time solid linear model was used to describe the viscoelastic response. Results showed large differences in the elastic behavior between regions: distal region stresses were 4–5 times larger than proximal region stresses during compression and 2–3 times larger during shear. Surprisingly, the viscous (i.e., relaxation) behavior was not different between regions for either compression or shear. Histological analysis showed that collagen and proteoglycan in the distal region distributed differently from the proximal region. Results demonstrate mechanical differences between two regions of DDFT under compression and shear loading, which are attributed to variations of composition and microstructural organization. These findings deepen our understanding of structure–function relationships of tendon, particularly for tissues adapted to supporting combinations of tension, compression, and shear in physiological loading environments.  相似文献   

8.
This investigation assessed strength of the hip extensors and flexors when assistive devices and weight bearing are changing after total hip arthroplasty (THA). Eleven individuals (6 men, 5 women; mean age 74.45 +/- 4.88 years) with unilateral THA were evaluated isokinetically at 60 degrees x sec(-1) before surgery on the involved and uninvolved limbs. Each subject's involved limb was tested 60 days after surgery. Comparisons were made between involved and uninvolved limbs and between the involved limb before surgery and 60 days after surgery for both the hip extensors and flexors. Hip extensor and flexor strength before surgery on the involved side was 39% and 29% lower, respectively, compared with the uninvolved side. Sixty days after surgery, strength of the hip extensors and flexors improved 50% and 27%, respectively, compared with before surgery. Over the 60-day interval, the responsiveness of isokinetic testing was high for both muscle groups (range, 0.74-1.51). It would seem appropriate that intensive rehabilitation continue through at least the 60-day period and that isokinetic testing is an effective tool to monitor hip strength before and after surgery.  相似文献   

9.
Two of the forearm flexors of the horse, the superficial and deep digital flexor muscles, are critical to support the digital and fetlock joints, exhibit differing insertions, and are passively supported by the proximal and distal check ligaments, respectively. These two muscles differ in histochemical composition and architecture. The differences are correlated with the different stress levels transmitted through their tendons, and the different frequencies of clinical breakdown that have been reported. Both muscles contain type I and type IIa fibers. A few type IIb fibers occurred in the deep digital flexor. The superficial digital flexor contained approximately 56% type I fibers, extremely short muscle fibers, and extensive connective tissue investment. In contrast, the deep digital flexor had three muscle heads: ulnar, radial, and "long" and "short" regions of the humeral head. The "long" and "short" regions of the humeral head contained 33% and 44% type I fibers, respectively, fiber lengths three to four times as long as those in the superficial digital flexor, and relatively less connective tissue investment. Flexor carpi radialis and flexor carpi ulnaris compared most closely with the humeral head of the deep digital flexor. These data suggest a correlation of the unique architecture of superficial digital flexor with its proposed elastic storage properties during locomotion in horses, and an explanation for the frequent breakdown of the superficial digital flexor in athletic horses.  相似文献   

10.
Moshelion M  Moran N 《Plant physiology》2001,125(2):1142-1150
Leaflet movements in the mimosa-family tree Samanea saman stem from coordinated volume changes of cells in the leaf motor organs in the adaxial and abaxial motor cells ("flexors" and "extensors"). Shrinking, initiated by dissimilar light signals in extensors and in flexors, depends in both cell types on K(+) efflux via depolarization-dependent potassium (K(D)) channels. To compare between flexor and extensor K(D) channels and to test for a possible interaction of these channels with the Ca(2+)-mobilizing phosphoinositide cascade evoked in these motor cells by the "shrinking signals," we probed the channels with varying (5 nM-3 mM) cytosolic free-Ca(2+) concentration ([Ca(2+)](cyt)) in patch-clamped inside-out excised membrane patches. Ca(2+) was not required for K(D) channel activation. [Ca(2+)](cyt) of 600 nM decreased the mean number of open K(D) channels in flexors, as monitored at -30 mV. Detailed analysis revealed that in flexors millimolar [Ca(2+)](cyt) decreased the maximum number of open channels, but simultaneously increased K(D) channel opening probability by negatively shifting the half-maximum-activation voltage by 40 to 50 mV. Thus, the promoting and the inhibitory effects at millimolar [Ca(2+)](cyt) practically cancelled-out. In contrast to flexors, none of the gating parameters of the extensor K(D) channels were affected by [Ca(2+)](cyt). Irrespective of [Ca(2+)](cyt), the steady-state gating of extensor K(D) channels was slightly but significantly more voltage sensitive than that of flexors. The unitary conductances of flexor and extensor K(D) channels were similar and decreased by approximately 20% at millimolar [Ca(2+)](cyt). It is intriguing that the extensor K(D) channels were significantly less K(+) selective than those in flexors.  相似文献   

11.
Leaflet movements in the mimosa-family tree Samanea saman stem from coordinated volume changes of cells in the leaf motor organs in the adaxial and abaxial motor cells ("flexors" and "extensors"). Shrinking, initiated by dissimilar light signals in extensors and in flexors, depends in both cell types on K(+) efflux via depolarization-dependent potassium (K(D)) channels. To compare between flexor and extensor K(D) channels and to test for a possible interaction of these channels with the Ca(2+)-mobilizing phosphoinositide cascade evoked in these motor cells by the "shrinking signals," we probed the channels with varying (5 nM-3 mM) cytosolic free-Ca(2+) concentration ([Ca(2+)](cyt)) in patch-clamped inside-out excised membrane patches. Ca(2+) was not required for K(D) channel activation. [Ca(2+)](cyt) of 600 nM decreased the mean number of open K(D) channels in flexors, as monitored at -30 mV. Detailed analysis revealed that in flexors millimolar [Ca(2+)](cyt) decreased the maximum number of open channels, but simultaneously increased K(D) channel opening probability by negatively shifting the half-maximum-activation voltage by 40 to 50 mV. Thus, the promoting and the inhibitory effects at millimolar [Ca(2+)](cyt) practically cancelled-out. In contrast to flexors, none of the gating parameters of the extensor K(D) channels were affected by [Ca(2+)](cyt). Irrespective of [Ca(2+)](cyt), the steady-state gating of extensor K(D) channels was slightly but significantly more voltage sensitive than that of flexors. The unitary conductances of flexor and extensor K(D) channels were similar and decreased by approximately 20% at millimolar [Ca(2+)](cyt). It is intriguing that the extensor K(D) channels were significantly less K(+) selective than those in flexors.  相似文献   

12.
We examined the temporal changes of isokinetic strength performance of knee flexor (KF) and extensor (KE) strength after a football match. Players were randomly assigned to a control (N = 14, participated only in measurements and practices) or an experimental group (N = 20, participated also in a football match). Participants trained daily during the two days after the match. Match and training overload was monitored with GPS devices. Venous blood was sampled and muscle damage was assessed pre-match, post-match and at 12h, 36h and 60h post-match. Isometric strength as well as eccentric and concentric peak torque of knee flexors and extensors in both limbs (dominant and non-dominant) were measured on an isokinetic dynamometer at baseline and at 12h, 36h and 60h after the match. Functional (KFecc/KEcon) and conventional (KFcon/KEcon) ratios were then calculated. Only eccentric peak torque of knee flexors declined at 60h after the match in the control group. In the experimental group: a) isometric strength of knee extensors and knee flexors declined (P<0.05) at 12h (both limbs) and 36h (dominant limb only), b) eccentric and concentric peak torque of knee extensors and flexors declined (P<0.05) in both limbs for 36h at 60°/s and for 60h at 180°/s with eccentric peak torque of knee flexors demonstrating a greater (P<0.05) reduction than concentric peak torque, c) strength deterioration was greater (P<0.05) at 180°/s and in dominant limb, d) the functional ratio was more sensitive to match-induced fatigue demonstrating a more prolonged decline. Discriminant and regression analysis revealed that strength deterioration and recovery may be related to the amount of eccentric actions performed during the match and athletes'' football-specific conditioning. Our data suggest that recovery kinetics of knee flexor and extensor strength after a football match demonstrate strength, limb and velocity specificity and may depend on match physical overload and players'' physical conditioning level.  相似文献   

13.
This study explores the hypothesis that high-intensity exercise induces degenerative changes in the injury-prone equine superficial digital flexor tendon (SDFT), but not in the rarely injured common digital extensor tendon (CDET). The horse represents a large-animal model that is applicable to human tendon and ligament physiology and pathology. Twelve age-matched female horses undertook galloping exercise three times a week with trotting exercise on alternative days (high-intensity group, n = 6) or only walking exercise (low-intensity group, n = 6) for 18 mo. The SDFT, suspensory ligament, deep digital flexor tendon, and CDET were harvested from the forelimb. Tissue from the mid-metacarpal region of the right limb tendons was analyzed for water, DNA, sulfated glycosaminoglycan and collagen content, collagen type III-to-I ratios, collagen cross-links, and tissue fluorescence. Left limb tendons were mechanically tested to failure. The analyses showed matrix composition to have considerable diversity between the functionally different structures. In addition, the specific structures responded differently to the imposed exercise. High-intensity training resulted in a significant decrease in the GAG content in the SDFT, but no change in collagen content, despite a decrease in collagen fibril diameters. There were no signs of degeneration or change in mechanical properties of the SDFT. The CDET had a lower water content following high-intensity training and a higher elastic modulus. Long-term, high-intensity training in skeletally mature individuals results in changes that suggest accelerated aging in the injury-prone SDFT and adaptation in the CDET.  相似文献   

14.
Matrix metabolism rate differs in functionally distinct tendons.   总被引:1,自引:1,他引:0  
Tendon matrix integrity is vital to ensure adequate mechanical properties for efficient function. Although historically tendon was considered to be relatively inert, recent studies have shown that tendon matrix turnover is active. During normal physiological activities some tendons are subjected to stress and strains much closer to their failure properties than others. Tendons with low safety margins are those which function as energy stores such as the equine superficial digital flexor tendon (SDFT) and human Achilles tendon (AT). We postulate therefore that energy storing tendons suffer a higher degree of micro-damage and thus have a higher rate of matrix turnover than positional tendons. The hypothesis was tested using tissue from the equine SDFT and common digital extensor tendon (CDET). Matrix turnover was assessed indirectly by a combination of measurements for matrix age, markers of degradation, potential for degradation and protein expression. Results show that despite higher cellularity, the SDFT has lower relative levels of mRNA for collagen types I and III. Non-collagenous proteins, although expressed at different levels per cell, do not appear to differ between tendon types. Relative levels of mRNA for MMP1, MMP13 and both pro-MMP3 and MMP13 protein activity were significantly higher in the CDET. Correspondingly levels of cross-linked carboxyterminal telopeptide of type I collagen (ICTP) were higher in the CDET and tissue fluorescence lower suggesting more rapid turnover of the collagenous component. Reduced or inhibited collagen turnover in the SDFT may account for the high level of degeneration and subsequent injury compared to the CDET.  相似文献   

15.
Equine superficial digital flexor tendons (SDFT) are often injured, and they represent an excellent model for human sport tendinopathies. While lesions can be precisely diagnosed by clinical evaluation and ultrasonography, a prognosis is often difficult to establish; the knowledge of the injured tendon's mechanical properties would help in anticipating the outcome. The objectives of the present study were to compare the axial speed of sound (SOS) measured in vivo in normal and injured tendons and to investigate their relationship with the tendons' mechanical parameters, in order to assess the potential of quantitative axial ultrasound to monitor the healing of the injured tendons. SOS was measured in vivo in the right fore SDFTs of 12 horses during walk, before and 3.5 months after the surgical induction of a bilateral core lesion. The 12 horses were then euthanized, their SDFTs isolated and tested in tension to measure their elastic modulus and maximal load (and corresponding stress). SOS significantly decreased from 2179.4 ± 31.4 m/s in normal tendons to 2065.8 ± 67.1 m/s 3.5 months after the surgical induction, and the tendons' elastic modulus (0.90 ± 0.17 GPa) was found lower than what has been reported in normal tendons. While SOS was not correlated to tendon maximal load and corresponding stress, the SOS normalized on its value in normal tendons was correlated to the tendons' elastic modulus. These preliminary results confirm the potential of axial SOS in helping the functional assessment of injured tendon.  相似文献   

16.
Carpal tunnel syndrome is a frequently encountered peripheral nerve disorder caused by mechanical insult to the median nerve, which may in part be a result of impingement by the adjacent digital flexor tendons. Realistic finite element (FE) analysis to determine contact stresses between the flexor tendons and median nerve depends upon the use of physiologically accurate material properties. To assess the transverse compressive properties of the digital flexor tendons and median nerve, these tissues from ten cadaveric forearm specimens were compressed transversely while under axial load. The experimental compression data were used in conjunction with an FE-based optimization routine to determine apparent hyperelastic coefficients (μ and α) for a first-order Ogden material property definition. The mean coefficient pairs were μ=35.3 kPa, α=8.5 for the superficial tendons, μ=39.4 kPa, α=9.2 for the deep tendons, μ=24.9 kPa, α=10.9 for the flexor pollicis longus (FPL) tendon, and μ=12.9 kPa, α=6.5 for the median nerve. These mean Ogden coefficients indicate that the FPL tendon was more compliant at low strains than either the deep or superficial flexor tendons, and that there was no significant difference between superficial and deep flexor tendon compressive behavior. The median nerve was significantly more compliant than any of the flexor tendons. The material properties determined in this study can be used to better understand the functional mechanics of the carpal tunnel soft tissues and possible mechanisms of median nerve compressive insult, which may lead to the onset of carpal tunnel syndrome.  相似文献   

17.
Growth-related changes in the mechanical properties of collagen fascicles (approximately 300 microm in diameter) were studied using patellar tendons obtained from skeletally immature 1 and 2 months old and matured 6 months old rabbits. Tensile properties were determined using a specially designed micro-tensile tester. In each age group, there were no significant differences in the properties among cross-sectional locations in the tendon. Tangent modulus and tensile strength significantly increased with age; the rates of their increases between 1 and 2 months were higher than those between 2 and 6 months. The tangent modulus and tensile strength were positively correlated with the body weight of animals. However, growth-related changes in the mechanical properties were different between collagen fascicles and bulk patellar tendons, which may be attributable to such non-collagenous components as ground substances and also to mechanical interactions between collagen fascicles.  相似文献   

18.

Objective

The aim of the study was to: 1) evaluate the differences in pre-post operative knee functioning, mechanical stability, isokinetic knee muscle strength in simultaneous arthroscopic patients after having undergone an anterior cruciate ligament (ACL) and the posterior cruciate ligament (PCL) with hamstring tendons reconstruction, 2) compare the results of ACL/PCL patients with the control group.

Design

Controlled Laboratory Study.

Materials and Methods

Results of 11 ACL/PCL patients had been matched with 22 uninjured control participants (CP). Prior to surgery, and minimum 2 years after it, functional assessment (Lysholm and IKDC 2000), mechanical knee joint stability evaluation (Lachman and “drawer” test) and isokinetic tests (bilateral knee muscle examination) had been performed. Different rehabilitation exercises had been used: isometric, passive exercises, exercises increasing the range of motion and proprioception, strength exercises and specific functional exercises.

Results

After arthroscopy no significant differences had been found between the injured and uninjured leg in all isokinetic parameters in ACL/PCL patients. However, ACL/PCL patients had still shown significantly lower values of strength in relative isokinetic knee flexors (p = 0.0065) and extensors (p = 0.0171) compared to the CP. There were no differences between groups regarding absolute isokinetic strength and flexors/extensors ratio. There was statistically significant progress in IKDC 2000 (p = 0.0044) and Lysholm (p = 0.0044) scales prior to (44 and 60 points respectively) and after the reconstruction (61 for IKDC 2000 and 94 points for Lysholm).

Conclusions

Although harvesting tendons of semitendinosus and/or gracilis from the healthy extremity diminishes muscle strength of knee flexors in comparison to the CP, flexor strength had improved. Statistically significant improvement of the knee extensor function may indicate that the recreation of joint mechanical stability is required for restoring normal muscle strength. Without restoring normal muscle function and strength, surgical intervention alone may not be sufficient enough to ensure expected improvement of the articular function.  相似文献   

19.
The collagenous dermis of the white rhinoceros forms a thick, protective armour that is highly specialized in its structure and material properties compared with other mammalian skin. Rhinoceros skin is three times thicker than predicted allometrically, and it contains a dense and highly ordered three-dimensional array of relatively straight and highly crosslinked collagen fibres. The skin of the back and flanks exhibits a steep stress-strain curve with very little 'toe' region, a high elastic modulus (240 MPa), a high tensile strength (30 MPa), a low breaking strain (0.24) and high breaking energy (3 MJm-3) and work of fracture (78 kJm-2). By comparison, the belly skin is somewhat less stiff, weaker, and more extensible. In compression, rhinoceros skin withstands average stresses and strains of 170 MPa and 0.7, respectively, before yielding. As a biological material, rhinoceros dorsolateral skin has properties that are intermediate between those of 'normal' mammalian skin and tendons. This study shows that the dermal armour of the rhinoceros is very well adapted to resist blows from the horns of conspecifics, as might occur during aggressive behaviour, due to specialized material properties as well as its great thickness.  相似文献   

20.
Repair success for injuries to the flexor tendon in the hand is often limited by the in vivo behaviour of the suture used for repair. Common problems associated with the choice of suture material include increased risk of infection, foreign body reactions, and inappropriate mechanical responses, particularly decreases in mechanical properties over time. Improved suture materials are therefore needed. As high-performance materials with excellent tensile strength, spider silk fibres are an extremely promising candidate for use in surgical sutures. However, the mechanical behaviour of sutures comprised of individual silk fibres braided together has not been thoroughly investigated. In the present study, we characterise the maximum tensile strength, stress, strain, elastic modulus, and fatigue response of silk sutures produced using different braiding methods to investigate the influence of braiding on the tensile properties of the sutures. The mechanical properties of conventional surgical sutures are also characterised to assess whether silk offers any advantages over conventional suture materials. The results demonstrate that braiding single spider silk fibres together produces strong sutures with excellent fatigue behaviour; the braided silk sutures exhibited tensile strengths comparable to those of conventional sutures and no loss of strength over 1000 fatigue cycles. In addition, the braiding technique had a significant influence on the tensile properties of the braided silk sutures. These results suggest that braided spider silk could be suitable for use as sutures in flexor tendon repair, providing similar tensile behaviour and improved fatigue properties compared with conventional suture materials.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号