首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The polymerase chain reaction (PCR) was performed to amplify a 1.0-kilobase (kb) probe-specific region of DNA from the herbicide-degrading bacterium Pseudomonas cepacia AC1100 in order to increase the sensitivity of detecting the organism by dot-blot analysis. The 1.0-kb region was an integral portion of a larger 1.3-kb repeat sequence which is present as 15 to 20 copies on the P. cepacia AC1100 genome. PCR was performed by melting the target DNA, annealing 24-base oligonucleotide primers to unique sequences flanking the 1.0-kb region, and performing extension reactions with DNA polymerase. After extension, the DNA was again melted, and the procedure was repeated for a total of 25 to 30 cycles. After amplification the reaction mixture was transferred to nylon filters and hybridized against radiolabeled 1.0-kb fragment probe DNA. Amplified target DNA was detectable in samples initially containing as little as 0.3 pg of target. The addition of 20 micrograms of nonspecific DNA isolated from sediment samples did not hinder amplification or detection of the target DNA. The detection of 0.3 pg of target DNA was at least a 10(3)-fold increase in the sensitivity of detecting gene sequences compared with dot-blot analysis of nonamplified samples. PCR performed after bacterial DNA was isolated from sediment samples permitted the detection of as few as 100 cells of P. cepacia AC1100 per 100 g of sediment sample against a background of 10(11) diverse nontarget organisms; that is, P. cepacia AC1100 was positively detected at a concentration of 1 cell per g of sediment. This represented a 10(3)-fold increase in sensitivity compared with nonamplified samples.  相似文献   

2.
The polymerase chain reaction (PCR) was performed to amplify a 1.0-kilobase (kb) probe-specific region of DNA from the herbicide-degrading bacterium Pseudomonas cepacia AC1100 in order to increase the sensitivity of detecting the organism by dot-blot analysis. The 1.0-kb region was an integral portion of a larger 1.3-kb repeat sequence which is present as 15 to 20 copies on the P. cepacia AC1100 genome. PCR was performed by melting the target DNA, annealing 24-base oligonucleotide primers to unique sequences flanking the 1.0-kb region, and performing extension reactions with DNA polymerase. After extension, the DNA was again melted, and the procedure was repeated for a total of 25 to 30 cycles. After amplification the reaction mixture was transferred to nylon filters and hybridized against radiolabeled 1.0-kb fragment probe DNA. Amplified target DNA was detectable in samples initially containing as little as 0.3 pg of target. The addition of 20 micrograms of nonspecific DNA isolated from sediment samples did not hinder amplification or detection of the target DNA. The detection of 0.3 pg of target DNA was at least a 10(3)-fold increase in the sensitivity of detecting gene sequences compared with dot-blot analysis of nonamplified samples. PCR performed after bacterial DNA was isolated from sediment samples permitted the detection of as few as 100 cells of P. cepacia AC1100 per 100 g of sediment sample against a background of 10(11) diverse nontarget organisms; that is, P. cepacia AC1100 was positively detected at a concentration of 1 cell per g of sediment. This represented a 10(3)-fold increase in sensitivity compared with nonamplified samples.  相似文献   

3.
Graphene oxide (GO) has proven to be a satisfactory DNA-sensor platform for applications in enzyme-free signal amplification, fluorescence-based amplification, and nanoparticle-based platforms because of its excellent electrical, thermal, and optical properties. In this study, we designed a novel platform for the fluorescence detection of biomolecules, using a fluorescent dye-labeled primer and GO. We applied this system for the detection of the IS6110 insertion sequence of the Mycobacterium tuberculosis complex (MTB) and evaluated its feasibility for use in molecular diagnostics. Fifty-four sputum specimens were collected at our institution from October 2010 to March 2012. To detect MTB in the samples, we performed PCR amplification of the IS6110 DNA sequence using FAM-labeled primers, after which the PCR amplicon was incubated with GO and the fluorescence was measured. The results were compared with those obtained by conventional real-time quantitative PCR (RQ-PCR). The fluorescence intensity observed increased in a concentration-dependent manner with the FAM-labeled IS6110 amplicon. The results of the PCR-GO system for detecting IS6110 DNA were in good agreement with those obtained with conventional RQ-PCR (kappa statistic = 0.925). The PCR-GO system detected MTB DNA in 23 of 25 RQ-PCR-positive sputum samples (92.0%; 95% CI, 75.0–98.0%), but not in 29 of 29 RQ-PCR-negative sputum samples (100%; 95% CI, 88.1–100.0%). These results indicate the utility of the PCR-GO system in molecular diagnostics.  相似文献   

4.
Prompt laboratory diagnosis of leptospirosis infection facilitates patient management and initiation of therapy. A cost effective real-time PCR assay using SYBR Green I was developed for detection of pathogenic leptospires in serum specimens. Specific PCR products were obtained only with DNA of pathogenic Leptospira genomospecies. LightCycler PCR ability to distinguish between species was possible using melting curves, providing an approach for identification with a specific Tm assigned to a single species or set of species. Assay sensitivity was approximately 50 leptospires/ml, corresponding to one to two genome copies in a PCR mixture. Fifty-one patients who had clinical symptoms consistent with leptospirosis were tested both with a previously described rrs amplification and our real-time assay. Our LFB1 real-time assay confirmed the diagnosis for 25 patients (49%, 25/51) and revealed an estimated density of 8.0x10(1)-3.9x10(4) leptospires/ml of blood. The total assay time for 12 clinical samples from sample to data analysis was less than 3 h. These data illustrate the potential of our LFB1 real-time assay for the rapid detection of leptospires in serum samples and their subsequent quantification in a single run.  相似文献   

5.
Isolated-probe PCR (IP-PCR) is a method that combines asymmetric PCR, unlabeled probes, and high-resolution DNA melting while maintaining a closed tube system. A double-stranded DNA (dsDNA) dye LCGreen I was used to detect the unlabeled probes. LCGreen I is also used to detect the 277-base pair PCR product peak as an internal amplification control. To accomplish this, IP-PCR separates the asymmetric PCR amplification step and the detection step of the unlabeled probes. This prevents the probes from interfering with the amplification of the DNA target. The samples are then melted using a high-resolution DNA melting instrument: the HR-1. The closed tube system virtually eliminates PCR product contamination or sample carryover The target apolipoprotein E (APOE) was chosen to test the IP-PCR technique. APOE contains two single nucleotide polymorphisms (SNPs) located 139 base pairs apart in a GC-rich region of the human genome. The results from this study show that the IP-PCR technique was able to determine the correct APOE genotype for each of the 101 samples. The IP-PCR technique should also be useful in detecting SNPs in other high-GC regions of the human genome.  相似文献   

6.
7.
In this paper we describe optimization of SYBR Green I-based real-time PCR parameters and testing of a large number of microbial species with vvh-specific oligonucleotide primers to establish a rapid, specific, and sensitive method for detection of Vibrio vulnificus in oyster tissue homogenate and Gulf of Mexico water (gulf water). Selected oligonucleotide primers for the vvh gene were tested for PCR amplification of a 205-bp DNA fragment with a melting temperature of approximately 87 degrees C for 84 clinical and environmental strains of V. vulnificus. No amplification was observed with other vibrios or nonvibrio strains with these primers. The minimum level of detection by the real-time PCR method was 1 pg of purified genomic DNA or 10(2) V. vulnificus cells in 1 g of unenriched oyster tissue homogenate or 10 ml of gulf water. It was possible to improve the level of detection to one V. vulnificus cell in samples that were enriched for 5 h. The standard curves prepared from the real-time PCR cycle threshold values revealed that there was a strong correlation between the number of cells in unenriched samples and the number of cells in enriched samples. Detection of a single cell of V. vulnificus in 1 g of enriched oyster tissue homogenate is in compliance with the recent Interstate Shellfish Sanitation Conference guidelines. The entire detection method, including sample processing, enrichment, and real-time PCR amplification, was completed within 8 h, making it a rapid single-day assay. Rapid and sensitive detection of V. vulnificus would ensure a steady supply of postharvest treated oysters to consumers, which should help decrease the number of illnesses or outbreaks caused by this pathogen.  相似文献   

8.
Human herpesvirus 5 (HHV-5, formerly known as CMV) is a beta-herpesvirus widely spread within a population. Thus, HHV-5 infections are a serious matter of concern in a group of immunocompromised patients. The goal of the study was modification and optimization of conventional PCR method developed for the detection of HHV-5 DNA to the real-time variant (RTmPCR) and determination of analytical resolution of the modified methods. Thirty plasma samples were tested for the presence of HHV-5 DNA using the LightCycler system with two different methods--one with SYBR Green I fluorochrome method and second one using TaqMan fluorescent probes and a qualitative in-house gel-stained PCR assay using primers that amplify part of HHV-5 MIE gene. The analytical sensitivity of real-time PCR assay was tested using serial dilutions of HHV-5 DNA in range between 10(0) and 10(-6). For comparison typical end-point detected PCR for cytomegalovirus detection with the same DNA dilutions was made. The sensitivity of novel method was about 100-fold higher than older one. Both LightCycler assays detected HHV-5 DNA in 27 samples, also which were negative by the gel-stained PCR. Analysis of the available clinical and serological data associated with these samples suggested that the real-time results in all of these cases were true positive. The conclusion is that real-time PCR methods are more sensitive than the conventional PCR used in this study. The additional sensitivity was valuable for detection of patients with low-copy viremia. The high level of sensitivity, specificity, accuracy, and rapidity provided by the LightCycler instrument are favorable for the use of this system in the detection of HHV-5 DNA in clinical specimens.  相似文献   

9.
The current methods for the detection of pathogenic Yersinia enterocolitica bacteria in food are time consuming and inefficient. Therefore, we have developed and evaluated in-house a TaqMan probe-based real-time PCR method for the detection of this pathogen. The complete method comprises overnight enrichment, DNA extraction, and real-time PCR amplification. Also included in the method is an internal amplification control. The selected primer-probe set was designed to use a 163-bp amplicon from the chromosomally located gene ail (attachment and invasion locus). The selectivity of the PCR method was tested with a diverse range (n = 152) of related and unrelated strains, and no false-negative or false-positive PCR results were obtained. The sensitivity of the PCR amplification was 85 fg purified genomic DNA, equivalent to 10 cells per PCR tube. Following the enrichment of 10 g of various food samples (milk, minced beef, cold-smoked sausage, fish, and carrots), the sensitivity ranged from 0.5 to 55 CFU Y. enterocolitica. Good precision, robustness, and efficiency of the PCR amplification were also established. In addition, the method was tested on naturally contaminated food; in all, 18 out of 125 samples were positive for the ail gene. Since no conventional culture method could be used as a reference method, the PCR products amplified from these samples were positively verified by using conventional PCR and sequencing of the amplicons. A rapid and specific real-time PCR method for the detection of pathogenic Y. enterocolitica bacteria in food, as presented here, provides a superior alternative to the currently available detection methods and makes it possible to identify the foods at risk for Y. enterocolitica contamination.  相似文献   

10.
We have established a SYBR Green-based realtime PCR method using AnyDirect solution, which enhances PCR from whole blood, for direct amplification of the virA gene of Shigella flexneri and the invA gene of Salmonella typhimurium from human feces without prior DNA purification. When we compared the efficiency of conventional or realtime PCR amplification of the virA and invA genes from the supernatant of boiled feces supplemented with S. flexneri and S. typhimurium in the presence or absence of AnyDirect solution, amplification products were detected only in reactions to which AnyDirect solution had been added. The detection limit of real-time PCR was 1 x 10(4) CFU/g feces for S. flexneri and 2 x 10(4) CFU/g feces for S. typhimurium this sensitivity level was comparable to other studies. Our real-time PCR assay with AnyDirect solution is simple, rapid, sensitive, and specific, and allows simultaneous detection of S. flexneri and S. typhimurium directly from fecal samples without prior DNA purification.  相似文献   

11.
In the present study, a robust TaqMan real-time PCR amplifying the F57 and the ISMav2 sequences of Mycobacterium avium subsp. paratuberculosis from bovine fecal samples was developed and validated. The validation was based on the recommendations of International Organization for Standardization protocols for PCR and real-time PCR methods. For specificity testing, 205 bacterial strains were selected, including 105 M. avium subsp. paratuberculosis strains of bovine, ovine, and human origin and 100 non-M. avium subsp. paratuberculosis strains. Diagnostic quality assurance was obtained by use of an internal amplification control. By investigating six TaqMan reagents from different suppliers, the 100% detection probability was assessed to be 0.1 picogram M. avium subsp. paratuberculosis DNA per PCR. The amplification efficiency was 98.2% for the single-copy gene F57 and 97.8% for the three-copy insertion sequence ISMav2. The analytical method was not limited due to instrument specificity. The triplex real-time PCR allowed the reliable detection of M. avium subsp. paratuberculosis DNA using the ABI Prism 7000 sequence detection system, and the LightCycler 1.0. TaqMan(mgb) and locked nucleic acid fluorogenic probes were suitable for fluorescent signal detection. To improve the detection of M. avium subsp. paratuberculosis from bovine fecal samples, a more efficient DNA extraction method was developed, which offers the potential for automated sample processing. The 70% limit of detection was assessed to be 10(2) CFU per gram of spiked bovine feces. Comparative analysis of 108 naturally contaminated samples of unknown M. avium subsp. paratuberculosis status resulted in a relative accuracy of 98.9% and a sensitivity of 94.4% for fecal samples containing <10 CFU/g feces compared to the traditional culture method.  相似文献   

12.
As part of a large international project for standardization of PCR (Food-PCR; www.pcr.dk), a multiplex, multiplatform, ready-to-go enrichment followed by a real-time PCR method, including an internal amplification control, was developed for detection of food-borne thermotolerant campylobacters in chickens. Chicken rinse samples were enriched in Bolton broth for 20 h, a simple and rapid (1-h) resin-based DNA extraction was performed, and DNA samples were then tested with two instrument platforms: ABI-PRISM 7700 and RotorGene 3000. The method was validated against an International Standard Organization (ISO)-based culture method by testing low, medium, and high levels of 12 spiked and 66 unspiked, presumably naturally contaminated, chicken rinse samples. In the RotorGene, a positive PCR response was detected in 40 samples of the 66. This was in complete agreement with the enriched ISO culture. The ABI-PRISM 7700 missed one culture-positive sample. Positive samples contained 10(2) to 10(7) CFU/ml after enrichment in Bolton broth. In the enriched samples a detection probability of 95% was obtained at levels of 1 x 10(3) and 2 x 10(3) CFU/ml in the RotorGene and ABI-PRISM, respectively. The amplification efficiency in both platforms was 90%, although the linear range of amplification of purified genomic DNA was 1.5 x 10(1) to 1 x 10(7) (R(2) = 1.00) for the RotorGene and 10(3) to 10(7) (R(2) = 0.99) for the ABI-PRISM. In RotorGene and ABI-PRISM the levels of precision of detection as determined by standard deviation (coefficients of variation) of 6-carboxyfluorescein (FAM) threshold cycle (Ct) values were 0.184 to 0.417 (0.65 to 2.57%) and 0.119 to 0.421 (0.59 to 1.82%), respectively. The results showed a correlation (R(2)) of 0.94 between the target FAM Ct values and CFU per milliliter of enriched naturally contaminated chicken samples, which indicates PCR's additional potential as a tool for quantitative risk assessment. Signal from the internal amplification control was detected in all culture-negative samples (VIC Ct: 23.1 to 28.1). The method will be taken further and validated in an international collaborative trial with regard to standardization.  相似文献   

13.
14.
 Detection of integrated human papillomavirus type 16 (HPV-16) DNA in SiHa and CaSki cells was used as a model system to demonstrate sensitivity and resolution of a well defined target. Using 293- to 1987-base polymerase chain reaction (PCR)-synthesized probes to the E6 and E7 open reading frames of HPV-16, several fluorescent in situ hybridization (FISH) detection methods, enhanced with tyramide signal amplification (TSA), were compared. The synthetic probes were biotin labeled by a nick translation method and the hybridized probes were detected by various fluorescent TSA methods using cyanine 3 tyramide, biotinyl tyramide and a biotin TSA Plus reagent. High sensitivity detection in SiHa cells was demonstrated using a 619-base probe to detect two single copies of integrated HPV-16 DNA. In CaSki cells, which contain up to 600 copies of HPV-16 DNA, a 293-base probe was used for detection. The results of these comparisons show that with refinement of TSA methods and reagents, increasing levels of high sensitivity detection can be achieved and that these methods allow subnuclear localization as well. Accepted: 20 June 1997  相似文献   

15.
Multiple displacement amplification (MDA) is an isothermal, sequence-independent method for the amplification of high molecular weight DNA that is driven by φ29 DNA polymerase (DNAP). Here we report digital MDA (dMDA), an ultrasensitive method for quantifying nucleic acid fragments of unknown sequence. We use the new assay to show that our custom φ29 DNAP preparation is free of contamination at the limit of detection of the dMDA assay (1 contaminating molecule per assay microliter). Contamination in commercially available preparations is also investigated. The results of the dMDA assay provide strong evidence that the so-called 'template-independent' MDA background can be attributed to high-molecular weight contaminants and is not primer-derived in the commercial kits tested. dMDA is orders of magnitude more sensitive than PCR-based techniques for detection of microbial genomic DNA fragments and opens up new possibilities for the ultrasensitive quantification of DNA fragments in a wide variety of application areas using MDA chemistry and off-the-shelf hardware developed for digital PCR.  相似文献   

16.
In this paper we describe optimization of SYBR Green I-based real-time PCR parameters and testing of a large number of microbial species with vvh-specific oligonucleotide primers to establish a rapid, specific, and sensitive method for detection of Vibrio vulnificus in oyster tissue homogenate and Gulf of Mexico water (gulf water). Selected oligonucleotide primers for the vvh gene were tested for PCR amplification of a 205-bp DNA fragment with a melting temperature of approximately 87°C for 84 clinical and environmental strains of V. vulnificus. No amplification was observed with other vibrios or nonvibrio strains with these primers. The minimum level of detection by the real-time PCR method was 1 pg of purified genomic DNA or 102 V. vulnificus cells in 1 g of unenriched oyster tissue homogenate or 10 ml of gulf water. It was possible to improve the level of detection to one V. vulnificus cell in samples that were enriched for 5 h. The standard curves prepared from the real-time PCR cycle threshold values revealed that there was a strong correlation between the number of cells in unenriched samples and the number of cells in enriched samples. Detection of a single cell of V. vulnificus in 1 g of enriched oyster tissue homogenate is in compliance with the recent Interstate Shellfish Sanitation Conference guidelines. The entire detection method, including sample processing, enrichment, and real-time PCR amplification, was completed within 8 h, making it a rapid single-day assay. Rapid and sensitive detection of V. vulnificus would ensure a steady supply of postharvest treated oysters to consumers, which should help decrease the number of illnesses or outbreaks caused by this pathogen.  相似文献   

17.
18.
The polymerase chain reaction (PCR) can confirm the presence of bacteria, but it is unable to differentiate between live and dead bacteria. Although ethidium monoazide (EMA)- and propidium monoazide (PMA)-based PCR have been evaluated, a quantity of ≥ 10(3)cells/ml dead cells produces a false-positive reading at 40 to 50 cycles (K. Rudi et al., Appl. Environ. Microbiol. 71 (2005) 1018-1024). After confirming the precision of real-time PCR of a long DNA target (16S or 23S ribosomal RNA [rRNA] gene, 1490 or 2840 bp), we evaluated the degree of suppression of an EMA treatment on the 16S/23S PCR using various amplification lengths (110-2840 bp) with heat-killed cells of Enterobacteriaceae (e.g., Salmonella enteritidis). We found that the inhibition rate was proportional to the PCR amplification length; short DNA (110 bp) amplification slightly delayed the threshold cycle (C(T)) of heat-killed cells of Enterobacteriaceae when compared with no EMA treatment. Regardless of the amplification length, the C(T) delay using live cells of Enterobacteriaceae with EMA was negligible. Thus, our real-time PCR of a long DNA (16S or 23S) template following EMA treatment is a rapid viable bacterial assay, which can potentially target all genera, for testing pasteurized milk that may have originally been contaminated with high levels of dead bacteria.  相似文献   

19.
A novel method, which involves a nested PCR in a single closed tube, was developed for the sensitive detection of Erwinia amylovora in plant material. The external and internal primer pairs used had different annealing temperatures and directed the amplification of a specific DNA fragment from plasmid pEA29. The procedure involved two consecutive PCRs, the first of which was performed at a higher annealing temperature that allowed amplification only by the external primer pair. Using pure cultures of E. amylovora, the sensitivity of the nested PCR in one tube was similar to that of a standard nested PCR in two tubes. The specificity and sensitivity were greater than those of standard PCR procedures that used a single primer pair. The presence of inhibitors in plant material, very common in E. amylovora hosts, is overcome with this system in combination with a simple DNA extraction protocol because it eliminates many of the inhibitory compounds. In addition, it needs a very small sample volume (1 microl of DNA extracted). With 83 samples of naturally infected material, this method achieved better results than any other PCR technique: standard PCR detected 55% of positive samples, two-tube nested PCR detected 71% of positive samples, and nested PCR in a single closed tube detected 78% of positive samples. When analyzing asymptomatic plant material, the number of positive samples detected by the developed nested PCR was also the highest, compared with the PCR protocols indicated previously (17, 20, and 25% of 251 samples analyzed, respectively). This method is proposed for the detection of endophytic and epiphytic populations of E. amylovora in epidemiological studies and for routine use in quarantine surveys, due to its high sensitivity, specificity, speed, and simplicity.  相似文献   

20.
Rapid microbiological methods (RMMs) as an alternative to conventional cultivation-based bioburden analysis are receiving increasing attention although no single technology is currently able to satisfy the needs of the health care industry. Among the RMMs, quantitative PCR (qPCR) seems particularly suited. Its implementation is, however, hampered by false-positive signals originating from free DNA in PCR reagents or from dead cells in the samples to be analysed. In this study, we assessed the capability of propidium monoazide (PMA) to inactivate exogenous DNA in PCR reagents and thus to minimise its impact in bioburden analysis. PMA is a membrane-impermeant dye that intercalates into DNA and covalently binds to it upon photoactivation leading to strong inhibition of PCR amplification. PMA is currently used mainly for treatment of microbiological samples to exclude signals from membrane-compromised cells, but is also very useful for suppression of exogenous DNA signals. In addition to testing the effect of different PMA concentrations on non-template controls and target DNA, we demonstrate the effect of amplicon length on the exclusion of background amplification. Targeting a 1,108-bp 16S rRNA gene fragment using universal bacterial primers and PCR reagents treated with 5 μM PMA resulted in complete suppression of signals from exogenous DNA within 50 cycles of amplification, while a limit of detection of 10 copies of Escherichia coli genomic DNA per PCR reaction was achieved. A combined PMA treatment of sample and PCR reagents furthermore improved the selective detection of live cells making this method appear a highly attractive RMM.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号