共查询到20条相似文献,搜索用时 0 毫秒
1.
Dong Li Zheng Li Jianwei Yu Nan Cao Ruyin Liu Min Yang 《Applied and environmental microbiology》2010,76(21):7171-7180
The role of bacteria in the occasional emergence of red water, which has been documented worldwide, has yet to be determined. To better understand the mechanisms that drive occurrences of red water, the bacterial community composition and the relative abundance of several functional bacterial groups in a water distribution system of Beijing during a large-scale red water event were determined using several molecular methods. Individual clone libraries of the 16S rRNA gene were constructed for three red water samples and one sample of normal water. Beta-, Alpha-, and Gammaproteobacteria comprised the major bacterial communities in both red water and normal water samples, in agreement with previous reports. A high percentage of red water clones (25.2 to 57.1%) were affiliated with or closely related to a diverse array of iron-oxidizing bacteria, including the neutrophilic microaerobic genera Gallionella and Sideroxydans, the acidophilic species Acidothiobacillus ferrooxidans, and the anaerobic denitrifying Thermomonas bacteria. The genus Gallionella comprised 18.7 to 28.6% of all clones in the three red water libraries. Quantitative real-time PCR analysis showed that the 16S rRNA gene copy concentration of Gallionella spp. was between (4.1 ± 0.9) × 107 (mean ± standard deviation) and (1.6 ± 0.3) × 108 per liter in red water, accounting for 13.1% ± 2.9% to 17.2% ± 3.6% of the total Bacteria spp. in these samples. By comparison, the percentages of Gallionella spp. in the normal water samples were 0.1% or lower (below the limit of detection), suggesting an important role of Gallionella spp. in the formation of red water.On occasion, extensive precipitation of iron oxides in drinking water distribution systems manifests as red water at the tap and results in serious deterioration of water quality, with undesirable esthetic and health effects (18, 40, 46). The abundance of ferrous iron in source water or the acceleration of corrosion of iron pipelines after the loosening of chemical and microbial films from the interior surfaces of distribution systems might be the sources of iron oxides in red water. Switching of water sources has been observed to be associated with red water due to disruption of the delicate chemical equilibrium in water supply systems (18). High concentrations of anions, particularly sulfate ions, have been recognized as a causative agent of red water in many cases, reflected in high values on indices such as the Larson-Skold index (18, 29). Other physicochemical factors, such as insufficient disinfection residue, extended hydraulic retention time, low levels of dissolved oxygen, high temperature, low alkalinity, and high chloride concentration, have also been implicated in the emergence of red water (18, 46).In addition to physicochemical factors, microorganisms may also participate in the unique phenomenon of red water. Drinking water distribution systems are a unique niche for microorganisms, despite oligotrophic conditions and the presence of free or combined chlorine (3, 18). Phylogenetically diverse bacterial groups can inhabit the bulk water or biofilms attached to pipes. Culture-based and independent analyses have revealed that members of the class Proteobacteria, including the Alpha-, Beta-, and Gammaproteobacteria, are typically the most abundant bacterial group in water distribution systems, followed by bacterial phyla such as Actinobacteria, Firmicutes, and Bacteroidetes (13, 38). Bacteria inhabiting distribution systems mainly fill functions of diverse carbon source utilization and nitrification, as well as microbial corrosion (3). Meanwhile, during periods of red water, abundant ferrous iron in the bulk water creates favorable conditions for the growth of bacteria in the distribution systems, as this iron scavenges residual chlorine and serves as an energy source for iron-oxidizing bacteria. Some neutrophilic iron oxidizers, such as Gallionella spp. and Leptothrix ochracea, which have occasionally been observed in association with red water events because of their distinct morphology, can promote the precipitation of iron oxides by converting ferrous iron to ferric iron (9, 46). As very little energy can be generated during the oxidation of ferrous to ferric iron, a large quantity of iron needs to be oxidized to support the growth of lithotrophic iron oxidizers. It has been calculated that the ratio of iron to the weight of bacterial cell material could be up to approximately 450 to 500, assuming that the oxidation of ferrous iron provides the sole energy for the synthesis of cell material (9). Emerson et al. have found that the oxidation rate of ferrous iron could be up to 600 to 960 nmol per h per cm3 of mat material that contained up to 109 bacterial cells, most of which were iron oxidizers like Gallionella spp. and Leptothrix ochracea, and the oxidation rate of ferrous iron by iron oxidizers could be as high as four times that of dissolved oxygen (15). These neutrophilic iron oxidizers have been even utilized to remove iron from groundwater by passage of preaerated water through sand filters during drinking water treatment (24, 36). Thus, iron-oxidizing species might play an important role in red water events. With the exception of specific neutrophilic iron oxidizers (e.g., Gallionella spp. and Leptothrix ochracea), the whole microbial community composition in red water and the presence of potentially functional groups, including neutrophilic iron-oxidizing bacteria in red water, is poorly defined, possibly because the appearance of this unique phenomenon in real distribution systems is so irregular. To better understand the mechanisms that drive the emergence of red water, the bacterial community composition and the relative abundance of several functional bacterial groups in a water distribution system of Beijing during a large-scale red water event were determined using several molecular methods. The results of this comprehensive investigation of the biological component of red water will provide valuable information for those managing red water events in water distribution systems. 相似文献
2.
Identification of Bacteria in Biofilm and Bulk Water Samples from a Nonchlorinated Model Drinking Water Distribution System: Detection of a Large Nitrite-Oxidizing Population Associated with Nitrospira spp. 下载免费PDF全文
Adam C. Martiny Hans-Jrgen Albrechtsen Erik Arvin Sren Molin 《Applied microbiology》2005,71(12):8611-8617
In a model drinking water distribution system characterized by a low assimilable organic carbon content (<10 μg/liter) and no disinfection, the bacterial community was identified by a phylogenetic analysis of rRNA genes amplified from directly extracted DNA and colonies formed on R2A plates. Biofilms of defined periods of age (14 days to 3 years) and bulk water samples were investigated. Culturable bacteria were associated with Proteobacteria and Bacteriodetes, whereas independently of cultivation, bacteria from 12 phyla were detected in this system. These included Acidobacteria, Nitrospirae, Planctomycetes, and Verrucomicrobia, some of which have never been identified in drinking water previously. A cluster analysis of the population profiles from the individual samples divided biofilms and bulk water samples into separate clusters (P = 0.027). Bacteria associated with Nitrospira moscoviensis were found in all samples and encompassed 39% of the sequenced clones in the bulk water and 25% of the biofilm community. The close association with Nitrospira suggested that a large part of the population had an autotrophic metabolism using nitrite as an electron donor. To test this hypothesis, nitrite was added to biofilm and bulk water samples, and the utilization was monitored during 15 days. A first-order decrease in nitrite concentration was observed for all samples with a rate corresponding to 0.5 × 105 to 2 × 105 nitrifying cells/ml in the bulk water and 3 × 105 cells/cm2 on the pipe surface. The finding of an abundant nitrite-oxidizing microbial population suggests that nitrite is an important substrate in this system, potentially as a result of the low assimilable organic carbon concentration. This finding implies that microbial communities in water distribution systems may control against elevated nitrite concentrations but also contain large indigenous populations that are capable of assisting the depletion of disinfection agents like chloramines. 相似文献
3.
Accumulation and Fate of Microorganisms and Microspheres in Biofilms Formed in a Pilot-Scale Water Distribution System 总被引:1,自引:3,他引:1 下载免费PDF全文
Jonas Lngmark Michael V. Storey Nicholas J. Ashbolt Thor-Axel Stenstrm 《Applied microbiology》2005,71(2):706-712
The accumulation and fate of model microbial “pathogens” within a drinking-water distribution system was investigated in naturally grown biofilms formed in a novel pilot-scale water distribution system provided with chlorinated and UV-treated water. Biofilms were exposed to 1-μm hydrophilic and hydrophobic microspheres, Salmonella bacteriophages 28B, and Legionella pneumophila bacteria, and their fate was monitored over a 38-day period. The accumulation of model pathogens was generally independent of the biofilm cell density and was shown to be dependent on particle surface properties, where hydrophilic spheres accumulated to a larger extent than hydrophobic ones. A higher accumulation of culturable legionellae was measured in the chlorinated system compared to the UV-treated system with increasing residence time. The fate of spheres and fluorescence in situ hybridization-positive legionellae was similar and independent of the primary disinfectant applied and water residence time. The more rapid loss of culturable legionellae compared to the fluorescence in situ hybridization-positive legionellae was attributed to a loss in culturability rather than physical desorption. Loss of bacteriophage 28B plaque-forming ability together with erosion may have affected their fate within biofilms in the pilot-scale distribution system. The current study has demonstrated that desorption was one of the primary mechanisms affecting the loss of microspheres, legionellae, and bacteriophage from biofilms within a pilot-scale distribution system as well as disinfection and biological grazing. In general, two primary disinfection regimens (chlorination and UV treatment) were not shown to have a measurable impact on the accumulation and fate of model microbial pathogens within a water distribution system. 相似文献
4.
Marine Ammonia- and Nitrite-Oxidizing Bacteria: Serological Diversity Determined by Immunofluorescence in Culture and in the Environment 总被引:2,自引:8,他引:2 下载免费PDF全文
Immunofluorescence assays for marine ammonium- and nitrite-oxidizing bacteria were used to assess the diversity of nitrifying bacteria isolated from marine environments. The antisera show relatively broad specificity, in that each reacts with several strains of the same physiological type as the strain to which the antiserum was prepared. The antisera do not, however, react with any strains of differing physiological type. Seventy percent of the 30 unidentified ammonium-oxidizing isolates tested reacted with one or both of the antisera produced to marine ammonium-oxidizing strains, and 8 of the 9 unidentified nitrite-oxidizing strains tested reacted with 1 or more of the 3 nitrite oxidizer antisera used. Ammonium- and nitrite-oxidizing bacteria were enumerated in samples taken in a depth profile (to 750 m) in the Southern California Bight by immunofluorescence assays for two ammonium oxidizers and two nitrite oxidizers. Average abundances of the two types of nitrifiers were 3.5 × 105 and 2.8 × 105 cells liter−1, respectively. Nitrifiers constitute 0.1 to 0.8% of the total bacterial population in these samples. 相似文献
5.
Composition and Dynamics of Bacterial Communities of a Drinking Water Supply System as Assessed by RNA- and DNA-Based 16S rRNA Gene Fingerprinting 总被引:1,自引:0,他引:1 下载免费PDF全文
Stefan Eichler Richard Christen Claudia Hltje Petra Westphal Julia Btel Ingrid Brettar Arndt Mehling Manfred G. Hfle 《Applied microbiology》2006,72(3):1858-1872
6.
Jennifer L. A. Shaw Paul Monis Laura S. Weyrich Emma Sawade Mary Drikas Alan J. Cooper 《Applied and environmental microbiology》2015,81(18):6463-6473
Drinking water assessments use a variety of microbial, physical, and chemical indicators to evaluate water treatment efficiency and product water quality. However, these indicators do not allow the complex biological communities, which can adversely impact the performance of drinking water distribution systems (DWDSs), to be characterized. Entire bacterial communities can be studied quickly and inexpensively using targeted metagenomic amplicon sequencing. Here, amplicon sequencing of the 16S rRNA gene region was performed alongside traditional water quality measures to assess the health, quality, and efficiency of two distinct, full-scale DWDSs: (i) a linear DWDS supplied with unfiltered water subjected to basic disinfection before distribution and (ii) a complex, branching DWDS treated by a four-stage water treatment plant (WTP) prior to disinfection and distribution. In both DWDSs bacterial communities differed significantly after disinfection, demonstrating the effectiveness of both treatment regimes. However, bacterial repopulation occurred further along in the DWDSs, and some end-user samples were more similar to the source water than to the postdisinfection water. Three sample locations appeared to be nitrified, displaying elevated nitrate levels and decreased ammonia levels, and nitrifying bacterial species, such as Nitrospira, were detected. Burkholderiales were abundant in samples containing large amounts of monochloramine, indicating resistance to disinfection. Genera known to contain pathogenic and fecal-associated species were also identified in several locations. From this study, we conclude that metagenomic amplicon sequencing is an informative method to support current compliance-based methods and can be used to reveal bacterial community interactions with the chemical and physical properties of DWDSs. 相似文献
7.
Pipes that transport drinking water through municipal drinking water distribution systems (DWDS) are challenging habitats for microorganisms. Distribution networks are dark, oligotrophic and contain disinfectants; yet microbes frequently form biofilms attached to interior surfaces of DWDS pipes. Relatively little is known about the species composition and ecology of these biofilms due to challenges associated with sample acquisition from actual DWDS. We report the analysis of biofilms from five pipe samples collected from the same region of a DWDS in Florida, USA, over an 18 month period between February 2011 and August 2012. The bacterial abundance and composition of biofilm communities within the pipes were analyzed by heterotrophic plate counts and tag pyrosequencing of 16S rRNA genes, respectively. Bacterial numbers varied significantly based on sampling date and were positively correlated with water temperature and the concentration of nitrate. However, there was no significant relationship between the concentration of disinfectant in the drinking water (monochloramine) and the abundance of bacteria within the biofilms. Pyrosequencing analysis identified a total of 677 operational taxonomic units (OTUs) (3% distance) within the biofilms but indicated that community diversity was low and varied between sampling dates. Biofilms were dominated by a few taxa, specifically Methylomonas, Acinetobacter, Mycobacterium, and Xanthomonadaceae, and the dominant taxa within the biofilms varied dramatically between sampling times. The drinking water characteristics most strongly correlated with bacterial community composition were concentrations of nitrate, ammonium, total chlorine and monochloramine, as well as alkalinity and hardness. Biofilms from the sampling date with the highest nitrate concentration were the most abundant and diverse and were dominated by Acinetobacter. 相似文献
8.
Biofilms in Drinking Water Distribution Systems 总被引:1,自引:0,他引:1
Batté M. Appenzeller B.M.R. Grandjean D. Fass S. Gauthier V. Jorand F. Mathieu L. Boualam M. Saby S. Block J.C. 《Reviews in Environmental Science and Biotechnology》2003,2(2-4):147-168
Biofilms and loose deposits in drinking water distribution systems provide a mosaic of electrochemical and nutritive environments. Limiting biofilms requires a combination of actions with impact is relatively low as discussed in this article. 相似文献
9.
Bacterial Contamination of Drinking Water Supplies in a Modern Rural Neighborhood 总被引:3,自引:6,他引:3 下载免费PDF全文
On six occasions during a 15-month period, the private well and spring water supplies in a modern rural neighborhood of 78 households were examined for total coliforms, fecal coliforms, Staphylococcus aureus, and standard plate count bacteria. More than one-third of the water supplies were unsatisfactory on at least one occasion as judged by standard plate counts over 103/ml and the presence of coliforms, fecal coliforms, and/or S. aureus. Citrobacter freundii, Klebsiella pneumoniae, and Escherichia coli were the most frequently isolated total coliforms. At least 12 other genera of bacteria were identified from standard plate count agar. Coliform contamination was found to be higher after periods of rainfall, and high standard plate counts were more prevalent during warmer weather. These observations probably reflect leakage of surface water into improperly sealed wells or aquifer contamination during winter and the lack of chlorination to control microbial regrowth during the warm season. An inverse correlation was found between the presence of high standard plate counts and incidence of coliforms. Consumer education and at least a twice yearly monitoring of private water supplies (winter and summer) are suggested methods to signal that treatment may be necessary to reduce the risk of waterborne disease. 相似文献
10.
The purpose of a drinking water distribution system is to deliver drinking water to the consumer, preferably with the same quality as when it left the treatment plant. In this context, the maintenance of good microbiological quality is often referred to as biological stability, and the addition of sufficient chlorine residuals is regarded as one way to achieve this. The full-scale drinking water distribution system of Riga (Latvia) was investigated with respect to biological stability in chlorinated drinking water. Flow cytometric (FCM) intact cell concentrations, intracellular adenosine tri-phosphate (ATP), heterotrophic plate counts and residual chlorine measurements were performed to evaluate the drinking water quality and stability at 49 sampling points throughout the distribution network. Cell viability methods were compared and the importance of extracellular ATP measurements was examined as well. FCM intact cell concentrations varied from 5×103 cells mL−1 to 4.66×105 cells mL−1 in the network. While this parameter did not exceed 2.1×104 cells mL−1 in the effluent from any water treatment plant, 50% of all the network samples contained more than 1.06×105 cells mL−1. This indisputably demonstrates biological instability in this particular drinking water distribution system, which was ascribed to a loss of disinfectant residuals and concomitant bacterial growth. The study highlights the potential of using cultivation-independent methods for the assessment of chlorinated water samples. In addition, it underlines the complexity of full-scale drinking water distribution systems, and the resulting challenges to establish the causes of biological instability. 相似文献
11.
Wang H Edwards M Falkinham JO Pruden A 《Applied and environmental microbiology》2012,78(17):6285-6294
The spread of opportunistic pathogens via public water systems is of growing concern. The purpose of this study was to identify patterns of occurrence among three opportunistic pathogens (Legionella pneumophila, Mycobacterium avium, and Pseudomonas aeruginosa) relative to biotic and abiotic factors in two representative chloraminated drinking water distribution systems using culture-independent methods. Generally, a high occurrence of Legionella (≥69.0%) and mycobacteria (100%), lower occurrence of L. pneumophila (≤20%) and M. avium (≤33.3%), and rare detection of Pseudomonas aeruginosa (≤13.3%) were observed in both systems according to quantitative PCR. Also, Hartmanella vermiformis was more prevalent than Acanthamoeba, both of which are known hosts for opportunistic pathogen amplification, the latter itself containing pathogenic members. Three-minute flushing served to distinguish distribution system water from plumbing in buildings (i.e., premise plumbing water) and resulted in reduced numbers of copies of Legionella, mycobacteria, H. vermiformis, and 16S rRNA genes (P < 0.05) while yielding distinct terminal restriction fragment polymorphism (T-RFLP) profiles of 16S rRNA genes. Within certain subgroups of samples, some positive correlations, including correlations of numbers of mycobacteria and total bacteria (16S rRNA genes), H. vermiformis and total bacteria, mycobacteria and H. vermiformis, and Legionella and H. vermiformis, were noted, emphasizing potential microbial ecological relationships. Overall, the results provide insight into factors that may aid in controlling opportunistic pathogen proliferation in real-world water systems. 相似文献
12.
Long-Term Succession of Structure and Diversity of a Biofilm Formed in a Model Drinking Water Distribution System 总被引:5,自引:1,他引:5 下载免费PDF全文
Adam C. Martiny Thomas M. Jrgensen Hans-Jrgen Albrechtsen Erik Arvin Sren Molin 《Applied microbiology》2003,69(11):6899-6907
In this study, we examined the long-term development of the overall structural morphology and community composition of a biofilm formed in a model drinking water distribution system with biofilms from 1 day to 3 years old. Visualization and subsequent quantification showed how the biofilm developed from an initial attachment of single cells through the formation of independent microcolonies reaching 30 μm in thickness to a final looser structure with an average thickness of 14.1 μm and covering 76% of the surface. An analysis of the community composition by use of terminal restriction fragment length polymorphisms showed a correlation between the population profile and the age of the sample, separating the samples into young (1 to 94 days) and old (571 to 1,093 days) biofilms, whereas a limited spatial variation in the biofilm was observed. A more detailed analysis with cloning and sequencing of 16S rRNA fragments illustrated how a wide variety of cells recruited from the bulk water initially attached and resulted in a species richness comparable to that in the water phase. This step was followed by the growth of a bacterium which was related to Nitrospira, which constituted 78% of the community by day 256, and which resulted in a reduction in the overall richness. After 500 days, the biofilm entered a stable population state, which was characterized by a greater richness of bacteria, including Nitrospira, Planctomyces, Acidobacterium, and Pseudomonas. The combination of different techniques illustrated the successional formation of a biofilm during a 3-year period in this model drinking water distribution system. 相似文献
13.
采用16SrRNA基因克隆一变性梯度凝胶电泳分析方法研究了石油集输系统原油和油田产水中的微生物群落结构。变性梯度凝胶电泳图谱显示:油田产水中微生物群落远比原油中的菌群丰富。所有的油田水样和原油样本中都存在与Ochrobactrum sp.和Stenotrophomonas sp.相关的细菌;原油样本中检测出与Burkholderia sp.、Brevundimonas sp.和Propionibacterium sp.相关的细菌,而这些细菌在油田水样中未检出;在油田水样中检出与Hippea sp.、Acidovorax sp.、Arcobacter sp.、Pseudomonas sp.、Thiomicrospira sp.、Brevibacterium sp.、Tissierella sp.和Peptostreptococcus sp.相关的细菌,而这些细菌在原油样本中未检出。用古细菌特异性引物进行检测发现在油田水样中存在与Methanomicrobials和Methanosarcinales相关的产甲烷菌,而这些细菌在原油样本中未检出。在石油集输过程中,油田水样和原油中微生物群落的相似性分别为83.3%和88.2%,说明微生物群落结构较为稳定。 相似文献
14.
Yendi E. Navarro-Noya Mayra C. Suárez-Arriaga Aketzally Rojas-Valdes Nina M. Montoya-Ciriaco Selene Gómez-Acata Fabián Fernández-Luqueño Luc Dendooven 《Microbial ecology》2013,66(1):19-29
Wells used for drinking water often have a large biomass and a high bacterial diversity. Current technologies are not always able to reduce the bacterial population, and the threat of pathogen proliferation in drinking water sources is omnipresent. The environmental conditions that shape the microbial communities in drinking water sources have to be elucidated, so that pathogen proliferation can be foreseen. In this work, the bacterial community in nine water wells of a groundwater aquifer in Northern Mexico were characterized and correlated to environmental characteristics that might control them. Although a large variation was observed between the water samples, temperature and iron concentration were the characteristics that affected the bacterial community structure and composition in groundwater wells. Small increases in the concentration of iron in water modified the bacterial communities and promoted the growth of the iron-oxidizing bacteria Acidovorax. The abundance of the genera Flavobacterium and Duganella was correlated positively with temperature and the Acidobacteria Gp4 and Gp1, and the genus Acidovorax with iron concentrations in the well water. Large percentages of Flavobacterium and Pseudomonas bacteria were found, and this is of special concern as bacteria belonging to both genera are often biofilm developers, where pathogens survival increases. 相似文献
15.
Microbiology - Bacterial diversity in attached communities of the anoxic part of the Solodovka wetland (Samara region, Russia), which feeds on cold karst springs with a high (>3 mM) sulfide... 相似文献
16.
17.
In the environment, multiple microorganisms coexist as communities, competing for resources and often associated as biofilms. In this study, single- and dual-species biofilm formation by, and specific activities of, six heterotrophic intergeneric bacteria were determined using 96-well polystyrene plates over a 72-h period. These bacteria were isolated from drinking water and identified by partial 16S rRNA gene sequencing. A series of planktonic studies was also performed, assessing the bacterial growth rate, motility, and production of quorum-sensing inhibitors (QSI). This constituted an attempt to identify key attributes allowing bacteria to effectively interact and coexist in a drinking-water environment. We observed that in both pure and dual cultures, all of the isolates formed stable biofilms within 72 h, with specific metabolic activity decreasing, in most cases, with an increase in biofilm mass. The largest single- and dual-biofilm amounts were found for Methylobacterium sp. and the combination of Methylobacterium sp. and Mycobacterium mucogenicum, respectively. Evidences of microbial interactions in dual-biofilm formation, associated with appreciable biomass variation in comparison with single biofilms, were found for the following cases: synergy/cooperation between Sphingomonas capsulata and Burkholderia cepacia, S. capsulata and Staphylococcus sp., and B. cepacia and Acinetobacter calcoaceticus and antagonism between S. capsulata and M. mucogenicum, S. capsulata and A. calcoaceticus, and M. mucogenicum and Staphylococcus sp. A neutral interaction was found for Methylobacterium sp.-M. mucogenicum, S. capsulata-Staphylococcus sp., M. mucogenicum-A. calcoaceticus, and Methylobacterium sp.-A. calcoaceticus biofilms, since the resultant dual biofilms had a mass and specific metabolic activity similar to the average for each single biofilm. B. cepacia had the highest growth rate and motility and produced QSI. Other bacteria producing QSI were Methylobacterium sp., S. capsulata, and Staphylococcus sp. However, only for S. capsulata-M. mucogenicum, S. capsulata-A. calcoaceticus, and M. mucogenicum-Staphylococcus sp., dual-biofilm formation seems to be regulated by the QSI produced by S. capsulata and Staphylococcus sp. and by the increased growth rate of S. capsulata. The parameters assessed by planktonic studies did not allow prediction and generalization of the exact mechanism regulating dual-species biofilm formation between the drinking-water bacteria. 相似文献
18.
Katharina Besemer Markus M. Moeseneder Jesus M. Arrieta Gerhard J. Herndl Peter Peduzzi 《Applied microbiology》2005,71(2):609-620
Natural floodplains play an essential role in the processing and decomposition of organic matter and in the self-purification ability of rivers, largely due to the activity of bacteria. Knowledge about the composition of bacterial communities and its impact on organic-matter cycling is crucial for the understanding of ecological processes in river-floodplain systems. Particle-associated and free-living bacterial assemblages from the Danube River and various floodplain pools with different hydrological characteristics were investigated using terminal restriction fragment length polymorphism analysis. The particle-associated bacterial community exhibited a higher number of operational taxonomic units (OTUs) and was more heterogeneous in time and space than the free-living community. The temporal dynamics of the community structure were generally higher in isolated floodplain pools. The community structures of the river and the various floodplain pools, as well as those of the particle-associated and free-living bacteria, differed significantly. The compositional dynamics of the planktonic bacterial communities were related to changes in the algal biomass, temperature, and concentrations of organic and inorganic nutrients. The OTU richness of the free-living community was correlated with the concentration and origin of organic matter and the concentration of inorganic nutrients, while no correlation with the OTU richness of the particle-associated assemblage was found. Our results demonstrate the importance of the river-floodplain interactions and the influence of damming and regulation on the bacterial-community composition. 相似文献
19.
Protozoan Bacterivory and Escherichia coli Survival in Drinking Water Distribution Systems 总被引:1,自引:0,他引:1 下载免费PDF全文
The development of bacterial communities in drinking water distribution systems leads to a food chain which supports the growth of macroorganisms incompatible with water quality requirements and esthetics. Nevertheless, very few studies have examined the microbial communities in drinking water distribution systems and their trophic relationships. This study was done to quantify the microbial communities (especially bacteria and protozoa) and obtain direct and indirect proof of protozoan feeding on bacteria in two distribution networks, one of GAC water (i.e., water filtered on granular activated carbon) and the other of nanofiltered water. The nanofiltered water-supplied network contained no organisms larger than bacteria, either in the water phase (on average, 5 × 107 bacterial cells liter−1) or in the biofilm (on average, 7 × 106 bacterial cells cm−2). No protozoa were detected in the whole nanofiltered water-supplied network (water plus biofilm). In contrast, the GAC water-supplied network contained bacteria (on average, 3 × 108 cells liter−1 in water and 4 × 107 cells cm−2 in biofilm) and protozoa (on average, 105 cells liter−1 in water and 103 cells cm−2 in biofilm). The water contained mostly flagellates (93%), ciliates (1.8%), thecamoebae (1.6%), and naked amoebae (1.1%). The biofilm had only ciliates (52%) and thecamoebae (48%). Only the ciliates at the solid-liquid interface of the GAC water-supplied network had a measurable grazing activity in laboratory test (estimated at 2 bacteria per ciliate per h). Protozoan ingestion of bacteria was indirectly shown by adding Escherichia coli to the experimental distribution systems. Unexpectedly, E. coli was lost from the GAC water-supplied network more rapidly than from the nanofiltered water-supplied network, perhaps because of the grazing activity of protozoa in GAC water but not in nanofiltered water. Thus, the GAC water-supplied network contained a functional ecosystem with well-established and structured microbial communities, while the nanofiltered water-supplied system did not. The presence of protozoa in drinking water distribution systems must not be neglected because these populations may regulate the autochthonous and allochthonous bacterial populations. 相似文献
20.
Chuanwu Xi Yongli Zhang Carl F. Marrs Wen Ye Carl Simon Betsy Foxman Jerome Nriagu 《Applied and environmental microbiology》2009,75(17):5714-5718
The occurrence and spread of antibiotic-resistant bacteria (ARB) are pressing public health problems worldwide, and aquatic ecosystems are a recognized reservoir for ARB. We used culture-dependent methods and quantitative molecular techniques to detect and quantify ARB and antibiotic resistance genes (ARGs) in source waters, drinking water treatment plants, and tap water from several cities in Michigan and Ohio. We found ARGs and heterotrophic ARB in all finished water and tap water tested, although the amounts were small. The quantities of most ARGs were greater in tap water than in finished water and source water. In general, the levels of bacteria were higher in source water than in tap water, and the levels of ARB were higher in tap water than in finished water, indicating that there was regrowth of bacteria in drinking water distribution systems. Elevated resistance to some antibiotics was observed during water treatment and in tap water. Water treatment might increase the antibiotic resistance of surviving bacteria, and water distribution systems may serve as an important reservoir for the spread of antibiotic resistance to opportunistic pathogens.The occurrence and spread of antibiotic-resistant bacteria (ARB) are pressing public health problems worldwide, and aquatic ecosystems are a recognized reservoir for ARB and antibiotic resistance genes (ARGs) (4, 6, 8, 11, 12, 15, 39). Naturally occurring ARB and ARGs in the aquatic environment are selected for and enriched for by antibiotics found in sewage and agricultural runoff, which result from the widespread and increased use of antibiotics (4, 11, 12, 15, 38). Historically, concerns about the microbial quality of drinking water have focused on the occurrence of pathogens in drinking water distribution systems (5, 34). However, the presence of trace levels of antibiotics and ARB in source water and finished drinking water may also greatly affect public health and is an emerging issue for the general public and the drinking water industry (3, 30). Although several studies have detected ARB in drinking water systems (2, 3, 20, 30, 38), most previous studies focused on cultivable bacteria and/or indicator organisms. Little is known about the fate of ARGs in drinking water systems, and it was recently proposed that ARGs are emerging contaminants (24).We used culture-dependent methods and molecular techniques to investigate the prevalence and dynamics of heterotrophic ARB and ARGs in a drinking water source (source RW-P) and treated drinking water (source DW-P) (see Materials and Methods in the supplemental material). We tested water from a drinking water plant located in Michigan and tap water from several small cities located in Michigan and Ohio (sources TW-1, TW-2, TW-3, and TW-4). Two independent samples were collected each time at each collection site at three different times, and we used four replicates from each sample for tests. We tested bacterial resistance to the following antibiotics: amoxicillin (amoxicilline), chloramphenicol, ciprofloxacin, gentamicin, rifampin (rifampicin), sulfisoxazole, and tetracycline. We also examined the presence of eight ARGs, including beta-lactam resistance genes (blaTEM and blaSHV), chloramphenicol resistance genes (cat and cmr), sulfonamide resistance genes (sulI and sulII), and tetracycline resistance genes (tetO and tetW).Total heterotrophic plate counts (HPC) were determined using R2A agar without added antibiotics. The water treatment process reduced the total HPC from 9.9 × 106 CFU/100 ml in source water to 68 CFU/100 ml in treated drinking water, indicating that there was efficient removal and/or deactivation of total HPC (Table (Table1).1). In contrast, the total 16S rRNA gene copy number decreased from 3.4 × 107 copies/100 ml in source water to 1.6 × 106 copies/100 ml in treated drinking water (Fig. (Fig.1).1). The discrepancy between the reduction in the HPC and the reduction in the total 16S rRNA gene copy number suggests that the final disinfection step effectively inactivated bacteria but most of the dead or damaged cells were still present in finished drinking water. The number of HPC in tap water ranged from 3.44 × 102 to 6.1 × 104 CFU/100 ml water, values that are lower than those for source water but significantly higher than those for treated drinking water, indicating that there is regrowth of bacteria in drinking water distribution systems. The copy numbers of total 16S rRNA genes in tap water ranged from 2.45 × 105 to 1.02 × 107 copies/100 ml water. The higher levels suggested by the 16S rRNA data are consistent with results of previous studies demonstrating that only 5 to 10% and 1% of bacteria in wastewater and soil, respectively, can be cultivated or identified by culture-based methods (9, 37). A significant correlation (P < 0.05, R2 = 0.78) was found between the 16S rRNA gene copy number and the total HPC if treated drinking water (DW-P) data were not included (Fig. (Fig.1).1). This suggests that cultivable bacteria in drinking water represent only a small portion of the total bacterial biomass. Including treated drinking water (DW-P) data resulted in a distorted correlation, suggesting that a large proportion of the 16S rRNA genes present came from dead and/or damaged cells. The levels of total heterotrophic bacteria were significantly higher in tap water (TW-1) than in treated drinking water (DW-P), indicating that there was bacterial regrowth in the water distribution system.Open in a separate windowFIG. 1.Heterotrophic bacteria and the 16S rRNA gene in different water samples. (A) Copy numbers of the 16S rRNA gene and numbers of heterotrophic bacteria (CFU) in 100 ml water. (B) Correlation (P < 0.05, R2 = 0.78) between the copy number of the 16S rRNA gene and the number of heterotrophic bacteria in different water samples (without the data for DW-P). RW-P, source water from the drinking water treatment plant; DW-P, finished drinking water from the drinking water treatment plant; TW-1, tap water from the city where the drinking water treatment plant is located; TW-2, TW-3, and TW-4, tap water from three towns in Michigan and Ohio close to the city where the TW-1 drinking water treatment plant is located. The statistical analysis was done using six samples for each type of water sample. Lg, log10.
Open in a separate windowaPrevalence was defined as the percentage of resistant HPC in the total HPC. The statistical analysis was done using six samples for each type and four technical replicates for each sample.bRW-P, source water from the drinking water treatment plant; DW-P, finished drinking water from the drinking water treatment plant; TW-1, tap water from the city where the drinking water treatment plant is located; TW-2, TW-3, and TW-4, tap water from three towns in Michigan and Ohio close to the city where the TW-1 drinking water treatment plant is located.cSignificantly different from RW-P.dSignificantly different from DW-P.The prevalence of HPC resistant to antibiotics was determined using R2A agar containing amoxicillin (4 mg/liter), chloramphenicol (16 mg/liter), ciprofloxacin (2 mg/liter), gentamicin (8 mg/liter), rifampin (2 mg/liter), sulfisoxazole (256 mg/liter), or tetracycline (8 mg/liter). Some groups of heterotrophic bacteria were resistant to all of the antibiotics at the concentrations tested in all water samples (Table (Table1).1). In the source water, 14.4% of the HPC were resistant to gentamicin and 1.7% were resistant to tetracycline. The resistance of HPC to amoxicillin, chloramphenicol, and rifampin was significantly higher (P < 0.01) in treated drinking water than in source water, while the resistance to sulfisoxazole was significantly lower (P < 0.01). Compared to treated drinking water (DW-P), the resistance of HPC to tetracycline in tap water was significantly greater and the resistance to amoxicillin was significantly lower (P < 0.01). The resistance to chloramphenicol and rifampin remained higher than the resistance in source water. The prevalence of HPC antibiotic resistance in tap water samples collected from other cities varied, but the resistance of HPC to rifampin was particularly high in all tap water samples.A number of previous studies have reported that ARB are common in drinking water (2, 3, 19, 25, 33). We added to these studies by testing water both before and after treatment, as well as tap water. Although the bacterial concentration was effectively lower during water treatment, the prevalence of resistance to amoxicillin, rifampin, and chloramphenicol nevertheless increased significantly.Several studies have discovered that chlorine, an agent widely used for disinfection, selects for ARB (2, 3, 9, 16, 33, 37). Armstrong et al. (2, 3) found that there was a significant increase in the proportion of multidrug-resistant (MAR) bacteria following flash mixing with chlorine. Murray et al. (16) demonstrated that the proportion of bacteria resistant to ampicillin and cephalothin (cefalotin) in sewage increased significantly following chlorination, and they observed a significant increase in the proportion of MAR strains during chlorination in laboratory experiments. Other studies demonstrated that the susceptibility of ARB to a disinfectant and the susceptibility of antibiotic-susceptible bacteria to a disinfectant are similar (7, 28), indicating that disinfection does not select ARB but instead induces the development of antibiotic resistance. Armstrong et al. (2, 3) suggested that stress-tolerant bacteria selected by chlorination might be more antibiotic resistant, and one study found that suboptimal chlorine treatment of drinking water selected for MAR Pseudomonas aeruginosa (33).The mechanism of chlorine-induced antibiotic resistance in bacteria is unknown. It is possible that chlorine can increase expression of the multidrug efflux pumps, leading to resistance to disinfection by-products as well as antibiotics. The drinking water treatment plant that we sampled used monochloramine as a disinfectant. No previous study has reported the effects of monochlroamine disinfection on ARB, but our results suggest that monochlromaine disinfection may have an effect similar to that of chlorine disinfection.Real-time PCR was used to quantify ARGs (including cat, cmr, blaTEM, blaSHV, sulI, sulII, tetW, and tetO) in collected water samples. All ARGs tested were detected in all water samples, except for the tetO and tetW genes, which were detected only in source water (Fig. (Fig.2).2). The copy number of each ARG in 100 ml water was calculated and normalized to the copy number of the total 16S rRNA genes to determine the relative abundance of each ARG in the water samples. Compared to the copy number in finished water, the copy number of ARGs in tap water was significantly greater (P < 0.001), except for the blaSHV gene, whose copy number was not significantly different (P = 0.124); the tetO and tetW genes were not detected in the drinking water sample after treatment. In terms of the relative abundance of ARGs in bacterial populations, all ARG/16S rRNA gene ratios were less than −3 log. Compared to source water, treated drinking water had a higher abundance of the cat and blaSHV genes (P < 0.001) but a lower abundance of the sulI gene (P < 0.001) (Fig. (Fig.2).2). No significant difference in any other ARG was found. After distribution, no significant change was observed in any ARG, except that the abundance of the blaTEM gene was significantly increased (P < 0.01) compared with the abundance in treated drinking water (DW-P) or in tap water (TW-1) (Fig. (Fig.2).2). The ARGs were also present in tap water samples collected from other cities. The similarity of the abundance of ARGs in the different tap water samples is quite remarkable (Fig. (Fig.2).2). The relative abundance of all ARGs was similar to that in the TW-1 tap water sample, except that the relative abundance of sulII and blaSHV was lower in the TW-2 and TW-3 tap water samples (Fig. (Fig.22).Open in a separate windowFIG. 2.Quantities of ARGs in different water samples. The bars indicate the copy numbers of the resistance genes normalized to the 16S rRNA gene copy number, and the symbols indicate the absolute copy numbers of ARGs in 100 ml water. RW-P, source water from the drinking water treatment plant; DW-P, finished drinking water from the drinking water treatment plant; TW-1, tap water from the city where the drinking water treatment plant is located; TW-2, TW-3, and TW-4, tap water from three towns in Michigan and Ohio close to the city where the TW-1 drinking water treatment plant is located. The statistical analysis was done using six samples for each type of water sample. Lg, log10.The quantities of individual ARGs were not significantly correlated with either HPC counts or 16S rRNA genes (data not shown), indicating that the ARGs tested were not evenly distributed among the bacterial populations in the water samples. However, the overall trends in quantity were similar for some ARGs and ARB. For example, in source water, treated drinking water, and tap water (TW-1), the number of heterotrophic bacteria resistant to amoxicillin, chloramphenicol, and sulfisoxazole corresponded to the proportion of genes coding for resistance to these antibiotics (blaSHV, cat, and sulI, respectively).Bacteria may inherit resistance to some antibiotics or can develop resistance via spontaneous mutation or the acquisition of resistant genes (35). The acquisition of a resistant gene via horizontal gene transfer is the most common and easiest way for bacteria to develop antibiotic resistance both in the environment and in a host (26, 29). Many bacteria transmit ARGs, and these ARGs were recently proposed to be emerging contaminants because of their widespread occurrence in aquatic ecosystems (13, 21, 22, 24). Plasmid-mediated blaTEM and blaSHV are the most common genes coding beta-lactamases and “extended-spectrum” beta-lactamases, a major cause of resistance to beta-lactams, and they are increasingly being found in different settings worldwide (14, 23). The enzymes encoded by these genes confer unequivocal resistance to ampicillin, amoxicillin, ticarillin, and carbenicillin (32, 36). We detected blaTEM and blaSHV genes in all but one water sample, which is evidence that these genes are distributed widely in drinking water systems. The selective increases in the levels of both genes in tap water due to either water treatment or regrowth within drinking water distribution systems suggest that the spread of at least some beta-lactam-resistant determinants may occur through drinking water distribution systems.Both tetO and tetW are tetracycline resistance genes encoding ribosomal protection proteins. Both of these genes are common in intestinal and rumen environments (1, 31); thus, their presence may indicate fecal contamination (22). If the tetO and tetW genes truly represent the level of fecal contamination, our results show that drinking water treatment was effective for eliminating and controlling fecal contamination.The most frequent cause of bacterial resistance to chloramphenicol is enzymatic inactivation by acetylation of the drug via different types of chloramphenicol acetyltransferases encoded by cat genes (17), but other mechanisms, such as efflux systems, may also contribute to chloramphenicol resistance (18). The proportion of cat genes increased significantly following water treatment, suggesting that the drinking water treatment did not effectively remove or inactivate the chloramphenicol-resistant bacterial population. On the other hand, the cmr gene, an efflux pump gene related to chloramphenicol resistance, showed little variation in different water sources.Sulfonamides act as competitive inhibitors of the enzyme dihydropteroate synthase in the folic acid pathway of bacterial and some eukaryotic cells. sulI and sulII encode alternative sulfonamide-resistant dihydropteroate synthases in gram-negative clinical bacteria, and both genes commonly occur (often at roughly the same frequency) in sulfisoxazole-resistant gram-negative clinical isolates (10). The drinking water treatment process significantly decreased the abundance of the sulI gene but had no significant influence on the sulII gene.In summary, we found heterotrophic ARB and ARGs in all finished water and tap water tested, although the amounts were small. The size of the general population of bacteria followed the order source water > tap water > finished water, indicating that there was regrowth of bacteria in drinking water distribution systems; elevated resistance to some antibiotics was observed during water treatment and in tap water. We show that the quantities of most ARGs are greater in tap water than in finished water and source water. The increased levels of ARGs and specialized groups of ARB in tap water compared to finished water and source water suggest that water treatment could increase the antibiotic resistance of surviving bacteria and/or induce transfer of ARGs among certain bacterial populations. Water distribution systems could serve as an incubator for growth of certain ARB populations and as an important reservoir for the spread of antibiotic resistance to opportunistic pathogens. Drinking water treatment processes and distribution systems can impact the spread of antibiotic resistance. Rusin et al. (27) estimated that the risk of infection by bacteria in drinking water was as low as 7.3 per billion people for exposure to low levels of Aeromonas and as high as 98 per 100 patients receiving antibiotic treatment exposed to high levels of Pseudomonas (27). Whether exposure to ARB results in an increased risk to the general public, particularly individuals with compromised immune systems, the very young, the very old, or individuals with chronic conditions, is not known and deserves further study. Future research should identify factors accounting for the selective increase in antibiotic resistance and develop new methods and approaches to reduce accumulation of such resistance. 相似文献
TABLE 1.
Prevalence of ARB HPC in source water, finished drinking water, and tap water from four townsaSampleb | Total HPC (CFU/100 ml) | % of total HPC resistant to:
| ||||||
---|---|---|---|---|---|---|---|---|
Amoxicillin | Ciprofloxacin | Chloramphenicol | Gentamicin | Rifampin | Sulfisoxazole | Tetracycline | ||
RW-P | 1.19 × 106 | 11.67 ± 4.39 | 11.60 ± 5.92 | 4.17 ± 1.93 | 14.42 ± 5.52 | 10.85 ± 3.57 | 7.46 ± 3.87 | 1.66 ± 0.80 |
DW-P | 68 | 39.55 ± 9.79c | 4.77 ± 4.71 | 19.45 ± 5.60c | 21.96 ± 14.43 | 47.98 ± 17.99c | 1.17 ± 1.14c | 1.50 ± 1.24 |
TW-1 | 1.6 × 104 | 15.22 ± 2.73d | 9.99 ± 4.76 | 13.96 ± 3.70c | 13.40 ± 1.73 | 62.00 ± 8.96c | 3.34 ± 1.21 | 3.78 ± 0.93c,d |
TW-2 | 6.04 × 104 | 3.02 ± 0.19 | 13.14 ± 0.48 | 5.49 ± 0.47 | 4.67 ± 0.21 | 28.10 ± 1.72 | 7.85 ± 0.67 | 0.08 ± 0.01 |
TW-3 | 3.44 × 102 | 4.07 ± 0.17 | 0.18 ± 0.07 | 0.75 ± 0.39 | 2.18 ± 0.62 | 82.15 ± 1.50 | 0.33 ± 0.03 | 0.98 ± 0.38 |
TW-4 | 2.46 × 103 | 14.33 ± 1.74 | 0.18 ± 0.05 | 2.05 ± 0.04 | 9.76 ± 0.34 | 14.23 ± 1.69 | 0.12 ± 0.001 | 0.04 ± 0.002 |