首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.

Background

Dengue is the most important mosquito-borne viral disease in the world. Dengue virus infection may be asymptomatic or lead to undifferentiated fever, dengue fever with or without warning signs, or severe dengue. Lower respiratory symptoms are unusual and lung-imaging data in patients with dengue are scarce.

Methodology/Principal Findings

To evaluate lung changes associated with dengue infection, we retrospectively analyzed 2,020 confirmed cases of dengue. Twenty-nine of these patients (11 females and 18 males aged 16–90 years) underwent chest computed tomography (CT), which yielded abnormal findings in 17 patients: 16 patients had pleural effusion (the sole finding in six patients) and 11 patients had pulmonary abnormalities. Lung parenchyma involvement ranged from subtle to moderate unilateral and bilateral abnormalities. The most common finding was ground-glass opacity in eight patients, followed by consolidation in six patients. Less common findings were airspace nodules (two patients), interlobular septal thickening (two patients), and peribronchovascular interstitial thickening (one patient). Lung histopathological findings in four fatal cases showed thickening of the alveolar septa, hemorrhage, and interstitial edema.

Conclusions/Significance

In this largest series involving the use of chest CT to evaluate lung involvement in patients with dengue, CT findings of lower respiratory tract involvement were uncommon. When abnormalities were present, pleural effusion was the most frequent finding and lung involvement was often mild or moderate and bilateral. Extensive lung abnormalities are infrequent even in severe disease and when present should lead physicians to consider other diagnostic possibilities.  相似文献   

2.
3.
4.
Movement of the target object during cone-beam computed tomography (CBCT) leads to motion blurring artifacts. The accuracy of manual image matching in image-guided radiotherapy depends on the image quality. We aimed to assess the accuracy of target position localization using free-breathing CBCT during stereotactic lung radiotherapy. The Vero4DRT linear accelerator device was used for the examinations. Reference point discrepancies between the MV X-ray beam and the CBCT system were calculated using a phantom device with a centrally mounted steel ball. The precision of manual image matching between the CBCT and the averaged intensity (AI) images restructured from four-dimensional CT (4DCT) was estimated with a respiratory motion phantom, as determined in evaluations by five independent operators. Reference point discrepancies between the MV X-ray beam and the CBCT image-guidance systems, categorized as left-right (LR), anterior-posterior (AP), and superior-inferior (SI), were 0.33 ± 0.09, 0.16 ± 0.07, and 0.05 ± 0.04 mm, respectively. The LR, AP, and SI values for residual errors from manual image matching were -0.03 ± 0.22, 0.07 ± 0.25, and -0.79 ± 0.68 mm, respectively. The accuracy of target position localization using the Vero4DRT system in our center was 1.07 ± 1.23 mm (2 SD). This study experimentally demonstrated the sufficient level of geometric accuracy using the free-breathing CBCT and the image-guidance system mounted on the Vero4DRT. However, the inter-observer variation and systematic localization error of image matching substantially affected the overall geometric accuracy. Therefore, when using the free-breathing CBCT images, careful consideration of image matching is especially important.  相似文献   

5.
PurposeThe image noise and image quality of a prototype ultra-high-resolution computed tomography (U-HRCT) scanner was evaluated and compared with those of conventional high-resolution CT (C-HRCT) scanners.ResultsThe image noise for U-HRCT (100.87 ± 0.51 Hounsfield units [HU]) was greater than that for C-HRCT (40.41 ± 0.52 HU; P < .0001). The image quality of U-HRCT was graded as superior to that of C-HRCT (P < .0001) for all of the following parameters that were examined: margins of subsolid and solid nodules, edges of solid components and pulmonary vessels in subsolid nodules, air bronchograms, pleural indentations, margins of pulmonary vessels, edges of bronchi, and interlobar fissures.ConclusionDespite a larger image noise, the prototype U-HRCT scanner had a significantly better image quality than the C-HRCT scanners.  相似文献   

6.
Most existing X-ray computed tomography (CT) techniques work in single-mounted mode and need to scan the inspected objects one by one. It is time-consuming and not acceptable for the inspection in a large scale. In this paper, we report a multi-mounted CT method and its first engineering implementation. It consists of a multi-mounted scanning geometry and the corresponding algebraic iterative reconstruction algorithm. This approach permits the CT rotation scanning of multiple objects simultaneously without the increase of penetration thickness and the signal crosstalk. Compared with the conventional single-mounted methods, it has the potential to improve the imaging efficiency and suppress the artifacts from the beam hardening and the scatter. This work comprises a numerical study of the method and its experimental verification using a dataset measured with a developed multi-mounted X-ray CT prototype system. We believe that this technique is of particular interest for pushing the engineering applications of X-ray CT.  相似文献   

7.
8.

Background & Aims

The amount of drug-loaded lipiodol in an HCC tumor post-transarterial chemoembolization (TACE) correlates with the risk of local tumor recurrence. Lipiodol enhancement of a tumor on conventional CT, measured in Hounsfield units (HU), can predict tumor response. Here we investigate whether cone-beam CT (CBCT) can also be used to predict tumor response, providing the benefit of being able to optimize the patient’s treatment plan intra-procedurally.

Methods

A total of 82 HCC nodules (82 patients), ≤5 cm in diameter, were treated with balloon-occluded TACE using miriplatin between December 2013 and November 2014. For each patient, both CBCT and conventional CT images were obtained post-TACE. The degree of correlation between CBCT and conventional CT was determined by comparing identical regions of interest for each imaging modality using pixel values.

Results

The pixel values from conventional CT and CBCT were highly correlated, with a Pearson correlation coefficient of 0.912 (p<0.001). The location of the nodules within the liver did not affect the results; the correlation coefficient was 0.891 (p<0.001) for the left lobe and 0.926 (p<0.001) for the right lobe. The mean pixel value for conventional CT was 439 ± 279 HU, and the mean pixel value for CBCT was 416 ± 311 HU.

Conclusions

CBCT may be used as a substitute for conventional CT to quantitatively evaluate the amount of drug-loaded lipiodol within an HCC nodule and, hence, the efficacy of TACE treatment. The major benefit of using CBCT is the ability to predict the likelihood of local recurrence intra-procedurally, enabling subsequent treatment optimization.  相似文献   

9.
目的:分析不同病理类型囊腔样肺癌的多排螺旋CT(Multi-Detector Computed Tomography,MDCT)影像表现,以提高对该病的认识及早期诊断水平。方法:回顾性分析28例经病理证实的囊腔样肺癌的一般资料和MDCT表现,并分析不同病理类型的影像特征包括病灶大小、部位、形态分型、磨玻璃征、形态和边缘、瘤-肺界面、与支气管关系、囊腔内残留血管分隔、胸膜凹陷征、合并肺大泡等及其相关性。结果:28例囊腔样肺癌包括18例腺癌,3例微浸润腺癌,6例鳞癌,1例腺鳞癌。患者的平均发病年龄腺癌(60.56±8.03)和鳞癌(66.00±7.93岁)高于微浸润腺癌组(49.33±16.17岁)(F=3.449,P=0.048)。平均病灶大小腺癌(1.99±0.69 cm)和鳞癌(2.45±0.87 cm)大于微浸润腺癌(0.73±0.23 cm)(F=5.980,P=0.008)。磨玻璃征主要见于腺癌(14例,77.8%)或微浸润腺癌(3例,100.0%),与鳞癌(1例,16.7%)之间比较有统计学差异(P=0.012)。鳞癌(5例)与腺癌(2例)相比更容易显示支气管截断(P=0.003)。对不同病理类型囊腔样肺癌的其他影像特征之间比较无统计学差异(P0.05)。结论:不同病理类型囊腔样肺癌具有一定的典型CT影像特征,如磨玻璃征可高度提示腺癌或微浸润腺癌,鳞癌更容易出现支气管截断征象或肺门侧软组织影。对于不典型病灶,影像动态随访对确诊很重要。  相似文献   

10.

Background

It is time-consuming to obtain the square root of airway wall area of the hypothetical airway with an internal perimeter of 10 mm (√Aaw at Pi10), a comparable index of airway dimensions in chronic obstructive pulmonary disease (COPD), from all airways of the whole lungs using 3-dimensional computed tomography (CT) analysis. We hypothesized that √Aaw at Pi10 differs among the five lung lobes and √Aaw at Pi10 derived from one certain lung lobe has a high level of agreement with that derived from the whole lungs in smokers.

Methods

Pulmonary function tests and chest volumetric CTs were performed in 157 male smokers (102 COPD, 55 non-COPD). All visible bronchial segments from the 3rd to 5th generations were segmented and measured using commercially available 3-dimensional CT analysis software. √Aaw at Pi10 of each lung lobe was estimated from all measurable bronchial segments of that lobe.

Results

Using a mixed-effects model, √Aaw at Pi10 differed significantly among the five lung lobes (R2 = 0.78, P<0.0001). The Bland-Altman plots show that √Aaw at Pi10 derived from the right or left upper lobe had a high level of agreement with that derived from the whole lungs, while √Aaw at Pi10 derived from the right or left lower lobe did not.

Conclusion

In male smokers, CT-derived airway wall area differs among the five lung lobes, and airway wall area derived from the right or left upper lobe is representative of the whole lungs.  相似文献   

11.
Some patients with idiopathic pulmonary fibrosis (IPF) do not have honeycombing on high-resolution computed tomography (HRCT) at their initial evaluation. The clinical course and sequential changes in HRCT findings in these patients are not fully understood. We reviewed the cases of 43 patients with IPF without honeycombing on initial HRCT from institutions throughout Japan. All patients were diagnosed with IPF based on a surgical lung biopsy. Multidisciplinary discussions were held five times between 2011 and 2014, to exclude alternative etiologies. We evaluated the sequential changes in HRCT findings in 30 patients with IPF. We classified these 30 patients into three groups based on their HRCT patterns and clarified the clinical characteristics and prognosis among the groups. The patterns of all 30 patients on initial HRCT corresponded to a possible usual interstitial pneumonia (UIP) pattern which was described in the 2011 International Statement. On long-term follow-up (71.0±38.7 standard deviation [SD] months), honeycombing was seen in 16 patients (53%, the HoneyCo group); traction bronchiectasis or cysts without honeycombing was observed in 12 patients (40%, the NoHoneyCo group), and two patients showed no interval change (7%, the NoChange group) on HRCT. The mean survival periods of the HoneyCo and NoHoneyCo groups were 67.1 and 61.2 months, respectively (p = 0.76). There are some patients with IPF whose conditions chronically progress without honeycombing on HRCT. The appearance of honeycombing on HRCT during the follow-up might not be related to prognosis.  相似文献   

12.

Background

Lung disease in cystic fibrosis (CF) involves excessive inflammation, repetitive infections and development of bronchiectasis. Recently, literature on emphysema in CF has emerged, which might become an increasingly important disease component due to the increased life expectancy. The purpose of this study was to assess the presence and extent of emphysema in endstage CF lungs.

Methods

In explanted lungs of 20 CF patients emphysema was semi-quantitatively assessed on histology specimens. Also, emphysema was automatically quantified on pre-transplantation computed tomography (CT) using the percentage of voxels below -950 Houndfield Units and was visually scored on CT. The relation between emphysema extent, pre-transplantation lung function and age was determined.

Results

All CF patients showed emphysema on histological examination: 3/20 (15%) showed mild, 15/20 (75%) moderate and 2/20 (10%) severe emphysema, defined as 0–20% emphysema, 20–50% emphysema and >50% emphysema in residual lung tissue, respectively. Visually upper lobe bullous emphysema was identified in 13/20 and more diffuse non-bullous emphysema in 18/20. Histology showed a significant correlation to quantified CT emphysema (p = 0.03) and visual emphysema score (p = 0.001). CT and visual emphysema extent were positively correlated with age (p = 0.045 and p = 0.04, respectively).

Conclusions

In conclusion, this study both pathologically and radiologically confirms that emphysema is common in end-stage CF lungs, and is age related. Emphysema might become an increasingly important disease component in the aging CF population.  相似文献   

13.
14.

Background

We aimed to clarify that the size of the lung adenocarcinoma evaluated using mediastinal window on computed tomography is an important and useful modality for predicting invasiveness, lymph node metastasis and prognosis in small adenocarcinoma.

Methods

We evaluated 176 patients with small lung adenocarcinomas (diameter, 1–3 cm) who underwent standard surgical resection. Tumours were examined using computed tomography with thin section conditions (1.25 mm thick on high-resolution computed tomography) with tumour dimensions evaluated under two settings: lung window and mediastinal window. We also determined the patient age, gender, preoperative nodal status, tumour size, tumour disappearance ratio, preoperative serum carcinoembryonic antigen levels and pathological status (lymphatic vessel, vascular vessel or pleural invasion). Recurrence-free survival was used for prognosis.

Results

Lung window, mediastinal window, tumour disappearance ratio and preoperative nodal status were significant predictive factors for recurrence-free survival in univariate analyses. Areas under the receiver operator curves for recurrence were 0.76, 0.73 and 0.65 for mediastinal window, tumour disappearance ratio and lung window, respectively. Lung window, mediastinal window, tumour disappearance ratio, preoperative serum carcinoembryonic antigen levels and preoperative nodal status were significant predictive factors for lymph node metastasis in univariate analyses; areas under the receiver operator curves were 0.61, 0.76, 0.72 and 0.66, for lung window, mediastinal window, tumour disappearance ratio and preoperative serum carcinoembryonic antigen levels, respectively. Lung window, mediastinal window, tumour disappearance ratio, preoperative serum carcinoembryonic antigen levels and preoperative nodal status were significant factors for lymphatic vessel, vascular vessel or pleural invasion in univariate analyses; areas under the receiver operator curves were 0.60, 0.81, 0.81 and 0.65 for lung window, mediastinal window, tumour disappearance ratio and preoperative serum carcinoembryonic antigen levels, respectively.

Conclusions

According to the univariate analyses including a logistic regression and ROCs performed for variables with p-values of <0.05 on univariate analyses, our results suggest that measuring tumour size using mediastinal window on high-resolution computed tomography is a simple and useful preoperative prognosis modality in small adenocarcinoma.  相似文献   

15.
In practical applications of computed tomography imaging (CT), it is often the case that the set of projection data is incomplete owing to the physical conditions of the data acquisition process. On the other hand, the high radiation dose imposed on patients is also undesired. These issues demand that high quality CT images can be reconstructed from limited projection data. For this reason, iterative methods of image reconstruction have become a topic of increased research interest. Several algorithms have been proposed for few-view CT. We consider that the accurate solution of the reconstruction problem also depends on the system matrix that simulates the scanning process. In this work, we analyze the application of the Siddon method to generate elements of the matrix and we present results based on real projection data.  相似文献   

16.
17.

Background

Factors determining the shape of the human rib cage are not completely understood. We aimed to quantify the contribution of anthropometric and COPD-related changes to rib cage variability in adult cigarette smokers.

Methods

Rib cage diameters and areas (calculated from the inner surface of the rib cage) in 816 smokers with or without COPD, were evaluated at three anatomical levels using computed tomography (CT). CTs were analyzed with software, which allows quantification of total emphysema (emphysema%). The relationship between rib cage measurements and anthropometric factors, lung function indices, and %emphysema were tested using linear regression models.

Results

A model that included gender, age, BMI, emphysema%, forced expiratory volume in one second (FEV1)%, and forced vital capacity (FVC)% fit best with the rib cage measurements (R2 = 64% for the rib cage area variation at the lower anatomical level). Gender had the biggest impact on rib cage diameter and area (105.3 cm2; 95% CI: 111.7 to 98.8 for male lower area). Emphysema% was responsible for an increase in size of upper and middle CT areas (up to 5.4 cm2; 95% CI: 3.0 to 7.8 for an emphysema increase of 5%). Lower rib cage areas decreased as FVC% decreased (5.1 cm2; 95% CI: 2.5 to 7.6 for 10 percentage points of FVC variation).

Conclusions

This study demonstrates that simple CT measurements can predict rib cage morphometric variability and also highlight relationships between rib cage morphometry and emphysema.  相似文献   

18.

Objective

Whether the orthodontic treatment with premolar extraction and maximum anchorage in adults will lead to a narrowed upper airway remains under debated. The study aims to investigate the airway changes after orthodontic extraction treatment in adult patients with Class II and hyperdivergent skeletal malocclusion.

Materials and Methods

This retrospective study enrolled 18 adults with Class II and hyperdivergent skeletal malocclusion (5 males and 13 females, 24.1 ± 3.8 years of age, BMI 20.33 ± 1.77 kg/m2). And 18 untreated controls were matched 1:1 with the treated patients for age, sex, BMI, and skeletal pattern. CBCT images before and after treatment were obtained. DOLPHIN 11.7 software was used to reconstruct and measure the airway size, hyoid position, and craniofacial structures. Changes in the airway and craniofacial parameters from pre to post treatment were assessed by Wilcoxon signed rank test. Mann-Whitney U test was used in comparisons of the airway parameters between the treated patients and the untreated controls. Significant level was set at 0.05.

Results

The upper and lower incisors retracted 7.87 mm and 6.10 mm based on the measurement of U1-VRL and L1-VRL (P < 0.01), while the positions of the upper and lower molars (U6-VRL, and L6-VRL) remained stable. Volume, height, and cross-sectional area of the airway were not significantly changed after treatment, while the sagittal dimensions of SPP-SPPW, U-MPW, PAS, and V-LPW were significantly decreased (P < 0.05), and the morphology of the cross sections passing through SPP-SPPW, U-MPW, PAS, and V-LPW became anteroposteriorly compressed (P <0.001). No significant differences in the airway volume, height, and cross-sectional area were found between the treated patients and untreated controls.

Conclusions

The airway changes after orthodontic treatment with premolar extraction and maximum anchorage in adults are mainly morphological changes with anteroposterior dimension compressed in airway cross sections, rather than a decrease in size.  相似文献   

19.

Purpose

Scatter is a very important artifact causing factor in dental cone-beam CT (CBCT), which has a major influence on the detectability of details within images. This work aimed to improve the image quality of dental CBCT through scatter correction.

Methods

Scatter was estimated in the projection domain from the low frequency component of the difference between the raw CBCT projection and the projection obtained by extrapolating the model fitted to the raw projections acquired with 2 different sizes of axial field-of-view (FOV). The function for curve fitting was optimized by using Monte Carlo simulation. To validate the proposed method, an anthropomorphic phantom and a water-filled cylindrical phantom with rod inserts simulating different tissue materials were scanned using 120 kVp, 5 mA and 9-second scanning time covering an axial FOV of 4 cm and 13 cm. The detectability of the CT image was evaluated by calculating the contrast-to-noise ratio (CNR).

Results

Beam hardening and cupping artifacts were observed in CBCT images without scatter correction, especially in those acquired with 13 cm FOV. These artifacts were reduced in CBCT images corrected by the proposed method, demonstrating its efficacy on scatter correction. After scatter correction, the image quality of CBCT was improved in terms of target detectability which was quantified as the CNR for rod inserts in the cylindrical phantom.

Conclusions

Hopefully the calculations performed in this work can provide a route to reach a high level of diagnostic image quality for CBCT imaging used in oral and maxillofacial structures whilst ensuring patient dose as low as reasonably achievable, which may ultimately make CBCT scan a reliable and safe tool in clinical practice.  相似文献   

20.

Objectives

To investigate the frequency of aortic calcifications at the outer edge of the false lumen and the frequency of fully circular aortic calcifications in a consecutive series of patients with aortic dissection who underwent contrast-enhanced CT.

Methods

The study population compromised of 69 consecutive subjects aged 60 years and older with a contrast-enhanced CT scan demonstrating an aortic dissection. All CT scans were evaluated for the frequency of aortic calcifications at the outer edge of the false lumen and the frequency of fully circular aortic calcifications by two experienced observers. Between observer reliability was evaluated by using Cohen’s Kappa. Differences between groups were tested using unpaired T test and Chi-square test.

Results

Presumed media calcifications were observed in 22 (32%) patients of 60 years and older and were found more frequently in chronic aortic dissection (N = 12/23, 52%) than in acute aortic dissection (N = 10/46, 22%).

Conclusion

As the intima has been torn away by the aortic dissection it is highly likely that CT scans can visualize the calcifications in the tunica media of the aorta.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏