首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
R. H. Allen 《CMAJ》1965,93(14):760-761
Many new types of laboratory equipment are appearing on the market, as well as a large number of reagent sets or kits. The importance of adequate evaluation of the reliability of such new products cannot be overemphasized.Commercially prepared reagent sets or kits fall into two categories. In the one, a set of reagents is offered for use in performance of a particular conventional procedure; this type of prepared reagent should present no problem, provided that the reagents are stable. In the other category, a reagent kit or set is offered which has been designed to simplify the performance of a laboratory analysis, often by combining reagents and reducing the number of steps and the time required. Such a kit should be evaluated carefully in order to determine its efficiency and limitations. In general it is difficult to simplify greatly a laboratory procedure without sacrificing its accuracy.  相似文献   

2.
Developing a statistical support system for environmental hazard evaluation   总被引:1,自引:1,他引:0  
Estimating the hazard or risk to both human health and the environment has been based almost exclusively on single species toxicity tests low in environmental realism and without validation of their accuracy in more complex systems. While this may be quite appropriate for humans in a large variety of circumstances, there is no substantive body of direct experimental evidence indicating that precise predictions of harm from hazardous materials can be extrapolated from single species laboratory tests (or even multispecies laboratory tests) to the more complex highly variable natural systems. Now added to the hazardous chemical assessment problem is the accidental or deliberate release of genetically engineered microorganisms into the environment that have the additional capability of multiplying and expanding their numbers and also transferring genetic information to other organisms. This paper focuses entirely on hazard evaluation for organisms other than humans, namely predicting the potential risk or probability of harm to natural systems based on laboratory toxicity testing using single species. Not only will the basic risk assessment strategy itself be examined but also the question of determining the statistical reliability of various extrapolations from one level of biological organization to another. ‘For every complex problem, there is a simple, direct solution ... and it is invariably wrong!’ H. L. Mencken  相似文献   

3.
The influence of the OF activity of group A streptococci on their specific pathogenic properties has been shown, which is manifested by increased virulence of these streptococci for children of younger age groups and by a two times higher isolation rate of OF+ strains in tonsillitis than in scarlet fever. The possibility of the indirect evaluation of the content of anti-M-antibodies by the results of the anti-OF test has been revealed, which permits using this test instead of the bactericidal test, more complicated, in the study of immunity to infection induced by group A OF+ streptococci. Among the main methods of laboratory support of epidemiological surveillance on streptococcal infection, the introduction of the highly discriminating OF typing and the anti-OF test into practical use is recommended.  相似文献   

4.
PURPOSE OF REVIEW: Cardiovascular risk scoring is incorporated in guidelines and recommended for targeting preventive treatment. Evidence is required on the most appropriate method, its accuracy in a given population, and its effectiveness in favourably influencing clinical behaviour and health outcomes. RECENT FINDINGS: Recent risk scores address inaccuracies that arise when methods are transferred between populations, and specific methods and recalibrations are described for use in low-risk populations. Ethnic and social differences in risk are also recognized in the context of cardiovascular risk scoring.More sensitive measures of known risk factors and numerous emerging risk factors are reported and new statistical methods and sources of data suggested. Little emphasis has been placed on evaluation of the clinical effectiveness of cardiovascular risk scores. Education in cardiovascular risk assessment may help improve uptake of methods by healthcare professionals. SUMMARY: Numerous risk scoring methods are available to the healthcare professional but use is patchy. Accuracy varies between populations and methods have been developed to compensate for some of this variability. If risk scoring methods are to be widely used in general practice, evidence is required on both the accuracy of methods in appropriate populations and their effectiveness in improving health outcomes.  相似文献   

5.
Exploratory Activity of Rats in Three Different Environments   总被引:1,自引:0,他引:1  
Adult male hooded (Long‐Evans) rats (Rattus norvergicus) were used to compare the efficiency of three types of tests (plain open field – OF, open field with a refuge – OD, and complex environment with a refuge – EX), for the evaluation of exploratory behaviour. The results confirmed that OF is a highly aversive situation with the animals showing elevated emotional response (defecation and urination) when compared to situations containing a refuge (OD and EX). Presence of a plain arena (OF and OD) does not elicit high exploratory performance, as shown by the delayed and reduced exit from the refuge in OD when compared to EX. Thus locomotor activity in OF (covered distance, number of rearings) probably reflects more of an escape reaction than a genuine exploratory behaviour. Conversely the presence of a complex environment seems to elicit a high exploratory performance expressed as a quick exit from the refuge, an increased time in the environment (more than 75% of the observation time) and intense locomotor patterns (large covered distances, great number of rearings) but with little emotional display (reduced defecation and urination). The results thus show the importance of considering ethological factors in the choice or development of laboratory tests.  相似文献   

6.
虽然实验鼠种群的总体健康水平得到了显著的提高,但还是有很多重要的传染性病原体在实验鼠群中流行.实验鼠群的健康状况对于动物福利、科学研究甚或人类健康都很重要.所以必须要对实验鼠群进行健康监测.笔者依据自身的实践和经验,对鼠群健康监测的基本原理进行了分析,包括以下的内容:鼠群健康监测的必要性、健康检测规程的建立、哨兵鼠、常用的监测力法、样本采集原则、对检测结果的解读和应对.相信读者在了解这些基本的原理后,能设定出符合自身设施实际的鼠群健康监测计划并逐步在实践中完善.  相似文献   

7.
AIMS: To compare accuracy of genus and species level identification of presumptive enterococci isolates from the marine environment using conventional biochemical testing, four commercial identification systems and 16S rRNA sequence analysis. METHODS AND RESULTS: Ninety-seven environmental bacterial isolates identified as presumptive enterococci on mEI media were tested using conventional and Enterococcus genus screen biochemical tests, four commercial testing systems and 16S rRNA sequencing. Conventional and Enterococcus genus screen biochemical testing, 16S rRNA sequencing and two commercial test systems achieved an accuracy of > or = 94% for Enterococcus genus confirmation. Conventional biochemical testing and 16S rRNA sequencing achieved an accuracy of > or = 90% for species level identification. CONCLUSIONS: For confirmation of Enterococcus genus from mEI media, conventional or genus screen biochemical testing, 16S rRNA sequencing and the four commercial systems were correct 79-100% of the time. For speciation to an accuracy of 90% or better, either conventional biochemical testing or 16S rRNA sequencing is required. SIGNIFICANCE AND IMPACT OF THE STUDY: Accurate identification of presumptive environmental Enterococcus isolates to genus and species level is an integral part of laboratory quality assurance and further characterization of Enterococcus species from pollution incidents. This investigation determines the ability of six different methods to correctly identify environmental isolates.  相似文献   

8.
Efficient analysis of protein expression by using two-dimensional electrophoresis (2-DE) data relies on the use of automated image processing techniques. The overall success of this research depends critically on the accuracy and the reliability of the analysis software. In addition, the software has a profound effect on the interpretation of the results obtained, and the amount of user intervention demanded during the analysis. The choice of analysis software that best meets specific needs is therefore of interest to the research laboratory. In this paper we compare two advanced analysis software packages, PDQuest and Progenesis. Their evaluation is based on quantitative tests at three different levels of standard 2-DE analysis: spot detection, gel matching and spot quantitation. As test materials we use three gel sets previously used in a similar comparison of Z3 and Melanie, and three sets of gels from our own research. It was observed that the quality of the test gels critically influences the spot detection and gel matching results. Both packages were sensitive to the parameter or filter settings with respect to the tendency of finding true positive and false positive spots. Quantitation results were very accurate for both analysis software packages.  相似文献   

9.
10.
The standardization and quantitation of immunofluorescence with a Farrand microphotometer in the rabies fluorescent-antibody technique were determined. The system is useful in maintaining the quality of examinations for rabies in a public health laboratory since quantitation of reagent, equipment performance, and specificity of reaction can be evaluated. An analysis of the results demonstrates the high degree of reproducibility and the accuracy of the techniques described.  相似文献   

11.
A cooperative phenylketonuria screening program involving private nongovernmental laboratories, individual physicians and local and state health departments has been in operation for two years. The system has evolved to the point where practically all newborns are tested. The accuracy of laboratory work has been verified by an ongoing evaluation program which has resulted in continual improvement in level of performance. There are two areas in which some beneficial changes might be considered. One is the reduction of costs of the testing and follow-up by increasing volume and centralization of work. The other is greater cooperation of the medical community in collecting the data necessary to evaluate the program and expedite the final diagnosis.  相似文献   

12.

Background

Cephalometric analysis and measurements of skull parameters using X-Ray images plays an important role in predicating and monitoring orthodontic treatment. Manual analysis and measurements of cephalometric is considered tedious, time consuming, and subjected to human errors. Several cephalometric systems have been developed to automate the cephalometric procedure; however, no clear insights have been reported about reliability, performance, and usability of those systems. This study utilizes some techniques to evaluate reliability, performance, and usability metric using SUS methods of the developed cephalometric system which has not been reported in previous studies.

Methods

In this study a novel system named Ceph-X is developed to computerize the manual tasks of orthodontics during cephalometric measurements. Ceph-X is developed by using image processing techniques with three main models: enhancements X-ray image model, locating landmark model, and computation model. Ceph-X was then evaluated by using X-ray images of 30 subjects (male and female) obtained from University of Malaya hospital. Three orthodontics specialists were involved in the evaluation of accuracy to avoid intra examiner error, and performance for Ceph-X, and 20 orthodontics specialists were involved in the evaluation of the usability, and user satisfaction for Ceph-X by using the SUS approach.

Results

Statistical analysis for the comparison between the manual and automatic cephalometric approaches showed that Ceph-X achieved a great accuracy approximately 96.6%, with an acceptable errors variation approximately less than 0.5 mm, and 1°. Results showed that Ceph-X increased the specialist performance, and minimized the processing time to obtain cephalometric measurements of human skull. Furthermore, SUS analysis approach showed that Ceph-X has an excellent usability user’s feedback.

Conclusions

The Ceph-X has proved its reliability, performance, and usability to be used by orthodontists for the analysis, diagnosis, and treatment of cephalometric.
  相似文献   

13.
In vitro evaluation of sperm quality   总被引:2,自引:1,他引:1  
This paper highlights selected laboratory analyses that are currently used to evaluate sperm, and describes why results from these assays do not consistently correlate with sperm fertility. Reasons for the disconnect between the two are due in part to the definition and reliability of the fertility data collected, to the complexity of the spermatozoon itself, to imprecision of some measurements, and to uncontrollable factors not associated to either the laboratory analysis or the sperm sample. Each sperm must possess a number of different attributes to fertilize an oocyte, and individual laboratory assays measure only one or a few of these attributes. Current and past data, correlating laboratory assay data with sperm fertility are presented in an effort to determine which types of assays are important to conduct and when to conduct them. Even though laboratory assay results do not allow accurate evaluation of the fertilizing potential of a semen sample, these assays are important to enable culling of poor quality samples.  相似文献   

14.
Compared to human medicine, little is known in canine medicine regarding specific findings on semen evaluation and their correlation with fertility. Suggestions to optimize quality of semen evaluation in veterinary practice include creating standardized protocols for evaluation of all semen parameters and updating those protocols as needed; creating some form of quality control for the clinic laboratory; educating owners about our inability to predict with 100% accuracy whether dogs with poor semen quality never could impregnate a bitch or whether dogs with excellent semen quality always could impregnate a bitch; and generating protocols for further diagnostic work-up for those dogs with abnormal semen quality.  相似文献   

15.
通过对英美等发达国家卫生系统进行绩效评价分析,总结国家卫生系统绩效评价理论方法和经验。研究发现,国家卫生系统绩效评价核心过程包括参与对象确定、概念模型选择、政策背景分析、框架构建、评价实施和激励机制形成6个关键步骤。其中国家卫生系统绩效评价制定需要利益相关者全程参与,Lalonde健康影响因素模型和平衡计分卡是目前主要理论基础,国家政策背景决定了评价框架的重点和导向,成立卫生系统绩效评价管理部门是评价实施的保障,而建立激励机制是提高卫生系统绩效评价价值的重要手段。  相似文献   

16.
Wearable systems are becoming increasingly popular for gait assessment outside of laboratory settings. A single shoe-embedded sensor module can measure the foot progression angle (FPA) during walking. The FPA has important clinical utility, particularly in populations with knee osteoarthritis, as it is a target for biomechanical treatments. However, the validity and the day-to-day reliability of FPA measurement using wearable systems during over-ground walking has yet to be established. Two gait analysis sessions on 20 healthy adults were conducted. During both sessions, participants performed natural over-ground walking in a motion capture laboratory and on a 100 m linear section of outdoor athletics track. FPA was measured in the laboratory via marker trajectory data, while the sensor module measured FPA during the outdoor track walking. Validity was examined by comparing the laboratory- and sensor-measured average FPA. Day-to-day reliability was examined by comparing the sensor-measured FPA between the first and second gait analysis sessions. Average absolute error between motion capture and sensor measured FPA were 1.7° and 2.1° at session 1 and 2, respectively. A Bland and Altman plot indicated no systematic bias, with 95% limit of agreement widths of 4.2° – 5.1°. Intraclass correlation coefficient (ICC2k) analysis resulted in good to excellent validity (ICC = 0.89 – 0.91) and reliability (ICC = 0.95). Overall, the shoe-embedded sensor module is a valid and reliable method of measuring FPA during over-ground walking without the need for laboratory equipment.  相似文献   

17.
The reliability evaluation and lifetime prediction of oral restorations for dentists have always been the major concern in the field of prosthodontics. This study introduced a new methodology for dealing with stress–strength interference and an analysis to quantify the reliability of all-ceramic crowns. The response stress was based on finite element models of all-ceramic crowns, which were constructed by reverse techniques. The method utilized in this study was a probabilistic analysis that considered the all-ceramic crown as a structural component associated with multiple factors involved in the all-ceramic system including occlusal loads and mechanical properties of porcelain. The results suggested the survival probability of all-ceramic crowns after 1, 5, 10, 15, and 20 years could be computed to be 98.89%, 98.03%, 97.50%, 97.13%, and 96.93%, respectively. Probabilistic analysis methods offer a systematic technique to incorporate and account for the nature of uncertainty in ceramic restorations and allow prediction of the reliability of all-ceramic crowns under cyclic occlusal loads with accuracy.  相似文献   

18.
Automated gray matter segmentation of magnetic resonance imaging data is essential for morphometric analyses of the brain, particularly when large sample sizes are investigated. However, although detection of small structural brain differences may fundamentally depend on the method used, both accuracy and reliability of different automated segmentation algorithms have rarely been compared. Here, performance of the segmentation algorithms provided by SPM8, VBM8, FSL and FreeSurfer was quantified on simulated and real magnetic resonance imaging data. First, accuracy was assessed by comparing segmentations of twenty simulated and 18 real T1 images with corresponding ground truth images. Second, reliability was determined in ten T1 images from the same subject and in ten T1 images of different subjects scanned twice. Third, the impact of preprocessing steps on segmentation accuracy was investigated. VBM8 showed a very high accuracy and a very high reliability. FSL achieved the highest accuracy but demonstrated poor reliability and FreeSurfer showed the lowest accuracy, but high reliability. An universally valid recommendation on how to implement morphometric analyses is not warranted due to the vast number of scanning and analysis parameters. However, our analysis suggests that researchers can optimize their individual processing procedures with respect to final segmentation quality and exemplifies adequate performance criteria.  相似文献   

19.
20.
We present here microwave-based modifications of standard protein assays that dramatically reduce the time required to determine protein concentrations. Typical protein determinations involve incubation times ranging from 15–60 min. Microwave irradiation of specimens reduces this time requirement to 10–20 s without compromising accuracy or reliability. The remarkable speed with which protein determinations may be carried out using microwave enhancement greatly simplifies general laboratory procedures that depend on the estimation of protein concentrations. An erratum to this article is available at .  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号