首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
X Guan  R Cueto  P Russo  Y Qi  Q Wu 《Biomacromolecules》2012,13(9):2671-2679
Cellulose nanocrystals (CNCs) were analyzed by asymmetric flow field-flow fractionation (AF4) coupled with multiangle light scattering (MALS) detection. Small fractions were collected from the output of the AF4 apparatus for investigation by transmission electron microscopy (TEM). The influence of CNC injection amount, the number of passes through a high-pressure homogenizer, and different CNC sources on the elution behavior and particle size distribution was investigated. The AF4-MALS results on crystal length were compared with those from TEM. Peak distortion and variation in elution profiles with the increase in sample load were observed. Good resolution was obtained when the injection mass varied from 20 to 40 μg, corresponding to injections of 4-8 μL at a starting concentration of ~5 μg/μL; concentrations during the separation process and at the detector were significantly lower. As the number of homogenization treatments increased, the peak shape became narrower and more symmetrical. This indicates a narrowed crystal length distribution, but regardless of source or homogenization treatment, no CNC preparation was as uniform as tobacco mosaic virus, a well-known rigid rod model structure, whose length was found by AF4-MALS to be in agreement with literature values. CNCs derived from cotton contained longer crystals than those derived from microcrystalline cellulose, as shown by both AF4-MALS and TEM techniques. An advantage of AF4-MALS compared to TEM is the ability to sample large numbers of rodlike particles, which is challenging and time-consuming for TEM image analysis, especially without the presorting afforded by AF4. The good TMV results suggest a high degree of accuracy will pertain to the CNC size distribution measurements.  相似文献   

2.
The separation method, flow field-flow fractionation (flow FFF), is coupled on-line with multiangle laser light scattering (MALLS) for simultaneous measurement of the size and concentration of vesicles eluting continuously from the fractionator. These size and concentration data, gathered as a function of elution time, may be used to construct both number- and mass-weighted vesicle size distributions. Unlike most competing, noninvasive methods, this flow FFF/MALLS technique enables measurement of vesicle size distributions without a separate refractive index detector, calibration using particle size standards, or prior assumptions about the shape of the size distribution. Experimentally measured size distributions of vesicles formed by extrusion and detergent removal are non-Gaussian and are fit well by the Weibull distribution. Flow FFF/MALLS reveals that both the extrusion and detergent dialysis vesicle formation methods can yield nearly size monodisperse populations with standard deviations of approximately 8% about the mean diameter. In contrast to the rather low resolution of dynamic light scattering in analyzing bimodal systems, flow FFF/MALLS is shown to resolve vesicle subpopulations that differ by much less than a factor of two in mean size.  相似文献   

3.
Sodium hyaluronate (NaHA) is an ultrahigh molecular weight polysaccharide that is found in body tissues, synovial fluid, the vitreous humor, and the umbilical cord, and the size characterization of NaHA is important in pharmaceutical applications. On-line field-flow fractionation/multiangle light scattering/differential refractive index (FlFFF/MALS/DRI) has been applied for the study of degradation efficiency of sodium hyaluronate (NaHA). A NaHA raw sample was degraded by different chemical or physical methods and the degraded NaHA samples were separated using field-programming FlFFF, in which separation is achieved by differences in diffusion coefficients or hydrodynamic diameters. Separation was followed by serial detection using MALS and DRI. Molecular weight distribution (MWD) and information relating to the radius of gyration of the NaHA samples were examined for the raw and degraded NaHA samples. Samples studied include: two different products of ultrasonic degradation, two products of alkaline degradation, and four different products of enzymatic degradation. While alkaline degradation showed a moderate degradation compared to ultrasonic and enzymatic methods in reducing average MW, the latter two degradation methods showed significant changes in average molecular weight and in conformation of NaHA.  相似文献   

4.
The relatively novel combination of flow field-flow fractionation (FFF) and multiangle light scattering (MALS) was employed to study a nondegraded κ-carrageenan in different 0.1M salt solutions. The applicability of the technique was tested, and the effects of salt type and salt composition on the molar mass and radius of gyration were studied. A conformational ordering was induced at room temperature by switching the solvent from 0.1M NaCl (coil form) to 0.1M NaI (helix form). An approximate doubling of the average molar mass and an increase in radius of gyration was then observed, in agreement with results obtained previously using size exclusion chromatography–MALS. This increase in size was attributed to conformational ordering and to the formation of double helices. Severe aggregation was observed above 40% CsI in the 0.1M mixed salt solution of CsI and NaI. This was ascribed to the association of helices into large aggregates. For these large associates, having molar masses of several millions, a reversal of the elution order in flow FFF was detected. © 1998 John Wiley & Sons, Inc. Biopoly 45: 85–96 1998  相似文献   

5.
A method using a combination of asymmetric flow field-flow fractionation (AFFFF) and multiangle light scattering (MALS) techniques has been shown to improve the estimation of virus particle counts and the amount of aggregated virus in laboratory samples. The method is based on the spherical particle counting approach given by Wyatt and Weida in 2004, with additional modifications. The new method was tested by analyzing polystyrene beads and adenovirus samples, both having a well-characterized particle size and concentration. Influenza virus samples were analyzed by the new AFFFF-MALS technique, and particle size and aggregate state were compared with results from atomic force microscopy analysis. The limitations and source of possible errors for the new AFFFF-MALS analysis are discussed.  相似文献   

6.
The aim of this work was to characterize starch polysaccharides using asymmetrical flow field flow fractionation coupled with multiangle laser light scattering. Amylopectins from eight different botanical sources and rabbit liver glycogen were studied. Amylopectins and glycogen were completely solubilized and analyzed, and high mass recoveries were achieved (81.7-100.0%). Amylopectin Mw, RG, and the hydrodynamic coefficient nuG (the slope of the log-log plot of RGi vs Mi) were within the ranges 1.05-3.18 x 10(8) g mol(-1), 163-229 nm, 0.37-0.49, respectively. The data were also considered in terms of structural parameters. The results were analyzed by comparison with the theory of hyperbranched polymers (Flory, P. J. Principles of Polymer Chemistry; Cornell University Press: Ithaca, NY, 1953; Burchard, W. Macromolecules, 1977, 10, 919-927). This theory, based upon the ABC model, has been shown to underestimate the branching degrees of amylopectins. However, quantitative agreement with the data in the literature was found for amylopectins when using the ABC model modified by the introduction of a multiplying factor, determined from previously described amylopectin structures in terms of the number of branching point calculations.  相似文献   

7.
Asymmetrical flow field-flow fractionation (AsFlFFF)/multi-angle light scattering (MALS) was employed for studying filter-extruded liposomes in carrier solutions with different ionic strength and osmolarity. By dilution of preformed liposome suspensions with different media, only the ionic strength in the external free aqueous phase was changed. Under such conditions the liposomes were found to elute at almost identical elution times, which is in contrast to earlier studies. This may be explained by two opposing effects: (a) modulation of inter-particulate and particle-wall-repulsion effects and (b) osmotic stress-induced changes in vesicle size. The latter effect was demonstrated when analysing liposomes upon dilution in media of constant ionic strength, but varying osmotic pressure (with or without 150 mmol L?1 sucrose supplement). The osmotic stress-induced change in liposome size was found to be size dependent. Larger liposomes appeared to both shrink and swell when exposed to hyper- or hypoosmotic media, respectively. Smaller liposomes appeared to shrink but not to swell. The potential causes of this effect are discussed.  相似文献   

8.
In this study, we investigated the size distribution, encapsulation efficiency, and oxygen affinity of liposome-encapsulated tetrameric hemoglobin (LEHb) dispersions and correlated the data with the variation in extruder membrane pore size, ionic strength of the extrusion buffer, and hemoglobin (Hb) concentration. Asymmetric flow field-flow fractionation (AFFF) in series with multi-angle static light scattering (MASLS) was used to study the LEHb size distribution. We also introduced a novel method to measure the encapsulation efficiency using a differential interferometric refractive index (DIR) detector coupled to the AFFF-MASLS system. This technique was nondestructive toward the sample and easy to implement. LEHbs were prepared by extrusion using a lipid combination of dimyristoyl-phosphatidylcholine, cholesterol, and dimyristoyl-phosphatidylglycerol in a 10:9:1 molar ratio. Five initial Hb concentrations (50, 100, 150, 200, and 300 mg Hb per mL of buffer) extruded through five different membrane pore diameters (400, 200, 100, 80, and 50 nm) were studied. Phosphate buffered saline (PBS) and phosphate buffer (PB) both at pH 7.3 were used as extrusion buffers. Despite the variation, extrusion through 400-nm pore diameter membranes produced LEHbs smaller than the pore size, extrusion through 200-nm membranes produced LEHbs with diameters close to the pore diameter, and extrusion through 100-, 80-, and 50-nm membranes produced LEHbs larger than the pore sizes. We found that the choice of extrusion buffer had the greatest effect on the LEHb size distribution compared to either Hb concentration or extruder membrane pore size. Extrusion in PBS produced larger LEHbs and more monodisperse LEHb dispersions. However, LEHbs extruded in PB generally had higher Hb encapsulation efficiencies and lower methemoglobin (metHb) levels. The choice of extrusion buffer also affected how the encapsulation efficiency correlated with Hb concentration, extruder pore size, and the metHb level. The most optimum encapsulation efficiency and amount of Hb entrapped were achieved at the highest Hb concentration and the largest pore size for both extrusion buffers (62.38% and 187.14 mg Hb/mL of LEHb dispersion extruded in PBS, and 69.98% and 209.94 mg Hb/mL of LEHb dispersion extruded in PB). All LEHbs displayed good oxygen-carrying properties as indicated by their P(50) and cooperativity coefficients. LEHbs extruded in PB had an average P(50) of 23.04 mmHg and an average Hill number of 2.29, and those extruded in PBS had average values of 27.25 mmHg and 2.49. These oxygen-binding properties indicate that LEHbs possess strong potential as artificial blood substitutes. In addition, the metHb levels in PB-LEHb dispersions are significantly low even in the absence of antioxidants such as N-acetyl-L-cysteine.  相似文献   

9.
A constrained regularization procedure has been applied to a low-angle quasi-elastic light scattering system in order to determine particle size distributions. The conditions under which this procedure may be successfully applied to low-angle photon correlation spectroscopy have been characterized. Acquisition of photon count data over a short time period, relative to the long exponential decay constants of correlation functions obtained at low forward angles, resulted in particle size distributions which were stable with regard to peak width and weighted mean particle radius. Irrespective of the number of photon counts obtained, peak resolution and position on the particle size scale were not optimized unless anomalies in the correlation function due to transient increases in the mean photon counting rate were removed from the photon count data prior to autocorrelation. When such measures were taken, reasonable size distributions were obtained for well characterized protein standards and for liposomal suspensions.  相似文献   

10.
Conditions are described for the preparation of functional myofibrils and myosin light chains from freeze-clamped beating hearts with the state of light chain phosphorylation chemically 'frozen' during the extraction procedure. Myofibrils were shown to be functionally intact by measurement of Ca2+ binding and ATPase activity. Highly purified cardiac myosin light chains could be routinely isolated from myofibrillar preparations using ethanol fractionation together with ion-exchange chromatography. Analysis of light chains for covalent phosphate indicated that basal levels of phosphorylation of the 18--20 000 dalton light chain of myosin in rabbit hearts beating in situ or in a perfusion apparatus were 0.3--0.4 mol/mol. Covalent phosphate content of the light chain fraction did not change during perfusion of hearts with 10 microM epinephrine.  相似文献   

11.
12.
Trinitrobenzene selectively dinitrophenylates SH1, a specific thiol in the myosin heavy chain which contains 1 mol of this cysteinyl residue. When the SH1-DNP-myosin thus obtained was irradiated with a mercury lamp, a cross-linked product was formed with a molecular weight of about 220K daltons. It was shown that this product was composed of both heavy and light chains by fluorescence labeling of the heavy chain at SH2, another specific thiol, and immune reaction using an anti-light chain antibody, respectively.  相似文献   

13.
When myosin chymotryptic subfragment-1 was treated with dimethyl-suberimidate or dithiobis (succinimidylpropionate) under nearly physiological ionic conditions, the alkali light chains A1 and A2 were selectively and intramolecularly cross-linked to the 95K heavy chain. Experimental conditions were developed with both reagents for optimal production of A1 and A2-containing dimers. After conversion of reversibly cross-linked S-1 (A1+A2) into (27K-50K-20K)-S-1 derivative by restricted tryptic proteolysis, the light chains were found to be attached to the NH2-terminal 27K segment of the heavy chain.  相似文献   

14.
Makokha M  Hare M  Li M  Hays T  Barbar E 《Biochemistry》2002,41(13):4302-4311
The interactions of three subunits of cytoplasmic dynein from Drosophila melanogaster, LC8, Tctex-1, and the N-terminal domain of IC74 (N-IC74, residues 1-289), were characterized in vitro by affinity methods, limited proteolysis, and circular dichroism spectroscopy. These subunits were chosen for study because they are presumed to promote the assembly of the complex and to be engaged in the controlled binding and release of cargo. Limited proteolysis and mass spectrometry of N-IC74 in the presence of LC8 and Tctex-1 localized binding of Tctex-1 to the vicinity of K104 and K105, and localized binding of LC8 to the region downstream of K130. Circular dichroism, fluorescence, sedimentation velocity, and proteolysis studies indicate that N-IC74 has limited secondary and tertiary structure at near physiological solution conditions. Upon addition of LC8, N-IC74 undergoes a significant conformational change from largely unfolded to a more ordered structure. This conformational change is reflected in increased global protection of N-IC74 from proteolytic digestion following the interaction, and in a significant change in the CD signal. A smaller but reproducible change in the CD spectra was observed upon Tctex-1 binding as well. The increased structure introduced into N-IC74 upon light chain binding suggests a mechanism by which LC8 and Tctex-1 may regulate the assembly of the dynein complex.  相似文献   

15.
The heavy (H) and light (L) chains of murine monoclonal autoantibody 62 reacting with thyroglobulin independently express idiotypic (Id) determinants that are very similar if not identical with the Id62 expressed on the intact protein. In this report, we describe the production and characterization of rabbit antibodies to isolated H62 and L62 chains to further prove that individual chains express Id62 in an immunogenic form. The results demonstrate that both chains are capable of eliciting antibodies that, after appropriate adsorption, behave like conventional anti-Id62 antibodies prepared against the intact antibody molecule. By direct radioimmunoassay binding, competition of Id binding and Western blot anti-H62 and anti-L62 antibodies identify as Id-positive the same group of IgG1, bind in a reciprocal fashion to H- and L-chains of parental monoclonal antibody 62, and detect Id62-positive polyclonal serum autoantibodies to thyroglobulin. We conclude that monoclonal antibody 62 expresses independently a similar Id on both polypeptide chains and the intact antibody molecule, or its isolated chains, induce qualitatively similar anti-Id responses. These results are discussed in light of the possible structure/function implication such autoantibodies may have within the Id network.  相似文献   

16.
A novel embryo-specific myosin light chain of 23 kDa molecular weight (L23) was found previously in embryonic chicken skeletal, cardiac, and smooth muscles (Takano-Ohmuro et al. (1985) J. Cell Biol. 100, 2025-2030). When we examined myosin in embryonic and adult brain by two-dimensional electrophoresis, 23 kDa myosin light chain present in brain (Burridge & Bray (1975) J. Mol. Biol. 99, 1-14) comigrated with L23. Two monoclonal antibodies, EL-64 and MT-185d, were applied to clarify the identity of the brain 23 kDa myosin light chain and the chicken embryonic muscle L23. The two antibodies recognize different antigenic determinants in the L23 molecule; the former antibody is specific for L23, whereas the latter recognizes the sequence common to fast skeletal muscle myosin light chains 1 and 3, and also L23. The immunoblots combined with two-dimensional gel electrophoresis showed that both EL-64 and MT-185d can bind to the brain 23 kDa myosin light chain as well as the chicken embryonic muscle L23. These results indicate that chicken brain and chicken embryonic muscles contain a common myosin light chain of 23 kDa molecular weight.  相似文献   

17.
Isolated myosins from human predominantly fast and slow muscles, human neonatal and foetal muscle were examined for light chain composition by one- and two-dimensional electrophoresis. The LC1F, LC2F and LC3F light chains were identical with their counterparts from rabbit fast myosin. Human LC1S was identified by correlative criteria as a single component having a molecular weight slightly lower than, but an electric charge similar to, that of rabbit LC1Sb. Consequently, human LC1S appears to be much less heterogeneous relative to LC1F than is the case with other mammalian species. A high immunological cross-reactivity was likewise observed, with antibody specific to rabbit LC1F, between the isolated myosins from several human mixed muscles and rabbit fast myosin, though reactivity was highest with foetal myosin (having a pure-fast-light-chain pattern).  相似文献   

18.
A simple, sensitive and rapid flow injection analysis (FIA) method with resonance light scattering (RLS) was described for the determination of propafenone (PPF). The method was based on the ion‐association reaction of 12‐tungstophosphoric acid (TP) with propafenone. In pH 1.0 acidic medium, TP reacted with PPF to form an ion‐associate complex, which resulted in a significant enhancement of RLS intensity. The maximum scattering peak was located at 340 nm, the RLS intensity was proportional to the concentration of PPF in the range 0.003–9.0 µg/mL, and the detection limit (3σ) of 1.0 ng/mL was obtained at a sampling rate of 60 samples/h. The feasible reaction conditions and FIA parameters for the system were optimized. The method proposed in this paper shows satisfactory reproducibility with a relative standard deviation (RSD) of 2.1% for 10 successive determinations of 2.0 µg/mL PPF. The present method had been successfully applied to the determination of PPF in serum samples and pharmaceutical samples. The results obtained were in agreement with the method used in the Chinese Pharmacopoeia. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

19.
20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏