首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Ultimately, advances in genomics, proteomics and metabolomics will be realized by combining these approaches with biophysical sensors for understanding the functional and structural (physiological) aspects of sub-cellular systems (cytomics). Therefore, the emergence of the new fields of cytomics and physiomics will require new technologies to probe the functional realm of living cells. While amperometric sensors have been used, their sensitivity and reliability are significantly improved through the development of new strategies and data acquisition systems for the operation of the sensors. This includes the application of the principles of the vibrating or self-referencing microsensor to the operation of amperometric sensors. The development of self-referencing amperometry (SRA) is significant because it effectively converts static concentration sensors into dynamic biophysical sensors that directly monitor physiological flux. SRA has been developed for analytes such as O2, NO, H2O2 and ascorbate. These sensors have been validated against non-biological microscopic flux sources that were theoretically modeled, before being applied to biological research. This new sensor technology has been shown, through research in a wide variety of biological and biomedical research projects, to be an important new tool in the arsenal of the cell biologist. SRA technology has been adapted through SRA-H2O2 and SRA-NADH sensors, for electrochemically coupled enzyme based self-referencing biosensors (SRB) for glucose, glutamate and ethanol. These developments in self-referencing sensor technologies offer great promise in extending electroanalytical chemistry and biosensor technologies from the micro to the nanoscale where researchers can study physiology at the sub-cellular and organellar levels.  相似文献   

2.
The ability to non-invasively measure metabolic oxygen flux is a very important tool for physiologists interested in a variety of questions ranging from basic metabolism, growth/development, and stress adaptation. Technologies for measuring oxygen concentration near the surface of cells/tissues include electrochemical and optical techniques. A wealth of knowledge was gained using these tools for quantifying real-time physiology. Fiber-optic microprobes (optrodes) have recently been developed for measuring oxygen in a variety of biomedical and environmental applications. We have adopted the use of these optical microsensors for plant physiology applications, and used the microsensors in an advanced sensing modality known as self-referencing. Self-referencing is a non-invasive microsensor technique used for measuring real-time flux of analytes. This paper demonstrates the use of optical microsensors for non-invasively measuring rhizosphere oxygen flux associated with respiration in plant roots, as well as boundary layer oxygen flux in phytoplankton mats. Highly sensitive/selective optrodes had little to no hysteresis/calibration drift during experimentation, and an extremely high signal-to-noise ratio. We have used this new tool to compare various aspects of rhizosphere oxygen flux for roots of Glycine max, Zea mays, and Phaseolus vulgaris, and also mapped developmentally relevant profiles and distinct temporal patterns. We also characterized real-time respiratory patterns during inhibition of cytochrome and alternative oxidase pathways via pharmacology. Boundary layer oxygen flux was also measured for a phytoplankton mat during dark:light cycling and exposure to pharamacological inhibitors. This highly sensitive technology enables non-invasive study of oxygen transport in plant systems under physiologically relevant conditions.  相似文献   

3.
Glucose oxidase (EC 1.3.4.3) was immobilized on chitosan membrane (<0.1 mm in thickness) prepared from the carapace of the soldier crab Mictyris brevidactylus. A glucose electrode was constructed by covering a platinum electrode (2.0 mm in diameter) with the enzyme membrane. The enzyme electrode sensed glucose amperometrically (1.0 µA/mM, with linear range up to 0.5 mM, r = 0.999) when positively imposed with 0.6 V against an Ag/AgCl reference electrode. The glucose biosensor was sensitive (<0.1 µM, S/N > 3), reproducible (CV for 55 µM glucose <3%, n = 5), reagentless, and durable for months.  相似文献   

4.
A new amperometric whole cell biosensor based on Saccharomyces cerevisiae immobilized in gelatin was developed for selective determination of vitamin B1 (thiamine). The biosensor was constructed by using gelatin and crosslinking agent glutaraldehyde to immobilize S. cerevisiae cells on the Teflon membrane of dissolved oxygen (DO) probe used as the basic electrode system combined with a digital oxygen meter. The cells were induced by vitamin B1 in the culture medium, and the cells used it as a carbon source in the absence of glucose. So, when the vitamin B1 solution is injected into the whole cell biosensor system, an increase in respiration activity of the cells results from the metabolic activity and causes a decrease in the DO concentration of interval surface of DO probe related to vitamin B1 concentration. The response time of the biosensor is 3 min, and the optimal working conditions of the biosensor were carried out as pH 7.0, 50mM Tris-HCl, and 30 degrees C. A linear relationship was obtained between the DO concentration decrease and vitamin B1 concentration between 5.0 x 10(-3) and 10(-1) microM. In the application studies of the biosensor, sensitive determination of vitamin B1 in the vitamin tablets was investigated.  相似文献   

5.
Summary We have adapted the self-referencing microelectrode technique to allow sensitive and noninvasive measurement of oxygen fluxes around single cells. The self-referencing technique is based on the translational movement of a selective microelectrode through the gradient next to the cell wall or membrane. The electrode is moved at a known frequency and between known points. The differential electrode output values are converted into a directional measurement of flux by the Fick equation. By coupling the newly developed oxygen-selective self-referencing electrochemical microelectrode (SREM-O2) system with self-referencing ionselective proton measurements (SRIS-H+) we have characterized oxygen and proton fluxes from a single cell of the filamentous green algaSpirogyra gre illeana (Hass.). Oxygen showed a net efflux and protons showed a net influx when the cell was illuminated. These photosynthesis-dependent fluxes were found to be spatially associated with the chloroplasts and were sensitive to treatment with dichlorophenyldimethylurea. In the dark the directions of oxygen and proton fluxes were reversed. This oxygen influx was associated with mitochondrial respiration and was reduced by 78% when the cells was treated with 0.5 mM KCN. The residual cyanide-resistant respiration was inhibited by the application of 5 mM salicylhydroxamic acid, an inhibitor of the alternative oxidase. Similarly the cytochrome pathway was also inhibited by the presence of 20 M NO, while the cyanide-resistant alternative oxidase was not. These results demonstrate the use of the newly developed SREM-O2 system to measure and characterize metabolic fluxes at a level of sensitivity that allows for subcellular resolution. These measurements, in conjunction with SERIS-H+ measurements, have led to new insights in our understanding of basic cellular physiology in plant cells.Abbreviations SRIS self-referencing ion selective - SREM self-referencing electrochemical microelectrode - ICP inductive coupled plasma spectroscopy  相似文献   

6.
Like many cell types in culture, both undifferentiated and differentiated BALB/c 3T3 preadipose cells respond to glucose deprivation with an increased uptake of 2-deoxy-D-glucose (deoxyglucose) and 3-O-methyl-D-glucose (methylglucose). Glucose readdition to glucose-deprived cultures resulted in a prompt fall in uptake activity; in undifferentiated cells, a half-maximally effective concentration of glucose was approximately 0.5 mM, while 0.1 mM was ineffective. Several hexoses differed in their efficacy of "deactivating" methylglucose transport in glucose-deprived cells; it appeared that a particular hexose must be metabolized beyond the 6-phosphate form to deactivate the transport system. Previous studies have shown that the phorbol ester 12-O-tetradecanoylphorbol-13-acetate (TPA) stimulates hexose transport in undifferentiated and differentiated BALB/c 3T3 cells. In this study, it was found that TPA (and insulin in differentiated cells) prevented the glucose-induced deactivation of transport activity. Glucose-induced deactivation of transport activity was also prevented by cycloheximide or actinomycin D addition concomitantly with glucose. In glucose-starved cells, agents such as TPA and insulin appear to override a cellular control mechanism sensitive to the external concentration of glucose, so that elevated levels of transport activity are maintained under environmental conditions (i.e., a return to physiological glucose concentrations) that normally induce a fall in transport activity.  相似文献   

7.
Current techniques for characterizing biofilm physiology lack the signal filtering capability required for quantifying signals associated with real time biologically active transport. Though a great deal was learned from previous investigations, no results have been reported on the characterization of in vivo, real time biofilm flux using non-invasive (non-destructive) techniques. This article introduces the self-referencing technique for applications in biofilm physiology. Self-referencing is a non-invasive sensing modality which is capable of sensing changes in biologically active analyte flux as small as 10 fmol cm(-2) s(-1). Studies directly characterizing flux, as opposed to concentration, have the advantage of quantifying real time changes in biologically active transport which are otherwise lost to background noise. The use of this modality for characterizing biofilm physiology is validated with a reversible enzyme inhibition study. The experiment used self-referencing potentiometric sensors for quantifying real time ammonium and nitrite flux. Amperometric and optical sensing methods, though not presented herein, are also powerful sensing tools which benefit from operation in self-referencing mode. Reversible ammonia monooxygenase inhibition by a copper chelator (thiourea), and subsequent relief by excess copper addition was successfully demonstrated using self-referencing ion-selective microelectrodes for a mature Nitrosomonas europaea biofilm.  相似文献   

8.
The physiology of the early embryo may be indicative of embryo vitality and therefore methods for non-invasively monitoring physiological parameters from embryos could improve preimplantation diagnoses. The self-referencing electrophysiological technique is capable of non-invasive measurement of the physiology of individual cells by monitoring the movement of ions and molecules between the cell and the surrounding media. Here we use this technique to monitor gradients of calcium, potassium, oxygen and hydrogen peroxide around individual mouse preimplantation embryos. The calcium-sensitive electrode in self-referencing mode identified a region of elevated calcium concentration (approximately 0.25 pmol) surrounding each embryo. The calcium gradient surrounding embryos was relatively steep, such that the region of elevated calcium extended into the medium only 4 microns from the embryo. By contrast, using an oxygen-sensitive electrode an extensive gradient of reduced dissolved oxygen concentration was measured surrounding the embryo and extended tens of micrometres into the medium. A gradient of neither potassium nor hydrogen peroxide was observed around unperturbed embryos. We also demonstrate that monitoring the physiology of embryos using the self-referencing technique does not compromise their subsequent development. Blastocyts studied with the self-referencing technique implanted and developed to term at the same frequency as did unexamined, control embryos. Therefore, the self-referencing electrode provides a valuable non-invasive technique for studying the physiology and pathophysiology of individual embryos without hindering their subsequent development.  相似文献   

9.
Cortisol is a member of the glucocorticoid hormone family and a key metabolic regulator. Increased intracellular cortisol levels have been implicated in type 2 diabetes, obesity, and metabolic syndrome. Cortisol is an important bio-marker of stress and its detection is also important in sports medicine. However, rapid methods for sensitive detection of cortisol are limited. Functionalized gold nanowires were used to enhance the sensitivity and selectivity of cortisol detection. Gold nanowires are used to improve the electron transfer between the electrodes. Moreover, the large surface to volume ratio, small diffusion time and high electrical conductivity and their aligned nature will enhance the sensitivity and detection limit of the biosensor several fold. The biosensor was fabricated using, aligned gold (Au) nanowires to behave as the working electrode, platinum deposited on a silicon chip to function as the counter electrode, and silver/silver chloride as reference electrode. The gold nanowires were coupled with cortisol antibodies using covalent linkage chemistry and a fixed amount of 3alpha-hydroxysteroid dehydrogenase was introduced into the reaction cell during each measurement to convert (reduce) ketosteroid into hydroxyl steroid. Furthermore, the micro-fluidic, micro-fluid part of the sensor was fabricated using micro-electro-mechanical system (MEMS) technology to have better control on liquid flow over Au nanowires to minimize the signal to noise ratio. The biosensor was characterized using SEM, AFM and FTIR technique. The response curve of the biosensor was found to be linear in the range of 10-80 microM of cortisol. Moreover, the presence of hydrocortisone is sensitively detected in the range of 5-30 microM. It is concluded that the functionalized gold nanowires with micro-fluidic device using enzyme fragment complementation technology can provide an easy and sensitive assay for cortisol detection in serum and other biological fluids.  相似文献   

10.
Signaling and insulin secretion in β cells have been reported to demonstrate oscillatory modes, with abnormal oscillations associated with type 2 diabetes. We investigated cellular glucose influx in β cells with a self-referencing (SR) microbiosensor based on nanomaterials with enhanced performance. Dose–response analyses with glucose and metabolic inhibition studies were used to study oscillatory patterns and transporter kinetics. For the first time, we report a stable and regular oscillatory uptake of glucose (averaged period 2.9 ± 0.6 min), which corresponds well with an oscillator model. This oscillatory behavior is part of the feedback control pathway involving oxygen, cytosolic Ca2+/ATP, and insulin secretion (periodicity approximately 3 min). Glucose stimulation experiments show that the net Michaelis–Menten constant (6.1 ± 1.5 mM) is in between GLUT2 and GLUT9. Phloretin inhibition experiments show an EC50 value of 28 ± 1.6 μM phloretin for class I GLUT proteins and a concentration of 40 ± 0.6 μM phloretin caused maximum inhibition with residual nonoscillating flux, suggesting that the transporters not inhibited by phloretin are likely responsible for the remaining nonoscillatory uptake, and that impaired uptake via GLUT2 may be the cause of the oscillation loss in type 2 diabetes. Transporter studies using the SR microbiosensor will contribute to diabetes research and therapy development by exploring the nature of oscillatory transport mechanisms.  相似文献   

11.
Although glucose sensors with millimolar sensitivity are still the norm, there is now a developing interest in glucose sensors with micromolar sensitivity for applications in minimally invasive sampling techniques such as fast microdialysis and extraction of interstitial fluid by iontophoresis and laser poration. In this regard, the glucose binding protein (GBP) with a binding constant for glucose in the micromolar range is of particular relevance. GBP is one of the soluble binding proteins found in the periplasmic space of Gram-negative bacteria. Because of its hinge-like tertiary structure, glucose binding induces a large conformational change, which can be used for glucose sensing by attaching a polarity sensitive fluorescent probe to a site on the protein that is allosterically responsive to glucose binding. Correspondingly, the resulting optical biosensor has micromolar sensitivity to glucose. Because binding is reversible, the biosensor is reusable and can be stored at 4 degrees C for 6 months without losing its sensitivity. In this paper, we show the feasibility of using the GBP biosensor to monitor glucose in microdialysis. The effect of perfusion rate, bulk glucose concentration and temperature on microdialysis efficiency was determined. Additionally, the glucose concentrations in mammalian cell culture were monitored to demonstrate the applicability of this sensor in complex and dynamic processes over a period of time. As the sensor is sensitive to micromolar glucose, high dialysis efficiency is not required when the bulk glucose concentration is within the millimolar physiological range. Thus, a perfusion rate of 10 microL/min or faster can be used, resulting in delay times of 1 min or less.  相似文献   

12.
A sensitive and selective amperometric glucose biosensor based on platinum microparticles dispersed in nano-fibrous polyaniline (PANI) was investigated. Poly (m-phenylenediamine) (PMPD), which was employed as an anti-interferent barrier and a protective layer to platinum microparticles, was deposited onto platinum-modified PANI in the presence of glucose oxidase. The morphology of PANI, Pt/PANI and PMPD-GOD/Pt/PANI were investigated by scanning electron microscopy. The results show that PANI has a nano-fibrous morphology. The enzyme electrode exhibits excellent response performance to glucose with linear range from 2 x 10(-6) to 12 x 10(-3) M and fast response time within 7s. Due to the selective permeability of PMPD, the enzyme electrode also shows good anti-interference to uric acid and ascorbic acid. The Michaelis-Menten constant km and the maximum current density imax of the enzyme electrode were 9.34 x 10(-3) M and 917.43 microA cm(-2), respectively. Furthermore, this glucose biosensor also has good stability and reproducibility.  相似文献   

13.
Ratiometric measurements with FRET-based biosensors in living cells using a single fluorescence excitation wavelength are often affected by a significant ion sensitivity and the aggregation behavior of the FRET pair. This is an important problem for quantitative approaches. Here we report on the influence of physiological ion concentration changes on quantitative ratiometric measurements by comparing different FRET pairs for a cAMP-detecting biosensor. We exchanged the enhanced CFP/enhanced YFP FRET pair of an established Epac1-based biosensor by the fluorophores mCerulean/mCitrine. In the case of enhanced CFP/enhanced YFP, we showed that changes in proton, and (to a lesser extent) chloride ion concentrations result in incorrect ratiometric FRET signals, which may exceed the dynamic range of the biosensor. Calcium ions have no direct, but an indirect pH-driven effect by mobilizing protons. These ion dependences were greatly eliminated when mCerulean/mCitrine fluorophores were used. For such advanced FRET pairs the biosensor is less sensitive to changes in ion concentration and allows consistent cAMP concentration measurements under different physiological conditions, as occur in metabolically active cells. In addition, we verified that the described FRET pair exchange increased the dynamic range of the FRET efficiency response. The time window for stable experimental conditions was also prolonged by a faster biosensor expression rate in transfected cells and a greatly reduced tendency to aggregate, which reduces cytotoxicity. These properties were verified in functional tests in single cells co-expressing the biosensor and the 5-HT(1A) receptor.  相似文献   

14.
Li C  Han J  Ahn CH 《Biosensors & bioelectronics》2007,22(9-10):1988-1993
New flexible biosensors on a spirally rolled micro tube have been designed, fabricated and characterized for microcatheter-based cardiovascular in vivo monitoring. With this new microfabrication method, sensors, wires and circuits can be fabricated first on the flexible polymer substrate (Kapton film) and then rolled spirally to make micro tubes with different diameters. This approach provides a unique method for mounting multiple sensors on both the inside and outside the tube. So, the new spirally rolled polymer tube flexibly conceives physical, biomedical and physiological microsensors, elevating most problems arisen from wiring and assembling of microsensors in conventional microcatheters. As a demonstration vehicle, we fabricated glucose biosensors on the 25 microm thick Kapton film first, then the film was spirally rolled to make a polymer micro tube with the glucose sensors on the inside wall of the tube. To verify the performance of the spirally rolled glucose biosensor, we characterized it both in a planar unrolled and rolled conditions and compared their performances. The spirally rolled glucose sensors showed good performance in the typical glucose concentration range in human blood from 60 mg/dL to 120 mg/dL with different rolled diameters at different working temperature.  相似文献   

15.
This review introduces newdevelopments in a technique for measuring the movement of ions acrossthe plasma membrane. With the use of a self-referencing ion-selective(Seris) probe, transport mechanisms can be studied on a variety ofpreparations ranging from tissues to single cells. In this paper weillustrate this versatility with examples from the vas deferens andinner ear epithelium to large and small single cells represented bymouse single-cell embryos and rat microglia. Potassium and hydrogen ionfluxes are studied and pharmacological manipulation of the signals arereported. The strengths of the self-referencing technique are reviewedwith regard to biological applications, and the expansion ofself-referencing probes to include electrochemical and enzyme-based sensors is discussed.

  相似文献   

16.
Genetically constructed microbial biosensors for measuring organic pollutants are mostly applied in aqueous samples. Unfortunately, the detection limit of most biosensors is insufficient to detect pollutants at low but environmentally relevant concentrations. However, organic pollutants with low levels of water solubility often have significant gas-water partitioning coefficients, which in principle makes it possible to measure such compounds in the gas rather than the aqueous phase. Here we describe the first use of a microbial biosensor for measuring organic pollutants directly in the gas phase. For this purpose, we reconstructed a bioluminescent Pseudomonas putida naphthalene biosensor strain to carry the NAH7 plasmid and a chromosomally inserted gene fusion between the sal promoter and the luxAB genes. Specific calibration studies were performed with suspended and filter-immobilized biosensor cells, in aqueous solution and in the gas phase. Gas phase measurements with filter-immobilized biosensor cells in closed flasks, with a naphthalene-contaminated aqueous phase, showed that the biosensor cells can measure naphthalene effectively. The biosensor cells on the filter responded with increasing light output proportional to the naphthalene concentration added to the water phase, even though only a small proportion of the naphthalene was present in the gas phase. In fact, the biosensor cells could concentrate a larger proportion of naphthalene through the gas phase than in the aqueous suspension, probably due to faster transport of naphthalene to the cells in the gas phase. This led to a 10-fold lower detectable aqueous naphthalene concentration (50 nM instead of 0.5 micro M). Thus, the use of bacterial biosensors for measuring organic pollutants in the gas phase is a valid method for increasing the sensitivity of these valuable biological devices.  相似文献   

17.
A ferricyanide mediated microbial biosensor for ethanol detection was prepared by surface modification of a glassy carbon electrode. The selectivity of the whole Gluconobacter oxydans cell biosensor for ethanol determination was greatly enhanced by the size exclusion effect of a cellulose acetate (CA) membrane. The use of a CA membrane increased the ethanol to glucose sensitivity ratio by a factor of 58.2 and even the ethanol to glycerol sensitivity ratio by a factor of 7.5 compared with the use of a dialysis membrane. The biosensor provides rapid and sensitive detection of ethanol with a limit of detection of 0.85 microM (S/N=3). The selectivity of the biosensor toward alcohols was better compared to previously published enzyme biosensors based on alcohol oxidase or alcohol dehydrogenases. The biosensor was successfully used in an off-line monitoring of ethanol during batch fermentation by immobilized Saccharomyces cerevisiae cells with an initial glucose concentration of 200 g l(-1).  相似文献   

18.
High blood glucose levels are the main feature of diabetes. However, the underlying mechanism linking high glucose concentration to diabetic complications is still not fully elucidated, particularly with regard to human physiology. Excess of glucose is likely to trigger a metabolic response depending on the cell features, activating deleterious pathways involved in the complications of diabetes. In this study, we aim to elucidate how acute and prolonged hyperglycaemia alters the biology and metabolism in human fibroblasts and endothelial cells.We found that hyperglycaemia triggers a metabolic switch from oxidative phosphorylation to glycolysis that is maintained over prolonged time. Moreover, osmotic pressure is a major factor in the early metabolic response, decreasing both mitochondrial transmembrane potential and cellular proliferation. After prolonged exposure to hyperglycaemia we observed decreased mitochondrial steady-state and uncoupled respiration, together with a reduced ATP/ADP ratio. At the same time, we could not detect major changes in mitochondrial transmembrane potential and reactive oxygen species.We suggest that the physiological and metabolic alterations observed in healthy human primary fibroblasts and endothelial cells are an adaptive response to hyperglycaemia. The severity of metabolic and bioenergetics impairment associated with diabetic complications may occur after longer glucose exposure or due to interactions with cell types more sensitive to hyperglycaemia.  相似文献   

19.
Summary The Exactech blood glucose biosensor has been used successfully to measure glucose concentrations in fermentation broths. A highly sensitive linear calibration was obtained between the glucose concentration and the biosensor reading, which correlated well with a Reducing Sugar Assay.  相似文献   

20.
Effect of glucose feeding on net transport of plasma free fatty acids   总被引:4,自引:0,他引:4  
The effect of a single glucose feeding upon the net inflow and outflow transport of plasma free fatty acids (FFA) has been studied in 75 unanesthetized rats. The animals were fasted for 22 +/- 2 hr; then 50 rats were refed 2 ml of 50% glucose by gastric intubation. At 0, 10-15, and 30-35 min after glucose refeeding, the rats were injected with palmitate-1-(14)C complexed to rat serum. The tracer dose included (131)I-labeled albumin. Plasma FFA concentration, (131)I concentration, and FFA-(14)C were measured at five time intervals after injection of the tracer dose. From these data the irreversible disposal rate, or net outflow transport, and the net inflow transport of plasma FFA were calculated. Estimations were based upon a special case of a general solution for measuring net inflow and outflow transport of a circulating metabolite. The general solution is independent of the number of compartments, how they are interconnected, the number of nonradioactive inflows, and where the inflows enter the system. Net inflow = net outflow transport = 7.6 micro eq/min in the fasted state and 3.5 micro eq/min in the new steady state that is reached 30-40 min after glucose refeeding. A very slight imbalance between the rates of net inflow and outflow transport could account for the rapid fall in plasma FFA concentration that results from a single glucose feeding. Theoretical and practical problems associated with studying inflow and outflow transport by means of the technique using a single injection of racer are discussed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号