首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A rapid and sensitive method using liquid chromatography–tandem mass spectrometry (LC–MS/MS) for simultaneous determination of doxazosin and verapamil in human serum has been developed. Trimipramine-d3 as an isotopic labelled internal standard was used for quantification. Serum samples were prepared by simple liquid–liquid extraction with mixture of tert butyl methyl ether and ethyl acetate (1:1, v:v). The analytes and internal standard were separated on C18 column using an isocratic elution with 5 mM ammonium formate with 0.02% formic acid and 0.02% formic acid in acetonitrile (55:45, v:v) at a flow rate of 1.1 mL/min. Positive TurboIonSpray mass spectrometry was used with multiple reaction monitoring of the transitions at: m/z 455.3 → 165.2 and 150.2 for verapamil, m/z 452.2 → 344.4 and 247.4 for doxazosin, m/z 298.2 → 103.1 for trimipramine-d3. Linearity was achieved between 1 and 500 ng/mL (R2 ≥ 0.997) for both analytes. An extensive pre-study method validation was carried out in accordance with FDA guidelines. This assay was successfully applied to determine the serum concentrations of doxazosin and verapamil in suspect non-compliance patients.  相似文献   

2.
A simple, rapid and sensitive liquid chromatography/tandem mass spectrometric (LC/MS/MS) analytical method was developed for quantification of Hsp90 inhibitor PF-04928473 in human plasma, following administration of its prodrug, PF-04929113. Sample processing involved protein precipitation by addition of 0.4 mL of methanol containing internal standard (PF-04972487) to 50 μL volume of plasma sample. Chromatographic separation of PF-04928473 and PF-04972487 was achieved on a Phenomenex® Luna C18(2) (2.0mm × 50 mm, 5 μm) column using a gradient elution method with mobile phase solvents: methanol containing 0.1% formic acid and 0.1% formic acid at a flow rate of 0.25 mL/min. Detection was performed in electrospray positive ionization mode, monitoring the ion transitions from m/z 465.1 → 350.1 (PF-04928473) and m/z 447.0 → 329.1 (PF-04972487). The retention times for PF-04928473 and PF-04972487 were 1.86 and 2.85 min, respectively. Calibration curves were generated in the range of 2–2000 ng/mL. The accuracy and precision ranged from 94.1 to 99.0% and 86.7 to 97.6%, respectively, which were calculated using quality control samples of three different concentrations analyzed in quintuplicate on four different days.  相似文献   

3.
A rapid, simple and sensitive HPLC–ESI–MS/MS method was developed for the simultaneous determination of capsaicin and dihydrocapsaicin in rat plasma. Plasma samples containing capsaicin, dihydrocapsaicin and phenacetin (internal standard) were prepared based on a simple protein precipitation by the addition of two volumes of acetonitrile. The analytes and internal standard were separated on a Zorbax SB-C18 column (3.5 μm, 2.1 mm × 100 mm) with mobile phase of acetonitrile/water (55:45, v/v) containing 0.1% formic acid (v/v) at a flow rate of 0.2 mL/min with an operating temperature of 25 °C. Quantification was performed on a triple quadrupole mass spectrometer equipped with electrospray ionization (ESI) source by selected reaction monitoring (SRM) of the transitions at m/z 306–137 for capsaicin, m/z 308–137 for dihydrocapsaicin and m/z 180–110 for the IS. Linear detection responses were obtained for capsaicin and dihydrocapsaicin ranging from 1 to 500 ng/mL and the lower limits of quantitation (LLOQs) for the two compounds were 1 ng/mL. The intra- and inter-day precisions (R.S.D.%) were within 9.79% for the two analytes, while the deviations of assay accuracies were within ±10.63%. The average recoveries of the analytes were greater than 89.88%. The analytes were proved to be stable during all sample storage, preparation and analytic procedures. The method was successfully applied to the pharmacokinetic studies of capsaicin and dihydrocapsaicin in rats after subcutaneous administration of capsaicin (natural, containing 65% capsaicin and 35% dihydrocapsaicin).  相似文献   

4.
5.
A rapid, specific, and sensitive method utilizing reversed-phase ultra-performance liquid chromatography tandem mass spectrometry (UPLC–MS/MS) was developed and validated to determine finasteride levels in human plasma. The plasma samples were prepared by liquid–liquid extraction with ethyl acetate, evaporation, and reconstitution. MS/MS analyses were performed on a triple–quadrupole tandem mass spectrometer by monitoring protonated parent → daughter ion pairs at m/z 373 → 305 for finasteride and m/z 237 → 194 for carbamazepine (internal standard, IS). The method was validated with respect to linearity, recovery, specificity, accuracy, precision, and stability. The method exhibited a linear response from 0.1 to 30 ng/mL (r2 > 0.998). The limit of quantitation for finasteride in plasma was 0.1 ng/mL. The relative standard deviation (RSD) of intra- and inter-day measurements was less than 15% and the method was accurate within −6.0% to 2.31% at all quality-control levels. The mean extraction recovery was higher than 83% for finasteride and 84% for the IS. Plasma samples containing finasteride were stable under the three sets of conditions tested and the processed samples were stable up to 29 h in an autosampler at 5 °C. Detection and quantitation of both analytes within 3 min make this method suitable for high-throughput analyses. The method was successfully applied to a pharmacokinetic study of finasteride in healthy volunteers following oral administration.  相似文献   

6.
A rapid, sensitive and simple high performance liquid chromatography–tandem mass spectrometry (HPLC–MS/MS) method was developed for determination of cefazedone in human plasma using metronidazole as internal standard (IS). The chromatographic separation was achieved on an Ultimate XB-CN column (2.1 mm × 150 mm, 5 μm) with an isocratic mobile phase of acetonitrile and 20 mM ammonium acetate in 0.1% formic acid in water (15:85, v/v). Detection was performed using electrospray ionization in positive ion multiple reaction-monitoring mode (SRM), monitoring the transitions m/z 548.2 → 344.1 for cefazedone and m/z 172.2 → 128.1 for IS. Calibration curves were linear over a wide range of 0.20–401.12 μg/mL for cefazedone in plasma. The lower limit of quantification (LLOQ) was 0.20 μg/mL. The intra- and inter-day precisions were less than 7.2%. The average recovery of cefazedone was 90.8–91.0%. The validated method was successfully applied to the pharmacokinetic study of cefazedone in Chinese healthy volunteers following intravenous (IV) administration of 500, 1000 and 2000 mg cefazedone injection.  相似文献   

7.
A sensitive and accurate ultra-performance liquid chromatography electrospray ionization tandem mass spectrometry (UPLC–ESI-MS/MS) method was developed and validated for the simultaneous determination of vitexin-4″-O-glucoside (VGL), vitexin-2″-O-rhamnoside (VRH), rutin (RUT) and vitexin (VIT) in rat plasma after intravenous administration of hawthorn leaves flavonoids (HLF). Following protein precipitation by methanol, the analytes were separated on an ACQUITY UPLC BEH C18 column packed with 1.7 μm particles by gradient elution using a mobile phase composed of acetonitrile and water (containing 0.1% formic acid) at a flow rate of 0.20 mL/min. The analytes and diphenhydramine (internal standard, IS) were detected in the multiple reaction monitoring (MRM) mode by means of an electrospray ionization (ESI) interface (m/z 292.96 for vitexin-4″-O-glucoside, m/z 293.10 for vitexin-2″-O-rhamnoside, m/z 299.92 for rutin, m/z 310.94 for vitexin and m/z 166.96 for IS). The calibration curve was linear over the range 10–40,000 ng/mL for vitexin-4″-O-glucoside, 10–50,000 ng/mL for vitexin-2″-O-rhamnoside, 8–1000 ng/mL for rutin and 16–2000 ng/mL for vitexin. The intra- and inter-run precisions (relative standard deviation, RSD) of these analytes were all within 15% and the accuracy (the relative error, RE) ranged from −10% to 10%. The stability experiment indicated that the four analytes in rat plasma samples and plasma extracts under anticipated conditions were stable. The developed method was applied for the first time to pharmacokinetic studies of the four bioactive compounds of hawthorn leaves flavonoids following a single intravenous administration of 20 mg/kg in rats.  相似文献   

8.
A highly sensitive liquid chromatography-tandem mass spectrometric (LC-MS/MS) method was developed for the determination of forsythiaside in rat plasma using epicatechin as internal standard. The analytes were extracted by solid-phase extraction and chromatographied on a C18 column eluted with a gradient mobile phase of acetonitrile and water both containing 0.2% formic acid. The detection was performed by negative ion electrospray ionization in multiple reaction monitoring mode, monitoring the transitions m/z 623 → 161 and m/z 289 → 109 for forsythiaside and epicatechin, respectively. The assay was linear over the concentration ranges of 2.0–50.0 and 50.0–5000.0 ng/mL with limits of detection and quantification of 0.2 and 1.0 ng/mL, respectively. The precision was <10.8% and the accuracy was >91.9%, and extraction recovery ranged from 81.3% to 85.0%. This method was successfully applied to a pharmacokinetic study of forsythiaside in rats after intravenous (20 mg/kg) and oral (100 mg/kg) administration, and the result showed that the compound was poorly absorbed with an absolute bioavailability being approximately 0.5%.  相似文献   

9.
Eleven polyphenols, classified as flavonoid glycosides, flavonoid aglycones, and phenolic acids, are important bioactive components in the capitula of Coreopsis tinctoria (CCT). Nevertheless, their full pharmacokinetic profiles have not been demonstrated simultaneously. Therefore, a liquid chromatography – tandem mass spectrometry (LC/MS/MS) method was developed in the present work and used it to study the pharmacokinetics of these 11 compounds. We performed LC/MS/MS with a gradient mobile phase composed of water containing 0.1 % formic acid and acetonitrile containing 0.1 % formic acid on a Proshell 120 SB C18 column (2.1 mm×100 mm, 2.7 μm). We achieved a good chromatographic peak shape, resolution, and mass signal response, and multiple reaction monitoring facilitated the simultaneous detection of 11 analytes. In addition, we validated the selectivity, correlation coefficient, precision, extraction recovery, matrix effects, and stability of the LC/MS/MS method to be acceptable for 11 analytes in rat plasma. Subsequently, rats were orally administered with 50 % ethanol eluent of CCT (ECCT). Nine of 11 polyphenols were absorbed quickly (except for QCD and TCA), and their plasma levels peaked within 40 min. The exposure and Cmax values of flavonoid glycosides and phenolic acids were lower than those of flavonoid aglycones. This is the first report to demonstrate the pharmacokinetics of 11 polyphenols in ECCT, which may play an important role in future studies of the bioactive components of ECCT and their bioactive mechanisms.  相似文献   

10.
A novel, sensitive and reliable liquid chromatography–tandem mass spectrometric (LC–MS/MS) method was developed and validated for the determination of belinostat (PXD101) in human plasma. Oxamflatin was used as the internal standard. Liquid–liquid extraction of the plasma sample was performed using tert-butyl methyl ether as the organic solvent. Chromatographic separation was achieved on a BDS Hypersil C18 column (2.1 mm × 100 mm, 5 μm) using gradient elution mode using 0.05% formic acid in water and 0.05% formic acid in acetonitrile as solvents A and B, respectively, 60/40. The run time was 6 min. The mass spectrometer was operated under a positive electrospray ionization condition and a multiple reaction monitoring mode. An excellent linear calibration was achieved in the range of 0.5–1000 ng/mL. An average recovery of belinostat for four quality controls was 72.6% and the recovery of the internal standard at 1000 ng/mL was 67.8%. The intra-day and inter-day precisions for belinostat were ≤8.0 and ≤10.3%, respectively, and their accuracy ranged from 100.2 to 106.7%. No significant matrix effect was identified. In analysis of patient samples, belinostat glucuronide was identified and baseline separated from belinostat. This well-validated assay has been applied for quantification of belinostat in plasma samples within 24 h after the start of infusion for Asian hepatocellular carcinoma patients in a dose escalation study.  相似文献   

11.
A rapid, simple and sensitive method was developed for the determination of para-aminohippuric acid (PAH) in rat plasma using liquid chromatography tandem mass spectrometry (LC-MS-MS). Acetaminophen was used as the internal standard. Chromatographic separation was performed using a Symmetry C18 column and the mobile phase was composed of A: 2 mM ammonium formate and 0.1% formic acid in water and B: 2 mM ammonium formate and 0.1% formic acid in acetonitrile (ACN) (A:B, 30:70, v/v). Detection was performed on a triple–quadrupole tandem mass spectrometer using positive ion mode electrospray ionization (ESI) in the multiple reaction monitoring (MRM) mode. The MS/MS ion transitions monitored were m/z 195.2 → 120.2 and 152.1 → 110.1 for PAH and acetaminophen, respectively. Good linearity is observed over the concentration range of 0.1–500 μg/ml. The method was proved to be accurate and reliable and was applied to a pharmacokinetic study in rat.  相似文献   

12.
A fast and sensitive HPLC–APCI-MS/MS method was developed for the determination of ergosta-4,6,8(14),22-tetraen-3-one (ergone) in rat plasma. The plasma sample containing ergone and ergosterol (internal standard) were simply treated with acetone to precipitate and remove proteins and the isolated supernatants were directly injected into the HPLC–APCI-MS/MS system. Chromatographic separation was performed on a 1.8 μm Zorbax SB-C18 column (100 mm × 3.0 mm) with a 97:3 (v/v) mixed solution of methanol and 0.1% aqueous formic acid being used as mobile phase. Quantification was performed by multiple selected reactions monitoring (MRM) of the transitions with (m/z)+ 393–268 for ergone and (m/z)+ 379–69 for the IS. The method was validated in the concentration range of 5–1600 ng/mL for ergone. The precision of the assay (RSD%) was less than 10.5% at all concentrations levels within the tested range and adequate accuracy, and the limit of detection was 1.5 ng/mL. The absolute recoveries of both ergone and ergosterol from the plasma were more than 95%. The developed method has been successfully applied to the pharmacokinetic study of the drug in SD rats.  相似文献   

13.
A rapid, sensitive and specific method for the determination of cepharanthine in human plasma using high performance liquid chromatography coupled with tandem mass spectrometry (HPLC–MS/MS) was described. Cepharanthine and the internal standard (I.S.), telmisartan, were extracted from human plasma by methanol to precipitate the protein. A centrifuged upper layer was then evaporated and reconstituted with 100 μL methanol. Chromatographic separation was performed on an AGILENT XDB-C8 column (150 mm × 2.1 mm, 5.0 μm, Agilent, USA) using a gradient mobile phase with 1 mmol/L ammonium acetate in water with 0.05% formic acid and methanol. Detection and quantitation was performed by MS/MS using electrospray ionization (ESI) and multiple reaction monitoring (MRM) in the positive ion mode. The most intense [M+H]+ MRM transition of cepharanthine at m/z 607.3 → 365.3 was used for quantitation and the transition at m/z 515.5 → 276.4 was used to monitor telmisartan. The calibration curve was linear within the concentration range of 0.5–200.0 ng/mL (= 0.9994). The limit of quantification (LOQ) was 0.5 ng/mL. The extraction recovery was above 81.1%. The accuracy was higher than 92.3%. The intra- and inter-day precisions were less than 9.66%. The method was accurate, sensitive and simple and was successfully applied to a pharmacokinetic study after single intravenous administration of 50 mg cepharanthine in 12 healthy Chinese volunteers.  相似文献   

14.
A sensitive and selective liquid chromatographic-tandem mass spectrometric (LC-MS/MS) method was developed for the determination of serial chiral novel anticholinergic compounds of phencynonate in rat plasma. After a simple protein-precipitation using methanol, the post-treatment samples were separated on a CAPCELL UG120 column with a mobile phase of a mixture of methanol and water (35:65) containing 0.1% formic acid. The serial chiral analytes and internal standard (IS) were all detected by the use of selected reaction monitoring mode (SRM). The method of all serial chiral analytes developed was validated in rat plasma with a daily working range of 0.5-100 ng/ml with correlation coefficient, R(2) > or = 0.99 and a sensitivity of 0.5 ng/ml as lower limit of quantification, respectively. This method was fully validated for the accuracy, precision and stability studies for all serial chiral analytes. The method proved to be accurate and specific, and was applied to the pharmacokinetic study of serial chiral novel anticholinergic compounds of phencynonate in rat plasma.  相似文献   

15.
A sensitive, specific, and rapid liquid chromatography-mass spectrometry (LC-MS) method was developed and validated for analysis of lasiodonin, oridonin, ponicidin, and rabdoternin A in rat plasma using sulfamethoxazole as an internal standard (IS). The plasma samples were pretreated and extracted by liquid-liquid extraction. Chromatographic separation was performed on a C18 column with linear gradient elution using water and methanol, both of which were acidified with 0.1% aqueous formic acid, at a flow rate of 0.8 ml/min. Detection was accomplished by scanning with multiple reaction monitoring (MRM) via an electrospray ionization (ESI) source. Higher sensitivity was achieved by setting three scanning periods in a novel detection mode. The optimized mass transition ion pairs (m/z) for quantitation were 365.3/347.3 for lasiodonin and oridonin, 361.2/343.2 for ponicidin, 363.2/283.1 for rabdoternin A, and 254.1/156.0 for IS. The total run time was 13.50 min between injections. The specificity, linearity, accuracy, precision, recovery, matrix effect, and several stabilities were validated for all analytes in the rat plasma samples. In conclusion, the validation results demonstrate that this method is robust and specific. The proposed method was further applied to investigate the pharmacokinetics of all analytes after a single oral administration of Isodon rubescens extract to rats.  相似文献   

16.
A rapid, sensitive and specific method was developed and validated using liquid chromatography-tandem mass spectrometry (LC/MS/MS) for determination of gefitinib in human plasma and mouse plasma and tissue. Sample preparation involved a single protein precipitation step by the addition of 0.1 mL of plasma or a 200 mg/mL tissue homogenate diluted 1/10 in human plasma with 0.3 mL acetonitrile. Separation of the compounds of interest, including the internal standard (d8)-gefitinib, was achieved on a Waters X-Terra C18 (50 mm x 2.1 mm i.d., 3.5 microm) analytical column using a mobile phase consisting of acetonitrile-water (70:30, v/v) containing 0.1% formic acid and isocratic flow at 0.15 mL/min for 3 min. The analytes were monitored by tandem mass spectrometry with electrospray positive ionization. Linear calibration curves were generated over the range of 1-1000 ng/mL for the human plasma samples and 5-1000 ng/mL for mouse plasma and tissue samples with values for the coefficient of determination of > 0.99. The values for both within- and between-day precision and accuracy were well within the generally accepted criteria for analytical methods (< 15%). This method was subsequently used to measure concentrations of gefitinib in mice following administration of a single dose of 150 mg/kg intraperitoneally and in cancer patients receiving an oral daily dose of 250 mg.  相似文献   

17.
A method for the quantitative analysis of cudratricusxanthone B (CXB) in rat plasma by high performance liquid chromatography–electrospray ionization-tandem mass spectrometry (HPLC–ESI-MS/MS) has been developed and validated. The method involved liquid–liquid extraction from plasma, simple chromatographic conditions on a Venusil XBP-PH C18 column with the mobile phase of 0.5% formic acid in methanol, and mass spectrometric detection using an API-3000 instrument. Multiple reaction monitoring (MRM) mode was used to monitor precursor/product ion transitions of m/z 397.1/285.0 for CXB and m/z 381.6/269.2 for the internal standard (I.S.) cudraxanthone H. The standard curves were linear over the concentration range of 1–500 ng/mL for CXB in rat plasma. The intra- and inter-batch accuracy for CXB at four concentrations was 89.4–99.5% and 89.4–100.8%, respectively. The RSDs were less than 7.92%. The lower limit of quantification for CXB was 1.0 ng/mL using 100 μL of plasma. The average extraction recoveries of CXB ranged from 80.1 to 95.4% at the concentrations of 2, 50 and 500 ng/mL, respectively. This method was successfully applied to the pharmacokinetic study after an intravenous administration of CXB in male Sprague–Dawley (SD) rats.  相似文献   

18.
The alkaloids from Piper longum L. showed protective effects on Parkinson's disease models in our previous study and piperine and piperlonguminine were the two main constituents in the alkaloids. The present study aimed at developing a rapid, sensitive, and accurate UFLC-ESI-MS/MS method and validating it for the simultaneous determination of piperine and piperlonguminine in rat plasma using terfenadine as the internal standard. The analytes and internal standard (IS) were extracted from rat plasma using a simple protein precipitation by adding methanol/acetonitrile (1:1, v/v). A Phenomenex Gemini 3 u C18 column (20 mm × 2.00 mm, 3 μm) was used to separate the analytes and IS using a gradient mode system with a mobile phase consisting of water with 0.1% formic acid (mobile phase A) and acetonitrile with 0.1% formic acid (mobile phase B) at a flow rate of 0.4 mL/min and an operating column temperature of 25°C. The total analytical run time was 4 min. The detection was performed using the positive ion electrospray ionization (ESI) in multiple reaction monitoring (MRM) mode with transitions at m/z 286.1-201.1 for piperine, m/z 274.0-201.1 for piperlonguminine, and m/z 472.4-436.4 for the IS. The calibration curves were both linear (r>0.995) over a concentration range of 1.0 to 1000 ng/mL; the lower limit of quantification (LLOQ) was 1.0 ng/mL for both piperine and piperlonguminine. The intra-day and inter-day precisions (RSD %) were <12.1%, accuracies ranged from 86.6 to 120%, and recoveries ranged from 90.4 to 108%. The analytes were proven stable in the short-term, long-term, and after three freeze-thaw cycles. The method was successfully applied to pharmacokinetic studies of piperine and piperlonguminine in rats after oral administration of alkaloids from P. longum L.  相似文献   

19.
A precise and sensitive liquid chromatography–tandem mass spectrometry (LC–MS/MS) method for simultaneous determination of vinpocetine (VP) and its primary metabolite, apovincaminic acid (AVA), in rat plasma was developed and validated. The analytes and the internal standard-dimenhydrinate were extracted from 50 μL aliquots of rat plasma via solid–liquid extraction. Chromatographic separation was achieved in a run time of 3.5 min on a C18 column under isocratic conditions. Detection of analytes and IS was done by tandem mass spectrometry, operating in positive ion and multiple reaction monitoring (MRM) acquisition mode. The protonated precursor to product ion transitions monitored for VP, AVA and IS were m/z 351.4 → 280.2, 323.2 → 280.2 and 256.2 → 167.3 respectively. The method was fully validated for its sensitivity, selectivity, accuracy and precision, matrix effect, stability study and dilution integrity. A linear dynamic range of 0.5–500 ng/mL for both VP and AVA was evaluated with mean correlation coefficient (r) of 0.9970 and 0.9984 respectively. The precision of the assay (RSD%) was less than 8.55% at all concentrations levels for both VP and AVA. This method was successfully applied to a pharmacokinetic study of VP in rats after intravenous (1 mg/kg) and oral (1 mg/kg) administration.  相似文献   

20.
Flavanoid kaempferol is mainly present as glucuronides and sulfates in rat plasma, and small amounts of the intact aglycone are also detected. In the this study, a rapid, specific and sensitive liquid chromatography–electrospray ionization-tandem mass spectrometry method (HPLC–MS/MS) was developed and validated for determination of kaempferol and its major metabolite glucuronidated kaempferol in rat plasma. A liquid–liquid extraction with acetic ether was involved for the extraction of kaempferol and internal standard. Analytes were separated on a C18 column (150 mm × 2.1 mm, 4.5 μm, Waters Corp.) with isocratic elution at a flow-rate of 0.3 ml min−1. The mobile phase was consisted of 0.5% formic acid and acetonitrile (50:50, v/v). The Quattro Premier HPLC–MS/MS was operated under the multiple reaction-monitoring mode (MRM) using the electrospray ionization technique. The method was validated according to the FDA guidelines for validation of bioanalytical method. The validated method was successfully applied to the study of the pharmacokinetics in rats after oral administration of kaempferol with different doses.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号