首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
An HPLC–MS–MS method for the quantitative analysis of flunitrazepam in human serum was established. The method features a very simple liquid–liquid extraction, the use of a standard 4-mm HPLC column, isocratic elution using a buffer-free solvent, short retention times in connection with good peak resolution and the sensitivity and selectivity of an ion trap MS–MS detector. The procedure enables unambiguous identification of analytes by their product ion spectra, as well as sensitive quantitation (limit of quantitation for flunitrazepam=0.5 ng/ml). This feature was used for the confirmation of HPLC–UV results for nitrazepam.  相似文献   

2.
An ion-paring HPLC–MS–MS method with positive ion mode electrospray ionization has been developed to simultaneously quantify Ziagen, carbovir monophosphate, carbovir diphosphate and carbovir triphosphate. N′,N′-Dimethylhexylamine was used as the ion-pairing agent. The presence of this ion-pairing agent allowed the retention and separation of the four compounds on a reversed-phase HPLC column as well as the detection of the nucleotides with positive ion mode electrospray ionization. The limits of detection were found to be better than 25 nM for all the analytes. Calibration curves of the analytes showed excellent linearity over the range of 25 nM to 5 μM. The relative standard deviations and accuracies for replicate analyses of quality control samples were less than 15%. The method has been successfully applied to the analysis of these compounds in human liver cells treated with Ziagen.  相似文献   

3.
A liquid chromatography–electrospray ionization tandem mass spectrometric method was developed for the simultaneous determination of losartan and its major active metabolite, EXP-3174, in human plasma. The two analytes and the internal standard (DuP-167) were extracted from plasma under acidic conditions by using solid-phase extraction cartridges containing a sorbent of copolymer, poly(divinylbenzene-co-N-vinylpyrrolidone). The analytes were separated by LC equipped with a reversed-phase C18 column, and introduced into the mass spectrometer via the electrospray ion source with pneumatically-assisted nebulization. For LC–MS–MS samples, an isocratic mobile phase consisting of [0.1% triethylamine–0.1% acetic acid (pH 7.1)]–acetonitorile (65:35, v/v) was used, and the assay was monitored for the negative fragment ions of the analytes. The method demonstrated linearity from 1 to 1000 ng/ml for both losartan and EXP-3174. The limit of quantification for both compounds in plasma was 1 ng/ml. This assay method may be useful for the measurement of levels of the two compounds in clinical studies of losartan.  相似文献   

4.
A rugged, high-throughput HPLC–MS–MS-based method, suitable for quantitation of norepinephrine (NE) in urine, has been developed. A rapid, batch-mode procedure utilizes alumina to isolate NE and its deuterated internal standard from urine. After release of NE, using dilute formic acid, samples are analyzed by isocratic reversed-phase ion-pair HPLC, with electrospray ionization (ESI) and MS–MS detection. The ion-pair reagent, heptafluorobutyric acid, is compatible with the ESI interface and permits use of mobile phases with relatively high methanol content, enhancing ESI sensitivity. Furthermore, no significant drop in sensitivity is observed throughout more than 15 h of instrument operation. The selectivity of this approach permitted simplification of the extraction procedure and reduced run times (under 4 min), making single batch-run sizes of more than 200 samples practical. The lower limit of quantitation is 5 ng per 0.5 ml sample, with analytical recoveries of 97–100% and overall method precision of better than 4% relative standard deviation verified up to 500 ng ml−1. This method was initially applied to study the diurnal rhythm in sympathetic nervous system activity of spontaneously hypertensive rats.  相似文献   

5.
More than hundred pharmaceuticals, drugs of abuse or doping agents have been reported to be detectable in human hair. This article reviews the analysis of 90 drugs and drug metabolites by chromatographic procedures, including the pretreatment steps, the extraction methods, the reported limits of detection and the measured concentrations in real human hair samples. Some progress is observed in the detection of low dose drugs, like fentanyl or flunitrazepam. The general tendency in the last years, to highly sophisticated techniques (GC–MS–NCI, HPLC–MS, GC–MS–MS) illustrates well this constant fight for sensitivity. Some new findings, based on the recent experience of the authors, are also added.  相似文献   

6.
The ability to simultaneously quantitate cocaine and its 12 metabolites from pregnant rat blood, amniotic fluid, placental and fetal tissue homogenates aids in elucidating the metabolism and distribution of cocaine. An efficient extraction method was developed to simultaneously recover these 13 components using underivatized silica solid-phase extraction (SPE) cartridges. The overall recoveries for cocaine and its metabolites were studied from pregnant rat blood (47–100%), amniotic fluid (61–100%), placental homogenate (31–83%), and fetal homogenate (39–87%). Extraction of the samples using silica is not classical SPE, but rather allows for the concentration of the sample into a small volume prior to injection and the removal of the proteins due to their strong interaction with the active silica surface. A positive ion mode electrospray ionization liquid chromatography–tandem mass spectrometry (LC–MS–MS) method was used and validated to simultaneously quantitate cocaine and 12 metabolites from these four biological matrices. A gradient elution method with a Zorbax XDB C8 reversed-phase column was used to separate the components. Multiple reaction monitoring (MRM) of a product ion arising from the corresponding precursor ion was used in order to enhance the selectivity and sensitivity of the method. Low background noise was observed from the complex biological matrices due to efficient SPE and the selectivity of the MRM mode. Linear calibration curves were generated from 0.01 to 2.50 ppm. The method also showed high intra-day (n=3) and inter-day (n=9) precision (% RSD) and accuracy (% error) for all components. The limits of detection (LODs) for the method ranged from 0.15 to 10 ppb. The LODs of cocaine and its major metabolites were less than 1 ppb from all four biological matrices. This method was applied to the study of the metabolism and distribution of cocaine in pregnant rats following intravenous infusion to a steady state plasma drug concentration. The following results were observed in the pregnant rat study: (1) the observations correlated strongly with the previous literature data on cocaine metabolism and distribution, (2) cocaine and norcocaine accumulated in the placenta, (3) arylhydroxylation of cocaine was a major metabolic pathway, (4) para-arylhydroxylation of cocaine was favored over meta-arylhydroxylation in rats and (5) accumulation of cocaine and its major metabolites was observed in the amniotic fluid.  相似文献   

7.
This work presents the development and the validation of an LC–MS–MS method with atmospheric pressure chemical ionization for the quantitative determination of levamisole, an anthelmintic for veterinary use, in porcine tissue samples. A liquid–liquid back extraction procedure using hexane–isoamylalcohol (95:5, v/v) as extraction solvent was followed by a solid-phase extraction procedure using an SCX column to clean up the tissue samples. Methyllevamisole was used as the internal standard. Chromatographic separation was achieved on a LiChrospher® 60 RP-select B (5 μm) column using a mixture of 0.1 M ammonium acetate in water and acetonitrile as the mobile phase. The mass spectrometer was operated in MS–MS full scanning mode. The method was validated for the analysis of various porcine tissues: muscle, kidney, liver, fat and skin plus fat, according to the requirements defined by the European Community. Calibration graphs were prepared for all tissues and good linearity was achieved over the concentration ranges tested (r>0.99 and goodness of fit <10%). Limits of quantification of 5.0 ng/g were obtained for the analysis of levamisole in muscle, kidney, fat and skin plus fat tissues, and of 50.0 ng/g for liver analysis, which correspond in all cases to half the MRLs (maximum residue limits). Limits of detection ranged between 2 and 4 ng/g tissue. The within-day and between-day precisions (RSD, %) and the results for accuracy fell within the ranges specified. The method has been successfully used for the quantitative determination of levamisole in tissue samples from pigs medicated via drinking water. Moreover the product ion spectra of the levamisole peak in spiked and incurred tissue samples were in close agreement (based on ion ratio measurements) with those of standard solutions, indicating the worthiness of the described method for pure qualitative purposes.  相似文献   

8.
A sensitive and selective method for the quantification of mycophenolate mofetil and its active metabolite mycophenolic acid in different human skin layers after dermal administration is presented. The skin layers were separated after in vitro penetration experiments and a methanolic extraction was performed. Positive ion electrospray HPLC–MS in selected ion monitoring mode was used to quantify the substances after isocratic separation by a C18 analytical column. The minimum detectable concentrations were 850 pg/ml for MMF and 1 ng/ml for MPA. The peak areas depended linearly on the concentration of both drugs over the range of 25–1000 ng/ml (r2≥0.996) with accuracy ≤9.8% and precision ≤13.2%. Total imprecision at quantification limits was 15.2% at 10 ng/ml and 16.3% at 1500 ng/ml for MMF and 15.1% at 21.0 ng/ml and 17.5% at 1300 ng/ml for MPA. This HPLC–MS method will be applicable to the profiling of MMF amounts in skin and its conversion to MPA after application of different formulations.  相似文献   

9.
A sensitive and specific assay aimed at measuring 8-oxo-7,8-dihydro-2′-deoxyguanosine (8-oxodGuo) has been developed by associating a reversed-phase liquid chromatographic separation with an electrospray tandem mass spectrometric detection. The HPLC–MS approach in the single ion monitoring (SIM) mode and the HPLC–MS/MS assay in the multiple reaction monitoring (MRM) mode have been compared, using isotopically labeled [M+4] 8-oxodGuo as the internal standard. The limit of detection of 8-oxodGuo was found to be around 5 pmol and 20 fmol for the HPLC–MS and HPLC–MS/MS methods, respectively. The HPLC–MS/MS assay is sensitive enough to allow the determination of the level of 8-oxodGuo in cellular liver DNA and in urine samples.  相似文献   

10.
Flavanoid kaempferol is mainly present as glucuronides and sulfates in rat plasma, and small amounts of the intact aglycone are also detected. In the this study, a rapid, specific and sensitive liquid chromatography–electrospray ionization-tandem mass spectrometry method (HPLC–MS/MS) was developed and validated for determination of kaempferol and its major metabolite glucuronidated kaempferol in rat plasma. A liquid–liquid extraction with acetic ether was involved for the extraction of kaempferol and internal standard. Analytes were separated on a C18 column (150 mm × 2.1 mm, 4.5 μm, Waters Corp.) with isocratic elution at a flow-rate of 0.3 ml min−1. The mobile phase was consisted of 0.5% formic acid and acetonitrile (50:50, v/v). The Quattro Premier HPLC–MS/MS was operated under the multiple reaction-monitoring mode (MRM) using the electrospray ionization technique. The method was validated according to the FDA guidelines for validation of bioanalytical method. The validated method was successfully applied to the study of the pharmacokinetics in rats after oral administration of kaempferol with different doses.  相似文献   

11.
A flunixin metabolite, a hydroxylated product, has been identified in camel urine and plasma samples using gas chromatography–mass spectrometry (GC–MS) and GC–MS–MS in the electron impact and chemical ionization modes. Its major fragmentation pattern has been verified by GC–MS–MS in daughter ion and parent ion scan modes. The method could detect flunixin and its metabolite in camel urine after a single intravenous dose of 2.2 mg of flunixin/kg body weight for 96 and 48 h, respectively, which increases the reliability of antidoping control analysis.  相似文献   

12.
A sensitive and specific assay of human plasma for the determination of (5α,7β,16β)-16[(4-chlorophenyl)oxy]-4,7-dimethyl-4-aza-andronstan-3-one (I), a selective inhibitor of human type 1 5α-reductase, has been developed. The method is based on high-performance liquid chromatography (HPLC) with tandem mass spectrometric (MS–MS) detection. The analyte (I) and internal standard, Proscar (II), were isolated from the basified biological matrix using a liquid–liquid extraction with methyl-tert.-butyl ether (MTBE). The organic extract was evaporated to dryness, the residue was reconstituted in mobile phase and injected into the HPLC system. The MS–MS detection was performed on a PE Sciex API III Plus tandem mass spectrometer using a heated nebulizer interface. Multiple reaction monitoring using the precursor→product ion combinations of m/z 430→114 and 373→305 was used to quantify I and internal standard (II), respectively. The assay was validated in the concentration range of 0.5 to 500 ng/ml in human plasma. The precision of the assay, expressed as coefficient of variation (C.V.), was less than 7% over the entire concentration range, with adequate assay specificity and accuracy. The HPLC–MS–MS method provided sufficient sensitivity to completely map the 24 h pharmacokinetic time-course following a single 0.5 mg dose of I.  相似文献   

13.
A sensitive and specific LC–MS–MS assay has been developed and validated for barnidipine (1-benzyl-3-pyrrolidinyl)methyl-2,6-dimethyl-4(m-nitrophenyl)-1,4-dihydropyridine-3,5-dicarboxylate). The assay involves a simple and rapid solid-phase extraction procedure. Sample analysis was on a Spherisorb S3ODS2 100 mm×2 mm I.D. column, with a Finnigan TSQ 7000 mass spectrometer, using an electrospray interface and selective reaction monitoring (SRM). The intra- and inter-day precision and accuracy, determined as the coefficient of variation and relative error, respectively, were 11.8% or less. The limit of quantitation was 0.03 ng/ml, and the calibration was linear between 0.03 and 3.0 ng/ml. The method has been used successfully for the measurement of over two thousand human plasma samples from pharmacokinetic clinical trials.  相似文献   

14.
We present fast LC–MS–MS analyses of multicomponent mixtures containing flavones, sulfonamides, benzodiazepines and tricyclic amines. Using a short microbore HPLC column with small particle size, five to eight compounds were partially resolved within 15 to 30 s. TurboIonSpray and atmospheric pressure chemical ionization interfaces were well suited to tolerate the higher eluent flow-rates of 1.2 to 2 ml/min. The methods were applied to biological sample matrices after clean-up using solid-phase or liquid–liquid extraction. Good precision and accuracy (average 8.9 and 97.7%, respectively) were achieved for the determination of tricyclic amines in human plasma. Benzodiazepines were determined in human urine with average precision of 9% and average accuracy of 95% for intra- and inter-assay. Detection limits in the low ng/ml range were obtained. An example for 240 injections per hour of demonstrated the feasibility of rapid LC–MS–MS analysis.  相似文献   

15.
A sensitive, specific, accurate and reproducible LC–MS–MS method was developed and validated for the simultaneous quantitation of the prodrug fosinopril and its active drug fosinoprilat in human serum. The method employed acidification of the serum samples to minimize the hydrolysis of fosinopril to fosinoprilat prior to purification by solid-phase extraction to isolate the two analytes and the two internal standards from human serum. The extracted samples were analyzed by turbo ionspray LC–MS–MS in the positive ion mode. Chromatography was performed on a polymer-based C18 column (Asahipak™ ODP PVA-C18, 2×50 mm) using gradient elution with methanol and 10 mM ammonium acetate, pH 5.5. The calibration curve, 1.17 to 300 ng/ml, was fitted to a weighted (l/x) linear regression model. Serum quality control (QC) samples used to gauge the accuracy and precision of the method were prepared at concentrations of 5.00, 100, 250 and 500 ng/ml of each analyte. The inter-assay accuracies were within 6% (DEV) for both analytes. The intra- and inter-assay precisions were within 7% and 11% (RSD), respectively, for both analytes. The hydrolysis of fosinopril to fosinoprilat during sample processing was ≤6%. This degree of conversion would cause little error in the analysis of post-dose serum samples since such samples are known to contain low levels of the prodrug compared to the drug.  相似文献   

16.
A sensitive LC–MS quantitation method of cetrorelix, a novel gonadotropin releasing hormone (GnRH) antagonist, was developed. Plasma and urine samples to which brominated cetrorelix was added as an internal standard (I.S.) were purified by solid-phase extraction with C8 cartridges. The chromatographic separation was achieved on a C18 reversed-phase column using acetonitrile–water–trifluoroacetic acid (35:65:0.1, v/v/v) as mobile phase. The mass spectrometric analysis was performed by electrospray ionization mode with negative ion detection, and the adduct ions of cetrorelix and I.S. with trifluoroacetic acid were monitored in extremely high mass region of m/z 1543 and 1700, respectively. The lower limit of quantitation was 1.00 ng per 1 ml of plasma and 2.09 ng per 2 ml of urine, and the present method was applied to the analysis of pharmacokinetics of cetrorelix in human during phase 1 clinical trial.  相似文献   

17.
A procedure for detecting and confirming 23 anabolic substances and/or metabolites has been developed using a GC–MS–MS ion trap system in full-scan mode. The process used to select the precursor ion, and the optimization of the system parameters used to obtain the daughter ion spectra, are explained. Urine samples were prepared using solid-phase extraction and enzymatic hydrolysis, and after TMS derivatives had been formed, they were injected into the mass spectrometer. This method permits confirmation of the presence of anabolic substances at low ng ml−1 levels without the need of further purification procedures on the samples. This procedure has been used on more than 2000 urine samples collected from sporting competitions and has made it possible to confirm more than 45 true positive cases which could not have been confirmed using routine GC–MS methods.  相似文献   

18.
A column-switching liquid chromatography–electrospray ionization-tandem mass spectrometric (LC–ESI-MS–MS) method was developed for the direct analysis of entacapone glucuronide in plasma. The plasma samples (5 μl) were injected onto a C18-alkyl-diol silica (ADS) column and the matrix compounds were washed to waste with a mixture of 20 mM ammonium acetate solution at pH 4.0–acetonitrile (97:3). The retained analyte fraction containing (E)- and (Z)-isomers of glucuronides of entacapone and tolcapone glucuronide (internal standard) was backflushed to the analytical C18 column, with a mixture of 20 mM ammonium acetate–acetonitrile (85:15) for the final separation at pH 7.0. The eluate was directed to the mass spectrometer after splitting (1:100). The mass spectrometer was operated in the negative ion mode and the deprotonated molecules [M−H] were chosen as precursor ions for the analytes and internal standard. Collisionally induced dissociation of [M−H] in MS–MS resulted in loss of the neutral glucuronide moiety and in the appearance of intensive negatively charged aglycones [M−H−Glu], which were chosen as the product ions for single reaction monitoring. Quantitative studies showed a wide dynamic range (0.0025–100 μg/ml) with correlation coefficients better than 0.995. The method was repeatable within-day (relative standard deviation, RSD<7%) and between-day (RSD<14%) and the recovery (78–103%) was better than with the traditional, laborious pretreatment method. The use of tandem mass spectrometry permitted low limits of detection (1 ng/ml of entacapone glucuronide). The method was applied for the quantitation of (E)- and (Z)-isomers of entacapone glucuronide in plasma of rats used in absorption studies.  相似文献   

19.
A fast, robust and sensitive LC–MS–MS method for the determination of zearalenone (ZON) and its metabolites α-zearalenol (α-ZOL) and β-zearalenol (β-ZOL) in beer samples is described. Sample preparation was performed by direct RP-18 solid-phase extraction of undiluted beer samples followed by selective determination of analytes by LC–MS–MS applying an atmospheric pressure chemical ionization (APCI) interface. Using the negative ion mode limits of determination of 0.03–0.06 μg l−1 beer and limits of quantification of 0.07–0.15 μg l−1 beer were achieved, which was distinctly more sensitive than in the positive ion mode. Twenty-three beer samples from different countries, produced from different grains and under different brewing conditions, were investigated by this method, but only in one sample could β-ZOL and ZON be detected. Independently of the type of beer, relative standard deviations between 2.1% and 3.3%, a linear working range of 0.15 μg l−1 to 500 μg l−1 beer and recovery rates around 100% could be achieved when zearalanone (ZAN) was used as internal standard.  相似文献   

20.
A novel method using high-performance liquid chromatography tandem mass spectrometry (HPLC–MS/MS) has been developed for the quantification of four triterpenoidal saponins (anemoside B4, pulsatilloside B, anemoside A3, and 23-hydroxybetulinic acid) in rat plasma following solid-phase extraction (SPE). The optimized procedure utilized off-line extraction of the analytes from plasma using polymeric (Strata-X) SPE cartridges. Detection and quantitation were performed by MS/MS using electrospray ionization (ESI) and multiple reaction monitoring (MRM) in a novel multiswitching monitoring mode. The analytes and internal standard (scutellarin) were analyzed using a Sapphire C18 column (250 × 4.6 mm, 5 μm) with a linear gradient elution. The mass transition ion pairs of the triterpenoidal saponins were executed as follows: m/z 1219.7/749.4 for anemoside B4, m/z 819.4/347.2 for pulsatilloside B, m/z 749.6/471.2 for anemoside A3, m/z 471.4/471.4 for 23-hydroxybetulinic acid, and m/z 461.1/285.0 for the internal standard. The specificity, linearity, accuracy, precision, recovery, matrix effect, and stabilities were validated for all analytes in the plasma samples. In conclusion, the validation results demonstrate that this method is robust and specific. This validated method is a novel technique for sample preparation and quantitation and was successfully applied to estimate the pharmacokinetics of triterpenoidal saponins.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号