首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
2.
3.
Cramer R  Corless S 《Proteomics》2005,5(2):360-370
We have combined several key sample preparation steps for the use of a liquid matrix system to provide high analytical sensitivity in automated ultraviolet -- matrix-assisted laser desorption/ionisation -- mass spectrometry (UV-MALDI-MS). This new sample preparation protocol employs a matrix-mixture which is based on the glycerol matrix-mixture described by Sze et al. The low-femtomole sensitivity that is achievable with this new preparation protocol enables proteomic analysis of protein digests comparable to solid-state matrix systems. For automated data acquisition and analysis, the MALDI performance of this liquid matrix surpasses the conventional solid-state MALDI matrices. Besides the inherent general advantages of liquid samples for automated sample preparation and data acquisition the use of the presented liquid matrix significantly reduces the extent of unspecific ion signals in peptide mass fingerprints compared to typically used solid matrices, such as 2,5-dihydroxybenzoic acid (DHB) or alpha-cyano-hydroxycinnamic acid (CHCA). In particular, matrix and low-mass ion signals and ion signals resulting from cation adduct formation are dramatically reduced. Consequently, the confidence level of protein identification by peptide mass mapping of in-solution and in-gel digests is generally higher.  相似文献   

4.
Challenges associated with the efficient and effective preparation of micro- and nanoscale (micro- and nanogram) clinical specimens for proteomic applications include the unmitigated sample losses that occur during the processing steps. Herein, we describe a simple "single-tube" preparation protocol appropriate for small proteomic samples using the organic cosolvent, trifluoroethanol (TFE) that circumvents the loss of sample by facilitating both protein extraction and protein denaturation without requiring a separate cleanup step. The performance of the TFE-based method was initially evaluated by comparisons to traditional detergent-based methods on relatively large scale sample processing using human breast cancer cells and mouse brain tissue. The results demonstrated that the TFE-based protocol provided comparable results to the traditional detergent-based protocols for larger, conventionally sized proteomic samples (>100 microg protein content), based on both sample recovery and numbers of peptide/protein identifications. The effectiveness of this protocol for micro- and nanoscale sample processing was then evaluated for the extraction of proteins/peptides and shown effective for small mouse brain tissue samples (approximately 30 microg total protein content) and also for samples of approximately 5000 MCF-7 human breast cancer cells (approximately 500 ng total protein content), where the detergent-based methods were ineffective due to losses during cleanup and transfer steps.  相似文献   

5.
The presence of affinity reagents such as immunoglobulin in preparations for sensitive mass spectrometry analyses can preclude the identification of low-abundance proteins of interest. We report a method whereby antisera are purified and biotinylated prior to use in immunoprecipitation that allows for its efficient removal from proteomic samples via streptavidin capture. This method can similarly be extended to other affinity reagents such as recombinant fusion proteins for enhanced identification of interacting proteins.  相似文献   

6.
Proteomic technologies in modern biomedical science   总被引:8,自引:0,他引:8  
This review highlights modern technologies employed in proteomics. Methods of sample preparations are discussed with special emphasis on the requirements for preparation of biological material, which may seriously influence the results of proteomic studies. Methods of solubilization, electrophoresis, chromatographic protein separation, and visualization of protein spots in gels are described. Modern methods of mass spectrometry used in proteomic studies include combination of protein chips with mass spectrometry. The review also describes approaches of functional proteomics, i.e., interactomics, and also bioinformatic resources used in proteomics for image analysis of 2D-gel-electrophoresis and for identification of protein sequences by mass spectra.  相似文献   

7.
A method was developed in order to analyse high molecular mass proteins by two-dimensional (2-D) electrophoresis using a copolymer of acrylamide and allyl agarose instead of Bis cross-linked polyacrylamide (PA) gels in sodium dodecyl sulphate-electrophoresis. In this work, the matrix composition was optimised to improve the resolution of proteins larger than 200 kDa. The new gel type does not entrap large proteins and protein complexes at the application site. Mechanical properties were investigated through rheological measurements, which suggested the formation of a highly entangled elastomeric soft gel. A high 2-D resolution of proteins, extracted from membranes of red blood cells, was obtained in these gels. An example of tryptic digestion, peptide extraction and matrix-assisted laser desorption/ionisation-time of flight mass spectrometry was reported. The results demonstrate that the new gel is fully compatible with mass spectrometry protein analysis.  相似文献   

8.
Confinement of proteins and peptides in a small inert space mimics the natural environment of the cell, allowing structural studies in conditions that stabilize folded conformations. We have previously shown that confinement in polyacrylamide gels (PAGs) is sufficient to induce a change in the viscosity of the aqueous solution without changing the composition and temperature of the solvent. The main limitation of a PAG to run NMR experiments in a confined environment is the need for labelling the peptides. Here we report the use of the agarose gel to run the NMR spectra of proteins and peptides. We show that agarose gels are completely transparent in NMR experiments, relieving the need for labelling. Although it is necessary to expose biomolecules to fairly high temperatures during sample preparation, we believe that this is not generally an obstacle to the study of peptides, and found that the method is also compatible with temperature-resistant proteins. The mesh of agarose gels is too wide for direct effects of confinement on the stability of proteins but confinement can be easily exploited to interact the proteins with other reagents, including crowding macromolecules that can eventually lead to fold stabilization. The use of these gels is ideally suited for low-temperature studies; we show that a very flexible peptide at subzero temperatures is stabilized into a well-folded conformation.  相似文献   

9.
Reversed phase high performance liquid chromatography (HPLC) interfaced to electrospray tandem mass spectrometry (MS/MS) is commonly used for the identification of peptides from proteolytically cleaved proteins embedded in a polyacrylamide gel matrix as well as for metabolomics screening. HPLC separations are time consuming (30-60 min average), costly (columns and mobile phase reagents), and carry the risk of column carry over between samples. The use of a chip-based nano-ESI platform (Advion NanoMate) based on replaceable nano-tips for sample introduction eliminates sample cross-contamination, provides unchanging sample matrix, and enhances spray stability with attendant increases in reproducibility. Recent papers have established direct infusion nano-ESI-MS/MS utilizing the NanoMate for protein identification of gel spots based on full range MS scans with data dependent MS/MS. In a full range scan, discontinuous ion suppression due to sample matrix can impair identification of putative mass features of interest in both the proteomic and metabolomic workflows. In the current study, an extension of an established direct inject nano-ESI-MS/MS method is described that utilizes the mass filtering capability of an ion-trap for ion packet separation into four narrow mass ranges (50 amu overlap) with segment specific dynamic data dependent peak inclusion for MS/MS fragmentation (total acquisition time of 3 minutes). Comparison of this method with a more traditional nanoLC-MS/MS based protocol utilizing solvent/sample stream splitting to achieve nanoflow demonstrated comparable results for protein identification from polyacrylamide gel matrices. The advantages of this method include full automation, lack of cross-contamination, low cost, and high throughput.  相似文献   

10.
The Entamoeba histolytica genome project carried out at TIGR and the Sanger Institute has produced a near-complete set of deduced open reading frame sequences. These data provide strong support for the identification of signals from proteomic analyses such as two-dimensional electrophoresis by protein sequencing and/or mass spectrometric methods. To carry out an initial investigation of the E. histolytica proteome, appropriate sample preparation and silver staining protocols were adapted. After preparation of protein extracts from E. histolytica HM-1:IMSS trophozoites, solubilized proteins were separated in the first dimension in IPG (immobilized pH gradient) strips depending on their pI and subsequently in the second dimension according to their molecular weight by SDS-polyacrylamide gel electrophoresis. Of the more than 1500 protein spots visualized, several landmark spots were isolated from the gels and identified by either tryptic cleavage and subsequent MALDI-TOF mass spectrometry or by protein sequencing.  相似文献   

11.
Matrix-assisted laser desorption with concomitant ionization, in combination with a linear time-of-flight mass spectrometer, was used to analyze underivatized and hard-to-solubilize surface layer proteins and glycoproteins by depositing them on top of a microcrystalline layer of the matrix alpha-cyano-4-hydroxycinnamic acid. Use of this special sample preparation technique allowed the first successful desorption-ionization of intact surface layer proteins and accurate determination of their molecular weights by mass spectrometry. The molecular mass of the monomeric subunit of the major surface layer protein isolated from Clostridium thermosaccharolyticum E207-71 was determined to be 75,621 +/- 81 Da. The obtainable mass accuracy of the technique is conservatively considered to be within +/- 0.2%. This result deviates from that given by sodium dodecyl sulfate-polyacrylamide gel electrophoresis by approximately 7.4 kDa because this method is strongly affected and biased by the three-dimensional structure of this type of surface protein. With the apparent advantages of unsurpassed mass accuracy, low dependence on the physicochemical properties of the surface layer proteins, and high sensitivity, it can be concluded that a linear time-of-flight instrument combined with UV matrix-assisted laser desorption with concomitant ionization is better suited for molecular weight determination than is gel electrophoresis.  相似文献   

12.
Blood serum is a complex body fluid that contains various proteins ranging in concentration over at least 9 orders of magnitude. Using a combination of mass spectrometry technologies with improvements in sample preparation, we have performed a proteomic analysis with submilliliter quantities of serum and increased the measurable concentration range for proteins in blood serum beyond previous reports. We have detected 490 proteins in serum by on-line reversed-phase microcapillary liquid chromatography coupled with ion trap mass spectrometry. To perform this analysis, immunoglobulins were removed from serum using protein A/G, and the remaining proteins were digested with trypsin. Resulting peptides were separated by strong cation exchange chromatography into distinct fractions prior to analysis. This separation resulted in a 3-5-fold increase in the number of proteins detected in an individual serum sample. With this increase in the number of proteins identified we have detected some lower abundance serum proteins (ng/ml range) including human growth hormone, interleukin-12, and prostate-specific antigen. We also used SEQUEST to compare different protein databases with and without filtering. This comparison is plotted to allow for a quick visual assessment of different databases as a subjective measure of analytical quality. With this study, we have performed the most extensive analysis of serum proteins to date and laid the foundation for future refinements in the identification of novel protein biomarkers of disease.  相似文献   

13.
TRIzol is used for RNA isolation but also permits protein recovery. We investigated whether proteins prepared with TRIzol were suitable for two-dimensional gel electrophoresis (2-DE) and matrix-assisted laser desorption/ionization mass spectrometry. Proteins from TRIzol-treated SH-SY5Y cells produced 2-DE spot patterns similar to those from an equivalent untreated sample. Subsequent identification of TRIzol-treated proteins using peptide mass fingerprinting was successful. TRIzol exposure altered neither the mass of myoglobin extracted from sodium dodecyl sulfate (SDS) gels nor the masses of myoglobin peptides produced by in-gel trypsin digestion. These findings suggest that proteins isolated with TRIzol remain amenable to proteomic analyses.  相似文献   

14.
Xiong S  Ding Q  Zhao Z  Chen W  Wang G  Liu S 《Proteomics》2003,3(3):265-272
High detection sensitivity and resolution are two critical parameters for recording good peptide mass fingerprints (PMF) of low abundance proteins. This paper reports a mass spectrometry (MS) sample preparation technique that could improve sensitivity and resolution. By coating the MS steel target with a thin layer of pentadecafluorooctamido propyltrimethoxysilane, which was both polar and nonpolar solvent repellent, the transferred sample droplets on its surface were significantly smaller. As a result, the analyte of the peptide mixture became more concentrated and homogeneous, which helped to improve the sensitivity. The advantages of a modified MS target were documented by mass spectra improvement of attomole level standard peptides and silver-stained proteins from polyacrylamide gels. The mass signal of angiotensin II at 100 attomole was difficult to record on the conventional support, whereas it was easily detected on the modified one. The PMF of cytochrome C was also better recorded on the modified support, in terms of both signal-to-noise ratio and the number of detected peptides. When silver-stained proteins from two-dimensional electrophoresis gels were analyzed, in most cases more satisfactory peptide mass spectra were obtained from the modified support. Searching protein databases with more mass data from the improved PMFs, several unknown proteins were successfully identified.  相似文献   

15.
A procedure is described for the preparation of 1.32-10% polyacrylamide gradient gels. Loose polyacrylamide gel on the top side of the gradient was stabilized with a layer of 0.4% agarose gel which also formed sample wells. The upper limit of separation achieved in these gels was estimated to be approximately 2 X 10(6) using globular protein standards. However, large aggregating proteoglycans from cartilage which have a molecular weight range of 1-4 X 10(6) penetrate and separate in these gels. A simple one-step procedure is also described for simultaneous staining of proteins and large proteoglycans in polyacrylamide gels.  相似文献   

16.
Archived formalin-fixed paraffin-embedded (FFPE) tissue collections represent a valuable informational resource for proteomic studies. Multiple FFPE core biopsies can be assembled in a single block to form tissue microarrays (TMAs). We describe a protocol for analyzing protein in FFPE-TMAs using matrix-assisted laser desorption/ionization (MALDI) imaging mass spectrometry (IMS). The workflow incorporates an antigen retrieval step following deparaffinization, in situ trypsin digestion, matrix application and then mass spectrometry signal acquisition. The direct analysis of FFPE-TMA tissue using IMS allows direct analysis of multiple tissue samples in a single experiment without extraction and purification of proteins. The advantages of high speed and throughput, easy sample handling and excellent reproducibility make this technology a favorable approach for the proteomic analysis of clinical research cohorts with large sample numbers. For example, TMA analysis of 300 FFPE cores would typically require 6 h of total time through data acquisition, not including data analysis.  相似文献   

17.
Here we describe an original strategy for unbiased quantification of protein expression called difference in mass analysis using labeled lysine (K) (DIMAL-K). DIMAL-K is based on the differential predigestion labeling of lysine residues in complex protein mixtures. The method is relevant for proteomic analysis by two-dimensional electrophoresis and MALDI-TOF mass spectrometry. Protein labeling on lysine residues uses two closely related chemical reagents, S-methyl thioacetimidate and S-methyl thiopropionimidate. Using protein standards, we demonstrated that 1) the chemical labeling was quantitative, specific, and rapid; 2) the differentially labeled proteins co-migrated on two-dimensional gels; and 3) the identification by mass fingerprinting and the relative quantification of the proteins were possible from a single MALDI-TOF mass spectrum. The power of the method was tested by comparing and quantifying the secretion of proteins in normal and proinflammatory astrocytic secretomes (20 microg). We showed that DIMAL-K was more sensitive and accurate than densitometric image analysis and allowed the detection and quantification of novel proteins.  相似文献   

18.
Establishment of a near-standard two-dimensional human urine proteomic map   总被引:9,自引:0,他引:9  
Oh J  Pyo JH  Jo EH  Hwang SI  Kang SC  Jung JH  Park EK  Kim SY  Choi JY  Lim J 《Proteomics》2004,4(11):3485-3497
A proteomic map for human urine on two-dimensional (2-D) gels has been developed. Initial studies demonstrated that the urine proteins prepared by conventional methods showed interference and poor reproducibility in 2-D electrophoresis (2-DE). To address this issue, urine samples were dialyzed to remove any interfering molecules. The dialysis of urine proteins and the concentration by lyophilization without fractionation significantly improved the reproducibility and resolution and likely represents the total urine proteins on a 2-D gel. In addition, removing albumin from urine using Affi-Gel Blue helped to identify the low-abundant proteins. Using the developed method, we prepared proteins from urine collected from healthy females and males. The large inter- and intra-subject variation in protein profiles on 2-D gels made it difficult to establish a normal human urine proteomic 2-D map. To resolve this problem, urinary proteins were prepared from the pooled urine collected from 20 healthy females and males, respectively. The established male and female urine proteomes separated on 2-D gels were almost identical except for some potential sex-dependent protein spots. We have annotated 113 different proteins on the 2-D gel by peptide mass fingerprinting (PMF). We propose that the established total urine proteome can be used for 2-DE analysis, liquid chromatography-tandem mass spectrometry (LC-MS/MS), and identification of novel disease-specific biomarkers.  相似文献   

19.
An important step in the proteomic analysis of missing proteins is the use of a wide range of tissues, optimal extraction, and the processing of protein material in order to ensure the highest sensitivity in downstream protein detection. This work describes a purification protocol for identifying low-abundance proteins in human chorionic villi using the proposed “1DE-gel concentration” method. This involves the removal of SDS in a short electrophoresis run in a stacking gel without protein separation. Following the in-gel digestion of the obtained holistic single protein band, we used the peptide mixture for further LC–MS/MS analysis. Statistically significant results were derived from six datasets, containing three treatments, each from two tissue sources (elective or missed abortions). The 1DE-gel concentration increased the coverage of the chorionic villus proteome. Our approach allowed the identification of 15 low-abundance proteins, of which some had not been previously detected via the mass spectrometry of trophoblasts. In the post hoc data analysis, we found a dubious or uncertain protein (PSG7) encoded on human chromosome 19 according to neXtProt. A proteomic sample preparation workflow with the 1DE-gel concentration can be used as a prospective tool for uncovering the low-abundance part of the human proteome.  相似文献   

20.
Attempts at protein profiling in the alkaline pH region using isoelectric focusing have often proved difficult, greatly limiting the scope of proteome analysis. We investigated several parameters using custom pH 8-11 immobilized pH gradients to separate a Caulobacter crescentus membrane preparation. These included sample application, quenching endoosomotic flow and gel matrix composition. Among these factors, the sample application position was the predominant parameter to affect two-dimensional gel quality. Separated proteins were silver stained and profiled using matrix-assisted laser desorption/ionization (MALDI) mass spectrometry. The use of a prototype MALDI-Q-Tof mass spectrometer assisted identification of several proteins by providing highly informative peptide fragmentation data from the sample digests. Thirty-two unique alkaline proteins were identified in this study, which complements our previously described C. crescentus membrane proteome. Our experiments point towards new options for proteomic researchers aiming to both extend the scope of analysis, and simplify methods of identifying proteins with high confidence.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号