首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A new real-time PCR assay was developed and validated in combination with an immunomagnetic separation system for the quantitative determination of Legionella pneumophila in water samples. Primers that amplify simultaneously an 80-bp fragment of the dotA gene from L. pneumophila and a recombinant fragment including a specific sequence of the gyrB gene from Aeromonas hydrophila, added as an internal positive control, were used. The specificity, limit of detection, limit of quantification, repetitivity, reproducibility, and accuracy of the method were calculated, and the values obtained confirmed the applicability of the method for the quantitative detection of L. pneumophila. Moreover, the efficiency of immunomagnetic separation in the recovery of L. pneumophila from different kinds of water was evaluated. The recovery rates decreased as the water contamination increased (ranging from 59.9% for distilled water to 36% for cooling tower water), and the reproducibility also decreased in parallel to water complexity. The feasibility of the method was evaluated by cell culture and real-time PCR analysis of 60 samples in parallel. All the samples found to be positive by cell culture were also positive by real-time PCR, while only eight samples were found to be positive only by PCR. Finally, the correlation of both methods showed that the number of cells calculated by PCR was 20-fold higher than the culture values. In conclusion, the real-time PCR method combined with immunomagnetic separation provides a sensitive, specific, and accurate method for the rapid quantification of L. pneumophila in water samples. However, the recovery efficiency of immunomagnetic separation should be considered in complex samples.  相似文献   

2.
We evaluated a ready-to-use real-time quantitative Legionella pneumophila PCR assay system by testing 136 hot-water-system samples collected from 55 sites as well as 49 cooling tower samples collected from 20 different sites, in parallel with the standard culture method. The PCR assay was reproducible and suitable for routine quantification of L. pneumophila. An acceptable correlation between PCR and culture results was obtained for sanitary hot-water samples but not for cooling tower samples. We also monitored the same L. pneumophila-contaminated cooling tower for 13 months by analyzing 104 serial samples. The culture and PCR results were extremely variable over time, but the curves were similar. The differences between the PCR and culture results did not change over time and were not affected by regular biocide treatment. This ready-to-use PCR assay for L. pneumophila quantification could permit more timely disinfection of cooling towers.  相似文献   

3.
Contamination of hospital water systems with legionellae is a well-known cause of nosocomial legionellosis. We describe a new real-time LightCycler PCR assay for quantitative determination of legionellae in potable water samples. Primers that amplify both a 386-bp fragment of the 16S rRNA gene from Legionella spp. and a specifically cloned fragment of the phage lambda, added to each sample as an internal inhibitor control, were used. The amplified products were detected by use of a dual-color hybridization probe assay design and quantified with external standards composed of Legionella pneumophila genomic DNA. The PCR assay had a sensitivity of 1 fg of Legionella DNA (i.e., less than one Legionella organism) per assay and detected 44 Legionella species and serogroups. Seventy-seven water samples from three hospitals were investigated by PCR and culture. The rates of detection of legionellae were 98.7% (76 of 77) by the PCR assay and 70.1% (54 of 77) by culture; PCR inhibitors were detected in one sample. The amounts of legionellae calculated from the PCR results were associated with the CFU detected by culture (r = 0.57; P < 0.001), but PCR results were mostly higher than the culture results. Since L. pneumophila is the main cause of legionellosis, we further developed a quantitative L. pneumophila-specific PCR assay targeting the macrophage infectivity potentiator (mip) gene, which codes for an immunophilin of the FK506 binding protein family. All but one of the 16S rRNA gene PCR-positive water samples were also positive in the mip gene PCR, and the results of the two PCR assays were correlated. In conclusion, the newly developed Legionella genus-specific and L. pneumophila species-specific PCR assays proved to be valuable tools for investigation of Legionella contamination in potable water systems.  相似文献   

4.
Aims: This study was designed to evaluate the usefulness of quantification by real‐time PCR as a management tool to monitor concentrations of Legionella spp. and Legionella pneumophila in industrial cooling systems and its ability to anticipate culture trends by the French standard method (AFNOR T90‐431). Methods and Results: Quantifications of Legionella bacteria were achieved by both methods on samples from nine cooling systems with different water qualities. Proportion of positive samples for L. pneumophila quantified by PCR was clearly lower in deionized or river waters submitted to a biocide treatment than in raw river waters, while positive samples for Legionella spp. were quantified for almost all the samples. For some samples containing PCR inhibitors, high quantification limits (up to 4·80 × 105 GU l?1) did not allow us to quantify L. pneumophila, when they were quantified by culture. Finally, the monitoring of concentrations of L. pneumophila by both methods showed similar trends for 57–100% of the samples. Conclusions: These results suggest that, if some methodological steps designed to reduce inhibitory problems and thus decrease the quantification limits, could be developed to quantify Legionella in complex waters, the real‐time PCR could be a valuable complementary tool to monitor the evolution of L. pneumophila concentrations. Significance and Impact of the Study: This study shows the possibility of using real‐time PCR to monitor L. pneumophila proliferations in cooling systems and the importance to adapt nucleic acid extraction and purification protocols to raw waters.  相似文献   

5.
A sensitive and specific method has been developed to enumerate viable L. pneumophila and other Legionella spp. in water by epifluorescence microscopy in a short period of time (a few hours). This method allows the quantification of L. pneumophila or other Legionella spp. as well as the discrimination between viable and nonviable Legionella. It simultaneously combines the specific detection of Legionella cells using antibodies and a bacterial viability marker (ChemChrome V6), the enumeration being achieved by epifluorescence microscopy. The performance of this immunological double-staining (IDS) method was investigated in 38 natural filterable water samples from different aquatic sources, and the viable Legionella counts were compared with those obtained by the standard culture method. The recovery rate of the IDS method is similar to, or higher than, that of the conventional culture method. Under our experimental conditions, the limit of detection of the IDS method was <176 Legionella cells per liter. The examination of several samples in duplicates for the presence of L. pneumophila and other Legionella spp. indicated that the IDS method exhibits an excellent intralaboratory reproducibility, better than that of the standard culture method. This immunological approach allows rapid measurements in emergency situations, such as monitoring the efficacy of disinfection shock treatments. Although its field of application is as yet limited to filterable waters, the double-staining method may be an interesting alternative (not equivalent) to the conventional standard culture methods for enumerating viable Legionella when rapid detection is required.  相似文献   

6.
Rapid and more sensitive methods for the detection and quantification of viable Legionella cells have been developed. In this paper, a comparative analysis of environmental water samples using the ScanVIT-Legionella? method and the traditional “gold standard” method of culturing is realised indicating the usefulness of the ScanVIT method. The ScanVIT-Legionella? method was performed on environmental water samples from different locations of Huesca region (Spain). Legionella micro-colonies should appear green colour and Legionella pneumophila micro-colonies appear red. Twenty-one environmental water samples analysed by standard culture plus five control samples (Two sterile water samples with Legionella as positive controls and three sterile water samples as negative controls). All of them were used to apply ScanVIT-Legionella? method. From of 21 environmental samples eleven were positive, six negative with both methods and four samples were negative for culture method and positive for ScanVIT-Legionella? method. The positive control samples were positive and the negative were negative for both methods. A comparative analysis of the results obtained with two methods showed a strong positive determination coefficient (R2 = 0.99753). The results demonstrate the usefulness of the ScanVIT-Legionella? method as a rapid diagnostic tool in order to provide a diagnosis as quick as possible. ScanVIT-Legionella? method offers a series of advantages such as quickly diagnosis, higher sensitivity and the possibility to identify Legionella spp. and L. pneumophila simultaneously.  相似文献   

7.
Legionella pneumophila is accounted for more than 80% of Legionella infection. However it is difficult to discriminate between the L. pneumophila and non-L. pneumophila species rapidly. In order to detect the Legionella spp. and distinguish L. pneumophila from Legionella spp., a real-time loop-mediated isothermal amplification (LAMP) platform that targets a specific sequence of the 16S rRNA gene was developed. LS-LAMP amplifies the fragment of the 16S rRNA gene to detect all species of Legionella genus. A specific sequence appears at the 16S rRNA gene of L. pneumophila, while non-L. pneumophila strains have a variable sequence in this site, which can be recognized by the primer of LP-LAMP. In the present study, 61 reference strains were used for the method verification. We found that the specificity was 100% for both LS-LAMP and LP-LAMP, and the sensitivity of LAMP assay for L. pneumophila detection was between 52 and 5.2 copies per reaction. In the environmental water samples detection, a total of 107 water samples were identified by the method. The culture and serological test were used as reference methods. The specificity of LS-LAMP and LP-LAMP for the samples detection were 91.59% (98/107) and 93.33% (56/60), respectively. The sensitivity of LS-LAMP and LP-LAMP were 100% (51/51) and 100% (18/18). The results suggest that real-time LAMP, as a new assay, provides a specific and sensitive method for rapid detection and differentiation of Legionella spp. and L. pneumophila and should be utilized to test environmental water samples for increased rates of detection.  相似文献   

8.
Aims: Legionella isolation from environmental samples is often difficult because of the presence of heterotrophic‐associated bacteria that frequently overgrow when using standard culture (ISO 11731, 1998; NF T90‐431, 2003) methods. To improve Legionella pneumophila recovery from complex water samples (water from cooling towers, biofilms), we evaluated an immunomagnetic separation (IMS) assay using a monoclonal antibody raised against the lipopolysaccharide of Leg. pneumophila sg1 in combination with culture. Methods and Results: This study was conducted on 51 environmental specimens. The comparison between IMS‐culture and standard culture (ISO 11731, 1998; NF T90‐431, 2003) methods was made using ISO 17994, 2004 criteria for establishing equivalence between microbiological methods based on the upper and lower (XH and XL) values of the relative difference (95% confidence limit) and D as maximum acceptable deviation (value of the confidence limit). Conclusions: We found that the average performance of IMS culture was higher than the reference method. Significance and Impact of the Study: Thus, this IMS‐culture assay is particularly well adapted to the detection of Leg. pneumophila sg1 in environmental samples with high levels of interfering microflora.  相似文献   

9.
Necrotrophic Growth of Legionella pneumophila   总被引:1,自引:0,他引:1       下载免费PDF全文
This study examined whether Legionella pneumophila is able to thrive on heat-killed microbial cells (necrotrophy) present in biofilms or heat-treated water systems. Quantification by means of plate counting, real-time PCR, and flow cytometry demonstrated necrotrophic growth of L. pneumophila in water after 96 h, when at least 100 dead cells are available to one L. pneumophila cell. Compared to the starting concentration of L. pneumophila, the maximum observed necrotrophic growth was 1.89 log units for real-time PCR and 1.49 log units for plate counting. The average growth was 1.57 ± 0.32 log units (n = 5) for real-time PCR and 1.14 ± 0.35 log units (n = 5) for plate counting. Viability staining and flow cytometry showed that the fraction of living cells in the L. pneumophila population rose from the initial 54% to 82% after 96 h. Growth was measured on heat-killed Pseudomonas putida, Escherichia coli, Acanthamoeba castellanii, Saccharomyces boulardii, and a biofilm sample. Gram-positive organisms did not result in significant growth of L. pneumophila, probably due to their robust cell wall structure. Although necrotrophy showed lower growth yields compared to replication within protozoan hosts, these findings indicate that it may be of major importance in the environmental persistence of L. pneumophila. Techniques aimed at the elimination of protozoa or biofilm from water systems will not necessarily result in a subsequent removal of L. pneumophila unless the formation of dead microbial cells is minimized.  相似文献   

10.
A new method for the rapid and sensitive detection of Legionella pneumophila in hot water systems has been developed. The method is based on an IF assay combined with detection by solid-phase cytometry. This method allowed the enumeration of L. pneumophila serogroup 1 and L. pneumophila serogroups 2 to 6, 8 to 10, and 12 to 15 in tap water samples within 3 to 4 h. The sensitivity of the method was between 10 and 100 bacteria per liter and was principally limited by the filtration capacity of membranes. The specificity of the antibody was evaluated against 15 non-Legionella strains, and no cross-reactivity was observed. When the method was applied to natural waters, direct counts of L. pneumophila were compared with the number of CFU obtained by the standard culture method. Direct counts were always higher than culturable counts, and the ratio between the two methods ranged from 1.4 to 325. Solid-phase cytometry offers a fast and sensitive alternative to the culture method for L. pneumophila screening in hot water systems.  相似文献   

11.
Cryptosporidium parvum and C. hominis have been the cause of large and serious outbreaks of waterborne cryptosporidiosis. A specific and sensitive recovery-detection method is required for control of this pathogen in drinking water. In the present study, nested PCR-restriction fragment length polymorphism (RFLP), which targets the divergent Cpgp40/15 gene, was developed. This nested PCR detected only the gene derived from C. parvum and C. hominis strains, and RFLP was able to discriminate between the PCR products from C. parvum and C. hominis. To evaluate the sensitivity of nested PCR, C. parvum oocysts inoculated in water samples of two different turbidities were recovered by immunomagnetic separation (IMS) and detected by nested PCR and fluorescent antibody assay (FA). Genetic detection by nested PCR and oocyst number confirmed by FA were compared, and the results suggested that detection by nested PCR depends on the confirmed oocyst number and that nested PCR in combination with IMS has the ability to detect a single oocyst in a water sample. We applied an agitation procedure with river water solids to which oocysts were added to evaluate the recovery and detection by the procedure in environmental samples and found some decrease in the rate of detection by IMS.  相似文献   

12.
In this study, we examined the potential for detecting fecal bacteria and microbial source tracking markers in samples discarded during the concentration of Cryptosporidium and Giardia using USEPA Method 1623. Recovery rates for different fecal bacteria were determined in sewage spiked samples and environmental waters using different group-specific and host-specific PCR assays. Bacteroidales DNA recovery ranged from 59 to 71% for aliquots of supernatant collected after the elution step. The recovery of human-specific Bacteroidales DNA from sewage spiked samples was 54% in the elution step. An additional 1-7% Bacteroidales DNA was recovered after the immunomagnetic separation step, while recovery from the pellet left after the immunomagnetic separation of protozoa parasites was substantially lower. Comparison of Bacteroidales 16S rRNA gene sequences from elution and immunomagnetic separation discarded samples indicated that the distribution of clones was not statistically different, suggesting that there were no recovery biases introduced by these steps. Human- and cow-specific Bacteroidales and fecal indicator bacteria (i.e., enterococci,) were also detected in the discarded fractions of environmental samples collected from different geographic locations. Overall, the results of this study demonstrated the potential application of leftover sample fractions that are currently discarded for the PCR detection of fecal bacterial indicators and molecular source tracking.  相似文献   

13.
A total of 25 gyrB gene sequences from 20 Legionella pneumophila subsp. pneumophila strains and five L. pneumophila subsp. fraseri strains were obtained and analyzed, and a multiplex PCR for the simultaneous detection of Legionella bozemanae, Legionella longbeachae, Legionella micdadei and Legioenella pneumophila, and two single PCRs for the differentiation of L. pneumophila subsp. pneumophila and L. pneumophila subsp. fraseri were established. The multiplex PCR method was shown to be highly specific and reproducible when tested against 41 target strains and 17 strains of other bacteria species. The sensitivity of the multiplex PCR was also analyzed and was shown to detect levels as low as 1 ng of genomic DNA or 10 colony-forming units (CFUs) per milliliter in mock water samples. Sixty-three air conditioner condensed water samples from Shanghai City were examined, and the result was validated using 16S rRNA sequencing. The data reported here demonstrate that the multiplex PCR method described is efficient and convenient for the detection of Legionella species in water samples. Twenty L. pneumophila subsp. pneumophila strains and five L. pneumophila subsp. fraseri strains were used for the validation of the two L. pneumophila subspecies-specific PCR methods, and the results indicated that the two PCR methods were both highly specific and convenient for the identification of L. pneumophila at the subspecies level.  相似文献   

14.
The objective was to obtain research-based, holistic knowledge about necessity and effect of practiced measures against L. pneumophila in municipal shower systems in Stavanger, Norway. The effects of hot water treatment and membrane-filtering were investigated and compared to no intervention at all. The studies were done under real-world conditions. Additionally, a surveillance pilot study of municipal showers in Stavanger was performed. The validity of high total plate count (TPC) as an indication of L. pneumophila was evaluated. A simplified method, named “dripping method”, for detection and quantification of L. pneumophila was developed. The sensitivity of the dripping method is 5 colony-forming units of L. pneumophila/ml. The transference of L. pneumophila from shower water to aerosols was studied. Interviews and observational studies among the stakeholders were done in order to identify patterns of communication and behavior in a Legionella risk perspective. No substantial effects of the measures against L. pneumophila were demonstrated, except for a distally placed membrane filter. No significant positive correlation between TPC and L. pneumophila concentrations were found. L. pneumophila serogroup 2–14 was demonstrated in 21% of the 29 buildings tested in the surveillance pilot. Relatively few cells of L. pneumophila were transferred from shower water to aerosols. Anxiety appeared as the major driving force in the risk governance of Legionella. In conclusion, the risk of acquiring Legionnaires'' disease from municipal shower systems is evaluated as low and uncertain. By eliminating ineffective approaches, targeted Legionella risk governance can be practiced. Risk management by surveillance is evaluated as appropriate.  相似文献   

15.
Microsporidia are obligate intracellular pathogens capable of infecting humans. There is credible evidence to suggest that microsporidial infections may be transmitted through consumption of spores in contaminated water; however, methods to detect this pathogen have not been standardized and microsporidia occurrence studies have not been conducted. Concentration of spores by continuous flow centrifugation (CFC), purification using immunomagnetic separation (IMS), and detection by either microscopy or real-time polymerase chain reaction (PCR) were evaluated for detection of Encephalitozoon intestinalis spores in seeded water samples. Recovery efficiency of CFC using microscopic detection ranged from 38.7-75.5% in filtered tap water. Using an indirect IMS method, 78.8-90.2% of seeded spores were recovered in ultrapure water (18 M Omega); however, the lack of a specific monoclonal antibody and the presence of other particulates interfered with the IMS assay in some turbid samples. Despite low recovery efficiencies and the detectable presence of PCR inhibitors in each of the samples, a combination of CFC concentration, indirect IMS, and real-time PCR produced a positive test result in six of ten natural water samples (turbidity 0.1-28.9 NTU) at a seeding level of 50 spores/L.  相似文献   

16.
Aims:  A new real-time PCR assay that simultaneously amplifies a 102-bp fragment of the cagE gene from Helicobacter pylori and a new internal positive control containing a specific sequence of the gyrB gene from Aeromonas hydrophila , was developed and validated for the detection of H. pylori in environmental samples.
Methods and Results:  The specificity, limits of detection and quantification, repeatability, reproducibility, and accuracy of the method were calculated. The resulting values confirmed the applicability of the method for the quantitative detection of H. pylori . The feasibility of the method was also evaluated by testing 13 pyloric antrum-positive biopsies and 69 water samples, including potable (10), surface (19) and wastewater (40) matrices. The results showed that all the biopsies and 3 of the 40 wastewater samples analysed were positive.
Conclusions:  This real-time PCR method provides a sensitive, specific, and accurate method for the rapid quantification of H. pylori in environmental samples.
Significance and Impact of the Study:  The PCR diagnostic system proposed in this work, provides a suitable tool for the quantitative detection of H. pylori in environmental samples and can be useful for verifying the role of water as a potential route of its transmission.  相似文献   

17.
Aims: To compare the standard culture method with a new, rapid test (ScanVIT‐Legionella?) using fluorescently labelled gene probes for the detection and enumeration of Legionella spp. The new technique was validated through experiments conducted on both artificially and naturally contaminated water and through an inter‐laboratory comparison. Methods and Results: All samples were processed by the ScanVIT test according to the manufacturer’s instructions and by a culture method (ISO 11731). ScanVIT detected significantly more positive samples, although concentrations were similar and a strong positive correlation between the two methods was observed (r = 0·888, P < 0·001). The new test was more accurate in identifying the co‐presence of Legionella pneumophila and Leg. non‐pneumophila. ScanVIT showed a slightly higher Legionella recovery from water samples artificially contaminated with Leg. pneumophila alone or together with Pseudomonas aeruginosa. Lastly, the inter‐laboratory comparison revealed that the ScanVIT test exhibits a lower variability than the traditional culture test (mean coefficient of variation 8·7 vs 16·1%). Conclusions: The results confirmed that the ScanVIT largely overlaps the reference method and offers advantages in terms of sensitivity, quantitative reliability and reduced assay time. Significance and Impact of the Study: The proposed method may represent a useful validated alternative to traditional culture for the rapid detection and quantification of Legionella spp. in water.  相似文献   

18.
A real-time PCR-based method targeting the 18S rRNA gene was developed for the quantitative detection of Hartmannella vermiformis, a free-living amoeba which is a potential host for Legionella pneumophila in warm water systems and cooling towers. The detection specificity was validated using genomic DNA of the closely related amoeba Hartmannella abertawensis as a negative control and sequence analysis of amplified products from environmental samples. Real-time PCR detection of serially diluted DNA extracted from H. vermiformis was linear for microscopic cell counts between 1.14 × 10−1 and 1.14 × 104 cells per PCR. The genome of H. vermiformis harbors multiple copies of the 18S rRNA gene, and an average number (with standard error) of 1,330 ± 127 copies per cell was derived from real-time PCR calibration curves for cell suspensions and plasmid DNA. No significant differences were observed between the 18S rRNA gene copy numbers for trophozoites and cysts of strain ATCC 50237 or between the copy numbers for this strain and strain KWR-1. The developed method was applied to water samples (200 ml) collected from a variety of lakes and rivers serving as sources for drinking water production in The Netherlands. Detectable populations were found in 21 of the 28 samples, with concentrations ranging from 5 to 75 cells/liter. A high degree of similarity (≥98%) was observed between sequences of clones originating from the different surface waters and between these clones and the reference strains. Hence, H. vermiformis, which is highly similar to strains serving as hosts for L. pneumophila, is a common component of the microbial community in fresh surface water.  相似文献   

19.
A PMA (propidium monoazide) pretreatment protocol, in which PMA is applied directly to membrane filters, was developed for the PCR-based quantification (PMA-qPCR) of viable Legionella pneumophila. Using this method, the amplification of DNA from membrane-damaged L. pneumophila was strongly inhibited for samples containing a small number of dead bacteria.  相似文献   

20.
Culture-based methods to detect the six major non-O157 (O26, O45, O103, O111, O121 and O145) Shiga toxin-producing E. coli (STEC) are not well established. Our objectives of this study were to develop a culture-based method to detect the six non-O157 serogroups in cattle feces and compare the detection with a PCR method. Fecal samples (n = 576) were collected in a feedlot from 24 pens during a 12-week period and enriched in E. coli broth at 40° C for 6 h. Enriched samples were subjected to immunomagnetic separation, spread-plated onto a selective chromogenic medium, and initially pooled colonies, and subsequently, single colonies were tested by a multiplex PCR targeting six serogroups and four virulence genes, stx1, stx2, eae, and ehxA (culture method). Fecal suspensions, before and after enrichment, were also tested by a multiplex PCR targeting six serogroups and four virulence genes (PCR method). There was no difference in the proportions of fecal samples that tested positive (74.3 vs. 77.4%) for one or more of the six serogroups by either culture or the PCR method. However, each method detected one or more of the six serogroups in samples that were negative by the other method. Both culture method and PCR indicated that O26, O45, and O103 were the dominant serogroups. Higher proportions (P < 0.05) of fecal samples were positive for O26 (44.4 vs. 22.7%) and O121 (22.9 vs. 2.3%) serogroups by PCR than by the culture method. None of the fecal samples contained more than four serogroups. Only a small proportion of the six serogroups (23/640; 3.6%) isolated carried Shiga toxin genes. The culture method and the PCR method detected all six serogroups in samples negative by the other method, highlighting the importance of subjecting fecal samples to both methods for accurate detection of the six non-O157 STEC in cattle feces.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号