首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
2.
This study reports the development of an on-chip enzyme-mediated primer extension process based on a microfluidic device with microbeads array for single-nucleotide discrimination using quantum dots as labels. The functionalized microbeads were independently introduced into the arrayed chambers using the loading chip slab. A single channel was used to generate weir structures to confine the microbeads and make the beads array accessible by microfluidics. The applied allele-specific primer extension method employed a nucleotide-degrading enzyme (apyrase) to achieve specific single-nucleotide detection. Based on the apyrase-mediated allele-specific primer extension with quantum dots as labels, on-chip single-nucleotide discrimination was demonstrated with high discrimination specificity and sensitivity (0.5 pM, signal/noise > 3) using synthesized target DNA. The chip-based signal enhancement for single-nucleotide discrimination resulted in 200 times higher sensitivity than that of an off-chip test. This microfluidic device successfully achieved simultaneous detection of two disease-associated single-nucleotide polymorphism sites using polymerase chain reaction products as target. This apyrase-mediated microfluidic primer extension approach combines the rapid binding kinetics of homogeneous assays of suspended microbeads array, the liquid handling capability of microfluidics, and the fluorescence detection sensitivity of quantum dots to provide a platform for single-base analysis with small reagent consumption, short assay time, and parallel detection.  相似文献   

3.
4.
Receptor binding of HIV to the CD4 molecule is required for efficient infection of T cells, but the post-binding steps that result in penetration of HIV are not well understood. CD4 is induced to internalize upon T cell activation, and mAb to CD4 modify signal transduction and T cell activation as does HIV in some systems. It is not known whether HIV binding triggers CD4 endocytosis or whether signal transduction events are required for penetration. Selected inhibitors of signal transduction were evaluated for their effects on penetration using two assays that are dependent on penetration. After short term exposure to inhibitor and HIV, cells were analyzed for reverse-transcribed HIV DNA (DNA amplification assay), or productive infection is monitored (infectivity assay). Viral penetration was tested in the presence of H7 (protein kinase C inhibition), EGTA (extracellular Ca2+ chelation), cyclosporine A (inhibition of Ca2+/calmodulin-dependent activation), or pertussis toxin (inhibition of G protein function). All agents were used at concentrations that were inhibitory for their respective signal transduction pathways. None of the inhibitors affected viral penetration. We tracked the CD4 molecule with fluorescent probes that do not interfere with HIV binding in a system where CD4 T cells were saturated with HIV and the penetration event was relatively synchronized. Under conditions where detection of CD4 was more sensitive than the detection of HIV, HIV internalization was readily detected but CD4 internalization was not.  相似文献   

5.
6.
We demonstrate the use of silver plasmon resonant particles (PRPs), as reporter labels, in a microarray-based DNA hybridization assay in which we screen for a known polymorphic site in the breast cancer gene BRCA1. PRPs (40-100 nm in diameter) image as diffraction-limited points of colored light in a standard microscope equipped with dark-field illumination, and can be individually identified and discriminated against background scatter. Rather than overall intensity, the number of PRPs counted in a CCD image by a software algorithm serves as the signal in these assays. In a typical PRP hybridization assay, we achieve a detection sensitivity that is approximately 60 x greater than that achieved by using fluorescent labels. We conclude that single particle counting is robust, generally applicable to a wide variety of assay platforms, and can be integrated into low-cost and quantitative detection systems for single nucleotide polymorphism analysis.  相似文献   

7.
There is a growing demand to integrate biosensors with microfluidics to provide miniaturized platforms with many favorable properties, such as reduced sample volume, decreased processing time, low cost analysis and low reagent consumption. These microfluidics-integrated biosensors would also have numerous advantages such as laminar flow, minimal handling of hazardous materials, multiple sample detection in parallel, portability and versatility in design. Microfluidics involves the science and technology of manipulation of fluids at the micro- to nano-liter level. It is predicted that combining biosensors with microfluidic chips will yield enhanced analytical capability, and widen the possibilities for applications in clinical diagnostics. The recent developments in microfluidics have helped researchers working in industries and educational institutes to adopt some of these platforms for point-of-care (POC) diagnostics. This review focuses on the latest advancements in the fields of microfluidic biosensing technologies, and on the challenges and possible solutions for translation of this technology for POC diagnostic applications. We also discuss the fabrication techniques required for developing microfluidic-integrated biosensors, recently reported biomarkers, and the prospects of POC diagnostics in the medical industry.  相似文献   

8.
9.
We have developed a novel linker-primer PCR assay for the detection and quantification of integrated human immunodeficiency virus type 1 (HIV) DNA. This assay reproducibly allowed the detection of 10 copies of integrated HIV DNA, in a background of 2 x 10(5) cell equivalents of human chromosomal DNA, without amplifying extrachromosomal HIV DNA. We have used this assay and a near-synchronous one-step T-cell infection model to investigate the kinetics of viral DNA accumulation following HIV infection. We report here that integrated HIV DNA started accumulating 1 h after the first appearance of extrachromosomal viral DNA and accounted for approximately 10% of the total HIV DNA synthesized in the first round of viral replication. These results highlight the efficient nature of integrase-mediated HIV integration in infected T cells.  相似文献   

10.
11.
Apoptosis can be routinely characterized using biomolecular markers such as in the TUNEL and the annexin V assays or by using fluorescent caspase substrates. Apoptosis can also be semi-quantitatively characterized using microscopy, which targets morphological features such as cell rounding, nuclear condensation and fragmentation as well as cell membrane blebbing. This label-free approach provides a limited resolution for the evolution of these events in time and relies heavily on subjective identification of the morphological features. Here we propose a label-free assay based on surface plasmon resonance (SPR) detection of minute morphology changes occurring as a result of apoptosis induction in an endothelial cell model (EA.hy926). At first, annexin V assays confirmed that our cellular model was responsive to TRAIL over a 12-hour period. Then, we show that SPR allows accurate monitoring of apoptosis by measuring (1) the duration of the latency period during which the apoptotic signal is integrated by the initiator caspases and transmitted to the executioner caspases, (2) the rate of the execution phase in which death substrates are cleaved and morphological changes occur, and (3) the total extent of apoptosis. Using these parameters, we characterized the responses obtained with TRAIL (EA.hy926, HeLa, AD-293) and the anti-Fas antibody (HeLa) for the extrinsic pathways and UV exposure (HeLa) for the intrinsic pathways. By comparing the SPR time-course of apoptosis with phase contrast micrographs, we demonstrate that the cell morphological hallmarks of apoptosis are the major contributors to the SPR signal. Altogether, our results validate the use of SPR as an accurate label-free assay for the real-time monitoring of apoptosis-triggered cell morphological changes.  相似文献   

12.
Here we describe the development and validation of a highly sensitive assay of antigen-specific IFN-γ production using real time quantitative PCR (qPCR) for two reporters--monokine-induced by IFN-γ (MIG) and the IFN-γ inducible protein-10 (IP10). We developed and validated the assay and applied it to the detection of CMV, HIV and Mycobacterium tuberculosis (MTB) specific responses, in a cohort of HIV co-infected patients. We compared the sensitivity of this assay to that of the ex vivo RD1 (ESAT-6 and CFP-10)-specific IFN-γ Elispot assay. We observed a clear quantitative correlation between the two assays (P<0.001). Our assay proved to be a sensitive assay for the detection of MTB-specific T cells, could be performed on whole blood samples of fingerprick (50 uL) volumes, and was not affected by HIV-mediated immunosuppression. This assay platform is potentially of utility in diagnosis of infection in this and other clinical settings.  相似文献   

13.
Allergen microarrays are under development for a component‐resolved diagnosis of Type I (IgE‐mediated) allergies. Here we report an improved microarray coupled to microfluidics for the detection of allergen specific immunoglobulin E (IgE). The signal intensity for IgE detection in serum has been improved by using glass slides coated with a novel poly[DMA‐co‐NAS] brush copolymer which is able to immobilize allergens in their native conformation and by carrying out the incubation step in dynamic conditions. The assay, fully automated, was performed in a microcell, using a software‐controlled fluidic processor, to bring assay reagents on the surface of the array. Microfluidics turns the binding between serum immunoglobulins and immobilized allergens from a diffusion‐limited to a kinetic‐limited process by ensuring an efficient mixing of serum samples on the surface of the microarray. As a result of this, the binding of high affinity IgE antibodies is enhanced whereas that of low affinity IgG antibodies, which are present at higher concentration, is impaired paving the way to more accurate and sensitive results.  相似文献   

14.
The integration of semiconductor nanoparticle quantum dots (QDs) into a modular, microfluidic biosensor for the multiplexed quantitation of three important cancer markers, carcinoembryonic antigen (CEA), cancer antigen 125 (CA125), and Her-2/Neu (C-erbB-2) was achieved. The functionality of the integrated sample processing, analyte capture and detection modalities was demonstrated using both serum and whole saliva specimens. Here, nano-bio-chips that employed a fluorescence transduction signal with QD-labeled detecting antibody were used in combination with antigen capture by a microporous agarose bead array supported within a microfluidics ensemble so as to complete the sandwich-type immunoassay. The utilization of QD probes in this miniaturized biosensor format resulted in signal amplification 30 times relative to that of standard molecular fluorophores as well as affording a reduction in observed limits of detection by nearly 2 orders of magnitude (0.02 ng/mL CEA; 0.11 pM CEA) relative to enzyme-linked immunosorbent assay (ELISA). Assay validation studies indicate that measurements by the nano-bio-chip system correlate to standard methods at R2 = 0.94 and R2 = 0.95 for saliva and serum, respectively. This integrated nano-bio-chip assay system, in tandem with next-generation fluorophores, promises to be a sensitive, multiplexed tool for important diagnostic and prognostic applications.  相似文献   

15.

Introduction

Early infant diagnosis (EID) and prompt linkage to care are critical to minimise the high morbidity and mortality associated with infant HIV infection. Attrition in the “EID cascade” is common; however, point-of-care (POC) EID assays with same-day result could facilitate prompt linkage of HIV-infected infant to treatment. Despite a number of POC EID assays in development, few have been independently evaluated and data on new technologies are urgently needed to inform policy.

Methods

We compared Alere q 1/2 Detect POC system laboratory test characteristics with the local standard of care (SOC), Roche CAP/CTM HIV-1 qualitative PCR in an independent laboratory-based evaluation in Cape Town, South Africa. Routinely EID samples collected between November 2013 and September 2014 were each tested by both SOC and POC systems. Repeat testing was done to troubleshoot any discrepancy between POC and SOC results.

Results

Overall, 1098 children with a median age of 47 days (IQR, 42–117) were included. Birth PCR (age <7 days) comprised of 8% (n = 92) tests while 56% (n = 620) of children tested as part of routine EID (ages 6–14 weeks). In the overall direct comparison, Alere q Detect achieved sensitivity of 95.5% (95% CI, 91.7–97.9%) and a specificity of 99.8% (95% CI, 99.1–100%). Following repeat testing of discordant samples and exclusion of any inconclusive results, the POC assay sensitivity and specificity were 96.9% (95% CI 93.4–98.9%) and 100% (lower 95% CI 98%) respectively. Among birth PCR tests the POC assay had slightly lower sensitivity (93.3% vs 96.5% in routine EID) and higher assay error rate (10% vs 5% in samples of older children, p = 0.04).

Conclusion

Our results indicate this POC assay performs well for EID in the laboratory. The high specificity and thus high positive predictive value would suggest a positive POC result may be adequate for immediate infant ART initiation. While POC testing for EID may have particular utility for birth testing at delivery facilities, the lower sensitivity and error rate requires further attention, as does field implementation of POC EID technologies in other clinical care settings.  相似文献   

16.
Small volume fluid handling in single and multiphase microfluidics provides a promising strategy for efficient bio-chemical assays, low-cost point-of-care diagnostics and new approaches to scientific discoveries. However multiple barriers exist towards low-cost field deployment of programmable microfluidics. Incorporating multiple pumps, mixers and discrete valve based control of nanoliter fluids and droplets in an integrated, programmable manner without additional required external components has remained elusive. Combining the idea of punch card programming with arbitrary fluid control, here we describe a self-contained, hand-crank powered, multiplex and robust programmable microfluidic platform. A paper tape encodes information as a series of punched holes. A mechanical reader/actuator reads these paper tapes and correspondingly executes operations onto a microfluidic chip coupled to the platform in a plug-and-play fashion. Enabled by the complexity of codes that can be represented by a series of holes in punched paper tapes, we demonstrate independent control of 15 on-chip pumps with enhanced mixing, normally-closed valves and a novel on-demand impact-based droplet generator. We demonstrate robustness of operation by encoding a string of characters representing the word “PUNCHCARD MICROFLUIDICS” using the droplet generator. Multiplexing is demonstrated by implementing an example colorimetric water quality assays for pH, ammonia, nitrite and nitrate content in different water samples. With its portable and robust design, low cost and ease-of-use, we envision punch card programmable microfluidics will bring complex control of microfluidic chips into field-based applications in low-resource settings and in the hands of children around the world.  相似文献   

17.
Giant magnetoresistive biochip for DNA detection and HPV genotyping   总被引:2,自引:0,他引:2  
A giant magnetoresistive (GMR) biochip based on spin valve sensor array and magnetic nanoparticle labels was developed for inexpensive, sensitive and reliable DNA detection. The DNA targets detected in this experiment were PCR products amplified from Human Papillomavirus (HPV) plasmids. The concentrations of the target DNA after PCR were around 10nM in most cases, but concentrations of 10pM were also detectable, which is demonstrated by experiments with synthetic DNA samples. A mild but highly specific surface chemistry was used for probe oligonucleotide immobilization. Double modulation technique was used for signal detection in order to reduce the 1/f noise in the sensor. Twelve assays were performed with an accuracy of approximately 90%. Magnetic signals were consistent with particle coverage data measured with Scanning Electron Microscopy (SEM). More recent research on microfluidics showed the potential of reducing the assay time below one hour. This is the first demonstration of magnetic DNA detection using plasmid-derived samples. This study provides a direct proof that GMR sensors can be used for biomedical applications.  相似文献   

18.
Surface plasmon resonance (SPR) biosensor formats using gold nanoparticle or protein signal amplification for the sensitive assay of small molecules were developed using progesterone as a model compound. Progesterone was immobilized to a dextran surface in the Biacore biosensor through in situ covalent immobilization using an oligoethylene glycol linker attached to the 4 position of the steroid. This surface produced stable antibody binding for in excess of 1100 assay cycles. Using this surface, assays were developed for progesterone using 10- and 20-nm gold-streptavidin labels attached to biotinylated monoclonal antibody in both label prebinding and sequential binding formats. Prelabeling formats gave no signal enhancement but produced assays with limits of detection of 143 pg/ml, compared with approximately 1 ng/ml in previous studies. Sequential binding formats gave signal enhancements of 2.2-fold over the monoclonal antibody and a limit of detection of 23.1 pg/ml. It was found that secondary antibody labeling gave 8.1-fold signal enhancements and a limit of detection of 20.1 pg/ml, whereas use of secondary antibody-25 nm gold complexes provided more signal enhancement (13-fold) and a further improvement in limit of detection of 8.6 pg/ml.  相似文献   

19.
The advances in genomics and proteomics have unveiled an exhaustive catalogue of biomarkers that can potentially be used as diagnostic and prognostic indicators of genetic and infectious diseases. Current thrust in biosensor development is towards rapid, real-time, label-free and highly sensitive detection of the indicative biomarkers. While surface plasmon resonance imaging (SPRi) biosensors could potentially be the best suited candidate for biomarker-based diagnosis, important milestones need to be reached. Commercially available SPRi instrumentation is currently limited by the flow-cell technology to serial-sample processing and has limited sensitivity for the detection of markers present at low concentration. In this paper, we have implemented an approach to enhance sample handling and increase the sensitivity of the SPRi detection technique. We have developed a digital microfluidic platform with an integrated nanostructured biosensor interface that allows for rapid, ultra-low volume, sensitive, and automated on-chip SPRi detection of DNA hybridization reactions. Through the exploitation of electromagnetic properties of nanofabricated periodic gold nanoposts, SPRi signal was increased by 200% with the estimated limit of detection of 500 pM (90 attomoles). Using the versatile fluidic manipulation provided by the digital microfluidics, rapid and parallel target identification was achieved on multiple array elements within 1 min using 180 nL sample volume. By delivering multiple target analytes in individually addressable low volume droplets, without external pumps and fluidic interconnects, the overall assay time, cost and complexity was reduced. The proposed platform allows extreme versatility in the manipulation of precious low volume samples which makes this technology very suitable for diagnostic applications.  相似文献   

20.
Correlating Two Viral Load Assays with Known Detection Limits   总被引:1,自引:0,他引:1  
A timely objective common to many HIV studies involves assessing the correlation between two different measures of viral load obtained from each of a sample of patients. This correlation has scientific utility in a number of contexts, including those aimed at a comparison of competing assays for quantifying virus and those aimed at determining the level of association between viral loads in two different reservoirs using the same assay. A complication for the analyst seeking valid point and interval estimates of such a correlation is the fact that both variables may be subject to left censoring due to values below assay detection limits. We address this problem using a bivariate normal likelihood that accounts for left censoring of two variables that may have different detection limits. We provide simulation results to evaluate sampling properties of the resulting correlation estimator and compare it with ad hoc estimators in the presence of nondetects. In an effort to obtain improved confidence interval properties relative to the Wald approach, we evaluate and compare profile likelihood-based intervals. We apply the methods to HIV viral load data on women and infants from a trial in Bangkok, Thailand, and we discuss an extension of the original model to accommodate interval censoring arising due to the study design.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号