首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
IntroductionSentinel node biopsy is a procedure used for axillary nodal staging in breast cancer surgery. The process uses radioactive 99mTc isotope for mapping the sentinel node(s) and all the staff involved in the procedure is potentially exposed to ionizing radiation. The colloid for radiolabelling (antimone-sulphide) with 99mTc isotope (half-life 6 h) is injected into the patient breast. The injection has activity of 18.5 MBq. The surgeon removes the primary tumor and detects active lymph nodes with gamma detection unit. The tumor as well as the active nodal tissue is transferred to pathologist for the definitive findings. The aim of the study was to measure dose equivalents to extremities and whole body for all staff and suggest practice improvement in order to minimize exposure risk.Materials and methodsThe measurements of the following operational quantities were performed: Hp(10) personal dose equivalent to whole body and Hp(0.07) to extremities for staff as well as ambiental dose for operating theatre and during injection.Hp(0.07) were measured at surgeon’s finger by ring thermoluminescent dosimeter (TLD) type MTS-N, and reader RADOS RE2000. Surgeon and nurse were wearing TLD personal dosimeter at the chest level. Anesthesiologist and anesthetist were wearing electronic personal dosimeters, while pathologist was wearing ring TLD while manipulating tissue samples.Electronic dosimeters used were manufactured by Polimaster, type PM1610.All TLD and electronic dosimeters data were reported, including background radiation. Background radiation was also monitored separately. Personal TLDs are standard for this type of personal monitoring, provided by accredited laboratory.Measurements of ambiental dose in workplaces of other staff involved around the patient was performed before the surgery took place, by calibrated survey meters manufactured by Atomtex, type 1667.The study involved two surgeons and one pathologist, two anesthesiologists and three anesthetists during two months period.Results and discussionThe doses received by all staff are evaluated using passive and active personal dosimeters and ambiental dose monitors and practice was improved based on results collected. Average annual whole body dose for all staff involved in the procedure was less than 0.8 mSv. Extremity dose equivalents to surgeon and pathologist were far below the limits set for professionally exposed (surgeon) and for public (pathologist).ConclusionsAlthough has proven to be very safe for all staff, additional measures for radiation protection, in accordance to ALARA principle (As Low As Reasonably Achievable) should be conducted. The recommendations for practice improvement with respect to radiation protection were issued.  相似文献   

2.
PurposeTo determine the eye lens dose of the Interventional Cardiology (IC) personnel using optically stimulated luminescent dosimeter (OSLD) and the prevalence and risk of radiation – associated lens opacities in Thailand.Methods and results48 IC staff, with age- and sex- matches 37 unexposed controls obtained eye examines. Posterior lens change was graded using a modified Merriam-Focht technique by two independent ophthalmologists. Occupational exposure (mSv) was measured in 42 IC staff, using 2 OSLD badges place at inside lead apron and at collar. Annual eye lens doses (mSv) were also measured using 4 nanoDots OSL placed outside and inside lead glass eyewear. The prevalence of radiation-associated posterior lens opacities was 28.6% (2/7) for IC, 19.5% (8/41) for nurses, and 2.7% (1/37) for controls. The average and range of annual whole body effective dose, Hp(10), equivalent dose at skin of the neck, Hp(0.07) and equivalent dose at eye lens, Hp(3) were 0.80 (0.05–6.79), 5.88 (0.14–35.28), and 5.73 (0.14–33.20) mSv respectively. The annual average and range of eye lens dose using nano Dots OSL showed the outside lead glass eyewear on left and right sides as 8.06 (0.17–32.45), 3.55(0.06–8.04) mSv and inside left and right sides as 3.91(0.05–14.26) and 2.44(0.06–6.24) mSv respectively.ConclusionEye lens doses measured by OSLD badges and nano Dot dosimeter as Hp(10), Hp(0.07) and Hp(3). The eyes of the IC personnel were examined annually by two ophthalmologists for the prevalence of cataract induced by radiation.  相似文献   

3.
The practice of holding combined orthopaedic and rheumatology clinics is widespread, but no attempt has been made to assess their usefulness. In a one year prospective study patients were randomised either to a combined clinic with a rheumatologist and an orthopaedic surgeon or to a clinic with an orthopaedic surgeon alone. The details of the patients'' disease, the interview, the surgeons'' and rheumatologists'' responses, and the patients'' opinions were recorded on questionnaires. Interviews were appreciably longer in the combined clinic, and more referrals for surgery were made. The rheumatologist correctly predicted the need for surgery in 95% of cases, and his presence in the clinic was considered desirable by the surgeon, principally when the referral letter was inadequate. It is concluded that most patients with rheumatic diseases can be seen more efficiently in routine orthopaedic clinics provided a good quality letter of referral is sent.  相似文献   

4.
Occupational radiation dose of staff handling 125I assessment at the Benin radioimmunoassay laboratory, have been undertaken from October 2012 to April 2013 to determine level of radiation safety. Equivalent dose to skin, whole body and extremities, were measured by the mean of thermoluminescence dosimetry. Firstly, three permanent workers and two students were provided with finger ring dosimeters to wear at index finger base of both hands. Ring dosimeters were used for four months. Secondly, three permanent workers and three students were provided with badge dosimeters to wear at the chest level. Badge dosimeters were renewed monthly for six months. The exposed ring and badge dosimeters were evaluated in Ghana. Permanent workers highest average equivalent dose received at index finger base of both hands was 142.75 ± 89.54, microSV/2 months and that of students was 34.69 ± 29.23, microSV/2 months. Workers skin exposure was below one third of prescribed dose limits for permanents workers (500mSv/yr) and students (150mSv/yr). Whole body exposure, expressed in mSv/month, of permanent workers and students, respectively ranged from 0.12 to 0.23 and from 0.11 to 0.16. Radio-immuno-assay laboratory workers are weakly exposed to ionizing radiation. They are safe from deterministic effect risk.  相似文献   

5.

This work presents the exposure of hands of the personnel of a nuclear medicine department who prepare and administer 68Ga-DOTA-TATE. Dosimetry measurements were performed during three 1-week sessions, for nine production procedures. A total of 360 measurements were made by using high-sensitivity MCP-N thermoluminescent detectors. Annealed detectors were and vacuum-packed in foil and then placed on each fingertip of both hands of five radiochemists and four nurses (one detector for one fingertip). The greatest exposure to ionizing radiation was found on the non-dominant left hand of radiochemists and nurses. A maximum Hp(0.07)/A value of 49.36?±?4.95 mSv/GBq was registered for radiochemists during the 68 Ga-DOTA-DATE activity dispensing procedure. For nurses performing the radiopharmaceutical injection procedure, a corresponding maximum value of 1.28?±?0.13 mSv/GBq was measured, while the mean value for all the nurses was 0.38 mSv/GBq. The dispensing procedure accounted for approximately 60% of the total exposure of radiochemists' fingertips. Based on the results obtained it is recommended that a ring dosimeter should be routinely placed on the middle finger of the non-dominant hand of radiochemists and nurses. Furthermore, it is proposed to systematically train workers in handling open sources of ionizing radiation, with the aim of reducing the required handling time.

  相似文献   

6.
HLA class I and class II associations were examined in relation to measles virus-specific cytokine responses in 339 healthy children who had received two doses of live attenuated measles vaccine. Multivariate linear regression modeling analysis revealed suggestions of associations between the expression of DPA1*0201 (p=0.03) and DPA1*0202 (p=0.09) alleles and interleukin-2 (IL-2) cytokine production (global p-value 0.06). Importantly, cytokine production and DQB1 allele associations (global p-value 0.04) revealed that the alleles with the strongest association with IL-10 secretion were DQB1*0302 (p=0.02), DQB1*0303 (p=0.07) and DQB1*0502 (p=0.06). Measles-specific IL-10 secretion associations approached significance with DRB1 and DQA1 loci (both global p-values 0.08). Specifically, suggestive associations were found between DRB1*0701 (p=0.07), DRB1*1103 (p=0.06), DRB1*1302 (p=0.08), DRB1*1303 (p=0.06), DQA1*0101 (p=0.08), and DQA1*0201 (p=0.04) alleles and measles-induced IL-10 secretion. Further, suggestive association was observed between specific DQA1*0505 (p=0.002) alleles and measles-specific IL-12p40 secretion (global p-value 0.09) indicating that cytokine responses to measles antigens are predominantly influenced by HLA class II genes. We found no associations between any of the alleles of HLA A, B, and Cw loci and cytokine secretion. These novel findings suggest that HLA class II genes may influence the level of cytokine production in the adaptive immune responses to measles vaccine.  相似文献   

7.
OBJECTIVE--To determine if a relation exists between paternal exposure to relatively high levels of radiation in the Scottish nuclear industry and the risk of leukaemia and non-Hodgkin''s lymphoma is subsequently conceived children. DESIGN--Matched case-control study with three controls for each case. SETTING--The whole of Scotland. SUBJECTS--The fathers of 1024 children with leukaemia and 237 children with non-Hodgkin''s lymphoma diagnosed in Scotland below the age of 25 among those born in Scotland since nuclear operations began (in 1958) and the fathers of 3783 randomly chosen controls. The fathers of 80 children with leukaemia and 16 with non-Hodgkin''s lymphoma in north Cumbria were also covered since some workers at one Scottish nuclear site live over the border in that area. Details of all fathers were then matched against records of the nuclear industry. MAIN OUTCOME MEASURES--Paternal preconceptional radiation exposures, particularly relatively high levels, both lifetime and in the six and three months before conception. RESULTS--No significant excess was observed in any subgroup and there was no significant trend: fathers of three controls but no cases were exposed to lifetime preconceptional levels of 100 mSv or greater (Fisher''s exact p value 0.84). In the six months before conception, fathers of two cases and three controls received 10 mSv or more, odds ratio 2.3 (95% confidence interval 0.31 to 17.24). In the three months before conception the fathers of one case and two controls received 5 mSv or more, odds ratio 1.7 (0.10 to 30.76). The results for leukaemia and non-Hodgkin''s lymphoma combined were similar. CONCLUSIONS--No significant excess of leukaemia or of leukaemia and non-Hodgkin''s lymphoma was found at any radiation level in any preconceptional period.  相似文献   

8.
This study aims to investigate the association patterns of a small and resident population of bottlenose dolphins (Tursiops truncatus) in Bahía San Antonio (Argentina), and assess any seasonal variation in view of the reported seasonal variation in the population's grouping behavior. The estimation of social differentiation (S) was 0.29 (SE = 0.08), suggesting a homogenous society. The half‐weight index (HWI) averaged 0.23 (± 0.06), with evidence of long‐term preferred associations. However, data showed seasonal variation in the association patterns. In winter, when large groups were reported in this population, HWI values averaged 0.30 (± 0.09) with no indication of preferred or avoided associations. However, during summer, when group size was generally small, HWI values averaged 0.14 (± 0.07), with an indication of preferred/avoided associations. This study indicates that the social structure of the bottlenose dolphins in Bahía San Antonio seems relatively homogenous and flexible over time, with the formation of a random social network at times when large aggregations are formed, and a more disconnected network made up of strongly connected components when the cost of grouping is high.  相似文献   

9.
BackgroundCurrently, CBCT system is an indispensable component of radiation therapy units. Because of that, it is important in treatment planning and diagnosis. CBCT is also an crucial tool for patient positioning and verification in image-guided radiation therapy (IGRT). Therefore, it is critical to investigate the patient organ doses arising from CBCT imaging. The purpose of this study is to evaluate patient organ doses and effective dose to patients from three different protocols of Elekta Synergy XVI system for kV CBCT imaging examinations in image guided radiation therapy.Materials and methodsOrgan dose measurements were done with thermoluminescent dosimeters in Alderson RA NDO male phantom for head & neck (H&N), chest and pelvis protocols of the Elekta Synergy XVI kV CBCT system. From the measured organ dose, effective dose to patients were calculated according to the International Commission on Radiological Protection 103 report recommendations.ResultsFor H&N, chest and pelvis scans, the organ doses were in the range of 0.03–3.43 mGy, 6.04–22.94 mGy and 2.5–25.28 mGy, respectively. The calculated effective doses were 0.25 mSv, 5.56 mSv and 4.72 mSv, respectively.ConclusionThe obtained results were consistent with the most published studies in the literature. Although the doses to patient organs from the kV CBCT system were relatively low when compared with the prescribed treatment dose, the amount of delivered dose should be monitored and recorded carefully in order to avoid secondary cancer risk, especially in pediatric examinations.  相似文献   

10.
OBJECTIVES--To test the hypothesis that there is an association between childhood leukaemia and the occupational exposure of fathers to ionising radiation before a child''s conception. DESIGN--Case-control study with eight matched controls per case. SETTING--Regions of Ontario, Canada, with an operating nuclear facility. SUBJECTS--Cases were children (age 0-14) who died from or were diagnosed as having leukaemia from 1950 to 1988 and were born to mothers living in the vicinity of an operating nuclear facility. Controls were identified from birth certificates, matched by date of birth and residence at birth. There were 112 cases and 890 controls. MAIN OUTCOME MEASURES--Paternal radiation exposure was determined by a record linkage to the Canadian National Dose Registry. RESULTS--Six fathers of cases and 53 fathers of controls had had a total whole body dose > 0.0 mSv before the child''s conception, resulting in an odds ratio of 0.87 (95% confidence interval 0.32 to 2.34). There was no evidence of an increased leukaemia risk in relation to any exposure period (lifetime or six months or three months before conception) or exposure type (total whole body dose, external whole body dose, or tritium dose), except for radon exposure to uranium miners, which had a large odds ratio that was not significantly different from the null value. CONCLUSIONS--The findings of this study in Ontario did not support the hypothesis that childhood leukaemia is associated with the occupational exposure of fathers to ionising radiation before the child''s conception.  相似文献   

11.

Objectives

Analysis of discrepancies between patient and surgeon expectations before total hip arthroplasty (THA) should enable a better understanding of motives of dissatisfaction about surgery, but this question has been seldom studied. Our objectives were to compare surgeons'' and patients'' expectations before THA, and to study factors which affected surgeon-patient agreement.

Methods

132 adults (mean age 62.8+/−13.7 years, 52% men) on waiting list for THA in three tertiary care centres and their 16 surgeons were interviewed to assess their expectations using the Hospital for Special Surgery Total Hip Replacement Expectations Survey (range 0–100). Patients'' and surgeons'' answers were compared, for the total score and for the score of each item. Univariate analyses tested the effect of patients'' characteristics on surgeons'' and patients'' expectations separately, and on surgeon-patient differences.

Results

Surgeon and patient expectations'' mean scores were high (respectively 90.9+/−11.1 and 90.0+/−11.6 over 100). Surgeons'' and patients'' expectations showed no systematic difference, but there was little agreement on Bland and Altman graph and correlation coefficient was low. Patients had higher expectations than surgeons for sports. Patients rated their expectations according to trust in physician and mental quality of life, surgeons considered disability. More disabled patients and patients from a low-income professional category were often “more optimistic” than their surgeons.

Conclusion

Surgeons and patients often do not agree on what to expect from THA. More disabled patients expect better outcomes than their surgeons.  相似文献   

12.
Modern operative treatment of diseases of the bile passages requires the use of x-ray visualization of the biliary tract before, after and during operation. Nearly every surgeon uses x-ray study of the biliary tract before operation and it is widespread practice to carry out such study after operations in which a tube has been placed in the bile passages. However, there is a remarkable aversion to operative cholangiography.The usual reasons for avoiding operative cholangiography are unfamiliarity, inertia, concern over complications of the technique, and the feeling that it is unnecessary or wasteful of surgeon''s time and patient''s money. Yet the results of operative cholangiograms compare favorably with those obtained with the more customary x-ray studies of the bile ducts carried out after operation, at a time when the information gained is much less valuable in avoiding additional operations and in contributing to a smooth and rapid convalescence.  相似文献   

13.
Abstract

Manual skill is now widely recognised as an important aspect of training in surgery. However, measurement of the skill of a surgeon has in the past been rather subjective in nature, relying on the judgement of experts in the analysis of videotapes. Objective measurements can be made by analysing the velocities of a surgeon's hands during a procedure. In particular, we have found that the number of movements made during a typical procedure will decrease as the surgeon's skill increases. Velocity traces display purposeful movements corrupted by uncorrelated noise from sources such as hand tremor and measurement artefacts. However, we have found that it is possible to filter the noise effectively. Furthermore, we have shown that the skill measurement obtained by counting movements is highly robust to over or under filtering.  相似文献   

14.
PurposeThis study aimed to measure the eye lens doses received by physicians and other medical staff participating in non-vascular imaging and interventional radiology procedures in Japan.Material and methodsFrom October 2014 to March 2017, 34 physicians and 29 other medical staff engaged in non-vascular imaging and interventional radiology procedures at 18 Japanese medical facilities. These professionals wore radioprotective lead glasses equipped with small, optically stimulated luminescence dosimeters and additional personal dosimeters at the neck during a 1-month monitoring period. The Hp(3) and the Hp(10) and Hp(0.07) were obtained from these devices, respectively. The monthly Hp(3), Hp(10), and Hp(0.07) for each physician and other medical staff member were then rescaled to a 12-month period to enable comparisons with the revised occupational equivalent dose limit for the eye lens.ResultsAmong physicians, the average annual Hp(3) values measured by the small luminescence dosimeters on radioprotective glasses were 25.5 ± 38.3 mSv/y (range: 0.4–166.8 mSv/y) and 9.3 ± 16.6 mSv/y (range: 0.3–82.4 mSv/y) on the left and right sides, respectively. The corresponding values for other medical staff were 3.7 ± 3.1 mSv/y (range: 0.4–10.4 mSv/y) and 3.2 ± 2.7 mSv/y (range: 0.5–11.5 mSv/y), respectively.ConclusionsThe eye lens doses incurred by physicians and other medical staff who engaged in non-vascular imaging and interventional radiology procedures in Japan were provided. Physicians should wear radioprotective glasses and use additional radioprotective devices to reduce the amount of eye lens doses they receive.  相似文献   

15.
Electrosurgical units (ESUs) commonly used in operating suites employ radiofrequency (RF) energy for cutting and coagulation, and operate at different frequencies in the range 0.3–5 MHz. Around the electrode and cables, electric and magnetic fields at similar frequencies will be generated, and the surgeon using the ESU will therefore be exposed to these electromagnetic fields. In this study we have measured the levels of RF fields near the lead wires of two electrosurgical units, BARD 3000 operating at a fixed frequency of 0.5 MHz, and ERBE ICC 350 with a frequency range from 0.3 to 1 MHz. Electric fields were measured at distances from 5–30 cm from the lead wire. Measurements were done with the ESU both cutting and coagulating, and power levels ranging from 10–100 W. The magnetic field outside the lead wire was calculated from the measured current through the leads using standard theory. Using those measurements as a base, the calculated local exposure of the surgeon's hand was estimated to exceed 15 kV/m for the electric field and the corresponding value for the magnetic field was 16 µT. These calculations exceed the suggested international reference levels at 0.5 MHz (610 V/m and 4 µT, respectively).  相似文献   

16.
S. S. Hanna  D. W. Jirsch 《CMAJ》1979,120(11):1387-1391
In managing a colonic or rectal injury the surgeon must decide whether it is acceptable to have feces passing over a suture line or anastomosis. If it is, resection and anastomosis or simple oversewing of the bowel can be done. If it is not, there are four choices: (a) closure of the wound, drainage and proximal diversion; (b) primary closure or resection and anastomosis of the wound with exteriorization; (c) formation of a double-barrelled colostomy; and (d) resection of the injured colon with formation of an end-colostomy and a mucosal fistula or a Hartmann procedure. The surgeon''s choice should be dictated by the severity of the injury, the degree of fecal contamination and the general condition of the patient.  相似文献   

17.
OBJECTIVE--To examine whether the observed excess of childhood leukaemia and lymphoma near the Sellafield nuclear plant is associated with established risk factors or with factors related to the plant. DESIGN--A case-control study. SETTING--West Cumbria health district. SUBJECTS--52 Cases of leukaemia, 22 of non-Hodgkin''s lymphoma, and 23 of Hodgkin''s disease occurring in people born in the area and diagnosed there in 1950-85 under the age of 25 and 1001 controls matched for sex and date of birth taken from the same birth registers as the cases. MAIN OUTCOME MEASURES--Antenatal abdominal x ray examinations, viral infections, habit factors, proximity to and employment characteristics of parents at Sellafield. RESULTS--Expected associations with prenatal exposure to x rays were found, but little information was available on viral illnesses. Relative risks for leukaemia and non-Hodgkin''s lymphoma were higher in children born near Sellafield and in children of fathers employed at the plant, particularly those with high radiation dose recordings before their child''s conception. For example, the relative risks compared with area controls were 0.17 (95% confidence interval 0.05 to 0.53) for being born further than 5 km from Sellafield 2.44 (1.04 to 5.71) for children of fathers employed at Sellafield at their conception, and 6.42 (1.57 to 26.3) for children of fathers receiving a total preconceptual ionising radiation dose of 100 mSv or more. Other factors, including exposure to x rays, maternal age, employment elsewhere, eating seafood, and playing on the beach did not explain these relationships. Focusing on Seascale, where the excess incidence has predominantly been reported, showed for the four out of five cases of leukaemia and one case of non-Hodgkin''s lymphoma whose fathers were employed at Sellafield and for whom dose information was obtained that the fathers of each case had higher radiation doses before their child''s conception than all their matched control fathers; the father of the other Seascale case (non-Hodgkin''s lymphoma) was not employed at the plant. These results seem to explain statistically the geographical association. For Hodgkin''s disease neither geographical nor employment associations with Sellafield were found. CONCLUSIONS--The raised incidence of leukaemia, particularly, and non-Hodgkin''s lymphoma among children near Sellafield was associated with paternal employment and recorded external dose of whole body penetrating radiation during work at the plant before conception. The association can explain statistically the observed geographical excess. This result suggests an effect of ionising radiation on fathers that may be leukaemogenic in their offspring, though other, less likely, explanations are possible. There are important potential implications for radiobiology and for protection of radiation workers and their children.  相似文献   

18.
Objectives To calculate in-hospital mortality after lobectomy for primary lung cancer in the United Kingdom; to explore the validity of using such data to assess the quality of UK thoracic surgeons; and to investigate the relation between in-hospital mortality and the number of procedures performed by surgeons.Design Retrospective study.Setting 36 departments dealing with thoracic surgery in UK hospitals.Participants 4028 patients who had undergone lobectomy for primary lung cancer by one of 102 surgeons.Main outcome measures In-hospital mortality in relation to individual surgeons, among all patients, and among each of five groups of patients defined by the number of operations performed by the surgeon.Results 103 patients (2.6%, 95% confidence interval 2.1% to 3.1%) died after surgery during the same hospital admission. No significant difference was found for in-hospital mortality between the five groups.Conclusions The number of procedures performed by a thoracic surgeon is not related to in-hospital mortality. Reporting data on in-hospital mortality after lobectomy for primary lung cancer is a poor tool for measuring a surgeon''s performance.  相似文献   

19.
《Small Ruminant Research》2010,92(2-3):170-177
Genetic parameters were estimated for birth weight (BW), weaning weight (WW), yearling weight (YW), average daily gain from birth to weaning (ADG1) and average daily gain from weaning to yearling (ADG2) in Moghani sheep. Maximum number of data was 4237 at birth, but only 1389 records at yearling were investigated. The data was collected from 1995 to 2007 at the Breeding Station of Moghani sheep in Jafarabad, Moghan, Iran. (Co)Variance components and genetic parameters were estimated with different models which including direct effects, with and without maternal additive genetic effects as well as maternal permanent environmental effects using restricted maximum likelihood (REML) method. The most appropriate model for each trait was determined based on likelihood ratio tests and Akaike's Information Criterion (AIC). Maternal effects were important only for pre-weaning traits. Direct heritability estimates for BW, ADG1, WW, ADG2 and YW were 0.07, 0.08, 0.09, 0.09 and 0.17, respectively. Fractions of variance due to maternal permanent environmental effects on phenotypic variance were 0.08 for ADG1. Maternal heritability estimates for BW and WW were 0.18 and 0.06, respectively. Multivariate analysis was performed using the most appropriate models obtained in univariate analysis. Direct genetic correlations among studied traits were positive and ranged from 0.37 for BW–ADG2 to 0.85 for ADG1–YW. Maternal genetic correlation estimate between BW and WW was 0.33. Phenotypic and environmental correlation estimates were generally lower than those of genetic correlation. Low direct heritability estimates imply that mass selection for these traits results in slow genetic gain.  相似文献   

20.
Precopulatory courtship plays an essential role in the insemination process and influences postcopulatory behavior between males and females. Male precopulatory oral stimulation of female genitals is rare for invertebrates. Here, we describe an intriguing oral sexual courtship in a cryptic desert beetle Platyope mongolica Faldermann. The males repeatedly contact the female''s genitals using their mouths to gain consent to mate. Furthermore, the rate at which males contact the female''s genitals relates to the copulation success in a series of observations. However, interference in oral sexual contacts decreased the proportion of successful copulation. Further no‐choice tests found homosexual behavior between males with antenna removed. We report the precopulatory oral sexual behavior and its important role for copulation success in P. mongolica for the first time. These findings highlight the significance of oral sexual courtship in sexual selection.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号