1.

Purpose

To investigate the feasibility of an intravascular imaging antenna to image abdominal aorta atherosclerotic plaque in swine using 3.0T magnetic resonance imaging (MRI).

Methods

Atherosclerotic model was established in 6 swine. After 8 months, swine underwent an MR examination, which was performed using an intravascular imaging guide-wire, and images of the common iliac artery and the abdominal aorta were acquired. Intravascular ultrasound (IVUS) was performed in the right femoral artery; images at the same position as for the MR examination were obtained. The luminal border and external elastic membrane of the targeted arteries were individually drawn in the MR and IVUS images. After co-registering these images, the vessel, lumen, and vessel wall areas and the plaque burden in the same lesions imaged using different modalities were calculated and compared. The diagnostic accuracy of intravascular MR examination in delineating the vessel wall and detecting plaques were analyzed and compared using IVUS.

Results

Compared with IVUS, good agreement was found between MRI and IVUS for delineating vessel, lumen, and vessel wall areas and plaque burden (r value: 0.98, 0.95, 0.96 and 0.91, respectively; P<0.001).

Conclusion

Compared with IVUS, using an intravascular imaging guide-wire to image deep seated arteries allowed determination of the vessel, lumen and vessel wall areas and plaque size and burden. This may provide an alternative method for detecting atherosclerotic plaques in the future.  相似文献   

2.

Rationale

There is growing evidence that obstructive sleep apnea is associated with coronary artery disease. However, there are no data on the course of coronary stenosis after percutaneous coronary intervention in patients with obstructive sleep apnea.

Objectives

To determine whether sleep apnea is associated with increased late lumen loss and restenosis after percutaneous coronary intervention.

Methods

78 patients with coronary artery disease who underwent elective percutaneous coronary intervention were divided in 2 groups: 43 patients with an apnea hypopnea – Index < 10/h (group I) and 35 pt. with obstructive sleep apnea and an AHI > 10/h (group II). Late lumen loss, a marker of restenosis, was determined using quantitative coronary angiography after 6.9 ± 3.1 months.

Main results

Angiographic restenosis (>50% luminal diameter), was present in 6 (14%) of group I and in 9 (25%) of group II (p = 0.11). Late lumen loss was significant higher in pt. with an AHI > 10/h (0.7 ± 0.69 mm vs. 0.38 ± 0.37 mm, p = 0.01). Among these 35 patients, 21(60%) used their CPAP devices regularly. There was a marginally lower late lumen loss in treated patients, nevertheless, this difference did not reach statistical significance (0.57 ± 0.47 mm vs. 0.99 ± 0.86 mm, p = 0.08). There was no difference in late lumen loss between treated patients and the group I (p = 0.206).

Conclusion

In summary, patients with OSA and coronary artery disease have a higher degree of late lumen loss, which is a marker of restenosis and vessel remodeling after elective percutaneous intervention.  相似文献   

3.

Background

Percutaneous coronary intervention (PCI) stent inflation pressure correlates to angiographic lumen improvement and stent expansion but the relation to outcome is not clarified. Using comprehensive registry data our aim was to evaluate how stent inflation pressure influences restenosis, stent thrombosis and death following PCI.

Methods

We evaluated all consecutive coronary stent implantations in Sweden during 46 months from 2008 using data from the Swedish Coronary Angiography and Angioplasty Registry (SCAAR). We used logistic regression and Cox proportional hazard modeling to estimate risk of outcomes with different balloon pressures.

Results

In total, 93 697 stents were eligible for analysis and divided into five different pressure interval groups: ≤15 atm, 16–17 atm, 18–19 atm, 20–21 atm and ≥22 atm. The risks of stent thrombosis and restenosis were significantly higher in the ≤15 atm, 18–19 atm and ≥22 atm groups (but not in the 16–17 atm group) compared to the 20–21 atm group. There were no differences in mortality. Post-dilatation was associated with a higher restenosis risk ratio (RR) of 1.22 (95% confidence interval (CI) 1.14–1.32, P<0.001) but stent thrombosis did not differ statistically between procedures with or without post-dilatation. The risk of death was lower following post-dilatation (RR 0.81 (CI 0.71–0.93) P = 0.003) and the difference compared to no post-dilatation was seen immediately after PCI.

Conclusion

Our retrospective study of stent inflation pressure identified a possible biological pattern—the risks of stent thrombosis and of restenosis appeared to be higher with low and very high pressures. Post-dilatation might increase restenosis risk.  相似文献   

4.

Background

Carotid angioplasty and stenting (CAS) may currently be recommended especially in younger patients with a high-grade carotid artery stenosis. However, evidence is accumulating that in-stent restenosis (ISR) could be an important factor endangering the long-term efficacy of CAS. The aim of this study was to investigate the influence of inflammatory serum markers and procedure-related factors on ISR as diagnosed with duplex sonography.

Methods

We analyzed 210 CAS procedures in 194 patients which were done at a single university hospital between May 2003 and June 2010. Periprocedural C-reactive protein (CRP) and leukocyte count as well as stent design and geometry, and other periprocedural factors were analyzed with respect to the occurrence of an ISR as diagnosed with serial carotid duplex ultrasound investigations during clinical long-term follow-up.

Results

Over a median of 33.4 months follow-up (IQR: 14.9–53.7) of 210 procedures (mean age of 67.9±9.7 years, 71.9% male, 71.0% symptomatic) an ISR of ≥70% was detected in 5.7% after a median of 8.6 months (IQR: 3.4–17.3). After multiple regression analysis, leukocyte count after CAS-intervention (odds ratio (OR): 1.31, 95% confidence interval (CI): 1.02–1.69; p = 0.036), as well as stent length and width were associated with the development of an ISR during follow-up (OR: 1.25, 95% CI: 1.05–1.65, p = 0.022 and OR: 0.28, 95% CI: 0.09–0.84, p = 0.010).

Conclusions

The majority of ISR during long-term follow-up after CAS occur within the first year. ISR is associated with periinterventional inflammation markers and influenced by certain stent characteristics such as stent length and width. Our findings support the assumption that stent geometry leading to vessel injury as well as periprocedural inflammation during CAS plays a pivotal role in the development of carotid artery ISR.  相似文献   

5.

Background

We sought to establish the long-term safety of drug-eluting stents compared with bare-metal stents in a usual care setting.

Methods

Using data from a prospective multicentre registry, we compared rates of death and of death or repeat revascularization during 3 years of follow-up of 6440 consecutive patients who underwent angioplasty with either drug-eluting or bare-metal stents between Apr. 1, 2003, and Mar. 31, 2006.

Results

Drug-eluting stents were inserted in 1120 patients and bare-metal stents in 5320. The drug-eluting stents were selected for patients who had a greater burden of comorbid illness, including diabetes mellitus (32.8% v. 20.8% in the bare-metal group, p < 0.001) and renal disease (7.4% v. 5.0%, p = 0.001). At 1-year follow-up, the drug-eluting stents were associated with a mortality of 3.0%, as compared with 3.7% with the bare-metal stents (adjusted odds ratio [OR] 0.62, 95% confidence interval [CI] 0.46–0.83). The rate of the composite outcome of death or repeat revascularization was 12.0% for the drug-eluting stents and 15.8% for the bare-metal stents (adjusted OR 0.40, 95% CI 0.33–0.49). In the subgroup of patients who had acute coronary syndromes, the adjusted OR for this composite outcome was 0.46 (95% CI 0.35–0.61). During the 3 years of observation, the relative risks for death and repeat revascularization varied over time. In year 1, there was an initial period of lower risk in the group with drug-eluting stents than in the group with bare-metal stents; this was followed by a shift toward outcome rates favouring bare-metal stents in years 2 and 3. The adjusted relative risk of the composite outcome of death or repeat revascularization associated with drug-eluting stents relative to bare-metal stents was 0.73 early in the first year of follow-up; it then rose gradually over time, to a peak of 2.24 at 3 years.

Interpretation

Drug-eluting stents are safe and effective in the first year following insertion. Thereafter, the possibility of longer term adverse events cannot be ruled out.Drug-eluting stents now comprise at least 85% of stents used in the United States and up to 40% or more of stents elsewhere. The overwhelming worldwide use of drug-eluting stents has, however, been tempered by the cost differential to bare-metal stents, the lack of data on long-term outcomes in large patient populations and, more recently, emerging concerns about safety because of reports of late thrombosis.1–8The use of stents has been shown to reduce the rates of repeat revascularization and restenosis after angioplasty compared with angioplasty alone.9 Despite this, the long-term efficacy of stent use has been limited by the need for repeat revascularization owing to restenosis.10 Drug-eluting stents were developed to address this problem. Both clinical trials11–20 and registry data21–25 have shown reduced rates of restenosis with drug-eluting stents up to 4 years after implantation. This advantage appears to extend to patients with acute coronary syndromes: a recent 2-year follow-up study involving 7217 patients with acute coronary syndromes suggested that rates of death were lower among patients with drug-eluting stents than among those with bare-metal stents.26The possibility of late thrombosis associated with drug-eluting stents is, however, a concern. Rates of late thrombosis have been reported to be 3.6–5.9 events per 1000 patients receiving drug-eluting stents.27 This adverse event has been the subject of a review by the US Food and Drug Administration and has captured the attention of authoritative bodies around the world.Because of concerns about the long-term safety of drug-eluting stents, we compared the rates of death and of death or repeat revascularization over 3 years among patients who received either bare-metal or drug-eluting stents during angioplasty.  相似文献   

6.
7.

Aims

Accurate computed tomography (CT)-based reconstruction of coronary morphometry (diameters, length, bifurcation angles) is important for construction of patient-specific models to aid diagnosis and therapy. The objective of this study is to validate the accuracy of patient coronary artery lumen area obtained from CT images based on intravascular ultrasound (IVUS).

Methods and Results

Morphometric data of 5 patient CT scans with 11 arteries from IVUS were reconstructed including the lumen cross sectional area (CSA), diameter and length. The volumetric data from CT images were analyzed at sub-pixel accuracy to obtain accurate vessel center lines and CSA. A new center line extraction approach was used where an initial estimated skeleton in discrete value was obtained using a traditional thinning algorithm. The CSA was determined directly without any circular shape assumptions to provide accurate reconstruction of stenosis. The root-mean-square error (RMSE) for CSA and diameter were 16.2% and 9.5% respectively.

Conclusions

The image segmentation and CSA extraction algorithm for reconstruction of coronary arteries proved to be accurate for determination of vessel lumen area. This approach provides fundamental morphometric data for patient-specific models to diagnose and treat coronary artery disease.  相似文献   

8.

Background

In-stent restenosis (ISR) remains a common life-threatening complication and some studies have shown that pioglitazone can reduce the incidence of ISR in patients with drug-eluting stents (DES) implantation. We conducted a meta-analysis to assess the effect of pioglitazone in preventing ISR after DES implantation.

Methods

Randomized controlled trials (RCTs) investigating the effects of pioglitazone for ISR after DES implantation were identified by systematic searches of multiple online databases and manual searches of related reference lists of identified trials through May 2014. The primary endpoint was the rate of ISR. Secondary endpoints included minimum lumen diameter, percentage stenosis of stented vessels, late loss, in-stent neointimal volume, target vessel revascularization (TVR), target lesion revascularization, myocardial infarction, stent thrombosis and death.

Results

Five studies, comprising 255 pioglitazone-treated patients and 245 controls, were identified in the current meta-analysis. Pioglitazone did not significantly reduce the rate of ISR (P = 0.20) with low heterogeneity (I2 = 13.3%, P = 0.32). For the secondary outcomes, pioglitazone did not substantially affect the pooled estimates of these endpoints except late loss (P = 0.01) and TVR (P = 0.04).

Conclusions

The limited evidence indicates that pioglitazone does not demonstrate markedly beneficial effect in patients subjected to coronary DES implantation. However, the results should be interpreted with care given the small sample size. Further large-scale RCTs are needed.  相似文献   

9.

Background

The relative short-, long- and overall-term efficacy and safety of sirolimus-eluting stents (SES, Cypher) compared with paclitaxel-eluting stents (PES, Taxus) in large head-to-head comparisons still remain to be defined.

Methods

We searched Pubmed, EMBASE, and the Cochrane Central Register of Controlled Trials (CENTRAL) for articles comparing outcomes of interest between SES and PES without language restriction. Short- (≤1 year), long- (>1 year), and overall-term (the longest follow-up of each study) outcomes were evaluated. The primary endpoint was target lesion revascularization (TLR). Other outcomes of interest were target vessel revascularization (TVR), myocardial infarction, all-cause death, cardiac death, stent thrombosis, major adverse cardiac events (MACEs), restenosis and late lumen loss.

Results

Seventy-six studies including more than 15000 patients in randomized controlled trials and over 70000 patients in adjusted observational studies were included. At overall-term follow-up, SES significantly reduced TLR (relative risk [RR]: 0.61; 95% confidence interval [CI]: 0.49–0.76), TVR (RR: 0.67; 95% CI: 0.54–0.83), MACE (RR: 0.79; 95% CI: 0.72–0.87), myocardial infarction (RR: 0.85; 95% CI: 0.73–0.99), in-segment restenosis (RR: 0.50; 95% CI: 0.38–0.65), and in-segment late lumen loss (weighted mean difference [WMD]: −0.19; 95% CI: −0.24–−0.14) in randomized controlled trials compared with PES. In addition, lower rates of death (RR: 0.91; 95% CI: 0.83–1.00), any stent thrombosis (RR: 0.62; 95% CI: 0.45–0.86), definite stent thrombosis (RR: 0.59; 95% CI: 0.45–0.77) were found in patients receiving SES in adjusted observational studies. Largely similar results were found at short- and long-term follow-up, and in patients with diabetes, acute myocardial infarction or long lesions.

Conclusions

SES significantly reduced the short-, long- and overall-term risk of TLR/TVR, MACE, and restenosis, and overall-term risk of myocardial infarction in randomized controlled trials, as compared with PES. Lower rates of death and stent thrombosis were also observed in observational studies in SES-treated patients.  相似文献   

10.

Background

Stent length serves as a predictor of restenosis in use of bare metal stents (BMS). This has been demonstrated in a feasibility study that used a single short BMS implant (<9 mm) in a high proportion of lesions; the study observed a low rate of restenosis.

Methods

We performed a pilot prospective study to investigate in a series of consecutive patients the immediate and long-term effects of implantation of either 1) a single short BMS for all lesions with low probability of restenosis or 2) a drug-eluting stent (DES) for all other lesions.

Results

The 200 patients studied had 236 coronary artery lesions that were treated with short BMS in 168/236 patients (71.2%) and with DES in 68/236 patients (28.8%). Angiographic success was achieved in 230/236 lesions (97.5%) and procedural success in 194/200 patients (97.0%). Restenosis occurred in 15/153 lesions (9.8%) after short BMS, in 3/62 lesions (4.8%) after DES, and in 18/215 of all lesions (8.4%) angiographically controlled after six to eight months. Target vessel revascularization was performed in 16/218 lesion (7.4%).

Conclusion

Most of the coronary artery lesions in this small group of consecutive patients were treated sufficiently with a single BMS implant. This differential approach of treating suitable lesions in medium- to large-sized vessels with a single short BMS device and treating all other lesions with a DES implant resulted in a low incidence of restenosis.  相似文献   

11.

Purpose

To demonstrate the feasibility of a miniature handheld optical coherence tomography (OCT) imager for real time intraoperative vascular patency evaluation in the setting of super-microsurgical vessel anastomosis.

Methods

A novel handheld imager Fourier domain Doppler optical coherence tomography based on a 1.3-µm central wavelength swept source for extravascular imaging was developed. The imager was minimized through the adoption of a 2.4-mm diameter microelectromechanical systems (MEMS) scanning mirror, additionally a 12.7-mm diameter lens system was designed and combined with the MEMS mirror to achieve a small form factor that optimize functionality as a handheld extravascular OCT imager. To evaluate in-vivo applicability, super-microsurgical vessel anastomosis was performed in a mouse femoral vessel cut and repair model employing conventional interrupted suture technique as well as a novel non-suture cuff technique. Vascular anastomosis patency after clinically successful repair was evaluated using the novel handheld OCT imager.

Results

With an adjustable lateral image field of view up to 1.5 mm by 1.5 mm, high-resolution simultaneous structural and flow imaging of the blood vessels were successfully acquired for BALB/C mouse after orthotopic hind limb transplantation using a non-suture cuff technique and BALB/C mouse after femoral artery anastomosis using a suture technique. We experimentally quantify the axial and lateral resolution of the OCT to be 12.6 µm in air and 17.5 µm respectively. The OCT has a sensitivity of 84 dB and sensitivity roll-off of 5.7 dB/mm over an imaging range of 5 mm. Imaging with a frame rate of 36 Hz for an image size of 1000(lateral)×512(axial) pixels using a 50,000 A-lines per second swept source was achieved. Quantitative vessel lumen patency, lumen narrowing and thrombosis analysis were performed based on acquired structure and Doppler images.

Conclusions

A miniature handheld OCT imager that can be used for intraoperative evaluation of microvascular anastomosis was successfully demonstrated.  相似文献   

12.

Background

Recent clinical studies have shown that recanalization rates are lower in stent-assisted coil embolization than in coiling alone in the treatment of cerebral aneurysms.

Objective

This study aimed to assess and compare the hemodynamic effect of stent struts and straightening of vessels by stent placement on reducing flow velocity in sidewall aneurysms, with the goal of reducing recanalization rates.

Methods

We evaluated 16 sidewall aneurysms treated with Enterprise stents. We performed computational fluid dynamics simulations using patient-specific geometries before and after treatment, with or without stent struts.

Results

Stent placement straightened vessels by a mean (±standard deviation) of 12.9°±13.1° 6 months after treatment. Placement of stent struts in the initial vessel geometries reduced flow velocity in aneurysms by 23.1%±6.3%. Straightening of vessels without stent struts reduced flow velocity by 9.6%±12.6%. Stent struts had significantly stronger effects on reducing flow velocity than straightening (P = 0.004, Wilcoxon test). Deviation of the effects was larger by straightening than by stent struts (P = 0.01, F-test). The combination of stent struts and straightening reduced flow velocity by 32.6%±12.2%. There was a trend that larger inflow angles produced a larger reduction in flow velocity by straightening of vessels (P = 0.16).

Conclusion

In sidewall aneurysms, stent struts have stronger effects (approximately 2 times) on reduction in flow velocity than straightening of vessels. Hemodynamic effects by straightening vary in each case and can be predicted by inflow angles of pre-operative vessel geometry. These results may be useful to design a treatment strategy for reducing recanalization rates.  相似文献   

13.

Objectives

Oxidized low-density lipoproteins (oxLDL) and oxidized low-density lipoprotein autoantibodies (OLAB) have been detected in human plasma and atherosclerotic lesions. OLAB appear to play a role in the clearance of oxLDL from circulation. Higher levels of OLAB appear to be associated with a reduced risk of a wide range of cardiovascular diseases. We investigated the prognostic value of plasma oxLDL and OLAB in patients undergoing primary coronary balloon angioplasty for acute ST-elevation myocardial infarction (STEMI).

Methods

Plasma oxLDL and OLAB concentrations were measured in 56 patients with acute STEMI before primary angioplasty, and then 3 days, 7 days and 1 month after the acute event. Follow-up angiography was repeated 6 months later to detect the presence of restensosis (defined as >50% luminal diameter stenosis). The thrombolysis in myocardial infarction (TIMI) risk score was calculated to determine the relationship between OLAB/oxLDL ratio and TIMI risk scores.

Results

Of the 56 patients, 18 (31%) had angiographic evidence of restenosis. Plasma OLAB concentrations were significantly lower in the restenosis group before angioplasty (181±114 vs. 335±257 U/L, p = 0.003), and at day 3 (155±92 vs. 277±185 U/L, p<0.001) and day 7 (177±110 vs. 352±279 U/L, p<0.001) after the acute event. There was no difference in oxLDL concentration between the two groups. The ratio of OLAB/oxLDL positively correlated with TIMI risk scores before angioplasty (p for trend analysis, p = 0.004), at day 3 (p = 0.008) and day 7 (p<0.001) after STEMI.

Significance

A relative deficit of OLAB, and hence likely impaired clearance of oxLDL, is associated with the risk of arterial restenosis after primary angioplasty for acute STEMI.  相似文献   

14.

Background

Data from a large patient population regarding very long-term outcomes after BMS implantation are inadequate. This study aimed to evaluate the very long-term (8–17 years) clinical and long-term (3–5 years) angiographic outcomes after intracoronary bare-metal stenting (BMS).

Methods and Results

From the Cardiovascular Atherosclerosis and Percutaneous TrAnsluminal INterventions (CAPTAIN) registry, a total of 2391 patients with 2966 lesions treated with 3190 BMSs between November 1995 and May 2004 were evaluated. In total, 1898 patients with 2364 lesions, and 699 patients with 861 lesions underwent 6-month and 3- to 5- year angiographic follow-up, respectively. During a mean follow-up period of 149±51 months, 18.6% of the patients died (including 10.8% due to cardiac death), 6.1% developed reinfarction, 16.2% had target lesion revascularization (including 81% of the patients within the first year), 14.5% underwent new lesion stenting (including 72% of the patients after 3 years), 2.4% underwent coronary bypass surgery, and 1.6% had definite stent thrombosis. The overall cardiovascular event-free survival rate was 58.5%. The 6-month angiographic study indicated a 20% restenosis rate. The minimal luminal diameter increased from 0.65±0.44 mm to 3.02±0.46 mm immediately after stenting, decreased to 2.06±0.77 mm at the 6-month follow-up, and increased to 2.27±0.68 mm at the 3- to 5-year follow-up.

Conclusions

This study provides clinical and angiographic results from a large population of patients who underwent BMS implantations after a long-term follow-up period (149±51 months). The progression of coronary atherosclerosis developed over time, and presented with new lesion required stent implantation. The follow-up angiographic findings reconfirmed the late and sustained improvement in luminal diameter between 6 months and 3–5 years.  相似文献   

15.

Background

High-resolution contrast-enhanced imaging of the murine atherosclerotic vessel wall is difficult due to unpredictable flow artifacts, motion of the thin artery wall and problems with flow suppression in the presence of a circulating contrast agent.

Methods and Results

We applied a 2D-FLASH retrospective-gated CINE MRI method at 9.4T to characterize atherosclerotic plaques and vessel wall distensibility in the aortic arch of aged ApoE−/− mice after injection of a contrast agent. The method enabled detection of contrast enhancement in atherosclerotic plaques in the aortic arch after I.V. injection of micelles and iron oxides resulting in reproducible plaque enhancement. Both contrast agents were taken up in the plaque, which was confirmed by histology. Additionally, the retrospective-gated CINE method provided images of the aortic wall throughout the cardiac cycle, from which the vessel wall distensibility could be calculated. Reduction in plaque size by statin treatment resulted in lower contrast enhancement and reduced wall stiffness.

Conclusions

The retrospective-gated CINE MRI provides a robust and simple way to detect and quantify contrast enhancement in atherosclerotic plaques in the aortic wall of ApoE−/− mice. From the same scan, plaque-related changes in stiffness of the aortic wall can be determined. In this mouse model, a correlation between vessel wall stiffness and atherosclerotic lesions was found.  相似文献   

16.

Introduction

Application of computed tomography for monitoring intracranial stents is limited because of stent-related artifacts. Our purpose was to evaluate the effect of gemstone spectral imaging on the intracranial stent and stent lumen.

Materials and Methods

In vitro, we scanned Enterprise stent phantom and a stent–cheese complex using the gemstone spectral imaging protocol. Follow-up gemstone spectral images of 15 consecutive patients with placement of Enterprise from January 2013 to September 2014 were also retrospectively reviewed. We used 70-keV, 140-keV, iodine (water), iodine (calcium), and iodine (hydroxyapatite) images to evaluate their effect on the intracranial stent and stent lumen. Two regions of interest were individually placed in stent lumen and adjacent brain tissue. Contrast-to-noise ratio was measured to determine image quality. The maximal diameter of stent markers was also measured to evaluate stent-related artifact. Two radiologists independently graded the visibility of the lumen at the maker location by using a 4-point scale. The mean of grading score, contrast/noise ratio and maximal diameter of stent markers were compared among all modes. All results were analyzed by SPSS version 20.

Results

In vitro, iodine (water) images decreased metallic artifact of stent makers to the greatest degree. The most areas of cheese were observed on iodine (water) images. In vivo, iodine (water) images had the smallest average diameter of stent markers (0.33 ± 0.17mm; P < .05) and showed the highest mean grading score (2.94 ± 0.94; P < .05) and contrast/noise ratio of in-stent lumen (160.03 ±37.79; P < .05) among all the modes.

Conclusion

Iodine (water) images can help reduce stent-related artifacts of Enterprise and enhance contrast of in-stent lumen. Spectral imaging may be considered a noninvasive modality for following-up patients with in-stent stenosis.  相似文献   

17.

Objective

To assess the therapeutic outcome after endovascular repair of iliac arterial lesions (IALs) using a self-expandable Nitinol stent graft system.

Methods

Between July 2006 and March 2013, 16 patients (13 males, mean age: 68 years) with a self-expandable Nitinol stent graft. A total of 19 lesions were treated: nine true aneurysms, two anastomotic aneurysms, two dissections, one arteriovenous fistula, two type 1B endoleaks after endovascular aneurysm repair, one pseudoaneurysm, and two perforations after angioplasty. Pre-, intra-, and postinterventional imaging studies and the medical records were analyzed for technical and clinical success and postinterventional complications.

Results

The primary technical and clinical success rate was 81.3% (13/16 patients) and 75.0% (12/16), respectively. Two patients had technical failure due to persistent type 1A endoleak and another patient due to acute stent graft thrombosis. One patient showed severe stent graft kinking on the first postinterventional day. In two patients, a second intervention was performed. The secondary technical and clinical success rate was 87.5% (14/16) and 93.8% (15/16). The minor complication rate was 6.3% (patient with painful hematoma at the access site). The major complication rate was 6.3% (patient with ipsilateral deep vein thrombosis). During median follow-up of 22.4 months, an infection of the aneurysm sac in one patient and a stent graft thrombosis in another patient were observed.

Conclusion

Endovascular repair of various IALs with a self-expandable Nitinol stent graft is safe and effective.  相似文献   

18.

Background

The introduction of drug-eluting stents (DES) has dramatically reduced restenosis rates compared with bare metal stents, but in-stent thrombosis remains a safety concern, necessitating prolonged dual anti-platelet therapy. The drug 6-Mercaptopurine (6-MP) has been shown to have beneficial effects in a cell-specific fashion on smooth muscle cells (SMC), endothelial cells and macrophages. We generated and analyzed a novel bioresorbable polymer coated DES, releasing 6-MP into the vessel wall, to reduce restenosis by inhibiting SMC proliferation and decreasing inflammation, without negatively affecting endothelialization of the stent surface.

Methods

Stents spray-coated with a bioresorbable polymer containing 0, 30 or 300 μg 6-MP were implanted in the iliac arteries of 17 male New Zealand White rabbits. Animals were euthanized for stent harvest 1 week after implantation for evaluation of cellular stent coverage and after 4 weeks for morphometric analyses of the lesions.

Results

Four weeks after implantation, the high dose of 6-MP attenuated restenosis with 16% compared to controls. Reduced neointima formation could at least partly be explained by an almost 2-fold induction of the cell cycle inhibiting kinase p27Kip1. Additionally, inflammation score, the quantification of RAM11-positive cells in the vessel wall, was significantly reduced in the high dose group with 23% compared to the control group. Evaluation with scanning electron microscopy showed 6-MP did not inhibit strut coverage 1 week after implantation.

Conclusion

We demonstrate that novel stents coated with a bioresorbable polymer coating eluting 6-MP inhibit restenosis and attenuate inflammation, while stimulating endothelial coverage. The 6-MP-eluting stents demonstrate that inhibition of restenosis without leaving uncovered metal is feasible, bringing stents without risk of late thrombosis one step closer to the patient.  相似文献   

19.

Background and Purpose

Few studies investigated the neuropsychological outcome after carotid angioplasty with stent placement (CAS), yielding partially inconsistent results. The present investigation evaluated the effect of CAS in patients with high-grade stenosis and assessed the predictive value of ischemic lesion number for postinterventional cognitive deterioration.

Methods

22 patients were tested neuropsychologically before and six weeks after CAS. Cerebral ischemic changes were assessed with diffusion weighted imaging (DWI) prior to and after angioplasty.

Results

Pre- to postinterventional cognitive performance improved significantly in terms of verbal memory (t = −2.30; p<0.05), whereas significant deterioration was noted regarding verbal memory span (t = 2.31; p<0.05). 8 (36%) persons conformed to the criteria of cognitive improvement. 6 patients (27%) were postinterventionally classified as having deficits. Analysis yielded no statistically significant correlations between lesion quantity and cognitive change.

Conclusion

Both improvement and deterioration of cognitive functioning was observed in our collective of patients, leaving the neuropsychological outcome after percutaneous transluminal angioplasty unpredictable in individual cases. The presence of acute ischemic lesions on DWI was found to be not tightly associated with cognitive dysfunction after CAS.  相似文献   

20.

Objectives

We sought to investigate angiographic indications for the use of the STENTYS technique and evaluated the long-term safety and clinical efficacy of the stent.

Background

Coronary lesions involving complex anatomy, including aneurysmatic, ectatic, or tapered vessel segments often carry a substantial risk of stent malapposition. The self-apposing stent technique may reduce the risk of stent malapposition and therefore improve clinical outcomes.

Methods

A total of 120 consecutive patients treated with the STENTYS stent were included (drug-eluting stent (DES) n?=?101, bare-metal stent (BMS) n?=?19). All lesions were scored for angiographic indications for the STENTYS stent, including aneurysms, ectasias, tapering, absolute diameters, bifurcation lesions, and saphenous vein grafts. Off-line quantitative coronary angiography analyses were performed pre-procedure and post-procedure. Five years follow-up was obtained including cardiac death, target vessel myocardial infarction (TV-MI), target vessel revascularisation, stent thrombosis, and the composite endpoint target vessel failure (cardiac death, TV-MI and target vessel revascularisation).

Results

Angiographic indications for STENTYS use were aneurysm (30%), ectasia (19%), tapering (27%), bifurcation lesions (8%), and saphenous vein graft lesions (16%) and absolute diameters (22%). Mean maximal diameter was 4.51?±?0.99?mm. At 5?year follow-up target vessel failure rates were 24.1% in the total cohort (DES 22.8% vs. BMS 33%, p?=?0.26). Definite stent thrombosis rate was 3.8% at 5?year follow-up in this cohort with complex and high-risk lesions (DES 4.5% vs. BMS 0%, p?=?0.39).

Conclusions

Angiographic indications for the use of the self-apposing stent were complex lesions with atypical coronary anatomy. Our data showed reasonable stent thrombosis rates at 5?year follow-up, considering the high-risk lesion characteristics.
  相似文献   