首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
In order to determine the active ingredients in root extracts of Panax quinquefolius (American ginseng), a gradient HPLC method involving UV photodiode array detection was applied to separate and quantify simultaneously the ginsenosides Rb1, Rb2, Rc, Rd, Re, Rf and Rg1. All ginseng saponins were baseline-resolved under the selected conditions, and the detection limits were 1.0 microg/mL or less. The method has been applied to analyse ginsenosides extracted from American ginseng cultivated in both Wisconsin and Illinois. Ginsenosides Re and Rb1 were the two main ginseng saponins in the root. The amounts of Re in 5- and 7-year Illinois-cultivated samples were greater than those found in ginseng cultivated for 3 or 4 years in Wisconsin, whereas the levels of Rb1 were greater in the younger Wisconsin samples.  相似文献   

2.
A HPLC method with UV detection at 262nm was developed to analyze inositol hexanicotinate in rat plasma. Plasma samples were extracted with an equal volume of acetonitrile, followed by dilution with mobile phase buffer (5mM phosphate buffer, pH 6.0) to eliminate any solvent effects. Inositol hexanicotinate and the internal standard (mebendazole) were separated isocratically using a mobile phase of acetonitrile/phosphate buffer (35:65, v/v, pH 6.0) at a flow rate of 1.0mL/min and a reverse-phase XTerra MS C(18) column (4.6mmx150mm, 3.5microm). The standard curve was linear over a concentration range of 1.5-100.0microg/mL of inositol hexanicotinate in rat plasma. The HPLC method was validated with intra- and inter-day precisions of 1.55-4.30% and 2.69-21.5%, respectively. The intra- and inter-day biases were -0.75 to 19.8% and 2.58-22.0%, respectively. At plasma concentrations of 1.5-100microg/mL, the mean recovery of inositol hexanicotinate was 99.6%. The results of a stability study indicated that inositol hexanicotinate was unstable in rat plasma samples, but was stable in acetonitrile extracts of rat plasma for up to 24h at 4 degrees C. The assay is simple, rapid, specific, sensitive, and reproducible and has been used successfully to analyze inositol hexanicotinate plasma concentrations in a pharmacokinetic study using the rat as an animal model.  相似文献   

3.
A selective and sensitive method for the simultaneous determination of hypericin and hyperforin--the two main active ingredients of St. John's Wort (SJW) extract--in human plasma depending on liquid/liquid-extraction and LC/MS/MS detection has been developed, validated after specifying the stability of the photosensitive hypericin in plasma samples during light exposure and applied to samples of a patient. After extraction with ethyl acetate/n-hexane in the darkness, sample extracts were chromatographed isocratically within 6 min on a Kromasil RP-18 column. The analytes were detected with tandem mass spectrometry in the selected reaction monitoring mode using an electrospray ion source. The limit of quantification was 0.05 ng/mL for hypericin and 0.035 ng/mL for hyperforin. The accuracy of the method varied between 101.9 and 114.2% and the precision ranged from 4.7 to 15.4% (S.D., batch-to-batch) for both analytes. The method was linear at least between 0.05 and 10 ng/mL for hypericin and between 0.035 and 100 ng/mL for hyperforin. Using this method hypericin and hyperforin were determined successfully in a patient over seven days following discontinuation of exposure with therapeutic doses of St. John's Wort extract.  相似文献   

4.
Yoo BC  Park GH  Okuda H  Takaku T  Kim S  Hwang WI 《Amino acids》1999,17(4):391-400
Summary Protein-arginine N-methyltransferase (protein methylase I) catalyzes methylation of arginyl residues on substrate protein posttranslationally utilizing S-adenosyl-L-methionine as the methyl donor and yields NG-methylarginine residues. Arginyl-fructose and arginyl-fructosyl-glucose from Korean red ginseng were found to inhibit protein methylase I activity in vitro. This inhibitory activity was shown to be due to arginyl moiety in the molecules, rather than that of carbohydrates. Several basic amino acids as well as polyamines were also found to inhibit protein methylase I activity. Interestingly, the intensity of the inhibitory activity was correlated with the number of amino-group in polyamines, thus, in the order of spermine > spermidine > putrescine > agmatine-sulfate, with IC50 at approximately 15 mM, 25 mM, 35 mM, and 50 mM, respectively. On the other hand, neutral amino acids or NaCI did not inhibit the enzyme activity. Lineweaver-Burk plot analysis of the protein methylase I activity in the presence of arginine and spermidine indicated that the inhibition was competitive in nature in respect to protein substrate, with the Ki values of 24.8 mM and 11.5 mM, respectively.Polyamines Abbreviations AdoMet S-adenosyl-L-methionine - PM I protein methylase I - Arg-Fru arginyl-fructose - Arg-Fru-Glu arginyl-fructosyl-glucose - PMSF phenylmethylsulfonyl fluoride - MBP myelin basic protein - hnRNP heterogeneous ribonuclear particle - TCA trichloroacetic acid - EDTA ethylenediamine tetraacetic acid  相似文献   

5.
A rapid and sensitive method for determination and screening in human plasma of talinolol is described using propranolol as the internal standard. The analytes in plasma were extracted by liquid-liquid extraction using methyl t-butyl ether. After removed and dried the upper organic phase, the extracts were reconstituted with a fixed volume of buffer of ammonium acetate and acetonitrile (60:40, v/v). The extracts were analyzed by a HPLC coupled to electrospray ionization mass spectrometry (HPLC-MS/ESI). The HPLC separation of the analytes was performed on a Phenomenex C18 (250 mmx4.6 mm, 5 microm, USA) column, with a flow rate of 0.85 mL/min. The complete elution was obtained within 5.5 min. The calibration curve was linear in the 1.0-400.0 ng/mL range for talinolol, with a coefficient of determination of 0.9996. The average extraction recovery was above 83%. The methodology recovery was between 101% and 102%. The limit of detection (LOD) was 0.3 ng/mL for talinolol. The intraday and inter-day coefficients of variation were less than 6%. This HPLC-MS/ESI procedure was used to assess the pharmacokinetics of talinolol. A single oral 50 mg dose of talinolol tablet was administered to 12 healthy Chinese volunteers, the main pharmacokinetic data are as follows: Cmax was 147.8+/-63.8 ng/mL; tmax was 2.0+/-0.7 h; t1/2 was 12.0+/-2.6 h. The method is accurate, sensitive and simple for the pharmacokinetic study of talinolol.  相似文献   

6.
A simple and specific HPLC assay for simultaneous determination of two major active components (-) epigallocatechin-3-gallate (EGCG), and (-) epicatechin-3-gallate (ECG) of tea polyphenols (TP) in rat plasma was developed and validated. Following addition of resorcinol as internal standard (IS) the analytes were isolated from rat plasma by liquid-liquid extraction with ethyl acetate. The chromatographic separation was achieved on a reversed-phase C18 column using an isocratic mobile phase consisting of 0.1% citric acid+CH(3)CN (86:14, v/v) running at flow rate of 1.5 mL/min. The effluent was monitored at a wavelength of 280 nm. EGCG, ECG and IS were well separated from each other and free from interference from blank plasma and other components in TP as well as metabolites post-dosing. The calibration curve was constructed by plotting peak area ratio of analytes to IS vs. concentration. The method showed good linearity over range of 0.5-300 microg/mL for EGCG and 0.1-60 microg/mL for ECG (r>0.999). The intra- and inter-day precision (R.S.D.) was better than 6 and 12%, respectively. Assay accuracy was better than 94.78% for both compounds. Extraction recovery at QC samples was between 85.73 and 91.93% for EGCG and 79.08 and 86.51% for ECG. The developed method was successfully used to simultaneously measure plasma concentrations of EGCG and ECG after intravenous administration of TP to rats and yielded two typical biexponential decay concentration-time curves.  相似文献   

7.
8.
A combined assay for the determination of paclitaxel, docetaxel and ritonavir in human plasma is described. The drugs were extracted from 200 μL human plasma using liquid-liquid extraction with tertiar-butylmethylether, followed by high performance liquid chromatography analysis using 10 mM ammonium hydroxide pH 10:methanol (3:7, v/v) as mobile phase. Chromatographic separation was obtained using a Zorbax Extend C(18) column. Labelled analogues of the analytes are used as internal standards. For detection, positive ionization electrospray tandem mass spectrometry was used. Method development including optimisation of the mass transitions and response, mobile phase optimisation and column selection are discussed. The method was validated according to FDA guidelines and the principles of Good Laboratory Practice (GLP). The validated range was 0.5-500 ng/mL for paclitaxel and docetaxel and 2-2000 ng/mL for ritonavir. For quantification, quadratic calibration curves were used (r(2)>0.99). The total runtime of the method is 9 min and the assay combines analytes with differences in ionisation and desired concentration range. Inter-assay accuracy and precision were tested at four concentration levels and were within 10% and less than 10%, respectively, for all analytes. Carry-over was less than 6% and endogenous interferences or interferences between analytes and internal standards were less than 20% of the response at the lower limit of quantification level. The matrix factor and recovery were determined at low, mid and high concentration levels. The matrix factor was around 1 for all analytes and total recovery between 77.5 and 104%. Stability was investigated in stock solutions, human plasma, dry extracts, final extracts and during 3 freeze/thaw cycles. The described method was successfully applied in clinical studies with oral administration of docetaxel or paclitaxel in combination with ritonavir.  相似文献   

9.
ZT-1 is a novel acetylcholinesterase (AChE) inhibitor. It is rapidly transformed to Huperzine A (Hup A) in vitro. A simple and rapid HPLC-UV method for the simultaneous determination of ZT-1 and its metabolite Hup A in plasma is described. The chromatographic separations were achieved on a C(18) ODS column (250 mm x 4.6 mm ID) using methanol-1 mmol/L ammonium acetate (70:30,v/v) as mobile phase. The flow rate was 0.7 mL/min, the detection wavelength was 313 nm and the column temperature was kept at 35 degrees C. Plasma samples were prepared as rapidly as possible and extracted immediately with 5 mL of chloroform:iso-propyl alcohol mixture (v/v, 9:1).The retention times of ZT-1 and Huperzine A (Hup A) were 18.7 and 14.4 min, respectively. The mean absolute recoveries of two analytes were >90%. Quantification limits were all 0.02 nmol/mL for ZT-1 and Hup A. This analytical method was reliable and convenient procedure that meets the criteria for the pharmacokinetic evaluation of ZT-1 on experimental animals.  相似文献   

10.
To study the pharmacokinetics of Chan Su, a sensitive and selective method was developed and validated for the determination of five main bufadienolides (cinobufagin, resibufogenin, bufalin, bufotalin and arenobufagin) in rat plasma. The analytes were extracted by liquid-liquid extraction with ethyl acetate after internal standard (IS, caudatin) spiked. The separation was performed by a ZORBAX SB-C18 column (3.5 microm, 2.1 mmx100 mm) and a C18 guard column (5 microm, 4.0 mmx2.0 mm) with an isocratic mobile phase consisted of acetonitrile-water-formic acid (50:50:0.05, v/v/v) at a flow rate of 0.3 mL/min. The Agilent G6410A triple quadrupole LC/MS system was operated under the multiple reaction monitoring mode (MRM) using the electrospray ionization technique in positive mode. The nominal retention times for cinobufagin, resibufogenin, bufalin, bufotalin, arenobufagin and caudatin were 3.07, 3.55, 2.30, 1.62, 1.22 and 3.43 min, respectively. All analytes showed good linearity in a wide concentration range (r>0.995) and their lower limits of quantification (LLOQ) were all 1.0 ng/mL. The method was linear for all analytes with correlation coefficients>0.995 for all analytes. The average extract recoveries of the five analytes from rat plasma were all over 85%, the precisions and accuracies determined were all within 15%. This method has been successfully applied to pharmacokinetic study of Chan Su in rats following oral administration.  相似文献   

11.
A simple, accurate and precise high-performance liquid chromatographic method with fluorescence detection was developed and validated for the determination of gemifloxacin (GEM) in rat plasma using furosemide as internal standard (I.S.). Plasma samples were pretreated by direct deproteinization and all samples and standard solutions were chromatographed at 45°C using triethylamine solution (0.5%, v/v, pH 3.0±0.1), methanol and acetonitrile (63:30:7, v/v/v) as the mobile phase. Chromatographic resolution was achieved using a RP-C(18) column (Atlantis, Waters, 150 mm × 4.6 mm, 5 μm) at a flow rate of 1.0 mL min(-1) and an injection volume of 30 μL. The analytes were measured by fluorescence detection with excitation and emission wavelengths of 344 nm and 399 nm, respectively. The retention times for GEM and I.S. were approximately 7.5 and 12.6 min, respectively. The lower limit of quantitation (LLOQ) was 20 ng mL(-1) and the calibration curves were linear over a concentration range of 20-5000 ng mL(-1). The intra- and inter-day precisions, expressed by relative standard deviation (R.S.D.) were lower than 6.24% and 4.49%, respectively. The accuracy ranged from 91.3% to 112% and from 98.8% to 106% for the lower and upper limit of quantitation of the calibration curve, respectively. Ratio of peak area of analyte to I.S. was used for quantification of plasma samples. No interferences from endogenous substances were found. The recovery of GEM and I.S. from plasma was greater than 90%. Drug stability in plasma was shown at room temperature for 4h, after three freeze-thaw cycles for 24h, in freezer at -80°C for 60 days, and in the autosampler after processing for 12h. The utility of the assay was confirmed by the successful analysis of plasma samples from GEM pharmacokinetics studies in the rats after intravenous administration.  相似文献   

12.
The alkaloids from Piper longum L. showed protective effects on Parkinson's disease models in our previous study and piperine and piperlonguminine were the two main constituents in the alkaloids. The present study aimed at developing a rapid, sensitive, and accurate UFLC-ESI-MS/MS method and validating it for the simultaneous determination of piperine and piperlonguminine in rat plasma using terfenadine as the internal standard. The analytes and internal standard (IS) were extracted from rat plasma using a simple protein precipitation by adding methanol/acetonitrile (1:1, v/v). A Phenomenex Gemini 3 u C18 column (20 mm × 2.00 mm, 3 μm) was used to separate the analytes and IS using a gradient mode system with a mobile phase consisting of water with 0.1% formic acid (mobile phase A) and acetonitrile with 0.1% formic acid (mobile phase B) at a flow rate of 0.4 mL/min and an operating column temperature of 25°C. The total analytical run time was 4 min. The detection was performed using the positive ion electrospray ionization (ESI) in multiple reaction monitoring (MRM) mode with transitions at m/z 286.1-201.1 for piperine, m/z 274.0-201.1 for piperlonguminine, and m/z 472.4-436.4 for the IS. The calibration curves were both linear (r>0.995) over a concentration range of 1.0 to 1000 ng/mL; the lower limit of quantification (LLOQ) was 1.0 ng/mL for both piperine and piperlonguminine. The intra-day and inter-day precisions (RSD %) were <12.1%, accuracies ranged from 86.6 to 120%, and recoveries ranged from 90.4 to 108%. The analytes were proven stable in the short-term, long-term, and after three freeze-thaw cycles. The method was successfully applied to pharmacokinetic studies of piperine and piperlonguminine in rats after oral administration of alkaloids from P. longum L.  相似文献   

13.
We developed and validated a quantitative method for simultaneously determining the concentrations of tracheloside and trachelogenin in rat plasma. Plasma samples were prepared by liquid-liquid extraction with ethyl acetate. Isocratic chromatographic separation was performed on a reversed-phase Diamonsil C(18) column (4.6×200 mm, 5 μm). The mobile phase consisted of methanol and 10mM aqueous ammonium formate (80:20, v/v). Analyte detection was achieved by positive electrospray ionization (ESI) tandem mass spectrometry. Calibration was performed by internal standardization with glipizide, and regression curves ranging from 0.625 to 625 ng/mL were constructed for both the analytes. The intra- and inter-day precision values were below 8%, and accuracy ranged from -5.33% to 2.53% in all quality control samples. In this study, the validated method was successfully applied to determine the pharmacokinetic profile of tracheloside and trachelogenin in rat plasma after oral and intravenous administration of trachelospermi total lignans.  相似文献   

14.
The method of high-performance liquid chromatography (HPLC) with UV-vis detection was used and validated for the simultaneous determination of six flavonoids (puerarin, rutin, morin, luteolin, quercetin, kaempferol) and troxerutin in rat urine and chicken plasma. Chromatographic separation was performed using a VP-ODS column (150 mm x 4.6 mm, 5.0 microm) maintained at 35.0 degrees C. The mobile phase was a mixture of water, methanol and acetic acid (57:43:1, v/v/v, pH 3.0) at the flow rate of 0.8 mL/min. Six flavonoids and troxerutin were analyzed simultaneously with good separation. On optimum conditions, calibration curves were found to be linear with the ranges of 0.10-70.00 microg/mL (puerarin, rutin, morin, luteolin, quercetin, kaempferol) and 0.50-350.00 microg/mL (troxerutin). The detection limits were 0.010-0.050 microg/mL. The method was validated for accuracy and precision, and it was successfully applied to determine drug concentrations in rat urine and chicken plasma samples from rat and chicken that had been orally administered with six flavonoids and troxerutin.  相似文献   

15.
Apigenin is a flavone and is being developed for treatment of cardiovascular disease. A sensitive and accurate quantitative detection method using liquid chromatography coupled with tandem mass spectrometry (LC/MS/MS) for the measurement of apigenin and luteolin levels in rat plasma is described. Analytes were separated on a separation by a Luna C(18) (5 microm, 100 mm x 2.0 mm) column with acetonitrile:methanol:water (35:40:60, v/v/v) as a mobile phase. The eluted compounds were detected by tandem mass spectrometry. Good linearity (R(2)>0.9997) was observed for both analytes over the range of 2.5-5000 ng/mL in 0.1mL of rat plasma. The overall accuracy of this method was 93-105% for apigenin and 95-112% for luteolin in rat plasma. Intra-assay and inter-assay variabilities were less than 11% in plasma. The lowest quantitation limit for both apigenin and luteolin was 2.5 ng/mL in 0.1 mL of rat plasma. Practical utility of this new LC/MS/MS method was demonstrated in a pilot pharmacokinetic study in rats following intravenous administration of apigenin. Metabolism of apigenin to luteolin in vivo was established.  相似文献   

16.
Glycyrrhizin (GLY) which has been widely used in traditional Chinese medicinal preparation possesses various pharmacological effects. In order to investigate the pharmacokinetic behavior of GLY in human after oral administration of GLY or licorice root, a liquid chromatography/tandem mass spectrometry (LC-MS/MS) method was developed and validated for the simultaneous determination of GLY and its major metabolite glycyrrhetic acid (GA) in human plasma. The method involved a solid phase extraction of GLY, GA, and alpha-hederin, the internal standard (IS), from plasma with Waters Oasis MCX solid phase extraction (SPE) cartridges (30 mg) and a detection using a Micromass Quattro LC liquid chromatography/tandem mass spectrometry system with electrospray ionization source in positive ion mode. Separation of the analytes was achieved within 5min on a SepaxHP CN analytical column with a mobile phase of acetonitrile:water (50:50, v:v) containing 0.1% formic acid and 5mM ammonium acetate. Multiple reaction monitoring (MRM) was utilized for the detection monitoring 823--> 453 for GLY, 471--> 177 for GA and 752--> 456 for IS. The LC-MS/MS method was validated for specificity, sensitivity, accuracy, precision, and calibration function. The assay had a calibration range from 10 to 10,000 ng/mL and a lower limit of quantification of 10 ng/mL for both GLY and GA when 0.2 mL plasma was used for extraction. The percent coefficient of variation for accuracy and precision (inter-run and intra-run) for this method was less than 11.0% with a %Nominal ranging from 87.6 to 106.4% for GLY and 93.7 to 107.8% for GA. Stability of the analytes over sample processing (freeze/thaw, bench-top and long-term storage) and in the extracted samples was also tested and established.  相似文献   

17.
A rapid and sensitive method using liquid chromatography-tandem mass spectroscopy (LC-MS/MS) was developed and validated for simultaneous quantitative determination of valproic acid and three major metabolites (3-OH-valproic acid, 4-ene-valproic acid and 5-OH-valproic acid) in human plasma. The analytes and internal standard were isolated from 200 μL samples by solid phase extraction using a ZORBAX SB-C? column (3.5 μm, 2.1×100 mm) with an isocratic mobile phase consisting of methanol-10mM ammonium acetate (80:20, v/v) containing 0.1% formic acid at a flow rate of 0.3 mL/min. The method had a chromatographic total run time of 2.0 min. The lower limit of quantification of valproic acid, 3-OH-valproic acid, 4-ene-valproic acid and 5-OH-valproic acid of the method was 2030, 51.5, 50.15 and 51.25 ng/mL, respectively. The method was linear for valproic acid and the three metabolites with correlation coefficients >0.995 for all analytes. The intra-day and inter-day accuracy and precision of the assay were less than 15.0%. This analytical method was successfully used to assay plasma concentrations of valproic acid and the three metabolites in human plasma from epileptic patients.  相似文献   

18.
A rapid, simple and sensitive HPLC–ESI–MS/MS method was developed for the simultaneous determination of capsaicin and dihydrocapsaicin in rat plasma. Plasma samples containing capsaicin, dihydrocapsaicin and phenacetin (internal standard) were prepared based on a simple protein precipitation by the addition of two volumes of acetonitrile. The analytes and internal standard were separated on a Zorbax SB-C18 column (3.5 μm, 2.1 mm × 100 mm) with mobile phase of acetonitrile/water (55:45, v/v) containing 0.1% formic acid (v/v) at a flow rate of 0.2 mL/min with an operating temperature of 25 °C. Quantification was performed on a triple quadrupole mass spectrometer equipped with electrospray ionization (ESI) source by selected reaction monitoring (SRM) of the transitions at m/z 306–137 for capsaicin, m/z 308–137 for dihydrocapsaicin and m/z 180–110 for the IS. Linear detection responses were obtained for capsaicin and dihydrocapsaicin ranging from 1 to 500 ng/mL and the lower limits of quantitation (LLOQs) for the two compounds were 1 ng/mL. The intra- and inter-day precisions (R.S.D.%) were within 9.79% for the two analytes, while the deviations of assay accuracies were within ±10.63%. The average recoveries of the analytes were greater than 89.88%. The analytes were proved to be stable during all sample storage, preparation and analytic procedures. The method was successfully applied to the pharmacokinetic studies of capsaicin and dihydrocapsaicin in rats after subcutaneous administration of capsaicin (natural, containing 65% capsaicin and 35% dihydrocapsaicin).  相似文献   

19.
A rapid, sensitive and specific method was developed and validated using LC/MS/MS for determination of sunitinib in human plasma. Sample preparation involved a liquid-liquid extraction by the addition of 0.2mL of plasma with 4.0mL tert-butyl-methyl-ether extraction solution containing 25ng/mL of the internal standard clozapine. Separation of compounds was achieved on a C18 (50mmx2.1mm i.d., 3.5microm) analytical column using a mobile phase consisting of acetonitrile/H20 (65:35, v/v) containing 0.1% formic acid and isocratic flow at 0.150mL/min for 3min. The analytes were monitored by tandem-mass spectrometry with electrospray positive ionization. Linear calibration curves in human plasma were generated over the range of 0.2-500ng/mL with values for the coefficient of determination of >0.9950. Within- and between day precision and accuracy were < or =10%. The method was applied to the quantitation of sunitinib in plasma samples from a patient receiving daily oral therapy with sunitinib.  相似文献   

20.
A novel isocratic reversed-phase high performance liquid-chromatography/ultraviolet detection method for simultaneous determination of cefdinir and cefixime in human plasma was developed and validated after optimization of various chromatographic conditions and other experimental parameters. Sample preparation based on a simple extraction procedure consisting of deproteination and extraction with 3 parts of 6% trichloroacetic acid aqueous solution followed by volume make up with the aqueous component of the mobile phase obtained best recoveries of the two analytes. Samples were separated on a Supelco Discovery HS C(18) (150 mm × 4.6 mm, 5 μm) analytical column protected by a Perkin Elmer C(18) (30 mm × 4.6 mm, 10 μm) guard cartridge. The mobile phase, methanol/acetonitrile (50/50, v/v):0.05% trifluoroacetic acid (19:81, v/v), operated at 50°C column oven temperature was pumped at a flow rate of 2.0 mL min(-1) and the column eluents were monitored at a wavelength of 285 nm. When Sample was injected into the Perkin Elmer high performance liquid-chromatography system through Rheodyne manual (or auto-sampler) injector equipped with 20 μL loop, separation was achieved within 4 min. The present method demonstrated acceptable values for selectivity, linearity within the expected concentration range (0.004-5.0 μg mL(-1); r(2)>0.999 for both analytes), recovery (>95% for cefdinir and >96% for cefixime), precision (%RSD<2.0 for cefdinir and <2.2 for cefixime), sensitivity (limit of detection: 1 ng mL(-1) and lower limit of quantification: 4 ng mL(-1) for both analytes), stability of solutions, and robustness. The method was efficiently applied to a pharmacokinetic study in healthy volunteers.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号