共查询到20条相似文献,搜索用时 15 毫秒
1.
Mechanical properties of the rabbit patellar tendon. 总被引:4,自引:0,他引:4
N Yamamoto K Hayashi H Kuriyama K Ohno K Yasuda K Kaneda 《Journal of biomechanical engineering》1992,114(3):332-337
The mechanical and structural properties of the patellar tendon fascicle-bone units of rabbit knees were determined by tensile tests, particularly focusing on their local differences. There were no significant differences in the strains measured by a video dimension analyzer among the proximal, middle, and distal regions of the central portion of tendon. The mechanical properties of the medial portion agreed well with those of the central portion. However, significant differences were observed in the tensile strength between the lateral and the other two portions: the tensile strength of the lateral portion was about 16 percent larger than those in the other portions. 相似文献
2.
Matthew F. Koff Sarah L. PownderParina H. Shah Lim Wei YangHollis G. Potter 《Journal of biomechanics》2014
Tendinopathy affects individuals who perform repetitive joint motion. Magnetic resonance imaging (MRI) is frequently used to qualitatively assess tendon health, but quantitative evaluation of inherent MRI properties of loaded tendon has been limited. This study evaluated the effect of cyclic loading on T2? values of fresh and frozen rabbit patellar tendons using ultra short echo (UTE) MRI. Eight fresh and 8 frozen rabbit lower extremities had MR scans acquired for tendon T2? evaluation. The tendons were then manually cyclically loaded for 100 cycles to 45 N at approximately 1 Hz. The MR scanning was repeated to reassess the T2? values. Analyses were performed to detect differences of tendon T2? values between fresh and frozen samples prior to and after loading, and to detect changes of tendon T2? values between the unloaded and loaded configurations. No difference of T2? was found between the fresh and frozen samples prior to or after loading, p=0.8 and p =0.1, respectively. The tendons had significantly shorter T2? values, p =0.023, and reduced T2? variability, p =0.04, after cyclic loading. Histologic evaluation confirmed no induced tendon damage from loading. Shorter T2?, from stronger spin–spin interactions, may be attributed to greater tissue organization from uncrimping of collagen fibrils and lateral contraction of the tendon during loading. Cyclic tensile loading of tissue reduces patellar tendon T2? values and may provide a quantitative metric to assess tissue organization. 相似文献
3.
Effects of cyclic stress on the mechanical properties of cultured collagen fascicles from the rabbit patellar tendon 总被引:1,自引:0,他引:1
Effects of cyclic stress on the mechanical properties of collagen fascicles were studied by in vitro tissue culture experiments. Collagen fascicles (approximately 300 microns in diameter) obtained from the rabbit patellar tendon were applied cyclic load at 4 Hz for one hour per day during culture period for one or two weeks, and then their mechanical properties were determined using a micro-tensile tester. There was a statistically significant correlation between tensile strength and applied peak stress in the range of 0 to 5 MPa, and the relation was expressed by a quadratic function. The maximum strength (19.4 MPa) was obtained at the applied peak stress of 1.8 MPa. The tensile strength of fascicles were within a range of control values, if they were cultured under peak stresses between 1.1 and 2.6 MPa. Similar results were also observed in the tangent modulus, which was maintained at control level under applied peak stresses between 0.9 and 2.8 MPa. The stress of 0.9 to 1.1 MPa is equivalent to approximately 40% of the in vivo peak stress which is developed in the intact rabbit patellar tendon by running, whereas that of 2.6 to 2.8 MPa corresponds to approximately 120% of the in vivo peak stress. Therefore, the fascicles cultured under applied peak stresses of lower than 40% and higher than 120% of the in vivo peak stress do not keep the original strength and modulus. These results indicate that the mechanical properties of cultured collagen fascicles strongly depend upon the magnitude of the stress applied during culture, which are similar to our previous results observed in stress-shielded and overstressed patellar tendons in vivo. 相似文献
4.
Tensile and viscoelastic properties of collagen fascicles of approximately 300 microns in diameter, which were obtained from rabbit patellar tendons, were studied using a newly designed micro-tensile tester. Their cross-sectional areas were determined with a video dimension analyzer combined with a CCD camera and a low magnification microscope. There were no statistically significant differences in tensile properties among the fascicles obtained from six medial-to-lateral locations of the patellar tendon. Tangent modulus, tensile strength, and strain at failure of the fascicles determined at about 1.5 percent/s strain rate were 216 +/- 68 MPa, 17.2 +/- 4.1 MPa, and 10.9 +/- 1.6 percent (mean +/- S.D.), respectively. These properties were much different from those of bulk patellar tendons; for example, the tensile strength and strain at failure of these fascicles were 42 percent and 179 percent of those of bulk tendons, respectively. Tangent modulus and tensile strength of collagen fascicles determined at 1 percent/s strain rate were 35 percent larger than those at 0.01 percent/s. The strain at failure was independent of strain rate. Relaxation tests showed that the reduction of stress was approximately 25 percent at 300 seconds. These stress relaxation behavior and strain rate effects of collagen fascicles differed greatly from those of bulk tendons. The differences in tensile and viscoelastic properties between fascicles and bulk tendons may be attributable to ground substances, mechanical interaction between fascicles, and the difference of crimp structure of collagen fibrils. 相似文献
5.
The effect of aging on soft tissue repair is poorly understood. We examined collagen fibril diameter in repairing patellar tendons from young adult and aging rabbits. We hypothesized that repairing tendons from older (geriatric) rabbits would have similar diameter fibrils compared with the younger (young adult) rabbits. Full-length, full-thickness, central-third (2.5 to 3 mm) patellar tendon injuries were made by cutting out the center of the tendon in twelve 1-y-old and thirteen 4- to 5.5 (average, 4.25)-y-old female New Zealand White rabbits. The contralateral tendon served as an unoperated control. The rabbits were euthanized at 6, 12, and 26 wk after surgery. The collagen fibril diameter was examined by electron microscopy at the patellar end, middle, and tibial end of the patellar tendon. There was no significant decline in collagen fibril diameter at any location in the aging rabbit healing patellar tendons compared with those of the 1-y-old rabbits. This study found that collagen fibril diameter was not altered with increasing age in the healing rabbit patellar tendon. 相似文献
6.
John Clemmer Jun Liao Debbie Davis Mark F. Horstemeyer Lakiesha N. Williams 《Journal of biomechanics》2010,43(14):2785-2791
The ultrastructural mechanism for strain rate sensitivity of collagenous tissue has not been well studied at the collagen fibril level. Our objective is to reveal the mechanistic contribution of tendon’s key structural component to strain rate sensitivity. We have investigated the structure of the collagen fibril undergoing tension at different strain rates. Tendon fascicles were pulled and fixed within the linear region (12% local tissue strain) at multiple strain rates. Although samples were pulled to the same percent elongation, the fibrils were noticed to elongate differently, increasing with strain rate. For the 0.1, 10, and 70%/s strain rates, there were 1.84±3.6%, 5.5±1.9%, and 7.03±2.2% elongations (mean±S.D.), respectively. We concluded that the collagen fibrils underwent significantly greater recruitment (fibril strain relative to global tissue strain) at higher strain rates. A better understanding of tendon mechanisms at lower hierarchical levels would help establish a basis for future development of constitutive models and assist in tissue replacement design. 相似文献
7.
Chromophore reorientations during the bacteriorhodopsin photocycle in the purple membrane of Halobacterium salinarium have been detected by time-resolved linear dichroism measurements of the optical anisotropy over the pH range from 4 to 10 and at ionic strengths from 10 mM to 1 M. The results show that reorientations in the L and M states of bacteriorhodopsin are pH dependent, reaching their largest amplitude when the membrane is at pH 6-8. Reorientations on the millisecond time scale of unexcited spectator proteins in the native purple membrane also depend on pH, consistent with the suggestion that spectator reorientations are triggered by reorientation of the photoexcited protein. The results imply that a group with a PK(a) of 5 to 6 enables reorientations, and that the deprotonation of a site at pH values above 9 restricts reorientational motion. This suggests that reorientations in M may be correlated with proton release. 相似文献
8.
Proliferation and collagen production of human patellar tendon fibroblasts in response to cyclic uniaxial stretching in serum-free conditions 总被引:12,自引:0,他引:12
We studied the effect of cyclic mechanical stretching on the proliferation and collagen mRNA expression and protein production of human patellar tendon fibroblasts under serum-free conditions. The role of transforming growth factor-beta1 (TGF-beta1) in collagen production by cyclically stretched tendon fibroblasts was also investigated. The tendon fibroblasts were grown in microgrooved silicone dishes, where the cells were highly elongated and aligned with the microgrooves. Cyclic uniaxial stretching with constant frequency and duration (0.5 Hz, 4 h) but varying magnitude of stretch (no stretch, 4%, and 8%) was applied to the silicone dishes. Following the period of stretching, the cells were rested for 20 h in stretching-conditioned medium to allow for cell proliferation. In separate experiments, the cells were stretched for 4h and then rested for another 4 h. Samples of the medium, total cellular RNA and protein were used for analysis of collagen and TGF-beta1 gene expression and production. It was found that there was a slight increase in fibroblast proliferation at 4% and 8% stretch, compared to that of non-stretched fibroblasts, where at 8% stretch the increase was significant. It was also found that the gene expression and protein production of collagen type I and TGF-beta1 increased in a stretching-magnitude-dependent manner. And, levels of collagen type III were not changed, despite gene expression levels of the protein being slightly increased. Furthermore, the exogenous addition of anti-TGF-beta1 antibody eliminated the increase in collagen type I production under cyclic uniaxial stretching conditions. The results suggest that mechanical stretching can modulate proliferation of human tendon fibroblasts in the absence of serum and increase the cellular production of collagen type I, which is at least in part mediated by TGF-beta1. 相似文献
9.
N Yamamoto K Hayashi F Hayashi K Yasuda K Kaneda 《Journal of biomechanical engineering》1999,121(3):323-329
Effects of the overstressing induced by the harvest of grafts from the patellar tendon on the mechanical properties and morphometry of remaining tendon were studied using a rabbit model. The width of the patellar tendon was reduced by one-fourth or one-half equally removing the medial and lateral portions; by this surgery, the cross-sectional area was decreased by 25 or 50 percent from the original area. After all the rabbits were allowed unrestricted activities in cages for 3 to 12 weeks, their patellar tendons were harvested for mechanical and histological studies. The one-fourth removal induced no significant changes in the mechanical properties, but significantly increased the cross-sectional area. In the case of one-half removal, tensile strength and tangent modulus did not change in some tendons, although the cross-sectional area increased significantly. In the other central half tendons, mechanical strength decreased markedly, while the cross-sectional area increased; hypercellular areas and breakage of collagen bundles were observed in these tendons. These results indicate that the patellar tendon has an ability of functionally adapting to overstressing by changing the cross-sectional area, while keeping the mechanical properties unchanged, if the extent of overstressing is less than 30 percent. 相似文献
10.
Thomas D. O’Brien Neil D. Reeves Vasilios Baltzopoulos David A. Jones Constantinos N. Maganaris 《Journal of biomechanics》2010,43(6):1190-1195
It is not currently known how the mechanical properties of human tendons change with maturation in the two sexes. To address this, the stiffness and Young's modulus of the patellar tendon were measured in men, women, boys and girls (each group, n=10). Patellar tendon force (Fpt) was calculated from the measured joint moment during a ramped voluntary isometric knee extension contraction, the antagonist knee extensor muscle co-activation quantified from its electromyographical activity, and the patellar tendon moment arm measured from magnetic resonance images. Tendon elongation was imaged using the sagittal-plane ultrasound scans throughout the contraction. Tendon cross-sectional area was measured at rest from ultrasound scans in the transverse plane. Maximal Fpt and tendon elongation were (mean±SE) 5453±307 N and 5±0.5 mm for men, 3877±307 N and 4.9±0.6 mm for women, 2017±170 N and 6.2±0.5 mm for boys and 2169±182 N and 5.9±0.7 mm for girls. In all groups, tendon stiffness and Young's modulus were examined at the level that corresponded to the maximal 30% of the weakest participant's Fpt and stress, respectively; these were 925–1321 N and 11.5–16.5 MPa, respectively. Stiffness was 94% greater in men than boys and 84% greater in women than girls (p<0.01), with no differences between men and women, or boys and girls (men 1076±87 N/mm; women 1030±139 N/mm; boys 555±71 N/mm and girls 561.5±57.4 N/mm). Young's modulus was 99% greater in men than boys (p<0.01), and 66% greater in women than girls (p<0.05). There were no differences in modulus between men and women, or boys and girls (men 597±49 MPa; women 549±70 MPa; boys 255±42 MPa and girls 302±33 MPa). These findings indicate that the mechanical stiffness of tendon increases with maturation due to an increased Young's modulus and, in females due to a greater increase in tendon cross-sectional area than tendon length. 相似文献
11.
Habitual loading results in tendon hypertrophy and increased stiffness of the human patellar tendon.
C Couppé M Kongsgaard P Aagaard P Hansen J Bojsen-Moller M Kjaer S P Magnusson 《Journal of applied physiology》2008,105(3):805-810
The purpose of this study was to examine patellar tendon (PT) size and mechanical properties in subjects with a side-to-side strength difference of >/=15% due to sport-induced loading. Seven elite fencers and badminton players were included. Cross-sectional area (CSA) of the PT obtained from MRI and ultrasonography-based measurement of tibial and patellar movement together with PT force during isometric contractions were used to estimate mechanical properties of the PT bilaterally. We found that distal tendon and PT, but not mid-tendon, CSA were greater on the lead extremity compared with the nonlead extremity (distal: 139 +/- 11 vs. 116 +/- 7 mm(2); mid-tendon: 85 +/- 5 vs. 77 +/- 3 mm(2); proximal: 106 +/- 7 vs. 83 +/- 4 mm(2); P < 0.05). Distal tendon CSA was greater than proximal and mid-tendon CSA on both the lead and nonlead extremity (P < 0.05). For a given common force, stress was lower on the lead extremity (52.9 +/- 4.8 MPa) compared with the nonlead extremity (66.0 +/- 8.0 MPa; P < 0.05). PT stiffness was also higher in the lead extremity (4,766 +/- 716 N/mm) compared with the nonlead extremity (3,494 +/- 446 N/mm) (P < 0.05), whereas the modulus did not differ (lead 2.27 +/- 0.27 GPa vs. nonlead 2.16 +/- 0.28 GPa) at a common force. These data show that a habitual loading is associated with a significant increase in PT size and mechanical properties. 相似文献
12.
In-vitro tissue culture experiments were performed to study the effects of static stress on the mechanical properties of collagen fascicles obtained from the rabbit patellar tendon. After collagen fascicles having the diameter of approximately 300 microm were cultured for 1 and 2 wk under static stress between 0 and 3 MPa, their mechanical properties and crimp morphology were determined using a micro-tensile tester and a light microscope, respectively. The tensile strength and tangent modulus of the fascicles were significantly decreased by culture under no load compared to control fascicles. A statistically significant correlation, which was described by a quadratic curve, was observed between applied stress and tensile strength. The maximum tensile strength (16.7 MPa) was obtained at the applied stress of 1.2 MPa; the strength was within a range of control values. There was a similar correlation between applied stress and tangent modulus, and the modulus was maintained at control level under 1.3 MPa stress. The stress of 1.2 to 1.3 MPa is equivalent to approximately 50 percent of the peak stress developed in the intact rabbit patellar tendon by running. Strain at failure of cultured collagen fascicles was negatively correlated with applied stress, and that at 1.2 to 1.3 MPa stress was almost the same as the control value. Crimp morphology in the fascicles cultured under about 1.2 MPa stress was similar to that in control fascicles. These results indicate that cultured collagen fascicles change the mechanical properties and structure in response to static tensile stress. In addition, their mechanical properties and structure are maintained at control level if the static stress of 50 percent of in-vivo peak stress is applied. 相似文献
13.
Svensson RB Hansen P Hassenkam T Haraldsson BT Aagaard P Kovanen V Krogsgaard M Kjaer M Magnusson SP 《Journal of applied physiology (Bethesda, Md. : 1985)》2012,112(3):419-426
Tendons are strong hierarchical structures, but how tensile forces are transmitted between different levels remains incompletely understood. Collagen fibrils are thought to be primary determinants of whole tendon properties, and therefore we hypothesized that the whole human patellar tendon and its distinct collagen fibrils would display similar mechanical properties. Human patellar tendons (n = 5) were mechanically tested in vivo by ultrasonography. Biopsies were obtained from each tendon, and individual collagen fibrils were dissected and tested mechanically by atomic force microscopy. The Young's modulus was 2.0 ± 0.5 GPa, and the toe region reached 3.3 ± 1.9% strain in whole patellar tendons. Based on dry cross-sectional area, the Young's modulus of isolated collagen fibrils was 2.8 ± 0.3 GPa, and the toe region reached 0.86 ± 0.08% strain. The measured fibril modulus was insufficient to account for the modulus of the tendon in vivo when fibril content in the tendon was accounted for. Thus, our original hypothesis was not supported, although the in vitro fibril modulus corresponded well with reported in vitro tendon values. This correspondence together with the fibril modulus not being greater than that of tendon supports that fibrillar rather than interfibrillar properties govern the subfailure tendon response, making the fibrillar level a meaningful target of intervention. The lower modulus found in vitro suggests a possible adverse effect of removing the tissue from its natural environment. In addition to the primary work comparing the two hierarchical levels, we also verified the existence of viscoelastic behavior in isolated human collagen fibrils. 相似文献
14.
Despite the public health importance of Salmonella infection in pigs, little is known about the associated dynamics of fecal shedding and immunity. In this study, we investigated the transitions of pigs through the states of Salmonella fecal shedding and immune response post-Salmonella inoculation as affected by the challenge dose and serotype. Continuous-time multistate Markov models were developed using published experimental data. The model for shedding had four transient states, of which two were shedding (continuous and intermittent shedding) and two non-shedding (latency and intermittent non-shedding), and one absorbing state representing permanent cessation of shedding. The immune response model had two transient states representing responses below and above the seroconversion level. The effects of two doses [low (0.65×10(6) CFU/pig) and high (0.65×10(9) CFU/pig)] and four serotypes (Salmonella Yoruba, Salmonella Cubana, Salmonella Typhimurium, and Salmonella Derby) on the models' transition intensities were evaluated using a proportional intensities model. Results indicated statistically significant effects of the challenge dose and serotype on the dynamics of shedding and immune response. The time spent in the specific states was also estimated. Continuous shedding was on average 10-26 days longer, while intermittent non-shedding was 2-4 days shorter, in pigs challenged with the high compared to low dose. Interestingly, among pigs challenged with the high dose, the continuous and intermittent shedding states were on average up to 10-17 and 3-4 days longer, respectively, in pigs infected with S. Cubana compared to the other three serotypes. Pigs challenged with the high dose of S. Typhimurium or S. Derby seroconverted on average up to 8-11 days faster compared to the low dose. These findings highlight that Salmonella fecal shedding and immune response following Salmonella challenge are dose- and serotype-dependent and that the detection of specific Salmonella strains and immune responses in pigs are time-sensitive. 相似文献
15.
Francine G Smith Alp Sener Raghmeet Basati Isam Abu-Amarah 《Journal of applied physiology》2004,96(1):131-136
Experiments were carried out in conscious, chronically instrumented lambs (n = 8) and young adult sheep (n = 11) to investigate age-dependent renal responses to hemorrhage. Various parameters of renal function were measured for 1 h before and 1 h after either 10% hemorrhage (experiment 1) or 20% hemorrhage (experiment 2). The two experiments were carried out in random order at intervals of 2-5 days. There were no effects of 10-20% hemorrhage on renal plasma flow in either age group. Blood pressure decreased after 20% but not 10% hemorrhage in both age groups. Glomerular filtration rate and filtration fraction decreased after 20% hemorrhage in both age groups, the decrease being greater in lambs than young adult sheep. In response to 20% hemorrhage, urinary flow rate and urinary Na+ excretion rate decreased by 40 min after hemorrhage in young adult sheep but not lambs and remained decreased for 60 min; urinary chloride excretion rate showed a similar response. In lambs but not young adult sheep, free water clearance increased by 20 min after 20% hemorrhage and remained above control at 60 min. Urinary osmolality decreased at 20 min after 20% hemorrhage in young adult sheep but not lambs, returning to control levels by 40 min. These data provide new information that renal responses to hypotensive hemorrhage appear to be developmentally regulated. 相似文献
16.
Moment arm of the patellar tendon in the human knee 总被引:5,自引:0,他引:5
The moment arm of the knee-extensor mechanism is described by the moment arm of the patellar tendon calculated with respect to the screw axis of the tibia relative to the femur. The moment arm may be found once the line of action of the patellar tendon and the position and orientation of the screw axis are known. In this study, the orientation of the patellar tendon and the position and orientation of the finite screw axis of the tibia relative to the femur were calculated from measurements of the three-dimensional positions of the bones obtained from fresh cadaver specimens. Peak values of the patellar tendon moment arm ranged from 4-6 cm for the six knees tested; the moment arm was maximum near 45 degrees of knee flexion. The moment arm of the patellar tendon was nearly equal to the shortest (perpendicular) distance between the line of action of the patellar tendon and the axis of rotation of the knee at all flexion angles, except near full extension. Near full extension, the angle between the patellar tendon and the screw axis was significantly less than 90 degrees, and the magnitude of the moment arm was then less than the perpendicular distance between these two lines. The patellar tendon moment arm remained roughly constant across individuals when normalized by femoral condyle width, suggesting that anatomical differences play a large role in determining the moment arm of the extensor mechanism. 相似文献
17.
D L Butler M Y Sheh D C Stouffer V A Samaranayake M S Levy 《Journal of biomechanical engineering》1990,112(1):38-45
Local surface strains in bone-fascicle-bone subunits from human patellar tendon and anterior and posterior cruciate ligaments were measured between markers using low-speed photography during low rate subfailure testing. A simple stress-strain relationship of the power form was found to describe the bone-to-bone responses up to four percent strain for all three tissue types examined. The regional material behavior were best fit using an inverted strain-stress relationship, however. The power model, fitted to the experimental data, conformed to the expected stress-strain relationship better than either the quadratic or cubic models. With few exceptions, for a given stress, the strains near the proximal and distal bone ends were not significantly different from each other, but were significantly higher than the strains in the tissue midregions. Local strain patterns generally varied among subunits from the same tissue. 相似文献
18.
19.
20.
Belvedere C Ensini A Feliciangeli A Cenni F D'Angeli V Giannini S Leardini A 《Journal of biomechanics》2012,45(11):1886-1892
Patterns of fibre elongation and orientation for the cruciate and collateral ligaments of the human knee joint and for the patellar tendon have not yet been established in three-dimensions. These patterns are essential for understanding thoroughly the contribution of these soft tissues to joint function and of value in surgical treatments for a more conscious assessment of the knee status. Measurements from 10 normal cadaver knees are here reported using an accurate surgical navigation system and consistent anatomical references, over a large flexion arc, and according to current recommended conventions. The contours of relevant sub-bundles were digitised over the corresponding origins and insertions on the bones. Representative fibres were calculated as the straight line segments joining the centroids of these attachment areas. The most isometric fibre was also taken as that whose attachment points were at the minimum change in length over the flexion arc. Changes in length and orientation of these fibres were reported versus the flexion angle. A good general repeatability of intra- and inter-specimens was found. Isometric fibres were found in the locations reported in the literature. During knee flexion, ligament sub-bundles slacken in the anterior cruciate ligament, and in the medial and lateral collateral ligaments, whereas they tighten in the posterior cruciate ligament. In each cruciate ligament the two compounding sub-bundles have different extents for the change in fibre length, and also bend differently from each other on both tibial planes. In the collateral ligaments and patellar tendon all fibres bend posteriorly. Patellar tendon underwent complex changes in length and orientation, on both the tibial sagittal and frontal planes. For the first time thorough and consistent patterns of geometrical changes are provided for the main knee ligaments and tendons after careful fibre mapping. 相似文献