1.

Background

Diagnosis of leptospirosis by the microscopic agglutination test (MAT) or by culture is confined to specialized laboratories. Although ELISA techniques are more common, they still require laboratory facilities. Rapid Diagnostic Tests (RDTs) can be used for easy point-of-care diagnosis. This study aims to evaluate the diagnostic performance of the RDTs LeptoTek Dri Dot, LeptoTek Lateral Flow, and Leptocheck-WB, prospectively.

Methodology

During 2001 to 2012, one or two of the RDTs at the same time have been applied prior to routine diagnostics (MAT, ELISA and culture) on serum specimens from participants sent in for leptospirosis diagnosis. The case definition was based on MAT, ELISA and culture results. Participants not fulfilling the case definition were considered not to have leptospirosis. The diagnostic accuracy was determined based on the 1st submitted sample and paired samples, either in an overall analysis or stratified according to days post onset of illness.

Results

The overall sensitivity and specificity for the LeptoTek Dri Dot was 75% respectively 96%, for the LeptoTek Lateral Flow 78% respectively 95%, and for the Leptocheck-WB 78% respectively 98%. Based on the 1st submitted sample the sensitivity was low (51% for LeptoTek Dri Dot, 69% for LeptoTek Lateral Flow, and 55% for Leptocheck-WB), but substantially increased when the results of paired samples were combined, although accompanied by a lower specificity (82% respectively 91% for LeptoTek Dri Dot, 86% respectively 84% for LeptoTek Lateral Flow, and 80% respectively 93% for Leptocheck-WB).

Conclusions

All three tests present antibody tests contributing to the diagnosis of leptospirosis, thus supporting clinical suspicion and contributing to awareness. Since the overall sensitivity of the tested RDTs did not exceed 80%, one should be cautious to rely only on an RDT result, and confirmation by reference tests is strongly recommended.  相似文献   

2.

Background

Malaria presents a diagnostic challenge in areas where both Plasmodium falciparum and P.vivax are co-endemic. Bivalent Rapid Diagnostic tests (RDTs) showed promise as diagnostic tools for P.falciparum and P.vivax. To assist national malaria control programme in the selection of RDTs, commercially available seven malaria RDTs were evaluated in terms of their performance with special reference to heat stability.

Methodology/Principal Findings

This study was undertaken in four forested districts of central India (July, 2011– March, 2012). All RDTs were tested simultaneously in field along with microscopy as gold standard. These RDTs were stored in their original packing at 25°C before transport to the field or they were stored at 35°C and 45°C upto 100 days for testing the performance of RDTs at high temperature. In all 2841 patients with fever were screened for malaria of which 26% were positive for P.falciparum, and 17% for P.vivax. The highest sensitivity of any RDT for P.falciparum was 98% (95% CI; 95.9–98.8) and lowest sensitivity was 76% (95% CI; 71.7–79.6). For P.vivax highest and lowest sensitivity for any RDT was 80% (95% CI; 94.9 - 83.9) and 20% (95% CI; 15.6–24.5) respectively. Heat stability experiments showed that most RDTs for P.falciparum showed high sensitivity at 45°C upto 90 days. While for P.vivax only two RDTs maintained good sensitivity upto day 90 when compared with RDTs kept at room temperature. Agreement between observers was excellent for positive and negative readings for both P.falciparum and P.vivax (Kappa >0.6–0.9).

Conclusion

This is first field evaluation of RDTs regarding their temperature stability. Although RDTs are useful as diagnostic tool for P.falciparum and P.vivax even at high temperature, the quality of RDTs should be regulated and monitored more closely.  相似文献   

3.
4.
BackgroundOne of the key barriers preventing rapid diagnosis of leptospirosis is the lack of available sensitive point-of-care testing. This study aimed to develop and validate a clustered regularly-interspaced short palindromic repeat (CRISPR)/CRISPR-associated protein 12a (CRISPR/Cas12a) platform combined with isothermal amplification to detect leptospires from extracted patient DNA samples.Methodology/Principal findingsA Recombinase Polymerase Amplification (RPA)-CRISPR/Cas12a-fluorescence assay was designed to detect the lipL32 gene of pathogenic Leptospira spp. The assays demonstrated a limit of detection (LOD) of 100 cells/mL, with no cross-reactivity against several other acute febrile illnesses. The clinical performance of the assay was validated with DNA extracted from 110 clinical specimens and then compared to results from qPCR detection of Leptospira spp. The RPA-CRISPR/Cas12a assay showed 85.2% sensitivity, 100% specificity, and 92.7% accuracy. The sensitivity increased on days 4–6 after the fever onset and decreased after day 7. The specificity was consistent for several days after the onset of fever. The overall performance of the RPA-CRISPR/Cas12a platform was better than the commercial rapid diagnostic test (RDT). We also developed a lateral flow detection assay (LFDA) combined with RPA-CRISPR/Cas12a to make the test more accessible and easier to interpret. The combined LFDA showed a similar LOD of 100 cells/mL and could correctly distinguish between known positive and negative clinical samples in a pilot study.Conclusions/SignificanceThe RPA-CRISPR/Cas12 targeting the lipL32 gene demonstrated acceptable sensitivity and excellent specificity for detection of leptospires. This assay might be an appropriate test for acute leptospirosis screening in limited-resource settings.  相似文献   

5.
BackgroundCholera, an acute diarrheal disease is a major public health problem in many developing countries. Several rapid diagnostic tests (RDT) are available for the detection of cholera, but their efficacies are not compared in an endemic setting. In this study, we have compared the specificity and sensitivity of three RDT kits for the detection of Vibrio cholerae O1 and compared their efficiency with culture and polymerase chain reaction (PCR) methods.MethodsFive hundred six diarrheal stool samples collected from patients from two different hospitals in Kolkata, India were tested using SD Bioline Cholera, SMART-II Cholera O1 and Crystal-VC RDT kits. All the stool samples were screened for the presence of V. cholerae by direct and enrichment culture methods. Stool DNA-based PCR assay was made to target the cholera toxin (ctxAB) and O1 somatic antigen (rfb) encoding genes. Statistical evaluation of the RDTs has been made using STATA software with stool culture and PCR results as the gold standards. The Bayesian latent class model (LCM) was used to evaluate the diagnostic tests in the absence of the gold standard.ResultsInvolving culture technique as gold standard, the sensitivity and specificity of the cholera RDT kits in the direct testing of stools was highest with SAMRT-II (86.1%) and SD-Cholera (94.4%), respectively. The DNA based PCR assays gave very high sensitivity (98.4%) but the specificity was comparatively low (75.3%). After enrichment, the high sensitivity and specificity was detected with SAMRT-II (78.8%) and SD-Cholera (99.1%), respectively. Considering PCR as the gold standard, the sensitivity and specificity of the RDTs remained between 52.3–58.2% and 92.3–96.8%, respectively. In the LCM, the sensitivity of direct and enrichment testing was high in SAMRT-II (88% and 92%, respectively), but the specificity was high in SD cholera for both the methods (97% and 100%, respectively). The sensitivity/specificity of RDTs and direct culture have also been analyzed considering the age, gender and diarrheal disease severity of the patients.ConclusionOverall, the performance of the RDT kits remained almost similar in terms of specificity and sensitivity. Performance of PCR was superior to the antibody-based RDTs. The RTDs are very useful in identifying cholera cases during outbreak/epidemic situations and for making them as a point-of-care (POC) testing tool needs more improvement.  相似文献   

6.
BackgroundCharacterising dengue virus (DENV) infection history at the point of care is challenging as it relies on intensive laboratory techniques. We investigated how combining different rapid diagnostic tests (RDTs) can be used to accurately determine the primary and post-primary DENV immune status of reporting patients during diagnosis.Methods and findingsSerum from cross-sectional surveys of acute suspected dengue patients in Indonesia (N:200) and Vietnam (N: 1,217) were assayed using dengue laboratory assays and RDTs. Using logistic regression modelling, we determined the probability of being DENV NS1, IgM and IgG RDT positive according to corresponding laboratory viremia, IgM and IgG ELISA metrics. Laboratory test thresholds for RDT positivity/negativity were calculated using Youden’s J index and were utilized to estimate the RDT outcomes in patients from the Philippines, where only data for viremia, IgM and IgG were available (N:28,326). Lastly, the probabilities of being primary or post-primary according to every outcome using all RDTs, by day of fever, were calculated. Combining NS1, IgM and IgG RDTs captured 94.6% (52/55) and 95.4% (104/109) of laboratory-confirmed primary and post-primary DENV cases, respectively, during the first 5 days of fever. Laboratory test predicted, and actual, RDT outcomes had high agreement (79.5% (159/200)). Among patients from the Philippines, different combinations of estimated RDT outcomes were indicative of post-primary and primary immune status. Overall, IgG RDT positive results were confirmatory of post-primary infections. In contrast, IgG RDT negative results were suggestive of both primary and post-primary infections on days 1–2 of fever, yet were confirmatory of primary infections on days 3–5 of fever.ConclusionWe demonstrate how the primary and post-primary DENV immune status of reporting patients can be estimated at the point of care by combining NS1, IgM and IgG RDTs and considering the days since symptoms onset. This framework has the potential to strengthen surveillance operations and dengue prognosis, particularly in low resource settings.  相似文献   

7.
8.

Background

Although rapid diagnostic tests (RDTs) have practical advantages over light microscopy (LM) and good sensitivity in severe falciparum malaria in Africa, their utility where severe non-falciparum malaria occurs is unknown. LM, RDTs and polymerase chain reaction (PCR)-based methods have limitations, and thus conventional comparative malaria diagnostic studies employ imperfect gold standards. We assessed whether, using Bayesian latent class models (LCMs) which do not require a reference method, RDTs could safely direct initial anti-infective therapy in severe ill children from an area of hyperendemic transmission of both Plasmodium falciparum and P. vivax.

Methods and Findings

We studied 797 Papua New Guinean children hospitalized with well-characterized severe illness for whom LM, RDT and nested PCR (nPCR) results were available. For any severe malaria, the estimated prevalence was 47.5% with RDTs exhibiting similar sensitivity and negative predictive value (NPV) to nPCR (≥96.0%). LM was the least sensitive test (87.4%) and had the lowest NPV (89.7%), but had the highest specificity (99.1%) and positive predictive value (98.9%). For severe falciparum malaria (prevalence 42.9%), the findings were similar. For non-falciparum severe malaria (prevalence 6.9%), no test had the WHO-recommended sensitivity and specificity of >95% and >90%, respectively. RDTs were the least sensitive (69.6%) and had the lowest NPV (96.7%).

Conclusions

RDTs appear a valuable point-of-care test that is at least equivalent to LM in diagnosing severe falciparum malaria in this epidemiologic situation. None of the tests had the required sensitivity/specificity for severe non-falciparum malaria but the number of false-negative RDTs in this group was small.  相似文献   

9.

Background

In the absence of well-equipped laboratory infrastructure in many developing countries the accurate diagnosis of typhoid fever is challenging. Rapid diagnostic tests (RDT) with good performance indicators would be helpful to improve clinical management of suspected cases. We performed a systematic literature review and meta- analysis to determine the performance of TUBEX TF and Typhidot for the diagnosis of typhoid fever using PRISMA guidelines.

Methods

Titles and abstracts were reviewed for relevance. Articles were screened for language, reference method and completeness. Studies were categorized according to control groups used. Meta-analysis was performed only for categories where enough data was available to combine sensitivity and specificity estimates. Sub-analysis was performed for the Typhidot test to determine the influence of indeterminate results on test performance.

Results

A total of seven studies per test were included. The sensitivity of TUBEX TF ranged between 56% and 95%, Specificity between 72% and 95%. Meta-analysis showed an average sensitivity of 69% (95%CI: 45–85) and an average specificity of 88% (CI95%:83–91). A formal meta-analysis for Typhidot was not possible due to limited data available. Across the extracted studies, sensitivity and specificity estimates ranged from 56% to 84% and 31% to 97% respectively.

Conclusion

The observed performance does not support the use of either rapid diagnostic test exclusively as the basis for diagnosis and treatment. There is a need to develop an RDT for typhoid fever that has a performance level comparable to malaria RDTs.  相似文献   

10.
BackgroundZoonoses are common causes of human and livestock illness in Tanzania. Previous studies have shown that brucellosis, leptospirosis, and Q fever account for a large proportion of human febrile illness in northern Tanzania, yet they are infrequently diagnosed. We conducted this study to assess awareness and knowledge regarding selected zoonoses among healthcare providers in Moshi, Tanzania; to determine what diagnostic and treatment protocols are utilized; and obtain insights into contextual factors contributing to the apparent under-diagnosis of zoonoses.Methodology/ResultsWe conducted a questionnaire about zoonoses knowledge, case reporting, and testing with 52 human health practitioners and 10 livestock health providers. Immediately following questionnaire administration, we conducted semi-structured interviews with 60 of these respondents, using the findings of a previous fever etiology study to prompt conversation. Sixty respondents (97%) had heard of brucellosis, 26 (42%) leptospirosis, and 20 (32%) Q fever. Animal sector respondents reported seeing cases of animal brucellosis (4), rabies (4), and anthrax (3) in the previous 12 months. Human sector respondents reported cases of human brucellosis (15, 29%), rabies (9, 18%) and anthrax (6, 12%). None reported leptospirosis or Q fever cases. Nineteen respondents were aware of a local diagnostic test for human brucellosis. Reports of tests for human leptospirosis or Q fever, or for any of the study pathogens in animals, were rare. Many respondents expressed awareness of malaria over-diagnosis and zoonoses under-diagnosis, and many identified low knowledge and testing capacity as reasons for zoonoses under-diagnosis.ConclusionsThis study revealed differences in knowledge of different zoonoses and low case report frequencies of brucellosis, leptospirosis, and Q fever. There was a lack of known diagnostic services for leptospirosis and Q fever. These findings emphasize a need for improved diagnostic capacity alongside healthcare provider education and improved clinical guidelines for syndrome-based disease management to provoke diagnostic consideration of locally relevant zoonoses in the absence of laboratory confirmation.  相似文献   

11.

Background

Early diagnosis of dengue virus (DENV) infection can improve clinical outcomes by ensuring close follow-up, initiating appropriate supportive therapies and raising awareness to the potential of hemorrhage or shock. Non-structural glycoprotein-1 (NS1) has proven to be a useful biomarker for early diagnosis of dengue. A number of rapid diagnostic tests (RDTs) and enzyme-linked immunosorbent assays (ELISAs) targeting NS1 antigen (Ag) are now commercially available. Here we evaluated these tests using a well-characterized panel of clinical samples to determine their effectiveness for early diagnosis.

Methodology/Principal Findings

Retrospective samples from South America were used to evaluate the following tests: (i) “Dengue NS1 Ag STRIP” and (ii) “Platelia Dengue NS1 Ag ELISA” (Bio-Rad, France), (iii) “Dengue NS1 Detect Rapid Test (1st Generation)” and (iv) “DENV Detect NS1 ELISA” (InBios International, United States), (v) “Panbio Dengue Early Rapid (1st generation)” (vi) “Panbio Dengue Early ELISA (2nd generation)” and (vii) “SD Bioline Dengue NS1 Ag Rapid Test” (Alere, United States). Overall, the sensitivity of the RDTs ranged from 71.9%–79.1% while the sensitivity of the ELISAs varied between 85.6–95.9%, using virus isolation as the reference method. Most tests had lower sensitivity for DENV-4 relative to the other three serotypes, were less sensitive in detecting secondary infections, and appeared to be most sensitive on Day 3–4 post symptom onset. The specificity of all evaluated tests ranged from 95%–100%.

Conclusions

ELISAs had greater overall sensitivity than RDTs. In conjunction with other parameters, the performance data can help determine which dengue diagnostics should be used during the first few days of illness, when the patients are most likely to present to a clinic seeking care.  相似文献   

12.
BackgroundChikungunya virus (CHIKV) causes febrile illnesses and has always been misdiagnosed as other viral infections, such as dengue and Zika; thus, a laboratory test is needed. Serological tests are commonly used to diagnose CHIKV infection, but their accuracy is questionable due to varying degrees of reported sensitivities and specificities. Herein, we conducted a systematic review and meta-analysis to evaluate the diagnostic accuracy of serological tests currently available for CHIKV.Methodology and principal findingsA literature search was performed in PubMed, CINAHL Complete, and Scopus databases from the 1st December 2020 until 22nd April 2021. Studies reporting sensitivity and specificity of serological tests against CHIKV that used whole blood, serum, or plasma were included. QUADAS-2 tool was used to assess the risk of bias and applicability, while R software was used for statistical analyses.Thirty-five studies were included in this meta-analysis; 72 index test data were extracted and analysed. Rapid and ELISA-based antigen tests had a pooled sensitivity of 85.8% and 82.2%, respectively, and a pooled specificity of 96.1% and 96.0%, respectively. According to our meta-analysis, antigen detection tests serve as a good diagnostic test for acute-phase samples. The IgM detection tests had more than 90% diagnostic accuracy for ELISA-based tests, immunofluorescence assays, in-house developed tests, and samples collected after seven days of symptom onset. Conversely, low sensitivity was found for the IgM rapid test (42.3%), commercial test (78.6%), and for samples collected less than seven of symptom onset (26.2%). Although IgM antibodies start to develop on day 2 of CHIKV infection, our meta-analysis revealed that the IgM detection test is not recommended for acute-phase samples. The diagnostic performance of the IgG detection tests was more than 93% regardless of the test formats and whether the test was commercially available or developed in-house. The use of samples collected after seven days of symptom onset for the IgG detection test suggests that IgG antibodies can be detected in the convalescent-phase samples. Additionally, we evaluated commercial IgM and IgG tests for CHIKV and found that ELISA-based and IFA commercial tests manufactured by Euroimmun (Lübeck, Germany), Abcam (Cambridge, UK), and Inbios (Seattle, WA) had diagnostic accuracy of above 90%, which was similar to the manufacturers’ claim.ConclusionBased on our meta-analysis, antigen or antibody-based serological tests can be used to diagnose CHIKV reliably, depending on the time of sample collection. The antigen detection tests serve as a good diagnostic test for samples collected during the acute phase (≤7 days post symptom onset) of CHIKV infection. Likewise, IgM and IgG detection tests can be used for samples collected in the convalescent phase (>7 days post symptom onset). In correlation to the clinical presentation of the patients, the combination of the IgM and IgG tests can differentiate recent and past infections.  相似文献   

13.
BackgroundLeptospirosis has globally significant human mortality and morbidity, yet estimating the clinical and public health burden of leptospirosis is challenging because timely diagnosis remains limited. The goal of the present study was to evaluate leptospirosis undercounting by current standard methods in both clinical and epidemiological study settings.Methodology/Principal findingsA prospective hospital-based study was conducted in multiple hospitals in Sri Lanka from 2016 to 2019. Culture, whole blood, and urine samples were collected from clinically suspected leptospirosis cases and patients with undifferentiated fever. Analysis of biological samples from 1,734 subjects confirmed 591 (34.1%) cases as leptospirosis and 297 (17.1%) were classified as “probable” leptospirosis cases. Whole blood quantitative PCR (qPCR) did identify the most cases (322/540(60%)) but missed 40%. Cases missed by each method include; urine qPCR, 70% (153/220); acute sample microscopic agglutination test (MAT), 80% (409/510); paired serum sample MAT, 58% (98/170); and surveillance clinical case definition, 53% (265/496). qPCR of negative culture samples after six months of observation was of diagnostic value retrospectively with but missed 58% of positives (109/353).ConclusionLeptospirosis disease burden estimates should consider the limitations of standard diagnostic tests. qPCR of multiple sample types should be used as a leading standard test for diagnosing acute leptospirosis.  相似文献   

14.

Background

Individual rapid tests for serodiagnosis (RDT) of human African trypanosomiasis (HAT) are particularly suited for passive screening and surveillance. However, so far, no large scale evaluation of RDTs has been performed for diagnosis of Trypanosoma brucei gambiense HAT in West Africa. The objective of this study was to assess the diagnostic accuracy of 2 commercial HAT-RDTs on stored plasma samples from West Africa.

Methodology/Principal findings

SD Bioline HAT and HAT Sero-K-Set were performed on 722 plasma samples originating from Guinea and Côte d’Ivoire, including 231 parasitologically confirmed HAT patients, 257 healthy controls, and 234 unconfirmed individuals whose blood tested antibody positive in the card agglutination test but negative by parasitological tests. Immune trypanolysis was performed as a reference test for trypanosome specific antibody presence. Sensitivities in HAT patients were respectively 99.6% for SD Bioline HAT, and 99.1% for HAT Sero-K-Set, specificities in healthy controls were respectively 87.9% and 88.3%. Considering combined positivity in both RDTs, increased the specificity significantly (p≤0.0003) to 93.4%, while 98.7% sensitivity was maintained. Specificities in controls were 98.7–99.6% for the combination of one or two RDTs with trypanolysis, maintaining a sensitivity of at least 98.1%.

Conclusions/Significance

The observed specificity of the single RDTs was relatively low. Serial application of SD Bioline HAT and HAT Sero-K-Set might offer superior specificity compared to a single RDT, maintaining high sensitivity. The combination of one or two RDTs with trypanolysis seems promising for HAT surveillance.  相似文献   

15.
Currently available rapid diagnostic tests (RDTs) for malaria show large variation in sensitivity and specificity, and there are concerns about their stability under field conditions. To improve current RDTs, monoclonal antibodies (mAbs) for novel malaria antigens have been developed and screened for their possible use in new diagnostic tests. Three antigens, glutamate rich protein (GLURP), dihydrofolate reductase-thymidylate synthase (DHFR-TS) and heme detoxification protein (HDP), were selected based on literature searches. Recombinant antigens were produced and used to immunize mice. Antibody-producing cell lines were subsequently selected and the resulting antibodies were screened for specificity against Plasmodium falciparum and Plasmodium vivax. The most optimal antibody couples were selected based on antibody affinity (expressed as dissociation constants, KD) and detection limit of crude antigen extract from P. falciparum 3D7 culture. The highest affinity antibodies have KD values of 0.10 nM ± 0.014 (D5) and 0.068 ± 0.015 nM (D6) for DHFR-TS mAbs, 0.10 ± 0.022 nM (H16) and 0.21 ± 0.022 nM (H18) for HDP mAbs and 0.11 ± 0.028 nM (G23) and 0.33 ± 0.093 nM (G22) for GLURP mAbs. The newly developed antibodies performed at least as well as commercially available histidine rich protein antibodies (KD of 0.16 ± 0.13 nM for PTL3 and 1.0 ± 0.049 nM for C1–13), making them promising reagents for further test development.Key words: plasmodium, Plasmodium falciparum, malaria, diagnostics, rapid diagnostic test, monoclonal antibodies, glutamate rich protein, dihydrofolate reductase-thymidylate synthase, heme detoxification protein  相似文献   

16.
Leptospirosis is an important global zoonotic disease caused by pathogenic Leptospira spp. species. Swine leptospirosis has a major economic impact because pigs are sources of animal protein and by-products. The signs of swine leptospirosis are abortion, stillbirth, birth of weak or ill piglets, appearing 14–60 days after infection. The reference method for diagnosis of leptospirosis is the microscopic agglutination test (MAT), in which serum samples are reacted with live antigen suspensions of leptospiral serovars. However, MAT is laborious and time consuming as a diagnostic procedure when dealing with a large number of samples; therefore, efforts are being made to develop novel, sensitive, and specific diagnostic tests for leptospirosis. In this study, a recombinant LipL32 based on enzyme-linked immunosorbent assay (rLipL32/ELISA) was evaluated as a screening test for the detection of pathogenic leptospiral-specific antibodies. A total of 86 swine serum samples tested by MAT were used to develop rLipL32/ELISA. Compared to positive and negative sera tested by MAT, rLipL32/ELISA showed 100 % sensitivity, 85.1 % specificity, and 91.86 % accuracy. No positive reaction for other bacterial diseases (enzootic pneumonia and brucellosis) was observed. The rLipL32/ELISA reported in this study is a specific, sensitive, and convenient test for the detection of antibodies against swine leptospiral infection and can be used as a rapid screening test in epidemiological surveys.  相似文献   

17.
BackgroundDengue fever is highly endemic in Vietnam, but scrub typhus—although recognized as an endemic disease—remains underappreciated. These diseases together are likely to account for more than half of the acute undifferentiated fever burden in Vietnam. Scrub typhus (ST) is a bacterial disease requiring antimicrobial treatment, while dengue fever (DF) is of viral etiology and does not. The access to adequate diagnostics and the current understanding of empirical treatment strategies for both illnesses remain limited. In this study we aimed to contribute to the clinical decision process in the management of these two important etiologies of febrile illness in Vietnam.MethodsUsing retrospective data from 221 PCR-confirmed scrub typhus cases and 387 NS1 protein positive dengue fever patients admitted to five hospitals in Khanh Hoa province (central Vietnam), we defined predictive characteristics for both diseases that support simple clinical decision making with potential to inform decision algorithms in future. We developed models to discriminate scrub typhus from dengue fever using multivariable logistic regression (M-LR) and classification and regression trees (CART). Regression trees were developed for the entire data set initially and pruned, based on cross-validation. Regression models were developed in a training data set involving 60% of the total sample and validated in the complementary subsample. Probability cut points for the distinction between scrub typhus and dengue fever were chosen to maximise the sum of sensitivity and specificity.ResultsUsing M-LR, following seven predictors were identified, that reliably differentiate ST from DF; eschar, regional lymphadenopathy, an occupation in nature, increased days of fever on admission, increased neutrophil count, decreased ratio of neutrophils/lymphocytes, and age over 40. Sensitivity and specificity of predictions based on these seven factors reached 93.7% and 99.5%, respectively. When excluding the “eschar” variable, the values dropped to 76.3% and 92.3%, respectively.The CART model generated one further variable; increased days of fever on admission, when eschar was included, the sensitivity and specificity was 95% and 96.9%, respectively. The model without eschar involved the following six variables; regional lymphadenopathy, increased days of fever on admission, increased neutrophil count, increased lymphocyte count, platelet count ≥ 47 G/L and age over 28 years as predictors of ST and provided a sensitivity of 77.4% and a specificity of 90.7%.ConclusionsThe generated algorithms contribute to differentiating scrub typhus from dengue fever using basic clinical and laboratory parameters, supporting clinical decision making in areas where dengue and scrub typhus are co-endemic in Vietnam.  相似文献   

18.
BackgroundLittle is known about the diagnostic performance of rapid diagnostic tests (RDTs) for passive screening of human African trypanosomiasis (HAT) in Côte d’Ivoire. We determined HAT prevalence among clinical suspects, identified clinical symptoms and signs associated with HAT RDT positivity, and assessed the diagnostic tests’ specificity, positive predictive value and agreement.MethodsClinical suspects were screened with SD Bioline HAT, HAT Sero-K-Set and rHAT Sero-Strip. Seropositives were parasitologically examined, and their dried blood spots tested in trypanolysis, ELISA/Tbg, m18S-qPCR and LAMP. The HAT prevalence in the study population was calculated based on RDT positivity followed by parasitological confirmation. The association between clinical symptoms and signs and RDT positivity was determined using multivariable logistic regression. The tests’ Positive Predictive Value (PPV), specificity and agreement were determined.ResultsOver 29 months, 3433 clinical suspects were tested. The RDT positivity rate was 2.83%, HAT prevalence 0.06%. Individuals with sleep disturbances (p<0.001), motor disorders (p = 0.002), convulsions (p = 0.02), severe weight loss (p = 0.02) or psychiatric problems (p = 0.04) had an increased odds (odds ratios 1.7–4.6) of being HAT RDT seropositive. Specificities ranged between 97.8%-99.6% for individual RDTs, and 93.3–98.9% for subsequent tests on dried blood spots. The PPV of the individual RDTs was below 14.3% (CI 2–43), increased to 33.3% (CI 4–78) for serial RDT combinations, and reached 67% for LAMP and ELISA/Tbg on RDT positives. Agreement between diagnostic tests was poor to moderate (Kappa ≤ 0.60), except for LAMP and ELISA/Tbg (Kappa = 0.66).ConclusionIdentification of five key clinical symptoms and signs may simplify referral for HAT RDT screening. The results confirm the appropriateness of the diagnostic algorithm presently applied, with screening by SD Bioline HAT or HAT Sero-K-Set, supplemented with trypanolysis. ELISA/Tbg could replace trypanolysis and is simpler to perform.Trial registrationClinicalTrials.gov NCT03356665.  相似文献   

19.

Background

In the Peruvian Amazon, Plasmodium falciparum and Plasmodium vivax malaria are endemic in rural areas, where microscopy is not available. Malaria rapid diagnostic tests (RDTs) provide quick and accurate diagnosis. However, pfhrp2 gene deletions may limit the use of histidine-rich protein-2 (PfHRP2) detecting RDTs. Further, cross-reactions of P. falciparum with P. vivax-specific test lines and vice versa may impair diagnostic specificity.

Methods

Thirteen RDT products were evaluated on 179 prospectively collected malaria positive samples. Species diagnosis was performed by microscopy and confirmed by PCR. Pfhrp2 gene deletions were assessed by PCR.

Results

Sensitivity for P. falciparum diagnosis was lower for PfHRP2 compared to P. falciparum-specific Plasmodium lactate dehydrogenase (Pf-pLDH)- detecting RDTs (71.6% vs. 98.7%, p<0.001). Most (19/21) false negative PfHRP2 results were associated with pfhrp2 gene deletions (25.7% of 74 P. falciparum samples). Diagnostic sensitivity for P. vivax (101 samples) was excellent, except for two products. In 10/12 P. vivax-detecting RDT products, cross-reactions with the PfHRP2 or Pf-pLDH line occurred at a median frequency of 2.5% (range 0%–10.9%) of P. vivax samples assessed. In two RDT products, two and one P. falciparum samples respectively cross-reacted with the Pv-pLDH line. Two Pf-pLDH/pan-pLDH-detecting RDTs showed excellent sensitivity with few (1.0%) cross-reactions but showed faint Pf-pLDH lines in 24.7% and 38.9% of P. falciparum samples.

Conclusion

PfHRP2-detecting RDTs are not suitable in the Peruvian Amazon due to pfhrp2 gene deletions. Two Pf-pLDH-detecting RDTs performed excellently and are promising RDTs for this region although faint test lines are of concern.  相似文献   