首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Quartz crystal microbalance (QCM) sensors are widely used for determining liquid properties or probing interfacial processes. For some applications the sensitivity of the QCM sensors typically used (5–20 MHz) is limited compared with other biosensor methods. In this study ultrasensitive QCM sensors with resonant frequencies from 39 to 110 MHz for measurements in the liquid phase are presented. The fundamental sensor effect of a QCM is the decrease of the resonant frequency of an oscillating quartz crystal due to the binding of mass on a coated surface during the measurement. The sensitivity of QCM sensors increases strongly with an increasing resonant frequency and, therefore, with a decreasing thickness of the sensitive area. The new kind of ultrasensitive QCM sensors used in this study is based on chemically milled shear mode quartz crystals which are etched only in the center of the blank, forming a thin quartz membrane with a thick, mechanically stable outer ring. An immunoassay using a virus specific monoclonal antibody and a M13-Phage showed an increase in the signal to noise ratio by a factor of more than 6 for 56 MHz quartz crystals compared with standard 19 MHz quartz crystals, the detection limit was improved by a factor of 200. Probing of acoustic properties of glycerol/water mixtures resulted in an increase in sensitivity, which is in very good agreement with theory. Chemically milled QCM sensors strongly improve the sensitivity in biosensing and probing of acoustic properties and, therefore, offer interesting new application fields for QCM sensors.  相似文献   

2.
The aim of this work is to study the effect of operating frequency, piezoelectric substrate and waveguide layer thickness on the sensitivity of the acoustic waveguide sensor during the specific binding of an antibody by a protein. Shear horizontal (SH) wave devices consisting of (a) a LiTaO3 substrate operating at 104 MHz, (b) a quartz substrate operating at 108 MHz and (c) a quartz substrate operating at 155 MHz were coated with a photoresist polymer layer in order to produce acoustic waveguide devices supporting a Love wave. The effect of the thickness of the polymer layer on the Love wave was assessed by measuring the amplitude and phase of the wave before and after coating. The sensitivity of the above three biosensors was compared during the detection of the specific binding of different concentrations of Immunoglobulin G in the range of 0.7-667 nM to a protein A modified surface. Results indicate that the thickness of the polymer guiding layer is critical for obtaining the maximum sensitivity for a given geometry but a trade-off has to be made between the theoretically determined optimum thickness for waveguiding and the device insertion loss. It was also found that increasing the frequency of operation results in a further increase in the device sensitivity to protein detection.  相似文献   

3.
In this paper a new technique is proposed to determine the acoustic properties as well as the thickness (and volume) of biological cells. Variations of thickness, density, acoustic wave velocity, stiffness, and attenuation coefficient of a living or dead cell are obtained by scanning the cell by an acoustic microscope. The distance between the cell and the microscope lens is varied and several voltage curves are thus obtained. These curves are then inverted by simplex optimization technique to obtain the cell parameters. The spatial resolution of the method is limited to the resolution of the scanning acoustic microscope. It allows to take advantage of the full range of frequencies and amplification of the microscope. Characteristic distributions of stiffness are exemplified with an endothelial cell in culture. The main part of the thin, lamellar cytoplasm has high stiffness, which drops close to the lamella/cell body transition region and only slightly increases again through the central part of the cell. Acoustic attenuation seems to be related to two factors, cytoplasm accumulation (in the lamellar parts) and scattering in the central part rich in organelles.  相似文献   

4.
A tunable acoustic biosensor for investigating the properties of biomolecules at the solid-liquid interfaces is described. In its current, format the device can be tuned to frequencies between 6.5 MHz and 1.1 GHz in order to provide a unique detection feature: a variable evanescent wave thickness at the sensor surface. The key to its successful implementation required the careful selection of antennae designs that could induce shear acoustic waves at the solid-liquid interface. This non-contact format makes it possible to recover resonant shear acoustic waves over 100 different harmonic frequencies as a result of the electrical characteristics of the spiral coil. For testing this multifrequency sensing concept the surface of a quartz disc was exposed to solutions of immunoglobulin G (IgG) to form an adsorbed monolayer, whence protein A and IgG were added again in order to form multilayers. Spectra at frequencies between 6 and 600 MHz were generated for each successive layer and revealed two characteristic phases: an initial phase at the low megahertz frequencies consistent with the conventional Sauerbrey relation, and a possible additional phase towards the high megahertz to gigahertz frequencies, that we believe relates to the structure of the biomolecular film. This two-phase behaviour evident from differences between high and low frequencies, rather than from any distinct frequency transition, was anticipated from the reduction in evanescent wave thickness down to nanometre dimensions, and thin film resonance phenomena that are known to occur for film and fluid systems. These measurements suggested that the single element acoustic biosensor we present here may form the basis from which to generate acoustic molecular spectra, or "acoustic fingerprints", in a manner akin to optical spectroscopy.  相似文献   

5.
In this work, we describe a novel pulse mode shear horizontal-surface acoustic wave (SH-SAW) polymer coated biosensor that monitors rapid changes in both amplitude and phase. The SH-SAW sensors were fabricated on 36 degrees rotated Y-cut X propagating lithium tantalate (36 YX.LT). The sensitivity of the device to both mass loading and visco-elastic effects may be increased by using a thin guiding layer of cross-linked polymer. Two acoustic modes are excited by the electrodes in this crystalline direction. Metallisation of the propagation path of the 36 YX.LT devices allows the two modes to be discriminated. Successive polymer coatings resulted in the observation of resonant conditions in both modes as the layer thickness was increased. Using the 36 YX.LT devices, we have investigated the application of a novel pulse mode system by sensing a sequence of deposition and removal of a biological layer consisting of vesicles of the phospholipid POPC. A continuous wave system was used to verify the accuracy of the pulse mode system by sensing a series of poly(ethylene glycol) (PEG) solutions. The data clearly demonstrates the ability of the 36 YX.LT pulse mode system to provide rapid measurements of both amplitude and phase for biosensing applications.  相似文献   

6.
A voltage clamp consisting of a sinusoidal voltage of amplitude V1 and frequency f, superimposed on a steady voltage level V0, is applied to the Hodgkin-Huxley model of the squid giant axon membrane. The steady-state response is a current composed of sinusoidal components of frequencies O, f, 2f, 3f,... The frequencies greater than f arise from the nonlinearity of the membrane. The total current is described by a power series in V1; each coefficient of this series is composed of current components for one or more frequencies. For different frequencies one can derive higher-order generalized admittances characterizing the nonlinear as well as the linear properties of the membrane. Formulas for the generalized admittances are derived from the Hodgkin-Huxley equations for frequencies up to 3f, using a perturbation technique. Some of the resulting theoretical curves are compared with experimental results, with good qualitative agreement.  相似文献   

7.
The broad-band ultrasonic spectroscopy technique allows the determination of changes in the relative water content (RWC) of leaves with contrasting structural features. Specifically, the standardized frequency associated with the maximum transmittance (f/f(o)) is strongly related to the RWC. This relationship is characterized by the existence of two phases separated by an inflexion point (associated with the turgor loss point). To obtain a better understanding of the strong relationship found between RWC and f/f(o), this work has studied the structural changes experienced by Quercus muehlenbergii leaves during dehydration in terms of ultrasounds measurements, cell wall elasticity, leaf thickness, leaf density, and leaf structure. The results suggest that the decrease found in f/f(o) before the turgor loss point can be attributed to the occurrence of changes in the estimation of the macroscopic effective elastic constant of the leaf (c(33)), mainly associated with changes in the bulk modulus of elasticity of the cell wall (ε). These changes are overriding or compensating for the thickness decreases recorded during this phase. On the other hand, the high degree of cell shrinkage and stretching found in the mesophyll cells during the second phase seem to explain the changes in the acoustic properties of the leaf beyond the turgor loss point. The formation of large intercellular spaces, which increased the irregularity in the acoustic pathway, may explain the increase of the attenuation coefficient of ultrasounds once the turgor loss point threshold is exceeded. The direct measurement of c(33) from ultrasonic measurements would allow a better knowledge of the overall biomechanical properties of the leaf further than those derived from the P-V analysis.  相似文献   

8.
Surface acoustic wave sensors operating in liquid generally cause problems resulting from wire bonding. The authors present an approach for a biosensor where the need for bonding wires is eliminated by utilizing inductive coupling of the sensor device to the RF circuitry. Protection of the electrodes from the liquid is achieved by coating the device surface with a SiO2 layer, resulting in a simplified handling of the devices. The first measurements with a sensor operating at 420 MHz are presented, demonstrating the potential of this operating principle for biosensing.  相似文献   

9.
The capture of Bacillus subtilis var. niger spores on an antibody-coated surface can be enhanced when that coated surface acts as an acoustic reflector in a quarter wavelength ultrasonic (3 MHz) standing wave resonator. Immunocapture in such a resonator has been characterised here for both spores and 1 microm diameter biotinylated fluorescent microparticles. A mean spatial acoustic pressure amplitude of 460 kPa and a frequency of 2.82 MHz gave high capture efficiencies. It was shown that capture was critically dependent on reflector thickness. The time dependence of particle deposition on a reflector in a batch system was broadly consistent with a calculated time of 35 s to bring 95% of particles to the coated surface. A suspension flow rate of 0.1 ml/min and a reflector thickness of 1.01 mm gave optimal capture in a 2 min assay. The enhancement of particle detection compared with the control (no ultrasound) situation was x 70. The system detects a total of five particles in 15 fields of view in a 2 min assay when the suspending phase concentration was 10(4) particles/ml. A general expression for the dependence of minimum concentration detectable on; number of fields examined, sample volume flowing through the chamber and assay time shows that, for a practical combination of these variables, the threshold detection concentration can be two orders of magnitude lower.  相似文献   

10.
A H+-selective liquid membrane microelectrode was prepared and used to measure the pH profile evolution during colonization of gel beads immobilizing Lactobacillus helveticus in a whey permeate medium. A large pH gradient was observed in a highly active periferal layer thickness that decreased from 500 to 300 m for an immobilized cell population that increased from 5.8 × 109 to 3.1 × 1010 CFU/g. The flat pH profile (pH 4.4) in the central part of the bead was attributed to a high concentration of the inhibitory undissociated form of lactic acid.  相似文献   

11.
《Biophysical journal》2020,118(7):1564-1575
The endothelial glycocalyx layer (EGL), which consists of long proteoglycans protruding from the endothelium, acts as a regulator of inflammation by preventing leukocyte engagement with adhesion molecules on the endothelial surface. The amount of resistance to adhesive events the EGL provides is the result of two properties: EGL thickness and stiffness. To determine these, we used an atomic force microscope to indent the surfaces of cultured endothelial cells with a glass bead and evaluated two different approaches for interpreting the resulting force-indentation curves. In one, we treat the EGL as a molecular brush, and in the other, we treat it as a thin elastic layer on an elastic half-space. The latter approach proved more robust in our hands and yielded a thickness of 110 nm and a modulus of 0.025 kPa. Neither value showed significant dependence on indentation rate. The brush model indicated a larger layer thickness (∼350 nm) but tended to result in larger uncertainties in the fitted parameters. The modulus of the endothelial cell was determined to be 3.0–6.5 kPa (1.5–2.5 kPa for the brush model), with a significant increase in modulus with increasing indentation rates. For forces and leukocyte properties in the physiological range, a model of a leukocyte interacting with the endothelium predicts that the number of molecules within bonding range should decrease by an order of magnitude because of the presence of a 110-nm-thick layer and even further for a glycocalyx with larger thickness. Consistent with these predictions, neutrophil adhesion increased for endothelial cells with reduced EGL thickness because they were grown in the absence of fluid shear stress. These studies establish a framework for understanding how glycocalyx layers with different thickness and stiffness limit adhesive events under homeostatic conditions and how glycocalyx damage or removal will increase leukocyte adhesion potential during inflammation.  相似文献   

12.
The composition of virenomycin, a new antitumor antibiotic was studied. Two components V and M were detected with high resolution liquid chromatography and thin layer chromatography on siluphol (Czechoslovakia) and silica gel (Merk, BRD). A preparative method for separation of the antibiotic components with the use of chromatography on columns with silica gel was developed. Biological and physicochemical properties of separate components were studied to show that they significantly differed by their antibacterial action in vitro: virenomycin V was 2 to 4 times more active than virenomycin M against a number of microbes. The physicochemical properties of the components are similar. It was shown with mass spectrometry that the molecular weight of virenomycin is 12 units higher than that of virenomycin M. The PMR spectra showed that this difference is due to the presence of a vinyl group in the chromophore moiety of the virenomycin V molecule and a methyl group at the similar site of the virenomycin M molecule.  相似文献   

13.
The thickness shear mode (TSM) acoustic wave sensor attached with living cells has been shown to be an effective functional biosensing device to monitor the process of cell adhesion to a surface in real time. In this study, a multilayer sensor model that includes a quartz substrate, a cell-substrate interfacial layer and a cell layer was constructed based on the state of cell adhesion to the substrate. The dynamic process of cell adhesions as a function of cell seeding densities was monitored using the acoustic wave sensor. The mechanisms that are responsible for the frequency and resistance change are discussed according to the predictions of the acoustic wave sensor model. In addition, knowing that the actin cytoskeleton is important for cell adhesion, we investigated the motional resistance change caused by the disruption of actin cytoskeleton induced by fungal toxin cytochalasin D in the human skin fibroblasts. The results indicate that resistance changes are related to the disruption of actin cytoskeleton and dosage-dependent.  相似文献   

14.
The thin layer of liquid at the surface of airway epithelium, the airway surface liquid (ASL), is important in normal airway physiology and in the pathophysiology of cystic fibrosis. At present, the best method to measure ASL depth involves scanning confocal microscopy after staining with an aqueous-phase fluorescent dye. We describe here a simple, noninvasive imaging method to measure ASL depth by reflectance imaging of an epithelial mucosa in which the surface is illuminated at a 45-degree angle by an elongated 13-µm wide rectangular beam produced by a 670-nm micro-focus laser. The principle of the method is that air–liquid, liquid–liquid, and liquid–cell interfaces produce distinct specular or diffuse reflections that can be imaged to give a micron-resolution replica of the mucosal surface. The method was validated using fluid layers of specified thicknesses and applied to measure ASL depth in cell cultures and ex vivo fragments of pig trachea. In addition, the method was adapted to measure transepithelial fluid transport from the dynamics of fluid layer depth. Compared with confocal imaging, ASL depth measurement by surface laser reflectance microscopy does not require dye staining or costly instrumentation, and can potentially be adapted for in vivo measurements using fiberoptics.  相似文献   

15.
In label-free biodetections based on microcantilever technology, double-stranded DNA (dsDNA) structures form through the linkage between probe single-stranded DNA (ssDNA) molecules immobilized on solid substrates and target ssDNA molecules in solutions. Mechanical/electrical properties of these biolayers are important factors for nanomechanical deflections of microcantilevers. In this paper, the biolayer immobilized on microcantilever is treated as a bar with a macroscopic elastic modulus on the basis of continuum mechanics viewpoints. In consideration of hydration force, screened electrostatic repulsion and conformational fluctuation in biolayers, load-deformation curves of dsDNA biolayers under axial compression are depicted with the help of the energy conservation law and a mesoscopic free energy presented by Strey et al. (1997, 1999) [Strey, H.H., Parsegian, V.A., Podgornik, R., 1997. Equation of state for DNA liquid crystals: fluctuation enhanced electrostatic double layer repulsion. Physical Review Letters 78, 895–898; Strey, H.H., Parsegian, V.A., Podgornik, R., 1999. Equation of state for polymer liquid crystals: theory and experiment. Physical Review E 59, 999–1008] from a liquid crystal theory. And the analytical relation between macroscopic Young's modulus of biolayers and nanoscopic geometrical properties of dsDNA, packing density, buffer salt solution concentration, etc. is also formulated.  相似文献   

16.
To determine how protein kinase C (PKC) activity influences properties of the tetrodotoxin-resistant sodium current (TTX-R I(Na)) in neonatal rat nodose ganglion (NG) neurons, we assessed the effects of phorbol,-12-myristate,13-acetate (PMA), one of the PKC activators, and staurosporine, one of the PKC inhibitors, on the current. PMA (30 and 100 nM) induced an increase in the peak current amplitude of normalized current-voltage curves, a leftward shift in the potential for half activation (V(1/2)) of normalized conductance-voltage curves and a leftward shift of V(1/2) potential for steady-state inactivation curves. The effects of staurosporine (0.1 and 1 muM) on the peak current amplitude and the V(1/2) potential for activation were opposite compared with those seen after PMA application. Staurosporine (1 muM) antagonized PMA (100 nM)-induced modification of TTX-R I(Na). These results suggest that the basal TTX-R I(Na) obtained from neonatal NG neurons is controlled by the level of PKC activity.  相似文献   

17.
Currently, little is known about the mechanical properties of filamentous fungal hyphae. To study this topic, atomic force microscopy (AFM) was used to measure cell wall mechanical properties of the model fungus Aspergillus nidulans. Wild type and a mutant strain (deltacsmA), lacking one of the chitin synthase genes, were grown in shake flasks. Hyphae were immobilized on polylysine-coated coverslips and AFM force--displacement curves were collected. When grown in complete medium, wild-type hyphae had a cell wall spring constant of 0.29 +/- 0.02 N/m. When wild-type and mutant hyphae were grown in the same medium with added KCl (0.6 M), hyphae were significantly less rigid with spring constants of 0.17 +/- 0.01 and 0.18 +/- 0.02 N/m, respectively. Electron microscopy was used to measure the cell wall thickness and hyphal radius. By use of finite element analysis (FEMLAB v 3.0, Burlington, MA) to simulate AFM indentation, the elastic modulus of wild-type hyphae grown in complete medium was determined to be 110 +/- 10 MPa. This decreased to 64 +/- 4 MPa for hyphae grown in 0.6 M KCl, implying growth medium osmotic conditions have significant effects on cell wall elasticity. Mutant hyphae grown in KCl-supplemented medium were found to have an elastic modulus of 67 +/- 6 MPa. These values are comparable with other microbial systems (e.g., yeast and bacteria). It was also found that under these growth conditions axial variation in elastic modulus along fungal hyphae was small. To determine the relationship between composition and mechanical properties, cell wall composition was measured by anion-exchange liquid chromatography and pulsed electrochemical detection. Results show similar composition between wild-type and mutant strains. Together, these data imply differences in mechanical properties may be dependent on varying molecular structure of hyphal cell walls as opposed to wall composition.  相似文献   

18.
Determinations of the viscoelastic properties of extracellular matrices (ECMs) are becoming increasingly important for accurate predictive modeling of biological systems. Since the interactions of the cells with the ECM and surrounding fluid (e.g., blood, media) each affect cell behavior; it is advantageous to evaluate the ECM's material properties in the presence of the hydrating fluid. Conventional rheometry methods evaluate the bulk material properties of gel materials while displacing the hydrating liquid film. Such systems are therefore nonideal for testing materials such as ECMs, whose properties change with dehydration. The new patent pending, piezoelectrically actuated linear rheometer is designed to eliminate this problem. It uses a single cantilever to apply an oscillating load to the gel and to sense the gel's deflection. Composed of two thin film piezopolymer layers, the cantilever uses one layer as the actuator, and the second piezopolymer layer to measure the lateral movement of its attached probe. The viscoelastic nature of the ECM adds stiffness and damping to the system, resulting in the attenuation and phase shift of the sensor's output voltage. From these parameters, the ECM's shear storage and loss moduli are then determined. Initial tests on the BioMatrix I and type I collagen ECMs reveal that the first prototype of the piezoelectrically actuated linear rheometer is capable of accurately determining the trend and order of magnitude of an ECM's viscoelastic properties. In this paper, details of the rheometer's design and operating principles are described.  相似文献   

19.

In this study, we demonstrate the design of a photonic crystal fiber (PCF)-based plasmonic sensor to measure the glucose level of urine. The sensor is designed by placing a small segment of PCF between a lead-in and a lead-out single-mode fiber. We utilize the finite element method to simulate the proposed plasmonic sensor for the measurement of glucose level in urine. To offer external sensing, the cladding layer of the PCF was coated by a thin layer of gold where the gold-coated PCF was immersed in the urine sample. As a result, the urine can easily interact with the plasmonic layer of the sensor. In the outermost laser of the PCF, we considered a perfectly matched layer as a boundary condition. The simulation results confirm excellent wavelength and amplitude sensitivities where the maximum wavelength sensitivity was 2500 nm/RIU and amplitude sensitivity was 152 RIU?1 with a sensing resolution of 4?×?10?6. For optimization of the plasmonic sensor, we varied the physical parameters of the cladding air holes and the thickness of the gold layer during the simulation. We strongly believe that the proposed plasmonic sensor will play a significant role to pave the way for achieving a simple but effective PCF-based glucose sensor.

  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号