1.
Tissue engineering of blood vessel   总被引:4,自引:0,他引:4  
Vascular grafts are in large demand for coronary and peripheral bypass surgeries. Although synthetic grafts have been developed, replacement of vessels with purely synthetic polymeric conduits often leads to the failure of such graft, especially in the grafts less than 6 mm in diameter or in the areas of low blood flow, mainly due to the early formation of thrombosis. Moreover, the commonly used materials lack growth potential, and long-term results have revealed several material-related failures, such as stenosis, thromboembolization, calcium deposition and infection. Tissue engineering has become a promising approach for generating a bio-compatible vessel graft with growth potential. Since the first success of constructing blood vessels with collagen and cultured vascular cells by Weinberg and Bell, there has been considerable progress in the area of vessel engineering. To date, tissue- engineered blood vessels (TEBVs) could be successfully constructed in vitro, and be used to repair the vascular defects in animal models. This review describes the major progress in the field, including the seeding cell sources, the biodegradable scaffolds, the construction technologies, as well as the encouraging achievements in clinical applications. The remaining challenges are also discussed.  相似文献   

2.
We investigated the performance of small-caliber polyurethane (PU) small-diameter vascular prosthesis generated using the electrospinning technique. PU was electrospun into small-diameter, small-caliber tubular scaffolds for potential application as vascular grafts. We investigated the effects of electrospinning conditions (solution concentration, mandrel rotation speed) on the microstructure and porosity of the scaffolds for the purpose of preparing scaffolds with optimum microstructures and properties. We evaluated the mechanical properties of the scaffolds by tensile tests and the cytotoxicity of the PU small-diameter, small-caliber PU synthetic vascular graft by the MTT assay. The adhesion of endothelial cells to the PU scaffold was characterized by Hoechst staining and fluorescence microscopy, and we measured endothelial cell proliferation on the PU scaffold by the CCK-8 assay. We analyzed the prosthesis microstructure and endothelial cell morphology using scanning electron microscopy. With increasing PU concentration in the electrospinning solution, the fiber diameter of the vascular graft increased and the porosity decreased. In addition, with increasing electrospinning time, the wall thickness increased and the porosity decreased. We found that regular fiber orientation can be obtained by adjusting the rotation speed of the mandrel. Cell proliferation was not inhibited as the small-caliber PU synthetic vascular grafts showed little cytotoxicity. The endothelial cells had faster adherence to the PU scaffolds than to the PTFE surface during the initial contact. After prolonged cell culture, significantly higher endothelial cell proliferation rate was observed in the PU scaffold groups than the PTFE group. We obtained small-caliber PU vascular grafts with optimal fiber arrangement, excellent mechanical properties, and optimal biocompatibility by optimizing the electrospinning conditions. This study provides in vitro biocompatibility data that is helpful for the clinical application of the PU small-diameter, small-caliber PU vascular grafts.  相似文献   

3.
Nitric oxide-producing polyurethanes   总被引:2,自引:0,他引:2  
Thrombus formation and eventual intimal hyperplasia are the leading causes of small-diameter synthetic vascular graft failure. To combat these issues, we have incorporated a diazeniumdiolate-modified nitric oxide (NO)-producing peptide into a polyurethane to improve the thromboresistance of this biocompatible polymer. NO production by polyurethane films occurred for approximately 2 months under physiological conditions, and mechanical properties of the material were suitable for vascular graft applications. Platelet adhesion to NO-releasing polyurethane was dramatically decreased compared to control polyurethane. Furthermore, endothelial cell growth was stimulated in the presence of the NO-releasing polyurethane, while smooth muscle cell growth was greatly inhibited. The ability of this bioactive material to inhibit platelet adhesion and smooth muscle cell proliferation while encouraging endothelialization suggests that this NO-generating polyurethane may be suitable as a candidate material for small-diameter vascular grafts.  相似文献   

4.
Cardiovascular disease is one of the leading cause of mortality in the US and especially, coronary artery disease increases with an aging population and increasing obesity1. Currently, bypass surgery using autologous vessels, allografts, and synthetic grafts are known as a commonly used for arterial substitutes2. However, these grafts have limited applications when an inner diameter of arteries is less than 6 mm due to low availability, thrombotic complications, compliance mismatch, and late intimal hyperplasia3,4. To overcome these limitations, tissue engineering has been successfully applied as a promising alternative to develop small-diameter arterial constructs that are nonthrombogenic, robust, and compliant. Several previous studies have developed small-diameter arterial constructs with tri-lamellar structure, excellent mechanical properties and burst pressure comparable to native arteries5,6. While high tensile strength and burst pressure by increasing collagen production from a rigid material or cell sheet scaffold, these constructs still had low elastin production and compliance, which is a major problem to cause graft failure after implantation. Considering these issues, we hypothesized that an elastometric biomaterial combined with mechanical conditioning would provide elasticity and conduct mechanical signals more efficiently to vascular cells, which increase extracellular matrix production and support cellular orientation.The objective of this report is to introduce a fabrication technique of porous tubular scaffolds and a dynamic mechanical conditioning for applying them to arterial tissue engineering. We used a biodegradable elastomer, poly (glycerol sebacate) (PGS)7 for fabricating porous tubular scaffolds from the salt fusion method. Adult primary baboon smooth muscle cells (SMCs) were seeded on the lumen of scaffolds, which cultured in our designed pulsatile flow bioreactor for 3 weeks. PGS scaffolds had consistent thickness and randomly distributed macro- and micro-pores. Mechanical conditioning from pulsatile flow bioreactor supported SMC orientation and enhanced ECM production in scaffolds. These results suggest that elastomeric scaffolds and mechanical conditioning of bioreactor culture may be a promising method for arterial tissue engineering.  相似文献   

5.
Small-intestine submucosa (SIS) is cell-free, 100-mu-thick collagen derived from the small intestine. It has been used as a vascular graft and has the highly desirable ability to be remodeled to become histologically indistinguishable from native adjacent artery. To date there has been limited reporting of its preimplantation and explant mechanical properties as a vascular graft. In this study, compliance, elastic modulus, and burst pressure were measured on preimplant-tested 5- and 8-mm SIS grafts and two 60-day remodeled grafts. Seven prefabricated grafts were implanted in the carotid (n = 7) in dogs, which were sacrificed after 55-63 days. The animals (n = 4) weighed from 22 to 27 kg. One dog received a unilateral carotid graft, and 3 dogs received bilateral carotid grafts. The fabrication technique employed hand-suturing with either nonresorbable or resorbable sutures. None of the grafts had a patency failure. Angiograms taken at 1 month and just before explantation showed uniform flow and no dilation. At the time of explantation, all carotid grafts were found to be encased in fibrous tissue. The grafts made with nonresorbable sutures showed thicker tissue growth at the suture line compared with those made with the resorbable sutures. Along the suture line, the grafts made with resorbable sutures exhibited a more natural color than those sutured with nonresorbable sutures. When the explanted carotid grafts were slit open, the lumen was white, shiny, and glistening. The grafts sutured with nonresorbable sutures exhibited small areas of fibrin and red blood cells when the suture was within the lumen. The resorbable-sutured grafts did not exhibit this response. The mean compliance (percent diameter increase for a pressure rise from 80 to 120 mm Hg) was on average 4.6% (range, 2.9%-8.6%) for the 5-mm preimplant-tested grafts. For the 8-mm preimplant-tested grafts, the increase in diameter for the same pressure rise was 8.7%, on average (range, 7.2% to 9.5%). For comparison, the small-diameter SIS graft at the time of implantation was about one half as compliant as the adjacent dog carotid artery, about 4 times more compliant than a typical vein graft, and more than 10 times more compliant than synthetic vascular grafts. The compliance measured on two 60-day carotid grafts was 10.5% and 7.2%, respectively. This is midway between the original compliance value and the compliance of a typical canine carotid artery (14%), indicating that mechanical remodeling occurred. The modulus of elasticity (E) increased exponentially with increasing pressure according to E = E0e alpha P, where E0 is the zero-pressure modulus and alpha is the exponent that describes the rate of increase in E with pressure; the unit of measure for variables E, E0, and P is g/cm2. The mean value for E0 was 4106 gm/cm2 (range, 1348-5601). The mean value for alpha was 0.0059 (range, 0.0028-0.0125). At 100 mm Hg, the mean value for E was 8.03 x 10(6) dynes/cm2 (range, 4.95-15.7 x 10(6)). For a 60-day SIS graft implant, the elastic modulus at 100 mm Hg decreased from a high value at implant time to twice that of a typical native canine carotid artery. The mean burst pressure for 5.5-mm grafts was 3517 mm Hg (range, 2069-4654). The burst pressure of the remodeled carotid grafts averaged 5660 mm Hg. The burst pressure for a typical carotid artery is about 5000 mm Hg. The results of this preliminary study complement those of previous SIS-vascular-graft studies and add a new factor, namely that the mechanical properties of the remodeled graft approach those of the vessel it replaces.  相似文献   

6.
Vascular surgeries such as coronary artery bypass require small diameter vascular grafts with properties that are not available at this time. Approaches using synthetic biomaterials have been not completely successful in producing non-thrombogenic grafts with inner diameters less than 6 mm, and there is a need for new biomaterials and graft designs. We propose silk fibroin as a microvascular graft material and describe tubular silk scaffolds that demonstrate improved properties over existing vascular graft materials. Silk tubes produced using an aqueous gel spinning technique were first assessed in vitro in terms of thrombogenicity (thrombin and fibrinogen adsorption, platelet adhesion) and vascular cell responses (endothelial and smooth muscle cell attachment and proliferation) in comparison with polytetrafluoroethylene (PTFE), a synthetic material most frequently used for vascular grafts. Silk tubes were then implanted into the abdominal aortas of Sprague-Dawley rats. At time points of 2 weeks and 4 weeks post implantation, tissue outcomes were assessed through gross observation (acute thrombosis, patency) and histological staining (H&E, Factor VIII, smooth muscle actin). Over the 4-week time period, we observed graft patency and endothelial cell lining of the lumen surfaces. These results demonstrate the feasibility of using silk fibroin as a vascular graft material and some advantages of silk tubes over the currently used synthetic grafts.  相似文献   

7.
In the field of arterial vascular reconstructions there is an increasing need for functional small-diameter artificial grafts (inner diameter < 6mm). When autologous replacement vessels are not available, for example because of the bad condition of the vascular system in the patient, the surgeon has no other alternative than to implant a synthetic polymer-based vessel. After implantation the initial major problem concerning these vessels is the almost immediate occlusion, due to blood coagulation and platelet deposition, under the relatively low flow conditions. As the search for the perfect bio-inert polymer has not revealed a material with suitable properties for this application, improved performance of small-diameter artificial blood vessels is now being sought in the biological field. The poor blood-compatibility of an artificial vascular graft is not simply because of its coagulation-stimulating or platelet-activating properties, but more due to its inability to actively participate in the prevention of blood coagulation and platelet deposition. As these functions are naturally performed by endothelial cells, the utilization of these cells seems inevitable for the construction of a functional small-diameter artificial blood vessels. This review describes the current status of the use of endothelial cells to improve the performance of artificial vascular prostheses.  相似文献   

8.
Conventionally used vascular grafts such as polyester (Dacron) or expanded polytetrafluoroethylene perform inadequately as small-diameter vascular bypass grafts (SDBGs). SDBGs, which can maintain long-term patency and those that could potentially evolve with the somatic growth, are highly desirable in vascular surgery and thus research into tissue-engineered blood vessels (TEBVs) is of keen interest. A TEBV was developed by seeding endothelial cells onto a collagen matrix that was cross-linked and contracted by smooth muscle cells (SMCs). A polyester graft served as a scaffold. Recovery studies (12 TEBVs and seven controls) were carried out to assess in vivo endothelialization and long-term patency of TEBVs. Hemodynamic observations indicated para-anastomotic turbulences and high shear stress at anastomosis. Recovery studies demonstrated confluent endothelialization, thrombus-free surfaces, and patent TEBVs in all cases. Graft incorporation and neovascularization of the scaffold occurred in both hybrid and control grafts. However, thickened neointima formation occurred in TEBV grafts, which was most likely caused by the rigidity of polyester scaffold. Significant perigraft inflammatory changes could be observed in both TEBVs and control grafts at 1, 4, and 8 weeks. In conclusion, the TEBVs demonstrated satisfactory performance as an infra-renal-aortic graft in a porcine model. The TEBV serves as a promising model and facilitates the development of a TEBV in a clinical setting, potentially with human stem cells and with more biocompatible, biodegradable scaffolds that are mechanically more compliant with natural vessels.  相似文献   

9.
Arterial conduits are increasingly preferred for surgical bypass because of inherent functional properties conferred by arterial endothelial cells, especially nitric oxide production in response to physiologic stimuli. Here we tested whether endothelial progenitor cells (EPCs) can replace arterial endothelial cells and promote patency in tissue-engineered small-diameter blood vessels (4 mm). We isolated EPCs from peripheral blood of sheep, expanded them ex vivo and then seeded them on decellularized porcine iliac vessels. EPC-seeded grafts remained patent for 130 days as a carotid interposition graft in sheep, whereas non-seeded grafts occluded within 15 days. The EPC-explanted grafts exhibited contractile activity and nitric-oxide-mediated vascular relaxation that were similar to native carotid arteries. These results indicate that EPCs can function similarly to arterial endothelial cells and thereby confer longer vascular-graft survival. Due to their unique properties, EPCs might have other general applications for tissue-engineered structures and in treating vascular diseases.  相似文献   

10.
The study provides a pathway to design a mechanics-matching vascular graft for an end-to-end anastomosis to a host artery. For functional equivalence, we submit that the graft and a host artery should have equal inner deformed diameters, equal pressure-radius module, and experience equal axial forces when subjected to mean arterial pressure. These criteria for mechanical equivalence are valid for a large class of materials that can be considered as elastic incompressible and orthotropic solids. As an example, specific known artery properties were used to design or select a graft made from a new synthetic biomaterial to demonstrate that reliable and robust technology for graft fabrication is possible.  相似文献   

11.
Smooth muscle cells (SMCs) from prosthetic vascular grafts constitutively secrete higher levels of collagen than aortic SMCs. Lipid oxidation products accumulate in grafts, and we postulated that they stimulate SMC production of collagen. The effect of oxidized low-density lipoprotein (oxLDL) on type I collagen secretion by aortic and graft SMCs was compared. SMCs isolated from the canine thoracic aorta or Dacron thoracoabdominal grafts (n = 10) were incubated with native LDL or oxLDL (0-400 microg cholesterol/ml) for 72 h. Type I collagen in the conditioned medium was measured by ELISA. OxLDL increased collagen production by graft SMCs from 4.1 +/- 0.3 to 11.0 +/- 0.4 ng/microg DNA and by aortic SMCs from 2.3 +/- 0.1 to 3.5 +/- 0.2 ng/microg DNA. Native LDL had little effect. LY-83583, a superoxide generator, stimulated a dramatic increase in collagen secretion by graft SMCs and a smaller but significant elevation by aortic SMCs. OxLDL has been shown to increase PDGF production by graft SMCs, and PDGF can stimulate collagen production. Anti-PDGF antibody inhibited the increase in collagen production by graft SMCs that was stimulated by oxLDL, implicating PDGF as one mechanism of oxLDL-induced collagen production. Lipid oxidation products that accumulate in prosthetic vascular grafts can cause an oxidative stress that stimulates PDGF production by graft SMCs that in turn stimulates collagen production, contributing to the progression of intimal hyperplasia.  相似文献   

12.
For years intensive research has been done to improve the hemocompatibility of blood contacting vascular devices. Despite the enormous progress in physicochemical surface optimization technologies, the native endothelium still represents the ideal surface for blood contact. Numerous tissue engineering strategies aspired towards the endothelialization of graft surfaces to generate a non-thrombogenic barrier on artificial materials. A paradigm change in surface modification concepts is the in vivo endothelialization of vascular grafts by capturing circulating endothelial progenitor cells (EPCs) directly from the blood stream via biofunctionalized implant materials. Thereby, capture molecules are immobilized on artificial vascular grafts to mimic a pro-homing substrate for EPCs. In this review, different coating strategies for in vivo capturing of EPCs on synthetic implants are discussed. This therapeutic concept opens a new chapter in regenerative medicine by realizing the vision that every patient seeds his implants with his own progenitor cells to make the synthetic grafts unrecognizable for the body's rejection mechanisms.  相似文献   

13.
随着人口老龄化问题的日益严重以及心血管疾病患病的增加,临床上对血管移植物的需求量也逐渐增大。利用涤纶和聚四氟乙烯制备大直径血管(>6mm)在临床上得到了广泛的应用,而小直径(< 6 mm)血管常因血栓和感染导致移植的失败,因此构建内皮细胞贴附的组织工程血管就显得至关重要。通过合成RGD修饰的海藻酸钠(RGD-alginate, RGD-ALG)以及甲基丙烯酸化的明胶(methacrylated gelatin,GelMA),利用氯化钙溶液溶解的普朗尼克F127作为牺牲材料,利用同轴打印制备出组织工程血管。通过选择不同直径的同轴打印喷嘴以及调节打印参数,可以制备出不同直径的组织工程血管。制备出的组织工程血管可以承受人生理状态下的血管压力,可以进行稳定的灌流培养,并且人脐静脉血管内皮细胞在通入组织工程血管中后可以稳定贴附在管壁上。  相似文献   

14.
For the treatment of vascular disease, the major cause of death in Western society, there is an urgent need for tissue-engineered, biocompatible, small calibre artery substitutes that restore biological function. Vascular tissue engineering of such grafts involves the development of compliant synthetic or biomaterial scaffolds that incorporate vascular cells and extracellular matrix. Elastic fibres are major structural elements of arterial walls that can enhance vascular graft design and patency. In blood vessels, they endow vessels with the critical property of elastic recoil. They also influence vascular cell behaviour through direct interactions and by regulating growth factor activation. This review addresses physiological elastic fibre assembly and contributions to vessel structure and function, and how elastic fibre biology is now being exploited in small diameter vascular graft design.  相似文献   

15.
The higher patency rates of cardiovascular implants, including vascular bypass grafts, stents, and heart valves are related to their ability to inhibit thrombosis, intimal hyperplasia, and calcification. In native tissue, the endothelium plays a major role in inhibiting these processes. Various bioengineering research strategies thereby aspire to induce endothelialization of graft surfaces either prior to implantation or by accelerating in situ graft endothelialization. This article reviews potential bioresponsive molecular components that can be incorporated into (and/or released from) biomaterial surfaces to obtain accelerated in situ endothelialization of vascular grafts. These molecules could promote in situ endothelialization by the mobilization of endothelial progenitor cells (EPC) from the bone marrow, encouraging cell-specific adhesion (endothelial cells (EC) and/or EPC) to the graft and, once attached, by controlling the proliferation and differentiation of these cells. EC and EPC interactions with the extracellular matrix continue to be a principal source of inspiration for material biofunctionalization, and therefore, the latest developments in understanding these interactions will be discussed.  相似文献   

16.
The surgical repair of heart and vascular disease often requires implanting synthetic grafts. While synthetic grafts have been successfully used for medium-to-large sized arteries, applications for small diameter arteries (<6 mm) is limited due to high rates of occlusion by thrombosis. Our objective was to develop a tissue engineered vascular graft (TEVG) for small diameter arteries. TEVGs composed of polylactic acid nanofibers with inner luminal diameter between 0.5 and 0.6 mm were surgically implanted as infra-renal aortic interposition conduits in 25 female C17SCID/bg mice. Twelve mice were given sham operations. Survival of mice with TEVG grafts was 91.6% at 12 months post-implantation (sham group: 83.3%). No instances of graft stenosis or aneurysmal dilatation were observed over 12 months post-implantation, assessed by Doppler ultrasound and microCT. Histologic analysis of explanted TEVG grafts showed presence of CD31-positive endothelial monolayer and F4/80-positive macrophages after 4, 8, and 12 months in vivo. Cells positive for α-smooth muscle actin were observed within TEVG, demonstrating presence of smooth muscle cells (SMCs). Neo-extracellular matrix consisting mostly of collagen types I and III were observed at 12 months post-implantation. PCR analysis supports histological observations. TEVG group showed significant increases in expressions of SMC marker, collagen-I and III, matrix metalloproteinases-2 and 9, and itgam (a macrophage marker), when compared to sham group. Overall, patency rates were excellent at 12 months after implantation, as structural integrity of these TEVG. Tissue analysis also demonstrated vessel remodeling by autologous cell.  相似文献   

17.
L Song  Q Zhou  P Duan  P Guo  D Li  Y Xu  S Li  F Luo  Z Zhang 《PloS one》2012,7(8):e42569
Small-diameter (<4 mm) vascular constructs are urgently needed for patients requiring replacement of their peripheral vessels. However, successful development of constructs remains a significant challenge. In this study, we successfully developed small-diameter vascular constructs with high patency using our integrally designed computer-controlled bioreactor system. This computer-controlled bioreactor system can confer physiological mechanical stimuli and fluid flow similar to physiological stimuli to the cultured grafts. The medium circulating system optimizes the culture conditions by maintaining fixed concentration of O(2) and CO(2) in the medium flow and constant delivery of nutrients and waste metabolites, as well as eliminates the complicated replacement of culture medium in traditional vascular tissue engineering. Biochemical and mechanical assay of newly developed grafts confirm the feasibility of the bioreactor system for small-diameter vascular engineering. Furthermore, the computer-controlled bioreactor is superior for cultured cell proliferation compared with the traditional non-computer-controlled bioreactor. Specifically, our novel bioreactor system may be a potential alternative for tissue engineering of large-scale small-diameter vascular vessels for clinical use.  相似文献   

18.

Background

Coronary bypass graft failure as a result of acute thrombosis and intimal hyperplasia has been the major challenge in surgical procedures involving small-diameter vascular prosthesis. Coating synthetic grafts with patients'' own endothelial cells has been suggested to improve the patency rate and overall success of bypass surgeries.

Methodology/Principal Findings

We isolated endothelial progenitor cells (EPCs) from leftover pieces of human saphenous vein/mammary artery. We demonstrate that EPCs can be expanded to generate millions of cells under low-density culture conditions. Exposure to high-density conditions induces differentiation to endothelial cell phenotype. EPC–derived endothelial cells show expression of CD144high, CD31, and vWF. We then assessed the ability of differentiated endothelial cells to adhere and grow on small diameter expanded polytetrafluoroethylene (ePTFE) tubings. Since ePTFE tubings are highly hydrophobic, we optimized protocols to introduce hydrophilic groups on luminal surface of ePTFE tubings. We demonstrate here a stepwise protocol that involves introduction of hydrophilic moieties and coating with defined ECM components that support adhesion of endothelial cells, but not of blood platelets.

Conclusion/Significance

Our data confirms that endothelial progenitors obtained from adult human blood vessels can be expanded in vitro under xenoprotein-free conditions, for potential use in endothelialization of small diameter ePTFE grafts. These endothelialized grafts may represent a promising treatment strategy for improving the clinical outcome of small-caliber vascular grafts in cardiac bypass surgeries.  相似文献   

19.
Bacterial cellulose (BC) has received substantial interest owing to its unique structural features and impressive physico-mechanical properties. BC has a variety of applications in biomedical fields, including use as biomaterial for artificial skin, artificial blood vessels, vascular grafts, scaffolds for tissue engineering, and wound dressing. However, pristine BC lacks certain properties, which limits its applications in various fields; therefore, synthesis of BC composites has been conducted to address these limitations. A variety of BC composite synthetic strategies have been developed based on the nature and relevant applications of the combined materials. BC composites are primarily synthesized through in situ addition of reinforcement materials to BC synthetic media or the ex situ penetration of such materials into BC microfibrils. Polymer blending and solution mixing are less frequently used synthetic approaches. BC composites have been synthesized using numerous materials ranging from organic polymers to inorganic nanoparticles. In medical fields, these composites are used for tissue regeneration, healing of deep wounds, enzyme immobilization, and synthesis of medical devices that could replace cardiovascular and other connective tissues. Various electrical products, including biosensors, biocatalysts, E-papers, display devices, electrical instruments, and optoelectronic devices, are prepared from BC composites with conductive materials. In this review, we compiled various synthetic approaches for BC composite synthesis, classes of BC composites, and applications of BC composites. This study will increase interest in BC composites and the development of new ideas in this field.  相似文献   

20.
Rebuilding tissues involves the creation of a vasculature to supply nutrients and this in turn means that the endothelial cells (ECs) of the resulting endothelium must be a quiescent non-thrombogenic blood contacting surface. Such ECs are deployed on biomaterials that are composed of natural materials such as extracellular matrix proteins or synthetic polymers in the form of vascular grafts or tissue-engineered constructs. Because EC function is influenced by their origin, biomaterial surface chemistry and hemodynamics, these issues must be considered to optimize implant performance. In this review, we examine the recent in vivo use of endothelialized biomaterials and discuss the fundamental issues that must be considered when engineering functional vasculature.  相似文献   