首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.

Purpose

To investigate whether corneal thickness parameters measured by optical coherence tomography (OCT), such as central corneal thickness (CCT), central corneal stromal thickness (CCST), and central corneal epithelial thickness (CCET), influence the intraocular pressure (IOP) difference measured by Goldmann applanation tonometry (GAT) and non-contact tonometry (NCT).

Methods

In total, 50 eyes from 50 subjects without glaucomatous defects were included in this retrospective, cross-sectional study. We measured IOP using GAT and NCT and calculated the difference between the two methods. CCT was measured by a Cirrus HD-OCT device using anterior segment imaging. The basement membrane of the epithelium, which was seen as a high-reflection line in the OCT image, was taken as a reference line to measure CCST and CCET.

Results

The mean IOP measured by GAT and NCT was 16.7 ± 3.0 and 18.1 ± 3.8 mmHg, respectively. The mean IOP difference was 1.5 ± 1.7 mmHg, and the IOP measured by NCT was 8.4% ± 11.3% higher than that measured by GAT. The CCET and CCST were 57.9 ± 5.6 and 501.7 ± 33.8 μm, respectively. CCT showed a positive correlation with both GAT IOP (r = 0.648, P < 0.001) and NCT IOP (r = 0.676, P < 0.001). Although CCST showed a significant correlation with GAT IOP and NCT IOP, CCET did not. The difference between GAT IOP and NCT IOP increased with CCT (r = 0.333, P = 0.018), and CCET was positively correlated with the IOP difference between GAT and NCT (r = 0.435, P = 0.002).

Conclusions

IOP increased with greater CCT, and CCST seemed to have a more important role than CCET. CCET also increased with greater CCT, and this may be a possible explanation for the increasing difference in IOP between GAT and NCT with increasing CCT.  相似文献   

2.
Corneal thickness (CT) maps of the central (2-mm diameter), para-central (2 to 5-mm diameter), peripheral (5 to 6-mm diameter), and minimum (5-mm diameter) cornea were measured in normal Chinese school children aged 7 to 15 years old using Fourier-domain optical coherence tomography. Multiple regression analyses were performed to explore the effect of associated factors [age, gender, refraction, axial length and corneal curvature radius (CCR)] on CT and the relationship between central corneal thickness (CCT) and intraocular pressure (IOP). A total of 1228 eyes from 614 children were analyzed. The average CCT was 532.96 ± 28.33 μm for right eyes and 532.70 ±28.45 μm for left eyes. With a 10 μm increase in CCT, the IOP was elevated by 0.37 mm Hg, as measured by noncontact tonometry. The CT increased gradually from the center to the periphery. The superior and superior nasal regions had the thickest CTs, while the thinnest points were primarily located in the inferior temporal cornea. The CCT was associated with CCR (p = 0.008) but not with gender (p = 0.075), age (p = 0.286), axial length (p = 0.405), or refraction (p = 0.985). In the para-central region and the peripheral cornea, increased CT was associated with younger age, male gender, and a flatter cornea.  相似文献   

3.

Purpose

To determine the distributions and relation of central corneal thickness (CCT) and intraocular pressure (IOP) by NT-530P in Chinese juveniles, and the effect of gender, age, height, weight and refractive errors on the CTT and IOP.

Methods

CCT and IOP of 982 eyes in 514 juveniles aged from 7 to 18 years were measured with NT-530P. Multi-linear regression and ANOVA analysis were used to analyze the relation of CCT and IOP, and the effect of gender, age, height, weight, refractive condition on CCT and IOP respectively.

Results

The mean CCT and IOP were 554.19±35.46 µm and 15.31±2.57 mmHg. There were significant correlations between the CCT and IOP values. Linear regression analysis revealed a positive correlation between CCT and IOP (r = 0.44, P<0.05). Linear regression equation: IOP = −2.35+0.032CCT, which means the IOP will increase 0.32 mm Hg for every 10-µm increase in CCT. The mean of Corrected IOP (CIOP) was 15.32±2.38 mmHg and had no relation with CCT. There was a negative correlation between refraction degree and CCT (P<0.05), but no correlation between refraction degree and IOP. Multi-linear regression model revealed that the height, weight, age and gender have no effect on the distribution of CCT and IOP respectively.

Conclusions

There is a 0.32 mmHg increase in IOP for every 10-µm increase in CCT. The height, weight, age and gender has no effect on the distribution of CCT and IOP. CCT will become thinner with myopia diopters increases in juveniles. The measurement of CCT is helpful in evaluating the actual IOP correctly.  相似文献   

4.
Fuchs endothelial corneal dystrophy (FECD) is the most common late-onset, vision-threatening corneal dystrophy in the United States, affecting about 4% of the population. Advanced FECD involves a thickening of the cornea from stromal edema and changes in Descemet membrane. To understand the relationship between FECD and central corneal thickness (CCT), we characterized common genetic variation in COL8A2 and TCF4, genes previously implicated in CCT and/or FECD. Other genes previously associated with FECD (PITX2, ZEB1, SLC4A11), and genes only known to affect CCT (COL5A1, FOXO1, AVGR8, ZNF469) were also interrogated. FECD probands, relatives and controls were recruited from 32 clinical sites; a total of 532 cases and 204 controls were genotyped and tested for association of FECD case/control status, a 7-step FECD severity scale and CCT, adjusting for age and sex. Association of FECD grade with TCF4 was highly significant (OR  = 6.01 at rs613872; p = 4.8×10−25), and remained significant when adjusted for changes in CCT (OR  = 4.84; p = 2.2×10−16). Association of CCT with TCF4 was also significant (p = 6.1×10−7), but was abolished with adjustment for FECD grade (p = 0.92). After adjusting for FECD grade, markers in other genes examined were modestly associated (p ∼ 0.001) with FECD and/or CCT. Thus, common variants in TCF4 appear to influence FECD directly, and CCT secondarily via FECD. Additionally, changes in corneal thickness due to the effect of other loci may modify disease severity, age-at-onset, or other biomechanical characteristics.  相似文献   

5.

Main objective

To evaluate the distribution of central corneal thickness (CCT) in a large German cohort and to analyse its relationship with intraocular pressure and further ocular factors.

Design

Population-based, prospective, cohort study.

Methods

The Gutenberg Health Study (GHS) cohort included 4,698 eligible enrollees of 5,000 subjects (age range 35–74 years) who participated in the survey from 2007 to 2008. All participants underwent an ophthalmological examination including slitlamp biomicroscopy, intraocular pressure measurement, central corneal thickness measurement, fundus examination, and were given a questionnaire regarding glaucoma history. Furthermore, all subjects underwent fundus photography and visual field testing using frequency doubling perimetry.

Results

Mean CCT was 557.3±34.3 µm (male) and 551.6±35.2 µm in female subjects (Mean CCT from right and left eyes). Younger male participants (35–44 years) presented slightly thicker CCT than those older. We noted a significant CCT difference of 4 µm between right and left eyes, but a high correlation between eyes (Wilcoxon test for related samples: p<0.0001). Univariable linear regression stratified by gender showed that IOP was correlated with CCT (p<0.0001). A 10 µm increase in CCT led to an increase in IOP between 0.35–0.38 mm Hg, depending on the eye and gender. Multivariable linear regression analysis revealed correlations between gender, spherical equivalent (right eyes), and CCT (p<.0001 and p = 0.03, respectively).

Conclusions

We observed positive correlations between CCT and IOP and gender. CCT was not correlated with age, contact lens wear, positive family history for glaucoma, lens status, or iris colour.  相似文献   

6.

Purpose

To determine the measurement reliability of CorVis ST, a dynamic Scheimpflug analyser, in virgin and post-photorefractive keratectomy (PRK) eyes and compare the results between these two groups.

Methods

Forty virgin eyes and 42 post-PRK eyes underwent CorVis ST measurements performed by two technicians. Repeatability was evaluated by comparing three consecutive measurements by technician A. Reproducibility was determined by comparing the first measurement by technician A with one performed by technician B. Intraobserver and interobserver intraclass correlation coefficients (ICCs) were calculated. Univariate analysis of covariance (ANCOVA) was used to compare measured parameters between virgin and post-PRK eyes.

Results

The intraocular pressure (IOP), central corneal thickness (CCT) and 1st applanation time demonstrated good intraobserver repeatability and interobserver reproducibility (ICC≧0.90) in virgin and post-PRK eyes. The deformation amplitude showed a good or close to good repeatability and reproducibility in both groups (ICC≧0.88). The CCT correlated positively with 1st applanation time (r = 0.437 and 0.483, respectively, p<0.05) and negatively with deformation amplitude (r = −0.384 and −0.375, respectively, p<0.05) in both groups. Compared to post-PRK eyes, virgin eyes showed longer 1st applanation time (7.29±0.21 vs. 6.96±0.17 ms, p<0.05) and lower deformation amplitude (1.06±0.07 vs. 1.17±0.08 mm, p<0.05).

Conclusions

CorVis ST demonstrated reliable measurements for CCT, IOP, and 1st applanation time, as well as relatively reliable measurement for deformation amplitude in both virgin and post-PRK eyes. There were differences in 1st applanation time and deformation amplitude between virgin and post-PRK eyes, which may reflect corneal biomechanical changes occurring after the surgery in the latter.  相似文献   

7.

Purpose

To describe the ethnic differences in central corneal thickness (CCT) in population-based samples of ethnic Bai, Yi and Han people living in rural China.

Methods

6504 adults (2119 ethnic Bai, 2202 ethnic Yi and 2183 ethnic Han) aged 50 years or older participated in the study. Each subject underwent standardized ocular examinations and interviewer-administered questionnaires for risk factor assessment. CCT was measured for both eyes using an ultrasound pachymeter. Regression and principal component analysis were performed to examine the relationship of ethnicity and other factors with CCT.

Results

The mean CCT readings were 536.4 ± 34.2 μm in ethnic Bai, 532.1 ± 32.1 μm in ethnic Yi and 529.6 ± 32.7 μm in ethnic Han adults (P<0.001), respectively. There was a decreasing trend of mean CCT with increasing age across all ethnic groups. In multivariate linear regression models, increasing CCT was associated with younger age (P<0.001), male gender (P<0.001), Bai (P<0.001) or Yi (P<0.001) ethnicity, greater body mass index (P<0.001), higher systolic blood pressure (P<0.001), greater corneal curvature (P<0.001), deeper anterior chamber (P < 0.001), and thicker lens (P<0.001). Ethnicity contributed significantly to presence of thin cornea (60%; P< 0.001) compared with other factors. CCT had similar impact on intraocular pressure readings across all ethnic groups.

Conclusions

This study of more than 6500 multiethnic participants demonstrates significant ethnic variations in CCT, with Han ethnicity having the thinnest cornea compared with ethnic minorities. These data are essential to guide future multiethnic clinical trials on CCT-related ocular conditions such as glaucoma.  相似文献   

8.
PurposeTo study age-related changes in corneal deformation response to air-puff applanation tonometry.MethodsFifty healthy subjects were recruited for a prospective study and divided into two equal age groups (≤ 28 and ≥ 50 years old). Up to three measurements by a corneal deformation analyser based on the Scheimpflug principle were performed on the left eye of each subject. Raw Scheimpflug images were used to extract changes in anterior and posterior corneal profiles, which were further modelled by an orthogonal series of Chebyshev polynomial functions. Time series of the polynomial coefficients of even order exhibited a dynamic behavior in which three distinct stages were recognized. A bilinear function was used to model the first and the third stage of corneal dynamics. Slope parameters of the bilinear fit were then tested between the two age groups using Wilcoxon rank sum test and two-way non-parametric ANOVA (Friedman) test.ResultsStatistically significant changes (Wilcoxon test, P<0.05) between the age groups were observed in the phase of the second applanation dynamics for the posterior corneal profile. In a two-way comparison, in which the corneal profile was used as a dependent variable, statistically significant changes (ANOVA/Friedman test, P = 0.017) between the groups were also observed for that phase.ConclusionCorneal biomechanics depend on age. The changes in corneal deformation dynamics, which correspond to mostly free return of the cornea to its original shape after the air pulse, indicate that the age related differences in corneal biomechanics are subtle but observable with high speed imaging.  相似文献   

9.

Purpose

To examine characteristics of ocular hypertensive subjects and potential associations with estimated cerebrospinal fluid pressure (estCSFP).

Methods

The population-based Beijing Eye Study 2011 included 3468 individuals with a mean age of 64.6±9.8 years. Ocular hypertension was defined as intraocular pressure (IOP) >21 mmHg, normal optic nerve head appearance and normal retinal nerve fiber layer thickness. IOP was corrected for its dependence on central corneal thickness (CCT) and corneal curvature radius. Estimated CSFP was calculated as CSFP [mmHg] = 0.44×Body Mass Index [kg/m2]+0.16×Diastolic Blood Pressure [mmHg]−0.18×Age [Years]−1.91. Estimated trans-lamina cribrosa pressure difference (estTLCPD) was IOP–estCSFP.

Results

EstCSFP (10.5±3.6 mmHg versus 9.0±3.7 mmHg; P = 0.003) and estTLCPD (12.0±4.4 mmHg versus 5.4±3.8 mmHg; P<0.001) were higher in the ocular hypertensive group than in the normotensive group. In binary regression analysis, ocular hypertension was associated with increased estCSFP (P = 0.03; odds ratio (OR): 1.08; 95% confidence interval (CI): 1.01, 1.17) after adjusting for prevalence of arterial hypertension (P = 0.07; OR: 1.79; 95%CI: 0.96, 3.34), retinal nerve fiber layer thickness (P = 0.03; OR: 0.97; 95%CI: 0.95, 0.997) and blood glucose concentration (P = 0.006; OR: 1.17; 95%CI: 1.04, 1.30).

Conclusions

Ocular hypertensive subjects (with IOP correction for CCT and corneal curvature) as compared to ocular normotensive subjects had a significantly higher estCSFP in univariate analysis and in multivariate analysis. Despite of a higher estCSFP, estTLCPD was still markedly higher in ocular hypertensive eyes than in ocular normotensive eyes.  相似文献   

10.

Purpose

To assess the intraocular pressure (IOP) and its association in children in a population living in an oasis in the Gobi Desert.

Methods

The cross-sectional school-based study included all schools in the Ejina region. The children underwent an ophthalmic examination, non-contact tonometry and measurement of blood pressure and body height and weight.

Results

Out of eligible 1911 children, 1565 (81.9%) children with a mean age of 11.9±3.5 years (range: 6–21 years) participated. Mean spherical refractive error was −1.58±2.00 diopters. In multivariate analysis, higher IOP (right eye) was associated with younger age (P<0.001; standardized coefficient beta: −0.13; regression coefficient B: −0.13; 95% Confidence interval (CI):−0.18, −0.07), higher diastolic blood pressure (P<0.001;beta:0.13;B:0.05;95%CI:0.03,0.07), higher corneal refractive power (P<0.001;beta:0.11;B:0.23;95%CI:0.12,0.34), more myopic refractive error (P = 0.035;beta: −0.06;B: −0.10;95%CI: −0.19, −0.001), and Han Chinese ethnicity of the father (P = 0.03;beta:0.06;B:0.42;95%CI:0.04,0.89). If age and diastolic blood pressure were dropped, higher IOP was associated with higher estimated cerebrospinal fluid pressure (CSFP) (P<0.001;beta:0.09; B:0.13;95%CI:0.06,0.21) after adjusting for higher corneal refractive power (P<0.001) and Han Chinese ethnicity of the father (P = 0.04). Correspondingly, higher IOP of the left eye was associated with younger age (P<0.001;beta: −0.15;B: −0.16;95%CI: −0.21, −0.10), female gender (P<0.001;beta:0.09;B:0.65;95%CI:0.30,1.01), higher corneal refractive power (P<0.001;beta:0.08;B:0.19;95%CI:0.06,0.32), more myopic refractive error (P = 0.03;beta: −0.06;B: −0.12;95%CI: −0.22, −0.01), and higher estimated CSFP (P<0.001;beta:0.11;B:0.17;95%CI:0.09,0.24).

Conclusions

In school children, higher IOP was associated with steeper corneal curvature and with younger age and higher blood pressure, or alternatively, with higher estimated CSFP. Corneal curvature radius should be included in the correction of IOP measurements. The potential association between IOP and CSFP as also assumed in adults may warrant further research.  相似文献   

11.
Several single nucleotide polymorphisms (SNPs) of the Glutamate metabotrophic receptor 7 gene (GRM7) have recently been identified by the genome-wide association study (GWAS) as potentially playing a role in susceptibility to age-related hearing impairment (ARHI), however this has not been validated in the Han Chinese population. The aim of this study was to determine if these SNPs are also associated with ARHI in an elderly male Han Chinese population. In this case-control candidate genes association study, a total of 982 men with ARHI and 324 normal-hearing controls subjects were studied. Using K-means cluster analysis, four audiogram shape subtypes of ARHI were identified in the case group: ‘‘flat shape (FL)’’, ‘‘sloping shape (SL)’’, ‘‘2-4 kHz abrupt loss (AL) shape’’ and ‘‘8 kHz dip (8D) shape’’. Results suggested that the SNP rs11928865 (A>T) of GRM7 was significantly associated with ARHI after adjusting for non-genetic factors (p= 0.000472, OR= 1.599, 95%CI= 1.229~2.081). Furthermore, frequency of TT genotype (rs11928865) were significant higher in the SL subgroup and AL subgroup with compared to controls group (p= 9.41E-05, OR= 1.945, 95%CI= 1.393~2.715; p= 0.000109, OR= 1.915, 95%CI= 1.378~2.661 adjusted, respectively) after Bonferroni correction. However, there wasn’t significant difference in the frequency of the TT genotype between cases in the FL subgroup or the 8D subgroup with when compared with controls. Results of the current study suggest that, in an elderly male Han Chinese population, GRM7 SNP rs11928865 (TT) occurs more frequently in ARHI patients with SL and AL phenotype patterns.  相似文献   

12.

Background

Lotus is a diploid plant with agricultural, medicinal, and ecological significance. Genetic linkage maps are fundamental resources for genome and genetic study, and also provide molecular markers for breeding in agriculturally important species. Genotyping by sequencing revolutionized genetic mapping, the restriction-site associated DNA sequencing (RADseq) allowed rapid discovery of thousands of SNPs markers, and a crucial aspect of the sequence based mapping strategy is the reference sequences used for marker identification.

Results

We assessed the effectiveness of linkage mapping using three types of references for scoring markers: the unmasked genome, repeat masked genome, and gene models. Overall, the repeat masked genome produced the optimal genetic maps. A high-density genetic map of American lotus was constructed using an F1 population derived from a cross between Nelumbo nucifera ‘China Antique’ and N. lutea ‘AL1’. A total of 4,098 RADseq markers were used to construct the American lotus ‘AL1’ genetic map, and 147 markers were used to construct the Chinese lotus ‘China Antique’ genetic map. The American lotus map has 9 linkage groups, and spans 494.3 cM, with an average distance of 0.7 cM between adjacent markers. The American lotus map was used to anchor scaffold sequences in the N. nucifera ‘China Antique’ draft genome. 3,603 RADseq markers anchored 234 individual scaffold sequences into 9 megascaffolds spanning 67% of the 804 Mb draft genome.

Conclusions

Among the unmasked genome, repeat masked genome and gene models, the optimal reference sequences to call RADseq markers for map construction is repeat masked genome. This high density genetic map is a valuable resource for genomic research and crop improvement in lotus.  相似文献   

13.

Background

To determine the mean values for central corneal thickness (CCT) and intraocular pressure (IOP) and the relationship between these values, in healthy Malay children to serve as reference values in diagnosis and treatment.

Design

A cross-sectional study.

Methodology/Principal Findings

One hundred and eight eyes (54 subjects) of Malay children without diagnosis of ocular abnormality or disease meeting our inclusion and exclusion criteria were selected. The CCT and IOP were measured by specular microscopy and non-contact air-puff tonometry respectively, for analysis and comparison with the values obtained in previous studies. Mean CCT and IOP was found to be 530.87±30.79 µm and 15.65±3.05 mm Hg respectively. CCT was found not to vary with age. A positive relationship was found between CCT and IOP; specifically, with every 100-µm increase in CCT, IOP increased by 3.5 mm Hg.

Conclusions/Significance

CCT and IOP are strongly related in healthy Malay children aged 8 to 16. The mean CCT of Malay children is lower than that of majority children of other ethnic groups, supporting the existence of CCT variation among different populations and that ethnicity should be a key consideration when applying CCT data to the general pediatric population.  相似文献   

14.

Purpose

To investigate normal anterior segment parameters and analyze the possible influencing factors using a dual Scheimpflug system.

Setting

Department of Ophthalmology, Affiliated Sixth People''s Hospital Shanghai Jiao Tong University, Shanghai, China.

Design

A prospective observational case series.

Methods

A total of 153 normal subjects (153 eyes) were studied. The anterior segment parameters, including the central corneal thickness (CCT), anterior chamber depth (ACD), pupil diameter (PD), keratoconus prediction index (KPI), simulated keratometry (SimK) values, anterior instantaneous curvature (AIC), posterior axial curvature (PAC), corneal eccentricity, total corneal power (TCP), axial curvature (AC), total corneal wavefront (TCW), high order aberration (HOA), and spherical aberration (SA), were determined using a dual Scheimpflug analyzer.

Results

The CCT and ACD were both negatively correlated with age (r = −0.203, p = 0.012; r = −0.589, p<0.001). There was no significant difference in the refractive indices of AIC and SimK. Compared with the negative correlation of HOA and SA (r = −0.358, p<0.001), a positive correlation was found between TCW and HOA (r = 0.561, p<0.001). Unlike the decreased tendency of AC, the TCP increased gradually from the center to the periphery in the central 8 mm diameter. TCP showed a significant correlation with AC in the analyzed area.

Conclusions

AIC and SimK provide different information in clinic, but the refractive indices of them showed no difference in this healthy study population, and age should be considered when using CCT and ACD values.  相似文献   

15.
The mechanical response of the cornea subjected to a non-contact air-jet tonometry diagnostic test represents an interplay between its geometry, the corneal material behavior and the loading. The objective is to study this interplay to better understand and interpret the results obtained with a non-contact tonometry test. A patient-specific finite element model of a healthy eye, accounting for the load free configuration, was used. The corneal tissue was modeled as an anisotropic hyperelastic material with two preferential directions. Three different sets of parameters within the human experimental range obtained from inflation tests were considered. The influence of the IOP was studied by considering four pressure levels (10–28 mmHg) whereas the influence of corneal thickness was studied by inducing a uniform variation (300–600 microns). A Computer Fluid Dynamics (CFD) air-jet simulation determined pressure loading exerted on the anterior corneal surface. The maximum apex displacement showed a linear variation with IOP for all materials examined. On the contrary, the maximum apex displacement followed a cubic relation with corneal thickness. In addition, a significant sensitivity of the apical displacement to the corneal stiffness was also obtained. Explanation to this behavior was found in the fact that the cornea experiences bending when subjected to an air-puff loading, causing the anterior surface to work in compression whereas the posterior surface works in tension. Hence, collagen fibers located at the anterior surface do not contribute to load bearing. Non-contact tonometry devices give useful information that could be misleading since the corneal deformation is the result of the interaction between the mechanical properties, IOP, and geometry. Therefore, a non-contact tonometry test is not sufficient to evaluate their individual contribution and a complete in-vivo characterization would require more than one test to independently determine the membrane and bending corneal behavior.  相似文献   

16.

Purpose

To investigate the effects of lenticule creation and subsequent corneal lenticule extraction on corneal deformation parameters during small incision lenticule extraction (SMILE) procedure.

Materials and Methods

In this prospective study, 18 eyes of 10 patients (27.90±7.11 years, −5.64±2.45 diopters) scheduled for SMILE procedure were enrolled. Changes in the corneal deformation parameters, including deformation amplitude (DA), applanation time(AT1 and AT2), applanation length(AL1 and AL2), corneal velocity(CV1 and CV2), peak distance(P.Dist.), radius and intraocular pressure values were measured preoperatively, immediately after lenticule creation and subsequent to corneal lenticule extraction in all eyes with the Corvis Scheimpflug Technology (Corvis ST, OCULUS, Wetzlar, Germany). Repeated measures analysis of variance (ANOVA) with bonferroni-adjusted post hoc comparisons was performed to investigate changes following each step of the procedure.

Results

All surgical procedures were uneventful. A significant difference was detected among the three time points (pre-operation, post-lenticule creation and post lenticule extraction) for AT1 (P<0.001), AT2 (P = 0.001), DA(P<0.001), and IOP(P = 0.002). Bonferroni-adjusted post hoc comparisons indicated that there was no significant change in AT1, AT2, DA, or IOP after lenticule creation (post hoc P>0.05), but there was a significant change in these parameters following subsequent corneal lenticule extraction (post hoc P<0.01), when compared to values obtained pre-operatively. The scheimpflug camera of the Corvis ST demonstrated the intralamellar small gas bubbles formed from the vaporisation of tissue after lenticule creation and a gray zone was observed between the cap and the residual stromal bed after lenticule extraction.

Conclusions

There is a significant change in corneal deformation parameters following SMILE procedure. The changes may be caused predominantly by stromal lenticule extraction, while lenticule creation with femtosecond laser may not have an obvious effect on corneal deformation properties.  相似文献   

17.
Understanding rooting dynamics using the minirhizotron technique is useful for cultivar selection and to quantify nematode damage to roots. A 2-yr microplot study including five bermudagrass (‘Tifway’, Belonolaimus longicaudatus susceptible; two commercial cultivars [TifSport and Celebration] and two genotypes [‘BA132’ and ‘PI 291590’], which have been reported to be tolerant to B. longicaudatus) and two St. Augustinegrass (‘FX 313’, susceptible, and ‘Floratam’ that was reported as tolerant to B. longicaudatus) genotypes in a 5 x 2 and 2 x 2 factorial design with four replications, respectively, was initiated in 2012. Two treatments included were uninoculated and B. longicaudatus inoculated. In situ root images were captured each month using a minirhizotron camera system from April to September of 2013 and 2014. Mixed models analysis and comparison of least squares means indicated significant differences in root parameters studied across the genotypes and soil depths of both grass species. ‘Celebration’, ‘TifSport’ and ‘PI 291590’ bermudagrass, and ‘Floratam’ St. Augustinegrass had significantly different root parameters compared to the corresponding susceptible genotypes (P ≤ 0.05). Only ‘TifSport’ had no significant root loss when infested with B. longicaudatus compared to non-infested. ‘Celebration’ and ‘PI 291590’ had significant root loss but retained significantly greater root densities than ‘Tifway’ in B. longicaudatus-infested conditions (P ≤ 0.05). Root lengths were greater at the 0 to 5 cm depth followed by 5 to 10 and 10 to 15 cm of vertical soil depth for both grass species (P ≤ 0.05). ‘Celebration’, ‘TifSport’, and ‘PI 291590’ had better root vigor against B. longicaudatus compared to Tifway.  相似文献   

18.
Primary open angle glaucoma (POAG) belonging to a group of optic neuropathies, result from interaction between genetic and environmental factors. Study of associations with quantitative traits (QTs) is one of the successful strategies to understand the complex genetics of POAG. The current study attempts to explore the association of variations near/in genes like ATOH7, SIX1/SIX6 complex, CDKN2B, CARD10, and CDC7 with POAG and its QTs including vertical cup to disc ratio (VCDR), central corneal thickness (CCT), intra ocular pressure (IOP), and axial length (AL). Case-control study design was carried out in a sample size of 97 POAG cases and 371 controls from South India. Model-based (additive, recessive, dominant) association of the genotypes and their interaction was carried out between cases and controls using chi-square, linear and logistic regression methods. Nominal significance (P<0.05) was observed for QTs like i) VCDR with SNPs rs1900004 (ATOH7); rs1192415 (CDC7); rs10483727 (SIX1/SIX6), rs9607469 (CARD10); ii) CCT with rs1192415; iii) IOP with rs1900004 and iv) AL with rs1900004 and rs1063192 (CDKN2B). We were able to replicate previously known interactions between ATOH7-SIX6 and SIX6-CDKN2B along with few novel interactions between ATOH7CDC7 and SIX6 with genes including CARD10 and CDC7. In summary, our results suggest that a probable interaction among the candidate genes for QTs, play a major role in determining the individual’s susceptibility to POAG.  相似文献   

19.

Purpose

To describe the corneal and anterior segment determinants of posterior corneal arc length (PCAL) and posterior corneal curvature (PCC).

Methods

Cross-sectional, population-based study of 1069 subjects (1069 eyes) aged 40–80 years, from three major Asian ethnic groups. All underwent anterior segment optical coherence tomography imaging and analysis with Zhongshan Angle Assessment Program. Our main outcome measures were determinants of PCAL and PCC using adjusted, multivariate linear regression analysis, adjusted for confounders to obtain the estimated marginal means (EMM) with standard error (SE).

Results

The overall mean (± SD) of PCC was: 6.51±0.39 mm; and PCAL was: 12.52±0.59 mm. Malays had a relatively longer PCAL (EMM = 12.74 mm, SE = 0.04 mm) than Chinese (EMM = 12.48 mm, SE = 0.03 mm, P<0.001), and Indians (EMM = 12.42 mm, SE = 0.03 mm, P<0.001). Anterior segment parameters had weak-moderate correlations with PCAL, which included: anterior chamber depth (ACD) (r = 0.55, P<0.001), PCC (r = 0.27, P<0.001), anterior corneal curvature (ACC) (r = 0.14, P<0.001) and central corneal thickness (CCT) (r = −0.07, P = 0.023). In multivariate analysis, anterior segment parameters explained only 37.6% of the variance of PCAL, with ACD being the most important determinant (partial R2  = 0.300; P<0.001). The determinants of PCC included ACC, PCAL and CCT (explaining 72.1% variation of PCC), with ACC being the most important determinant (partial R2  = 0.683; P<0.001).

Conclusion

There was moderate correlation of PCAL with ACD, but anterior segment parameters accounted for only a small proportion of the variation in PCAL. The significant differences in PCAL and PCC amongst different Asian ethnic groups suggests that there is a need to consider this factor when planning for anterior segment surgeries such as endothelial keratoplasty.  相似文献   

20.
Members of the Mycobacterium abscessus complex are rapidly growing mycobacteria that are emerging as human pathogens. The M. abscessus complex was previously composed of three species, namely M. abscessus sensu stricto, ‘M. massiliense’, and ‘M. bolletii’. In 2011, ‘M. massiliense’ and ‘M. bolletii’ were united and reclassified as a single subspecies within M. abscessus: M. abscessus subsp. bolletii. However, the placement of ‘M. massiliense’ within the boundary of M. abscessus subsp. bolletii remains highly controversial with regard to clinical aspects. In this study, we revisited the taxonomic status of members of the M. abscessus complex based on comparative analysis of the whole-genome sequences of 53 strains. The genome sequence of the previous type strain of ‘Mycobacterium massiliense’ (CIP 108297) was determined using next-generation sequencing. The genome tree based on average nucleotide identity (ANI) values supported the differentiation of ‘M. bolletii’ and ‘M. massiliense’ at the subspecies level. The genome tree also clearly illustrated that ‘M. bolletii’ and ‘M. massiliense’ form a distinct phylogenetic clade within the radiation of the M. abscessus complex. The genomic distances observed in this study suggest that the current M. abscessus subsp. bolletii taxon should be divided into two subspecies, M. abscessus subsp. massiliense subsp. nov. and M. abscessus subsp. bolletii, to correspondingly accommodate the previously known ‘M. massiliense’ and ‘M. bolletii’ strains.  相似文献   