首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In the last 20 years Escherichia coli O157: H7 has emerged as a new pathogen, causing worldwide disease, death and economic loss. Different studies have revealed important survival characteristics of this pathogen, although there are divergent criteria about its ability to survive in various mayonnaise formulations. We studied the effect of different mayonnaise concentrations (0%, 18%, 37% and 56%) (weight/weight) over the survival of the bacterium in common foods from a neotropical environment (Costa Rica). High [10(7)-10(8) Colony Forming Units (CFU)/ml] and low E. coli populations (10(4)-10(6) CFU/ml) were inoculated, (three replicates) in meat, chopped cabbage and poultry, and mixed with commercial mayonnaise to obtain the concentrations specified. They were incubated at 12 degrees C for 24, 48 and 72 hr. The E. coli O157: H7 enumeration was done according to a standard methodology. Populations of E. coli O157: H7 showed an increasing trend during the first incubation period (48 hr), in all the preparations, regardless of the fat concentration used. Our data indicate that E. coli O157: H7 is capable of surviving and growing in meat, cabbage and poultry mixed with mayonnaise, independently of its concentration.  相似文献   

2.
An O-antigen-specific monoclonal antibody, labeled by horseradish peroxidase-protein A, was used in a hydrophobic grid membrane filter-enzyme-labeled antibody method for rapid detection of Escherichia coli O157 in foods. The method yielded presumptive identification within 24 h and recovered, on average, 95% of E. coli O157:H7 artificially inoculated into comminuted beef, veal, pork, chicken giblets, and chicken carcass washings. In food samples from two outbreaks involving E. coli O157:H7, the organism was isolated at levels of up to 10(3)/g. The lower limit of sensitivity was 10 E. coli O157 per g of meat. Specific typing for E. coli O157:H7 can be achieved through staining with labeled H7 antiserum or tube agglutination.  相似文献   

3.
An O-antigen-specific monoclonal antibody, labeled by horseradish peroxidase-protein A, was used in a hydrophobic grid membrane filter-enzyme-labeled antibody method for rapid detection of Escherichia coli O157 in foods. The method yielded presumptive identification within 24 h and recovered, on average, 95% of E. coli O157:H7 artificially inoculated into comminuted beef, veal, pork, chicken giblets, and chicken carcass washings. In food samples from two outbreaks involving E. coli O157:H7, the organism was isolated at levels of up to 10(3)/g. The lower limit of sensitivity was 10 E. coli O157 per g of meat. Specific typing for E. coli O157:H7 can be achieved through staining with labeled H7 antiserum or tube agglutination.  相似文献   

4.
Undercooked and raw meat has been linked to outbreaks of hemorrhagic diarrhea due to the presence of Escherichia coli O157:H7; therefore, treatment with ionizing radiation was investigated as a potential method for the elimination of this organism. Response-surface methods were used to study the effects of irradiation dose (0 to 2.0 kGy), temperature (-20 to +20 degrees C), and atmosphere (air and vacuum) on E. coli O157:H7 in mechanically deboned chicken meat. Differences in irradiation dose and temperature significantly affected the results. Ninety percent of the viable E. coli in chicken meat was eliminated by doses of 0.27 kGy at +5 degrees C and 0.42 kGy at -5 degrees C. Small, but significant, differences in radiation resistance by E. coli were found when finely ground lean beef rather than chicken was the substrate. Unlike nonirradiated samples, no measurable verotoxin was found in finely ground lean beef which had been inoculated with 10(4.8) CFU of E. coli O157:H7 per g, irradiated at a minimum dose of 1.5 kGy, and temperature abused at 35 degrees C for 20 h. Irradiation is an effective method to control this food-borne pathogen.  相似文献   

5.
The effect of high-pressure (HP) treatments combined with bacteriocins of lactic acid bacteria (LAB) produced in situ on the survival of Escherichia coli O157:H7 in cheese was investigated. Cheeses were manufactured from raw milk inoculated with E. coli O157:H7 at approximately 10(5) CFU/ml. Seven different bacteriocin-producing LAB were added at approximately 10(6) CFU/ml as adjuncts to the starter. Cheeses were pressurized on day 2 or 50 at 300 MPa for 10 min or 500 MPa for 5 min, at 10 degrees C in both cases. After 60 days, E. coli O157:H7 counts in cheeses manufactured without bacteriocin-producing LAB and not pressurized were 5.1 log CFU/g. A higher inactivation of E. coli O157:H7 was achieved in cheeses without bacteriocin-producing LAB when 300 MPa was applied on day 50 (3.8-log-unit reduction) than if applied on day 2 (1.3-log-unit reduction). Application of 500 MPa eliminated E. coli O157:H7 in 60-day-old cheeses. Cheeses made with bacteriocin-producing LAB and not pressurized showed a slight reduction of the pathogen. Pressurization at 300 MPa on day 2 and addition of lacticin 481-, nisin A-, bacteriocin TAB 57-, or enterocin AS-48-producing LAB were synergistic and reduced E. coli O157:H7 counts to levels below 2 log units in 60-day-old cheeses. Pressurization at 300 MPa on day 50 and addition of nisin A-, bacteriocin TAB 57-, enterocin I-, or enterocin AS-48-producing LAB completely inactivated E. coli O157:H7 in 60-day-old cheeses. The application of reduced pressures combined with bacteriocin-producing LAB is a feasible procedure to improve cheese safety.  相似文献   

6.
Molecular beacons (MBs) are oligonucleotide probes that fluoresce upon hybridization. In this paper, we described the development of a real-time PCR assay to detect the presence of Escherichia coli O157:H7 using these fluorogenic reporter molecules. MBs were designed to recognize a 26-bp region of the rfbE gene, coding for an enzyme necessary for O-antigen biosynthesis. The specificity of the MB-based PCR assay was evaluated using various enterohemorrhagic (EHEC) and Shiga-like toxin-producing (STEC) E. coli strains as well as bacteria species that cross-react with the O157 antisera. All E. coli serotype O157 tested was positively identified while all other species, including the closely related O55 were not detected by the assay. Positive detection of E. coli O157:H7 was demonstrated when >10(2) CFU/ml was present in the samples. The capability of the assay to detect E. coli O157:H7 in raw milk and apple juice was demonstrated. As few as 1 CFU/ml was detected after 6 h of enrichment. These assays could be carried out entirely in sealed PCR tubes, enabling rapid and semiautomated detection of E. coli O157:H7 in food and environmental samples.  相似文献   

7.
Primers, specific for a unique base substitution in uidA of Escherichia coli O157:H7, were coupled with oligonucleotides for the shiga-like toxin I (SLT-I) and SLT-II genes in a multiplex PCR assay. A minimum of 10(2) CFU per PCR (10 microliters) was necessary to amplify E. coli O157:H7-specific bands by multiplex PCR. Food particles as well as various unknown metabolic by-products of bacteria inhibited the PCR, but a simple two-step filtration procedure eliminated this inhibition. To reliably generate PCR products, an E. coli inoculum of 10(3) CFU g of food slurry-1 in a nonspecific medium was required with 6 h of enrichment at 37 degrees C. However, when the food homogenate was incubated overnight, E. coli O157:H7 at an initial inoculum of even 1 CFU g-1 was detected.  相似文献   

8.
An immunoassay based on immunomagnetic separation and time-resolved fluorometry was developed for the detection of E. coli O157:H7 in apple cider. The time-resolved fluorescent immunoassay (TRFIA) uses a polyclonal antibody bound to immunomagnetic beads as the capture antibody and the same antibody labeled with europium as the detection antibody. Cell suspensions of 10(1) to 10(8) E. coli O157:H7 and K-12 organisms per ml were used to test the sensitivity and specificity of the assay. The sensitivity of the assay was 10(3) E. coli O157:H7 cells with no cross-reaction with K-12. Pure cultures of E. coli O157:H7 (10(1) to 10(5) CFU/ml) in apple cider could be detected within 6 h, including 4 h for incubation in modified EC broth with novobiocin and 2 h for the immunoassay. When apple cider was spiked with 1 to 10(3) CFU/ml of E. coli O157:H7 and 10(6) CFU/ml of K-12, our data show that the high level of K-12 in apple cider did not impede the detection of low levels of O157:H7. The minimum detectable numbers of cells present in the initial inoculum were 10(2) and 10(1) CFU/ml after 4- and 6-h enrichment. The TRFIA provides a rapid and sensitive means of detecting E. coli O157:H7 in apple cider.  相似文献   

9.
AIMS: To determine the effectiveness of a novel dry air decontamination apparatus in the deactivation of Salmonella serotype Typhimurium DT104 or Escherichia coli O157:H7 on beef surfaces. METHODS AND RESULTS: A laboratory scale dry air decontamination apparatus, capable of producing repeatable and known heating time-temperature cycles on food surfaces was used in decontamination trials. Beef samples were surface inoculated with 7-8 log10CFU cm(-2) of S. Typhimurium DT104 or E. coli O157:H7 and heated at 60, 75, 90 and 100 degrees C using fast and slow heating rates and subsequently held at these temperatures for up to 600 s. A substantial reduction in pathogen numbers was achieved at higher temperatures (90 and 100 degrees C, 4.18-6.06 log10CFU cm(-2)) using both heating rates, but cell survival at these temperatures was also observed. At the lower temperatures, deactivation was small at 60 degrees C in particular it was less than one log unit after 3 min heating. No significant differences were observed when total reductions in pathogen counts were compared for all the temperature/heat up time combinations tested. During slow heating at 90 degrees C, and both heating rates at 100 degrees C, the pattern of deactivation of S. Typhimurium DT104 or E. coli O157:H7 was triphasic. CONCLUSIONS: This study has shown that heating meat surfaces with dry air can achieve substantial reductions in S. Typhimurium DT104 or E. coli O157:H7. As surface decontamination of beef surfaces with dry air had a negative effect on beef colour and appearance, such a decontamination apparatus would be unsuitable for producing meat for retail sale but it could be used to produce safer meat for use in the catering trade. SIGNIFICANCE AND IMPACT OF THE STUDY: This study provides researchers and food processors with data on the dynamic changes in S. Typhimurium DT104 and E. coli O157:H7 counts on intact beef surfaces during heating with dry air under realistic (time-varying) temperature conditions.  相似文献   

10.
AIM: To evaluate the effect of NaCl, growth medium and temperature on the antimicrobial activity of bovine lactoferrin (LF) against Escherichia coli O157:H7 in the presence of different chelating agents. METHODS AND RESULTS: LF (32 mg ml(-1)) was tested against E. coli O157:H7 strain 3081 in Luria broth (LB) and All Purpose Tween (APT) broth with metal ion chelators sodium bicarbonate (SB), sodium lactate (SL), sodium hexametaphosphate (SHMP), ethylene diamine tetraacetic acid (EDTA) or quercetin at 0.5 and 2.5% NaCl at 10 and 37 degrees C. LF and the chelators were tested against four other E. coli O157:H7 strains in LB at 2.5% NaCl and 10 degrees C. LF alone was bacteriostatic against strains 3081 and LCDC 7283 but other strains grew. Antimicrobial effectiveness of LF was reduced in APT broth but enhanced by SB at 2.5% NaCl and 10 degrees C where 4.0 log(10) CFU ml(-1) inoculated cells were killed. EDTA enhanced antimicrobial action of the LF-SB combination. SL alone was effective against E. coli O157:H7 but a reduction in its activity at 2.5% NaCl and 10 degrees C was reversed by LF. The combinations LF-SHMP and LF-quercetin were more effective at 37 degrees C and NaCl effects varied. CONCLUSIONS: LF plus SB or SL were bactericidal toward the same 3/5 E. coli O157:H7 strains and inhibited growth of the others at 2.5% NaCl and 10 degrees C. SIGNIFICANCE AND IMPACT OF THE STUDY: The combination of LF with either SL or SB shows potential for reducing viability of E. coli O157:H7 in food systems containing NaCl at reduced, but growth permissive temperature.  相似文献   

11.
AIMS: The fate of Escherichia coli O157:H7 was investigated during the manufacture of Mozzarella cheese. METHODS AND RESULTS: The Mozzarella cheese was made from unpasteurized milk which was inoculated to contain ca 10(5) cfu ml(-1)E. coli O157:H7. Two different heating temperatures (70 and 80 degrees C), commonly used during curd stretching, were investigated to determine their effects on the viability of E. coli O157:H7 in Mozzarella cheese. Stretching at 80 degrees C for 5 min resulted in the loss of culturability of E. coli O157:H7 strains, whereas stretching at 70 degrees C reduced the number of culturable E. coli O157:H7 by a factor of 10. CONCLUSIONS: The results show that stretching curd at 80 degrees C for 5 min is effective in controlling E. coli O157:H7 during the production of Mozzarella cheese. Brining and storage at 4 degrees C for 12 h was less effective than the stretching. Significance and Impact of the Study: Mozzarella cheese should be free of E. coli O157:H7 only if temperatures higher than or equal to 80 degrees C are used during milk processing.  相似文献   

12.
A circulating-flow piezoelectric biosensor, based on an Au nanoparticle amplification and verification method, was used for real-time detection of a foodborne pathogen, Escherichia coli O157:H7. A synthesized thiolated probe (Probe 1; 30-mer) specific to E. coli O157:H7 eaeA gene was immobilized onto the piezoelectric biosensor surface. Hybridization was induced by exposing the immobilized probe to the E. coli O157:H7 eaeA gene fragment (104-bp) amplified by PCR, resulting in a mass change and a consequent frequency shift of the piezoelectric biosensor. A second thiolated probe (Probe 2), complementary to the target sequence, was conjugated to the Au nanoparticles and used as a "mass enhancer" and "sequence verifier" to amplify the frequency change of the piezoelectric biosensor. The PCR products amplified from concentrations of 1.2 x 10(2) CFU/ml of E. coli O157:H7 were detectable by the piezoelectric biosensor. A linear correlation was found when the E. coli O157:H7 detected from 10(2) to 10(6) CFU/ml. The piezoelectric biosensor was able to detect targets from real food samples.  相似文献   

13.
A disposable amperometric immunosensing strip was fabricated for rapid detection of Escherichia coli O157:H7. The method uses an indirect sandwich enzyme-linked immunoassay with double antibodies. Screen-printed carbon electrodes (SPCEs) were framed by commercial silver and carbon inks. For electrochemical characterization the carbon electrodes were coupled with the first E. coli O157:H7-specific antibody, E. coli O157:H7 intact cells and the second E. coli O157:H7-specific antibody conjugated with horseradish peroxidase (HRP). Hydrogen peroxide and ferrocenedicarboxylic acid (FeDC) were used as the substrate for HRP and mediator, respectively, at a potential +300 mV vs. counter/reference electrode. The response current (RC) of the immunosensing strips could be amplified significantly by 13-nm diameter Au nanoparticles (AuNPs) attached to the working electrode. The results show that the combined effects of AuNPs and FeDC enhanced RC by 13.1-fold. The SPCE immunosensing strips were used to detect E. coli O157:H7 specifically. Concentrations of E. coli O157:H7 from 10(2) to 10(7)CFU/ml could be detected. The detection limit was approximately 6CFU/strip in PBS buffer and 50CFU/strip in milk. The SPCE modified with AuNPs and FeDC has the potential for further applications and provides the basis for incorporating the method into an integrated system for rapid pathogen detection.  相似文献   

14.
The sensitivity and specificity of a polyethylene glycol terminated alkanethiol mixed self-assembled monolayers (SAM) on surface plasmon resonance (SPR) immunosensor to detect Escherichia coli O157:H7 is demonstrated. Purified monoclonal (Mabs) or polyclonal antibodies (PAbs) against E. coli O157:H7 were immobilized on an activated sensor chip and direct and sandwich assays were carried to detect E. coli O157:H7. Effect of Protein G based detection and effect of concentrations of primary and secondary antibodies in sandwich assay were investigated. The sensor surface was observed under an optical microscope at various stages of the detection process. The sensor could detect as low as 10(3)CFU/ml of E. coli O157:H7 in a sandwich assay, with high specificity against Salmonella Enteritidis. The detection limit using direct assay and Protein G were 10(6)CFU/ml and 10(4)CFU/ml, respectively. Results indicate that an alkanethiol SAM based SPR biosensor has the potential for rapid and specific detection of E. coli O157:H7, using a sandwich assay.  相似文献   

15.
In this paper, we describe a novel method for detecting Escherichia coli (E. coli) O157:H7 by using a quartz crystal microbalance (QCM) immunosensor based on beacon immunomagnetic nanoparticles (BIMPs), streptavidin-gold, and growth solution. E. coli O157-BIMPs were magnetic nanoparticles loaded with polyclonal anti-E. coli O157:H7 antibody (target antibody, T-Ab) and biotin-IgG (beacon antibody, B-Ab) at an optimized ratio of 1:60 (T-Ab:B-Ab). E. coli O157:H7 was captured and separated by E. coli O157-BIMPs in a sample, and the streptavidin-gold was subsequently conjugated to E. coli O157-BIMPs by using a biotin-avidin system. Finally, the gold particles on E. coli O157-BIMPs were enlarged in growth solution, and the compounds containing E. coli O157:H7, E. coli O157-BIMPs, and enlarged gold particles were collected using a magnetic plate. The QCM immunosensor was fabricated with protein A from Staphylococcus aureus and monoclonal anti-E. coli O157:H7 antibody. The compounds decreased the immunosensor's resonant frequency. E. coli O157-BIMPs and enlarged gold particles were used as "mass enhancers" to amplify the frequency change. The frequency shift was correlated to the bacterial concentration. The detection limit was 23 CFU/ml in phosphate-buffered saline and 53 CFU/ml in milk. This method could successfully detect E. coli O157:H7 with high specificity and stability. The entire procedure for the detection of E. coli O157:H7 took only 4 h.  相似文献   

16.
AIMS: To investigate whether Escherichia coli O157:H7 maintains acid tolerance in water meat decontamination washing fluids. METHODS AND RESULTS: A rifampicin-resistant derivative of E. coli O157:H7 strain ATCC 43895 was inoculated (10(5) cfu ml(-1)) in spray-washings from meat sprayed with cold (10 degrees C) or hot (85 degrees C) water, stored at 10 degrees C for up to 14 days, and its acid tolerance was assessed at 2 and 8 days by exposure to broth or new washings adjusted to pH 3.5 or 3.7 with lactic or acetic acid. The pathogen survived in the water washings, but it was outgrown by the natural, Pseudomonas-like flora, and it was sensitized to acid. CONCLUSIONS: The acid tolerance of E. coli O157:H7 decreases following exposure to non-acid, but otherwise stressful, conditions prevailing in water meat washings at 10 degrees C. SIGNIFICANCE AND IMPACT OF THE STUDY: These findings suggest that the more intense use of water-based technologies should be included in meat decontamination strategies because they may contribute to enhanced meat safety by inducing acid sensitization in E. coli O157:H7.  相似文献   

17.
A sensitive, specific procedure was developed for detecting Escherichia coli O157:H7 in food in less than 20 h. The procedure involves enrichment of 25 g of food in 225 ml of a selective enrichment medium for 16 to 18 h at 37 degrees C with agitation (150 rpm). The enrichment culture is applied to a sandwich enzyme-linked immunosorbent assay (ELISA) with a polyclonal antibody specific for E. coli O157 antigen as the capture antibody and a monoclonal antibody specific for enterohemorrhagic E. coli of serotypes O157:H7 and O26:H11 as the detection antibody. The ELISA can be completed within 3 h. The sensitivity of the procedure, determined by using E. coli O157:H7-inoculated ground beef and dairy products, including different varieties of cheese, was 0.2 to 0.9 cell per g of food. A survey of retail fresh ground beef and farm raw milk samples with this procedure revealed that 3 (2.8%) of 107 ground beef samples and 11 (10%) of 115 raw milk samples were positive for E. coli O157:H7. Most-probable-number determinations revealed E. coli O157:H7 populations of 0.4 to 1.5 cells per g in the three ground beef samples. In addition to being highly specific, sensitive, and rapid, this procedure is easy to perform and is amenable to use by laboratories performing routine microbiological testing.  相似文献   

18.
Two 5'nuclease-based PCR methods (PCR-LS-50B and PCR-7200) were evaluated to determine their sensitivity for detecting Escherichia coli O157:H7 from pure cultures and in food samples enriched in different media and after different incubation periods. The PCR-7200 method was able to detect E. coli O157:H7 at ± 102 CFU/mL in pure culture in both mECB and EEB. In spiked meat samples, the PCR-7200 procedure was capable of detecting the eaeA gene at lower concentrations than the PCR-LS-50B procedure, regardless of the meat type or enrichment medium. Escherichia coli O157:H7 spiked at 0.3 CFU/mL was detectable after 9 h in EEB, but it was not detected in mECB within 24 h. An enrichment time of 4 h in mECB was needed to detect E. coli O157:H7 when spiked at higher levels (41 CFU/mL). The detection levels reported in this study are similar with other reported PCR-based detection techniques for E. coli O157:H7, however, the 5'nuclease-based assays are less labor intensive and capable of higher sample throughput because of their automated detection and analysis steps.  相似文献   

19.
A sensitive, specific procedure was developed for detecting Escherichia coli O157:H7 in food in less than 20 h. The procedure involves enrichment of 25 g of food in 225 ml of a selective enrichment medium for 16 to 18 h at 37 degrees C with agitation (150 rpm). The enrichment culture is applied to a sandwich enzyme-linked immunosorbent assay (ELISA) with a polyclonal antibody specific for E. coli O157 antigen as the capture antibody and a monoclonal antibody specific for enterohemorrhagic E. coli of serotypes O157:H7 and O26:H11 as the detection antibody. The ELISA can be completed within 3 h. The sensitivity of the procedure, determined by using E. coli O157:H7-inoculated ground beef and dairy products, including different varieties of cheese, was 0.2 to 0.9 cell per g of food. A survey of retail fresh ground beef and farm raw milk samples with this procedure revealed that 3 (2.8%) of 107 ground beef samples and 11 (10%) of 115 raw milk samples were positive for E. coli O157:H7. Most-probable-number determinations revealed E. coli O157:H7 populations of 0.4 to 1.5 cells per g in the three ground beef samples. In addition to being highly specific, sensitive, and rapid, this procedure is easy to perform and is amenable to use by laboratories performing routine microbiological testing.  相似文献   

20.
Growth of Escherichia coli O157:H7 strain ATCC 43895 was monitored at 5, 10, 15, and 25 degrees C in both pure and mixed (1:1) cultures with a gluconate-producing Pseudomonas sp. found in meat to evaluate the effect of the absence and presence of 1% glucose in broth on temperature-dependent competition. The number of colonies of the Pseudomonas strain exceeded 9 log CFU/ml under all conditions tested. The pathogen grew better as the temperature increased from 10 to 15 and 25 degrees C and grew better in pure culture than in mixed cultures. Pseudomonas sp. inhibited E. coli O157:H7 in cocultures with glucose at 10 degrees C, while at 15 degrees C the pathogen exhibited a biphasic pattern of growth with an intermediate inactivation period. Pathogen inhibition was much weaker in cocultures grown without glucose at 10 to 15 degrees C and, irrespective of glucose, at 25 degrees C. These results indicate that glucose enhances the growth inhibition of E. coli O157:H7 by some Pseudomonas spp., potentially due to its rapid uptake and conversion to gluconate, at low (< or = 15 degrees C) temperatures.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号