 共查询到20条相似文献,搜索用时 843 毫秒
1.
Porcine blood was used to examine the relationship between hematocrit levels and wall shear rate patterns in straight and curved artery models under fixed oscillatory flow conditions characteristic of larger arteries. It is demonstrated that porcine blood models both the viscous and elastic components of the 2 Hz complex viscosity of human blood quite accurately over a broad range of shear rates (1-1000 s-1) and hematocrits (20%-80%). For a fixed oscillatory flow waveform (Poiseuille peak shear rate = 168 s-1; mean shear rate 84 s-1), increases in hematocrit produced a decrease in the peak wall shear rate in both the straight and curved artery models and a corresponding decrease in wall shear rate reversal on the inside wall of the curved artery model. The same trends were also observed for oscillatory flows of aqueous glycerin solutions of increasing viscosity in the range of viscosity of the blood samples tested. Aqueous glycerin solutions produced wall shear rate waveforms of the same magnitude and shape as the porcine blood. This indicates that variations in the shear rate, and therefore the shear stress, were caused primarily by changes in the viscous and not the elastic properties of blood. The results suggest that simple Newtonian fluids may be sufficient for in vitro determination of the first order effects to be expected of human blood flow in large vessels having complex geometries and shear rates in or above the range of the present study.  相似文献   

2.
The technical complexity of previous rheometers has tended to limit the availability of blood viscosity data obtained over a wide range of shear rates. However, an automated tube-type viscometer, the Rheolog, has been developed; it employs a disposable flow assembly and less than five minutes are required to obtain blood viscosity results over a shear rate range of 1-1500 s(-1). We have carried out validation studies of the Rheolog using normal human blood and have compared these results with those obtained by cone-plate and Couette viscometers; storage time and temperature effects were also evaluated. Replicate measurements indicated mean CV levels less than 5%, and were independent of hematocrit and shear rate. Rheolog blood viscosity data agreed closely with those from other viscometers: average Rheolog differences from mean cone-plate and Couette values were -0.3% at 28% hematocrit, -1.4% at 41% hematocrit (i.e., native), and 1.0% at 56% hematocrit. Storage at room temperature up to 8 hours and at 4 degrees C up to 4 days had minimal effects whereas notable changes were observed when stored for 3 hours at 37 degrees C. Our results indicate that, within the hematocrit and shear rate limits employed herein, the Rheolog provides rapid, accurate and reproducible blood viscosity data, and suggest its usefulness for both basic science and clinical studies.  相似文献   

3.
This study looks at blood flow through four different right coronary arteries, which have been reconstructed from bi-plane angiograms. Five non-Newtonian blood models, as well as the usual Newtonian model of blood viscosity, are used to study the wall shear stress in each of these arteries at a particular point in the cardiac cycle. It was found that in the case of steady flow in a given artery, the pattern of wall shear stress is consistent across all models. The magnitude of wall shear stress, however, is influenced by the model used and correlates with graphs of shear stress versus strain for each model. For mid-range velocities of around 0.2 m s(-1) the models are virtually indistinguishable. Local and global non-Newtonian importance factors are introduced, in an attempt to quantify the types of flows where non-Newtonian behaviour is significant. It is concluded that, while the Newtonian model of blood viscosity is a good approximation in regions of mid-range to high shear, it is advisable to use the Generalised Power Law model (which tends to the Newtonian model in those shear ranges in any case) in order to achieve better approximation of wall shear stress at low shear.  相似文献   

4.
This study looks at pulsatile blood flow through four different right coronary arteries, which have been reconstructed from biplane angiograms. A non-Newtonian blood model (the Generalised Power Law), as well as the usual Newtonian model of blood viscosity, is used to study the wall shear stress in each of these arteries over the entire cardiac cycle. The difference between Newtonian and non-Newtonian blood models is also studied over the whole cardiac cycle using the recently generalised global non-Newtonian importance factor. In addition, the flow is studied by considering paths of massless particles introduced into the flow field. The study shows that, when studying the wall shear stress distribution for transient blood flow in arteries, the use of a Newtonian blood model is a reasonably good approximation. However, to study the flow within the artery in greater detail, a non-Newtonian model is more appropriate.  相似文献   

5.
The influence of red blood cell (RBC) aggregation on blood flow in vivo has been under debate since early 1900's, yet a full understanding has still has not been reached. Enhanced RBC aggregation is well known to increase blood viscosity measured in rotational viscometers. However, it has been demonstrated that RBC aggregation may decrease flow resistance in cylindrical tubes, due to the formation of a cell-poor zone near the tube wall which results from the enhanced central accumulation of RBC. There is also extensive discussion regarding the effects of RBC aggregation on in vivo blood flow resistance. Several groups have reported increased microcirculatory flow resistance with enhanced RBC aggregation in experiments that utilized intravital microscopy. Alternatively, whole organ studies revealed that flow resistance may be significantly decreased if RBC aggregation is enhanced. Recently, new techniques have been developed to achieve well-controlled, graded alterations in RBC aggregation without influencing suspending phase properties. Studies using this technique revealed that the effects of RBC aggregation are determined by the degree of aggregation changes, and that this relationship can be explained by different hemodynamic mechanisms.  相似文献   

6.
BackgroundAn autogenous arteriovenous fistula is the optimal vascular access for hemodialysis. In the case of brachiocephalic fistula, cephalic arch stenosis commonly develops leading to access failure. We have hypothesized that a contribution to fistula failure is low wall shear stress resulting from post-fistula creation hemodynamic changes that occur in the cephalic arch.MethodsTwenty-two subjects with advanced renal failure had brachiocephalic fistulae placed. The following procedures were performed at mapping (pre-operative) and at fistula maturation (8–32 weeks post-operative): venogram, Doppler to measure venous blood flow velocity, and whole blood viscosity. Geometric and computational modeling was performed to determine wall shear stress and other geometric parameters. The relationship between hemodynamic parameters and clinical findings was examined using univariate analysis and linear regression.ResultsThe percent low wall shear stress was linearly related to the increase in blood flow velocity (p < 0.01). This relationship was more significant in non-diabetic patients (p < 0.01) than diabetic patients. The change in global measures of arch curvature and asymmetry also evolve with time to maturation (p < 0.05).ConclusionsThe curvature and hemodynamic changes during fistula maturation increase the percentage of low wall shear stress regions within the cephalic arch. Low wall shear stress may contribute to subsequent neointimal hyperplasia and resultant cephalic arch stenosis. If this hypothesis remains tenable with further studies, ways of protecting the arch through control of blood flow velocity may need to be developed.  相似文献   

7.
The effects of polar nature of blood and pulsatility on flow through a stenosed tube have been analysed by assuming blood as a micropolar fluid. Linearized solutions of basic equations are obtained through consecutive applications of finite Hankel and Laplace transforms. The analytical expressions for axial and particle angular velocities, wall shear stress, resistance to flow and apparent viscosity have been obtained. The axial velocity profiles for Newtonian and micropolar fluids have been compared. The interesting observation of this analysis is velocity, in certain parts of cycle, for micropolar fluid is higher than Newtonain fluid. Variation of apparent viscosity eta a with tube radius shows both inverse Fahraeus-Lindqvist and Fahraeus-Lindqvist effects. Finally, the resistance to flow and wall shear stress for normal and diseased blood have been computed and compared.  相似文献   

8.
This paper presents Computational fluid dynamic (CFD) analysis of blood flow in three different 3-D models of left coronary artery (LCA). A comparative study of flow parameters (pressure distribution, velocity distribution and wall shear stress) in each of the models is done for a non-Newtonian (Carreau) as well as the Newtonian nature of blood viscosity over a complete cardiac cycle. The difference between these two types of behavior of blood is studied for both transient and steady states of flow. Additionally, flow parameters are compared for steady and transient boundary conditions considering blood as non-Newtonian fluid. The study shows that the highest wall shear stress (WSS), velocity and pressure are found in artery having stenosis in all the three branches of LCA. The use of Newtonian blood model is a good approximation for steady as well as transient blood flow boundary conditions if shear rate is above 100 s-1. However, the assumption of steady blood flow results in underestimating the values of flow parameters such as wall shear stress, pressure and velocity.  相似文献   

9.
A significant amount of evidence linking wall shear stress to neointimal hyperplasia has been reported in the literature. As a result, numerical and experimental models have been created to study the influence of stent design on wall shear stress. Traditionally, blood has been assumed to behave as a Newtonian fluid, but recently that assumption has been challenged. The use of a linear model; however, can reduce computational cost, and allow the use of Newtonian fluids (e.g., glycerine and water) instead of a blood analog fluid in an experimental setup. Therefore, it is of interest whether a linear model can be used to accurately predict the wall shear stress caused by a non-Newtonian fluid such as blood within a stented arterial segment. The present work compares the resulting wall shear stress obtained using two linear and one nonlinear model under the same flow waveform. All numerical models are fully three-dimensional, transient, and incorporate a realistic stent geometry. It is shown that traditional linear models (based on blood's lowest viscosity limit, 3.5 Pa s) underestimate the wall shear stress within a stented arterial segment, which can lead to an overestimation of the risk of restenosis. The second linear model, which uses a characteristic viscosity (based on an average strain rate, 4.7 Pa s), results in higher wall shear stress levels, but which are still substantially below those of the nonlinear model. It is therefore shown that nonlinear models result in more accurate predictions of wall shear stress within a stented arterial segment.  相似文献   

10.
Injured employees require medical care and, if disabled, compensation payments for subsistence. The law requires that the employer or insurance carrier supply these benefits promptly. In the absence of prompt and adequate information from the attending physician, these benefits are withheld. The necessary information required to process employee''s claim is that called for on the standard accident report form, commonly called the “pink slip.” Not to supply this minimum information may constitute a hardship on the employee. By supplying more elaborate information than that called for, the physician may be increasing his load of “paper work” immeasurably.  相似文献   

11.
A “sheath” fluid passing through a microfluidic channel at low Reynolds number can be directed around another “core” stream and used to dictate the shape as well as the diameter of a core stream. Grooves in the top and bottom of a microfluidic channel were designed to direct the sheath fluid and shape the core fluid. By matching the viscosity and hydrophilicity of the sheath and core fluids, the interfacial effects are minimized and complex fluid shapes can be formed. Controlling the relative flow rates of the sheath and core fluids determines the cross-sectional area of the core fluid. Fibers have been produced with sizes ranging from 300 nm to ~1 mm, and fiber cross-sections can be round, flat, square, or complex as in the case with double anchor fibers. Polymerization of the core fluid downstream from the shaping region solidifies the fibers. Photoinitiated click chemistries are well suited for rapid polymerization of the core fluid by irradiation with ultraviolet light. Fibers with a wide variety of shapes have been produced from a list of polymers including liquid crystals, poly(methylmethacrylate), thiol-ene and thiol-yne resins, polyethylene glycol, and hydrogel derivatives. Minimal shear during the shaping process and mild polymerization conditions also makes the fabrication process well suited for encapsulation of cells and other biological components.  相似文献   

12.
Blood is a non-Newtonian, shear-thinning fluid owing to the physical properties and behaviors of red blood cells (RBCs). Under increased shear flow, pre-existing clusters of cells disaggregate, orientate with flow, and deform. These essential processes enhance fluidity of blood, although accumulating evidence suggests that sublethal blood trauma—induced by supraphysiological shear exposure—paradoxically increases the deformability of RBCs when examined under low-shear conditions, despite obvious decrement of cellular deformation at moderate-to-higher shear stresses. Some propose that rather than actual enhancement of cell mechanics, these observations are “pseudoimprovements” and possibly reflect altered flow and/or cell orientation, leading to methodological artifacts, although direct evidence is lacking. This study thus sought to explore RBC mechanical responses in shear flow using purpose-built laser diffractometry in tandem with direct optical visualization to address this problem. Freshly collected RBCs were exposed to a mechanical stimulus known to drastically alter cell deformability (i.e., prior shear exposure (PSE) to 100 Pa × 300 s). Samples were subsequently transferred to a custom-built slit-flow chamber that combined laser diffractometry with direct cell visualization. Cell suspensions were sheared in a stepwise manner (between 0.3 and 5.0 Pa), with each step being maintained for 15 s. Deformability and cell orientation indices were recorded for small-scatter Fraunhofer diffraction patterns and also visualized RBCs. PSE RBCs had significantly decreased visualized and laser-derived deformability at any given shear stress ≥1 Pa. Novel, to our knowledge, observations demonstrated that PSE RBCs had increased heterogeneity of direct visualized orientation with flow vector at any shear, which may be due to greater vorticity and thus instability in 5-Pa flow compared with unsheared control. These findings indicate that shear exposure and stress-strain history can alter subsequent RBC behavior in physiologically relevant low-shear flows. These findings may yield insight into microvascular disorders in recipients of mechanical circulatory support and individuals with hematological diseases that alter physical properties of blood.  相似文献   

13.
The recruitment of leukocytes from the blood stream and their subsequent adhesion to endothelial walls are essential stages to the immune response system during inflammation. The precise dynamic mechanisms by which molecular mediators facilitate leukocyte arrests are still unknown. In this study combined experimental results and computer simulations are used to investigate localized hydrodynamics of individual and collective behavior of clusters of leukocytes. Leukocyte-endothelial cell interactions in post-capillary venules of Wistar rats cremaster muscle were monitored by intravital microscopy. From these experiments the hemorheologic and hemodynamical measured parameters were used in time dependent three-dimensional computer simulations, using a mesoscopic lattice Boltzmann flow solver for shear thinning fluids. The dynamics of leukocyte clusters under generalized Newtonian blood flow with shear thinning viscosity was computed and discussed. In this paper we present quantified distributions of velocity and shear stress on the surface of leukocytes and near vessel wall attachment points. We have observed one region of maximum shear stress and two regions of minimum shear stress on the surface of leukocytes close to the endothelial wall. We verified that the collective hydrodynamic behavior of the cluster of recruited leukocytes establishes a strong motive for additional leukocyte recruitment. It was found that the lattice Boltzmann solver used here is fully adaptive to the measured experimental parameters. This study suggests that the influence of the leukocytes rolling on the increase of the endothelial wall shear stress may support the activation of more signalling mediators during inflammation.  相似文献   

14.
Blood and erythrocyte suspensions have non-linear pressure-flow curves and so do not possess a unique Newtonian coefficient of viscosity (or its reciprocal, the fluidity) except in the physically unrealizable limits of infinite flow rate and tube radius. However, three coefficients can be defined which are related mathematically to one another and which converge in these infinite limits. They are first, the apparent fluidity, which is proportional to the slope of the line joining any given point on the pressure-flow curve with the origin; second, the differential fluidity, which is proportional to the slope of the pressureflow curve itself at any given point; and third, the generalized fluidity which is proportional to the ratio of the shear rate to the applied stress across any given cylindrical lamina (taken here at the tube wall) within the tube. These three coefficients, which are related mathematically to one another, have been calculated from measured pressure-flow curves for erythrocyte suspensions in glass tubes, and the differential viscosity has been used to develop a simple flow model in which the shear-dependent viscosity is assumed to arise from “structural changes” in the fluid as the flow rate increases. Although the physical basis of such structural changes is uncertain, it is likely that some sort of axial redistribution of the red cells is of greatest importance at normal, physiological hematocrit values.  相似文献   

15.
Y I Cho  K R Kensey 《Biorheology》1991,28(3-4):241-262
Effects of the non-Newtonian viscosity of blood on a flow in a coronary arterial casting of man were studied numerically using a finite element method. Various constitutive models were examined to model the non-Newtonian viscosity of blood and their model constants were summarized. A method to incorporate the non-Newtonian viscosity of blood was introduced so that the viscosity could be calculated locally. The pressure drop, wall shear stress and velocity profiles for the case of blood viscosity were compared for the case of Newtonian viscosity (0.0345 poise). The effect of the non-Newtonian viscosity of blood on the overall pressure drop across the arterial casting was found to be significant at a flow of the Reynolds number of 100 or less. Also in the region of flow separation or recirculation, the non-Newtonian viscosity of blood yields larger wall shear stress than the Newtonian case. The origin of the non-Newtonian viscosity of blood was discussed in relation to the viscoelasticity and yield stress of blood.  相似文献   

16.
Measurement of blood viscosity using mass-detecting sensor   总被引:1,自引:0,他引:1  
A newly designed mass-detecting capillary viscometer is extended to measure the viscosity of whole blood over a range of shear rates without the use of anticoagulants in a clinical setting. In the present study as proof of principle, a single measurement of liquid-mass variation with time replaces the flow rate and pressure drop measurements that are usually required for the operation of a capillary tube viscometer. Using a load cell and capillary, we measured the change of mass flowing through capillary tube with respect to the time, m(t), from which viscosity and shear rate were mathematically calculated. For water and adulterated bloods, excellent agreement was found between the results from the mass-detecting capillary viscometer and those from a commercially available rotating viscometer. Also, the mass-detecting capillary viscometer measured the viscosity of unadulterated whole blood without heparin or EDTA. This new method overcomes the drawbacks of conventional viscometers in the measurement of the whole blood viscosity. First, the mass-detecting capillary viscometer can accurately and consistently measure the unadulterated blood viscosity over a range of shear rates in less than 2 min without any anticoagulants. Second, this design provides simplicity (i.e. ease of operation, no moving parts, and disposable) and low cost.  相似文献   

17.
It has been extensively documented that changes in blood flow induce vascular remodeling and this phenomenon seems to be correlated to the shear forces imposed on the vessel wall by motion of blood. Wall shear stress, the tractive force that acts on the endothelium, has been shown to influence endothelial cell function. To study changes in wall shear stress that develop on the vessel wall upon changes of blood flow, we set up a technique that allows estimation of shear stress in the radial artery of patients on chronic hemodialysis therapy. The technique is based on color-flow Doppler examination of the radial artery before and after surgical creation of radiocephalic fistula for hemodialysis. Calculation of time function wall shear stress and blood flow rate in the radial artery is performed on the basis of arterial diameter, center-line velocity waveform and blood viscosity, using a numerical method developed according to Womersley's theory for pulsatile flow in tubes. The results presented confirm that the model developed is suitable for calculation of the wall shear stress that develops in the radial artery of patients before and after surgical creation of an arteriovenous fistula for hemodialysis. This methodology was developed for characterization of wall shear stress in the radial artery but may be well applied to other vessels that can be examined by echo-Doppler technique.  相似文献   

18.
Three non-Newtonian blood viscosity models plus the Newtonian one are analysed for a patient-specific thoracic aorta anatomical model under steady-state flow conditions via wall shear stress (WSS) distribution, non-Newtonian importance factors, blood viscosity and shear rate. All blood viscosity models yield a consistent WSS distribution pattern. The WSS magnitude, however, is influenced by the model used. WSS is found to be the lowest in the vicinity of the three arch branches and along the distal walls of the branches themselves. In this region, the local non-Newtonian importance factor and the blood viscosity are elevated, and the shear rate is low. The present study revealed that the Newtonian assumption is a good approximation at mid-and-high flow velocities, as the greater the blood flow, the higher the shear rate near the arterial wall. Furthermore, the capabilities of the applied non-Newtonian models appeared at low-flow velocities. It is concluded that, while the non-Newtonian power-law model approximates the blood viscosity and WSS calculations in a more satisfactory way than the other non-Newtonian models at low shear rates, a cautious approach is given in the use of this blood viscosity model. Finally, some preliminary transient results are presented.  相似文献   

19.
Platelet-leukocyte adhesion may contribute to thrombosis and inflammation. We examined the heterotypic interaction between unactivated neutrophils and either thrombin receptor activating peptide (TRAP)-stimulated platelets or P-selectin-bearing beads (Ps-beads) in suspension. Cone-plate viscometers were used to apply controlled shear rates from 14 to 3000/s. Platelet-neutrophil and bead-neutrophil adhesion analysis was performed using both flow cytometry and high-speed videomicroscopy. We observed that although blocking antibodies against either P-selectin or P-selectin glycoprotein ligand-1 (PSGL-1) alone inhibited platelet-neutrophil adhesion by approximately 60% at 140/s, these reagents completely blocked adhesion at 3000/s. Anti-Mac-1 alone did not alter platelet-neutrophil adhesion rates at any shear rate, though in synergy with selectin antagonists it abrogated cell binding. Unstimulated neutrophils avidly bound Ps-beads and activated platelets in an integrin-independent manner, suggesting that purely selectin-dependent cell adhesion is possible. In support of this, antagonists against P-selectin or PSGL-1 caused dissociation of previously formed platelet-neutrophil and Ps-bead neutrophil aggregates under shear in a variety of experimental systems, including in assays performed with whole blood. In studies where medium viscosity and shear rate were varied, a shear threshold for P-selectin PSGL-1 binding was also noted at shear rates <100/s when Ps-beads collided with isolated neutrophils. Results are discussed in light of biophysical computations that characterize the collision between unequal-size particles in linear shear flow. Overall, our studies reveal an integrin-independent regime for cell adhesion and weak shear threshold for P-selectin PSGL-1 interactions that may be physiologically relevant.  相似文献   

20.
It was previously shown that mutations of integrin α4 chain sites, within putative EF-hand-type divalent cation-binding domains, each caused a marked reduction in α4β1-dependent cell adhesion. Some reports have suggested that α-chain “EF-hand” sites may interact directly with ligands. However, we show here that mutations of three different α4 “EF-hand” sites each had no effect on binding of soluble monovalent or bivalent vascular cell adhesion molecule 1 whether measured indirectly or directly. Furthermore, these mutations had minimal effect on α4β1-dependent cell tethering to vascular cell adhesion molecule 1 under shear. However, EF-hand mutants did show severe impairments in cellular resistance to detachment under shear flow. Thus, mutation of integrin α4 “EF-hand-like” sites may impair 1) static cell adhesion and 2) adhesion strengthening under shear flow by a mechanism that does not involve alterations of initial ligand binding.  相似文献   