首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Transformer stations in apartment buildings may offer a possibility to conduct epidemiological studies that involve high exposure to extremely low frequency magnetic fields (MF), avoid selection bias and minimize confounding factors. To validate exposure assessment based on transformer stations, measurements were performed in thirty buildings in three Finnish cities. In each building, spot measurements in all rooms and a 24-h recording in a bedroom were performed in one apartment above a transformer station (AAT), in one first floor (FF) reference apartment, and one reference apartment on upper floors (UF). The apartment mean of spot measurements was 0.62 microT in the AATs, 0.21 microT in the FF and 0.11 microT in the UF reference apartments The 24-h apartment mean (estimated from the spot measurements and the bedroom 24-h recording) was 0.2 microT or higher in 29 (97%) AATs, in 7 (25%) FF and in 3 (10 %) UF reference apartments. The corresponding numbers for the 0.4 microT cut-off point were 19 (63%), 4 (14%), and 1 (3.3%). The higher MF level in the FF reference apartments indicates that they should not be considered "unexposed" in epidemiological studies. If such apartments are excluded, a transformer station under the floor predicts 24-h apartment mean MF with a sensitivity of 0.41 (or 0.58) and a specificity of 0.997 (or 0.97), depending on the MF cut-off point (0.2 or 0.4 microT). The results indicate that apartments can be reliably classified as high and low MF field categories based on the known location of transformer stations.  相似文献   

2.
Buildings with indoor transformer stations may serve as a basis for improved epidemiological studies on the health effects of extremely low-frequency magnetic fields (ELF MFs). Previous studies have shown that ELF MF exposure can be adequately assessed based on the fact that MF levels are high in apartments directly above transformers. In this paper, we describe the creation of a registry of Finnish residential buildings with built-in transformer stations and discuss its usability in epidemiological studies. Information obtained from electric utilities and building blueprints were used to identify 677 buildings in which an apartment was located above or adjacent to a transformer station. All apartments in these buildings were classified into exposure categories based on their location in relation to the transformer. Residential histories of these buildings were obtained from the Population Register Centre. Out of the 287,668 individuals who have resided in the buildings, 9,126 of them have resided in an apartment located directly above a transformer station. All information was collected without contacting residents, thus avoiding selection bias. The registry can be linked with data from high-quality nationwide registries to confirm or challenge the reported associations of ELF MF exposure and diseases such as cancer, miscarriage, and Alzheimer's disease. Bioelectromagnetics. 2020;41:34–40 © 2019 Bioelectromagnetics Society.  相似文献   

3.
The purpose of this study was to evaluate residential short term "spot" measurements as surrogates for long term personal magnetic field (MF) exposure. In an epidemiological study on birth weight and pregnancy delay, MF exposure was assessed by taking five spot measurements in each room. For a subsample of 30 subjects 24 h personal MF measurements were made, and the following exposure metrics were calculated: 24 h arithmetic mean, 24 h median, percentage of time above 0.15 microT, and percentage of time above 0.29 microT. The 24 h exposure metrics were used as gold standards, when evaluating the validity of various summary measures calculated from spot measurements for assessing personal exposure. Based on Spearman correlation coefficient (r), specificity and sensitivity, the average of the spot measurements of a residence resulted in least exposure measurement error (misclassification). Also the above bed spot value correlated better with the 24 h metrics than any room average. Spot measurements performed about equally well in predicting different types of exposure metrics.  相似文献   

4.
Occupational magnetic field (MF) exposure is less thoroughly characterized in occupations typically held by women. Our objective was to characterize occupational 50 Hz MF personal exposure (PE) among female sewing machine operators. We measured the full shift PE of 51 seamstresses, who worked in two shifts (6-14 and 14-22 h) according to their normal work routine. Measurements were conducted using EMDEX PAL meters at chest level. The average duration of the measurement periods was 449 min (range 420-470). The average arithmetic mean exposure for all women was 0.76 microT (range 0.06-4.27). The average of maximum values was 4.30 microT (range 0.55-14.80). Women working with older sewing machines experienced higher exposure than women working on newer sewing machines. For women (n = 10) who operated sewing machines produced in 1990 or earlier, the average arithmetic mean exposure was 2.09 microT, and for women (n = 41) who operated sewing machines produced after 1990, the average arithmetic mean was 0.43 microT. We conclude that women working as sewing machine operators experience higher than average occupational MF exposure compared to other working women. Most important determinant of the women's personal MF exposure was the age of the sewing machine the women operated.  相似文献   

5.
We aimed to provide a systematic evaluation of magnetic field (MF) exposure of staff working in the offices located above or close to transformer stations (TS) and electric enclosures (EE). Occupational short-term “spot” measurements with Narda EFA-300 and isotropic magnetic field probe were carried out in two National Banks and one Industrial Company having more than 500 employees. Extremely low-frequency (ELF) MFs up to several tens of μT were measured in the mentioned working environments. 25% of the measured MFs were found less than 0.3 μT, the background exposure level that staff receive at home, 75% were above 0.3 μT with the highest value of 6.8 μT. The mean and median personal exposures were calculated to be 1.19 μT and 0.56 μT, respectively. Most of the staff (83%) is under risk based on epidemiological studies that reported a statistically significant association between risk of leukemia and averaged magnetic fields of 0.2 μT or over. Results showed that risk evaluation should be considered to minimize the possibility of the workers being harmed due to exposure to work-related electromagnetic sources.  相似文献   

6.
This study sought to estimate the relative contribution of exposure to 50 Hz magnetic fields experienced at home, at work/school, or elsewhere to the total exposure over 24 hr. Personal exposure meters were carried by 97 adults and children in the Stockholm area. About half of the subjects lived close (<50 m) to a transmission line and half far (>100 m) away. Spot measurements and calculations for the residential exposure were also made. For subjects living<50 m from the line, the exposure at home contributed about 80% of the total magnetic field exposure, measured in mT-hours. Adults living far away experienced only 38% of the total exposure at home, but children still received 55%. Subjects with low time-weighted average (TWA) exposure both at home and at work spent 84% of their time in fields <0.1 microT, and those with high TWA at both locations spent 69% of their time in fields > or = 0.2 microT. This contrast was diluted if only exposure at one location was considered. For spot measurements and calculations of the residential exposure, both sensitivity and specificity was good. However, the intermediate field exposure category (0.1-0.19 microT) showed poor correlation to the 24 hr personal measurements.  相似文献   

7.
This study compares stationary home measurements with a personal exposure monitor of 60 Hz magnetic fields in a group of 18 people living near a 735 kV line and 17 people living far away from the line. Most of them were white collar workers who worked during the day. They wore a personal Positron meter for 24 h, while a similar meter was left in their home, away from any appliances. For people living away from the line, the impact of residential activities appeared rather weak when considering the average intensity of the field during the awake period (at home): 0.22 microT for personal exposure versus 0.18 microT for stationary measurements (P = 0.09). The impact of residential activities during the awake period was more detectable when using the percentage of time with exposure above 0.78 microT: median 0.4 for personal vs. 0.0 for stationary measurements (P =.01). The temporal variability of the exposure during the awake period was also significantly higher for personal exposure than for stationary measurements. For people living near the line, the intensity of the magnetic field from the line dominated the personal exposure when considering the mean of measurements and the percentage of time above a threshold. However, the temporal variability was greater for the personal exposure during the awake period. Although limited due to its small sample size, the present study seems to demonstrate the usefulness of considering different indexes of exposure when assessing residential exposure to 60 Hz magnetic fields.  相似文献   

8.
We aimed to provide a systematic evaluation of magnetic field (MF) exposure of staff working in the offices located above or close to transformer stations (TS) and electric enclosures (EE). Occupational short-term "spot" measurements with Narda EFA-300 and isotropic magnetic field probe were carried out in two National Banks and one Industrial Company having more than 500 employees. Extremely low-frequency (ELF) MFs up to several tens of μT were measured in the mentioned working environments. 25% of the measured MFs were found less than 0.3?μT, the background exposure level that staff receive at home, 75% were above 0.3?μT with the highest value of 6.8?μT. The mean and median personal exposures were calculated to be 1.19?μT and 0.56?μT, respectively. Most of the staff (83%) is under risk based on epidemiological studies that reported a statistically significant association between risk of leukemia and averaged magnetic fields of 0.2?μT or over. Results showed that risk evaluation should be considered to minimize the possibility of the workers being harmed due to exposure to work-related electromagnetic sources.  相似文献   

9.
Epidemiological studies have indicated a connection between extremely low frequency magnetic flux densities above 0.4 microT (time weighted average) and childhood leukemia risks. This conclusion is based mainly on indoor exposure measurements. We therefore regarded it important to map outdoor magnetic flux densities in public areas in Trondheim, Norway. Because of seasonal power consumption variations, the fields were measured during both summer and winter. Magnetic flux density was mapped 1.0 m above the ground along 17 km of pavements in downtown Trondheim. The spectrum was measured at some spots and the magnetic flux density emanated mainly from the power frequency of 50 Hz. In summer less than 4% of the streets showed values exceeding 0.4 microT, increasing to 29% and 34% on cold and on snowy winter days, respectively. The average levels were 0.13 microT (summer), 0.85 microT (winter, cold), and 0.90 microT (winter, snow), with the highest recorded value of 37 microT. High spot measurements were usually encountered above underground transformer substations. In winter electric heating of pavements also gave rise to relatively high flux densities. There was no indication that the ICNIRP basic restriction was exceeded. It would be of interest to map the flux density situation in other cities and towns with a cold climate.  相似文献   

10.
The effect induced by exposure to 50 Hz magnetic fields (MFs) in immunocytes from the mussel Mytilus galloprovincialis is evaluated. The whole animal was exposed for 15 and 30 min to MF intensities ranging from 200 to 1,000 microT. The changes in the cellular shape of immunocytes, expressed as shape factor (SF), were studied at different times after addition of the chemotacting substance N-formyl-Meth-Leu-Phe (fMLP). Results show that MFs provoke differing delays in fMLP-induced cellular shape changes: 200 microT are ineffective, while levels from 300 microT upwards cause a significant increase in immunocyte SF values compared to controls. Reactivation of the cells is possible up to an intensity of 600 microT. The use of PCO 400, an opener of ATP-sensitive K+ channels, shows that potassium channels are involved in the effect of MFs on M. galloprovincialis immunocytes.  相似文献   

11.
Previous investigations of exposure to electric, magnetic, or electromagnetic fields (EMF) in households were either about electricity supply EMFs or radio frequency EMFs (RF‐EMFs). We report results from spot measurements at the bedside that comprise electrostatic fields, extremely low‐frequency electric fields (ELF‐EFs), extremely low‐frequency magnetic fields (ELF‐MFs), and RF‐EMFs. Measurements were taken in 226 households throughout Lower Austria. In addition, effects of simple reduction measures (e.g., removal of clock radios or increasing their distance from the bed, turning off Digital Enhanced Cordless Telecommunication (DECT) telephone base stations) were assessed. All measurements were well below International Commission on Non‐Ionizing Radiation Protection (ICNIRP) guideline levels. Average night‐time ELF‐MFs (long‐term measurement from 10 pm to 6 am, geometric mean over households) above 100 nT were obtained in 2.3%, and RF‐EMFs above 1000 µW/m2 in 7.1% of households. Highest ELF‐EFs were primarily due to lamps beside the bed (max = 166 V/m), and highest ELF‐MFs because of transformers of devices (max = 1030 nT) or high current of power lines (max = 380 nT). The highest values of RF‐EMFs were caused by DECT telephone base stations (max = 28979 µW/m2) and mobile phone base stations (max = 4872 µW/m2). Simple reduction measures resulted in an average decrease of 23 nT for ELF‐MFs, 23 V/m for ELF‐EFs, and 246 µW/m2 for RF‐EMFs. A small but statistically significant correlation between ELF‐MF exposure and overall RF‐EMF levels of R = 0.16 (P = 0.008) was computed that was independent of type (flat, single family) and location (urban, rural) of houses. Bioelectromagnetics 31:200–208, 2010. © 2009 Wiley‐Liss, Inc.  相似文献   

12.
Measurements of the flux density and spectra of magnetic fields (MFs) generated by several types of electric bed heaters (EBH) were made in order to characterize the MFs to which the fetus may be exposed in utero from the mother's use of these devices. Data on MFs were gathered from more than 1,300 in-home and laboratory spot measurements. In-home measurements taken at seven different positions 10 cm from the EBHs determined that the mean flux density at the estimated position of the fetus relative to the device was 0.45 μT (4.5 mG) for electric blankets and 0.20 μT (2.0 mG) for electrically heated water beds. A rate-of-change (RC) metric applied to the nighttime segment of 24 h EMDEX-C personal-dosimeter measurements, which were taken next to the bed of volunteers, yielded an approximate fourfold to sixfold higher value for electric blanket users compared to water-bed heater users. These same data records yielded an approximate twofold difference for the same measurements when evaluated by the time-weighted-average (TWA) MF exposure metric. Performance of exposure meters was checked against standard fields generated in the laboratory, and studies of sources of variance in the in-home measurement protocols were carried out. Spectral measurements showed that the EBH's measured produced no appreciable high-frequency MFs. Data gathered during this work will be used in interpreting results from a component of the California Pregnancy Outcome Study, which evaluates the use of EBHs as a possible risk factor in miscarriage. © 1996 Wiley-Liss, Inc.  相似文献   

13.
Plasma membrane Ca(2+) channels in immunocytes from the mussel Mytilus galloprovincialis exposed to 50 Hz sine wave magnetic fields (MFs) of various strengths were studied. At levels of 300 microT and above, MFs reduce shape changes in immunocytes induced by the chemotactic substance N-formyl-Meth-Leu-Phe, and this effect involves L-type Ca(2+) channels. Upon the addition of the Ca(2+) blocker verapamil to molluscan immunocytes exposed to MFs results in a synergistic cytotoxic action, while in the presence of the Ca(2+) opener SDZ-202, 791, a reactivation of the cells is observed. This suggests that, as previously reported for potassium channels, the damage to Ca(2+) channels induced by short exposure to MF at appropriate intensities is not permanent.  相似文献   

14.
15.
The possible effects of repeated night-time exposure to an extremely low frequency magnetic field (ELF-MF) on melatonin were investigated in nine healthy male subjects aged 23-37 yr. The 16-week experiment consisted of 3 weeks of pre-exposure, 11 weeks of night-time exposure to MF generated from a nonheated electric sheet (ES), and 2 weeks of post-exposure recovery observation. The average MF intensity (rms, mainly 50 Hz AC) on the surface of the sheet was 0.7 microT at the head, 8.3 microT at the waist, and 3.5 microT at the feet of the subject. For each of the urine samples collected 5 times a day on scheduled sampling days, the urinary excretion rate (ng/h) of melatonin was determined, and 24 h rhythms were extracted for each subject and each experimental period (pre-exposure, first half and latter half exposure, and post-exposure periods) by the method of complex cosine curve fitting. Although estimates of the peak height, acrophase, and total daily amount of melatonin were characterized by significant variations among individual subjects, they did not reveal any statistically significant difference between exposure periods and nonexposure periods. Thus, the present study indicates that any profound effect of the MF originating from an ES on nocturnal melatonin production and its circadian rhythm is unlikely.  相似文献   

16.
We assessed potential non-response bias in obtaining information on residential extremely low-frequency power frequency magnetic field (MF) in Taiwan. All households occupied by children aged less than 7 years in two study districts, one in an urban town and the other in a rural town, were visited and solicited for on-site measurements in late 2003. The initial response rate was only 32% (33/104, urban) and 60% (61/101, rural). In the same season 1 year later, we performed a second survey of those who declined to be measured at the initial survey and successfully measured another 77 residences (50 and 27 for urban and rural districts, respectively). The two districts were selected mainly because the local public health officers were quite willing to assist the initial survey and to inform residents of the second survey. Except for meteorological conditions, the two surveys came up with very similar findings regarding residential characteristics and power facilities surrounding the houses. The mean residential MF for the urban residences was .121 and .140 micro-Tesla (microT) (P = .620) for the two surveys. The corresponding figures for the rural residences were .119 and .115 microT (P = .802). Although limited in its scope, this study tends to indicate that measurement studies of residential MF are less likely to suffer from serious selection bias if sampling is confined within a small district where people have similar socioeconomic characteristics.  相似文献   

17.
Several epidemiologic studies have suggested an association between exposure to extremely low frequency (ELF) magnetic fields (MFs) and cancer in adults and children. A possible target of MFs is the immune system. The effects of the exposure to ELF MFs on the immunological functions of human peripheral blood mononuclear cells (PBMCs) obtained from healthy male volunteers were assessed by measuring the natural killer (NK) and lymphokine activated killer (LAK) activities and the production of interferon-gamma (IFN-gamma), tumor necrosis factor-alpha (TNF-alpha), interleukin-2 (IL-2), and interleukin-10 (IL-10). The PBMCs were exposed to three different MF: linearly polarized (vertical), circularly polarized, and elliptically polarized, at 50 and 60 Hz. Magnetic flux densities were set at 500, 100, 20, and 2 microT (rms) for vertical field and at 500 microT (rms) for the rotating fields. Using cytotoxicity assay and enzyme-linked immunosorbent assay (ELISA) for cytokine production, we could not find any effects of ELF MFs on the cytotoxic activities and the cytokines production of human PBMCs.  相似文献   

18.
This study investigates the individual magnetic field exposures at 16 2/3 and 50 Hz of 1952 people, selected from the Bavarian population. Personal flux density meters ("Field Watcher FW2A") were worn by the participants for 24 h. Every second, the flux density was recorded for both frequencies and for the three spatial axes (dynamic range per axis: several nT up to 100 microT at 50 Hz, 150 microT at 16 2/3 Hz). For 50 Hz fields, the mean of the 1,952 individual means was 0.101 microT and that of the individual medians was 0.047 microT. High level exposures occurred mainly during working hours. Only 2.4% of the subjects showed individual medians higher than 0.2 microT. About 53% of all volunteers were working on the day of recording. Levels for craftsmen (n = 148; mean individual mean: 0.166 microT) were generally higher than those for office workers (n = 624; mean individual mean: 0.107 microT). Flux densities exceeding 100 microT at 50 Hz were measured in 31 persons. The total time with such extreme exposures amounts to nearly 21 min, less than 0.001% of the total time for all measurements (5.3 years). To our knowledge, this is the first exposure study where 16 2/3 Hz magnetic fields (caused by electrified railways) have additionally been monitored over 24 h. For persons living next to railway lines, the mean individual mean (0.156 microT) and mean individual median (0.102 microT) were calculated. Over all, the mean exposures are only 0.1% of the magnetic flux density limit for 50 Hz (100 microT) and about 0.05% of the limit (300 microT) for 16 2/3 Hz recommended by the International Commission on Non-Ionizing Radiation Protection.  相似文献   

19.
20.
We have recently reported that exposure of pregnant rats to 60 Hz at field strengths up to 0.5 mT during the entire period of pregnancy did not induce any biologically significant effects on both pregnant dams and embryo-fetal development. The present study was carried out to investigate the potential effects of gestational and lactational MF exposure on pregnancy, delivery, and lactation of dams and growth, behavior, and mating performance of their offspring in rats. Timed-pregnant female Sprague-Dawley (SD) rats (24/group) received continuous exposure to 60 Hz magnetic field (MF) at field strengths of 0 (sham control), 5 microT, 83.3 microT, or 0.5 mT. Dams received MF or sham exposures for 21 h/day from gestational day 6 through lactational day 21. Experimentally generated MF was monitored continuously throughout the study. No exposure-related changes in clinical signs, body weight, food consumption, pregnancy length, and necropsy findings were observed in dams. Parameters of growth, behavior, and reproductive performance of offspring showed no changes related to MF exposure. There were no adverse effects on embryo-fetal development of F2 offspring from dams exposed to MF. In conclusion, exposure of pregnant SD rats to 60 Hz at field strengths up to 0.5 mT from gestational day 6 to lactational day 21 did not produce biologically significant effects in dams, F1 offspring, or F2 fetuses.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号