首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A method for the determination of L-756 423, a novel HIV protease inhibitor, in human plasma and urine is described. Plasma and urine samples were extracted using 3M Empore extraction disk cartridges in the C18 and MPC (mixed-phase cation-exchange) formats, respectively. The extract was analyzed using HPLC with fluorescence detection (ex 248 nm, em 300 nm), and included a column switching procedure to reduce run-time. The assay was linear in the concentration range 5 to 1000 ng/ml when 1-ml aliquots of plasma and urine were extracted. Recoveries of L-756 423 were greater than 84% over the calibration curve range using the described sample preparation procedures. Intra-day precision and accuracy for this assay was less than 9% RSD and within 7%, respectively. Inter-day variabilities for the plasma (n=17) and urine (n=10) were less than 5% and 3% for low (15 ng/ml) and high (750 ng/ml) quality control samples. Bovine serum albumin (0.5%) was used as an additive to urine to prevent precipitation of L-756 423 during the storage of clinical samples. The assay was used in support of human clinical trials.  相似文献   

2.
A sensitive HPLC method for the quantification of praziquantel enantiomers in human serum is described. The method involves the use of a novel disc solid-phase extraction for sample clean-up prior to HPLC analysis and is also free of interference from trans-4-hydroxypraziquantel, the major metabolite of praziquantel. Chromatographic resolution of the enantiomers was performed on a reversed-phase cellulose-based chiral column (Chiralcel OJ-R) under isocratic conditions using a mobile phase consisting of 0.1 M sodium perchlorate–acetonitrile (66:34, v/v) at a flow-rate of 0.5 ml/min. Recoveries for R-(−)- and S-(+)-praziquantel enantiomers were in the range of 84–89% at 50–500 ng/ml levels. Intra-day and inter-day precisions calculated as R.S.D. were in the ranges of 3–8% and 1–8% for both enantiomers, respectively. Intra-day and inter-day accuracies calculated as percent error were in the 0.2–5% and 0.3–8% ranges for both enantiomers, respectively. Linear calibration curves were in the concentration range 10–600 ng/ml for each enantiomer in serum. The limit of quantification of each enantiomer was 10 ng/ml. The detection limit for each enantiomer in serum using a UV detector set at 210 nm was 5 ng/ml (S/N=2).  相似文献   

3.
A sensitive and stereospecific method for the quantitation of trimipramine enantiomers in human serum was developed. The assay involves the use of a novel mixed-mode disc solid-phase extraction for serum sample clean-up prior to HPLC analysis and is also free of interference from the enantiomers of desmethyltrimipramine, 2-hydroxytrimipramine, and 2-hydroxydesmethyltrimipramine, the three major metabolites of trimipramine. Chromatographic resolution of trimipramine enantiomers was performed on a reversed-phase cellulose-based chiral column (Chiralcel OD-R) under isocratic conditions using a mobile phase consisting of 0.3 M aqueous sodium perchlorate-acetonitrile (58:42, v/v) at a flow-rate of 0.5 ml/min. Recoveries for R- and S-trimipramine enantiomers were in the range of 93–96% at 25–185 ng/ml levels. Intra-day and inter-day precisions calculated as R.S.D. were in the ranges of 0.30-8.00% and 1.60-10.20% for both enantiomers, respectively. Intra-day and inter-day accuracies calculated as percent error were in the 0.01–2.10% and 1.00–3.00% ranges for both enantiomers, respectively. Linear calibration curves were in the concentration range 15–250 ng/ml for each enantiomer in serum. The limit of quantification of each enantiomer was 15 ng/ml. The detection limit for each enantiomer in serum using a UV detector set at 210 nm was 10 ng/ml (S/N =2). In addition, separation of the enantiomers of desmethyltrimipramine, 2-hydroxytrimipramine, and 2-hydroxydesmethyltrimipramine were investigated. The desmethyltrimipramine enantiomers could be resolved on the Chiralcel OD-R column under the same chromatographic conditions as the trimipramine enantiomers, but the other two metabolite enantiomers required different mobile phases on the Chiralcel OD-R column to achieve satisfactory resolution with Rs values of 1.00.  相似文献   

4.
An HPLC method was developed and validated for the determination of mifepristone in human plasma. C(18) solid-phase extraction cartridges were used to extract plasma samples. Separation was by C(18) column; mobile phase, methanol-acetonitrile-water (50:25:25, v/v/v); flow rate, 0.8 ml/min; UV detection at 302 nm. The calibration curve was linear in the concentration range of 10 ng/ml to 20 microg/ml (r=0.9991). Within- and between-day variability were acceptable. The limit of detection for the assay was 6 ng/ml. Plasma samples were stable for at least 7 days in the state of plasma or residue treated at -20 degrees C. The method was simple, sensitive and accurate, and allowed to determine ng mifepristone in human plasma. It could be applied to assess the plasma level of mifepristone in women receiving low oral doses of mifepristone.  相似文献   

5.
A method was developed and validated for the direct enantioselective assay of fluoxetine and norfluoxetine in human plasma or serum by two-dimensional capillary gas-liquid chromatography (GC). A Rtx-1 fused-silica capillary (15 mx0.25 mm I.D., 1.0 micrometer film thickness) and a hydrodex-beta-6-TBDM fused-silica capillary (25 mx0.25 mm I.D., 0.25 micrometer film thickness) were used. A three-step liquid-liquid extraction was used for sample preparation with fluvoxamine and nisoxetine as internal standards. The method provided linear calibration between about 5 and 250 ng/ml for (R)- and (S)-fluoxetine as well as 15 and 250 ng/ml for (R)- and (S)-norfluoxetine. The limits of detection were about 1.5 and 6 ng/ml, respectively. Intra-day precision (coefficient of variation) was estimated as being between 5.4 and 12.7% at plasma levels of 25, 100 and 200 ng/ml for the four enantiomers. Inter-day precision was between 5.3 and 9.1% at 100 ng/ml. The enantioselective separation of some racemic psychopharmaceuticals was tested with various cyclodextrin GC-capillaries. Advantages and disadvantages of direct enantioselective GC are discussed for the assay of racemic psychopharmaceuticals. Samples from a patient who was treated with racemic fluoxetine were measured. In agreement with literature, plasma levels of the (R)-enantiomers of fluoxetine and norfluoxetine were considerably decreased in comparison to the (S)-enantiomers.  相似文献   

6.
A sensitive and selective method was developed for the simultaneous determination of chloroquine (CQ) and its desethylated metabolites monodesethylchloroquine (DCQ) and bisdesethylchloroquine (BDCQ) in human liver microsomes. Analytes were separated on a C1 column using methanol-water (70:30, v/v) and triethylamine (0.1% v/v) as the mobile phase. The fluorescence detector was set at 250 (excitation) and 380 nm (emission). Following protein precipitation with ice-cold acetonitrile, microsomal incubation supernatants were directly injected into the HPLC system. Typically, 200 μl of incubate were diluted with 200 μl of acetonitrile and 15 μl were injected. The limit of quantitation was 78 nM of CQ or metabolite. Intra-day variability averaged 2.9% for CQ, 1.5% for DCQ and 2.5% for BDCQ. Inter-day variability was 3.1% for CQ, 3.5% for DCQ and 3.7% for BDCQ. Mean accuracies were 100% for CQ and BDCQ and 102% for DCQ.  相似文献   

7.
An improved HPLC method was developed for the determination of sildenafil concentrations in plasma. Analysis of sildenafil in plasma samples was simplified by utilizing a one-step liquid-liquid extraction after alkaline treatment of only 1 ml of plasma. The lower limit of quantitation was 10 ng/ml with a coefficient of variation of less than 20%. A linear range was found to exist from 10 to 1000 ng/ml. This HPLC method was validated with precisions (coefficient of variation, C.V.) for inter- and intra-day runs of 0.41-11.15% and 0.36-8.05%, respectively, and accuracies (the relative error of the mean, REM) for inter- and intra-day runs of -8.72-6.81% and 0.41-11.15%, respectively. A bioavailability study of sildenafil was performed on one normal healthy male volunteer by analyzing sildenafil plasma concentrations with this validated HPLC method. Results demonstrated that this HPLC method is appropriate for applications to bioavailability studies of sildenafil. In addition, an example of the influence of the co-administration of grapefruit juice on sildenafil pharmacokinetics in a healthy volunteer is presented.  相似文献   

8.
Ertapenem is a new once-a-day antibiotic with excellent coverage of common community gram negative and gram positive aerobes and anaerobes. It demonstrates nonlinear protein binding in human plasma (about 94% bound). An assay for unbound drug was developed to study the pharmacokinetics of unbound ertapenem in plasma. Unbound drug is separated from plasma samples (1.0 ml) by ultrafiltration using a Centrifree((R)) centrifugal filter device. Ertapenem (vulnerable to hydrolysis of the beta-lactam moiety) is stabilized in the filtrate by adding an equal volume of 0.1 M MES buffer, pH 6.5 and then is analyzed by reversed-phase high-performance liquid chromatography (HPLC) with ultraviolet (UV) absorbance detection (300 nm). Non-specific binding to the Centrifree((R)) device is <3%. A suitable internal standard is not available. The assay is specific and linear over the concentration range of 0.25 to 100 microgram/ml in plasma filtrate. The lower limit of quantitation (LLOQ) is 0.25 microgram/ml. Intra-day precision is C.V.<10% and accuracy ranges from 97 to 101% of nominal concentration. Inter-day precision and accuracy were determined using quality control samples (QCs) prepared in plasma ultrafiltrate at 0.5, 12 and 80 microgram/ml and stored at -70 degrees C with stabilizer. Inter-day assay accuracy and precision ranged from 100 to 111% of nominal concentration and 1.8 to 5.3% C.V. (n=40), respectively. The assay has been used to analyze plasma samples from subjects receiving 500 and 2000 mg i.v. doses of ertapenem (30 min infusion).  相似文献   

9.
This paper describes a method of determining clioquinol levels in hamster plasma and tissue by means of HPLC and electrochemical detection. Clioquinol was separated on a Nucleosil C18 300 mm x 3.9 mm i.d. 7 microm column at 1 ml/min using a phosphate/citrate buffer 0.1M (400 ml) with 600 ml of a methanol:acetonitrile (1:1, v/v) mobile phase. The retention times of clioquinol and the IS were, respectively, 11.6 and 8.1 min; the quantitation limit (CV>8%) was 5 ng/ml in plasma and 10 ng/ml in tissues. The intra- and inter-assay accuracies of the method were more than 95%, with coefficients of variation between 3.0 and 7.7%, and plasma and tissue recovery rates of 72-77%. There was a linear response to clioquinol 5-2000 ng/ml in plasma, and 10-1000 ng/g in tissues. The method is highly sensitive and selective, makes it possible to study the pharmacokinetics of plasma clioquinol after oral administration and the distribution of clioquinol in tissues, and could be used to monitor plasma clioquinol levels in humans.  相似文献   

10.
An analytical method for the determination of lycopene in tissues and plasma of rats is described. The method was validated for the determination of lycopene in liver and plasma with respect to selectivity, linearity, accuracy, recovery and precision. Following precipitation of proteins with water–ethanol plasma was extracted with hexane; tissues were extracted with acetone followed by precipitation of proteins with water–ethanol and extraction of lycopene with hexane. Separation and quantification of geometrical isomers of lycopene was achieved by normal-phase HPLC with UV/VIS detection at 471 nm. The method proved to be selective and specific for lycopene in plasma and liver. Detector response was linear in the range from 2 ng/g to 10 μg/g liver and 0.5 ng/ml to 2 μg/ml plasma, respectively. Average recoveries ranged from 96 to 101% in spiked liver samples and from 91 to 94% in spiked plasma samples. Intra-day variability (C.V.) was ≤6% and ≤5% in liver and plasma, respectively. Inter-day precision was ≤9% for liver samples and ≤6% for plasma samples. The procedures were successfully applied to the sample analysis of pharmacokinetic and metabolism studies.  相似文献   

11.
This study describes a new simultaneous determination of haloperidol and bromperidol and their reduced metabolites by modification of automated column-switching high-performance liquid chromatography. The test compounds were extracted from 1ml of plasma using chloroform-hexane (30:70 (v/v)), and the extract was injected into a hydrophilic metaacrylate polymer column for clean-up and a C(18) analytical column for separation. The mobile phases consisted of phosphate buffer (0.02M, pH 4.6), perchloric acid (60%) and acetonitrile (54:1:45 (v/v)) and was delivered at a flow-rate of 0.6ml/min. The peak was detected using a UV detector set at 215nm. The method was validated for the concentration range 1-100ng/ml, and good linearity (r >0.999) was confirmed. Intra-day coefficient variations (CVs) for haloperidol, reduced haloperidol, bromperidol and reduced bromperidol were less than 2.5, 3.1, 2.4 and 2.5%, respectively. Inter-day CVs for corresponding compounds were 3.9, 5.1, 2.6 and 4.4%, respectively. Relative errors ranged from -5 to 10% and mean recoveries were 96-100%. The limit of quantification was 1.0ng/m for each compound. This method shows good specificity with respect to commonly prescribed psychotropic drugs, and it could be successfully applied for pharmacokinetic studies and therapeutic drug monitoring, particularly in patients receiving both haloperidol and bromperidol.  相似文献   

12.
Two reversed-phase HPLC methods with UV detection to quantify celiprolol and oxprenolol in human plasma are described. The analytical methods for the determination of both drugs used the same reversed-phase HPLC column, mobile phase and extraction procedure. Linearity was obtained in the ranges 15.63–1000 and 25–800 ng/ml for celiprolol and oxprenolol, respectively. Intra-day and inter-day variation was lower than 14%. After validation of the methods, analytical error functions were established as S.D. (ng/ml)=3.096+0.041C for celiprolol and S.D. (ng/ml)=8.906+8.075·10−8C3 for oxprenolol.  相似文献   

13.
The method presented here is a high-performance liquid chromatography (HPLC)-UV detection method for the determination of baclofen R-(-)- and S-(+)-enantiomers in human plasma using a chiral separation technique. Baclofen enantiomers were extracted from human plasma with a reversed-phase solid-phase extraction (SPE) cartridge. The extract was then injected onto a HPLC system with a UV detection system set at 220 nm. The separation was achieved by using a 150x4.6 mm, 5 microm Phenomenex chirex 3216 chiral column with a mobile phase consisting of 0.4 mM CuSO(4) in acetonitrile-20 mM sodium acetate (17:83). The calibration curves were linear for both R-(-)- and S-(+)-enantiomers of baclofen in the concentration range of 20-5000 ng/ml. The average regressions were 0.9980 and 0.9991 for R-(-)- and S-(+)-baclofen, respectively. Inter-day precision was 3.3-5.2% for R-(-)-baclofen and 3.5-3.9% for S-(+)-baclofen at a concentration range of 60-4000 ng/ml. Intra-day precisions were 0.6-4.4 and 0.5-3.5% for R-(-)-baclofen and S-(+)-baclofen, respectively. The average extraction recovery was 81.6% for R-(-)-baclofen, 83.0% for S-(+)-baclofen and 94.0% for the internal standard (p-aminobenzoic acid). The limit of quantitation for both R-(-)- and S-(+)-baclofen in human plasma was 20 ng/ml. The method is simple and easy to operate with accuracy and reproducibility and it is suitable for pharmacokinetic studies.  相似文献   

14.
A simple and sensitive high-performance liquid chromatography (HPLC) assay for the analysis of CZ48, a potent anticancer candidate, and its active metabolite camptothecin (CPT) in mouse plasma was developed and validated. CZ44 was used as an internal standard (IS). The samples were injected onto a C18 Synergi Polar-RP column (4 microm, 150 mm x 4.60 mm) maintained at 30 degrees C. The identification of peaks showed high specificity. Shimadzu RF-10AXL fluorescence detector was used at the excitation and emission of 380 and 418 nm, respectively. The mean recoveries were 81.41+/-0.035%, 86.00+/-0.053% and 82.21+/-0.020% for CZ48 and 76.01+/-0.028%, 77.04+/-0.042% and 85.93+/-0.023% for CPT at three concentrations of 10, 100 and 900 ng/ml, respectively. The calibration curve was linear (r(2)=0.9999) over CZ48 and CPT concentrations ranging from 5 to 1000 ng/ml and 10-1000 ng/ml (n=6), respectively. The method had an accuracy of >95% and intra- and inter-day precision (RE%) of <1.2% and <2.2% for CZ48 and CPT, respectively, at three different concentrations (10, 100 and 900 ng/ml). The lower limit of quantification (LLOQ) using 0.1 ml mouse plasma was 10 ng/ml for CZ48 and 5 ng/ml for CPT. Stability studies showed that CZ48 and CPT were stable in mouse plasma after 4h incubation at room temperature or after 1 month storage at -80 degrees C with three freeze/thaw cycles. The method reported is simple, reliable, precise and accurate and confirmed by the determination of plasma samples in the mice after oral administration of CZ48.  相似文献   

15.
A liquid chromatography-mass spectrometry (LC-MS) method was developed for the analysis of vancomycin (VCM) in human serum. The method was based on full scan data with extracted ions for the accurate masses of VCM and the atenolol internal standard obtained by Fourier transform MS. VCM was extracted from serum using strong cation exchange (SCX) solid phase extraction (SPE). The method was found to be linear in the range 0.05-10 microg/ml, which was adequate for quantification of VCM in serum samples, with a limit of quantification (LOQ) of 0.005 microg/ml and a limit of detection (LOD) of 0.001 microg/ml. Intra-day precision (n=5) was +/-3.5%, +/-2.5%, +/-0.7% at 0.05, 0.5 and 5 microg/ml, respectively. Inter-day precision (n=5) was +/-7.6%, +/-6.4%, +/-3.9% at 0.05, 0.5 and 5 microg/ml, respectively. The process efficiency for VCM was in the range 89.2-98.1% with the recovery for the atenolol internal standard (IS) being 97.3%. The method was used to determine VCM levels in patients during peri-operative infusion of the drug, which was found to result in drug levels within the required therapeutic window.  相似文献   

16.
There is considerable interest in quantifying morphine and its major metabolites, morphine-3-glucuronide (M3G) and morphine-6-glucuronide (M6G). Available assays use gas chromatography-mass spectrometry or high-performance liquid chromatography (HPLC) with single or tandem mass spectrometry, ultraviolet, electrochemical, or fluorimetric detection. Nevertheless, few methods provide adequate sensitivity for all analytes, in a single injection, with the desired rate of sample throughput. A rapid and sensitive method for quantification of morphine, M3G and M6G from human plasma using HPLC with electrospray ionization mass spectrometry was developed using a Waters Oasis MCX 96-well plate for extracting both lipophilic morphine and its hydrophilic glucuronides, C18 separation using an isocratic mobile phase (methanol, acetonitrile and formic acid), and selected ion monitoring. Recoveries of morphine, M3G and M6G, respectively, were 81, 90 and 82% at the low (2, 25 and 2 ng/ml), 80, 77 and 75% at the medium (10, 250 and 10 ng/ml), and 74, 62 and 72% at the high (100, 1000 and 100 ng/ml) quality control samples. The limit of quantitation was 0.5 ng/ml morphine and M6G, and 5 ng/ml M3G. Analytes were validated over a linear range of 0.5-200 ng/ml morphine and M6G, and 5-2000 ng/ml M3G. This assay represents an improvement over existing methods through solid phase extraction with increased sample throughput (96-well plates), use of small samples (0.5 ml), and sub-nanogram detection.  相似文献   

17.
A sensitive and specific high-performance liquid chromatographic (HPLC) method for the determination of cortisol in only 200 microliters of serum is described. Cortisol and two internal standards, 19-nortestosterone (IS1) and 6 alpha-methylprednisolone (IS2) are extracted with dichloromethane and analyzed on a C18 reversed-phase column eluted with a mobile phase of methanol:water at a flow rate of 0.75 ml/min. Ultraviolet absorption at 254 nm is used for detection and quantitation is performed by peak height ratio measurement. Using 200 microliters of serum, the lower limit of detection for cortisol is 10 ng/ml, the analytical recovery is 104 +/- 3.6% (n = 8), and the day-to-day precision was 1.69% at a level of 90 ng/ml (n = 16). Cortisol values obtained by this method were generally lower than those obtained by radioimmunoassay or by fluorometry. A serum pool was analyzed both by HPLC and by isotope dilution/mass spectrometry (ID/MS). A mean value of 90.1 ng/ml was obtained by HPLC (n = 16, CV = 1.7%), whereas ID/MS yielded a mean of 90.8 ng/ml (n = 28, CV = 0.4%). These results clearly demonstrate the high specificity and the accuracy of the HPLC procedure. The use of two internal standards not only compensates for losses during the sample manipulation but also prevents erroneous results in case of medication by either of these two products.  相似文献   

18.
A simple high-performance liquid chromatography (HPLC)-tandem mass spectrometric method has been developed for determination of propiverine hydrochloride and its metabolite, propiverine N-oxide (M-1) in human plasma using stable isotopes, propiverine hydrochloride-d10 and M-1-d10, as internal standards. The analytes were extracted with dichloromethane from 0.2 ml of plasma in neutral condition (pH 7.0) and separated by HPLC on a C18 reversed-phase column using methanol-1% acetic acid (50:50) as a mobile phase, and detected using positive electrospray ionization in selected reaction monitoring (SRM) mode. The method was validated over a concentration range of 2-500 ng/ml for propiverine hydrochloride and 4-1000 ng/ml for M-1 using 0.2 ml of human plasma per assay. The method developed was successfully applied to analysis of propiverine hydrochloride and M-1 in clinical studies.  相似文献   

19.
Extraction of DMP 450 from plasma was performed with C2 solid-phase extraction columns, using 0.1 M ammonium acetate in 90% methanol to elute DMP 450. The extraction recovery over the range of 10 to 10 000 ng/ml averaged 81.0, 96.2, 77.4, 95.2 and 68.0% from rat, dog, monkey, chimpanzee (25–10 000 ng/ml) and human plasma, respectively. HPLC analysis was carried out with a C18 column and a mobile phase of acetonitrile, methanol and 30 mM potassium phosphate (pH 3), the composition dependent on the type of plasma being analyzed, and monitored at a wavelength of 229 nm. Intra-day and inter-day coefficients of variation were less than 9.9 and 12.9%, respectively. Absolute differences were less than 11.5%.  相似文献   

20.
A simple, selective, sensitive and precise high-performance liquid chromatographic plasma assay for the prokinetic drug cisapride is described. Alkalinised samples of plasma (100 μl) were extracted with 1.0 ml of 10% (v/v) isopropanol in chloroform, dried, redissolved in mobile phase and injected. Chromatography was performed at 20°C by pumping a mobile phase of acetonitrile (370 ml) in pH 5.2, 0.02 M phosphate buffer (630 ml) at 1.0 ml/min through a C8 Symmetry column. Cisapride and the internal standard were detected by fluorescence monitoring at 295 nm (excitation) and 350 nm (emission), and were eluted 5 min and 8 min, respectively, after injection. Calibration plots in bovine serum albumin (3% w/v) were linear (r > 0.999) from 5 to 250 ng/ml. Intra-day and inter-day precision (C.V.) was 9.5%, or less, and the accuracy was within 5.5% of the nominal concentration over the range 8–200 ng/ml. Total assay recovery was above 82%. Endogenous plasma components, major cisapride metabolite (norcisapride), and other durgs used in neonatal pharmacotherapeutics did not interfere.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号