首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
The results of using enzyme immunoassay and latex preparations for the diagnosis of rotavirus gastroenteritis are presented. High effectiveness of the enzyme immunoassay system developed in the USSR with latex diagnostic agents, such as Rotalex (Orion Diagnostica, Finland), Slidex Rota Kit (BioMérieux, France), The Wellcome Rotavirus Latex Kit (Wellcome Foundation Ltd., Great Britain), 48-63% and 21-41% respectively, has been noted. The results of the comparison of the system developed in the USSR with Wellcozyme Rotavirus, an enzyme immunoassay system manufactured by Wellcome Foundation Ltd. (Great Britain), are practically comparable. The results of the block test and the confirmation test used for control indicate that the Soviet preparation is specific. Materials on the practical evaluation of the assay system at health institutions are presented. Good prospects for the use of this system in the diagnosis of rotavirus gastroenteritis, as well as in the realization of epidemiological surveillance on this infection, are substantiated.  相似文献   

2.
Enterococci isolated from water (50 strains), clinical material (50 strains), pork products (25 strains), and other foods (25 strains) as well as 50 known strains were used to compare the abilities of four latex streptococcal grouping kits to correctly identify group D isolates. the Streptex kit (Wellcome Diagnostics) was 98.5% accurate and easiest to interpret. the Slidex Strepto kit (Vitek Systems) and Strepslide kit (NCS Diagnostics) also were acceptable; they were 96.5% and 96.0% accurate, respectively. When the Bacto Strep Grouping kit (Difco Laboratories) was used, 99% of the group D isolates were positive for both group D and group B, including enterococcal strains that are group D-negative.  相似文献   

3.
The prevalence of chronic Toxoplasma infections reported in the literature varies enormously. We hypothesize that one factor could be due to the different methods used in the evaluation of infections. Serological evidence of Toxoplasma infections in 450 pregnant women (PW) and 300 HIV-infected patients (HIV) were investigated by the Sabin–Feldman dye test and two other commercial ELISA kits (kit1 and kit2). Anti-Toxoplasma IgG antibodies obtained from the Sabin–Feldman dye test, ELISA kit1 and ELISA kit2 in the PW subjects were 14.7%, 29.6% and 38.7%, and in the HIV subjects were 13%, 34.7% and 36.3%, respectively. So there were significant differences in the seroprevalences when different diagnostic tests were used (P < 0.05). Regarding Sabin–Feldman dye test as the gold standard for anti-Toxoplasma antibodies detection, we found that the sensitivity and specificity of the ELISA kit1 and kit2 was in the range of their specification. However as the two ELISA kits used in our study identified a much higher prevalence of Toxoplasma infections which indicated that false positive cases were being reported. Based on results obtained, it is therefore highly recommended that research workers should be aware that the reports of serological studies in terms of high positive results should be treated with some skepticism until additional precise diagnostic tools are developed.  相似文献   

4.
目的评价人心脏型脂肪酸结合蛋白(H-FABP)检测试剂盒(胶体金法)在急性心肌梗死(AMI)诊断中的价值。方法采用平行、盲法、对照的对比试验设计,比较其试验产品和对比产品对诊断AMI的敏感性、特异性、准确性。结果共测定240份临床血液标本。试验产品和对比产品的阳性符合率为100%,阴性符合率为96.15%,总符合率为97.92%。对比产品和试验产品结果不一致的5例标本以临床诊断结果为标准进行验证后,试验产品与临床诊断结果的阳性符合率为100%,总符合率为100%。采用Kappa检验考核两种产品测定结果的一致性,Kappa指数为0.958。经McNamara's test分析,两产品之间无差异,χ2=3.20,P>0.05。结论试验产品显示出较好的诊断价值,可以作为AMI早期诊断标志物,试验产品与对比产品等效。  相似文献   

5.
Four lots of the SET-RPLA kit (Denka Seiken Co. Ltd., Tokyo), a commercial reverse passive latex agglutination test kit for the detection of staphylococcal enterotoxins A, B, C, and D in foods, have been evaluated for their efficacy. The kits showed high specificity and sensitivity with a detection limit of 0.75 ng enterotoxin/g of food. The test is simple, is completed within 24 h, and does not require complicated extraction or concentration procedures nor expensive equipment. In addition, the assay is semiquantitative. However, as in any other immunological system, routine verification of the specificity of the latex reagents against standard enterotoxins and toxin-free food extracts is necessary.  相似文献   

6.
A study was performed to validate 3 FMDV 3ABC-I-ELISA kits developed in China for the differentiation of FMDV infected and vaccinated animals. Sets of sera from naive and vaccinated cattle as well as from cattle that had been infected were tested for antibodies against nonstructural proteins (NSPs) of FMDV by commercial diagnosis kits, Ceditest® FMDV-NS (Ceditest® kit), UBI® FMDV NONSTRUCTURAL PROTEIN ELISA DIRECTION INSERT (UBI® kit) and a FMDV 3ABC-I-ELISA kit developed at the Lanzhou Veterinary Research Institute. The test parameters (sensitivity and specificity) of the three kits were determined, and the result obtained from FMD 3ABC-I-ELISA kit was compared with that obtained from two foreign kits. The results indicated that the coincidence rate between the FMDV 3ABC-I-ELISA and Ceditest® kits was 98.05%, and the coincidence rate between the FMDV 3ABC-I-ELISA and UBI® kits was 94.4%; the sensitivity of both Ceditest® and FMDV 3ABC-I-ELISA kit was 100%. However, the sensitivity of the UBI® kit was only 81.8%. With sera from naive or vaccinated non-infected animals, the specificity of all tests exceeded 90%.  相似文献   

7.
A study was performed to validate 3 FMDV 3ABC-I-ELISA kits developed in China for the differentiation of FMDV infected and vaccinated animals.Sets of sera from naive and vaccinated cattle as well as from cattle that had been infected were tested for antibodies against nonstructural proteins (NSPs) of FMDV by commercial diagnosis kits,Ceditest(R)FMDV-NS (Ceditest(R) kit),UBI(R) FMDV NONSTRUCTURAL PROTEIN ELISA DIRECTION INSERT (UBI(R) kit) and a FMDV 3ABC-I-ELISA kitdeveloped at the Lanzhou Veterinary Research Institute.The test parameters (sensitivity and specificity) of the three kits were determined,and the result obtained from FMD 3ABC-I-ELISA kit was compared with that obtained from two foreign kits.The results indicated that the coincidence rate between the FMDV 3ABC-I-ELISA and Ceditest(R) kits was 98.05%,and the coincidence rate between the FMDV 3ABC-I-ELISA and UBI(R) kits was 94.4%; the sensitivity of both Ceditest(R) and FMDV 3ABC-I-ELISA kit was 100%.However,the sensitivity of the UBI(R) kit was only 81.8%.With sera from naive or vaccinated non-infected animals,the specificity of all tests exceeded 90%.  相似文献   

8.
Cyanobacteria blooms may present a public health concern in sources of drinking water and recreational water due to the production of toxins by some species, microcystins being the most commonly found. It is possible to detect microcystins using instrumental analyses and field test kits. While instrumental analysis methods are accurate, they are also costly, and in regions with a high incidence of blooms the time to report is lengthy (days). On the other hand, the use of commercially available test kits may provide quicker results at a lower cost. The purpose of this work was to evaluate three commercially available kits: the Immunochromatographic Strip Test for the Detection of Microcystins and Nodularins in Source Drinking Water at 1 μg/L (Abraxis strip test), the Abraxis Microcystin Tube Kit and the Envirologix QualiTube Kit. The evaluation of each kit focussed on the interpretation of the results by the end-user and the validity of a test kit was based on four indices: sensitivity, specificity, positive predictive rate (PPR) and negative predictive rate (NPR) (false positive/negative) based on the manufacturer's specifications. The results indicate that there are challenges in the visual interpretation of the results at levels close to the threshold value for each kit. The scope of each kit must be understood: free vs. total, qualitative vs. semiquantitative. For instance, the Envirologix Qualitube Kit does not provide a lysing agent, therefore it will underestimate the levels of total microcystin if a lysing step is not included. In the case of the Abraxis strip test, the kit provides information on the absence/presence of microcystin at a threshold value of 1 μg/L, but false positives were encountered.  相似文献   

9.
周杨 《微生物学通报》2017,44(8):1996-2004
【目的】评价基于环介导恒温扩增技术(LAMP)的大肠杆菌O157:H7(Escherichia coli O157:H7)快速检测试剂盒的实效性。【方法】测定快速检测试剂盒的特异性、灵敏度、重复性、保质期以及运输稳定性,并与传统方法对比检测实际样品。【结果】大肠杆菌O157:H7标准菌株样品均检测为阳性,非大肠杆菌O157:H7标准菌株样品均检测为阴性,未发现有交叉反应;试剂盒最低检验限为29 CFU;该试剂盒的特异性、灵敏度及准确度与传统方法相比具有较高的一致性;试剂盒对高菌量目标菌和阴性菌样品的检测重复率均为100%,对低菌量目标菌样品的批间检测重复率为94%。试剂盒可在4°C保存9个月以上,并且可进行变温储存72 h以上。【结论】该试剂盒特异性好,灵敏度高,重复性好,储存方便,检测结果稳定、可靠,适用于对食品中大肠杆菌O157:H7的检测需求。  相似文献   

10.
Three rapid D-dimer test methods were compared for the diagnosis of acute disseminated intravascular coagulation (DIC). These were (a) SimpliRED, an autologous red cell agglutination assay. (b) DIMERTEST latex agglutination assay, containing monoclonal antibody DD-3B6/22(6), and (c) D-DI latex agglutination assay containing mouse anti-human D-dimer monoclonal antibodies. The D-DI latex method having higher sensitivity (100%) and specificity (81%) in clinically acute DIC was postulated as the gold standard and compared with the other two methods. The results suggest that D-DI latex agglutination assay containing mouse anti-human D-Dimer monoclonal antibodies are the better assay methods amongst all the three kits analyzed. It is advisable to look for the nature of the antibody used to coat the latex particles in plasma based kits. In emergency setting RBC kits may be of some use as rapid diagnosis is advantageous.  相似文献   

11.
Country lacks sensitive and indigenous diagnostic kits for the screening of goats and sheep against Johne’s disease. Therefore an indigenous ELISA kit was developed using protoplasmic antigen from native Mycobacterium avium subspecies paratuberculosis ‘Bison Type’ strain of goat origin (Kit 1). In the present study, kit 1 and two commercial kits (kit 2 and 3) were evaluated with respect to ‘Gold Standard’ fecal culture in 71 animals (55 goats and 16 sheep). Kit 1 using indigenous antigen (protoplasmic antigen) was sensitive at very low concentration (0.1 μgm / well) as compared to purified commercial protoplasmic antigen (4 μgm / well) used in kit 2, in the Type 1 reactors (strong positive as positive). Screening of 71 animals by fecal culture detected 38.0% animals (goats-40.0%, sheep-31.2%) as positive (clinical shedders of bacilli) from these farm animals. Of the farm animals located at Central Institute for Research on Goats, herds of goat were endemic whereas, sheep flocks were comparatively resistant to Johne’s disease. The 29.5 and 61.9, 15.4 and 57.7 and 4.2 and 14.0% animals (goats and sheep) were in the category of sero-reactors type 1 and 2 of the ELISA kits 1, 2 and 3, respectively. In the type 1 sero-reactors, sensitivity and specificity of kit 1, 2 and 3 was 53.7 and 86.0, 17.8 and 86.0 and 3.5 and 94.7%, respectively. Indigenous ELISA test (kit 1) was significantly superior for the screening of goatherds and sheep flocks against JD as compared to commercial ELISA kits (Kit 2 and 3). In comparison to kit 2 and 3, kit 1 had highest sensitivity, comparable specificity and substantial to nearly perfect proportional agreement (Kappa Scores) with respect to ‘Gold standard’ fecal culture in goats and sheep. Disease being endemic in herds and flocks screened using ELISA kits, Type I sero-rectors had better correlation with fecal culture in comparison to Type II sero-reactors therefore, used for estimation of sero-prevalence. Newly developed Indigenous ELISA kit was simple, inexpensive, sensitive and reliable for screening of goats and sheep population against Johne’s disease. The study reports high prevalence of Johne’s disease in farm goatherds and sheep flocks, using sensitive tests (fecal culture and ELISA kit). Results of Type 1 reaction in kit 1 were optimally correlated with culture and were good for estimating the sero-prevalence. For controlling Johne’s disease in endemic herds initial removal of the animals in strong positive category (Tyep 1 reactors), may help to remove heavy shedders.  相似文献   

12.
Background. A urine-based enzyme-linked immunosorbent assay (ELISA) kit for detection of antibody to Helicobacter pylori has been developed in Japan. Urine samples can be obtained noninvasively and are easier and safer to handle than are serum samples. The aim of this study was to examine the clinical usefulness of this urine-based ELISA kit.
Materials and Methods. A pair of random, single-void urine and serum samples was collected from each of 1,061 subjects, including 238 patients with gastroduodenal disease. The sensitivity and specificity of the urine-based ELISA was compared with those of three commercially available serum-based ELISA kits. For those patients with gastroduodenal disease, the urine- and serum-based ELISA results were also compared with those for other diagnostic methods using endoscopic biopsy specimens, such as culture, histology, and rapid urease tests.
Results. Based on the three serum-based ELISA results, the sensitivity, specificity, and accuracy of the urine-based ELISA were 97.7%, 95.6%, and 96.8%, respectively. On the basis of the biopsy test results, the sensitivity (96.2%), specificity (78.9%), and accuracy (91.0%) of the urine-based ELISA were almost equivalent or superior to all three serum-based ELISAs tested. In addition, 10 of the 12 false-positive cases for urine-based ELISA were confirmed to be true positives for antibodies to H. pylori by Western blot analysis and inhibition ELISA.
Conclusions. The urine-based ELISA (URINELISA H. pylori Antibody) is very accurate and should be useful as an alternative to serum-based ELISAs for screening of H. pylori infection.  相似文献   

13.
目的评价国产小鼠病毒抗体ELISA检测试剂盒。方法选择国产与进口小鼠淋巴细胞脉络丛脑膜炎病毒(LCMV)、肝炎病毒(MHV)、仙台病毒(SV)、腺病毒(MAV)、细小病毒(MPV)ELISA抗体检测试剂盒,进行敏感性、特异性、精密性、稳定性、可信度试验比较。结果国产与进口试剂盒:同种试剂盒之间灵敏度相差最低为2倍,差异显著(P〈0.05),最高为16倍,差异极显著(P〈0.01);特异性试验显示每种试剂盒,与其他4种病毒均无交叉反应;精密性试验显示5种试剂盒批内平均变异系数均小于10%;稳定性试验显示5种试剂盒相对偏差均小于25%;分别选择已知36份小鼠血清进行检测,国产和进口LCMV、MHV、SV、MPV符合率均为100%;国产MAV符合率为86.1%,进口MAV符合率均为100%,二者之间差异极显著(P〈0.01)。结论除国产MAV试剂盒敏感性、可信度低于进口外,国产LCMV、MHV、SV、MPV试剂盒与进口同种试剂盒相比,在敏感性、特异性、精密性、稳定性和可信度方面均良好。  相似文献   

14.
为评价博尔纳病病毒(Borna disease virus,BDV)核蛋白荧光定量PCR(FQRT-PCR)试剂盒的各项指标,比较分子信标探针相对普通探针的优势,并了解其实际检测效果,本课题组使用BDVOL持续感染细胞株、非BDV病毒序列转染的OL细胞、正常的OL细胞,对BDVRT-PCR试剂盒的敏感性、特异性、重复性和稳定性进行评估,同时检测部分临床病人和动物外周血液RNA。实验结果显示:试剂盒可以检测出的病毒RNA最低浓度为2.5×101,相当于1个病毒拷贝数,无非特异检出;不同批次的试剂盒的检测结果变异系数小于0.7;加速破坏的试剂盒和正常试剂盒检测结果之间变异系数在2以内;对临床病人检测阳性率为3.6%,对动物检测阳性率为4.2%(猪)和1.5%(马)。可见该试剂盒重复性和稳定性均好;敏感性、特异性优于普通探针试剂盒,是BDV基础研究、流行病学调查和临床检测的良好工具。  相似文献   

15.
目的评价肺炎支原体ELISA检测试剂盒在临床应用的效果。方法用肺炎支原体ELISA检测试剂盒检测呼吸道感染患儿的咽拭子标本,并以肺炎支原体快速检测培养基试剂做同步盲法对照试验,分析该试剂盒的准确性及批内、批间产品的稳定性。结果在100例呼吸道感染患儿咽拭子标本中,肺炎支原体ELISA检测法阳性率为38%,肺炎支原体快速检测培养基法阳性率为37%,两种方法阳性结果符合率为97%。同步盲法试验结果显示,肺炎支原体ELISA检测试剂盒批内、批间产品阳性结果的一致率均为100%。结论该试剂盒具有较好的准确度和特异性,并且操作简便、快速,临床可推广应用。  相似文献   

16.
Estradiol (E2) and testosterone (T) are biologically active hormones that serve as important diagnostic markers in serum of premenopausal and postmenopausal women and in men. These hormones are measured frequently by immunoassay in clinical laboratories and the test results are used in the diagnosis and treatment of patients. For measuring the hormones by immunoassay, most laboratories utilize commercially available reagents that are packaged in the form of a kit and are used either in an automated instrument or manually. However, both the diagnostic kit manufacturer and testing laboratory seldom thoroughly validate the assay methods generated with these kits. This deficiency may lead to unreliable test results that could affect clinical evaluation and treatment of patients. The purpose of the present study was to assess the reliability of immunoassays that quantify serum E2 and T levels with commercial diagnostic kits. The data generally show wide differences in the apparent levels of each hormone in a given sample obtained with kits from different manufacturers. This was especially true when measuring postmenopausal E2 and T levels. However, a purification step, which included organic solvent extraction, prior to radioimmunoassay (RIA) of E2 gave values that compared well with those obtained by conventional RIA (with preceding extraction/chromatographic steps). Our results point out the importance of more thoroughly validating assays performed with commercial immunoassay kits, especially with respect to sensitivity and specificity, prior to their use for measuring hormone levels in patient samples.  相似文献   

17.
The diagnostic reliability of the Enzygnost EBV test (DadeBehring, Germany) for the detection of IgG and IgA antibodies in the diagnosis of Epstein-Barr virus (EBV) recurrent disease was investigated. Of 81 serum samples examined there were fourteen asymptomatic patients without EBV infection, 46 with past EBV infection, and 21 patients with EBV reactivation. The Enzygnost EBV test was based on an enzyme-linked immunosorbent assay with a pool of viral antigens. The reliability of IgG at >650 IU/ml, and IgA for the diagnosis of reactivation or chronic persistent EBV infection gave 100% sensitivity, 83.3% and 98.3% specificity, respectively. The data indicated that the appearance of EBV IgA was associated with EBV reactivation together with clinical manifestations.  相似文献   

18.
The first Soviet kits for the serological identification of streptococci, groups A, B, and C, on the basis of the coagglutination test were developed. Each kit was intended for 35-40 determinations. The optimum concentration of streptococci during their identification by means of the reagents making up the kit was about 1.6 x 10(9) cells/ml. The specificity of the reagents in comparison with the results of the identification of streptococci by reference methods was 97.3 +/- 0.9%. The reagents making up the kits can be presumably used for solving a number of practical problems in the epidemiological surveillance of streptococcal infection.  相似文献   

19.
An experiment was conducted to evaluate three commercially available test kits, the Azostix, Multistix and Uric-acid test, for the detection of urine in the equine ejaculate. Azostix, which tests for urea nitrogen, consistently detected urine in the equine ejaculate. Urine contamination was evident when a color change occurred in the reagent pad, going from yellow to green after 10 sec of exposure. The sensitivity of Azostix to urea nitrogen in contaminated samples was 39 mg/dl. The Multistix test kit also successfully detected urine in semen. In the Multistix nitrite pad the color changed from yellow to organge after 3.5 min of exposure to urine-contaminated semen. The Uricacid test kit did not accurately detect urine-contaminated samples. It constantly elicited false positive results in all the control trials. The results of this study show that Azostix and Multistix are cost effective ($1.25 per analysis) and accurate diagnostic aids for detecting urine in the stallion ejaculate.  相似文献   

20.
A simple and rapid immunochromatographic test kit for rabies diagnosis   总被引:1,自引:0,他引:1  
In rabies endemic countries, funds and infrastructure are often insufficient to employ the approved gold standard for the definitive diagnosis of rabies: the direct fluorescent test. In the present study, two types (type 1 and 2) of an ICT kit were evaluated for detection of rabies. These were developed using monoclonal antibodies which recognize epitope II and III of the nucleoprotein of rabies virus. Both kits specifically detected all rabies virus strains and there was no cross reactivity with Lyssaviruses (Lagos, Mokola and Duvenhage), Rhabdovirus (VSV and Oita 296/1972) and other common canine-pathogenic viruses. In type 1, a single type of monoclonal antibody was used. It was capable of detecting recombinant nucleoprotein and showed sensitivity of 95.5% (42/44) and specificity of 88.9% (32/36) using brain samples from rabid dogs. In contrast, type 2 which was made of two different monoclonal antibodies had a lower sensitivity of 93.2% (41/44) and higher specificity of 100% (36/36). These ICT kits provide a simple and rapid method for rabies detection. They need neither cold chain for transportation nor complicated training for personnel. This diagnostic test is suitable for rabies screening, particularly in areas with a high prevalence of rabies and where the fluorescent antibody test is not available.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号