1.
Tissue and stem cell encapsulation andtransplantation were considered as promising tools in the treatment of patients with diabetes mellitus. The aim of this study was to evaluate the effect of microfluidic encapsulation on the differentiation of trabecular meshwork mesenchymal stem cells (TM-MSC), into insulin-producing cells (IPCs) both in vitro and in vivo. The presence of differentiated cells in microfibers (three dimensional [3D]) and tissue culture plates (TCPS; two dimensional [2D]) culture was evaluated by detecting mRNA and protein expression of pancreatic islet-specific markers as well as measuring insulin release of cells in response to glucose challenges. Finally, semi-differentiated cells in microfibers (3D) and 2D cultures were used to control the glucose level in diabetic rats. The results of this study showed that MSCs differentiated in alginate microfibers (fabricated by microfluidic device) express more Pdx-1 mRNA (1.938-fold, p-value: 0.0425) and Insulin mRNA (2.841-fold, p-value: 0.0001) compared with those cultured on TCPS. Furthermore, cell encapsulation in microfluidic derived microfibers decreased the level of blood glucose in diabetic rats. The approach used in this study showed the possibility of alginate microfibers as a matrix for differentiation of TM-MSCs (as a new source) into IPCs. In addition, it could minimize different steps in stem cell differentiation, handling, and encapsulation, which lead to loss of an unlimited number of cells.  相似文献   

2.
The purpose of this study was to demonstrate self-organizing in vitro multicellular tumor spheroid (MCTS) formation in a microfluidic system and to observe the behavior of MCTSs under controlled microenvironment. The employed microfluidic system was designed for simple and effective formation of MCTSs by generating nutrient and oxygen gradients. The MCTSs were composed of cancer cells, vascular endothelial cells, and type I collagen matrix to mimic the in vivo tumor microenvironment (TME). Cell culture medium was perfused to the microfluidic device loaded with MCTSs by a passive fluidic pump at a constant flow rate. The dose response to an MMPs inhibitor was investigated to demonstrate the effects of biochemical substances. The result of long-term stability of MCTSs revealed that continuous perfusion of cell culture medium is one of the major factors for the successful MCTS formation. A continuous flow of cell culture medium in the in vitro TME greatly affected both the proliferation of cancer cells in the micro-wells and the sustainability of the endothelial cell-layer integrity in the lumen of microfluidic channels. Addition of MMP inhibitor to the cell culture medium improved the stability of the collagen matrix by preventing the detachment and shrinkage of the collagen matrix surrounding the MCTSs. In summary, the present constant flow assisted microfluidic system is highly advantageous for long-term observation of the MCTS generation, tumorous tissue formation process and drug responses. MCTS formation in a microfluidic system may serve as a potent tool for studying drug screening, tumorigenesis and metastasis.  相似文献   

3.
A microfluidic technique is described to encapsulate living cells in alginate hydrogel microparticles generated from monodisperse double-emulsion templates. A microcapillary device is used to fabricate double emulsion templates composed of an alginate drop surrounded by a mineral oil shell. Hydrogel formation begins when the alginate drop separates from the mineral oil shell and comes into contact with Ca(2+) ions in the continuous phase. Alginate hydrogel microparticles with diameters ranging from 60 to 230 μm are obtained. 65% of the cells encapsulated in the alginate microparticles were viable after one week. The technique provides a useful means to encapsulate the living cells in monodisperse hydrogel microparticles.  相似文献   

4.
Release of neurotransmitters and hormones by calcium regulated exocytosis is a fundamental cellular/molecular process that is disrupted in a variety of psychiatric, neurological, and endocrine disorders. Therefore, this area represents a relevant target for drug and therapeutic development, efforts that will be aided by novel analytical tools and devices that provide mechanistically rich data with increased throughput. Toward this goal, we have electrochemically deposited iridium oxide (IrOx) films onto planar thin film platinum electrodes (20 μm×300 μm) and utilized these for quantitative detection of catecholamine release from adrenal chromaffin cells trapped in a microfluidic network. The IrOx electrodes show a linear response to norepinephrine in the range of 0-400 μM, with a sensitivity of 23.1±0.5 mA/M mm(2). The sensitivity of the IrOx electrodes does not change in the presence of ascorbic acid, a substance commonly found in biological samples. A replica molded polydimethylsiloxane (PDMS) microfluidic device with nanoliter sensing volumes was aligned and sealed to a glass substrate with the sensing electrodes. Small populations of chromaffin cells were trapped in the microfluidic device and stimulated by rapid perfusion with high potassium (50mM) containing Tyrode's solution at a flow rate of 1 nL/s. Stimulation of the cells produced a rapid increase in current due to oxidation of the released catecholamines, with an estimated maximum concentration in the cell culture volume of ~52 μM. Thus, we demonstrate the utility of an integrated microfluidic network with IrOx electrodes for real-time quantitative detection of catecholamines released from small populations of chromaffin cells.  相似文献   

5.
We have developed a microfluidic platform modeled after the physiologic microcirculation for multiplexed tissue-like culture and high-throughput analysis. Each microfabricated culture unit consisted of three functional components: a 50 microm wide cell culture pocket, an artificial endothelial barrier with 2 microm pores, and a nutrient transport channel. This configuration enabled a high density of cancer cells to be maintained for over 1 week in a solid tumor-like morphology when fed with continuous flow. The microfluidic chip contained 16 parallel units for "flow cell" based experiments where live cells were exposed to a soluble factor and analyzed via fluorescence microscopy or flow-through biochemistry. Each fluidically independent tissue unit contained approximately 500 cells fed with a continuous flow of 10 nL/min. As a demonstration, the toxicity profile of the anti-cancer drug paclitaxel was collected on HeLa cells cultured in the microfluidic format and compared with a 384-well dish for up to 5 days of continuous drug exposure.  相似文献   

6.
In vitro recording of neuronal electrical activity is a widely used technique to understand brain functions and to study the effect of drugs on the central nervous system. The integration of microfluidic devices with microelectrode arrays (MEAs) enables the recording of networks activity in a controlled microenvironment. In this work, an integrated microfluidic system for neuronal cultures was developed, reversibly coupling a PDMS microfluidic device with a commercial flat MEA through magnetic forces. Neurons from mouse embryos were cultured in a 100 μm channel and their activity was followed up to 18 days in vitro. The maturation of the networks and their morphological and functional characteristics were comparable with those of networks cultured in macro-environments and described in literature. In this work, we successfully demonstrated the ability of long-term culturing of primary neuronal cells in a reversible bonded microfluidic device (based on magnetism) that will be fundamental for neuropharmacological studies.  相似文献   

7.
We present for the first time a microfluidic cell culture array for long-term cellular monitoring. The 10 x 10 array could potentially assay 100 different cell-based experiments in parallel. The device was designed to integrate the processes used in typical cell culture experiments on a single self-contained microfluidic system. Major functions include repeated cell growth/passage cycles, reagent introduction, and real-time optical analysis. The single unit of the array consists of a circular microfluidic chamber, multiple narrow perfusion channels surrounding the main chamber, and four ports for fluidic access. Human carcinoma (HeLa) cells were cultured inside the device with continuous perfusion of medium at 37 degrees C. The observed doubling time was 1.4 +/- 0.1 days with a peak cell density of approximately 2.5*10(5) cells/cm(2). Cell assay was demonstrated by monitoring the fluorescence localization of calcein AM from 1 min to 10 days after reagent introduction. Confluent cell cultures were passaged within the microfluidic chambers using trypsin and successfully regrown, suggesting a stable culture environment suitable for continuous operation. The cell culture array could offer a platform for a wide range of assays with applications in drug screening, bioinformatics, and quantitative cell biology.  相似文献   

8.
The present study deals with the development of novel pH-sensitive tamarind seed polysaccharide (TSP)-alginate composite beads for controlled diclofenac sodium delivery using response surface methodology by full 32 factorial design. The effect of polymer-blend ratio (sodium alginate:TSP) and cross-linker (CaCl2) concentration on the drug encapsulation efficiency (DEE, %) and drug release from diclofenac sodium loaded TSP-alginate composite beads prepared by ionotropic gelation was optimized. The observed responses were coincided well with the predicted values by the experimental design. The DEE (%) of these beads containing diclofenac sodium was within the range between 72.23 ± 2.14 and 97.32 ± 4.03% with sustained in vitro drug release (69.08 ± 2.36-96.07 ± 3.54% in 10 h). The in vitro drug release from TSP-alginate composite beads containing diclofenac sodium was followed by controlled-release pattern (zero-order kinetics) with case-II transport mechanism. Particle size range of these beads was 0.71 ± 0.03-1.33 ± 0.04 mm. The swelling and degradation of the developed beads were influenced by different pH of the test medium. The FTIR and NMR analyses confirmed the compatibility of the diclofenac sodium with TSP and sodium alginate used to prepare the diclofenac sodium loaded TSP-alginate composite beads. The newly developed TSP-alginate composite beads are suitable for controlled delivery of diclofenac sodium for prolonged period.  相似文献   

9.
Modern microfabrication and microfluidic technologies offer new opportunities in the design and fabrication of miniaturized cell culture systems for online monitoring of living cells. We used laser micromachining and thermal bonding to fabricate an optically transparent, low-cost polymeric chip for long-term online cell culture observation under controlled conditions. The chip incorporated a microfluidic flow equalization system, assuring uniform perfusion of the cell culture media throughout the cell culture chamber. The integrated indium-tin-oxide heater and miniature temperature probe linked to an electronic feedback system created steady and spatially uniform thermal conditions with minimal interference to the optical transparency of the chip. The fluidic and thermal performance of the chip was verified by finite element modeling and by operation tests under fluctuating ambient temperature conditions. HeLa cells were cultured for up to 2 weeks within the cell culture chip and monitored using a time-lapse video recording microscopy setup. Cell attachment and spreading was observed during the first 10-20 h (lag phase). After approximately 20 h, cell growth gained exponential character with an estimated doubling time of about 32 h, which is identical to the observed doubling time of cells grown in standard cell culture flasks in a CO2 incubator.  相似文献   

10.
Sodium alginate was hydrophobically modified by coupling of polybutyl methacrylate onto the alginate. The polybutyl methacrylate was previously prepared through polymerization of butyl methacrylate in the presence of 2-amino-ethanethiol as a chain transfer agent. The structure of the product was characterized by Fourier-transformed infrared spectrometry, nuclear magnetic resonance (1HNMR) and thermogravimetry. The result of fluorescence analysis showed that the hydrophobicity of the modified alginate was obviously increased. The modified alginate conjugate was used for immobilization of bovine serum albumin in the presence of calcium chloride. In addition, the release behavior of the drug-loaded alginate in deionized water and Tris–HCl buffer solution (pH 7.2) was investigated. It was found that the modified sodium alginate possessed prolonged release behavior compared to unmodified sodium alginate, and it had potential application in controlled release as a drug carrier.  相似文献   

11.

Background

Microfluidics is an enabling technology with a number of advantages over traditional tissue culture methods when precise control of cellular microenvironment is required. However, there are a number of practical and technical limitations that impede wider implementation in routine biomedical research. Specialized equipment and protocols required for fabrication and setting up microfluidic experiments present hurdles for routine use by most biology laboratories.

Results

We have developed and validated a novel microfluidic device that can directly interface with conventional tissue culture methods to generate and maintain controlled soluble environments in a Petri dish. It incorporates separate sets of fluidic channels and vacuum networks on a single device that allows reversible application of microfluidic gradients onto wet cell culture surfaces. Stable, precise concentration gradients of soluble factors were generated using simple microfluidic channels that were attached to a perfusion system. We successfully demonstrated real-time optical live/dead cell imaging of neural stem cells exposed to a hydrogen peroxide gradient and chemotaxis of metastatic breast cancer cells in a growth factor gradient.

Conclusion

This paper describes the design and application of a versatile microfluidic device that can directly interface with conventional cell culture methods. This platform provides a simple yet versatile tool for incorporating the advantages of a microfluidic approach to biological assays without changing established tissue culture protocols.  相似文献   

12.
The aim of this study was to prepare biodegradable sustained release magnetite microspheres sized between 1 to 2 μm. The microspheres with or without magnetic materials were prepared by a W/O/W double emulsion solvent evaporation technique using poly(lactide-co-glycolide) (PLGA) as the biodegradable matrix forming polymer. Effects of manufacturing and formulation variables on particle size were investigated with non-magnetic microspheres. Microsphere size could be controlled by modification of homogenization speed, PLGA concentration in the oil phase, oil phase volume, solvent composition, and polyvinyl alcohol (PVA) concentration in the outer water phase. Most influential were the agitation velocity and all parameters that influence the kinematic viscosity of oil and outer water phase, specifically the type and concentration of the oil phase. The magnetic component yielding homogeneous magnetic microspheres consisted of magnetite nanoparticles of 8 nm diameter stabilized with a polyethylene glycole/polyacrylic acid (PEG/PAA) coating and a saturation magnetization of 47.8 emu/g. Non-magnetic and magnetic microspheres had very similar size, morphology, and size distribution, as shown by scanning electron microscopy. The optimized conditions yielded microspheres with 13.7 weight% of magnetite and an average diameter of 1.37 μm. Such biodegradable magnetic microspheres seem appropriate for vascular administration followed by magnetic drug targeting.  相似文献   

13.
Hepatic in vitro platforms ranging from multi-well cultures to bioreactors and microscale systems have been developed as tools to recapitulate cellular function and responses to aid in drug screening and disease model development. Recent developments in microfabrication techniques and cellular materials enabled fabrication of next-generation, advanced microphysiological systems (MPSs) that aim to capture the cellular complexity and dynamic nature of the organ presenting highly controlled extracellular cues to cells in a physiologically relevant context. Historically, MPSs have heavily relied on elastomeric materials in their manufacture, with unfavorable material characteristics (such as lack of structural rigidity) limiting their use in high-throughput systems. Herein, we aim to create a microfluidic bilayer model (microfluidic MPS) using thermoplastic materials to allow hepatic cell stabilization and culture, retaining hepatic functional phenotype and capturing cellular interactions. The microfluidic MPS consists of two overlapping microfluidic channels separated by a porous tissue-culture membrane that acts as a surface for cellular attachment and nutrient exchange; and an oxygen permeable material to stabilize and sustain primary human hepatocyte (PHH) culture. Within the microfluidic MPS, PHHs are cultured in the top channel in a collagen sandwich gel format with media exchange accomplished through the bottom channel. We demonstrate PHH culture for 7 days, exhibiting measures of hepatocyte stabilization, secretory and metabolic functions. In addition, the microfluidic MPS dimensions provide a reduced media-to-cell ratio in comparison with multi-well tissue culture systems, minimizing dilution and enabling capture of cellular interactions and responses in a hepatocyte-Kupffer coculture model under an inflammatory stimulus. Utilization of thermoplastic materials in the model and ability to incorporate multiple hepatic cells within the system is our initial step towards the development of a thermoplastic-based high-throughput microfluidic MPS platform for hepatic culture. We envision the platform to find utility in development and interrogation of disease models of the liver, multi-cellular interactions and therapeutic responses.  相似文献   

14.
Lim KH  Park J  Rhee SW  Yoon TH 《Cytometry. Part A》2012,81(8):691-697
A modified MTT protocol-based microfluidic image cytometry (μFIC) was performed to assess Cd(2+) induced cytotoxicity. The expanded capabilities of μFIC, such as in situ measurement, high-throughput, and multiparametric analysis of adherent cells under precisely controlled chemical environments of microfluidic channels, were demonstrated in this study. Multiparametric analysis of μFIC data has enabled us to categorize the progress of cell death into at least four different subgroups based on their morphology and metabolic activity. These advantages of the MTT-based μFIC as a simpler, cheaper, and faster in vitro cell-based assay tool have many implications in biomedical, pharmaceutical, toxicological, and biological application areas, and we propose this technique as a future high throughput-high content screening (HT-HCS) platform for cytotoxicity assays and drug screening.  相似文献   

15.
The uptake of microfluidics by the wider scientific community has been limited by the fabrication barrier created by the skills and equipment required for the production of traditional microfluidic devices. Here we present simple 3D printed microfluidic devices using an inexpensive and readily accessible printer with commercially available printer materials. We demonstrate that previously reported limitations of transparency and fidelity have been overcome, whilst devices capable of operating at pressures in excess of 2000 kPa illustrate that leakage issues have also been resolved. The utility of the 3D printed microfluidic devices is illustrated by encapsulating dental pulp stem cells within alginate droplets; cell viability assays show the vast majority of cells remain live, and device transparency is sufficient for single cell imaging. The accessibility of these devices is further enhanced through fabrication of integrated ports and by the introduction of a Lego®-like modular system facilitating rapid prototyping whilst offering the potential for novices to build microfluidic systems from a database of microfluidic components.  相似文献   

16.
Composite blend microbeads of sodium alginate (NaAlg) with sodium carboxymethyl cellulose (NaCMC) containing magnesium aluminum silicate (MAS) particles and enteric coated with chitosan have been prepared to achieve controlled release (CR) of amoxicillin in stomach environment. The composite beads have been characterized by X-ray diffraction (XRD) to study drug distribution, DSC for understanding thermal stability and Fourier transform infrared (FTIR) spectroscopy to investigate chemical interactions as well as to assess the structure of the drug-loaded formulations. Surface morphology of the beads was investigated by scanning electron microscopy (SEM). The size distribution of beads loaded with drug as studied by particle size analyzer was in the range of 745-889 μm. The beads exhibited quite widely varying encapsulation efficiencies from 52 to 92%. Equilibrium swelling of the beads measured in water and in vitro release of amoxicillin in pH 1.2 medium suggests that drug release depends on polymer blend composition, concentration of MAS and extent of enteric coating.  相似文献   

17.
Polymeric nanoparticles have emerged as a promising approach for drug delivery systems. We prepared chitosan (CS)/sodium alginate (SAL) polyelectrolyte complex nanoparticles (CS/SAL NPs) via a simple and mild ionic gelation method by adding a CS solution to a SAL solution, and investigated the effects of molecular weight of the added CS, and the SAL:CS mass ratio on the formation of the polyelectrolyte complex nanoparticles. The well-defined CS/SAL NPs with near-monodisperse particle size of about 160 nm exhibited a pH stable structure, and pH responsive properties with a negatively or positively charged surface. The so-called “electrostatic sponge” structure of the polyelectrolyte complex nanoparticles enhanced their drug-loading capacity towards the differently charged model drug molecules, and favored controlled release. We also found that the drug-loading capacity was influenced by the nature of the drugs and the drug-loading media, while drug release was affected by the solubility of the drugs in the drug-releasing media. The biocompatibility and biodegradability of the polyelectrolytes in the polyelectrolyte complex nanoparticles were maintained by ionic interactions. These results indicate that CS/SAL NPs can represent a useful technique for pH-responsive drug delivery systems.  相似文献   

18.
An innovative microfluidic platform for magnetic beads manipulation is introduced, consisting of novel microfabricated 3D magnetic devices positioned in a microfluidic chamber. Each magnetic device comprises of an embedded actuation micro-coil in various design versions, a ferromagnetic pillar, a magnetic backside plate and a sensing micro-coil. The various designs of the micro-coils enable efficient magnetic beads trapping and concentration in different patterns. The finite element analysis (FEA) results show a significant increase of the developed force on suspended magnetic beads when the magnetic pillar and backside plate were integrated into the device structure. These simulation results were confirmed experimentally by measuring the magnetic beads trapping ratios for the different designs and structures of the devices under continuous flow conditions. The trapping ratios and profiles were studied using beads counting, measuring the change of inductance with the sensing micro-coil and by image processing. The devices have efficiently demonstrated a controlled and localized magnetic beads trapping and concentration at small spatial locations for the first time. The new results shown in this study demonstrate the feasibility of efficiently using these original devices as key elements in complex bio-analysis systems.  相似文献   

19.
Paper is increasingly recognized as a portable substrate for cell culture, due to its low-cost, flexible, and special porous property, which provides a native cellular 3D microenvironment. Therefore, paper-based microfluidics has been developed for cell culture and biomedical analysis. However, the inability of continuous medium supply limits the wide application of paper devices for cell culture. Herein, a paper-based microfluidic device is developed with novel folded paper strips as wick-like structure, which is used for medium self-driven perfusion. The paper with patterns of hydrophilic channel, culture areas, and hydrophobic barrier could be easily fabricated through wax-printing. After printing, the hydrophilic paper strip at the periphery of the lower layer is then folded at 90° and extended into the medium container for continuous automatic supply of medium to the cell culture area. Tumor cells cultured in the paper device are tested for anti-cancer drug screening. Visualized cell viability and chemical sensitivity testing can be achieved by colorimetry combined with simple smartphone imaging, effectively reducing precision instrument dependence. The wick paper-based microfluidic device for cell culture endows the method the advantages of lower cost, ease-of-operation, miniaturization, and shows a great potential for large-scale cell culture, antibody drug production, and efficient screening.  相似文献   

20.
Nanoliter scale microbioreactor array for quantitative cell biology   总被引:14,自引:0,他引:14  
A nanoliter scale microbioreactor array was designed for multiplexed quantitative cell biology. An addressable 8 x 8 array of three nanoliter chambers was demonstrated for observing the serum response of HeLa human cancer cells in 64 parallel cultures. The individual culture unit was designed with a "C" shaped ring that effectively decoupled the central cell growth regions from the outer fluid transport channels. The chamber layout mimics physiological tissue conditions by implementing an outer channel for convective "blood" flow that feeds cells through diffusion into the low shear "interstitial" space. The 2 microm opening at the base of the "C" ring established a differential fluidic resistance up to 3 orders of magnitude greater than the fluid transport channel within a single mold microfluidic device. Three-dimensional (3D) finite element simulation were used to predict fluid transport properties based on chamber dimensions and verified experimentally. The microbioreactor array provided a continuous flow culture environment with a Peclet number (0.02) and shear stress (0.01 Pa) that approximated in vivo tissue conditions without limiting mass transport (10 s nutrient turnover). This microfluidic design overcomes the major problems encountered in multiplexing nanoliter culture environments by enabling uniform cell loading, eliminating shear, and pressure stresses on cultured cells, providing stable control of fluidic addressing, and permitting continuous on-chip optical monitoring.  相似文献   