首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
Previous fluorescence melting curve analysis (FMCA) used intercalating dyes, and this method has restricted application. Therefore, FMCA methods such as probe-based FMCA and molecular beacons were studied. However, the usual dual-labeled probes do not possess adequate fluorescence quenching ability and sufficient specificity, and molecular beacons with the necessary stem structures are hard to design. Therefore, we have developed a peptide nucleic acid (PNA)-based FMCA method. PNA oligonucleotide can have a much higher melting temperature (Tm) value than DNA. Therefore, short PNA probes can have adequate Tm values for FMCA, and short probes can have higher specificity and accuracy in FMCA. Moreover, dual-labeled PNA probes have self-quenching ability via single-strand base stacking, which makes PNA more favorable. In addition, this method can facilitate simultaneous identification of multiple DNA templates. In conventional real-time polymerase chain reaction (PCR), one fluorescence channel can identify only one DNA template. However, this method uses two fluorescence channels to detect three types of DNA. Experiments were performed with one to three different DNA sequences mixed in a single tube. This method can be used to identify multiple DNA sequences in a single tube with high specificity and high clarity.  相似文献   

3.
Peptide nucleic acid (PNA) is an artificially synthesized polymer. PNA oligomers show greater specificity in binding to complementary DNAs. Using this PNA, fluorescence melting curve analysis (FMCA) for dual detection was established. Genomic DNA of Mycoplasma fermentans and Mycoplasma hyorhinis was used as a template DNA model. By using one PNA probe, M. fermentans and M. hyorhinis could be detected and distinguished simultaneously in a single tube. The developed PNA probe is a dual‐labeled probe with fluorescence and quencher dye. The PNA probe perfectly matches the M. fermentans 16s rRNA gene, with a melting temperature of 72°C. On the other hand, the developed PNA probe resulted in a mismatch with the 16s rRNA gene of M. hyorhinis, with a melting temperature of 44–45°C. The melting temperature of M. hyorhinis was 27–28°C lower than that of M. fermentans. Due to PNA's high specificity, this larger melting temperature gap is easy to create. FMCA using PNA offers an alternative method for specific DNA detection. © 2015 American Institute of Chemical Engineers Biotechnol. Prog., 31:730–735, 2015  相似文献   

4.
Multiplexing genotyping technologies usually require as many probes as genetic variants. Oligonucleotides that span multiple loci--loci spanning probes (LSProbes)--hybridize to two or more noncontiguous DNA sequences present in a template and can be used to analyze multiple variants simultaneously. The intervening template sequence, omitted in the LSProbe, creates a bulge-loop during binding. Melting temperatures of the probe, monitored by fluorescence reading are specific to the presence or absence of the mutations. We previously described LSProbes as a molecular haplotyping tool and apply here the principle to genotype simultaneously three mutations of the beta-globin gene responsible for the corresponding hemoglobinopathies. Analysis with both labeled and unlabeled LSProbes demonstrate that the four possible alleles studied (WT, HbS, HbC, and HbE) are identifiable by the specific melting temperatures of the LSProbes. This demonstrates that, in addition to their haplotyping capabilities, LSProbes are able to genotype in a single step, loci 58 nucleotides apart.  相似文献   

5.
6.
Multiplex quantitative PCR based on novel design of fluorescent primers is described. Fluorogenic primers are labeled with a single fluorophore on a base close to the 3′ end with no quencher required. A tail of 5–7 nt is added to the 5′ end of the primer to form a blunt-end hairpin when the primer is not incorporated into a PCR product. This design provides a low initial fluorescence of the primers that increases up to 8-fold upon formation of the PCR product. The hairpin oligonucleotides (ΔG from 1.6 to –5.8 kcal/mol) may be as efficient as linear primers and provide additional specificity to the PCR by preventing primer-dimers and mispriming. Multiple fluorogenic primers were designed by specialized software and used for real-time quantitation of c-myc and IL-4 cDNAs in the presence of reference genes such as β-actin, GAPDH and 18S rRNA. Targets of 10107 copies were detected with precision in PCR using FAM-labeled primers for variable genes and JOE-labeled primers for the reference genes. This method was also used to detect single nucleotide polymorphism of the human retinal degeneration gene by allele-specific PCR with end-point detection using a fluorescent plate reader or a UV-transilluminator. We conclude that fluorogenic mono-labeled primers are an efficient and cost-effective alternative to FRET-labeled oligonucleotides.  相似文献   

7.
Wu Z  Yuan H  Zhang X  Liu W  Xu J  Zhang W  Guan M 《PloS one》2011,6(10):e26534

Background

JAK2 V617F, a somatic point mutation that leads to constitutive JAK2 phosphorylation and kinase activation, has been incorporated into the WHO classification and diagnostic criteria of myeloid neoplasms. Although various approaches such as restriction fragment length polymorphism, amplification refractory mutation system and real-time PCR have been developed for its detection, a generic rapid closed-tube method, which can be utilized on routine genetic testing instruments with stability and cost-efficiency, has not been described.

Methodology/Principal Findings

Asymmetric PCR for detection of JAK2 V617F with a 3′-blocked unlabeled probe, saturate dye and subsequent melting curve analysis was performed on a Rotor-Gene® Q real-time cycler to establish the methodology. We compared this method to the existing amplification refractory mutation systems and direct sequencing. Hereafter, the broad applicability of this unlabeled probe melting method was also validated on three diverse real-time systems (Roche LightCycler® 480, Applied Biosystems ABI® 7500 and Eppendorf Mastercycler® ep realplex) in two different laboratories. The unlabeled probe melting analysis could genotype JAK2 V617F mutation explicitly with a 3% mutation load detecting sensitivity. At level of 5% mutation load, the intra- and inter-assay CVs of probe-DNA heteroduplex (mutation/wild type) covered 3.14%/3.55% and 1.72%/1.29% respectively. The method could equally discriminate mutant from wild type samples on the other three real-time instruments.

Conclusions

With a high detecting sensitivity, unlabeled probe melting curve analysis is more applicable to disclose JAK2 V617F mutation than conventional methodologies. Verified with the favorable inter- and intra-assay reproducibility, unlabeled probe melting analysis provided a generic mutation detecting alternative for real-time instruments.  相似文献   

8.
The TaqMan probes that have been long and effectively used in real-time polymerase chain reaction (PCR) may also be used in DNA melting analysis. We studied some factors affecting efficiency of the approach such as (i) number of asymmetric PCR cycles preceding DNA melting analysis, (ii) choice of fluorophores for the multiplex DNA melting analysis, and (iii) choice of sense or antisense TaqMan probes for optimal resolution of wild-type and mutant alleles. We also determined ΔTm (i.e., the temperature shift of a heteroduplex relative to the corresponding homoduplex) as a means of preliminary identification of mutation type. In experiments with serial dilution of mutant KRAS DNA with wild-type DNA, the limit of detection of mutant alleles was 1.5–3.0%. Using DNA from both tumor and formalin-fixed paraffin-embedded tissues, we demonstrated a high efficiency of TaqMan probes in mono- and multiplex mutation scanning of KRAS, NRAS (codons 12, 13, and 61), and BRAF (codon 600) genes. This cost-effective method, which can be applied to practically any mutation hot spot in the human genome, combines simplicity, ease of execution, and high sensitivity—all of the qualities required for clinical genotyping.  相似文献   

9.
W Xiao  D Stern  M Jain  C G Huber  P J Oefner 《BioTechniques》2001,30(6):1332-1338
Denaturing high-performance liquid chromatography (DHPLC) is a sensitive, robust, and operationally inexpensive method for the detection of single-base substitutions and small deletions and insertions. To increase sample throughout, we have developed a multiplexing strategy using fluorophores to distinguish different PCR products. The system combines recent advances in the synthesis of monolithic poly(styrene-divinylbenzene) capillary columns with four-color confocal argon ion laser-induced fluorescence detection. Depending on the change in retention caused by the fluorophores, adjustments in the analysis temperature may be required to ensure the maximum mutation detection sensitivity.  相似文献   

10.
Currently, in real-time PCR, one often has to choose between using a sequence-specific probe and a nonspecific double-stranded DNA (dsDNA) binding dye for the detection of amplified DNA products. The sequence-specific probe has the advantage that it only detects the targeted product, while the nonspecific dye has the advantage that melting curve analysis can be performed after completed amplification, which reveals what kind of products have been formed. Here we present a new strategy based on combining a sequence-specific probe and a nonspecific dye, BOXTO, in the same reaction, to take the advantage of both chemistries. We show that BOXTO can be used together with both TaqMan probes and locked nucleic acid (LNA) probes without interfering with the PCR. The probe signal reflect formation of target product, while melting curve analysis of the BOXTO signal reveals primer-dimer formation and the presence of any other anomalous products.  相似文献   

11.
This report describes a new genotyping method capable of detecting low-abundant point mutations in a homogeneous, separation-free format. The method is based on integration of oligonucleotide ligation with a semiconductor quantum dot (QD)-mediated two-color fluorescence coincidence detection scheme. Surface-functionalized QDs are used to capture fluorophore-labeled ligation products, forming QD-oligonucleotide nanoassemblies. The presence of such nanoassemblies and thereby the genotype of the sample is determined by detecting the simultaneous emissions of QDs and fluorophores that occurs whenever a single nanoassembly flows through the femtoliter measurement volume of a confocal fluorescence detection system. The ability of this method to detect single events enables analysis of target signals with a multiple-parameter (intensities and count rates of the digitized target signals) approach to enhance assay sensitivity and specificity. We demonstrate that this new method is capable of detecting zeptomoles of targets and achieve an allele discrimination selectivity factor >105.  相似文献   

12.
13.
Ehlers-Danlos syndrome, vascular type (vEDS) (MIM #130050) is an autosomal dominant disorder caused by type III procollagen gene (COL3A1) mutations. Most COL3A1 mutations are detected by using total RNA from patient-derived fibroblasts, which requires an invasive skin biopsy. High-resolution melting curve analysis (hrMCA) has recently been developed as a post-PCR mutation scanning method which enables simple, rapid, cost-effective, and highly sensitive mutation screening of large genes. We established a hrMCA method to screen for COL3A1 mutations using genomic DNA. PCR primers pairs for COL3A1 (52 amplicons) were designed to cover all coding regions of the 52 exons, including the splicing sites. We used 15 DNA samples (8 validation samples and 7 samples of clinically suspected vEDS patients) in this study. The eight known COL3A1 mutations in validation samples were all successfully detected by the hrMCA. In addition, we identified five novel COL3A1 mutations, including one deletion (c.2187delA) and one nonsense mutation (c.2992C>T) that could not be determined by the conventional total RNA method. Furthermore, we established a small amplicon genotyping (SAG) method for detecting three high frequency coding-region SNPs (rs1800255:G>A, rs1801184:T>C, and rs2271683:A>G) in COL3A1 to differentiate mutations before sequencing. The use of hrMCA in combination with SAG from genomic DNA enables rapid detection of COL3A1 mutations with high efficiency and specificity. A better understanding of the genotype–phenotype correlation in COL3A1 using this method will lead to improve in diagnosis and treatment.  相似文献   

14.
Factor XII (FXII) level is an important intermediate phenotype associated with thrombotic disease. The 46C --> T transition in the exon 1 of the Factor XII (F12) gene is a significant, prevalent, and independent genetic risk factor for thrombotic disease. It is also associated with interindividual variation of plasma FXII zymogen levels. The aims of this study were to develop a rapid, reproducible, and easy method for 46C --> T genotyping and to compare its reliability with the classical endonuclease digestion methodology. DNA samples from 100 subjects were genotyped for the 46C --> T transition using the classical endonuclease digestion method with Sfna I. The genotypes of three of them (each with a different 46C R T genotype) were confirmed by direct sequencing analysis. We then set out to construct a LightCycler PCR protocol to detect the 46C --> T polymorphism. This protocol was designed to combine a rapid-cycle polymerase chain reaction (PCR) with an allele-specific fluorescent probe melting for mutation detection. In the three sequenced samples, as well as in the remaining 97, the LightCycler PCR procedure unambiguously resulted in the same genotype previously observed by sequencing and endonuclease digestion. Characteristic fluorescent curves were obtained for each genotype; the first derivative of these curves had a maximum at an apparent hybridization temperature (Tm) that was specific for each probe/allele duplex. The whole process took less than 40 min. Thus, if this method is used with a rapid DNA extraction, the genotypes would be obtained within 60 min after receiving a blood sample. In conclusion, the technique presented allows for easy, reliable, and rapid detection of this polymorphism, and is suitable for typing both small and large numbers of DNA samples.  相似文献   

15.
Fu G  Miles A  Alphey L 《PloS one》2012,7(1):e30340
Probe-based PCR is widely used for SNP (single nucleotide polymorphism) genotyping and pathogen nucleic acid detection due to its simplicity, sensitivity and cost-effectiveness. However, the multiplex capability of hydrolysis probe-based PCR is normally limited to one target (pathogen or allele) per fluorescence channel. Current fluorescence PCR machines typically have 4–6 channels. We present a strategy permitting the multiplex detection of multiple targets in a single detection channel. The technique is named Multiplex Probe Amplification (MPA). Polymorphisms of the CYP2C9 gene (cytochrome P450, family 2, subfamily C, polypeptide 9, CYP2C9*2) and human papillomavirus sequences HPV16, 18, 31, 52 and 59 were chosen as model targets for testing MPA. The allele status of the CYP2C9*2 determined by MPA was entirely concordant with the reference TaqMan® SNP Genotyping Assays. The four HPV strain sequences could be independently detected in a single fluorescence detection channel. The results validate the multiplex capacity, the simplicity and accuracy of MPA for SNP genotyping and multiplex detection using different probes labeled with the same fluorophore. The technique offers a new way to multiplex in a single detection channel of a closed-tube PCR.  相似文献   

16.
The uses of multiplex detection methodologies are dramatically increasing as a means to increase sample throughput and to demonstrate quantitative differences between multiple targets in gene or protein expression analysis. In this study, we investigate the application of multiplex fluorescent detection for three proteins on the same Western blot using a laser-scanning imaging system, the Bio-Rad Molecular Imager FX. We show that independent detection and quantitation of multiple targets is achievable with little or no correction for fluorescent crosstalk by using fluorescent tags preferentially excited with different laser lines and detected at wavelengths that minimize fluorescence crosstalk. We demonstrate that the use of fluorescent detection methods can provide a tenfold greater quantifiable range but with two- to fourfold less sensitivity than chemiluminescent detection methodologies. Two examples of three-color multiplex detection using FITC-, Cy3- and Cy5-conjugated probes on Western blots are provided to demonstrate applications of this approach.  相似文献   

17.
Direct determination of the association of multiple genetic polymorphisms, or haplotyping, in individual samples is challenging because of chromosome diploidy. Here, we describe the ability of hybridization probes, commonly used as genotyping tools, to establish single nucleotide polymorphism (SNP) haplotypes in a single step. Three haplotypes found in the beta 2-adrenergic receptor (β2AR) gene and characterized by three different SNPs combinations are presented as examples. Each combination of SNPs has a unique stability, recorded by its melting temperature, even when intervening sequences from the template must loop out during probe hybridization. In the course of this study, two haplotypes in β2AR not described previously were discovered. This approach provides a tool for molecular haplotyping that should prove useful in clinical molecular genetics diagnostics and pharmacogenetic research where methods for direct haplotyping are needed.  相似文献   

18.
Automation is essential for rapid genetic-based mutation analysis in clinical laboratory to screen a large number of DNA samples. We propose in this report an automatic process using Beckman Coulter P/ACE™ capillary electrophoresis (CE) with laser-induced fluorescence (LIF) system to detect a single-point mutation in the codon 12 of human K-ras gene. Polymerase chain reaction (PCR) using a fluorescently labeled reverse primer and a plain forward primer to specifically amplify a selected 50 bp DNA fragment in human K-ras gene. The amplified DNA is placed on the sample tray of the CE system with a pre-programmed step for single-strand conformation polymorphism (SSCP) analysis. Sample injection and denaturation processes are performed online along with separation and real-time data analysis. The concept of automation for rapid DNA mutation analysis using CE-LIF system for SSCP is presented.  相似文献   

19.
Rapid competitive PCR using melting curve analysis for DNA quantification.   总被引:5,自引:0,他引:5  
S Al-Robaiy  S Rupf  K Eschrich 《BioTechniques》2001,31(6):1382-6, 1388
A rapid competitive PCR method was developed to quantify DNA on the LightCycler. It rests on the quantitative information contained in the melting curves obtained after amplification in the presence of SYBR Green I. Specific hybridization probes are not required. Heterologous internal standards sharing the same primer binding sites and having different melting temperatures to the natural PCR products were used as competitors. After a co-amplification of known amounts of the competitor with a DNA-containing sample, the target DNA can be quantified from the ratio of the melting peak areas of competitor and target products. The method was developed using 16S rDNA fragments from Streptococcus mutans and E. coli and tested against existing PCR-based DNA quantification procedures. While kinetic analysis of real-time PCR is well established for the quantification of pure nucleic acids, competitive PCR on the LightCycler based on an internal standardization was found to represent a rapid and sensitive alternative DNA quantification method for analysis of complex biological samples that may contain PCR inhibitors.  相似文献   

20.
Here we describe the properties of a novel class of oligonucleotide probes capable of sensitive hybridization-triggered fluorescence. These fluorogenic probes, known commercially as MGB Eclipse probes, are characterized by having a conjugated minor groove binder (MGB) ligand at the 5'-end and a fluorophore at the 3'-end. Additionally, they have an efficient quencher moiety at the 5'-end that is useful with a wide variety of fluorescent dyes. Fluorescence of the single-stranded MGB Eclipse probe is efficiently quenched by the interaction of the terminal dye and quencher groups when not hybridized. Upon hybridization to a complementary target, the MGB molecule folds into duplex and hyper-stabilizes it, allowing the use of shorter, more specific probe sequences. The 5'-MGB-quencher group also prevents nuclease digestion by Taq DNA polymerase during PCR. Because of the hybridization-triggered fluorescence and the excellent specificity imparted by the MGB, these 5'-MGB Eclipse probes have great versatility for real-time PCR applications. The high sensitivity and specificity are illustrated using single nucleotide polymorphism detection, viral load determination, and gene expression analysis.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号