首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 328 毫秒
1.
Recent laboratory and epidemiological results have stimulated interest in the hypothesis that human beings may exhibit biological responses to magnetic and/or electric field transients with frequencies in the range between 100 Hz and 100 kHz. Much can be learned about the response of a system to a transient stimulation by understanding its response to sinusoidal disturbances over the entire frequency range of interest. Thus, the main effort of this paper was to compare the strengths of the electric fields induced in homogeneous ellipsoidal models by uniform 100 Hz through 100 kHz electric and magnetic fields. Over this frequency range, external electric fields of about 25–2000 V/m (depending primarily on the orientation of the body relative to the field) are required to induce electric fields inside models of adults and children that are similar in strength to those induced by an external 1 μT magnetic field. Additional analysis indicates that electric fields induced by uniform external electric and magnetic fields and by the nonuniform electric and magnetic fields produced by idealized point sources will not differ by more than a factor of two until the sources are brought close to the body. Published data on electric and magnetic field transients in residential environments indicate that, for most field orientations, the magnetic component will induce stronger electric fields inside adults and children than the electric component. This conclusion is also true for the currents induced in humans by typical levels of 60 Hz electric and magnetic fields in U.S. residences. Bioelectromagnetics 18:67–76, 1997. © 1997 Wiley-Liss, Inc.  相似文献   

2.
Power-frequency electric and magnetic fields are known to exhibit marked temporal variation, yet in the absence of clear biological indications, the most appropriate summary indices for use in epidemiologic studies are unknown. In order to assess the statistical patterns among candidate indices, data on 4383 worker-days for magnetic fields and 2082 worker-days for electric fields collected for the Electric and Magnetic Field Project for Electric Utilities using the EMDEX meter [Bracken (1990): Palo Alto, CA: Electric Power Research Institute] were analyzed. We examined correlations at the individual and job title group levels among indices of exposure to both electric and magnetic fields, including the arithmetic mean, geometric mean, median, 20th and 90th percentiles, time above lower cutoffs of 20 V/m and 0.2 μT, and time above higher cutoffs of 100 V/m and 2.0 μT. For both electric and magnetic fields, the arithmetic mean was highly correlated with the 90th percentile; moderately correlated with the geometric mean, median, and lower and higher cutoff scores; and weakly correlated with the 20th percentile. Electric and magnetic field indices were generally weakly correlated with one another. Rank-order correlation coefficients were consistently greater than product-moment correlation coefficients. Job title group summary scores showed higher correlations among electric field indices and magnetic field indices and between electric and magnetic field indices than was found for individual worker-days, with only the 20th percentile clearly independent of the others. These results suggest that individuals' exposures are adequately characterized by a measure of central tendency for electric and magnetic fields, such as the arithmetic or geometric mean, and an indicator of a lower threshold or cutoff for each field type, such as the 20th percentile or proportion of time above 20 V/m or 0.2 μT. A single measure of central tendency for each type of field appears to be adequate when exposures are assessed at the job title level. © 1994 Wiley-Liss, Inc.  相似文献   

3.
Auditory electric and magnetic P50(m), N1(m) and MMN(m) responses to standard, deviant and novel sounds were studied by recording brain electrical activity with 25 EEG electrodes simultaneously with the corresponding magnetic signals measured with 122 MEG gradiometer coils. The sources of these responses were located on the basis of the MEG responses; all were found to be in the supratemporal plane. The goal of the present paper was to investigate to what degree the source locations and orientations determined from the magnetic data account for the measured EEG signals. It was found that the electric P50, N1 and MMN responses can to a considerable degree be explained by the sources of the corresponding magnetic responses. In addition, source-current components not detectable by MEG were shown to contribute to the measured EEG signals.  相似文献   

4.
A theoretical analysis of electric and magnetic fields of the heart, based solely upon the scalar multipole expansion, is carried out in order to gain an insight into the interrelation of the data contained in electro- and magnetocardiological measurements. The usual multipole expansion is applied for the electric field, however corresp[nding equivalent multipoles are formulated as idealized generators, having not only flow sources, but also vortex sources of the field. Furthermore, the magnetic field in a homogeneous infinite volume conductor is expressed as a sum of two series, the first being the usual multipole expansion of the nonvortex component of the magnetic field, and the second being a sequence of magnetic fields set up by the aforementioned electric multipole generators reduced to axial form. The former term is uniquely defined by the electric multipole components, but the latter reflects properties of the cardiogenerator that can be revealed only by means of magnetic measurements. Features of the electric and magnetic multipole components as integral characteristics of the cardiogenerator are discussed and concepts of the magnetic centre and magnetic axis of the cardiogenerator are proposed. The analysis is illustrated by examples of simple generator configurations.  相似文献   

5.
The neurophysiologic effects of combined 60-Hz electric (E) and magnetic (B) fields, of magnitudes comparable to those produced by high-voltage powerlines, were investigated in 10 monkeys (Macaca nemestrina). Six animals (experimental group) were each exposed to three different levels of E and B fields: 3 kV/m and 0.1 G, 10 kV/m and 0.3 G, and 30 kV/m and 0.9 G. Field exposures were preceded and followed by sham exposures, during which factors of field generation were present (e.g., heat, vibration, noise, etc.) without E and B fields. Each of the five segments (i.e., the three exposure segments and the initial and final sham exposure segments) lasted 3 weeks. Animals were exposed for 18 h/day (fields on at 1600 h, off at 1000 h). Four other animals (external control group) were given sham exposure for the entire 15-week period. Auditory, visual, and somatosensory evoked potentials were recorded twice a week, during the daily 6-h field-off period. E- and B-field exposure had no effect on the early or mid-latency evoked potential components, suggesting that exposure at these levels has no effect on peripheral or central sensory afferent pathways. However, there was a statistically significant decrease in the amplitudes of late components of the somatosensory evoked potential during the 10kV/m and 0.3 G, and 30 kV/m and 0.9 G exposure levels. This result is possibly related to the opiate antagonist effect of electromagnetic field exposure reported by others.  相似文献   

6.
Visual evoked magnetic fields due to pattern reversal stimuli were measured in 5 normal subjects using a helmet-shaped 66 channel magnetoencephalography system linked to MRI. The magnetic topography of the prominent 100 ms response (P100m) evoked by full-field visual showed a double-dipole pattern in the occipital areas of all subjects. Right or left half-field stimuli and upper or lower quadrant-field stimuli evoked a single-dipole pattern in the contralateral occipital area. The P100m sources were when localized using a current dipole model and superimposed on MRI images of each subject. The visual cortex was morphologically variable among the subjects, but the P100m dipoles were all localized at the lateral bottom of the calcarine fissure. Moreover, these P100m dipoles had similar orientations for both half- or quadrant-field stimuli. These results suggest that the P100m is located in a smaller part of the striate cortex than previously reported.  相似文献   

7.
We have recorded early components of somatosensory evoked magnetic fields with a sensitive 7-channel first-order gradiometer using a wide recording passband (0.05–2000 Hz) and high sampling frequency (8000 Hz). The left median nerve was stimulated at the wrist and responses were recorded over the right hemisphere. The responses typically consisted of a N20m peaking at 18–20 msec, a small P22m peaking at 21–23 msec and a P27m peaking at 29–31 msec. The topography of N20m could be explained by a tangential current dipole in the posterior wall of the central sulcus (probably in area 3b). The equivalent dipoles of P27m were located on average 10 mm antero-medially to the sources of N20m. This suggests that P27m may get a contribution from the anterior wall of the central sulcus. An increase of stimulus repetition rate from 2 to 5 Hz decreased the amplitude of P27m more than that of N20m, which implies that these two deflactions are generated by different neural netwoks.  相似文献   

8.
There are two possible mechanisms of effects of large electric fields on animals, one caused by the electric field at the body surface and the other caused by the electric current induced inside the body. The purpose of the present experiments was to investigate the former possibility by recording action potentials from afferent fibers innervating various sensory receptors in the cat's hindlimb. Cat hairs were attracted to the upper electrode when exposed to DC electric fields of 180 kV/m or greater, and action potentials were evoked in the afferent fibers innervating G1, G2, and down hair receptors. No action potentials were evoked in afferent fibers innervating type I, type II, field receptors, muscle spindles, or joint receptors. These results indicate that a strong DC electric field induced movement of the hairs, eventually evoked excitation of the hair receptors, but that other receptors located under the skin were not influenced by electric field exposure.  相似文献   

9.
In adherent and motile neutrophils NAD(P)H concentration, flavoprotein redox potential, and production of reactive oxygen species and nitric oxide, are all periodic and exhibit defined phase relationships to an underlying metabolic oscillation of approximately 20 s. Utilizing fluorescence microscopy, we have shown in real-time, on the single cell level, that the system is sensitive to externally applied periodically pulsed weak magnetic fields matched in frequency to the metabolic oscillation. Depending upon the phase relationship of the magnetic pulses to the metabolic oscillation, the magnetic pulses serve to either increase the amplitude of the NAD(P)H and flavoprotein oscillations, and the rate of production of reactive oxygen species and nitric oxide or, alternatively, collapse the metabolic oscillations and curtail production of reactive oxygen species and nitric oxide. Significantly, we demonstrate that the cells do not directly respond to the magnetic fields, but instead are sensitive to the electric fields which the pulsed magnetic fields induce. These weak electric fields likely tap into an endogenous signaling pathway involving calcium channels in the plasma membrane. We estimate that the threshold which induced electric fields must attain to influence cell metabolism is of the order of 10(-4) V/m.  相似文献   

10.
The goal of this study was to address some of the factors that contribute to the human ability to detect the presence of weak electric fields generated by direct current (DC) and alternating current (AC) sources. An exposure chamber allowed us to expose a limited surface of the body (forearm and hand) to DC fields of up to 65 kV/m and AC fields up to a maximum of 35 kV/m (frequency 60 Hz). Perception was examined using a staircase procedure and a rating procedure derived from signal detection theory. Sixteen subjects participated in the experiments, and none detected the local DC fields. In contrast, 9/16 subjects were sensitive to local AC electric fields, although detection thresholds (index of sensitivity, d' = 1.0) were widely variable between subjects. When regional exposure was limited to the dorsal forearm, performance was similar to that seen when the forearm and hand were exposed. In contrast, subjects did not reliably detect the AC electric fields when exposure was limited to the hand (either hairy or glabrous skin), although a minority of subjects (3/9) showed some evidence of detecting fields presented to the glabrous palm. Subjects were unable to detect AC electric fields when the hair was removed from the forearm and hand, suggesting that the evoked sensation is mainly dependent on movement of hair located in the exposed region.  相似文献   

11.
Results are presented of an investigation on electric and magnetic fields leaking from inductive (magnetic) heaters that are used for thermal processing of high-power electron tubes and lasers in an industrial plant. Measurements of electric and magnetic fields were done using both commercially available and laboratory-developed instrumentation. Isotropic H-field sensors were developed to allow quantitative evaluation of high-intensity magnetic fields. Ten induction heaters with nominal A.C. power ranging from 2.5 kW to 15 kW and operating at frequencies between 300 kHz and 790 kHz were surveyed. Electric field strengths up to 8 kV/m and magnetic field strengths up to 20 A/m were measured.  相似文献   

12.
The electric field of evoked potentials developing in the rabbit superior colliculus in response to single electrical stimulation of the optic nerve was investigated. Regions of localization of sources and sinks of synaptic current creating the evoked potential were discovered by the current source density analysis method. Sinks with the shortest latency appeared in the depth of str. griseum superficiale, after which activity created by two dipoles appeared: The sink of one dipole was located in the upper part of str. griseum superficiale, the sink of the other in the lower part. The sinks thus found corresponded in their temporal characteristics and location to the principal components of the combined evoked potential. On the basis of these data the order of activation of the various systems of fibers and synapses responsible for evoked potential formation can be traced.  相似文献   

13.
Ding GR  Wake K  Taki M  Miyakoshi J 《Life sciences》2001,68(9):1041-1046
Previously, we reported that exposure to extremely low frequency magnetic field (400 mT) increased in hypoxanthine-guanine phosphoribosyl transferase (HPRT) gene mutations. However, it is unclear these mutations were induced by magnetic field (MF), electric field (EF), or both. To explore this question, a new exposure apparatus for EF was manufactured. We observed an increase in HPRT gene mutations in Chinese hamster ovary (CHO) cells after exposure to EF (10 V/m, 60 Hz) for 10 h. The mutant frequency by EF-exposure was an approximate 2-fold of that by sham-exposure. Our data suggest that the mutations induced by exposure of cells to the variable magnetic field at 400 mT may be, in part, due to the induced EF.  相似文献   

14.
Somatosensory evoked potentials (SEPs) to median nerve and finger stimulation were analyzed by means of spatio-temporal dipole modelling combined with 3D-NMR tomography in 8 normal subjects. The early SEPs were modelled by 3 equivalent dipoles located in the region of the brain-stem (B) and in the region of the contralateral somatosensory cortex (T and R). Dipole B explained peaks P14 and N18 at the scalp. Dipole T was tangentially oriented and explained the N20-P20, dipole R was radially oriented and modelled the P22. The tangential dipole sources T were located within a distance of 6 mm on the average and all were less than 9 mm from the posterior bank of the central sulcus. In 6 subjects the tangential sources related to finger stimulation arranged along the central sulcus according to the known somatotopy. The radial sources did not show a consistent somatotopic alignment across subjects. We conclude that the combination of dipole source analysis and 3D-NMR tomography is a useful tool for functional localization within the human hand somatosensory cortex.  相似文献   

15.
We recorded middle-latency auditory evoked magnetic fields from 9 healthy subjects with a 122-channel whole-head SQUID gradiometer. The stimuli were click triplets, 2.5 msec in total duration, delivered alternately to the two ears once every 333 msec. Contralateral clicks elicited P30m responses in 16 and P50m responses in 12 out of 18 hemispheres studied; ipsilateral clicks did so in 7 and 13 hemispheres, respectively. The field patterns were satisfactorily explained by current dipoles in 16 and 4 hemispheres for contra- and ipsilateral P30m, and in 4 and 10 hemispheres for contra- and ipsilateral P50m. The peak latencies of P30m and P50m were not affected by stimulation side. The results show that middle-latency auditory evoked responses receive a strong contribution from auditory cortical structures, and that differences of input latency to cortical auditory areas, evaluated from MLAEF latencies, do not explain the latency differences seen in late auditory evoked fields to contralateral vs. ipsilateral stimulation.  相似文献   

16.
Using a crossover experimental design, we evaluated our earlier findings that exposure to a 30 kV/m, 60 Hz electric field for 12 hours per day, 7 days per week for 6 weeks produced significant changes in the performance rates of social behaviors among young adult male baboons. In the crossover experiment, the former control group was exposed to a 30 kV/m, 60 Hz electric field for 3 weeks. Only an extremely small, incidental magnetic field was generated by the exposure apparatus. We found that electric-field exposure again produced increases in the performance rates that index Passive Affinity, Tension, and Stereotypy. These findings, combined with results from our other electric-field experiments, indicate that exposure to strong electric fields, in the absence of associated magnetic fields, consistently produces effects that are expressed as increases in rates of performance of social behaviors in young adult male baboons.  相似文献   

17.
The effects of 50 Hz sinusoidal electric currents and magnetic fields on the Gram-positive skin bacterium Propionibacterium acnes were investigated. Intracellular free calcium ([Ca(2+)](i)), intracellular pH (pH(i)), and cell viability were examined, based on their relevance to ELF field studies and on previous studies conducted on P. acnes (UVA irradiation, photosensitization using porphyrin-based sensitizers, and broad-band red light). The [Ca(2+)](i) and the pH(i) were measured spectrofluorimetrically using the fluorescent probes fura-2 and BCECF, respectively. Sham-exposed controls were used to assess the field exposed samples. Cell suspensions were exposed to 50 Hz, 0.2 mT sinusoidal magnetic fields generated by using Helmholtz coils for up to 30 min. The estimated maximum induced electric field was 0.2 mV/m. Changes in [Ca(2+)](i) and cell viability were not detected. Ag/AgCl electrodes were used to expose cell suspensions to 50 Hz sinusoidal electric currents. The current densities were in the range 0.015-1500 A/m(2) (corresponding electric fields congruent with0.01-1000 V/m). Changes in [Ca(2+)](i) were not observed after current exposure. Current densities of 800 A/m(2) (electric field E congruent with550 V/m) were required for a 50% reduction in cell viability. Current densities greater than 800 A/m(2) were required for a reduction in pH(i). However, a pH gradient across the cell membrane (inside alkaline) was maintained even when exposure resulted in less than 0. 2% survival (1400 A/m(2), E congruent with950 V/m). Thus, dissipation of the pH gradient across the cell membrane and changes in [Ca(2+)](i) were not a consequence of cell inactivation by 50 Hz electric currents. This is in contrast to inactivation of P. acnes by UVA irradiation or photosensitization, where such changes have been obtained.  相似文献   

18.
A method using a DC servo motor is described to produce brisk angular movements at finger interphalangeal joints in humans. Small passive flexions of 2° elicited sizable somatosensory evoked potentials (SEPs) starting with a contralateral positive P34 parietal response thought to reflect activation of a radial equivalent dipole generator in area 2 which receives joint inputs. By contrast, electric stimulation of tactile (non-joint) inputs from the distal phalanx evoked the usual contralateral negative N20 reflecting a tangential equivalent dipole generator in area 3b. Finger joint inputs also evoked a precentral positivity equivalent to the P22 of motor area 4, and a large frontal negativity equivalent to N30. It is suggested that natural stimulation allows human SEP components to the differentiated in conjunction with distinct cortical somatotopic projections.  相似文献   

19.

Background

We report the case of a chronic stroke patient (62?months after injury) showing total absence of motor activity evoked by transcranial magnetic stimulation (TMS) of spared regions of the left motor cortex, but near-to-complete recovery of motor abilities in the affected hand.

Case presentation

Multimodal investigations included detailed TMS based motor mapping, motor evoked potentials (MEP), and Cortical Silent period (CSP) as well as functional magnetic resonance imaging (fMRI) of motor activity, MRI based lesion analysis and Diffusion Tensor Imaging (DTI) Tractography of corticospinal tract (CST). Anatomical analysis revealed a left hemisphere subinsular lesion interrupting the descending left CST at the level of the internal capsule. The absence of MEPs after intense TMS pulses to the ipsilesional M1, and the reversible suppression of ongoing electromyographic (EMG) activity (indexed by CSP) demonstrate a weak modulation of subcortical systems by the ipsilesional left frontal cortex, but an inability to induce efficient descending volleys from those cortical locations to right hand and forearm muscles. Functional MRI recordings under grasping and finger tapping patterns involving the affected hand showed slight signs of subcortical recruitment, as compared to the unaffected hand and hemisphere, as well as the expected cortical activations.

Conclusions

The potential sources of motor voluntary activity for the affected hand in absence of MEPs are discussed. We conclude that multimodal analysis may contribute to a more accurate prognosis of stroke patients.  相似文献   

20.
We recorded somatosensory evoked potentials (SEPs) in scalp EEGs during stimulation of the median nerve, the ulnar nerve and the individual digits in 3 normal subjects and in 1 epilepsy patients. In this patient we also measured SEPs from chronically indwelling subdural grid electrodes during electrocorticography (ECoG). We applied dipole modelling techniques to study the 3-dimensional intracerebral locations and time activities of the neuronal sources underlying stimulation of different peripheral receptive fields. The sources underlying median nerve SEPs were located an average of 10.8 mm lateral inferior to those underlying ulnar nerve SEPs. Digit SEP sources showed a somatotopic arrangement from lateral inferior to medial superior in the order thumb, index finger, middle finger, ring finger and little finger, with some overlap or reversal for adjacent digits. The average distance between thumb and little finger was 12.5 mm. Thumb, index finger and middle finger were clustered around median nerve cortical representation, whereas ring finger and little finger were arranged around ulnar nerve cortex. In the epilepsy patient, the source localizations obtained in scalp EEGs showed good agreement with those on ECoGs. We conclude that SEPs recorded in scalp EEGs can be used to study functional topography of human somatosensory cortex non-invasively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏