首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A sensitive assay for adenovirus quantitation in vitro was developed using the flow microsphere immunoassay (FMIA) approach. Polystyrene microspheres were covalently coated with purified anti-adenoviral antibodies and incubated with virus-containing samples. After incubation, the samples were stained with DNA-specific fluorescent dyes, and microsphere-associated fluorescence was quantitated with a flow cytometer. The adsorption of virus to microspheres was examined under different experimental conditions. The flow cytometric assay was determined to be as accurate in detecting adenovirus as titering on 293 cells. The proposed method can be used to quantify virus in viral stocks and in biological samples.  相似文献   

2.
This paper demonstrates a new magnetophoretic position detection method for multiplexed immunoassay using colored microspheres as an encoding tool in a microchannel. Colored microspheres conjugated with respective capture molecules are incubated with a mixture of target analytes, followed by reaction with the probe molecules which had been conjugated with superparamagnetic nanoparticles (SMNPs). Under the magnetic field gradient, the resulting microspheres are deflected from their focused streamlines in a microchannel, and respective colored microspheres are detected using color charge-coupled device (CCD) in a specific detection region of the microchannel. The color and position of respective colored microspheres are automatically decoded and analyzed by MATLAB program, and the position was correlated with the concentration of corresponding target analytes. As a proof-of-concept, we attempted to assay simultaneously three types of biotinylated immunoglobuline Gs (IgGs), such as goat, rabbit and mouse IgGs, using colored microspheres (red, yellow and blue, respectively). As the capture molecules, corresponding anti-IgGs were employed and target analytes were probed using streptavidin-modified superparamagnetic nanoparticles. As a result, three analytes were simultaneously assayed using colored microspheres with high accuracy, and detection limits of goat IgG, rabbit IgG and mouse IgG were estimated to be 10.9, 30.6 and 12.1fM, respectively. In addition, with adjustment of the flow rate and detection zone, the dynamic range could be controlled by more than one order of magnitude.  相似文献   

3.
We have developed a simple, homogeneous bead-based immunoassay for use with fluorometric microvolume assay technology (FMAT). The FLISA (fluorescence-linked immunosorbent assay) can be easily adapted from existing immunoassays, is comparable to traditional ELISAs with respect to linear dynamic range and sensitivity, and can be readily performed in 96- and 384-well plates. Additionally, the FLISA utilizes 100-fold less primary antibody than the conventional immunoassay. The scanner uses a helium/neon laser to image and measure bead-bound fluorescence while the background fluorescence is ignored. Consequently, no wash steps are required to remove unbound antibody, ligand, and fluorophore. Furthermore, the instrument is capable of detecting two different fluorescent dyes, allowing for multiplexed assays based on color. Fluorescent bead-based immunoassays were developed for the cytokines IL-6 and IL-8, and their use in both one-color and two-color FLISAs is demonstrated. Although no wash steps were employed, the FLISA was able to accurately measure the concentrations of IL-6 and IL-8 in the growth media of cytokine-stimulated HUVEC cells. In addition, a simulated high-throughput two-color FLISA positively identified those wells in a 384-well plate that contained different amounts of IL-6 and/or IL-8 peptide. The homogeneous, multiplex and multiplate format of the FLISA reduces hands-on time and reagent usage, and is therefore ideally suited for high-throughput screening.  相似文献   

4.
New developments in detection technologies are providing a variety of biomolecular screening strategies from which to choose. Consequently, we performed a detailed analysis of both separation-based and non-separation-based formats for screening nuclear receptor ligands. In this study, time-resolved fluorescence resonance energy transfer (TR-FRET), ALPHAScreen, and time-resolved fluorescence (TRF) assays were optimized and compared with respect to sensitivity, reproducibility, and miniaturization capability. The results showed that the ALPHAScreen system had the best sensitivity and dynamic range. The TRF assay was more time consuming because of the number of wash steps necessary. The TR-FRET assay had less interwell variation, most likely because of ratiometric measurement. Both the ALPHAScreen and the TR-FRET assays were miniaturized to 8-microl volumes. Of the photomultiplier tube-based readers, the ALPHAScreen reader (ALPHAQuest) presented the advantage of faster reading times through simultaneous reading with four photomultiplier tubes.  相似文献   

5.
We succeeded in using 40 nm FRET (fluorescence resonance energy transfer) microspheres conjugated to antibodies as the fluorescent reporters to perform the multiplexing suspension array measurements on two simulants of biological threats, ricin (A chain) and a crude spore preparation of Bacillus globigii (Bg). The microspheres were impregnated with two types of fluorophores in equal number (approximately 140 fluorophores in total per microsphere) and displayed bright PE-like fluorescence via a fluorescence resonance energy transfer mechanism. Activated microspheres (aldehyde groups) were directly coupled to antibodies and used to form sandwich-type immunoassays in a suspension array. For the crude preparations of Bg, the assay sensitivity using antibody-conjugated microspheres is an order of magnitude higher than that using the conventional fluorescent reporter, R-phycoerythrin (PE). Using the microspheres, Bg at the concentration of 5 ng/mL can be easily detected. For ricin, the assay sensitivity was similar to that obtained using PE as the reporter, but washing the reaction mixtures resulted in the fluorescence signals that were 2-3 times higher compared to those using PE. Ricin at a concentration of 1 ng/mL can be readily identified. Importantly, the two simulants do not interfere with each other in the multiplexing experiments. The 40 nm FRET microspheres are a new sensitive alternative as fluorescent reporters for detection in suspension arrays.  相似文献   

6.
BACKGROUND: We have developed a rapid, high throughput method for single nucleotide polymorphism (SNP) genotyping that employs an oligonucleotide ligation assay (OLA) and flow cytometric analysis of fluorescent microspheres. METHODS: A fluoresceinated oligonucleotide reporter sequence is added to a "capture" probe by OLA. Capture probes are designed to hybridize both to genomic "targets" amplified by polymerase chain reaction and to a separate complementary DNA sequence that has been coupled to a microsphere. These sequences on the capture probes are called "ZipCodes". The OLA-modified capture probes are hybridized to ZipCode complement-coupled microspheres. The use of microspheres with different ratios of red and orange fluorescence makes a multiplexed format possible where many SNPs may be analyzed in a single tube. Flow cytometric analysis of the microspheres simultaneously identifies both the microsphere type and the fluorescent green signal associated with the SNP genotype. RESULTS: Application of this methodology is demonstrated by the multiplexed genotyping of seven CEPH DNA samples for nine SNP markers located near the ApoE locus on chromosome 19. The microsphere-based SNP analysis agreed with genotyping by sequencing in all cases. CONCLUSIONS: Multiplexed SNP genotyping by OLA with flow cytometric analysis of fluorescent microspheres is an accurate and rapid method for the analysis of SNPs.  相似文献   

7.
Herein, we describe a protocol for simultaneously measuring six proteins in saliva using a fiber-optic microsphere-based antibody array. The immuno-array technology employed combines the advantages of microsphere-based suspension array fabrication with the use of fluorescence microscopy. As described in the video protocol, commercially available 4.5 μm polymer microspheres were encoded into seven different types, differentiated by the concentration of two fluorescent dyes physically trapped inside the microspheres. The encoded microspheres containing surface carboxyl groups were modified with monoclonal capture antibodies through EDC/NHS coupling chemistry. To assemble the protein microarray, the different types of encoded and functionalized microspheres were mixed and randomly deposited in 4.5 μm microwells, which were chemically etched at the proximal end of a fiber-optic bundle. The fiber-optic bundle was used as both a carrier and for imaging the microspheres. Once assembled, the microarray was used to capture proteins in the saliva supernatant collected from the clinic. The detection was based on a sandwich immunoassay using a mixture of biotinylated detection antibodies for different analytes with a streptavidin-conjugated fluorescent probe, R-phycoerythrin. The microarray was imaged by fluorescence microscopy in three different channels, two for microsphere registration and one for the assay signal. The fluorescence micrographs were then decoded and analyzed using a homemade algorithm in MATLAB.  相似文献   

8.
A duplexed microsphere-based fluorescent immunoassay   总被引:1,自引:0,他引:1  
Microsphere-based immunoassays are described for the simultaneous measurement of the clinically important drugs digoxin and theophylline. Competitive immunoassays were performed using haptenized microspheres and antibodies labeled with horseradish peroxidase. Enzyme-catalyzed reporter deposition (CARD) resulted in immunofluorescence signal amplification. Two encoding dyes were used to differentiate analytical signals from microspheres containing assays for the two analytes. An epifluorescence microscope and a CCD camera interfaced with a computer were utilized to measure fluorescence signals of individual microspheres. The microspheres from a duplexed assay were mounted on microscope slides as well as inserted into wells etched into the distal ends of optical imaging fibers. Fluorescence images from both formats were captured. In the experiments using microscope slides, the immunoassays were successfully duplexed and only marginal interferences at high analyte concentrations were observed. Preliminary results suggest that simultaneous determination of the two analytes using a fiber-based sensor-array format is feasible, but requires further development before precise quantitative analyses are possible.  相似文献   

9.
We report here an extension of homogeneous assays based on fluorescence intensity and lifetime measuring on DNA hybridization. A novel decay probe that allows simple one-step nucleic acid detection with subnanomolar sensitivity, and is suitable for closed-tube applications, is introduced. The decay probe uses fluorescence resonance energy transfer (FRET) between a europium chelate donor and an organic fluorophore acceptor. The substantial change in the acceptor emission decay time on hybridization with the target sequence allows the direct separation of the hybridized and unhybridized probe populations in a time-resolved measurement. No additional sample manipulation or self-hybridization of the probes is required. The wavelength and decay time of a decay probe can be adjusted according to the selection of probe length and acceptor fluorophore, thereby making the probes applicable to multiplexed assays. Here we demonstrate the decay probe principle and decay probe-based, one-step, dual DNA assay using celiac disease-related target oligonucleotides (single-nucleotide polymorphisms [SNPs]) as model analytes. Decay probes showed specific response for their complementary DNA target and allowed good signal deconvolution based on simultaneous optical and temporal filtering. This technique potentially could be used to further increase the number of simultaneously detected DNA targets in a simple one-step homogeneous assay.  相似文献   

10.
We have developed a simple and sensitive fluorescence-based two-step coupled enzyme assay to report the activity of S-adenosylmethionine-dependent methyltransferases. This assay relies on a fluorescein-cystamine-methyl red (FL-S-S-MR) reporter molecule that can be activated by thiols. In the absence of thiols, fluorescence from the reporter is quenched through fluorescence resonance energy transfer between the two chromophores. In this report, we use catechol-O-methyltransferase with the addition of S-adenosylhomocysteine hydrolase to produce the thiol homocysteine. The presence of homocysteine leads to disulfide bond cleavage in the cystamine tether and fluorescence dequenching as the uncoupled chromophores are diluted into the surrounding media. The sensitivity and specificity of FL-S-S-MR to thiols enabled detection of 相似文献   

11.
A novel fluorescent microbead immunoassay (FMIA) using the recombinant polypeptide SpaA415 was developed for detection of anti-Erysipelothrix spp. IgG in pig sera. The diagnostic performance of the FMIA was evaluated on samples from pigs with known and unknown Erysipelothrix spp. exposure and compared to an in-house enzyme-linked immunosorbent assay (ELISA-1) based on the same capture antigen, and two commercially available ELISAs (ELISA-2 and ELISA-3). Sera from pigs experimentally infected with Erysipelothrix rhusiopathiae serotype 1a (n=60) or 19 (n=12), sera from pigs vaccinated with a commercial attenuated-live vaccine based on serotype 1a (n=12) or a commercial bacterin based on serotype 2 (n=12), and 90 field samples were utilized. The sensitivity on 22 true positive samples collected in the later stages of infection/post-vaccination was 100% for the FMIA and ELISA-1, 63.6% for ELISA-2 and 81.8% for ELISA-3. The earliest antibody response was detected 7days post inoculation with the FMIA (77.8%) and ELISA-1 (11.1%), and at 14days post-vaccination (dpv) with FMIA (50%) and ELISA-1 (50%). On field samples, a higher seroprevalence was found in pigs older than 21days with all four assays. Kappa analysis indicated that the FMIA and ELISA-1 had almost complete agreement whereas the agreement was slight with ELISA-2 and fair with ELISA-3. The sensitivity of both immunoassays based on the rSpaA415 antigen was higher compared to that of the two commercial ELISAs. The rSpaA415 FMIA has great potential as an inexpensive ELISA alternative for detection of antibodies against E. rhusiopathiae in the future.  相似文献   

12.
Phospholipid molecules such as ceramide and phosphoinositides play crucial roles in signal transduction pathways. Lipid-modifying enzymes including sphingomyelinase and phosphoinositide kinases regulate the generation and degradation of these lipid-signaling molecules and are important therapeutic targets in drug discovery. We now report a sensitive and convenient method to separate these lipids using microfluidic chip-based technology. The method takes advantage of the high-separation power of the microchips that separate lipids based on micellar electrokinetic capillary chromatography (MEKC) and the high sensitivity of fluorescence detection. We further exploited the method to develop a homogenous assay to monitor activities of lipid-modifying enzymes. The assay format consists of two steps: an on-plate enzymatic reaction using fluorescently labeled substrates followed by an on-chip MEKC separation of the reaction products from the substrates. The utility of the assay format for high-throughput screening (HTS) is demonstrated using phospholipase A(2) on the Caliper 250 HTS system: throughput of 80min per 384-well plate can be achieved with unattended running time of 5.4h. This enabling technology for assaying lipid-modifying enzymes is ideal for HTS because it avoids the use of radioactive substrates and complicated separation/washing steps and detects both substrate and product simultaneously.  相似文献   

13.
In this study we describe a novel method of sampling and quantifying wound biomarkers for clinical settings. We believe the chosen format will allow rapid assessments of wound healing and provide biomarker evidence-based decision points for treatment of the wound at the time of presentation. The wound monitoring principle uses a proprietary sample collection tool (a thermally reversible hydrogel) to sample and isolate biomarkers within a wound environment without further sample extraction/preparation steps. We show how gel samples can be analysed in a lateral flow assay format utilising fluorescent microspheres with optically discrete emission characteristics and demonstrate quantitative detection of two analytes (duplexing) achieved in a single test line. As a model assay, the chronic wound biomarkers interleukin 6 (IL6) and tumour necrosis factor alpha (TNFα) are used. Limits of detection of 48.5 pg/mL and 55.5 pg/mL respectively in hydrogel samples and 7.15 pg/mL and 10.7 pg/mL respectively in plasma are reported. We believe this is the first literature example of quantitative detection of multiple analytes within a single test line using spectral separation to distinguish the analytes.  相似文献   

14.
We describe the use of fluorophore-doped nanoparticles as reporters in a recently developed ArcDia TPX bioaffinity assay technique. The ArcDia TPX technique is based on the use of polymer microspheres as solid-phase reaction carrier, fluorescent bioaffinity reagents, and detection of two-photon excited fluorescence. This new assay technique enables multiplexed, separation-free bioaffinity assays from microvolumes with high sensitivity. As a model analyte we chose C-reactive protein (CRP). The assay of CRP was optimized for assessment of CRP baseline levels using a nanoparticulate fluorescent reporter, 75 nm in diameter, and the assay performance was compared to that of CRP assay based on a molecular reporter of the same fluorophore core. The results show that using fluorescent nanoparticles as the reporter provides two orders of magnitude better sensitivity (87 fM) than using the molecular label, while no difference between precision profiles of the different assay types was found. The new assay method was applied for assessment of baseline levels of CRP in sera of apparently healthy individuals.  相似文献   

15.
Capillary electrophoresis-based immunoassay (CEIA) is a developing analytical technique with a number of advantages over conventional immunoassay, such as reduced sample consumption, simpler procedure, easy simultaneous determination of multiple analytes, and short analysis time. However, there are still a number of technical issues that researchers on CEIA have to solve before the assay can be more widely used. These issues include method to improve the concentration sensitivity of the assay, requirement for robust separation strategy for different analytes, and method to increase the throughput of the assay. The approaches to solve these issues are reviewed. Several studies have been devoted to develop general separation strategies for CEIA, and to enhance the sensitivity of detection. The recent development of microchip-based CEIA is encouraging and is likely to address more drawbacks of CEIA, particularly on the throughput issue.  相似文献   

16.
Simplifying microarray workflow is a necessary first step for creating MDR-TB microarray-based diagnostics that can be routinely used in lower-resource environments. An amplification microarray combines asymmetric PCR amplification, target size selection, target labeling, and microarray hybridization within a single solution and into a single microfluidic chamber. A batch processing method is demonstrated with a 9-plex asymmetric master mix and low-density gel element microarray for genotyping multi-drug resistant Mycobacterium tuberculosis (MDR-TB). The protocol described here can be completed in 6 hr and provide correct genotyping with at least 1,000 cell equivalents of genomic DNA. Incorporating on-chip wash steps is feasible, which will result in an entirely closed amplicon method and system. The extent of multiplexing with an amplification microarray is ultimately constrained by the number of primer pairs that can be combined into a single master mix and still achieve desired sensitivity and specificity performance metrics, rather than the number of probes that are immobilized on the array. Likewise, the total analysis time can be shortened or lengthened depending on the specific intended use, research question, and desired limits of detection. Nevertheless, the general approach significantly streamlines microarray workflow for the end user by reducing the number of manually intensive and time-consuming processing steps, and provides a simplified biochemical and microfluidic path for translating microarray-based diagnostics into routine clinical practice.  相似文献   

17.
BACKGROUND: Spectral interference (overlap) from phagocytosed green-yellow (GY) microspheres in the flow cytometric, red fluorescence emission measurement channel causes errors in quantifying damaged/dead alveolar macrophages by uptake of propidium iodide. METHODS: Particle burdens of uniform GY fluorescent microspheres phagocytosed by rat alveolar macrophages and the discrimination of damaged/dead cells as indexed by propidium iodide uptake were assessed with conventional and phase-sensitive flow cytometry. RESULTS: The fluorescence spectral emission from phagocytosed microspheres partly overlapped the propidium iodide red fluorescence emission and interfered with the measurement of damaged/dead cells when using conventional flow cytometry without subtractive compensation. This caused errors when estimating the percentage of nonviable, propidium iodide-positive, phagocytic macrophages. The interference was eliminated by employing phase-sensitive detection in the red fluorescence measurement channel based on differences in fluorescence lifetimes between the fluorescent microspheres and propidium iodide. Intrinsic cellular autofluorescence, whose fluorescence lifetime is approximately the same as that of the phagocytosed microspheres, also was eliminated in the phase-sensitive detection process. Because there was no detectable spectral interference of propidium iodide in the green fluorescence (phagocytosis) measurement channel, conventional fluorescence detection was employed. CONCLUSIONS: Phase-resolved, red fluorescence emission measurement eliminates spectral overlap errors caused by autofluorescent phagocytes that contain fluorescent microspheres in the analyses of propidium iodide uptake.Cytometry 39:45-55, 2000. Published 2000 Wiley-Liss, Inc.  相似文献   

18.
Huan B  Van Atta R  Cheng P  Wood ML  Zychlinsky E  Albagli D 《BioTechniques》2000,28(2):254-5, 258-60
In situ hybridization techniques have been an important research tool since first introduced 30 years ago, and more recently clinical applications have been expanding greatly. Still, further improvements in the assay sensitivity and protocols that are amenable to routine clinical use are desired. We use a novel photo-cross-linking technology to irreversibly bind short oligonucleotide probes to the target sequence following a hybridization period. The cross-linking agent is incorporated into the backbone of the probe and is activated to react with pyrimidines in the opposite strand by near-UV (300-370 nm) irradiation. By locking the probe to the target, very stringent wash conditions can be used that would otherwise completely remove probes that are hybridized but not cross-linked to the target. Consequently, the probe-specific signal is maximized, while the background signal is minimized to the greatest extent possible with the stringency of the wash. The use of short, photo-cross-linkable probes presents a new strategy for maximizing the sensitivity of probe hybridization or signal amplification-based in situ techniques.  相似文献   

19.
We describe two fluorescence immunoassays capable of detecting endocrine disrupting compounds in waste water. The first fluorescence method is a heterogeneous assay using total internal reflection fluorescence (TIRF) detection. The second method is a homogeneous assay that utilizes energy transfer (ETIA). Both fluorescence immunoassays are compared with respect to detection principle and ability to quantify the model analytes estrone, estradiol, and ethinylestradiol in a complex matrix regarding recovery rates and limits of detection. Calibrations were performed for the three analytes using both fluorescence methods. Limits of detection between 0.01 and 0.85 microg/l are achieved. In addition, measurements in synthetic waste water spiked with the analytes were performed. Both immunoassays allow the detection in waste water with recovery rates in the range of 70-112%.  相似文献   

20.
This report describes a new flow cytometry technique to measure phagocytic activity and discriminate simultaneously between internalized and membrane-bound particles. Fluorescein-conjugated heat-killed Candida albicans (F-Ca) are opsonized with purified antibodies or normal human serum and used as targets for human polymorphonuclear granulocytes (PMN). The procedure is based on the observation that F-Ca lose their green fluorescence and acquire red fluorescence upon incubation with ethidium bromide (EB) through the resonance energy-transfer phenomenon occurring between the two fluorochromes. PMN are incubated with opsonized F-Ca particles for 20 min at 37 degrees C or, as a control, at 4 degrees C and in the presence of cytochalasin B, an inhibitor of the phagocytic process that does not affect membrane binding of F-Ca. EB is added, and green and red fluorescence associated with PMN is evaluated using a mercury-lamp-powered instrument. Because EB does not penetrate intact cell membranes, internalized particles are not affected by EB and remain green, whereas membrane-bound particles assume an intense red stain. By means of contour plot analysis, the number of PMN containing and/or binding F-Ca particles can be readily assessed. The method described here allows precise quantitative analysis of the phagocytic process on the part of human PMN in a single, one-step assay that does not require sophisticated instrumentation or reagents and should prove to become a test suitable for clinical purposes.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号