首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A newly devised, very accurate (“definitive”) method for the determination of trace amounts of cobalt in biological materials was validated by the analysis of several certified reference materials. The method is based on a combination of neutron activation and selective and quantitative postirradiation isolation of radiocobalt from practically all other radionuclides by ion-exchange and extraction chromatography followed by γ-ray spectrometric measurement. The significance of criteria that should be fulfilled in order to accept a given result as obtained by the “definitive method” is emphasized. In view of the demonstrated very good accuracy of the method, it is suggested that our values for cobalt content in those reference materials in which it was originally not certified (SRM 1570 spinach, SRM 1571 orchard leaves, SRM 1577 bovine liver, and Czechoslovak bovine liver 12-02-01) might be used as provisional certified values.  相似文献   

2.
An outline of the processes involved in both certified clinical reference material production and clinical reference measurement procedure development at the National Institute of Standards and Technology (NIST), the national metrology institute of the United States, is presented. The role that NIST and other national metrology institutes play in the metrological traceability of certified reference material is discussed. Highlighted are the challenges associated with the development of reference measurement systems for complex clinical analytes, such as proteins, and examples of existing efforts in this area are given. Examples of recent international collaborations in developing certified reference materials for analytes such as cardiac troponin I, brain natriuretic peptide, and serum creatinine demonstrate the close cooperation that national metrology institutes must have with the clinical community to establish complete reference measurement systems.  相似文献   

3.
In order to help resolve present inconsistencies of two orders of magnitude or more in reported levels of vanadium in human serum and blood, a totally postirradiation radiochemical neutron activation analysis (NAA) method was further developed and applied to some pertinent nanogram and subnanogram reference materials. In particular, the second generation human serum reference material of Versieck was found to contain a value of 0.67±0.05 ng/g dry wt., corresponding to 0.061±0.005/4/ (see Table 1) ng/mL original fresh serum. Results are also reported for some other appropriate CRMs. Additionally, a small-scale study in 10 normal subjects (5 m, 5 f) revealed levels similar to those in the serum reference material and in agreement with the lowest data reported in the literature. Discussion of pitfalls of vanadium determination and the use of reference materials is included.  相似文献   

4.
Uric acid is an important diagnostic marker of catabolism of the purine nucleosides, and accurate measurements of serum uric acid are necessary for proper diagnosis of gout or renal disease appearance. A candidate reference method involving isotope dilution coupled with liquid chromatography/mass spectrometry (LC/MS) has been described. An isotopically labeled internal standard, [1,3-(15)N(2)] uric acid, was added to serum, followed by equilibration and protein removal clean up to prepare samples for liquid chromatography/mass spectrometry electrospray ionization (LC/MS-ESI) analyses. (M-H)(-) ions at m/z 167 and 169 for uric acid and its labeled internal standard were monitored for LC/MS. The accuracy of the measurement was evaluated by a comparison of results of this candidate reference method on lyophilized human serum reference materials for uric acid (Standard Reference Materials SRM909b) with the certified values determined by gas chromatography/mass spectrometry reference methods and by a recovery study for the added uric acid. The method performed well against the established reference method of ion-exchange followed by derivatization isotope dilution (ID) gas chromatography mass spectrometry (ID-GC/MS). The results of this method for uric acid agreed well with the certified values and were within 0.10%. The amounts of uric acid recovered and added were in good agreement for the three concentrations. This method was applied to determine uric acid in samples of frozen serum pools. Excellent precision was obtained with within-set CVs of 0.08-0.18% and between-set CVs of 0.02-0.07% for LC/MS analyses. Liquid chromatography/tandem mass spectrometry electrospray ionization (LC/MS/MS-ESI) analysis was also performed. The LC/MS and LC/MS/MS results were in very good agreement (within 0.14%). This LC/MS method, which demonstrates good accuracy and precision, and is in the speed of analysis without the need for a derivatization stage, qualifies as a candidate reference method. This method can be used as an alternative reference method to provide an accuracy base to which the routine methods can be compared.  相似文献   

5.
A continuing fundamental trend in the area of quality assurance in analytical laboratories are measures that enable trace-ability of analytical results to internationally renowned units, like e.g. the mole. Especially certified reference materials (CRMs) are important tools for achieving this goal. What are CRMs? Why do we need them in the field of mycotoxin analysis? Which kind of CRMs are currently available for the determination of mycotoxins and how should they be used? These are questions, which are increasingly being asked. This article attempts to answer these questions.  相似文献   

6.
Quan C  Su F  Wang H  Li H 《Steroids》2011,76(14):1527-1534

Background

The need for certified reference materials (CRM) of anabolic-androgenic steroids reference materials was emphasized by the Beijing 2008 Olympic game as a tool to improve comparability, ensuring accuracy and traceability of analytical results for competing athletes. The China National Institute of Metrology (NIM) responded to the state request by providing seven anabolic-androgenic steroids (AAS) reference materials for Beijing Olympic anti-doping, GBW (E) 100086-GBW (E) 100092.

Experimental

This work describes the production of the series of AAS CRMs, according to ISO Guides 34 and 35 [1] and [2], which comprises the material processing, homogeneity and stability assessment, CRMs’ characterization including moisture content, trace metal content. The AASs’ purity values were assigned with collaborative study involved eight laboratories applying high resolution liquid chromatography-diode array detector (HPLC-DAD). Homogeneity of the AAS CRMs were determined by an in-house validated liquid chromatographic methodology. Potential degradation during storage was also investigated and a shelf-life based on this value was established.

Results

The certified values of CRMs were 99.76 ± 0.079%, 99.76 ± 0.25%, 99.63 ± 0.09%, 99.67 ± 0.11%, 98.82 ± 0.56%, 96.30 ± 0.39% and 99.71 ± 0.49% (purity ± expanded uncertainty with confidence level of 95%) for methyltestosterone, testosterone propionate, nandrolone, nandrolone 17-propionate, boldenone, trenbolone acetate and testosterone respectively.

Conclusions

The certified values for all the studied AAS reference materials are traceable to the international system of units (SI). The CRMs developed were applied by 32 laboratory including sports organizations and analytical laboratories during the 2008 Olympic game for anti-doping control.  相似文献   

7.
Six arsenic compounds including arsenocholine, arsenobetaine, dimethylarsinic acid, methylarsonic acid, arsenous acid and arsenic acid were separated by high-performance liquid chromatography (HPLC) on a Hamilton PRP-X100 anion-exchange column using isocratic elution and detected by inductively coupled plasma mass spectrometry (ICP-MS). This analytical procedure was applied to the speciation of arsenic compounds in human urine. The influence of urine matrix on the separation of arsenic compounds was evaluated and the determination of arsenic compounds was not hampered by the ArCl interference which has often been encountered in ICP-MS. Three human urine reference materials, SRM 2670 normal level, SRM 2670 elevated level and Lyphocheck urine metal control 1, were analyzed with respect to arsenic compounds by HPLC-ICP-MS. The results were found to be in good agreement with the certified total arsenic concentration in the reference materials. Six arsenic compounds were detected. Arsenobetaine was found to be present in all of the investigated human urine reference materials.  相似文献   

8.
The incidence of rheumatoid arthritis (RA) has been associated with cigarette smoking. The aim of our study was to assess the trace essential and toxic metals, cadmium (Cd), lead (Pb), and zinc (Zn), in scalp hair samples of 32 Irish and 46 Pakistani smokers and non-smokers RA male patients with age range 42-56 years. For comparison purpose, the scalp hair samples of 27 Irish and 55 Pakistani non-RA male subjects of the same age group were collected. The concentrations of trace and toxic elements were measured by inductive coupled plasma atomic emission spectrophotometer and atomic absorption spectrophotometer prior to microwave-assisted acid digestion. The validity and accuracy of the methodology was checked using certified reference materials and using conventional wet acid digestion method on the same certified reference materials (CRMs). The recovery of all studied elements was found to be in the range of 97.5-99.7% of certified reference values of CRMs. The results of this study showed that the mean values of Cd and Pb were significantly higher in scalp hair samples of both smoker and non-smoker RA patients than in referents (P < 0.001), whereas the concentration of Zn was lower in the scalp hair samples of smokers and non-smokers rheumatoid arthritis patients. The deficiency of Zn and the high exposure of Cd and Pb as a result of cigarette smoking may be synergistic risk factors associated with rheumatoid arthritis.  相似文献   

9.
The first methods for the measurement of creatinine in serum and plasma were published over a century ago. Today, the Jaffe reaction using alkaline picrate remains the cornerstone of most current routine methods, after continuous refinements attempting to overcome inherent analytical interferences and limitations. With the recent introduction of the reporting of estimated glomerular filtration rate (eGFR), inter-laboratory agreement of serum creatinine results has become an important international priority. Expert professional bodies have recommended that all creatinine methods should become traceable to a reference method based on isotope dilution-mass spectrometry (IDMS).It is important that clinical biochemists have a good understanding of the relative performance of routine creatinine methods. Using a new commutable IDMS-traceable reference material (SRM 967), and a validated tandem IDMS assay developed in our laboratory, we assessed the accuracy of nine routine creatinine methods with assistance from other laboratories in our region. Three methods appeared to have patient sample bias that exceeded 5% in the range of creatinine concentrations where eGFR estimations are most important.Companies are currently recalibrating their creatinine assays. This task should be complete in 2007, and then creatinine results for eGFR calculations will require the use of a modified eGFR equation. Laboratories considering calibration changes before this time can seek advice from the Australasian Creatinine Working Group.  相似文献   

10.
A high-performance liquid chromatographic method for the determination of creatinine in control sera is reported, based on its separation from deproteinated serum components on the ion-exchange material HEMA Bio 1000 SB and ultraviolet detection at 230 nm. Groups of eleven to fourteen samples of human serum and several control materials were simultaneously analysed by the Jaffé, enzymic ultraviolet and enzymic peroxidase aminophenazone methods. Another group (52–115 sera) was analysed for correlations with spectrophotometric methods. The precision of the chromatographic method ranges between 2.0 and 1.0% (relative standard deviation) for serum creatinine concentrations of 115.1 to 471 μmol/l, respectively. A very good accuracy was found in analyses of reference materials Kontrollogen-L and -LP. Some results of analyses of the other control sera were higher and the other lower than those obtained by the Jaffé and enzymic methods, because both interferences and enzyme inhibitors were encountered. Correlations between the chromatographic and spectrophotometric methods were good.  相似文献   

11.
The pre-irradiation combustion (PC) of samples to liberate iodine, followed by trapping the iodine on charcoal and quantifying the element by neutron activation analysis (NAA), has been used at the National Institute of Standards and Technology for the determination of iodine in biological materials. The applicability of this technique to numerous environmental and dietary matrices is illustrated by analysis of a range of certified reference materials (CRMs) and a powdered grass material that was prepared as an in-house reference material (RM). Because of the combustion step involved, samples with low or no fat content (e.g., cereal products, selected botanical specimens, and nonfat milk powder) and inorganic materials (e.g., coal fly ash and dried sediments) are more suited for analysis by this method. In general, the results for several types of samples obtained by this method agreed with those obtained by a second radiochemical (R) NAA, as well as by a third method using inductively coupled plasma mass spectrometry (ICP-MS). PC-NAA is a useful technique for determining iodine in biological and environmental samples, especially for verification of iodine results obtained from other methods.  相似文献   

12.
In the present study, we developed a reference material (RM) using authentic hair samples for the determination of methamphetamine (MA) and its main metabolite, amphetamine (AP) in human hair. MA abusers' hair samples were collected, homogenized and finally bottled. The concentration of each bottle was determined using two extraction methods, agitation with 1% HCl in methanol at 38 degrees C and ultrasonication with methanol/5M HCl (20:1), followed by gas chromatography/mass spectrometry (GC-MS) after derivatization with trifluoroacetic anhydride (TFAA). Both analytical procedures were fully validated and their extraction efficiency was compared. The homogeneity of analytes was evaluated and their property values were determined with their uncertainties. The two methods were acceptable to analyze MA and AP in human hair through the validation and comparative studies using spiked and authentic hair samples as well as NIST SRM 2379 certified reference material. Satisfying homogeneity was reached for MA and AP in the prepared RM. Finally, a human hair RM containing MA and AP is prepared at the level of 7.64+/-1.24 and 0.54+/-0.07 ng/mg, respectively. This material can be useful in forensic laboratories for internal quality control and external quality assurance.  相似文献   

13.
In 1987, the International Programme on Chemical Safety (IPCS) in collaboration with the U.S. Environmental Protection Agency (U.S. EPA) and the U.S. National Institute of Standards and Technology (U.S. NIST) initiated an international collaborative study of the mutagenicity of complex environmental mixtures in the Ames Salmonella typhimurium mutation assay. The objectives of this study were: (1) to estimate the inter- and intra-laboratory variability associated with the extraction of mixtures for bioassay, (2) to estimate the inter- and intra-laboratory variability associated with the Salmonella typhimurium bioassay when applied to complex mixtures, and (3) to determine whether standard reference complex mixtures would be useful in mutagenicity studies and to evaluate whether reference or certified mutagenicity values determined from this collaborative study should be reported. The complex mixtures used in this study were selected from standard reference materials (SRMs) which had previously been issued by the U.S. NIST as SRM 1597 (coal tar), SRM 1649 (diesel particulate matter) and SRM 1650 (urban air particulate matter) with certified values for polycyclic aromatic hydrocarbons. These SRM complex mixtures are available to scientists as reference standards for analytical chemistry research and are under consideration as SRMs for mutagenicity studies of complex environmental mixtures. This paper briefly describes the final study design, protocol, selection of the complex mixtures, and implementation of this international study.  相似文献   

14.
The use of isotope dilution analysis (IDA) with inductively coupled plasma-mass spectrometry (ICP-MS) for the determination of oxidized metallothionein (MT) by a Cd-saturation method is investigated. The method developed here is a modification of an earlier methodology which used a radioactive Cd isotope ((109)Cd). While retaining the many advantages of this previous approach, the procedure presented here uses stable isotope ratio measurements ((114)Cd/(111)Cd) for the determination of MT. Experimental parameters governing the instrumental precision and accuracy for isotope ratio measurements of Cd by ICP-MS were characterized. Systematic errors, including mass bias, detector dead time, and spectroscopic interferences, could be easily corrected. The isotope dilution ICP-MS method was validated by the determination of very low levels of cadmium in biological certified reference materials (NIST SRM 2670 freeze-dried urine, IAEA H-8 horse kidney, and BCR TP-25 lichens). Finally, the IDA procedure was evaluated for the determination of oxidized MT by a Cd-saturation method previously developed using radioactive (109)Cd. The final procedure was applied to the quantification of MT in Long-Evans Cinnamon rat liver cytosol samples and the results were compared with data obtained for the same samples using the reference (109)Cd methodology. A good agreement between the analytical values obtained by both methods was observed.  相似文献   

15.
The aim of the present study was to compare the level of copper (Cu), iron (Fe) and zinc (Zn) in biological samples (serum, blood, urine, and scalp hair) of patients suffering from different viral hepatitis (A, B, C, D, and E; n?=?521) of both gender age ranged 31–45 years. For comparative study, 255 age-matched control subjects, of both genders residing in the same city were selected as referents. The elements in the biological samples were analyzed by flame atomic absorption spectrophotometry, prior to microwave-assisted acid digestion. The validity and accuracy of the methodology was checked by using certified reference materials (CRMs) and with those values obtained by conventional wet acid digestion method on same CRMs. The results of this study showed that the mean values of Cu and Fe were higher in blood, sera, and scalp hair samples of hepatitis patients, while Zn level was found to be lower than age-matched control subjects. The urinary levels of these elements were found to be higher in the hepatitis patients than in the age-matched healthy controls (p?<?0.05). These results are consistent with literature-reported data, confirming that the deficiency of zinc and hepatic iron and copper overload can directly cause lipid peroxidation and eventually hepatic damage.  相似文献   

16.
A stable isotope dilution gas chromatography-mass spectrometry method using enriched 65Cu as an internal standard is described for the determination of Cu in urine and serum. Chelating agents N,N'-ethylenebis-(trifluoroacetylacetoneimine) [H2(enTFA2)] and lithium bis(trifluoroethyl)dithiocarbamate [Li(FDEDTC)] were used and evaluated for memory effect. H2(enTFA2) did not show any appreciable memory effect, whereas Li(FDEDTC) was found to have a strong memory effect. Overall precision of 1.6% was obtained for determining Cu isotope ratios at a 10-ng level using H2(enTFA2). Cu concentrations in the National Institute of Standards and Technology (NIST) reference materials, freeze-dried urine SRM 2670, and human serum SRM 909 determined using the H2(enTFA2) chelating agent were in good agreement with the NIST-certified values. Isotope ratios determined by gas chromatography-mass spectrometry on samples with altered isotopic composition were in good agreement with the inductively coupled plasma-mass spectrometry data.  相似文献   

17.
There is accumulative evidence that the metabolism of iron and copper is altered in viral hepatic diseases, and these nutrients might have specific roles in their pathogenesis and progress. The aim of present study was to compare the level of copper (Cu) and iron (Fe) in biological samples (serum, urine, and scalp hair) of female patients suffering from different viral hepatitis (A, B, C, D, and E; n?=?253) of age range 31–45 years. For comparative study, 95 healthy females of the same age group residing in the same city were selected. The elements in the biological samples were analyzed by flame atomic absorption spectrophotometry, prior to microwave-assisted acid digestion. The validity and accuracy of the methodology was checked by using certified reference materials (CRMs) and with those values obtained by conventional wet acid digestion method on same CRMs. The results of this study showed that the mean values of Cu and Fe were higher in sera and scalp hair samples of hepatitis patients than age-matched control subjects, while the difference was significant (p?<?0.001), in the cases of viral hepatitis B and viral hepatitis C as compared to viral hepatitis A, D, and E. The urinary levels of these elements were found higher in the hepatitis patients than in the age-matched healthy controls (p?<?0.05). These results are consistent with literature-reported data, confirming that hepatic iron and copper overload can directly cause lipid peroxidation and eventually hepatic damage.  相似文献   

18.
The advantages and disadvantages of neutron activation analysis (NAA) and inductively coupled plasma-source mass spectrometry (ICP-MS) for the analysis of biological materials is reviewed. Comparison is made between NAA (instrumental) and ICP-MS (conventional pneumatic solution nebulization and laser ablation) analysis of the biological reference material National Bureau of Standards (NBS) SRM 1577 Bovine Liver. Relatively good agreement is achieved between the results for the 18 elements analyzed by both techniques and those either certified or reported in the literature. Elemental concentrations for Li, Mg, Al, Ca, Cr, Mn, Fe, Cu, Zn, Br, Rb, and Cs are also reported for IAEA Mixed Human Diet (H9), NBS SRM 909 Human Serum, and NBS SRM 1577a Bovine Liver, analyzed by solution nebulization ICP-MS.  相似文献   

19.
A method is described for the determination of mercury in human blood serum and packed blood cells employing neutron activation analysis. Great attention was devoted to the collection and manipulation of the samples. The accuracy and precision of the method were tested by analyzing biological reference materials and by comparing the concentrations measured in a number of serum samples to those obtained by another, independent technique (cold vapor atomic absorption spectrometry) in the same samples. The article reports the levels measured in blood serum and packed blood cells samples from 15 adult volunteers, as well as the figures determined in a “second-generation” biological reference material (freeze-dried human serum), prepared and conditioned at the University of Ghent.  相似文献   

20.
BackgroundA chloride test is an integral part of a basic metabolic panel that is essential for the assessment of a patient’s acid-base and electrolyte status. While many methods are available commercially for the routine measurement of chloride, there is a need to address the accuracy and variability among the measurement results, especially with the prevalence of patients seeking treatment across different healthcare providers for alternative opinions.MethodA method based on sector field inductively coupled plasma isotope dilution mass spectrometry (SF-ICP-IDMS) was developed for the measurement of chloride in human serum. The SF-ICP-IDMS method was then used to assign the target values in the Health Sciences Authority (HSA) External Quality Assessment (EQA) Programme to evaluate the results of chloride test from participating clinical laboratories.ResultsThe accuracy of the measurements was evaluated by comparing the results with the certified values of Electrolytes in Frozen Human Serum Certified Reference Materials (SRM 956c and SRM 956d) from the National Institute of Standards and Technology (NIST) at different chloride concentration levels. Over a five-year period from 2014–2018, the number of clinical laboratories which participated in the EQA Programme increased from 23 to 33. Comparison of robust means from the laboratories’ results with our assigned target values revealed a reduction in relative deviation over time. The relationship between the deviation of each brand of clinical analysers and the chloride levels was established, where a larger deviation was uncovered at low chloride concentration. The SF-ICP-IDMS method was further demonstrated to be comparable with methods used by other metrology institutes in an international comparison organised by HSA under the auspice of the Consultative Committee for Amount of Substance – Metrology in Chemistry and Biology (CCQM).ConclusionThe use of metrologically traceable assigned target values enabled the study of method biasness from a small pool of dataset in each of the four brands of clinical analysers in HSA EQA Programme. This work underscores the need to improve the accuracy of chloride measurements by regular participation in an accuracy-based EQA Programme.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号