首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
This paper presents the development of a simple liquid chromatography–tandem mass spectrometry (LC–MS/MS) method to determine corticosteroids in bovine urine sample matrices. This method uses a single phase extraction (SPE) for cleaning of the sample with an Oasis MAX cartridge at pH 9.0–9.5 and elution by a neutral organic solvent (acetonitrile/dichloromethane), followed by separation on a GEMINI C18 column in the gradient mode with acetate buffer (pH 4.1)/methanol. A triple quadrupole mass spectrometer equipped with a multimode ion source, set to negative atmospheric pressure chemical ionization (APCI) in the multiple reaction monitoring mode was used for detection. The main advantage of this method over other commonly used methods includes the use of SPE with a low volume cartridge for sample preparation and no ion suppression effects from matrix components of the urine samples in the LC–MS/MS analysis. This allowed a reduction the quantification limits (decision limits, CCα) for the first time to 0.1 μg/L (1 and 0.2 μg/L for triamcinolone and flumethasone, respectively). The developed method was validated in accordance with the European Union Commission Decision 2002/657 EC. The recoveries and within-laboratory reproducibility varied from 77% to 115% and 87% to 107.5%, respectively, at 2, 3, and 4 μg/L levels of corticosteroids. The relative standard deviation (RSD) of the measurements was lower than 30%. The decision limit was calculated by multiplying the signal-to-noise ratio by 3 and the obtained values were in the range of 0.1–1.0 μg/L, confirmed by the analysis of twenty blank samples, which were spiked at the desired concentrations. The detection capability was calculated by the addition of the decision limit and the standard deviation followed by multiplication by 1.64 of the within-laboratory reproducibility at 2 μg/L of corticosteroids. The method was applied to four urine samples, giving concentrations of prednisolone (PRED) residues in the range from 0.3 to 0.9 μg/L.  相似文献   

2.
A chemiluminescence-based biochip array sensing technique has been developed and applied to the screening of honey samples for residues of banned nitrofuran antibiotics. Using a multiplex approach, metabolites of the four main nitrofuran antibiotics could be simultaneously detected. Individual antibodies specific towards the metabolites were spotted onto biochips. A competitive assay format, with chemiluminescent response, was employed. The method was validated in accordance with EU legislation (2002/657/EC, 2002), and assessed by comparison with UHPLC-MS/MS testing of 134 honey samples of worldwide origin. A similar extraction method, based on extraction of the analytes on Oasis? SPE cartridges, followed by derivatisation with nitrobenzaldehyde and partition into ethyl acetate, was used for both screening and LC-MS/MS methods. The biochip array method was capable of detecting all four metabolites below the reference point for action of 1 μg kg(-1). The detection capability was below 0.5 μg kg(-1) for the metabolites AHD, AOZ and AMOZ; it was below 0.9 μg kg(-1) for SEM. IC(50) values ranged from 0.14 μg kg(-1) (AMOZ) to 2.19 μg kg(-1) (SEM). This biosensor method possesses the potential to be a fit-for-purpose screening technique in the arena of food safety technology.  相似文献   

3.
A system for an automatic sample preparation procedure followed by on-line injection of the sample extract into a gas chromatography–mass spectrometry (GC–MS) system was developed for the simultaneous analysis of seven barbiturates in human urine. Sample clean-up was performed by a solid-phase extraction (SPE) on a C18 disposable cartridge. A SPE cartridge was preconditioned with methanol and 0.1 M phosphate buffer. After loading a 1.5 ml volume of a urine sample into the SPE cartridge, the cartridge was washed with 2.5 ml of methanol–water (1:9, v/v). Barbiturates were eluted with 1.0 ml of chloroform–isopropanol (3:1, v/v) from the cartridge. The eluate (1 μl) was injected into a GC–MS system. The calibration curves, using an internal standard method, demonstrated a good linearity throughout the concentration range from 0.02 to 10 μg/ml for all barbiturates extracted. The proposed method was applied to several clinical cases. The total analysis time for 20 samples was approximately 14 h.  相似文献   

4.
A novel liquid chromatography-atmospheric-pressure chemical ionization-mass spectrometry (LC-APCI/MS) method was developed and validated for the simultaneous determination of four sesquiterpene pyridine alkaloids (wilfortrine, wilfordine, wilforgine and wilforine) in human plasma. The chromatographic separation was performed on a Shim-pack XR-ODS column using an ammonium acetate buffer solution-acetonitrile in a gradient program. The detection was achieved by an ion trap mass spectrometry in the positive selected ion monitoring (SIM) mode. The method utilized acetonitrile as protein precipitation solvent and followed by solid-phase extraction (SPE). Calibration curves were linear for the four alkaloids over the range of 0.5-100.0 μg/L with the limits of quantification of 0.5 μg/L, while the method exhibited the recovery of 86.5-98.6%, intra- and inter-day RSDs of less than 8.2% and 12.8%, respectively. Methodology was validated in line with the EU requirements (Commission Decision 2002/657/EC). Results of incurred samples demonstrated excellent reproducibility. To our knowledge, this is the first analytical method for simultaneous determination of the four sesquiterpene pyridine alkaloids in plasma. The method was applicable to clinical pharmaceutical research of alkaloids in rheumatoid arthritis volunteer patients after oral administrations.  相似文献   

5.
The residues of sulfonamides (SAs) in the foods of animal origin are of the major concern because they are harmful to the consumer's health and could induce pathogens to develop resistance. Rapid and efficient determination methods are urgently in need. A quantitative high performance liquid chromatography method (HPLC) and a confirmative liquid chromatography-tandem mass spectrometry (LC-MS/MS) for the simultaneous determination of 18 sulfonamides such as sulfamidinum, sulfanilamide, sulfisomidine, sulfadiazine, sulfapyridine, sulfathiazole, sulfamerazine, sulfadimidine, sulfamethoxypyridazine, sulfamethoxydiazine, sulfisoxazole, sulfachloropyridazine, sulfamethoxazole, sulfamonomethoxine, sulfadoxine, sulfaclozine, sulfadimethoxine, sulfaquinoxaline in the muscles, livers and kidneys of swine, bovine and chicken were developed and validated. The sample preparation procedures included a pressurized liquid extraction (PLE) with acetonitrile conducted at elevated temperature (70°C) and pressure (1400 psi). After clean-up with hydrophilic-lipophilic balance cartridge, the extraction solution was concentrated and analyzed by HPLC and LC-MS/MS analysis. 18 SAs were separated by the HPLC with a Zorbax SB-Aq-C18 column and the mobile phase of methanol/acetonitrile/1% acetic acid with a gradient system. The wavelength of UV for the HPLC detection was set at 285 nm. The LC-MS/MS analysis was achieved with a Hypersil Golden column and the mobile phase of acetonitrile and 0.1% formic acid aqueous solution with two gradient systems. The Limits of detection (LOD) and the limits of quantitation (LOQ) were 3 μg/kg and 10 μg/kg, respectively, for both of the HPLC and LC-MS/MS. Linearity was obtained with an average coefficient of determination (R) higher than 0.9980 over a dynamic range from the LOQ value up to 5000 μg/kg. The recoveries of the methods range from 71.1% to 118.3% with the relative standard derivation less than 13%. The peaks of interest with no interferences were observed throughout the chromatographic run. The sample pretreatment provided efficient extraction and cleanup that enables a sensitive and rugged determination of 18 SAs, the obtained results revealed that PLE, in comparison with other sample preparation methods applied, has significantly higher efficacy for SAs isolation from animal tissues.  相似文献   

6.
The use of nitrofurans as veterinary drugs in food-producing animals has been banned in the EU since the 1990s. Monitoring programs in the EU are based on the detection of protein-bound metabolites after slaughter. An UHPLC-MS/MS method was developed and validated for pre slaughter determination of four nitrofuran metabolites (AHD, AOZ, SEM, AMOZ) in animal plasma (bovine, ovine, equine and porcine). This method is proposed as an alternative method for on-farm surveillance. Plasma samples were derivatised with 2-nitrobenzaldehyde and subsequently extracted with organic solvent. Extracts were concentrated and then analysed by UHPLC-MS/MS. The method was validated according to Commission Decision 2002/657/EC. Inter-species recovery for AHD, AOZ, SEM and AMOZ was 72, 74, 57 and 71%, respectively. Decision limits (CCα) were calculated from within laboratory reproducibility experiments to be 0.070, 0.059, 0.071 and 0.054 μg kg(-1), respectively. In addition, the assay was applied to incurred plasma samples taken from pigs treated with furazolidone.  相似文献   

7.
A multi-residues method using pressurized liquid extraction (PLE) and liquid chromatography combined with mass spectrometry (LC-MS/MS) has been developed for determination of eight glucocorticoids (prednisone, prednisolone, hydrocortisone, methylprednisolone, dexamethasone, betamethasone, beclomethasone, fludrocortisone) in muscle of swine, cattle, and sheep. Parameters affecting PLE extraction including extraction solvent, extraction temperature, extraction pressure and extraction cycles were optimized. The optimized method employed 11 ml extraction cells, hexane-ethyl acetate (50:50, v/v) as extraction solvent, 1500 psi of extraction pressure and 50°C of extraction temperature. The samples were detected by LC-ESI-MS/MS in negative mode with selected reaction monitoring (SRM) mode. The recovery of glucocorticoids spiked at levels of 0.5-6 μg kg(-1) ranged from 70.1% to 103.1%; the between-day relative standard deviations were no more than 9.6%. The limits of quantification were 0.5-2 μg kg(-1) in muscle. The results demonstrated that the method is simple, fast, robust, and suitable for identification and quantification of glucocorticoids residues in foods of animal origin.  相似文献   

8.
A system of an automatic sample preparation procedure followed by on-line injection of the sample extract into a gas chromatograph-mass spectrometer (GC–MS) was developed for the simultaneous analysis of seven barbiturates in human serum. A sample clean-up was performed by a solid-phase extraction (SPE) on a C18 disposable cartridge. A SPE cartridge was preconditioned with methanol and 0.1 M phosphate buffer. After loading 1.5 ml of a diluted serum sample into the SPE cartridge, the cartridge was washed with 2.5 ml of methanol–water (1:9, v/v). Barbiturates were eluted with 1.0 ml of chloroform–isopropanol (3:1, v/v) from the cartridge. The eluate (1 μl) was injected into the GC–MS. The calibration curves, using an internal standard method, demonstrated a good linearity throughout the concentration range from 0.1 to 10 μg ml−1 for all barbiturates extracted. The proposed method was applied to 27 clinical serum samples from three patients who were administrated secobarbital.  相似文献   

9.
A specific and sensitive method based on liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been developed for the determination of nitrovin and sodium nifurstyrenate residues in muscle and liver of swine and chicken and in muscle of fish. Sample preparation procedure includes ultrasound-assisted extraction with acetonitrile, defatting with n-hexane and final clean-up with solid phase extraction (SPE) on Oasis HLB cartridges. The analytes were detected in multiple reaction monitoring (MRM) under negative scan mode acquiring two diagnostic product ions for sodium nifurstyrenate and under positive mode for nitrovin. The averaged decision limits (CCα; α 1%) ranged 0.09-0.26 μg/kg while the detection capability (CCβ; β 5%) was 0.33-0.97 μg/kg in the tissues. Reasonable recoveries (71-110%) spiked in muscle and liver showed excellent relative standard deviation (RSD). The validated method was simple, rapid, sensitive, and complied with the regulations for the determination of nitrovin and sodium nifurstyrenate residues in food matrices.  相似文献   

10.
A sensitive and selective method based on liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been developed for the quantitative determination of loperamide in human plasma. Automated solid-phase extraction (SPE) on disposable extraction cartridges (DEC) is used to isolate the compounds from the biological matrix and to prepare a cleaner sample before injection and analysis in the LC-MS/MS system. After conditioning, the plasma sample is loaded on the DEC filled with endcapped ethyl silica (C2(EC)) and washed twice with water. The analytes are therefore eluted by dispensing methanol. The eluate is then collected and added with ammonium acetate solution in order to inject an aliquot of this final extract in the LC-MS/MS system. On-line LC-MS/MS system using atmospheric pressure chemical ionization (APCI) has been developed for the determination of loperamide. The separation is obtained on a octadecylsilica based stationary phase using a mobile phase consisting in a mixture of methanol and 5mM ammonium acetate solution (25:75, v/v). Clonazepam is used as internal standard (IS). The MS/MS ion transitions monitored are m/z 477--> 266 and 316--> 270 for loperamide and clonazepam, respectively. The most appropriate regression model of the response function as well as the limit of quantitation were first selected during the pre-validation step. These latter criteria were then assessed during the formal validation step. The limit of quantitation (LOQ) was around 50 pg/ml for loperamide. The method was also validated with respect to recovery, precision, trueness, accuracy and linearity.  相似文献   

11.
In this paper, a new determination method for isometamidium residues in animal-derived foods was developed by liquid chromatography-tandem mass spectrometry (LC-MS/MS). Isometamidium residues in bovine tissues and milk were extracted with the mixed solution of acetonitrile and 0.25 mol/L of ammonium formate-methanol (v/v, 1:1), concentrated and degreased, and determined by LC-MS/MS with quantification by external standard method. The results showed that the peak area of chromatogram was linearly related to the concentration of isometamidium in the range of 1-100 μg/L, and the limits of detection (LOD) and quantification (LOQ) were 0.05 μg/kg and 5 μg/kg, respectively. The average recoveries of spiked samples were in the range of 73.8-93.9% with relative standard deviations ranged from 2.3% to 7.5%. This method is simple, accurate and suitable for the identification and quantification for isometamidium in animal-derived foods.  相似文献   

12.
A simple, quick and economical liquid chromatographic/tandem mass spectrometry (LC-MS/MS) method for the quantitative determination of amoxicillin in bovine muscle was developed and validated. The sample preparation procedure involved a liquid extraction with water, followed by a protein precipitation step with acetonitrile. The extract was purified by a liquid-liquid partition with dichloromethane and the upper aqueous layer was directly injected into the LC-MS/MS system. Chromatographic separation was achieved on a reversed phase column, using a mixture of acetonitrile, water and 0.005% formic acid in water as mobile phase. Gradient elution was performed at a flow rate of 0.2 mL min?1. Amoxicillin was detected using positive electrospray ionization in selected reaction monitoring (SRM) mode and was quantified using terbutaline as internal standard. The responses for standards prepared in solvent and in matrix were equivalent and additionally the absence of signal suppression was confirmed by the post column infusion technique. Amoxicillin stability in standard solution and in matrix was investigated at different times and storage conditions. Amoxicillin standards prepared in water were stable on storage up to 20 days at -20°C. Amoxicillin stability in matrix (spiked bovine muscle samples) was assessed up to 15 days at -20°C. The method was validated according to the parameters requested by European Commission Decision 2002/657/EC in terms of specificity, linearity, trueness, precision, decision limit (CCα) and detection capability (CCβ). All the trueness values fell within a range between 14.5% and 6.3%. Precision values for all levels of concentration tested were lower than the relative limit calculated by the Horwitz equation. The amoxicillin MRL is set at 50 μg kg?1 and the CCα and CCβ of the method were 61.2 μg kg?1 and 72.4 μg kg?1, respectively.  相似文献   

13.
Presently, the rise of new contaminants in the environment has widened the scope of pharmaceutical analyses as to face the demanding new challenges. An increasing tendency for the interconnection and overlap of research fields, such as ecology and biochemistry, is intensifying the demand for new methodologies to be applied to the survey of drugs in unconventional matrices. Integrated in this group are macrophytes, such as the green macroalgae Ulva lactuca, which are under study as to ascertain their ability as indicators of contamination for many substances. Nonetheless, methodologies for extraction and determination of drugs in such matrices are scarce and new studies on the subject are pressing. A new methodology for the determination of the antibiotic furaltadone in U. lactuca by liquid chromatography-tandem mass spectrometric (LC-MS/MS) procedure was developed, optimized and validated following the guidelines of the EC Decision 2002/657. The calibration curves showed linearity above 0.99 (R(2)). The relative standard deviations obtained for repeatability, expressed as CV, were between 15.3 and 20.5 and for reproducibility 25.3 and 28.2 whereas accuracy was in the interval of 88.9-95.5 (%). The limit of decision (CCα) and the detection capability (CCβ) were respectively 5.57 μg kg(-1) and 10.97 μg kg(-1). The method was successfully applied to experimental samples.  相似文献   

14.
A method was developed for the determination of several phenylurea and triazine herbicides and their transformation products in oysters at the low microg/kg level. Pressurised liquid extraction (PLE) of lyophilisated samples had required successive SPE combined with a liquid/liquid extraction to provide relatively clean extracts for the determination in LC-MS/MS. This procedure was validated according to the 2002/657/EC analytical decision. Efficiency of the analytical method led to confirmatory CCalpha values ranging from 0.1 to 14 microg/kg with an R.S.D. value ranging from 14% to 66% and a recovery yield ranging from 32% to 46% for phenylureas and from 29% to 75% for triazines.  相似文献   

15.
A highly sensitive and specific liquid chromatography/tandem mass spectrometric (LC-MS/MS) method for investigating the pharmacokinetics of adrafinil in rats was developed. Rat serum pretreated by solid-phase extraction (SPE) was analyzed by LC-MS/MS with an electrospray ionization (ESI) interface. The mobile phase consisted of acetonitrile:water:acetic acid (35:65:0.1, v/v/v) in an isocratic elution mode pumped at 1.0ml/min. The analytical column (250mmx4.6mm i.d.) was packed with Kromasil C(18) material (5.0mum). The standard curve was linear from 16.5 to 5000ng/ml. The assay was specific, accurate (R.S.D.<2.6%), precise and reproducible (within- and between-day precisions R.S.D. <7.0% and <9.0%, respectively). Adrafinil in rat serum was stable over three freeze-thaw cycles at ambient temperature for 6h. The method had a lower limit of quantitation of 16.5ng/ml, which offered high sensitivity for the determination of adrafinil in serum. The method was successfully applied to pharmacokinetic studies of adrafinil after an oral administration to rats.  相似文献   

16.
The Escherichia coli proteome was digested with trypsin and fractionated using SPE on a C18 SPE column. Seven fractions were collected and analyzed by CZE‐ESI‐MS/MS. The separation was performed in a 60‐cm‐long linear polyacrylamide‐coated capillary with a 0.1% v/v formic acid separation buffer. An electrokinetic sheath‐flow electrospray interface was used to couple the separation capillary with an Orbitrap‐Velos operating in higher‐energy collisional dissociation mode. Each CZE‐ESI‐MS/MS run lasted 50 min and total MS time was 350 min. A total of 23 706 peptide spectra matches, 4902 peptide IDs, and 871 protein group IDs were generated using MASCOT with false discovery rate less than 1% on the peptide level. The total mass spectrometer analysis time was less than 6 h, the sample identification rate (145 proteins/h) was more than two times higher than previous studies of the E. coli proteome, and the amount of sample consumed (<1 μg) was roughly fourfold less than previous studies. These results demonstrate that CZE is a useful tool for the bottom‐up analysis of prokaryote proteomes.  相似文献   

17.
The results of a validation study of a GC–NCI–MS method for the quantitative determination of 5-nitroimidazoles {1,2-Dimethyl-5-nitroimidazole (dimetridazole, DMZ), 1-methyl-2-[(carbamoyloxy)methyl]-5-nitroimidazole (ronidazole, RNZ), 1-(2-hydroxyethyl)-2-methyl-5-nitroimidazole (metronidazole, MNZ) and 2-isopropyl-1-methyl-5-nitroimidazole (ipronidazole, IPZ)} including the hydroxy metabolites of these agents {2-hydroxymethyl-1-methyl-5-nitroimidazole (HMMNI), 1-(2-hydroxyethyl)-2-hydroxymethyl-5-nitroimidazole (MNZOH), and 1-methyl-2-(2′-hydroxyisopropyl)-5-nitroimidazole (IPZOH)} in turkey and swine muscle are presented. The validation was carried out according to the requirements of the draft for the revision of Commission Decision 93/256/EC, which is expected to be adopted by the European Commission in due course. The determination of the method’s performance parameters revealed decision limits (CCα) between 0.65 and 2.8 μg/kg for DMZ, RNZ/HMMNI, MNZ and MNZOH. Confirmatory analyses according to the requirements of the forthcoming EC decision are possible for all analytes except for IPZ and IPZOH where already the decision limits (CCα) were higher (5.2 μg/kg) than for the above-mentioned nitroimidazoles. The within-laboratory reproducibility and the mean recovery were in an acceptable range for all analytes.  相似文献   

18.
A selective and sensitive, fully automated platform for verification and quantitative determination of target peptides in biofluids is proposed and then validated by development of a method for analysis of cathelicidin in human serum. The method is based on the on-line coupling of solid-phase extraction (SPE) and tandem mass spectrometry with direct infusion. Mass spectrometry analysis was carried out by multiple reaction monitoring using three transitions (one for quantitative analysis and two for qualitative analysis), all them confirmed by in silico fragmentation of the target peptide. Samples were prepared in the SPE workstation on a polymeric divinylbenzene resin by preconcentration, deproteinization, and cleanup, removing salts and interferences after direct injection of human serum. The analytical process required 12 min. The limits of detection and quantitation were 2.5 and 8.25 μg/L, respectively (0.20 and 0.66 pg on column). Repeatability and within-laboratory reproducibility were 2.4% and 2.7%, respectively. A dual-cartridge configuration was used to test recovery of cathelicidin in serum, resulting in 80%. Because quantitative retention in the cartridge was assessed, determination of cathelicidin was validated without using synthetic peptides labeled with stable isotopes. The hyphenated system allows full automation, thereby improving reproducibility and accuracy, as demanded by clinical analysis.  相似文献   

19.
To support pharmacokinetic studies, a selective and sensitive liquid chromatography/tandem mass spectrometry (LC-MS/MS) method has been developed and validated for the simultaneous determination of a novel KDR kinase inhibitor (1) and its active metabolite (2) in human plasma. The method is fully automated using a Packard MultiPROBE II system and a TomTec Quadra 96 liquid handling workstation to perform sample preparation and solid-phase extraction (SPE). Following the extraction on a mixed-mode SPE using Oasis MCX 96-well plate, the analytes were separated on a Aquasil C18 column (50 mm x 2.1 mm, i.d., 3 microm) with a mobile phase consisting of acetonitrile/ammonium acetate buffer (5 mM, pH 5.0) (60/40, v/v). The run time for each injection was 4.5 min with the retention times of approximately 2.0 and 2.7 min for 1 and 2 respectively, at a flow rate of 0.25 mL/min. A tandem mass spectrometric detection was conducted using multiple reaction monitoring (MRM) under the positive ion mode with a turbo ion-spray interface. The linear ranges of the calibration curves were 0.05-400 ng/mL for 1 and 0.1-400 ng/mL for 2 on a PE Sciex API 4000 LC-MS/MS system. The lower limits of quantitation (LLOQ) of the assay were 0.05 and 0.1 ng/mL for 1 and 2 respectively, when 0.4 mL of plasma was processed. Intra-day assay precision (using five standard curves prepared by spiking compounds to five lots of plasma) was less than 4.9% for 1 and less than 9.6% for 2 on each concentration. Assay accuracy was found to be 95.1-104.6% of nominal for 1 standards and 93.5-105.6% for 2 standards. QC samples were stable when kept at room temperature for 4 h, at -70 degrees C for 10 days, and after three freeze-thaw cycles. The extraction recoveries were 80%, 83% and 84% for 1 and 2 and I.S. respectively, and no significant matrix effects were observed. The method was successfully applied to plasma samples from clinical studies after oral administration of compound 1.  相似文献   

20.
Glycyrrhizin (GLY) which has been widely used in traditional Chinese medicinal preparation possesses various pharmacological effects. In order to investigate the pharmacokinetic behavior of GLY in human after oral administration of GLY or licorice root, a liquid chromatography/tandem mass spectrometry (LC-MS/MS) method was developed and validated for the simultaneous determination of GLY and its major metabolite glycyrrhetic acid (GA) in human plasma. The method involved a solid phase extraction of GLY, GA, and alpha-hederin, the internal standard (IS), from plasma with Waters Oasis MCX solid phase extraction (SPE) cartridges (30 mg) and a detection using a Micromass Quattro LC liquid chromatography/tandem mass spectrometry system with electrospray ionization source in positive ion mode. Separation of the analytes was achieved within 5min on a SepaxHP CN analytical column with a mobile phase of acetonitrile:water (50:50, v:v) containing 0.1% formic acid and 5mM ammonium acetate. Multiple reaction monitoring (MRM) was utilized for the detection monitoring 823--> 453 for GLY, 471--> 177 for GA and 752--> 456 for IS. The LC-MS/MS method was validated for specificity, sensitivity, accuracy, precision, and calibration function. The assay had a calibration range from 10 to 10,000 ng/mL and a lower limit of quantification of 10 ng/mL for both GLY and GA when 0.2 mL plasma was used for extraction. The percent coefficient of variation for accuracy and precision (inter-run and intra-run) for this method was less than 11.0% with a %Nominal ranging from 87.6 to 106.4% for GLY and 93.7 to 107.8% for GA. Stability of the analytes over sample processing (freeze/thaw, bench-top and long-term storage) and in the extracted samples was also tested and established.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号