首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
We evaluated stabilized whole blood control materials for their performance as a routine control material for immunophenotyping using flow cytometry. These materials serve as the method control, controlling for both the binding of monoclonal antibodies to the cells and the efficiency of the red-blood-cell lysing reagent. Three products (FluoroTrol, StatusFlow, and CD-Chex): were tested. The controls performed very well in evaluating both CD4 and CD8 percentages and absolute cell counts using flow cytometry. Light scattering patterns and fluorescence intensity of antibody binding were slightly different from those of normal whole blood. These products are not appropriate for quantitative fluorescence standards. Cytometry (Comm. Clin. Cytometry) 38:268-273, 1999. Published 1999 Wiley-Liss, Inc.  相似文献   

2.
A rapid immunochromatographic assay kit using whole blood to screen hepatitis B surface antigen was developed and evaluated by using sera from 240 patients. The reference diagnosis was based on the results obtained with GENEDIA Anti-HBs Rapid kit which is very similar to the above kit except for the use of serum. The test demonstrated a good correlation with the reference immunochromatographic assay kit, that is, the sensitivity and the specificity of the kit was 100%, respectively. The rapid test kit using whole blood should be more convenient and useful for the diagnosis of hepatitis B virus because the kit does not need machines and time to prepare serum. In addition, this kit is safe from inadvertent infection during sample treatment because the blood is sterilized with hydrogen peroxide, eliminates the procedure required to prepare serum and reduces the possibility of exposure to infectious agents.  相似文献   

3.
4.
5.
Single-cell gel electrophoresis (comet assay) is one of the most common methods used to measure oxidatively damaged DNA in peripheral blood mononuclear cells (PBMC), as a biomarker of oxidative stress in vivo. However, storage, extraction, and assay workup of blood samples are associated with a risk of artifactual formation of damage. Previous reports using this approach to study DNA damage in PBMC have, for the most part, required the isolation of PBMC before immediate analysis or freezing in cryopreservative. This is very time-consuming and a significant drain on human resources. Here, we report the successful storage of whole blood in ~ 250 μl volumes, at − 80 °C, without cryopreservative, for up to 1 month without artifactual formation of DNA damage. Furthermore, this blood is amenable for direct use in both the alkaline and the enzyme-modified comet assay, without the need for prior isolation of PBMC. In contrast, storage of larger volumes (e.g., 5 ml) of whole blood leads to an increase in damage with longer term storage even at − 80 °C, unless a cryopreservative is present. Our “small volume” approach may be suitable for archived blood samples, facilitating analysis of biobanks when prior isolation of PBMC has not been performed.  相似文献   

6.
7.
8.
Neurocysticercosis (NCC) is caused by the larval form of the pork tapeworm Taenia solium when lodged in the central nervous system (CNS). Clinical diagnosis of NCC is complicated due to its polymorphic manifestations with no specific signs or symptoms. A wide range of serological assays and neuroimaging modalities are used for its diagnosis. The aim of the present study was to evaluate the MTT assay for the diagnosis of NCC and to determine its sensitivity, specificity and accuracy. MTT assay was based upon the cellular reduction of the tetrazolium salt by the proliferating cells and quantification of the colored product. Total 59 patients with NCC-related active epilepsy (AE), 30 with AE other than NCC (disease controls) and 64 healthy volunteers were enrolled for the study. Lymphocytes were freshly isolated from the enrolled subjects and cultured on cyst fluid antigen coated tissue culture plates. MTT assay was performed according to the standard protocol. The mean values of proliferation index (PI) with cyst fluid antigens were 2.13 ± 0.72, 0.622 ± 0.31 and 0.71 ± 0.36 for NCC patients, disease controls and healthy volunteers respectively. PI values for NCC patients were higher than the cut-off value (mean of controls + 2 standard deviations; 1.31). The sensitivity, specificity and accuracy of the MTT assay for the diagnosis of NCC were 87.93%, 94.68% and 91.5% respectively. For single cyst infection the sensitivity of the assay was found to be 86.4%. The present study shows that MTT is an adaptable technique which can be used for diagnosis of NCC.  相似文献   

9.
A test-system based on enzyme-linked immunosorbent assay (ELISA) for quantitative determination of cyclosporin A (CSA) in human whole blood has been developed. The detection limit of the method was 25 ng/ml, the linearity of the method in the concentration range of 60–1400 ng/ml varied from 94 to 105%, the variation coefficient did not exceed 8%. The novel method exhibited good correlation with radioimmunoassay and polarization fluoroimmunoassay methods; the linear regression coefficients were 0.965 and 0.984, respectively. The developed test system is stable for at least 9 months when stored at 4°C and can be used in clinical practice.  相似文献   

10.
11.
12.
Growth of human lymphocyte colonies from whole blood following stimulation with PHA, Con A, or PPD is described. Individual colony cells were identified as T lymphocytes on the basis of surface marker and enzyme cytochemical characterizations. Colony formation increased as a power function over a wide range of cell concentrations above a critical minimal concentration. The whole blood culture system eliminates possible selective effects of lymphocyte colony techniques utilizing gradient-enriched lymphocyte fractions and more closely approximates the in vivo milieu. The whole blood colony method is more sensitive for the detection of low-level radiation effects on lymphocytes than widely used tests that measure 3H-thymidine incorporation. In preliminary studies, we used the whole blood method to determine the relative radiosensitivity of lymphocytes from humans with various hematopoietic disorders, and observed abnormalities in mitogen responsiveness and colony formation in some of the patient groups. This method has wide application for studies in cellular and clinical immunology.  相似文献   

13.
AIM: To evaluate US Centers for Disease Control and Prevention recommended swab surface sample collection method for recovery efficiency and limit of detection for powdered Bacillus spores from nonporous surfaces. METHODS AND RESULTS: Stainless steel and painted wallboard surface coupons were seeded with dry aerosolized Bacillus atrophaeus spores and surface concentrations determined. The observed mean rayon swab recovery efficiency from stainless steel was 0.41 with a standard deviation (SD) of +/-0.17 and for painted wallboard was 0.41 with an SD of +/-0.23. Evaluation of a sonication extraction method for the rayon swabs produced a mean extraction efficiency of 0.76 with an SD of +/-0.12. Swab recovery quantitative limits of detection were estimated at 25 colony forming units (CFU) per sample area for both stainless steel and painted wallboard. CONCLUSIONS: The swab sample collection method may be appropriate for small area sampling (10 -25 cm2) with a high agent concentration, but has limited value for large surface areas with a low agent concentration. The results of this study provide information necessary for the interpretation of swab environmental sample collection data, that is, positive swab samples are indicative of high surface concentrations and may imply a potential for exposure, whereas negative swab samples do not assure that organisms are absent from the surfaces sampled and may not assure the absence of the potential for exposure. SIGNIFICANCE AND IMPACT OF THE STUDY: It is critical from a public health perspective that the information obtained is accurate and reproducible. The consequence of an inappropriate public health response founded on information gathered using an ineffective or unreliable sample collection method has the potential for undesired social and economic impact.  相似文献   

14.
The present study investigated the use of whole blood from humans and rats directly for single-cell gel electrophoresis (comet) assay. As little as 20 microl of whole blood was sufficient for comet assay, and the comet images obtained from whole blood were not different from those obtained from isolated lymphocytes. The DNA remained intact up to 4 h at 4 degrees C after isolation and had no observable strand breakage, when whole blood was cryopreserved (at -80 degrees C) in 10% pre-cooled DMSO up to 60 days. To demonstrate that the whole-blood technique could be applied to in vivo studies, we injected rats with a known carcinogen Fe/NTA and measured DNA strand breaks in whole blood in comparison with isolated lymphocytes. We showed that Fe/NTA injection resulted in similar extent of DNA strand breakage in both whole blood and lymphocytes, indicating that whole-blood method can be used for in vivo genotoxic studies. One disadvantage of the whole-blood technique is that whole blood cannot be used for in vitro studies because of the interferences from red blood cell (RBC) components. However, this problem can be overcome by prior hemolysis of RBCs and a brief centrifugation to obtain white blood cells (WBCs), which can then be used for in vitro incubation with genotoxic compounds before comet assay. Overall, this whole-blood technique for comet assay is expected to provide a simple, rapid, and cost-effective alternative for the existing comet assay using isolated lymphocytes in situations such as when time and cost are limiting factors.  相似文献   

15.
Polyester-rayon blend wipes were evaluated for efficiency of extraction and recovery of powdered Bacillus atrophaeus spores from stainless steel and painted wallboard surfaces. Method limits of detection were also estimated for both surfaces. The observed mean efficiency of polyester-rayon blend wipe recovery from stainless steel was 0.35 with a standard deviation of +/-0.12, and for painted wallboard it was 0.29 with a standard deviation of +/-0.15. Evaluation of a sonication extraction method for the polyester-rayon blend wipes produced a mean extraction efficiency of 0.93 with a standard deviation of +/-0.09. Wipe recovery quantitative limits of detection were estimated at 90 CFU per unit of stainless steel sample area and 105 CFU per unit of painted wallboard sample area. The method recovery efficiency and limits of detection established in this work provide useful guidance for the planning of incident response environmental sampling following the release of a biological agent such as Bacillus anthracis.  相似文献   

16.
Scientists engaged in the research of natural products often either conduct field collections themselves or collaborate with partners who do, such as botanists, mycologists, or SCUBA divers. The information gleaned from such collecting trips (e.g. longitude/latitude coordinates, geography, elevation, and a multitude of other field observations) have provided valuable data to the scientific community (e.g., biodiversity), even if it is tangential to the direct aims of the natural products research, which are often focused on drug discovery and/or chemical ecology. Geographic Information Systems (GIS) have been used to display, manage, and analyze geographic data, including collection sites for natural products. However, to the uninitiated, these tools are often beyond the financial and/or computational means of the natural product scientist. With new, free, and easy-to-use geospatial visualization tools, such as Google Earth, mapping and geographic imaging of sampling data are now within the reach of natural products scientists. The goals of the present study were to develop simple tools that are tailored for the natural products setting, thereby presenting a means to map such information, particularly via open source software like Google Earth.  相似文献   

17.
18.
DNA sensitivity in peripheral blood leukocytes of radar-facility workers daily exposed to microwave radiation and an unexposed control subjects was investigated. The study was carried out on clinically healthy male workers employed on radar equipment and antenna system service within a microwave field of 10 μW/cm2–20 mW/cm2 with frequency range of 1,250–1,350 MHz. The control group consisted of subjects of similar age. The evaluation of DNA damage and sensitivity was performed using alkaline comet assay and chromatid breakage assay (bleomycin-sensitivity assay). The levels of DNA damage in exposed subjects determined by alkaline comet assay were increased compared to control group and showed inter-individual variations. After short exposure of cultured lymphocytes to bleomycin cells of subjects occupationally exposed to microwave (MW) radiation responded with high numbers of chromatid breaks. Almost three times higher number of bleomycin-induced chromatid breaks in cultured peripheral blood lymphocytes were determined in comparison with control group. The difference in break per cell (b/c) values recorded between smokers and non-smokers was statistically significant in the exposed group. Regression analyses showed significant positive correlation between the results obtained with two different methods. Considering the correlation coefficients, the number of metaphase with breaks was a better predictor of the comet assay parameters compared to b/c ratio. The best correlation was found between tail moment and number of chromatid with breaks. Our results indicate that MW radiation represents a potential DNA-damaging hazard using the alkaline comet assay and chromatid breakage assay as sensitive biomarkers of individual cancer susceptibility.  相似文献   

19.
Current studies of human T lymphocytes and their subsets often use quantitative immunofluorescence analysis with monoclonal antibodies against cell surface antigens. With storage of whole blood or separated mononuclear cells for more than a few hours we have found marked changes in lymphocyte analysis using a fluorescence activated cell sorter (FACS). Experiments were done to determine if these lymphocyte changes were influenced by storage temperature and if lymphocytes could be made more stable by addition of culture media RPMI 1640 to whole blood. Optimal conditions found for blood storage were with with addition of 50% RPMI 1640 and with samples held at room temperature (22 degrees C). With these storage conditions, delay on FACS analysis up to 24 hours did not result in spurious results. When blood samples are collected in places remote from the laboratory or when batch analysis of serially collected samples is desirable, excessive storage times should be avoided.  相似文献   

20.
The induction of micronuclei in human cord blood lymphocytes by treatment with gamma-irradiation and bleomycin has been measured. Culture durations which gave peak MN frequencies were determined. The lowest tested doses, 0.1 Gy irradiation and 1.25 micrograms/ml bleomycin, produced significant increases in the frequency of micronuclei. The spontaneous frequency of micronucleated lymphocytes in 28 cord blood samples ranged between 0.5 and 9.5 per thousand lymphocytes, with a modal value of 2.5. The method is evaluated for its potential usefulness in monitoring populations for chromosome breakage.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号