首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 625 毫秒
1.
BackgroundOesophageal changes and injuries were recorded after atrial fibrillation(AF) ablation procedures. The reduction of power in the posterior left atrial(LA) wall(closest to the oesophagus) and the monitoring of temperature in the oesophagus(OE) reduced oesophageal injuries. The intracardiac-echocardiography(ICE) with a Cartosound module provides two-dimensional imaging (2D) to assess detailed cardiac anatomy and its relationship with the OE. The aim of this study was to highlight the safety and feasibility of 3D-reconstruction of the oesophageal course in left atrial catheter ablation(CA) procedures without OE temperature probe or quadripolar catheter to guide ICE OE reconstruction.Methods180 patients(PT) underwent left atrial ablation. AF ablation were 125(69.5%); incisional left atrial tachycardias(IAFL) were 37(20.6%); left atrial tachycardias(LAT) were 19(10.6%). The LA and pulmonary vein anatomies were rendered by traditional electroanatomic mapping(EAM) and merged with an ICE anatomic map. In 109 PT ICE imaging was used to create a geometry of the OE(group A). A quadripolar catheter was used in 71 PT to show OE course associated to ICE(group B).ResultsAblation energy delivery was performed outside the broadest OE anatomy borders. The duration of procedures was longer in group B vs group A Fluoroscopy time was lower in Group A than Group B(Group A 7 ± 3.2 vs 19.2 ± 2.4 min; p < 0.01).ConclusionsOE monitoring with ICE is safe and feasible. Oesophageal anatomy is complex and variable. Many PT will have a broad oesophageal boundary, which increases the risk of untoward thermal injury during posterior LA ablation. ICE with 3D construction of the OE enhances border detection of the OE, and as such, should decrease the risk of oesophageal injury by improving avoidance strategies without intra-oesophageal catheter visualization.  相似文献   

2.

Introduction

Recurrence of atrial fibrillation after pulmonary vein isolation (PVI) occurs frequently and may be associated with electrical reconnection of the pulmonary veins (PV). We investigated spatial distribution of electrical reconnection during re-do procedures in patients with paroxysmal atrial fibrillation who had previous successful acute electrical PVI with either single irrigated tip, antral ablation (s-RF; n = 38) or multi-electrode, duty-cycled ablation (PVAC; n = 48).

Methods and Results

EP navigator, mapping and irrigated tip ablation catheters were used in all re-do procedures. Sites of reconnection were assessed in a 12-segment model. Baseline clinical and demographic characteristics were similar in both groups. The number of PVs reconnected per patient was similar in both groups (2.9 ± 0.9 and 3.2 ± 0.7 (p = 0.193), s?RF and PVAC, respectively), and each PV was equally affected. However, the inferior quadrant of the right lower PV was significantly more vulnerable to reconnection after previous PVAC ablation, whereas the superior quadrant of the right upper PV showed significantly more reconnection in the s?RF group.

Conclusion

The overall number of PVs reconnected was equally high in both groups, and each PV was affected equally. However, there were significant differences in the spatial distribution of electrical reconnection. Better understanding of predilection sites for reconnection might help to improve the long-term success rate of PVI.
  相似文献   

3.
BackgroundSecond-generation cryoballoon ablation is safe and effective in patients with paroxysmal (PAF) and persistent atrial fibrillation (AF).ObjectiveThis study aimed to assess the long-term clinical outcomes and freedom from AF in patients undergoing thermal-guided cryoablation without the use of an electrical mapping catheter.MethodsAll patients who had undergone thermal-guided second-generation cryoablation without electrical mapping between January 2015 and April 2018 at Eastbourne District General Hospital were retrospectively analysed. Success was defined as freedom from atrial arrhythmia lasting >30 s during the follow up period.ResultsThe study included 234 patients with a mean age of 65.3 ± 10.6 years. There were 134 (57.0%) and 100 (42.7%) patients who had PAF and persistent AF respectively.Arrhythmia recurrence occurred in 38 of 134 (28.4%) PAF and 42 of 100 (42.0%) persistent AF patients after mean follow up of 40 ± 9.2 months. The patients with PAF had a significantly greater freedom from arrhythmia than patients with persistent AF (p = .040). The mean procedure time was 55.5 ± 12.2 min and the mean fluoroscopy time was 10.9 ± 4.8 min 73.5% of patients were discharged on the same day.ConclusionThermal-guided cryoablation is feasible, safe and results in freedom from arrhythmia in the majority of paroxysmal and persistent AF patients in the long term. Randomised controlled trials are required to confirm the findings of this study.  相似文献   

4.
Background: Pulmonary vein isolation (PVI) is an established treatment for atrial fibrillation (AF). During PVI an electrical conduction block between pulmonary vein (PV) and left atrium (LA) is created. This conduction block prevents AF, which is triggered by irregular electric activity originating from the PV. However, transmural atrial lesions are required which can be challenging. Re-conduction and AF recurrence occur in 20 - 40% of the cases. Robotic catheter systems aim to improve catheter steerability. Here, a procedure with a new remote catheter system (RCS), is presented. Objective of this article is to show feasibility of robotic AF ablation with a novel system. Materials and Methods: After interatrial trans-septal puncture is performed using a long sheath and needle under fluoroscopic guidance. The needle is removed and a guide wire is placed in the left superior PV. Then an ablation catheter is positioned in the LA, using the sheath and wire as guide to the LA. LA angiography is performed over the sheath. A circular mapping catheter is positioned via the long sheath into the LA and a three-dimensional (3-D) anatomical reconstruction of the LA is performed. The handle of the ablation catheter is positioned in the robotic arm of the Amigo system and the ablation procedure begins. During the ablation procedure, the operator manipulates the ablation catheter via the robotic arm with the use of a remote control. The ablation is performed by creating point-by-point lesions around the left and right PV ostia. Contact force is measured at the catheter tip to provide feedback of catheter-tissue contact. Conduction block is confirmed by recording the PV potentials on the circular mapping catheter and by pacing maneuvers. The operator stays out of the radiationfield during ablation. Conclusion: The novel catheter system allows ablation with high stability on low operator fluoroscopy exposure.  相似文献   

5.
Radiofrequency ablation procedures inside the left atrial appendage (LAA) are likely to involve dangerous complications because of a high thrombogenic effect. Cryoablation procedures are supposed to be safer. We describe two cases of successful cryoablation procedures. Two NavX-guided cryoablations of permanent focal atrial arrhythmias arising from the LAA were performed. Left atrial reconstruction and mapping allowed the zone of the earliest atrial potential to be recorded; the entire course of the ablation catheter was monitored. The arrhythmias were successfully ablated; no thrombotic complications were observed.  相似文献   

6.
Radiofrequency ablation procedures inside the left atrial appendage (LAA) are likely to involve dangerous complications because of a high thrombogenic effect. Cryoablation procedures are supposed to be safer. We describe two cases of successful cryoablation procedures. Two NavX-guided cryoablations of permanent focal atrial arrhythmias arising from the LAA were performed. Left atrial reconstruction and mapping allowed the zone of the earliest atrial potential to be recorded; the entire course of the ablation catheter was monitored. The arrhythmias were successfully ablated; no thrombotic complications were observed.  相似文献   

7.
BackgroundThe new version of inner lumen mapping catheter (Achieve Advance?; Medtronic, Minnesota, USA) includes a new solid core which provides improved rotational response, as compared to the current Achieve Mapping Catheter. In the present study, we sought to analyze the rate of visualisation of real-time recordings using this new device comparing it with a large cohort of patients having undergone second generation cryoballoon (CB) ablation using the previous Achieve mapping catheter.MethodsAll patients having undergone CB ablation using the Achieve Advance and the last 150 consecutive patients having undergone CB ablation using the previous Achieve were analysed. Exclusion criteria were presence of an intracavitary thrombus, uncontrolled heart failure, moderate or severe valvular disease and contraindications to general anesthesia.ResultsA total of 200 consecutive patients (60.1 ± 9.5 years, 75% males) were evaluated (50 Achieve Advance and 150 old Achieve). Real-time recordings were significantly more prevalent in the “new Achieve Advance” population compared with the “old Achieve” group (73.5% vs 56.8%; p = 0.0001). Real-time recordings could be more frequently visualized in the “Achieve Advance” group in all veins except RIPV (LSPV: 86% vs 71.3%, p = 0.04; LIPV: 84% vs 62.7%, p = 0.005; RSPV: 78% vs 52%, p < 0.0001; RIPV: 46% vs 41.3%, p = 0.3).ConclusionsThe rate of visualisation of real-time recordings is significantly higher using the new Achieve Advance if compared to the previous Achieve mapping catheter in the setting of CB ablation. Real-time recordings can be visualized in approximately 73.5% of veins with this new device.  相似文献   

8.

Background

The relationship between focal pulmonary vein potential and atrial fibrillation (AF) has been confirmed. Pulmonary vein (PV) isolation and circumferential pulmonary vein ablation have been the most commonly used procedures of radiofrequency ablation. However, few studies have investigated the relationship between anatomical characteristics of PV and AF recurrences after radiofrequency ablation.

Methodology

For 267 AF patients treated by radiofrequency catheter ablation, the anatomic structure characteristics of pulmonary veins were assessed by multi-slice spiral computed tomography while the values of left atrial diameter (LAD) were measured with transesophageal ultrasonic cardiogram. After radiofrequency catheter ablation, postoperative recurrence was evaluated during a 10-month term follow-up.

Principal Findings

During follow-up, postoperative recurrence occurred in 44 patients. The mean diameters of LAD, left superior PV, right superior PV, all left PV, and all superior PV were significantly larger in patients with postoperative recurrence (Recurrence vs. Non-recurrence group; 43.9 ± 6.4 mm vs. 40.7 ± 5.6 mm; 18.4 ± 2.1 mm vs. 17.1 ± 3.1 mm; 18.2 ± 2.8 mm vs. 17.2 mm ± 3.9 mm; 16.4 ± 1.5 mm vs. 15.6 ± 2.5 mm; 18.3 ± 2.1 mm vs. 17.1 ± 3.0 mm; respectively; all P < 0.05). Multivariable survival analysis showed that the type and the course of AF, LAD, and the diameters of all superior PV were the independent risk factors for the postoperative recurrence after radiofrequency catheter ablation.

Conclusions

The enlargements of all superior PV and LAD, long course of diseases, and persistent AF were the independent risk factors for the postoperative recurrence after radiofrequency catheter ablation.  相似文献   

9.
BackgroundA close association exists between renal impairment (RI) and atrial fibrillation (AF) occurrence. Increased activity of the sympathetic nervous system (SNS) may contribute to the development of AF associated with RI. Renal denervation (RDN) decreases central sympathetic activity.ObjectiveThe main objective of the study was to explore the effects of RDN on AF occurrence and its possible mechanisms in beagles with RI.MethodsUnilateral RI was induced in beagles by embolization of small branches of the renal artery in the right kidney using gelatin sponge granules in Model (n = 6) and RDN group (n = 6). The Sham group (n = 6) underwent the same procedure, except for embolization. Then animals in RDN group underwent radiofrequency ablation of the renal sympathetic nerve. Cardiac electrophysiological parameters, blood pressure, left ventricular end-diastolic pressure, and AF inducibility were investigated. The activity of the SNS, renin-angiotensin-aldosterone system (RAAS), inflammation and atrial interstitial fibrosis were measured.ResultsEmbolization of small branches of the renal artery in the right kidney led to ischemic RI. Heart rate, P wave duration and BP were increased by RI, which were prevented or attenuated by RDN. Atrial effective refractory period was shortened and AF inducibility was increased by RI, which were prevented by RDN. Antegrade Wenckebach point was shortened, atrial and ventricular rates during AF were increased by RI, which were attenuated or prevented by RDN. Levels of norepinephrine, renin and aldosterone in plasma, norepinephrine, angiotensin II, aldosterone, interleukin-6 and high sensitivity C-reactive protein in atrial tissue were elevated, and atrial interstitial fibrosis was enhanced by RI, which were attenuated by RDN.ConclusionsRDN significantly reduced AF inducibility, prevented the atrial electrophysiological changes in a model of RI by combined reduction of sympathetic drive and RAAS activity, and inhibition of inflammation activity and fibrotic pathway in atrial tissue.  相似文献   

10.
Focal discharges (FDs) are present in thoracic veins during atrial fibrillation (AF). We hypothesize that procainamide exerts its anti-AF action by suppressing FDs in the thoracic veins. We studied six mongrel dogs (22-27 kg) with sustained (>6 h) AF induced by 47 +/- 20 days of chronic rapid LA appendage (LAA) or pulmonary vein (PV) pacing. Procainamide was infused intravenously until AF was terminated or a cumulative dose of 20 mg/kg was reached. High-resolution mapping during AF showed FDs in the vein of Marshall, PVs, and the LAA. Procainamide significantly (P < 0.05) reduced the frequency of these FDs and suppressed the interactions of wave fronts between PVs and LA. The cumulative dose of PA needed to terminate AF correlated negatively (r =-0.9, P < 0.05) with the baseline effective refractory period (ERP) of PV and positively (r = 0.8, P < 0.05) with the baseline maximum dominant frequency (DF) of AF. In four of five dogs, AF converted to atrial tachycardia originating from the PVs before termination. Attempts to reinduce sustained AF were unsuccessful in these five dogs. AF was resistant to procainamide in the sixth dog. In conclusion, procainamide reduced the rate of FDs in the thoracic veins and the LA and suppressed the interaction between PVs and LA. Second, FDs in the PV are more resistant to procainamide's action than FDs in the atria. Third, inherent PV ERP is important in determining the antifibrillatory efficacy of procainamide.  相似文献   

11.
A 69-year-old woman with palpitations was referred to our hospital for a second session of atrial fibrillation (AF) catheter ablation. She had a history of AF ablation including pulmonary vein (PV) isolation and persistent left superior vena cava (PLSVC) isolation. Electrophysiologic studies showed the veno-atrial connections that had recovered. After PV isolation was performed, AF was induced by atrial premature contraction (APC) from the PLSVC, and AF storm occurred. During PLSVC isolation, AF was not induced by APC from the PLSVC. PLSVC isolation continued during sinus rhythm. The elimination of the PLSVC potential was difficult to confirm because of the far-field potential of the left ventricle. Then, we performed right ventricular pacing. The remaining PLSVC potential was identified. After that, the PLSVC isolation was successful during right ventricular pacing. Complications were not observed. The patient had no recurrence of AF thereafter.  相似文献   

12.
目的:研究经食道超声心动图(TEE)评估特发性房颤左心房左心耳的临床价值。方法:选择自2015年1月到2016年8月在医院接受诊治的特发性房颤患者100例纳入本次研究,阵发性房颤92例,记为阵发性房颤组;持续性房颤8例,记为持续性房颤组。另选同期在医院进行健康体检的心功能正常志愿者90例作为对照组。利用TEE对受试者进行检查,对比房颤组与对照组的左心房及左心耳参数,是否含有自发性显影(LASEC)的房颤患者的左心房及左心耳参数,利用TEE分析对房颤患者的预后情况。结果:阵发性房颤组左心房的前后径和左右径,左心耳血流最大的排空速度(Lev)均明显小于对照组,左心耳的面积变化率及最大的充盈速度(Lfv)均明显大于对照组,差异有统计学意义(P0.05)。持续性房颤组左心房的前后径和左右径均明显大于对照组,左心耳的面积变化率、Lev及Lfv均明显小于对照组,差异有统计学意义(P0.05)。阵发性房颤组左心房的前后径和左右径均明显小于持续性房颤组,左心耳的面积变化率、Lev及Lfv均明显大于持续性房颤组,差异有统计学意义(P0.05)。有LASEC者左心房的前后径和左右径均明显大于无LASEC者,左心耳的面积变化率、Lev及Lfv均明显小于无LASEC者,差异有统计学意义(P0.05)。100例房颤患者中发现34例LASEC,占34.00%,其中有18例患者合并有左心耳血栓,占18.00%。总计有66例患者接受导管射频消融疗法,占66.00%,均未在术中及术后7d内出现血栓及栓塞并发症。结论:利用TEE对特发性房颤的患者左心房及左心耳进行评估,有利于更好的辅助患者的临床治疗,值得重视。  相似文献   

13.
The parasympathetic (P) nervous system is thought to contribute significantly to focal atrial fibrillation (AF). Thus we hypothesized that P nerve fibers [and related muscarinic (M(2)) receptors] are preferentially located in the posterior left atrium (PLA) and that selective cholinergic blockade in the PLA can be successfully performed to alter vagal AF substrate. The PLA, pulmonary veins (PVs), and left atrial appendage (LAA) from six dogs were immunostained for sympathetic (S) nerves, P nerves, and M(2) receptors. Epicardial electrophysiological mapping was performed in seven additional dogs. The PLA was the most richly innervated, with nerve bundles containing P and S fibers (0.9 +/- 1, 3.2 +/- 2.5, and 0.17 +/- 0.3/cm(2) in the PV, PLA, and LAA, respectively, P < 0.001); nerve bundles were located in fibrofatty tissue as well as in surrounding myocardium. P fibers predominated over S fibers within bundles (P-to-S ratio = 4.4, 7.2, and 5.8 in PV, PLA, and LAA, respectively). M(2) distribution was also most pronounced in the PLA (17.8 +/- 8.3, 14.3 +/- 7.3, and 14.5 +/- 8 M(2)-stained cells/cm(2) in the PLA, PV, and LAA, respectively, P = 0.012). Left cervical vagal stimulation (VS) caused significant effective refractory period shortening in all regions, with easily inducible AF. Topical application of 1% tropicamide to the PLA significantly attenuated VS-induced effective refractory period shortening in the PLA, PV, and LAA and decreased AF inducibility by 92% (P < 0.001). We conclude that 1) P fibers and M(2) receptors are preferentially located in the PLA, suggesting an important role for this region in creation of vagal AF substrate and 2) targeted P blockade in the PLA is feasible and results in attenuation of vagal responses in the entire left atrium and, consequently, a change in AF substrate.  相似文献   

14.
IntroductionWe describe the use of a ablating system to compartmentalise and regionally isolate the atria in paroxysmal and persistent atrial fibrillation (AF).Methods40 patients were studied, 25 paroxysmal AF and 14 persistent AF. One patient enrolled was later found to be in left atrial flutter and was excluded. The Cardima Revelation® TX catheter system with Intellitemp® Radiofrequency (RF) energy control device and a Medtronic Atakar® RF generator were used to place wide area circumferential ablations to achieve conduction block into the left and right sided pulmonary veins. Roof lines and mitral isthmus lines were also performed. In patients with persistent AF and in repeat procedures, right atrial compartmentalisation was performed with an anterior superior vena cava (SVC) to inferior vena cava (IVC) line and a septal SVC to IVC line.ResultsAt 6 months, 18 of the 39 patients were asymptomatic, 10 had improved symptoms and 22 were in sinus rhythm. In the paroxysmal group, 11 were asymptomatic, 7 had improved symptoms and 16 (64%) were in sinus rhythm. In the persistent group, 7 were asymptomatic, 3 had improved symptoms and 6 (43%) were in sinus rhythm. The total group AF burden was 37.8 ± 5.4 hrs pre-procedure and 23.1 ± 5.1 hrs at 6 months post procedure. Mean temperature, impedance and power recorded at each pole demonstrated effective power delivery at all poles. No catheter charring was observed, complication rates were comparable to standard AF ablation technique.ConclusionLinear ablation in the left and right atria to mimic Cox’s Maze is feasible and safe using this ablating system.  相似文献   

15.
BackgroundCryoballoon ablation (CBA) has been proven to be very effective for pulmonary vein (PV) isolation (PVI) if complete occlusion is achieved and conventionally assessed by angiographic injection of contrast within PV lumen. The aim of our study was to assess the usefulness of saline contrast intracardiac echocardiography in guiding CBA with respect to PV angiography.MethodsThirty consecutive patients with paroxysmal atrial fibrillation were randomly assigned fluoroscopy plus color-flow Doppler (n = 15; group 1: an iodinated medium as both angiographic and echographic contrast) or contrast intracardiac echocardiography plus color-flow Doppler (n = 15; group 2: saline contrast) for guidance of CBA.ResultsWe evaluated 338 occlusions of 107 PVs. The intracardiac echocontrastography-guided assessment of occlusion, defined as loss of echocontrastographic back-flow to the left atrium after saline injection regardless of the visualization of PV antrum, showed a high level of agreement with the angiographic diagnosis of occlusion. PVI rate was similar in both groups and effectively guided by intracardiac echocontrastography (PVI using ≤ 2 double cryofreezes: 89% of PVs in group 1 vs. 91% in group 2; p=n.s.). Group 2 patients had significantly shorter procedure (127 ± 16 vs. 152 ± 19 minutes; p<0.05) and fluoroscopy times (30 ± 12 vs. 43 ± 9 minutes, p<0.05) and used a lower iodinated contrast (88 ± 26 vs. 190 ± 47 mL, p<0.05).ConclusionsPV occlusion and PVI during cryoablation can be effectively predicted by intracardiac saline echocontrastography. This technique reduces procedural time, radiological exposure and iodinated contrast use.  相似文献   

16.

Background

Radiofrequency catheter ablations of anteroseptal (AS) accessory pathways (AP) in pediatric patients have higher incidence of atrioventricular (AV) block than other AP locations. We report our experience using cryoablation in pediatric patients where a His bundle electrogram was noted on the ablation catheter at the site of the successful ablation.

Methods and Results

We retrospectively reviewed all patients ≤21 years that underwent cryoablation for an AS AP from 2005 to 2012 at our institution (n=70). Patients with a His bundle electrogram noted on the cryoablation catheter at the location of the successful lesion were identified (n=6, 8.5%). All six patients had ventricular preexcitation. Median age of 15.9 years (7.2 - 18.2). AV nodal function was monitored during the cryoablation with intermittent rapid atrial pacing conducted through the AV node (n=2), with atrial extra-stimulus testing (n=2), or during orthodromic reentrant tachycardia (n=2). Acute success occurred in all patients. Two patients had early recurrence of AP conduction. Both patients underwent a second successful cryoablation, again with a His bundle electrogram on the cryoablation catheter. At a median follow-up of 13 months (3 to 37 months) there was no recurrence of accessory pathway conduction and AVN function was normal.

Conclusion

In a small number of pediatric patients with AS AP with a His bundle electrogram seen on the ablation catheter, the use of cryotherapy was safe and effective for elimination of AP conduction without impairment of AV nodal conduction.  相似文献   

17.
18.
Pulmonary vein (PV) isolation (PVI) techniques have evolved as a curative treatment of atrial fibrillation (AF) since PVI guided by circumferential mapping with a circular catheter was initially proposed. A multielectrode basket catheter (MBC) is also useful for PVI because of some advantages; (1) an MBC provides some information about the PV anatomy on the fluoroscopic image, (2) an MBC can utilize the non-fluoroscopic navigation system, (3) an MBC enables the direct three-dimensional mapping around the PV ostium and antrum, (4) the distal electrodes of the MBC can be used to monitor some activation changes within the PV in real time and thereby indicate the effects of ablation at the ostium and antrum as radiofrequency lesions are created. PVI with an MBC is an effective and safe procedure to cure AF by integrating the PV anatomy and electrophysiology in combination with a non-fluoroscopic three-dimensional navigation system for the ablation catheter.  相似文献   

19.

Background

Pulmonary vein (PV) reconduction after PV isolation (PVI) unmasked by adenosine is associated with a higher risk for paroxysmal atrial fibrillation (PAF) recurrence. It is unknown if the reconnected PVs after adenosine testing and immediate re-ablation can predict reconnection and reconnection patterns of PVs at repeat procedures. We assessed reconnection of PVs with and without dormant-conduction (DC) during the first and the repeat procedure.

Methods

We included 67 patients undergoing PVI for PAF and a second procedure for PAF recurrence. DC during adenosine administration at first procedure was seen in 31 patients (46%). 264 PVs were tested with adenosine; DC was found in 48?PVs (18%) and re-ablated during first procedure. During the second procedure, all PVs where checked for reconnection.

Results

Fifty-eight patients (87%) showed PV reconnection during the second procedure. Reconnection was found in 152/264?PVs (58%). Of 216?PVs without reconnection during adenosine testing at the first ablation, 116?PVs (53.7%) showed reconnection at the repeat procedure. Overall, 14.9% of patients showed the same PV reconnection pattern in the first and second procedure, expected statistical probability of encountering the same reconnection pattern was only 6.6%(p?=?0.012).

Conclusions

In repeat procedures PVs showed significantly more often the same reconnection pattern as during first procedure than statistically expected. More than 50% of initial isolated PVs without reconnection during adenosine testing showed a reconnection during repeat ablation. Techniques to detect susceptibility for PV re-connection like prolonged waiting-period should be applied. Elimination of DC should be expanded from segmental to circumferential re-isolation or vaster RF application.  相似文献   

20.
Catheter instability can limit ablation success of arrhythmia substrates at the right atrioventricular groove. We describe cases where cryoablation improved catheter stability, enabling ablation success.Methods and resultsFour patients with supraventricular tachycardia (SVT) substrates at the right atrioventricular groove had radiofrequency ablation procedures limited by poor catheter contact. Cryoablation offered improved catheter stability, and all four patients achieved acute ablation success using cryoablation. Three patients had long-term success and one patient later required repeat radiofrequency ablation.ConclusionsFor patients with arrhythmia substrates at the right atrioventricular groove, cryoablation may be a useful adjunctive technique in cases with catheter instability.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号