首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
This review discusses the most recent developments and future challenges in the application of solid phase microextraction (SPME) for sampling of live biological samples. The emphasis is placed on applications of fiber SPME for analysis of volatile emissions and drugs in biological fluids. The method development section highlights the main parameters that need to be considered in the case of in vivo experiments: extraction techniques, selection of extraction phases, calibration procedures, determination of free concentrations, and automation.  相似文献   

2.
Modern extraction techniques, supercritical fluid extraction (SFE) and solid-phase microextraction (SPME) were used for isolation of four corticosteroids from biological matrices. SFE was applied for extraction from solid matrices--hydromatrix and pig muscle. The effects of various extraction conditions were studied. Good recoveries of corticosteroids from hydromatrix were obtained under moderate extraction conditions and without modification of carbon dioxide. On the contrary, the best recoveries from spiked pig muscle were obtained with modified carbon dioxide. SPME was used for extraction from liquid samples--water and urine. The eventuality of the use of this fast solvent-free technique in steroid analysis is demonstrated. Several extraction conditions were optimized. Extracted steroids were analyzed by HPLC-UV and a special SPME-HPLC interface was used for combination with SPME.  相似文献   

3.
Solid-phase microextraction (SPME) has gained widespread acceptance for analyte-matrix separation and preconcentration. SPME is a simple, effective adsorption/desorption technique that eliminates the need for solvents or complicated apparatus for concentrating volatile or non-volatile compounds in liquid samples or headspace. SPME is compatible with analyte separation/detection by gas chromatography and high performance liquid chromatography and provides linear results for a wide range of concentrations of analytes. By controlling the polarity and thickness of the coating on the fiber, maintaining consistent sampling time, and adjusting several other extraction parameters, an analyst can ensure highly reliable results for low concentrations of analytes. This review provides updated information on SPME with chromatographic separation for the extraction and measurement of different analytes in biological fluids and materials. Firstly the background to the technique is given in terms of apparatus, fibers used, extraction conditions and derivatisation procedures. Then the different matrices, urine, blood, breast milk, hair and saliva are considered separately. Finally, the future potential of SPME for the analysis of biological samples in terms of the development of new devices and fiber chemistries as well as applications for in vivo studies are discussed.  相似文献   

4.
Headspace-solid phase microextraction (HS-SPME) was studied and optimised for the determination of four common organophosphorus pesticides (OPPs) in biological samples. Various parameters controlling SPME were studied: choice of SPME fiber, type and content of salt added, preheating and extraction time, desorption time, extraction temperature. Capillary gas chromatographic analysis with nitrogen phosphorus detection (GC-NPD) facilitates sensitive and selective detection of the OPPs: malathion, parathion, methyl parathion and diazinon. Fenitrothion was used as the internal standard. The method was applied to the determination of the pesticides in human biological specimens: whole blood, blood plasma, urine, cerebrospinal fluid, liver and kidney. Limits of detection ranged from 2 to 55 ng/ml depending on pesticide and type of specimen. The developed methodology overcomes limitations and obstacles of conventional methods such as the use of organic solvents, the formation of emulsions and the tedious-cumbersome procedures. The proposed protocol is seen as an attractive alternative to be used in routine toxicological analysis.  相似文献   

5.
Organophosphorus pesticides (OPPs), widely known as persistent organic pollutants, are the most popular contaminants in agriculture products in developing countries. The determination of OPPs in complex matrices, such as food, environmental and biological samples, usually requires extensive sample pretreatment. This review focuses on the sorptive extraction techniques applied as sample pretreatment for OPPs in complex matrices, including solid-phase extraction (SPE) and solid-phase microextraction (SPME). These methods are evaluated and the applications of each technique are demonstrated extensively with many practical examples.  相似文献   

6.
This protocol for in vivo solid-phase microextraction (SPME) can be used to monitor and quantify intravenous concentrations of drugs and metabolites without the need to withdraw a blood sample for analysis. The SPME probe is inserted directly into a peripheral vein of a living animal through a standard medical catheter, and extraction occurs typically over 2-5 min. After extraction, the analytes are removed from the sorbent and analyzed by, for example, liquid chromatography-tandem mass spectrometry. It has been validated in comparison with conventional blood analysis, and we describe here the in vitro experiments typically conducted during method development. The new-generation biocompatible SPME probes are designed specifically for extraction of semi-volatiles and nonvolatiles directly from aqueous samples and can be steam sterilized. Sorbents are coated on fine-gauge surgical steel wire (200-μm diameter), which is more rugged and biocompatible than conventional fibers (100-μm fused silica fiber). They incorporate a binding agent that resists fouling by the biological matrix and does not cause an immune response in the experimental animal. The sorbents used (coating thickness of ~50 μm) are selected for their affinity for the types of small molecules of interest. The procedure is illustrated by the analysis of benzodiazepines with polypyrrole-coated wires inserted into peripheral blood vessels of beagles, although it can be adapted for use in smaller animals. The in vivo sampling can require as little as 1 min, in which case the entire procedure from sampling to instrumental analysis can take as little as 30 min.  相似文献   

7.
A solid phase microextraction (SPME) method followed by LC-MS/MS analysis was developed to determine the concentration of tranexamic acid (TA) in plasma. The use of a new biocompatible C18 coating allowed the direct extraction from complex biological samples without prior sample preparation; no matrix effect was observed. The results revealed that SPME was suitable for the analysis of polar drugs such as TA; such an application was previously inaccessible because of the limited availability of SPME coatings that can extract polar molecules. The proposed method was validated according to the bioanalytical method validation guidelines. LOD and LLOQ were 0.5 and 1.5 μg/ml, respectively. The recovery for the method was 0.19%, and the accuracy and precision of the method were <9 and <11%, respectively, with the exception of LLOQ, where the values were <16 and <13%, respectively. The performance of the proposed method was also compared against that of the standard techniques of protein precipitation and ultrafiltration. A statistical analysis indicated a clinically significant agreement among all assays. Another advantage of SPME over conventional techniques was the easy automation and feasibility of in vivo analysis; this advantage makes it possible to use the proposed method for an on-site analysis in clinical practice.  相似文献   

8.
The diagnostic potential and health implications of volatile organic compounds (VOCs) present in human feces has begun to receive considerable attention. Headspace solid-phase microextraction (SPME) has greatly facilitated the isolation and analysis of VOCs from human feces. Pioneering human fecal VOC metabolomic investigations have utilized a single SPME fiber type for analyte extraction and analysis. However, we hypothesized that the multifarious nature of metabolites present in human feces dictates the use of several diverse SPME fiber coatings for more comprehensive metabolomic coverage. We report here an evaluation of eight different commercially available SPME fibers, in combination with both GC-MS and GC-FID, and identify the 50/30 μm CAR-DVB-PDMS, 85 μm CAR-PDMS, 65 μm DVB-PDMS, 7 μm PDMS, and 60 μm PEG SPME fibers as a minimal set of fibers appropriate for human fecal VOC metabolomics, collectively isolating approximately 90% of the total metabolites obtained when using all eight fibers. We also evaluate the effect of extraction duration on metabolite isolation and illustrate that ex vivo enteric microbial fermentation has no effect on metabolite composition during prolonged extractions if the SPME is performed as described herein.  相似文献   

9.
Solid-phase microextraction (SPME) is under investigation for its usefulness in the determination of a widening variety of volatile and semivolatile analytes in biological fluids and materials. Semivolatiles are increasingly under study as analytical targets, and difficulties with small partition coefficients and long equilibration times have been identified. Amphetamines were selected as semivolatiles exhibiting these limitations and methods to optimize their determination were investigated. A 100- micro m polydimethylsiloxane (PDMS)-coated SPME fiber was used for the extraction of the amphetamines from human urine. Amphetamine determination was made using gas chromatography (GC) with flame-ionization detection (FID). Temperature, time and salt saturation were optimized to obtain consistent extraction. A simple procedure for the analysis of amphetamine (AMP) and methamphetamine (MA) in urine was developed and another for 3,4-methylenedioxyamphetamine (MDA), 3,4-methylenedioxy-N-methamphetamine (MDMA) and 3,4-methylenedioxy-N-ethylamphetamine (MDEA) using headspace solid-phase microextraction (HS-SPME) and GC-FID. Higher recoveries were obtained for amphetamine (19.5-47%) and methamphetamine (20-38.1%) than MDA (5.1-6.6%), MDMA (7-9.6%) and MDEA (5.4-9.6%).  相似文献   

10.
This work evaluates the utility of solid-phase microextraction (SPME) in the analysis of amphetamines by liquid chromatography (LC) after chemical derivatization of the analytes. Two approaches have been tested and compared, SPME followed by on-fiber derivatization of the extracted amphetamines, and solution derivatization followed by SPME of the derivatives formed. Both methods have been applied to measure amphetamine (AP), methamphetamine (MA), and 3,4-methylenedioxymethamphetamine (MDMA), using the fluorogenic reagent 9-fluorenylmethyl chloroformate (FMOC) and carbowax-templated resin (CW-TR)-coated fibers. Data on the application of the proposed methods for the analysis of different kind of samples are presented. When analyzing aqueous solutions of the analytes, both approaches gave similar analytical performance, but the sensitivity attainable with the solution derivatization/SPME method was better. The efficiencies observed when processing spiked urine samples by the SPME/on-fiber derivatization approach were very low. This was because the extraction of matrix components into the fiber coating prevented the extraction of the reagent. In contrast, the efficiencies obtained for spiked urine samples by the solution derivatization/SPME approach were similar to those obtained for aqueous samples. Therefore, the later method would be the method of choice for the quantification of amphetamines in urine.  相似文献   

11.
Geosmin is a volatile fungal metabolite with an earthy aroma produced in grape products from rotten grapes. The accumulation of geosmin in grapes is caused by the interaction of Botrytis cinerea and Penicillium expansum. Solid Phase Microextraction (SPME) has great utility for collecting volatile compounds in wine. However, contamination with earthy odours may have occurred previously in the must and novel methods are required for this commodity. In the present report, several parameters of the SPME were evaluated to optimize geosmin extraction. The method permitted quantification of geosmin and other fungal volatiles by Gas Chromatography-Mass Spectrometer (GC-MS) at very low concentrations. Limits of detection and quantification (LD and LQ) for geosmin were 4.7 ng L−1 and 15.6 ng L−1 respectively. The RSD was 4.1% and the recovery rates ranged from 115% to 134%. Uniquely, haloanisoles were analyzed by using only one internal standard (2,3,6-trichloroanisole) thus avoiding the synthesis of deuterated anisole analogues that are used as internal standard in other methods. The method was used for the analysis of grape juice samples inoculated with B. cinerea and P. expansum. Geosmin and methylisoborneol were the compounds that appeared to contribute most to earthy odours, although other fungal compounds which are claimed to cause earthy or mouldy off-odours were detected (e.g. 1-octen-3-ol and fenchol).  相似文献   

12.
A poly (methacrylic acid-ethylene glycol dimethacrylate, MAA-EGDMA) monolithic capillary was used for the in-tube solid-phase microextraction (in-tube SPME) of several angiotensin II receptor antagonists (ARA-IIs) from human plasma and urine. Under the optimized extraction condition, the protein component of the biological sample was flushed through the monolithic capillary, while the analytes were successfully trapped. Coupled to HPLC with fluorescence detection, this on-line in-tube SPME method was successfully applied for the determination of candesartan, losartan, irbesartan, valsartan, telmisartan, and their detection limits were found to be 0.1-15.3ng/mL and 0.1-15.2ng/mL in human plasma and urine, respectively. The method was linear over the range of 0.5-200ng/mL for telmisartan, 5-2000ng/mL for candesartan and irbesartan, 10-2000ng/mL for valsartan, and 50-5000ng/mL for losartan with correlation coefficients being above 0.9985 in plasma sample and above 0.9994 in urine sample. The method reproducibility was evaluated at three concentration levels, resulting in the R.S.D. <7%. The poly (MAA-EGDMA) monolithic capillary was demonstrated to be robust and biocompatible by using direct injections of biological samples.  相似文献   

13.
This paper reviews new developments in multiple headspace extraction (MHE), especially its combination with two miniaturized extraction techniques, solid-phase microextraction (SPME) and single-drop microextraction (SDME). The combination of the techniques broadens the applicability of SPME and SDME to quantitative determination of analytes in complex liquid and solid matrixes. These new methods offer several advantages over traditional liquid-solid, liquid-liquid and headspace extraction techniques. The potential applications include extraction of volatiles and semivolatiles from environmental and physiological samples and from different polymer products such as medical and biomedical materials, food packaging and building materials. The theoretical principals of the techniques are also briefly reviewed.  相似文献   

14.
This paper reviews new developments in multiple headspace extraction (MHE), especially its combination with two miniaturized extraction techniques, solid-phase microextraction (SPME) and single-drop microextraction (SDME). The combination of the techniques broadens the applicability of SPME and SDME to quantitative determination of analytes in complex liquid and solid matrixes. These new methods offer several advantages over traditional liquid–solid, liquid–liquid and headspace extraction techniques. The potential applications include extraction of volatiles and semivolatiles from environmental and physiological samples and from different polymer products such as medical and biomedical materials, food packaging and building materials. The theoretical principals of the techniques are also briefly reviewed.  相似文献   

15.
A simple and rapid method based on solid phase microextraction (SPME) via direct immersion followed by gas chromatography coupled with electron impact ionization/mass spectrometry (GC/EI-MS) was developed for the determination of strychnine in blood. Papaverine was used as internal standard (I.S.). Two types of fibre coating were tested, 100 microm polydimethylsiloxane and 65 microm Carbowax/Divinylbenzene, the latter giving higher recoveries of the compound. The main factors affecting the SPME process, such as sample dilution (1:10), adsorption and desorption times (20 and 10 min, respectively), carry-over effect (not observed), pH and salt addition (no modifications on pH or salt concentration) were optimized. The procedure was validated in terms of linearity (r(2)=0.9992 for concentrations ranging from 0.10 to 5.00 microg/mL), intra and interday precision (0.93 and 4.62%, respectively at 0.50 microg/mL; 3.33 and 8.06%, respectively at 2.50 microg/mL), sensitivity (6.83 and 8.91 ng/mL for LOD and LOQ, respectively) and extraction recovery (0.54 and 0.39% at 0.50 and 2.50 microg/mL, respectively). The developed procedure was found suitable for forensic investigations and was considered a good alternative to the liquid-liquid extraction methods normally used for the determination of this compound in biological media.  相似文献   

16.
Methodology using MAE/SPME/GC-MS is being pursued for the analysis of organic pollutants in sebum. The microwave-assisted extraction (MAE) of standards of semi volatile organic pollutants from sebum was optimized. All compounds were extracted from sebum with recoveries analyzed by GC/MS ranging from 94% to 100% under the optimum MAE conditions: 10mL acetone-hexane (2:1), 60 degrees C, and 10 min microwave heating. To improve the detection limits a SPME procedure was optimized. Linearity ranged from 0.70 ppb to 25 ppb. R.S.D. were in the range of 1-23% for the SPME step. Preliminary real samples were analyzed and a range of compounds was detected. The optimized MAE/SPME/GC-MS methodology promises to be useful for different applications.  相似文献   

17.
In the present work, solid-phase microextraction (SPME) and gas chromatography-mass spectrometry (GC-MS) was developed for investigation of lung cancer volatile biomarkers. Headspace SPME conditions (fiber coating, extraction temperature and extraction time) and desorption conditions were optimized and applied to determination of volatiles in human blood. To find the biomarkers of lung cancer, investigation of volatile compounds in lung cancer blood and control was performed by using the present method. Concentrations of hexanal and heptanal in lung cancer blood were found to be much higher than those in control blood. The two molecules of hexanal and heptanal were regarded as biomarkers of lung cancer. By comparison of volatiles in breath and in blood, it is demonstrated that hexanal and heptanal in breath were originated from blood and screening of lung cancer by breath analysis be feasible. These results show that SPME/GC-MS is a simple, rapid and sensitive method very suitable for investigation of volatile disease markers in human blood.  相似文献   

18.
Solid-phase extraction (SPE) procedures for pesticide residues in food and environment are reviewed and discussed. The use of these procedures, which include several approaches such as: matrix solid-phase dispersion (MSPD), solid-phase micro-extraction (SPME) and stir-bar sorptive extraction (SBSE), represents an opportunity to reduce analysis time, solvent consumption, and overall cost. SPE techniques differ from solvent extraction depending on the interactions between a sorbent and the pesticide. This interaction may be specific for a particular pesticide, as in the interaction with an immunosorbent, or non-specific, as in the way a number of different pesticides are adsorbed on apolar or polar materials. A variety of applications were classified according to the method applied: conventional SPE, SPME, hollow-fiber micro-extraction (HFME), MSPD and SBSE. Emphasis is placed on the multiresidue analysis of liquid and solid samples.  相似文献   

19.
The volatile composition of seven honey samples collected from various regions of Algeria and feeding on different plants have been determined. The Headspace Solid‐Phase MicroExtraction (HS‐SPME) coupled with Gas Chromatography‐Mass Spectrometry (GC/MS) was used to achieve the purpose. In this work, different parameters of the HS‐SPME analytical method were investigated in order to reach maximal sensitivity, and thus to obtain maximum information about the volatile profile of Algerian honey. These parameters include saline medium, HS extraction temperature, and the nature of the fiber used. The results showed a great diversity in the chemical composition, in total 124 compounds from different chemical classes were identified, including compounds found for the first time in honey. The Ascending Hierarchical Classification (AHC) demonstrated the importance of choosing SPME extraction conditions to find volatile compounds, which could be as specific markers of the floral or geographical origin of honey, the latter was optimized in the parameter PDMS‐55 °C.  相似文献   

20.
Solid-phase extraction (SPE) procedures for pesticide residues in food and environment are reviewed and discussed. The use of these procedures, which include several approaches such as: matrix solid-phase dispersion (MSPD), solid-phase micro-extraction (SPME) and stir-bar sorptive extraction (SBSE), represents an opportunity to reduce analysis time, solvent consumption, and overall cost. SPE techniques differ from solvent extraction depending on the interactions between a sorbent and the pesticide. This interaction may be specific for a particular pesticide, as in the interaction with an immunosorbent, or non-specific, as in the way a number of different pesticides are adsorbed on apolar or polar materials. A variety of applications were classified according to the method applied: conventional SPE, SPME, hollow-fiber micro-extraction (HFME), MSPD and SBSE. Emphasis is placed on the multiresidue analysis of liquid and solid samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏