首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Transthoracic Doppler echocardiography (TTDE) is a clinically useful, noninvasive tool for studying coronary artery flow velocity and coronary flow reserve (CFR) in humans. Reduced CFR is accompanied by marked intramyocardial and pericoronary fibrosis and is used as an indication of the severity of dysfunction. This study explores, step-by-step, the real-time changes measured in the coronary flow velocity, CFR and systolic to diastolic peak velocity (S/D) ratio in the setting of an aortic banding model in mice. By using a Doppler transthoracic imaging technique that yields reproducible and reliable data, the method assesses changes in flow in the septal coronary artery (SCA), for a period of over two weeks in mice, that previously either underwent aortic banding or thoracotomy. During imaging, hyperemia in all mice was induced by isoflurane, an anesthetic that increased coronary flow velocity when compared with resting flow. All images were acquired by a single imager. Two ratios, (1) CFR, the ratio between hyperemic and baseline flow velocities, and (2) systolic (S) to diastolic (D) flow were determined, using a proprietary software and by two independent observers. Importantly, the observed changes in coronary flow preceded LV dysfunction as evidenced by normal LV mass and fractional shortening (FS). The method was benchmarked against the current gold standard of coronary assessment, histopathology. The latter technique showed clear pathologic changes in the coronary artery in the form of peri-coronary fibrosis that correlated to the flow changes as assessed by echocardiography. The study underscores the value of using a non-invasive technique to monitor coronary circulation in mouse hearts. The method minimizes redundant use of research animals and demonstrates that advanced ultrasound-based indices, such as CFR and S/D ratios, can serve as viable diagnostic tools in a variety of investigational protocols including drug studies and the study of genetically modified strains.  相似文献   

2.
The blood flow velocities in left anterior descending coronary artery and ascending aorta have been measured in anesthetized rats by high frequency Doppler technique. The measurement of coronary blood flow velocity by miniature ultrasonic probe (2.0 x 1.5 mm) was performed through myocardial surface. Two different forms of coronary blood flow curves were recorded. These forms of the curves depend on the value of the coronary blood flow velocity and are connected with the ascending aorta blood flow velocity. The dynamics of the coronary blood flow reactions under coronary artery occlusion and asphyxia in the rat is similar to the one in the cat and the dog, but less expressive. In experiments with vasodilators the direct dependence between linear and volume coronary artery velocities under the measurement through myocardial surface was found.  相似文献   

3.
The radioactive microsphere technique was used to study mechanisms of disappearance of myocardial ischemia during partial occlusion of the left descending anterior coronary artery with implanted device in conscious immobilized rabbits. Microspheres (15 microns, NEN, USA) were injected before occlusion, immediately after ST-segment elevation and after disappearance of ST-segment shift. In ischemic region blood flow dropped by 45% (p less than 0.05) and mean blood pressure decreased by 12% (P less than 0.05) on the 1st minute of coronary occlusion. 8-15 min later ST-segment elevation disappeared and the blood flow in ischemic region became higher than control level (on the average by 35%). It is suggested that ischemia is abolished mainly by dilatation of distal coronary vessels, than by activation of collateral blood flow.  相似文献   

4.
A technique for measurement of retrograde coronary blood flow in intact anesthetized dogs is described. Occlusion of the coronary artery is produced by the inflation of a small rubber balloon at the tip of a no. 9 cardiac catheter placed under fluorescopy in a branch of the left coronary artery. Blood which bleeds back from the occluded coronary artery through the no. 9 catheter is diverted into a small reservoir of 1-ml capacity. The time to fill this reservoir is recorded electrically. Retrograde coronary blood flow is calculated from the time required to fill this reservoir. Results indicate good repeatability of meadurements. The technique seems to be a simple, adequate, and convenient means for assessing agents for possible vasodilator action on the collateral circulation in intact animals.  相似文献   

5.
This study tested the hypothesis that 5-HT may impair coronary flow regulation by inappropriately increasing arteriolar tone in the coronary circulation. Ten closed chest, domestic swine were studied both in the presence and in the absence of a severe artificial intraluminal coronary stenosis. A 5-French micromanometer catheter with fluid lumen was placed in the left anterior descending coronary artery and used to record pressure and infuse 5-HT (40 and 100 micrograms/min) into the coronary circulation. For the stenosis phase of the protocol the catheter was embedded in the artificial stenosis. Hemodynamics, regional myocardial blood flow (microsphere technique), coronary vascular resistance, lactate consumption, and oxygen metabolism were measured at control and at 5 min of each 5-HT dose. In the absence of coronary artery stenosis (i.e., full vasodilatory reserve), there was no change in regional myocardial blood flow or coronary vascular resistance during 5-HT infusion. In the presence of a severe coronary stenosis (i.e., limited vasodilator reserve) 5-HT produced a significant (P less than 0.05) decrease versus control in the distal left anterior descending: circumflex zone endocardial blood flow ratio (0.63 +/- 0.19, mean +/- 1 SD, to 0.55 +/- 0.15) and a significant (P less than 0.05) increase versus control in endocardial (50.6 +/- 16.6 to 61.2 +/- 19.8 mm Hg/ml/min/g) and transmural (49.9 +/- 9.5 to 57.2 +/- 12.8) coronary vascular resistance. Thus, 5-HT does not impair coronary flow regulation when full vasodilatory reserve is present. When coronary vasodilatory reserve is impaired by the presence of a severe proximal stenosis, 5-HT causes modest impairment of endocardial flow regulation.  相似文献   

6.
Blood flow dynamics in the human right coronary artery have not been adequately quantified despite the clinical significance of coronary atherosclerosis. In this study, a technique was developed to construct a rigid flow model from a cast of a human right coronary artery. A laser photochromic method was used to characterize the velocity and wall shear stress patterns. The flow conditions include steady flow at Reynolds numbers of 500 and 1000 as well as unsteady flow with Womersley parameter and peak Reynolds number of 1.82 and 750, respectively. Characterization of the three-dimensional geometry of the artery revealed that the largest spatial variation in curvature occurred within the almost branch-free proximal region, with the greatest curvature existing along the acute margin of the heart. In the proximal segment, high shear stresses were observed on the outer wall and lower, but not negative, stresses along the inner wall. Low shear stress on the inner wall may be related to the preferential localization of atherosclerosis in the proximal segment of the right coronary artery. However, it is possible that the large difference between the outer and inner wall shear stresses may also be involved.  相似文献   

7.
8.
A technique is described for simple flow assessment of the in situ radial artery conduit during coronary bypass via a small incision. This technique allows morphologic and physiologic direct intraoperative assessment of radial artery quality and expands the use of radial artery during coronary artery surgery.  相似文献   

9.
A validation study and early results for non-invasive, in vivo measurement of coronary artery blood flow using phase contrast magnetic resonance imaging (PC-MRI) at 3.0T is presented. Accuracy of coronary artery blood flow measurements by phase contrast MRI is limited by heart and respiratory motion as well as the small size of the coronary arteries. In this study, a navigator echo gated, cine phase velocity mapping technique is described to obtain time-resolved velocity and flow waveforms of small diameter vessels at 3.0T. Phantom experiments using steady, laminar flow are presented to validate the technique and show flow rates measured by 3.0T phase contrast MRI to be accurate within 15% of true flow rates. Subsequently, in vivo scans on healthy volunteers yield velocity measurements for blood flow in the right, left anterior descending, and left circumflex arteries. Measurements of average, cross-sectional velocity were obtainable in 224/243 (92%) of the cardiac phases. Time-averaged, cross-sectional velocity of the blood flow was 6.8+/-4.3cm/s in the LAD, 8.0+/-3.8cm/s in the LCX, and 6.0+/-1.6cm/s in the RCA.  相似文献   

10.
Structural coronary microcirculation abnormalities are important prognostic determinants in clinical settings. However, an assessment of microvascular resistance (MR) requires a velocity wire. A first-pass distribution analysis technique to measure volumetric blood flow has been previously validated. The aim of this study was the in vivo validation of the MR measurement technique using first-pass distribution analysis. Twelve anesthetized swine were instrumented with a transit-time ultrasound flow probe on the proximal segment of the left anterior descending coronary artery (LAD). Microspheres were injected into the LAD to create a model of microvascular dysfunction. Adenosine (400 μg·kg(-1)·min(-1)) was used to produce maximum hyperemia. A region of interest in the LAD arterial bed was drawn to generate time-density curves using angiographic images. Volumetric blood flow measurements (Q(a)) were made using a time-density curve and the assumption that blood was momentarily replaced with contrast agent during the injection. Blood flow from the flow probe (Q(p)), coronary pressure (P(a)), and right atrium pressure (P(v)) were continuously recorded. Flow probe-based normalized MR (NMR(p)) and angiography-based normalized MR (NMR(a)) were calculated using Q(p) and Q(a), respectively. In 258 measurements, Q(a) showed a strong correlation with the gold standard Q(p) (Q(a) = 0.90 Q(p) + 6.6 ml/min, r(2) = 0.91, P < 0.0001). NMR(a) correlated linearly with NMR(p) (NMR(a) = 0.90 NMR(p) + 0.02 mmHg·ml(-1)·min(-1), r(2) = 0.91, P < 0.0001). Additionally, the Bland-Altman analysis showed a close agreement between NMR(a) and NMR(p). In conclusion, a technique based on angiographic image data for quantifying NMR was validated using a swine model. This study provides a method to measure NMR without using a velocity wire, which can potentially be used to evaluate microvascular conditions during coronary arteriography.  相似文献   

11.
A physiological role of carbon monoxide has been suggested for coronary myocytes; however, direct evidence is lacking. The objective of this study was to test the effect of chronic carbon monoxide exposure on the K(+) currents of the coronary myocytes. The effect of 3-wk chronic exposure to carbon monoxide was assessed on K(+) currents in isolated rat left coronary myocytes by the use of the patch-clamp technique in the whole cell configuration. Moreover, membrane potential studies were performed on coronary artery rings using intracellular microelectrodes, and coronary blood flow in isolated heart preparation was recorded. Carbon monoxide did not change the amplitude of global whole cell K(+) current, but it did increase the component sensitive to 1 mM 4-aminopyridine. Carbon monoxide exposure hyperpolarized coronary artery segments by approximately 10 mV and, therefore, increased their sensitivity to 4-aminopyridine. This effect was associated with an enhancement of coronary blood flow. We conclude that chronic carbon monoxide increases a 4-aminopyridine-sensitive current in isolated coronary myocytes. This mechanism could, in part, contribute to hyperpolarization and to increased coronary blood flow observed with carbon monoxide.  相似文献   

12.
Coronary flow reserve (CFR) and fractional flow reserve (FFR) are important physiological indexes for coronary disease. The purpose of this study was to validate the CFR and FFR measurement techniques using only angiographic image data. Fifteen swine were instrumented with an ultrasound flow probe on the left anterior descending artery (LAD). Microspheres were gradually injected into the LAD to create microvascular disruption. An occluder was used to produce stenosis. Contrast material injections were made into the left coronary artery during image acquisition. Volumetric blood flow from the flow probe (Q(q)) was continuously recorded. Angiography-based blood flow (Q(a)) was calculated by using a time-density curve based on the first-pass analysis technique. Flow probe-based CFR (CFR(q)) and angiography-based CFR (CFR(a)) were calculated as the ratio of hyperemic to baseline flow using Q(q) and Q(a), respectively. Relative angiographic FFR (relative FFR(a)) was calculated as the ratio of the normalized Q(a) in LAD to the left circumflex artery (LC(X)) during hyperemia. Flow probe-based FFR (FFR(q)) was measured from the ratio of hyperemic flow with and without disease. CFR(a) showed a strong correlation with the gold standard CFR(q) (CFR(a) = 0.91 CFR(q) + 0.30; r = 0.90; P < 0.0001). Relative FFR(a) correlated linearly with FFR(q) (relative FFR(a) = 0.86 FFR(q) + 0.05; r = 0.90; P < 0.0001). The quantification of CFR and relative FFR(a) using angiographic image data was validated in a swine model. This angiographic technique can potentially be used for coronary physiological assessment during routine cardiac catheterization.  相似文献   

13.
Removal of exogenously administered rat ANF (99-126) (rANF) from the rabbit coronary vasculature was investigated. Rabbit hearts were perfused using a modified Langendorff technique and ANF concentrations in the perfusate were measured by a radio-receptor assay. Under these conditions no major degradation of ANF was observed. On perfusion, however, the heart liberated large amounts of ANF. This release peaked 15 minutes after the initiation of perfusion, (685 + 220 pM) and then fell to a sustained basal level (305 + 80 pM) after 45 minutes. Although an increase in the perfusate flow rate reduced the ANF concentration, there was no significant difference in the rate of ANF release between the two flow rates used. After momentary cessation of flow ANF concentration fell to a significantly lower level, however, once again no significant change in rate of release occurred. These results suggest that the heart is not a major site of ANF degradation and that alterations in flow rate through the coronary vascular bed can cause changes in amounts of ANF released.  相似文献   

14.
A simplified technique with the use of intraluminal vessel occluders to prevent collateral flow of blood and cardioplegic solution during saphenous vein distal coronary artery anastomosis is presented here. Additional advantages of this technique are the stenting of vessels to facilitate vessel approximation and the assurance of anastomotic patency.  相似文献   

15.
The effect of plasma volume expansion on transcapillary exchange and norepinephrine release in the heart was examined in pentobarbital sodium-anesthetized dogs by use of the multiple indicator-dilution technique. Animals were studied under basal conditions and following infusion of the plasma expander, dextran. Catheters were placed in coronary artery and coronary sinus in a closed-chest preparation. Labeled albumin, sucrose, and norepinephrine were injected into the coronary artery and outflow-dilution curves were secured. Analysis of these provided parameters reflecting coronary flow and permeability-surface product, and a norepinephrine tracer kinetic-bulk model provided simultaneous estimates of the rate of norepinephrine release into the myocardial interstitial space. The infusion of dextran resulted in a large increase in coronary flow without significant changes in myocardial norepinephrine release; at the same time the permeability-surface product values increased, amplifying the capacity of the higher flow to deliver substrates to sarcolemmal cells. The findings indicate that plasma volume expansion increases transcapillary exchange in the heart without activating the cardiac sympathetic system.  相似文献   

16.
A cannulation technique for creating a nonobstructive port in a proximal coronary artery is described. The use of this technique in awake animals allows the blood pressure to be measured in a coronary artery distal to an experimentally produced stenosis. This port can also be used to inject drugs directly into the coronary bed.  相似文献   

17.
The instantaneous and continuous interrelationship between coronary blood flow and coronary venous O2 saturation was determined during transient periods following abrupt rate change in the electrically paced canine heart. Through a catheter in the coronary sinus, O2 saturation was continuously monitored using a fibreoptics technique, and venous flow was measured with an electromagnetic flowmeter. Various patterns of change in flow and O2 saturation were observed depending both on the absolute values of the cardiac rates as well as on the relative difference between them during changes from one rate to another. Whereas elevation of coronary flow was monophasic when the magnitude of heart rate change was below 75 beats per minute, a drop in flow was observed preceeding its elevation when the difference was greater. At high rates further increase in rate caused either no alteration or led to a monophasic drop in flow during the transitional period. Changes in O2 saturation were observed only when heart rate difference exceeded 60 beats per minute. Between 60-90 beats per minute O2 saturation remained steady except during the transient rate elevation, ending in a lower steady state O2 saturation. The results indicate that both O2 saturation and coronary flow change with heart rate initially because of mechanical consequence of the increased rate on the myocardium, and later according to its new metabolic needs also manifested by changed O2 extraction.  相似文献   

18.
This study explored the hypothesis that coronary vascular injury and dysfunction result from intracoronary administration of Escherichia coli endotoxin (0.025 to 0.025 to 0.4 mg/kg) in dogs. Peak hyperemic coronary flow following a 15-sec period of stopped flow and the maximum flow in response to adenosine were used to estimate coronary vascular reserve. The wet-to-dry ratio of myocardial tissue was used to estimate extravascular water content as an indicator of vascular leak due to endothelial injury. Intracoronary saline was used as a control. Peak reactive hyperemia and maximum flow at constant coronary pressure were not different in the animals receiving intracoronary endotoxin (n = 6) and the animals receiving saline (n = 5) during 4 hr following treatment. In addition, wet-to-dry ratios were similar in these two groups. These data fail to support the hypothesis that endotoxin, per se, produces coronary vascular injury of sufficient magnitude to produce myocardial dysfunction.  相似文献   

19.
Few studies have investigated factors responsible for the O2 demand/supply balance in the right ventricle. Resting right coronary blood flow is lower than left coronary blood flow, which is consistent with the lesser work of the right ventricle. Because right and left coronary artery perfusion pressures are identical, right coronary conductance is less than left coronary conductance, but the signal relating this conductance to the lower right ventricular O2 demand has not been defined. At rest, the left ventricle extracts approximately 75% of the O2 delivered by coronary blood flow, whereas right ventricular O2 extraction is only ~50%. As a result, resting right coronary venous PO2 is approximately 30 mm Hg, whereas left coronary venous PO2 is approximately 20 mm Hg. Right coronary conductance does not sufficiently restrict flow to force the right ventricle to extract the same percentage of O2 as the left ventricle. Endogenous nitric oxide impacts the right ventricular O2 demand/supply balance by increasing the right coronary blood flow at rest and during acute pulmonary hypertension, systemic hypoxia, norepinephrine infusion, and coronary hypoperfusion. The substantial right ventricular O2 extraction reserve is used preferentially during exercise-induced increases in right ventricular myocardial O2 consumption. An augmented, sympathetic-mediated vasoconstrictor tone blunts metabolically mediated dilator mechanisms during exercise and forces the right ventricle to mobilize its O2 extraction reserve, but this tone does not limit resting right coronary flow. During exercise, right coronary vasodilation does not occur until right coronary venous PO2 decreases to approximately 20 mm Hg. The mechanism responsible for right coronary vasodilation at low PO2 has not been delineated. In the poorly autoregulating right coronary circulation, reduced coronary pressure unloads the coronary hydraulic skeleton and reduces right ventricular systolic stiffness. Thus, normal right ventricular external work and O2 demand/supply balance can be maintained during moderate coronary hypoperfusion.  相似文献   

20.
Although the TIMI (Thrombolysis In Myocardial Infarction) flow grade classification scheme is widely used to assess angiographic outcomes, it is limited by poor reproducibility and its categoric nature. The corrected TIMI frame count (CTFC) is a simple, more objective continuous variable index of coronary blood flow that can be broadly and inexpensively applied. This measure of the time for dye to traverse a coronary artery is both accurate (highly correlated with Doppler velocity measurements) and precise (reproducible). The method has been prospectively validated as providing independent risk stratification above and beyond the conventional TIMI flow grades. It has been shown to be a predictor of restenosis, and has been of value in elucidating the underlying pathophysiology of acute myocardial infarction. In view of the above and its ease of use, we anticipate that CTFC will become a widely used method to evaluate coronary blood flow.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号