The purpose of this investigation was to examine the effect of leg flexion angle on the relationship between mechanomyographic (MMG) amplitude and isometric torque production. Adult males (n = 9) performed isometric muscle actions of the leg extensors at 25, 50, 75, and 100 percent maximal voluntary contraction (%MVC) on a calibrated CYBEX 6000 dynamometer at 25, 50, and 75° below full extension. A piezoelectric MMG recording device was placed over the mid-portion of the rectus femoris. At 25° of leg flexion, the MMG amplitude increased to 100%MVC. At 50 and 75° of leg flexion, however, MMG amplitude increased to 75%MVC, and then did not change significantly (P > 0.05) between 75 and 100%MVC. These findings indicate that the MMG amplitude-isometric torque relationship is joint angle specific and may be the result of leg flexion angle differences in: (1) muscle stiffness, or (2) motor unit activation strategies. Accepted: 2 March 1998  相似文献   

2.
This study investigated the effects of dynamic knee extension and flexion fatiguing task on torque and neuromuscular responses in young and older individuals. Eighteen young (8 males; 25.1 ± 3.2 years) and 17 older (8 males; 69.7 ± 3.7 years) volunteered. Following a maximal voluntary isometric contraction test, participants performed a fatiguing task involving 22 maximal isokinetic (concentric) knee extension and flexion contractions at 60°/s, while surface EMG was recorded simultaneously from the knee extensors (KE) and flexors (KF). Fatigue-induced relative torque reductions were similar between age groups for KE (peak torque decrease: 25.15% vs 26.81%); however, KF torque was less affected in older individuals (young vs older peak torque decrease: 27.6% vs 11.5%; p < 0.001) and this was associated with greater increase in hamstring EMG amplitude (p < 0.001) and hamstrings/quadriceps peak torque ratio (p < 0.01). Furthermore, KE was more fatigable than KF only among older individuals (peak torque decrease: 26.8% vs 11.5%; p < 0.001). These findings showed that the age-related fatigue induced by a dynamic task was greater for the KE, with greater age-related decline in KE compared to KF.  相似文献   

3.
Objective:This paper presents the analyses of the fatigue effect on the cross-talk in mechanomyography (MMG) signals of extensor and flexor forearm muscles during pre- and post-fatigue maximum voluntary isometric contraction (MVIC).Methods:Twenty male participants performed repetitive submaximal (60% MVIC) grip muscle contractions to induce muscle fatigue and the results were analyzed during the pre- and post-fatigue MVIC. MMG signals were recorded on the extensor digitorum (ED), extensor carpi radialis longus (ECRL), flexor digitorum superficialis (FDS) and flexor carpi radialis (FCR) muscles. The cross-correlation coefficient was used to quantify the cross-talk values in forearm muscle pairs (MP1, MP2, MP3, MP4, MP5 and MP6). In addition, the MMG RMS and MMG MPF were calculated to determine force production and muscle fatigue level, respectively.Results:The fatigue effect significantly increased the cross-talk values in forearm muscle pairs except for MP2 and MP6. While the MMG RMS and MMG MPF significantly decreased (p<0.05) based on the examination of the mean differences from pre- and post-fatigue MVIC.Conclusion:The presented results can be used as a reference for further investigation of cross-talk on the fatigue assessment of extensor and flexor muscles’ mechanic.  相似文献   

4.
Eighteen adults performed isometric muscle actions of the leg extensors at 25, 50, 75, and 100% maximal voluntary contraction (%MVC) at leg flexion angles of 25, 50, and 75 degrees. The results indicated that isometric torque production increased as leg flexion angle increased (75 degrees > 50 degrees > 25 degrees). For each muscle tested (rectus femoris, vastus lateralis, and vastus medialis), the EMG amplitude increased up to 100%MVC at each leg flexion angle (25, 50, and 75 degrees). The MMG amplitude for each muscle, however, increased up to 100%MVC at 25 and 50 degrees of leg flexion, but plateaued from 75 to 100%MVC at 75 degrees of leg flexion. We hypothesize that the varied patterns for the MMG amplitude-isometric torque relationships were due to leg flexion angle differences in: (1) muscle stiffness, (2) intramuscular fluid pressure, or (3) motor unit firing frequency.  相似文献   

5.

Purpose

To examine changes in hamstring muscle fatigue and central motor output during a 90-minute simulated soccer match, and the concomitant changes in hamstring maximal torque and rate of torque development.

Method

Eight amateur male soccer players performed a 90-minute simulated soccer match, with measures performed at the start of and every 15-minutes during each half. Maximal torque (Nm) and rate of torque development (RTD; Nm.s–1) were calculated from maximal isometric knee flexor contractions performed at 10° of flexion. Hamstring peripheral fatigue was assessed from changes in the size and shape of the resting twitch (RT). Hamstring central motor output was quantified from voluntary activation (%) and normalized biceps femoris (BF) and medial hamstrings (MH) electromyographic amplitudes (EMG/M).

Results

Maximal torque was reduced at 45-minutes by 7.6±9.4% (p<0.05). RTD in time intervals of 0–25, 0–50, and 0–75 ms post-contraction onset were reduced after 15-minutes in the first-half between 29.6 to 46.2% (p<0.05), and were further reduced at the end of the second-half (p<0.05). Maximal EMG/M was reduced for biceps femoris only concomitant to the time-course of reductions in maximal torque (p = 0.007). The rate of EMG rise for BF and MH was reduced in early time periods (0–75 ms) post-contraction onset (p<0.05). No changes were observed for the size and shape of the RT, indicating no hamstring peripheral fatigue.

Conclusion

Centrally mediated reductions in maximal torque and rate of torque development provide insight into factors that may explain hamstring injury risk during soccer. Of particular interest were early reductions during the first-half of hamstring rate of torque development, and the decline in maximal EMG/M of biceps femoris in the latter stages of the half. These are important findings that may help explain why the hamstrings are particularly vulnerable to strain injury during soccer.  相似文献   

6.
The purpose of this study was to examine the patterns for the mechanomyographic (MMG) and electromyographic (EMG) amplitude and mean power frequency (MPF) vs. torque relationships during submaximal to maximal isometric and isokinetic muscle actions. Seven men (mean +/- SD age, 22.4 +/- 1.3 years) volunteered to perform isometric and concentric isokinetic leg extension muscle actions at 20, 40, 60, 80, and 100% of maximal voluntary contraction (MVC) and peak torque (PT) on a Cybex II dynamometer. A piezoelectric MMG recording sensor was placed between bipolar surface EMG electrodes on the vastus medialis. Polynomial regression and separate 1-way repeated-measures analysis of variance were used to analyze the EMG amplitude, MMG amplitude, EMG MPF, and MMG MPF data for the isometric and isokinetic muscle actions. For the isometric muscle actions, EMG amplitude (R(2) = 0.999) and MMG MPF (R(2) = 0.946) increased to MVC, mean MMG amplitude increased to 60% MVC and then plateaued, and mean EMG MPF did not change (p > 0.05) across torque levels. For the isokinetic muscle actions, EMG amplitude (R(2) = 0.988) and MMG amplitude (R(2) = 0.933) increased to PT, but there were no significant mean changes with torque for EMG MPF or MMG MPF. The different torque-related responses for EMG and MMG amplitude and MPF may reflect differences in the motor control strategies that modulate torque production for isometric vs. dynamic muscle actions. These results support the findings of others and suggest that isometric torque production was modulated by a combination of recruitment and firing rate, whereas dynamic torque production was modulated primarily through recruitment.  相似文献   

7.
The purpose of the study was to examine the potential for using the mechanomyographic (MMG) signal as a biofeedback method to enhance muscular relaxation and to improve performance during forearm flexion repetitions to fatigue. Twelve adult (mean +/- SD; age: 22.0 +/- 1.1 years) moderately trained subjects (weight: 82.3 +/- 29.2 kg; height: 165.7 +/- 49.0 cm) were instructed to relax the biceps brachii muscle using MMG biofeedback (BIO) provided by viewing a computer screen graphically displaying the MMG signal and then without using MMG biofeedback (NOBIO). Electromyographic (EMG) and MMG signals were detected midway over the biceps brachii during the relaxation protocol. In subsequent visits to the laboratory, subjects performed as many repetitions as possible at 85% of 1 repetition maximum with BIO and NOBIO using the seated preacher curl exercise. Two-way (biofeedback x gender) mixed factorial analyses of variance revealed significantly (p < 0.05) lower MMG (mean +/- SEM; BIO = 0.6 +/- 0.1 mV; NOBIO = 1.1 +/- 0.2 mV) and EMG amplitudes (BIO = 6.6 +/- 0.6 microV; NOBIO = 9.4 +/- 1.4 microV) for BIO when subjects were instructed to relax the biceps brachii muscle. There was no significant difference in the number of forearm flexion repetitions performed for BIO (mean +/- SD; 7.9 +/- 0.4 reps) vs. NOBIO (8.1 +/- 0.6 reps). The results of the present study revealed that using MMG as a biofeedback technique can enhance the development of muscle relaxation, but is not useful in delaying fatigue during forearm flexion repetitions. Our results may have been influenced by a relatively short training phase designed to teach subjects to use the MMG signal as a biofeedback method. Future studies are needed to determine whether MMG biofeedback can be used for other purposes. If MMG is found to be useful as a biofeedback method, it has some distinct practical advantages over EMG that the strength and conditioning athlete and professional may find appealing.  相似文献   

8.
The purpose of this study was to compare a piezoelectric contact sensor with an accelerometer for measuring the mechanomyographic (MMG) signal from the biceps brachii during submaximal to maximal isokinetic and isometric forearm flexion muscle actions. Following determination of isokinetic peak torque (PT) and the isometric maximum voluntary contraction (MVC), 10 adults (mean+/-SD age=22.8+/-2.7yrs) performed randomly ordered, submaximal step muscle actions of the dominant forearm flexors in 20% increments from 20% to 80% PT and MVC. Surface MMG signals were recorded simultaneously from a contact sensor and an accelerometer placed over the belly of the biceps brachii muscle. During the isokinetic and isometric muscle actions, the contact sensor and accelerometer resulted in linear increases in normalized MMG amplitude with torque (r(2) range=0.84-0.97) but the linear slope of the normalized MMG amplitude versus isokinetic torque relationship for the accelerometer was less (p<0.10) than that of the contact sensor. There was no significant (p>0.05) relationship for normalized MMG mean power frequency (MPF, %max) versus isokinetic and isometric torque for the contact sensor, but the accelerometer demonstrated a quadratic (R(2)=0.94) or linear (r(2)=0.83) relationship for the isokinetic and isometric muscle actions, respectively. There were also a number of significant (p<0.05) mean differences between the contact sensor and accelerometer for normalized MMG amplitude or MPF values. These findings indicated that in some cases involving dynamic and isometric muscle actions, the contact sensor and accelerometer resulted in different torque-related responses that may affect the interpretation of the motor control strategies involved.  相似文献   

9.
The purpose of this study was to investigate the effect of elastic compression on muscle strength, electromyographic (EMG), and mechanomyographic (MMG) responses of quadriceps femoris during isometric and isokinetic contractions. Twelve participants performed 5 s isometric maximal voluntary contractions (MVC) and 25 consecutive and maximal isokinetic knee extensions at 60 and 300 °/s with no (control, CC), medium (MC), and high (HC) compression applied to the muscle. The EMG and MMG signals were collected simultaneously with muscle isometric and isokinetic strength data. The results showed that the elevated compression did not improve peak torque, peak power, average power, total work, and regression of torque in the isometric and isokinetic contractions. However, the root mean squared value of EMG in both HC and MC significantly decreased compared with CC at 60 and 300 °/s (p < 0.01). Furthermore, the EMG mean power frequency in HC was significantly higher than that in CC at 60 °/s (p < 0.05) whereas no significant compression effect was found in the MMG mean power frequency. These findings provide preliminary evidence suggesting that the increase in local compression pressure may effectively increase muscle efficiency and this might be beneficial in reducing muscle fatigue during concentric isokinetic muscle contractions.  相似文献   

10.
Objectives:This study aimed to examine the efficacy of isometric knee extension and flexion peak torque and rate of torque development (RTD) variables to distinguish starters from non-starters in collegiate female soccer players.Methods:Eleven starters (20±2 years) and 13 non-starters (19±1 years) performed three isometric maximal voluntary contractions of the knee extensors and flexors. Peak torque, peak RTD, and RTD at 0-100 (RTD100) and 0-200 (RTD200) ms were obtained from each contraction.Results:The starters produced significantly greater (P=0.002-0.015) knee extension and flexion peak RTD, RTD100, and RTD200 values than the non-starters. There were no significant differences (P>0.050) between the starters and non-starters for peak torque. Discriminant analysis revealed thresholds of 9.36, 7.98, and 6.97 Nm⋅s-1⋅kg-1 for knee extension RTD200 and knee flexion peak RTD and RTD100, respectively. These thresholds showed 81.8% sensitivity and 76.9 to 92.3% specificity for identifying playing group membership.Conclusions:Our findings indicate that RTD may be a better parameter than peak torque at differentiating between playing level in collegiate female soccer players. The discriminant analysis thresholds for the RTD variables demonstrated good sensitivity and specificity, and therefore, may be used as indices to identify players with a high degree of soccer playing ability.  相似文献   

11.
Objectives:The purpose of the present study was to compare the fatigue-induced changes in performance fatigability, bilateral deficit, and patterns of responses for the electromyographic (EMG) and mechanomyographic (MMG) amplitude (AMP) and mean power frequency (MPF), during unilateral and bilateral maximal, fatiguing leg extensions.Methods:Nine men (Mean±SD; age =21.9±2.4 yrs; height =181.8±11.9 cm; body mass =85.8±6.2 kg) volunteered to perform 50 consecutive maximal, bilateral (BL), unilateral dominant (DL), and unilateral non-dominant (NL) isokinetic leg extensions at 180°·s-1, on 3 separate days. Electromyographic and MMG signals from both vastus lateralis (VL) muscles were recorded. Repeated measures ANOVAs were utilized to examine mean differences in normalized force, EMG AMP, EMG MPF, MMG AMP, MMG MPF and the bilateral deficit.Results:The results demonstrated a Condition × Repetition interaction for normalized force (p=0.004, η2p=0.222) and EMG MPF (p=0.034, η2p=0.214) and main effects for Repetition for EMG AMP (p=0.019, η2p=0.231), MMG AMP (p<0.001, η2p=0.8550), MMG MPF (p=0.009, η2p=0.252), and the bilateral deficit (p<0.001, η2p=0.366).Conclusions:The findings demonstrated less performance fatigability during the BL than the unilateral tasks, likely due to a reduced relative intensity via interhemispheric inhibition that attenuated the development of excitation-contraction coupling failure during the BL task.  相似文献   

12.

Purpose

To examine quadriceps muscle fatigue and central motor output during fatiguing single joint exercise at 40% and 80% maximal torque output in resistance trained men.

Method

Ten resistance trained men performed fatiguing isometric knee extensor exercise at 40% and 80% of maximal torque output. Maximal torque, rate of torque development, and measures of central motor output and peripheral muscle fatigue were recorded at two matched volumes of exercise, and after a final contraction performed to exhaustion. Central motor output was quantified from changes in voluntary activation, normalized surface electromyograms (EMG), and V-waves. Quadriceps muscle fatigue was assessed from changes in the size and shape of the resting potentiated twitch (Q.pot.tw). Central motor output during the exercise protocols was estimated from EMG and interpolated twitches applied during the task (VAsub).

Results

Greater reductions in maximal torque and rate of torque development were observed during the 40% protocol (p<0.05). Maximal central motor output did not change for either protocol. For the 40% protocol reductions from pre-exercise in rate and amplitude variables calculated from the Q.pot.tw between 66.2 to 70.8% (p<0.001) exceeded those observed during the 80% protocol (p<0.01). V-waves only declined during the 80% protocol between 56.8 ± 35.8% to 53.6 ± 37.4% (p<0.05). At the end of the final 80% contraction VAsub had increased from 91.2 ± 6.2% to 94.9 ± 4.7% (p = 0.005), but a greater increase was observed during the 40% contraction where VAsub had increased from 67.1 ± 6.1% to 88.9 ± 9.6% (p<0.001).

Conclusion

Maximal central motor output in resistance trained men is well preserved despite varying levels of peripheral muscle fatigue. Upregulated central motor output during the 40% contraction protocol appeared to elicit greater peripheral fatigue. V-waves declines during the 80% protocol suggest intensity dependent modulation of the Ia afferent pathway.  相似文献   

13.
Objectives:To examine changes in muscle thickness (MT), soreness (SOR), and isometric torque (ISO) following exercise with pulsed direct current (Neubie) or traditional high-load (TRAD) exercise.Methods:Thirty-two participants had SOR, MT, and ISO measured before, immediately after, and 24 and 48h following TRAD and Neubie. Rating of perceived exertion (RPE) and discomfort were also measured. Results are displayed as means(SD).Results:For MT, there was a condition x time interaction (p<0.001). For Neubie, MT increased pre [3.7(0.7)cm] to post [3.9(0.8) cm, p<0.001] and remained elevated at 24h. For TRAD, MT increased pre [3.7(0.6)cm] to post [4.0 (0.7)cm, p<0.001] and remained up to 48h. Greater values were observed for TRAD post-exercise. For ISO, both conditions decreased up to 48h. TRAD demonstrated a greater change post exercise (p<0.001). For SOR, both conditions increased up to 48h. Neubie demonstrated greater SOR at 48h (p=0.007). RPE was higher for all sets in TRAD [Mean across sets=16.0(1.9) vs. 13.5(2), p<0.001]. Discomfort was higher in all sets for Neubie [Mean across sets=5.8(1.5)vs. 4.5(2.0), p<0.05].Conclusions:Both conditions showed increased SOR, and decreased ISO for up to 48h, with MT increased for up to 24h. MT remained elevated in TRAD at 48h. Neubie training might be effective for individuals who are looking to experience lower RPE responses during exercise.  相似文献   

14.
The purpose of this study was to examine the strength, electromyographic (EMG), and mechanomyographic (MMG) responses after workouts designed to elicit fatigue and muscle damage vs. only fatigue. Thirteen men (mean ± SD age = 23.7 ± 2.2 years) performed 6 sets of 10 maximal concentric isokinetic (CONexercise) or eccentric isokinetic (ECCexercise) muscle actions of the dominant forearm flexors on 2 separate days. Before (PRE) and after (POST) these workouts, peak torque (PT), surface EMG, and MMG signals were measured during maximal concentric isokinetic, eccentric isokinetic, and isometric muscle actions of the forearm flexors. The subjects also visited the laboratory for a control (CTL) visit with quiet resting between the PRE and POST measurements, rather than performing the CONexercise or ECCexercise. The results showed that there were significant 26 and 25% decreases in PT after the CONexercise and ECCexercise, respectively, and these decreases were statistically equivalent for the concentric, eccentric, and isometric muscle actions. There were also 19 and 23% reductions in normalized EMG amplitude after the CONexercise and ECCexercise, respectively, but no changes in EMG mean frequency (MNF), MMG amplitude, or MMG MNF. These findings demonstrated a neural component(s) to the strength decrement after CONexercise and ECCexercise. It is possible that after these 2 types of exercise, activation of free nerve endings that are sensitive to muscle damage and pH changes resulted in inhibition of alpha motor neurons, causing decreased muscle activation and torque. These findings suggest that training programs designed to minimize strength loss during competition should consider the fact that at least some of this loss is because of neural factors.  相似文献   

15.
We aimed to investigate the impact of time on fine-wire (fw) electromyography (EMG) signal amplitude, and to determine whether any attenuation is confounded by task type. Twenty healthy participants were instrumented with fw and surface (s) EMG electrodes at the biceps brachii bilaterally. Participants held a weight statically with one arm and with the other arm either repeated the same task following a maximum voluntary contraction (MVC) or repeated dynamic elbow flexion/extension contractions. Each task was repeated for 30 s every five minutes over two hours. EMG amplitude was smoothed and normalized to time = 0. Stable median power frequency of the s-EMG ruled out the confounding influence of fatigue. Repeated-measures ANCOVAs determined the effect of electrode type and time (covariate) on EMG amplitude and the confounding impact of task type. During the isometric protocol, fw-EMG amplitude reduced over time (p = 0.002), while s-EMG amplitude (p = 0.895) and MPF (p > 0.05) did not change. Fw-EMG amplitude attenuated faster during the dynamic than the isometric protocol (p = 0.008) and there was evidence that the MVC preceding the isometric protocol impacted the rate of decline (p = 0.001). We conclude that systematic signal attenuation of fw-EMG occurs over time and is more pronounced during dynamic tasks.  相似文献   

16.

Purpose

This study aimed: i) to examine the relationship between the magnitude of cross-talk in mechanomyographic (MMG) signals generated by the extensor digitorum (ED), extensor carpi ulnaris (ECU), and flexor carpi ulnaris (FCU) muscles with the sub-maximal to maximal isometric grip force, and with the anthropometric parameters of the forearm, and ii) to quantify the distribution of the cross-talk in the MMG signal to determine if it appears due to the signal component of intramuscular pressure waves produced by the muscle fibers geometrical changes or due to the limb tremor.

Methods

Twenty, right-handed healthy men (mean ± SD: age  = 26.7±3.83 y; height  = 174.47±6.3 cm; mass  = 72.79±14.36 kg) performed isometric muscle actions in 20% increment from 20% to 100% of the maximum voluntary isometric contraction (MVIC). During each muscle action, MMG signals generated by each muscle were detected using three separate accelerometers. The peak cross-correlations were used to quantify the cross-talk between two muscles.

Results

The magnitude of cross-talk in the MMG signals among the muscle groups ranged from, R2x, y = 2.45–62.28%. Linear regression analysis showed that the magnitude of cross-talk increased linearly (r2 = 0.857–0.90) with the levels of grip force for all the muscle groups. The amount of cross-talk showed weak positive and negative correlations (r2 = 0.016–0.216) with the circumference and length of the forearm respectively, between the muscles at 100% MVIC. The cross-talk values significantly differed among the MMG signals due to: limb tremor (MMGTF), slow firing motor unit fibers (MMGSF) and fast firing motor unit fibers (MMGFF) between the muscles at 100% MVIC (p<0.05, η 2 = 0.47–0.80).

Significance

The results of this study may be used to improve our understanding of the mechanics of the forearm muscles during different levels of the grip force.  相似文献   

17.
The objective of this study was to examine the effect of joint angle on the electromyogram (EMG) and mechanomyogram (MMG) during maximal voluntary contraction (MVC). Eight subjects performed maximal isometric plantar flexor torque productions at varying knee and/or ankle angles. Maximal voluntary torque, EMG, and MMG from the soleus (Sol), medial (MG) and lateral gastrocnemius (LG) muscles were measured at different joint angles. At varying knee angles, the root mean squared (rms) MMG amplitude of the MG and LG increased with knee joint extension from 60 degrees to 180 degrees (full extension) in steps of 30 degrees, whereas that of the Sol was constant. At varying ankle angles, the rms-MMG of all muscles (Sol, MG, and LG) decreased with torque as ankle joint extending from 80 degrees (10 degrees dorsiflexion position) to 120 degrees (30 degrees plantar flexion position) in steps of 10 degrees. In each case, changes in the rms-MMG of the three muscles were almost parallel to those in torque. In contrast, there were no significant differences in the rms-EMG of all muscles among all joint angles. Our data suggest that the MMG amplitudes recorded from individual muscles during MVCs can represent relative torque-angle relationships that cannot be represented by the EMG signals.  相似文献   

18.
The purpose of the present study was to examine the patterns of responses for torque, electromyographic (EMG) amplitude, EMG mean power frequency (MPF), mechanomyographic (MMG) amplitude, and MMG MPF across 30 repeated maximal isometric (ISO) and concentric (CON) muscle actions of the leg extensors. Twelve female subjects (21.1 ± 1.4 yrs; 63.3 ± 7.4 kg) performed ISO and CON fatigue protocols with EMG and MMG signals recorded from the vastus lateralis. The relationships for torque, EMG amplitude, EMG MPF, MMG amplitude, and MMG MPF versus repetition number were examined using polynomial regression. The results indicated there were decreases (p < 0.05) across the ISO muscle actions for torque (r2 = 0.95), EMG amplitude (R2 = 0.44), EMG MPF (r2 = 0.62), and MMG MPF (r2 = 0.48), but no change in MMG amplitude (r2 = 0.07). In addition, there were decreases across the CON muscle actions for torque (R2 = 0.97), EMG amplitude (R2 = 0.46), EMG MPF (R2 = 0.86), MMG amplitude (R2 = 0.44), and MMG MPF (R2 = 0.80). Thus, the current findings suggested that the mechanisms of fatigue and motor control strategies used to modulate torque production were similar between maximal ISO and CON muscle actions.  相似文献   

19.
The purpose of this investigation was to determine the effect of hyperhydration on the electromyographic (EMG) and mechanomyographic (MMG) responses during isometric and isokinetic muscle actions of the biceps brachii. Eight (22.1 +/- 1.8 years, 79.5 +/- 22.8 kg) subjects were tested for maximal isometric, submaximal isometric, and maximal concentric isokinetic muscle strength in either a control (C) or hyperhydrated (H) state induced by glycerol ingestion while the EMG and MMG signals were recorded. Although fluid retention was significantly greater during the H protocol, the analyses indicated no change in torque, EMG amplitude, EMG mean power frequency (MPF), MMG amplitude, or MMG MPF with hyperhydration. These results indicated that glycerol-induced fluid retention does not affect the torque-producing capabilities of a muscle, the impulses (EMG) going to a muscle, or muscular vibrations (MMG). It has been suggested that EMG and MMG can be used as direct electrical/mechanical monitoring, which could be presented to trainers and athletes; however, before determining the utility of these signals, the MMG and EMG responses should be examined under a variety of conditions such as in the present study.  相似文献   

20.
IntroductionThe purpose of this study was to examine possible correlations between skinfold thicknesses and the a terms from the log-transformed electromyographic (EMGRMS) and mechanomyographic amplitude (MMGRMS)-force relationships, EMG M-Waves, and MMG gross lateral movements (GLM).MethodsForty healthy subjects performed a 6-s isometric ramp contraction from 5% to 85% of their maximal voluntary contraction with EMG and MMG sensors placed on the vastus lateralis (VL) and rectus femoris (RF). A single electrical stimulus was applied to the femoral nerve to record the EMG M-waves and MMG GLMs. Skinfold thickness was assessed at the site of each electrode. Pearson’s product correlation coefficients were calculated comparing skinfold thicknesses with the a terms from the log-transformed EMGRMS-and MMGRMS-force relationships, EMG M-waves, and MMG GLMs.ResultsThere were no significant cor1relations (p > 0.05) between the a terms and skinfold thicknesses for the RF and VL from the EMGRMS and MMGRMS-force relationships. However, there were significant correlations (p < 0.05) between skinfold thicknesses and the EMG M-waves and MMG GLMs for the RF (r = −0.521, −0.376) and VL (r = −0.479, −0.484).DiscussionRelationships were only present between skinfold thickness and the amplitudes of the EMG and MMG signals during the non-voluntary muscle actions.  相似文献   