首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Plasma exchanges were combined with human factor VIII concentrate therapy in the treatment of major bleeding episodes in five patients with haemophilia A and factor VIII inhibitors. All patients had a good clinical response to combined treatment. Inhibitor levels showed satisfactory falls before rapid secondary increases of inhibitor levels took place. A sixth patient with von Willebrand''s disease and a factor VIII clotting activity inhibitor was successfully prepared for operation using plasma exchange. Postoperative haemostasis and healing were normal. In two patients the plasma exchanges were relatively more effective than the administered human factor VIII in reducing the levels of factor VIII inhibitor. Combined plasma exchange and human factor VIII treatment may offer a rapidly effective means of reducing factor VIII inhibitor levels in this group of patients, together with significant saving of costs.  相似文献   

2.
Environmental samples analyzed by quantitative PCR (qPCR) are subject to interference by inhibitors present in the environment being sampled. A controlled determination of the effect of inhibitors associated with sampling indoor air and the ability of internal standard controls to detect inhibition was carried out by filter collection of air samples followed by spiking of the filters with green fluorescent protein-expressing Aspergillus fumigatus conidia. Microscopic conidial counts were compared with qPCR results and correlated with levels of particulate matter and viable airborne microorganisms. Our data showed that PCR can be inhibited by masses of particulate matter as low as 50 μg and that the amount of inhibition was positively correlated with the mass of particulate (r = 0.75) and the number of non-filamentous organisms (r = 0.73). The use of internal standard DNA identified the presence of inhibitors and indicated the need for additional sample processing or qualification of sample results.  相似文献   

3.
The exposure of individuals to environmental tobacco smoke (ETS) is of increasing public health concern because epidemiological studies have associated passive smoking with increased risk of a variety of adverse health effects among non-smokers including lung cancer. As a way to measure individual exposure to the mutagenic compounds in the complex mixture of ETS, we used a sensitive Salmonella/microsome micro pre-incubation (microsuspension) assay to detect mutagenicity of particulate matter collected on filters from low volume (1.7 1/min flow rate) personal sampling pumps. Airborne nicotine was collected concurrently as a marker for ETS exposure. In pilot-field studies, individual exposure to ETS was measured in two separate indoor environments in which smokers were present: a gambling casino and a bingo parlor. Total suspended particulate matter (TSP) was collected on filters worn near the breathing zone of non-smoking individuals. Sampling times ranged from 40 min to 6 h. All extracts of filters had detectable levels of mutagenic activity (TA98, +S9) resulting in airborne mutagenic activity concentrations of 500-5000 rev/m3. The mutagenic activity of the filters from the casino and bingo parlors was significantly correlated with total particulate matter per filters (n = 12; Rho = 0.85, p less than 0.01) and with airborne nicotine per filter (n = 12; Rho = 0.95, p less than 0.01). The microsuspension assay was sufficiently sensitive to detect the mutagens associated with extracts of particulate matter from low volume samples (0.2-0.6 m3) in these indoor environments over a relatively short sampling time, and could be useful in studies of personal exposure to the mutagens in environmental tobacco smoke. Further, airborne nicotine concentrations were highly correlated with airborne mutagenicity and the mutagenic activity associated with ETS could therefore be estimated by the concentrations of nicotine.  相似文献   

4.
Brydsten  Lars 《Hydrobiologia》1992,235(1):71-83
Material transported by the Öre River in northern Sweden is all deposited within the estuary which means that resuspension is necessary for the transport of particles out of the estuary. Wave-induced sediment resuspension in the estuary was studied by monitoring the distribution of suspended particles during a resuspension-redeposition cycle. The particle concentration in the water mass was measured with a light scattering probe, calibrated by comparison with the amount of particles collected on a filter.After a long period with calm weather and a low river input less than 100 tonne of suspended particulate matter was present in the estuary. However, during a period with stormy conditions significant resuspension of sediment particles occurred within the estuary. Two days after the storm approximately 1125 tonne of suspended particulate matter was found in the estuary. Most (61%) of the suspended matter was found in the deepest third of the water column, although up to 17% was present in the top third of the water column. The total load of particulate matter in the water column remained constant until day four after the storm, but a significant redistribution of the particulate matter occurred both in the vertical and horizontal directions. Nine days after the storm, a significant amount of particles (c. 350 tonnes) was still in suspension.  相似文献   

5.
A contemporary PM2.5 (particulate matter smaller than 2.5 Μm aerodynamic diameter) aerosol material from an urban site has been collected for the production of a new standard reference material that will be made available for the development of new PM2.5 air quality standards. Air particulate matter corresponding to the PM2.5 fraction was collected at an established Environmental Protection Agency monitoring site in Baltimore, Maryland. The air-sampling system that has been constructed for this collection separates fine particles with a cyclone separator and deposits them onto an array of Teflon membrane filters. The fine air particulate material is removed by ultrasonication or by mechanical means and collected for further preparation of standards. The composition of the collected PM2.5 aerosol, as well as the composition of the deposited PM2.5 aerosol, are determined by instrumental nuclear activation analysis and other techniques.  相似文献   

6.
Enhancement of the diaminobenzidine (DAB) reaction product for light photomicroscopy was investigated using commercially available glass interference filters FITC-495, BG38, and BG12. The oxidized DAB transmission curve between 400-700 nm revealed a broad peak extending mostly through the yellow to red portions of the visible light spectrum, indicating that no single color predominates. Absorption spectra from the interference filters showed that FITC-495 gave total absorbance from 495-650 nm, with a smaller peak at 675 nm; BG38 transmitted at least a percentage of every wavelength up to 700 nm, whereas BG12 absorbed all light above 490 nm. To determine whether these filters could photographically increase DAB reaction product contrast, photographs were taken of corneal endothelial cells 24 hr after freeze injury. At this time, these cells demonstrate increased levels of laminin, as revealed by immunoperoxidase cytochemistry. When photography was performed using either no filter or a standard green filter, DAB contrast relative to background was minimal. However, when photographs were made using either the FITC-495 or the BG12 filter, DAB contrast increased sharply, although background density increased in the former case and decreased greatly in the latter. BG38 by itself did not increase DAB contrast. However, when used in combination with FITC-495 good DAB contrast was achieved and background density was lower than that seen using FITC-495 alone. Therefore, selective interference filters can photographically increase DAB contrast for studies using immunoperoxidase cytochemistry.  相似文献   

7.
Centrifugal filters for SW 25.1 and 50.1 swinging-bucket ultracentrifuge rotors have been tested up to the maximum speeds allowed, 90,000 and 300,000g, respectively. The filters are 1 and 0.5 in. in diameter and accept standard 25-mm polycarbonate filter membranes. The filter membranes are both cup-shaped to prevent loss of particulates to the support materials of the filters. The filter for the SW 25.1 rotor can take 0.75 ml and that of the 50.1 head 0.5 ml. The fluid retained after centrifuging consists of the fluid on the filter membrane and in its pores and that retained by the material filtered. The calculated volume of the pores of the 0.2-μm filter was 0.46 μl. Total liquid retentions of about 0.8 μl have been achieved with both filters using a particulate concentration of 0.5 mg/ml.  相似文献   

8.
Environmental DNA (eDNA) is a promising tool for rapid and noninvasive biodiversity monitoring. eDNA density is low in environmental samples, and a capture method, such as filtration, is often required to concentrate eDNA for downstream analyses. In this study, six treatments, with differing filter types and pore sizes for eDNA capture, were compared for their efficiency and accuracy to assess fish community structure with known fish abundance and biomass via eDNA metabarcoding. Our results showed that different filters (with the exception of 20‐μm large‐pore filters) were broadly consistent in their DNA capture ability. The 0.45‐μm filters performed the best in terms of total DNA yield, probability of species detection, repeatability within pond and consistency between ponds. However performance of 0.45‐μm filters was only marginally better than for 0.8‐μm filters, while filtration time was significantly longer. Given this trade‐off, the 0.8‐μm filter is the optimal pore size of membrane filter for turbid, eutrophic and high fish density ponds analysed here. The 0.45‐μm Sterivex enclosed filters performed reasonably well and are suitable in situations where on‐site filtration is required. Finally, prefilters are applied only if absolutely essential for reducing the filtration time or increasing the throughput volume of the capture filters. In summary, we found encouraging similarity in the results obtained from different filtration methods, but the optimal pore size of filter or filter type might strongly depend on the water type under study.  相似文献   

9.
A multiple filtration device for glass fibre filters   总被引:1,自引:1,他引:0  
A practical multiple filter holder is described for collection of particles on glass fibre filters. The device utilizes large diameter discs and the ends of individual filter tubes compress against the filter so that, after filtration, the separate filtering areas can easily be taken from the large disc with forceps. If analyses of collected particulate matter are to be made at a later time, the filtering areas are left attached to the original filter. Precise volumes of water can be filtered by attaching volumetric pipettes to individual filter tubes.  相似文献   

10.
Two secondary standards for use in routine assays of Factor VIII in therapeutic concentrates and in patients, plasmas, respectively, have been established in a multicenter collaborative study. In order to assess the effect of the adoption of these preparations as common Secondary Standards a comparative assay has been performed: one sample of a Factor VIII concentrate of intermediate purity and one plasma sample have been tested in two laboratories for Factor VIII:C activity using as reference, among others, the common working standard. Analysis of the results shows that with the plasma sample the differences of the estimates obtained with any of the references in our two laboratories were not statistically significant (P greater than 0.3), while with the concentrate sample the differences were always statistically significant (P less than 0.005). The study shows that the adoption of common working standards (besides the uniformity in assay method, reagents and basic equipment) is not sufficient to eliminate interlaboratory variation in the measurement of Factor VIII:C.  相似文献   

11.
Wang Z  Banks C 《Biodegradation》2006,17(5):415-422
The research examines the potential for bio-clogging in filter packs containing fine sand of the type typically used in extraction wells for pumping leachates containing fine particulate matter, such as cement kiln dust (CKD). Three filter media with different particle sizes were used: 1.7–4.75, 0.35–1.0, and 0.235–0.45 mm. Each sand filter was tested using a leachate recirculating column reactor with a free drainage layer, on top of which was placed the filtration medium which was kept saturated and at a positive hydrostatic head by a 2-l reservoir of leachate. The leachate was collected from a landfill site that had been used for the co-disposal of municipal solid waste (MSW) and CKD. The leachate used was filtered by passing through a Whatman GFA filter paper before being added to the reactors in order to eliminate as far as possible the non-biological clogging which might have resulted from the introduction of particulate matter in the form of CKD. The filters and a control experiment were run under anaerobic conditions at 35 °C. The bio-clogging potential was observed by taking differential manometer readings from manometers located in the drainage and reservoir sections of the reactor. No clogging was detected using the coarser of the filter media, but there was some clogging when a finer filter medium was used. Head space gas analysis indicated that methanogenic activity was inhibited and analysis of the liquid phase indicated that the microbial process responsible for removal of chemical oxygen demand (COD) was principally one of sulphate reduction.  相似文献   

12.
Since 1992, the International Atomic Energy Agency (IAEA) has been promoting studies of air pollution using a standard design of air sampler that provides separation on filters into two size fractions with cutoffs of 2.5 and 10 Μm (approximately). These are the size ranges presently considered to have the most important health consequences. Such filter samples are highly amenable to analysis using nuclear and related techniques. After reviewing some of the health effects of airborne particulate matter and current air quality standards and guidelines, this article provides an overview of current and recent IAEA programs in this area, which involve collaborative activities with participants in more than 40 countries.  相似文献   

13.
Virus‐removal filtration technology is commonly used in the manufacturing process for biologics to remove potential viral contaminants. Virus‐removal filters designed for retaining parvovirus, one of the smallest mammalian viruses, are considered an industry standard as they can effectively remove broad ranges of viruses. It has long been observed that the performance of virus filters can be influenced by virus preparations used in the laboratory scale studies (PDA, 2010 ). However, it remains unclear exactly what quality attributes of virus preparations are critical or indicative of virus filter performance as measured by effectiveness of virus removal and filter capacity consistency. In an attempt to better understand the relationship between virus preparation and virus filter performance, we have systematically prepared and analyzed different grades of parvovirus with different purity levels and compared their performance profiles on Viresolve® Pro parvovirus filters using four different molecules. Virus preparations used in the studies were characterized using various methods to measure DNA and protein content as well as the hydrodynamic diameter of virus particles. Our results indicate that the performance of Viresolve® Pro filters can be significantly impacted depending on the purity of the virus preparations used in the spike and recovery studies. More importantly, we have demonstrated that the purity of virus preparations is directly correlated to the measurable biochemical and biophysical properties of the virus preparations such as DNA and protein content and monodispersal status, thus making it possible to significantly improve the consistency and predictability of the virus filter performance during process step validations. Biotechnol. Bioeng. 2013; 110: 229–239. © 2012 Wiley Periodicals, Inc.  相似文献   

14.
Summary Organ cultures of hearts maintained in media sterilized by filtration through different types of commercially available disposable membrane filter units displayed different beating rates and survival patterns. Media filtered through two different filter units sold by one company were severely toxic. Prewashing the filters removed most if not all of the toxins. This work was supported by grants from the National Heart, Lung and Blood Institute (HL14706) and the Moss Heart Fund.  相似文献   

15.
Six hemophilia patients previously seronegative for human immunodeficiency virus (HIV) seroconverted between September 1986 and September 1987. None had risk factors for HIV infection other than hemophilia. We compared the factor concentrates received by these patients with the concentrates received by 10 seronegative hemophilia patients. A statistically significant association was observed between seropositivity and the receipt of two lots of Factor VIII produced from the same plasma pool (odds ratio 77, p = 0.0014); five of the six case subjects but none of the control subjects had received concentrate from one of the two lots. Available evidence suggests that the sixth case subject had also received concentrate from an implicated lot. Symptoms including rash and fever were reported in five cases within 6 weeks after the implicated concentrate had been given. The implicated lots were produced from plasma from paid donors that had been screened and then heated at 60 degrees C for 30 hours in the lyophilized state. Subsequent to our investigation all concentrate produced by this process was removed from distribution.  相似文献   

16.
SUMMARY

Water samples were collected from fourteen sampling points along the Hunyani River system and subjected to various filtration treatments involving glass fibre filters and 1,2 and 0,45 pm membrane filters. Chemical analyses of the filtered waters showed that nitrogen, phosphorus and iron were lost by different filtration treatments. Filtration by membrane filters led to a reduction of algal growth potential as demonstrated by algal bioassays using Selanastrwn capricornutum Printz as the test alga.

Algal bioassays showed that biologically available phosphorus was primarily removed by the 1,2 μm membrane filter while biologically available nitrogen and iron was principally lost by filtration through the 0,25 μm membrane filter. A refined algal bioassay designed to determine the identity of limiting micronutrients found that all essential micronutrients were affected by membrane filtration.  相似文献   

17.
The current knowledge about the microbial communities associated with airborne particulate matter, particularly in urban areas, is limited. This study aims to fill this gap by describing the microbial community associated with coarse (PM10) and fine (PM2.5) particulate matter using pyrosequencing. Particulate matter was sampled on Teflon filters over 3 months in summer and 3 months in winter in Milan (Italy), and the hypervariable V3 region of the gene 16S rRNA amplified from the DNA extracted from the filters. The results showed large seasonal variations in the microbial communities, with plant-associated bacteria dominating in summer and spore-forming bacteria in winter. Bacterial communities from PM10 and PM2.5 were also found to differ from each other by season. In all samples, a high species richness, comparable with that of soils, but a low evenness was found. The results suggest that not only can the sources of the particulate influence the presence of specific bacterial groups but also that environmental factors and stresses can shape the bacterial community.  相似文献   

18.
The asparagine-linked sugar chains of blood coagulation factor VIII preparations purified from human plasma of blood group A donors and from the culture media of recombinant BHK cells were released as oligosaccharides by hydrazinolysis. These sugar chains were converted to radioactive oligosaccharides by reduction with sodium borotritide and separated into neutral and acidic fractions by paper electrophoresis. Most of the acidic oligosaccharides were converted to neutral ones by sialidase digestion, indicating that they are sialyl derivatives. The neutral and sialidase-treated acidic oligosaccharides were fractionated by serial chromatography on immobilized lectin columns and Bio-Gel P-4 column. Structural study of each oligosaccharide by sequential exo- and endoglycosidase digestion and by methylation analysis revealed that both factor VIII preparations contain mainly high mannose-type and bi-, tri-, and tetra-antennary complex-type sugar chains. Some of the biantennary complex-type sugar chains from human plasma factor VIII contain blood group A and/or H determinant, while those from recombinant product do not. Some of the bi-, tri- and tetra-antennary complex-type sugar chains of the recombinant factor VIII contain the Gal alpha 1----3Gal group. A small number of the triantennary complex-type sugar chains from both preparations was found to contain the Gal beta 1----4(Fuc alpha 1----3)GlcNAc beta 1----4 (Gal beta 1----4GlcNAc beta 1----2)Man group. Studies of pharmacokinetic parameters of the recombinant factor VIII infused into baboons revealed that its half-life in blood circulation is similar to that of plasma derived factor VIII, suggesting that the oligosaccharide structural differences between them do not affect the fate of factor VIII in vivo.  相似文献   

19.
Neural tissues from adult, castrated male guinea pigs were examined for their capability to concentrate and metabolize [1,2-3H]testosterone (T) and [1,2-3H]dihydrotestosterone (DHT), both in vitro and in vivo. In vitro uptake of DHT and T was greater in the hypothalamus and anterior pituitary than in the cerebral cortex. With DHT as the substrate, the 800×g particulate concentration of this compound was highest in the hypothalamus, although in this tissue, particulate concentration was less than that of the cytoplasm. In the cerebral cortex 5α-androstane-3,17-dione was the most abundant metabolite, whereas 5α-androstane-3,17-dione, 5α-androstane-3α,17β-diol, and 5α-androstane-3β,17β-diol were all present in equivalent amounts in the hypothalamus and pituitary. Incubation with T resulted in the formation of DHT, 4-androstane-3,17-dione, and a compound with the mobility of 5α-(or 5β-)androstane-3,17-7-dione. The radioactivity associated with DHT was the most prevalent in the pituitary (1.3%), and least prevalent in the cerebral cortex (0.6%), and in all cases cytoplasmic concentration of this compound exceeded the concentration in the particulate fraction. Recrystallization failed to confirm the presence of estradiol-17β. Although there were no apparent tissue differences in the uptake of DHT or T 1 hour after their injection, intracellular distribution varied. In all tissues examined, that percentage of total radioactivity attributable to DHT was greatest in the 800×g particulate preparations, particularly in the hypothalamus. Thus neural tissues in the guinea pig, as in other species, exhibit differential uptake and metabolism of androgen through which physiological and behavioral effects may be mediated.  相似文献   

20.
Factor VIII is a multidomain protein composed of A1, A2, B, A3, C1, and C2 domains. Deficiency or dysfunction of factor VIII causes hemophilia A, a bleeding disorder. Administration of exogenous recombinant factor VIII as a replacement leads to development of inhibitory antibodies against factor VIII in 15-30% of hemophilia A patients. Hence, less immunogenic preparations of factor VIII are highly desirable. Inhibitory antibodies against factor VIII are mainly directed against immunodominant epitopes in C2, A3, and A2 domains. Further, several universal epitopes for CD4+ T-cells have been identified within the C2 domain. The C2 domain is also known to interact specifically with phosphatidylserine-rich lipid vesicles. Here, we have investigated the hypothesis that complexation of O-phospho-l-serine, the head group of phosphatidylserine, with the C2 domain can reduce the overall immunogenicity of factor VIII. The biophysical (circular dichroism and fluorescence) and biochemical studies (ELISA and size exclusion chromatography) showed that O-phospho-l-serine binds to the phospholipid-binding region in the C2 domain, and this interaction causes subtle changes in the tertiary structure of the protein. O-Phospho-l-serine also prevented aggregation of the protein under thermal stress. The immunogenicity of the factor VIII-O-phospho-l-serine complex was evaluated in hemophilia A mice. The total and inhibitory antibody titers were lower for factor VIII-O-phospho-l-serine complex compared with factor VIII alone. Moreover, factor VIII administered as a complex with O-phospho-l-serine retained in vivo activity in hemophilia A mice. Our results suggest that factor VIII-O-phospho-l-serine complex may be beneficial to increase the physical stability and reduce immunogenicity of recombinant factor VIII preparations.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号